Tender For Provision Of 02 X Single Jcos Living Accommodation (Otm) And Certain Other Sanctioned Work At Faridkot Mil Stn

BOQ

Name of Work:- PROVN OF 02 x SINGLE JCOs LIVING ACCN (OTM) AND CERTAIN OTHER SANCTIONED WORK AT FARIDKOT MIL STN
Sl. No. Item Description
1Excavating in trenches n exc 1.5 m in depth in any type of soil; for foundation, etc. and getting out including baling/pumping /dewatering(if required) of water complete all as specified and directed by Engr-In-Charge.
2Returning, filling in including spreading, leveling watering and well ramming in layers not exceeding 25cm complete all as specified and directed by Engr-In-Charge.
3Spreading and levelling in layers n.exc 25cm thick and well ramming including watering as required under floors; all as directed. (in floor with available earth from excavation approved by Engr-in-Charge.
4Removing excavated material exc 50 m and not exceeding 250 m and depositing where directed.
5M&L for PCC 1:4:8 type D2 40mm stone aggregate filling mass concrete in foundation complete all as specified and directed by Engr-In-Charge.
6Material and labour for providing Reinforced Cement Concrete (Design Mix) M-30 using 20 mm graded aggregate as in foundation including rafts, footings, foundation beams, plinth beams, bases of columns etc complete all as specified and directed by Engr-In-Charge.
7Material and labour for providing Reinforced Cement Concrete (Design Mix) M-30 using 20 mm graded aggregate as in Columns, pillars, piers, posts and struts complete all as specified and directed by Engr-In-Charge.
8Material and labour for providing Reinforced Cement Concrete (Design Mix) M-30 using 20 mm graded aggregate as in beams, cantilever, chajja,lintels over 1.5 m complete all as specified and directed by Engr-In-Charge.
9Material and labour for providing Reinforced Cement Concrete (Design Mix) M-30 using 20 mm graded aggregate as in slabs supported on walls, beams and columns in floor, roof, landing, balcknies, conopies, decks, slab and in shelves and like complete all as specified and directed by Engr-In-Charge.
10M & L Formwork to sides of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits (if any) of foundation and plinth beams; and similar work; rough finished vertical or to batter complete all as specified and directed by Engr-In-Charge.
11M & L Formwork to sides of pillars, posts, struts, piers, columns and stanchions rough finished vertical or to batter complete all as specified and directed by Engr-In-Charge.
12M & L formwork to sides and soffits of floor or roof beams, beam hunching, girders, lintels, cantlievers, shelves including supports, etc for rough finished flat surfaces of concrete complete all as specified and directed by Engr-In-Charge.
13M & L formwork to soffits of suspended slabs such as roof slabs, floor slabs, la ndings and similar work; not exceeding 200 mm thick (Horizontal or slopping) for rough finished flat surfaces of concrete complete all as specified and directed by Engr-In-Charge.
14Material and labour for 10 mm dia and over TMT bars, cut to length bend to shape as required including cranking, hooking etc and binding with and including mild steel wire (annealed) not less than 0.9 mm dia complete all as specified and directed by Engr-In-Charge.
15Material and labour for 5 mm dia and over upto and including 10mm dia in stirrups, spacers and binders TMT bars, cut to length bend to shape as required including cranking, hooking etc and binding with and including mild steel wire (annealed) not less than 0.9 mm dia complete all as specified and directed by Engr-In-Charge.
16M&L for hard core of broken brick of guage n.exc 63mm deposited spread and levelled in layer n.exc 15cm thick watered and well rammed to true surfaces as s complete all as specified and directed by Engr-In-Charge.
17Material and labour for providing 75 mm thick cement concrete (1:3:6) type C2 using 40mm graded aggregate as in plinth protection surfaces even and smooth without using extra cement including provision of construction joints complete all as specified and directed by Engr-In-Charge.
18M & L Forming Contraction (Dummy) joints 65mm deep x 10mm wide, filled with sealing compound grade A complete all as specified and directed by Engr-In-Charge.
19M & L Cement concrete 100 mm thick type D-2, 1:4:8 (40mm graded aggregate) as in sub-floors, sub bases, floors and pavings, etc complete all as specified and directed by Engr-In-Charge.
20S&F Virified Ceramic tiles 8-9 mm thick (square/ rectangular) polished, area of each tilesnot exceeding 0.36 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match including 15mm thick screed bed or bedding layer CM 1:4 for laying finishes,complete all as specified as directed by Engr-in- Charge
21M& L Non - skid Ceramic tiles 7 to 8 mm thick (square/ rectangular) area of each tile exceeding 0.11 sqm but not exceeding 0.18 sqm, in floors etc. set and jointed inneat cement slurry and pointed in white or coloured cement to match including 15mm thick screed bed or bedding layer CM 1:4 for laying finishes,complete all as specified as directed by Engr-in- Charge
22M & L brick work with fly ash bricks, straight or curved on plan exceeding 6 metre mean radius built in CM 1:6 complete all as specified and directed by Engr-In-Charge.
23Rendering 15mm thick in cement mortar 1:4 on any face of brick walls or concrete surfaces, finished even and smooth without using extra cement complete all as specified & directed by Engr-In-Charge.
24Rendering 15mm thick in cement mortar 1:6 on any face of Brick walls or concrete surfaces, finished even and smooth without using extra cement complete all as specified & directed by Engr-In Charge.
25M&L for 5 mm thick plaster on ceiling/ concrete surfaces in cement mortar (1:3) finished even and smooth without using extra cement complete all as specified and directed by Engr-In-Charge.
26M&L for preparation of Finishing walls with Acrylic Smooth exterior paint of required shade : New work (Two or more coat applied @ 1.67 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm) complete all as specified & directed by Engr-In-Charge.
27M&L for Preparation of new plastered surfaces and applying applying wall care putty on ceiling of 3 mm thickness over plastered surface to prepare the surface even and smooth and apply two coat of OBD on ceiling as specified & directed by Engr-In-Charge.
28M&L for preparation of new surfaces including 3 mm wall care putty on walls over plastered surfaces to prepare surface for receiving distempering two or more coats with 1st quality acrylic distemper (ready mixed) having VOC content less than 50 gms/litre, of approved manufacturer, of required shade and colour complete, as per manufacturer's specification including all preparation complete all as specified & directed by Engr-In-Charge.
29Providing and applying polyurethane liquid roof waterproofing with improved water ponding capability, thermal insulating elastomeric high build liquid membrane for concrete roofs for exterior wall and exposed surface with solid content not less than 80% and solar reflective index 106 as per (ASTM E1980-19)/tear strength ~20 N/mm (Free film, 14 days, +30 degree C) (ASTM D624) and tensile strength 2 N/mm2 (ASTM D4541).(a) Surface Preparation. Cleaning the screed surface to make it laitance, dust and sludge free, removing any extended portion by grinding using suitable equipment and providing basic repair including filling of any cracks or pot holes with crack seal. After proper surface preparation, Apply one coat of Primer for PU coating as per manufacturers specification.(b) Apply 1st coat of ShaliUrethane® BTD (white) @ 650 gm / m²(minimum) or equivalent by brush / roller while prime surface is tacky, Spread waterproofing reinforced Glass Fiber mash of 45 GSM with overlaps of 50 mm in both directions when the surface is still tacky. Allow 1st coat to dry. (c ) Apply 2nd & 3rd coat of ShaliUrethane® BTD (white) @ 650 gm / m² (minimum) or equivalent by brush/roller. Make : Fosroc/Sika/Choksey/Chemsol/Bostik/STPNote : (i) The Minimum dry film thickness (DFT) of roof treatment shall be 1.5mm if any shortfall in thickness of above treatment the same shall be achieved by additional coat. (ii) The procurement of material and execution of the work of water proofing treatment shall be carried out by authorised applicator approved by GE.(iii) The manufacturer/authorised applicactor shall give a warranty for the performance & durability for 10 years.
30S&F Providing and fixing factory made uPVC white colour fixed double shutter (one glazing and one gauzing) openable window area exc. 1.00 Sqm but not exceeding 2.00 sqm each made of extruded profiles with wall thickness of 2.3mm(+-0.2mm) with or without provisioning of opening for cooler. Window profile with hollow section with multi chamber. Frame (60mm x58mm). T profile (One vertical length in between two shutters) (60mm x 74mm). Glazing bead (35mm x 20mm) will be mitered cut and fusion welded at all corners, including drilling of holes for fixing hardware and drainage of water etc. making arrangement for fixing of hardware, EPDM gasket.1.2 +–0.2mm thick, galvanized steel Frame (28mm x 21.5mm), T profile (27mm x 17 mrn) to be inserted in required profile, frame will be fixed to the wall with 8mm x 100mm long fasteners- 5mm thick glazing with selected quality glass (Note:- The unit quoted by contractor excludes cost of glass/wiremesh and ncludes all other connected accessories net opening will be measured for payment purpose ) complete all as specified & directed by Engineer-in-Charge.
31S&F Providing and fixing factory made uPVC white colour fixed openable ventilator window area not exc. 1.00 Sqm each made of extruded profiles with wall thickness of 2.3mm(+-0.2mm). Window profile with hollow section with multi chamber. Frame (60mm x58mm). T profile (Onevertical length in between two shutters) (60mm x 74mm). Glazing bead (35mm x 20mm) will be mitered cut and fusion welded at all corners, including drilling of holes for fixing hardware and drainage of water etc. making arrangement for fixing of hardware, EPDM gasket.1.2 +–0.2mm thick, galvanized steel Frame (28mm x 21.5mm), T profile (27mm x 17 mrn) to be inserted in required profile, frame will be fixed to the wall with 8mm x 100mm long fasteners- 5mm thick glazing with selected quality glass (Note:- The unit quoted by contractor excludes cost of glass/wiremesh and ncludes all other connected accessories net opening will be measured for payment purpose ) complete all as specified & directed by Engineer-in-Charge.
32S&F for 4 mm thick sheet glass ordinary quality and glazing with spring clips in metal surrounds and oil putty in squares exceeding 0.50 sqm in each pane with solar control film 25 micron reflective size stick to glass panes asper instructions of manufacturers complete all as specified and as directed by Engineer-in-Charge.
33S&F for stainless steel wire cloth 0.36 nominal dia of wire and average width of aperture 1.40 mm and fixed with stainless steel wire staples complete all as specified and as directed by Engineer-in-Charge.
34S&F Factory made single extruded WPC (Wood Polymer Composite) solid door/ window/Ceosetory windows & other Frames/Chowkhat of size 45 x 85 mm comprising of virgin PVC polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/ wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) fabricated with miter joints after applying PVC solvent cement and screwed with full body threaded star headed SS screws having minimum frame density of 750 kg/ cum, screw withdrawal strength of 2200 N (Face) & 1100 N (Edge), minimum compressive strength of 58 N/mm2, modules of elasticity 900 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof,water/ moisture proof and fire retardant and fixed in position with MS hold fast/lugs/SS dash fasterners of required dia and length complete as per direction of Engr-in-charge. (M.S hold fast/lugs or SS dash fasterners shall be paid for separately.)
35S&F for Factory made single extruded WPC (Wood Polymer Composite) solid plain flush door shutter of 30 mm size comprising of virgin polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/wheat husk) and non toxic additives (maximum toxicity index of 12 for 100gms) having minimum density of 650 kg/cum and screw withdrawal strength of 1800 N (Face) & 900 N (Edge),minimum compressive strength 50 N/mm2, modulus of elasticity 850 N/mm2 and resistance to spread of flameof Class A category with property of being termite/borer proof, water/moisture proof and fire retardant and fixing with stainless steel butt hinges of required size with necessary full body threaded star headed counter sunk S.S screws and 02 Nos (Per leaf) SS 150 mm long Tower bolt and 02 Nos per leaf SS 150 mm long handle complete all as specified and directed.
36S&F Factory made single extruded WPC (Wood Polymer Composite) solid door/ window/Ceosetory windows & other Frames/Chowkhat of size 65 x 125 mm comprising of virgin PVC polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/ wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) fabricated with miter joints after applying PVC solvent cement and screwed with full body threaded star headed SS screws having minimum frame density of 750 kg/ cum, screw withdrawal strength of 2200 N (Face) & 1100 N (Edge), minimum compressive strength of 58 N/mm2, modules of elasticity 900 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof,water/ moisture proof and fire retardant and fixed in position with MS hold fast/lugs/SS dash fasterners of required dia and length complete as per direction of Engr-in-charge.(M.S hold fast/lugs or SS dash fasterners shall be paid for separately.)
37S&F for Factory made single extruded WPC (Wood Polymer Composite) solid plain flush door shutter of 35 mm thick size comprising of virgin polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/wheat husk) and nontoxic additives (maximum toxicity index of 12 for 100 gms) having minimum density of 650 kg/cum and screw withdrawal strength of 1800 N (Face) & 900 N (Edge), minimum compressive strength 50 N/mm2 , modulus of elasticity 850 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant and fixing with stainless steel butt hinges of required size with necessary full body threaded star headed counter sunk S.S screws, all as per direction of Engineer-In-Charge including supply and fixing following items :-(a) Stainless steel (304 Grade) finished butt Hinges 100 mm, 4 Nos per leaf and table 6 of BIS 12817-2020 BIS Marked.(b) Stainless steel (304 Grade) finished square tower bold 200 mm long-2 Nos per leaf as per table 01 dia of bolt 12 mm as per BIS 12833.(c) Stainless steel (304 Grade) Finished Handles 200 mm-2 Nos per leaf. (d) Stainless steel (304 Grade) finished sliding bold 300 mm-1 No per leaf, 16 mm dia as per BIS clause (iii) of BIS 15834-2020. (e) Stainless steel (304 Grade) Finished Floor door stopper 140 mm -1 Nos per leaf.
38S&F for Factory made single extruded WPC (Wood Polymer Composite) glazed and skeleton plain door shutter of 35 mm thick size comprising of virgin polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/wheat husk) and nontoxic additives (maximum toxicity index of 12 for 100 gms) having minimum density of 650 kg/cum and screw withdrawal strength of 1800 N (Face) & 900 N (Edge), minimum compressive strength 50 N/mm2 , modulus of elasticity 850 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant and fixing with stainless steel butt hinges of required size with necessary full body threaded star headed counter sunk S.S screws, all as per direction of Engineer-In-Charge. Including supply and fixing of stainless steel 304 Grade (natural finish) wire cloth complete all as direction of Engineer-in -Charge including supply and fixing of following items :-(a) Stainless steel (304 Grade) finished butt Hinges 100 mm, 4 Nos per leaf and table 6 of BIS 12817-2020 BIS Marked.(b) Stainless steel (304 Grade) finished square tower bold 200 mm long-2 Nos per leaf as per table 01 dia of bolt 12 mm as per BIS 12833.(c) Stainless steel (304 Grade) Finished Handles 200 mm-2 Nos per leaf. (d) Stainless steel (304 Grade) finished sliding bold 300 mm-1 No per leaf, 16 mm dia as per BIS clause (iii) of BIS 15834-2020. (e) Stainless steel (304 Grade) Finished Floor door stopper-1 140mm Nos per leaf.(f) Stainless steel (304 Grade) wire cloth fixing as per manufacturer's instructions
39S&F Glazed ceramic coloured tiles with highlighter in vertical surface 450x300x7mm thick set and jointed in neat cement slurry and pointed in white or colour cement to match including 15 mm thick rendering in CM 1:4 on other than fair face of brick work. (Highlighter shall be provided as directed by Engr-in-Charge)
40S&F three layered rotational moulded polyethylene water storage tanks (cylindrical vertical with closed top) 1000 Ltr capacity hoisted and fixed in position all as specified including PVC float valves, high pressure, with polythene float and fly nut complete screwed for 20mm bore iron pipe & dismantling existing water tank complete all as specified and directed by Engr-in-charge.
41S&F 25mm (outer dia) PP-R Gate valves (brass insert) as per requirement of the site with iron wheel head, fixed both ends of pipe complete all as specified and directed.
42Supplying and laying of CPVC pipes ISI SDR 11 pipe 20mm(outer dia)(15mm inner dia) with all fittings solvent and fixed to wall and Ceiling or laid in floor complete all as specified and directed by Engr-in-Charge.
43Supplying and laying of CPVC pipes ISI SDR 11 pipe 25mm (outer dia)(20mm inner dia) with all fittings solvent and fixed to wall and Ceiling or laid in floor complete all as specified and directed by Engr-in-Charge.
44S &F Vitreous China wash hand basin size 550x400 mm size with pedestal, pair of brackets, waste pipe, waste coupling complete all as specified.
45S&F Vitreous china premium/ 1st quality wash down water closet wall hung EWC white/ ivory/off white (closed pattern incl all necessary accessories like duraplast seat cover, rag bolts/ gel gasket etc and ABS body health faucet CP jet spray with 1.50 mtr long fexible tube including fixing arrangement complete in all respect all as specified.
46S&F one piece/Single body PVC blow moulded conceled cistern, pneumatic type; capacity 9-10 litres, including chrome finish dual flush control plate, flushing pipe and fixing brackets complete assembled and fixed at site.
47S&F PVC connection, 15mm size with PTMT nuts of length 450mm complete all as specified and directed.
48S&F 6mm thick looking mirror fixed to wall with stainless steel plugs/connecter/spacers/screws etc. chrome finish with wooden beading french polished, etc.complete fixed in position all as specified and directed.
49S&F 15mm bore angle cock, cast copper alloy,chromium plated, screwed down for high pressure with crutch or butter fly handle, screwed both ends of pipe complete all as specified and directed.
50S&F Grating doom, 100 mm dia of PTMT (minimum weight 25gms) complete all as specified and directed
51S&F Fancy type Chromium plated shower roses 125mm size with arm, with or without swivel joints, 15mm bore, including fixing to steel pipe or union.
52S&F 15 mm dia Swan neck pillar tap, fancy type, cast copper alloy chromium plated with capston head, screwed down high pressure with or without lettered hot or cold with long screwed shank and fly nuts, screwed for pipe complete all as specified and directed by Engineer-in-Charge.
53M&L of uPVC (SWR) floor trap 75 mm bore plain with grating including jointing with solvent cement fixed to wall/laid in trenches etc complete all as specified and directed by Engineer in Chrge.
54Supply & fixing 75mm bore uPVC pipes grade 'B' single socketed in any length with rubber ring joints, fixed along walls/tranches with and including suitable size clamps/brackets (interval of 1m and pipe keeping 100mm away from wall ) of suitable size fixed with fasteners/nut bolts, joints fixed with pipe joint lubricant complete including bends, socket , Y junction, Tee , cowl etc all as specified and as directed by Engineer-in- charge complete including low carbon hot roll gauge corrected oil pickled & drawn pipe supporting clamping system 32x3mm with rib and notch are hot dip galvanised and Zn, Al flake coating with necessary clamps to fix and hold pipe complete all as specified and directed. (Note: Detail of Pipe supporting system is all as per Drg NO -BTD-916) Note:-UPVC PIPE AND FITTING/ FIXTURE- (i) The testing for leakage of pipe shall be done before connecting the pipes (ii) All pipes shall be minimum 4\\" away from walls fixed with GI bracket (iii) The gully trap shall be minim um 90 cm away from wall. (iv) Separate pipes for each floor should be provided (v) Sewage and drain system shall be separate
55S & F 75 mm bore of pipe uPVC pipes grade 'B' bends heavy grade of any radius / shoe fixed to uPVC pipes as directed
56Supply & fixing 110mm bore uPVC pipes grade 'B' single socketed in any length with rubber ring joints, fixed along walls/tranches with and including suitable size clamps/brackets (interval of 1m and pipe keeping 100mm away from wall ) of suitable size fixed with fasteners/nut bolts, joints fixed with pipe joint lubricant including bends, socket , Y junction, Tee , cowl etc complete all as specified and as directed by Engineer-in- charge complete including low carbon hot roll gauge corrected oil pickled & drawn pipe supporting clamping system 32x3mm with rib and notch are hot dip galvanised and Zn, Al flake coating with necessary clamps to fix and hold pipe complete all as specified and directed. (Note: Detail of Pipe supporting system is all as per Drg NO -BTD-916). Note:-UPVC PIPE AND FITTING / FIXTURE- (i)The testing for leakage of pipe shall be done before connecting the pipes (ii) All pipes shall be minimum 4\\" away from walls fixed with GI bracket (iii) The gully trap shall be minim um 90 cm away from wall.(iv) Separate pipes for each floor should be provided (v) Sewage and drain system shall be separate.
57S & F 110 mm bore uPVC pipes grade 'B' bends heavy grade of any radius / shoe fixed to uPVC pipes as directed
58M & L for Salt-glazed stoneware gully traps of size 150 x 150 mm, square or round mouthed, type 'P' complet all as specified.
59M&L mild steel framed work of Fe-290 (Gde E-165) as in grills/guard bars shouldered with steel windows/ventilators frames. Cooler stand, ladder etc including redoxide primer coat complete all as specified
60Material and labour DWCPE (SN8) pipe complete laid in trenches and jointed including testing alongwith necessary jointing material tees/union/socket etc complete laid on Single filling as specified after they are laid and tested complete all as specified in IS 16098:2013 and as directed by Engg-in-Charge(a) 150 mm dia nominal dia
61Material and labour DWCPE (SN8) pipe complete laid in trenches and jointed including testing alongwith necessary jointing material tees/union/socket etc complete laid on Single filling as specified after they are laid and tested complete all as specified in IS 16098:2013 and as directed by Engg-in-Charge(b) 200 mm dia nominal dia
62M&L for single filling in trenches and paving, laid in layers n exc 15 cm thick, spread levelled, and blinded with earth and ramming including weathering complete all as specified and directed
63M&L for Cement concrete in foundations, filling and mass concrete 1:3:6 type C-2 (40 mm graded aggregate) complete all as specified and directed by engineer in charge.
64M & L for cement concrete (1:2:4) type B-1 (using 20mm graded stone aggregate) for manhole manhole channel rounded or chamfered on edge included neccessary formwork complete all as specified and directed
65Providing precast cement cocrete in landings, cover slabs (for manholes etc.) chullah hoods, chajjas, water troughs, mangers shelves and similar articles with plain faces type B1 1:2:4 (20 mm graded aggregate) & set in CM (1:6) complete
66Extra for forming fair finish to drain or channel 30 cm internal girth in cement concrete using extra cement including forms moulds/mitred stopped ends etc.
67Mild steel bars 8 mm dia , cut to length, bent to shape reqired including cranking, bending spirally for hooping for columns hooking ends and binding with mild steel wire (annealed) not less than 0.9 mm dia or securing with clips quality conforming to TMT bars
68M&L Rendering 15 mm thick on fair faces of brick work or concrete surfaces with Cement plaster (1:4) etc complete all as specified and directed.
69Supply only integral water proofing compound.
70Returning, filling in, including spreading, levelling, watering and well ramming in layer not exc 25 cm.
71Removing excavated material not exceeding 50 m and depositing where directed.
72Excavating in post holes (or similar holes) each n exc 0.5 cu. m, getting out, returning, filling in and ramming earth or broken rubble mixed with earth around, in layers not exceeding 25 cm,
73Surface excavation n.exc 30 cm deep averaging 15cm and gettingout in soft / loose soil complete all as specified and directed
74Removal of excavated soil to a distance n exc. 50 Mtr and deposited where directed at a level n exc. 1.5 m above the starting point.
75Providing and laying 80mm thick factory made chamfered edge cement concrete paver block of M-30 grade with approved colour, design & pattern as in footpath, parks, lawns, drive ways or light traffic parking etc., of required strength, thickness & size/ shape, made by table vibratory method using PU mould, laid in required colour & pattern over and including 50mm thick compacted bed of coarse sand, compacting and proper embedding/ laying of inter locking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with fine sand and cutting of paver block as per required size and pattern, finishing and sweeping extra sand; complete all as specified and directed by Engr-In-Charge
76M&L for PCC 1:3:6 type C2 40mm stone aggregate filling mass concrete in columns, pillars,boundary pillars and posts complete all as specified and directed by Engr-In-Charge.
77M&L for PCC 1:2:4 type B0 ( using 12.5 mm graded stone agg) as in road kerb and the like including weathering, slightly rounded or chamfered angles and throating, as directed
78S& F Rolled mild steel in Joist, channel, angle, or tee sections, fixed independently, without connecting plates including connections, bending and welding as necessary complete all as specified & directed by Engr-In-Charge.
79Pre- painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws as specified & directed by Engr-In-Charge
80M&L for preparation of newly Surfaces of any description, over 10cm in width or girth,not otherwise described and applying a coat of synthetic enamel paint(ordinary tint) all as specified & directed by Engr-In-Charge
81Supply and laying Reinforced concrete pipes with collars 450 mm internal diameter,class NP3, laid and jointed with stiff mixture of cement mortar (1:2) complete all as specified & directed by Engr-In-Charge
82Point wiring complete with ISI marked 2.5 sqmm single core PVC insulated unsheathed cable 1100V grade FRLSH with multistranded copper conductor drawn through & including PVC rigid concealed conduit suitable size with all accessories bend reducers,MS hooks,MS junction boxes,terminal boxes & including modular steel terminal boxes factory made and cover modular plate with frame suitable for (modular switches, sockets, fan regulator) & including 2.5 sqmm copper conductor as earth continuity to connect common earth dolly complete for the following all as specified and as directed:- (a) One light point/Fan point/Exhaust point controlled by one way switch
83(b) One three pin socket out let 5 amps on the same board with other switches
84(c) One 3 pin, 5A switch socket outlet point on independent board
85(d) One bell point controlled by one bell push
86All as per item no. 84 here-in-before but with 4 sqmm cable for 1No 16 amps socket outlet point on independent board including 4 sqmm PVC insulated unsheathed cable multistranded with copper conductor green in colour as earth continuity conductor.
87Supply and fixing of LED tube light fiting 20W, 230 V, wall mounted LED batten with polycarbonate housing & integrated electronic driver and including connections up with copper conductor wire with suitable size as per specification and directed by Engineer-in-chrg.
88Supply and fixing of LED tube light fiting 10W, 230 V, and wall mounted LED batten with polycarbonate housing & integrated electronic driver and including connections up with copper conductor wire with suitable size all as per specification and directed by Engineer-in-chrg.
89M&L ceiling rose 3 terminal / PVC / polycarbonate isolated body
90S&F Moduler switch single pole 1 way 6 amps,1 Module 230 volt AC supply complete all as specified and directed by Engr-in-Charge.
91S&F Moduler socket two in one 2/3 Pin 6 Amps 2 Module 230 volt AC supply complete all as specified and directed by Engr-in-Charge.
92S&F Moduler type switch single pole 1 way 16 amps,1 Module 230 volt AC supply complete all as specified and directed.
93S&F Moduler socket 2/3 Pin 16 Amps 2 Module 230 volt AC supply complete all as specified and directed by Engr-in-Charge.
94Supply and fixing Modular switch bell push 6 amps one module all as specified and directed.
95S&F Bell ding dong AC 230V single pole complete all as specified and directed .
96M&L submain wiring with two single core PVC FRLSH insulated copper conductor 4 sqmm and same 4 sqmm for continuous earth wire drawn in concealed PVC conduit & including PVC rigid concealed conduit complete all as specified and directed by Engr-in-Charge. Note: Cost of earth wire including in sub main wiring.
97Supply and fixing amp rating 240V, 10KA 'B' curve miniature circuit breaker (MCB) of SPN 32 AMP and current carrying capacity in the MCB DB complete with connection all as specified and directed.
98Supply and fixing 240V, 10 KA 'B' curve miniature circuit breaker (MCB) of single poles and current carrying capacity 6 to 32 AMP, in the MCB DB Complete with connection all as specified and directed.
99S&F sheet metal enclosure for DB's SPN 230 volts 8 way double door complete all as specified and directed.
100Supply and fixing energy efficient LED Security light fitting of 35W pressure die cast aluminium housing/body,along with fitting bracket, 1.0 mtr long made out of galvanised iron pipe medium grade complete with nuts, bolts, washer, clamps etc inclusive of one primer coat, one under coat and one finishing coat of silver paint complete all as directed, heat resistant clear toughened glass, better optics for uniform distribution street/Roadway luminaire, with driver, including electric connection, complete fitting with all accessories and following specifications:(a) Lumen system efficacy of luminaire should be minimum 100 Lumen per watt. (b) Input Voltage range : 140 to 270 volts (c) Temp operating range : Minus 10°C to Plus 50°C (d) Power factor : Minimum 0.95 (e) THD : Max10%. (f) IP rating : IP66. (g) IK rating : Minimum IK07 (h) Built in potted LED Driver of the same make as of the luminaire.(j) LED driver should be complete with all protections viz open/short circuit protection, over voltage protection, all as per standard design of manufacturer. (k) Surge protection 10 kV (inbuilt + extended) (l) CCT : 5700 K. (m) CRI : Morethan 80 (n) Lens - High Efficiency wide angle lens. (o) BIS Approved fixtures and driver (p) Rated life time : 50000 burning hrs (Average 10 to 12 hrs daily)
101Supply & fixing ceiling fans BLDC type regulator operated complete with blades, down rods and accessories, 230 V, 1200 mm sweep,service value not less than 6.0 with brushless direct current motor (BLDC) complete all as directed
102Supply and fixing fan step regulator, 120W - 1 module complete all as specified and directed
103Supply and fixing in of ventilating fan 200 mm sweep plastic body type including self cosing louver and making all electric connections complete all as directed.
104M&L for Earthing complete with galvanised steel earth plate electrode 600mm x 600mm x 6mm thick burried directly in ground vertically to a depth not less than 2.25 metre below ground level with top edge of earth plate at a depth of not less than 1.5 metre below ground level, earth plate surrounded by 15cm thick and packed layer of charcoal dust and common salt, connected to earth lead of GI wire 4 mm dia (8 SWG) by means of bolts, nuts and washers of the earth wire galvanised iron or steel and thimbles and other end of the earth wire connected to earthing test point and protected by galvanised iron pipe light grade 15mm dia and water pipe 20mm dia GI light grade with funnel & wiremesh, PCC chamber in cement concrete (1:2:4) type B1 including 40mm thick pre-cast RCC (1:2:4) type B0 cover and 40x40x6mm angle iron frame on top of pit cover and excavation & earth work complete all as shown in electrical plate No. 3 of MES Schedule Part-I of SSR-2009. complete all as specified and directed by Engr-in-charge.Notes :- (i) GI wire upto earth test point/equipment is included in this item. (ii) Outer edge of earth pit chamber shall be 1 metre away from the outer edge of PCC chamber. (iii) Minimum weight of reinforcement shall be 1 Kg for each earth pit cover.
105Supply and fix electric water heater(geyser), storage type steel body with stainless steel inner tank with glass lining and heating element capacity 25 litre, BEE 5 Star rated complete with all accessories such as safety valve, thermostate,NRV, connection piece etc. complete with all accessories.
106S & F DBOXx SRCD (Socket Residual Current Device) is ready plug & play all -in-one device that provides protection to humans from electric shock due to direct or indirect contact as well as provides protection from overload and short circuit faults Single pole complete with one SPN MCB 20 Amps, 240 V, AC supply, and plug top all type as specified and directed by Engr-in-Charge.
107Supply and fix desert cooler electric driven (single phase), having nominal air flow capacity of 4000 CuM per hour (or nearest size).Steel Body complete all as specified and directed by Engr-in-charge.
108Supply and lay pipe galvanized, “Medium class”, 15 mm (1/2”) dia bore including all fittings and fixed complete to wall ,RM ceiling or laid in floor complete all as specified and directed
109Supply and fix Valve, stop, screwed,15 mm (1/2”) dia pipe complete all as specified and directed.
110Cutting existing steel tubing for alterations or additions (Each cut measured) for 40 mm Gi pipe complete all as specified and directed.
111Supply and laying steel water Tubeing, 40 mm dia ISI Marked, 'Medium grade' galvanised, including tube fittings Viz Tees Socket bends elbows, union nipple etc screwed and socketed joint laid in trenches/under road with all fitting.
112S&F GI Pipe 25mm bore Medium grade and including GI Fitting in Trenches/on Wall or Laying in floors complete all as specified and directed .
113S&F Gun-metal, globe or gate valves with iron wheel head screwed both ends for iron pipe & fixed 25 mm bore of pipe complete all as specified and directed.
114Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 10 sq mm 2 core
115Excavating in trenches, not exceeding 1.5 m wide and not exceeding 1.5 m in depth for laying of cables, pipes etc. and getting out including trimming the sides and forming bottom surfaces to required levels in soft/loose soil complete all as specified and directed.
116Supply and laying double wall corrugated pipe (DWC SN 4), non-metallic, Resistance to Compression : Type 450, Resistance to Impact: Normal, Resistance to Bending : Pliable, Resistance to External Influence: Ingress Protection : IP 67, Resistance against Corrosion : Without Protection, Resistance to Flame Propagation : Non Flame Propagating, Nominal outside diameter 50 mm, minimum inside dia 37 mm conforming to IS 16205 (Part 24) : 2017 complete all as specified and as directed.
117Supply and laying steel water Tubeing, 50 mm dia ISI Marked, '“light grade' galvanised, including tube fittings Viz Tees Socket bends elbows, union nipple etc screwed and socketed joint laid in trenches/under road with all fitting complete all as specified and directed. Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 56695387
AUTHORITY Statutory Bodies & Commissions/Committees
TENDER VALUE 33 Lakhs
LAST DATE 15-08-2026
Authority
Authority Name Military Engineer Services
Work Description Tender For Provision Of 02 X Single Jcos Living Accommodation (Otm) And Certain Other Sanctioned Work At Faridkot Mil Stn
Basic Detail
Tender No GE/FRD-31/2026-27
Bidding Type Tender
Location
City Faridkot
State Punjab
Key Dates
Publish Date 27 Jul 2026
Submission Date 15 Aug 2026
Open Date 17 Aug 2026
Finance
Tender Value 33 Lakhs
Tender Fee 500
EMD 66000
Exemption Available
Document List
BOQ_874946.xls
d1193cb6-c02b-4673-a754-4676a018fa00.html
TenderDocuments31.pdf
Tendernotice_1.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Jul 27, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Aug 15, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 7 days
Aug 17, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 9 days

Tender Documents

Download All (ZIP) ↓
xls

BOQ_874946.xls

html

d1193cb6-c02b-4673-a754-4676a018fa00.html

pdf

TenderDocuments31.pdf

pdf

Tendernotice_1.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail
Loading tenders