Tender For Operation And Maintenance Of 4.54 Mld Capacity Bank Note Press Water Supply Scheme In Block And District Shajapur & Dewas Comprising Of Raw Water & Clear Water Pumping Stations, Water Treatment Plant, Electric Sub Station, Pumping Mains An
Tender Overview
Project Description
Tender for Operation And Maintenance Of 4.54 Mld Capacity Bank Note Press Water Supply Scheme In Block And District Shajapur & Dewas Comprising Of Raw Water & Clear Water Pumping Stations, Water Treatment Plant, Electric Sub Station, Pumping Mains And Allied Works Including All Required Materials, Consumables, Chemicals, All Labour Etc Complete (Excluding Raw Water & Energy Charges) Required For Successful Operation Of The Scheme For Three Years.
BOQ
| Sl. No. | Item Description |
| 1 | Operation and Maintenance of 4.54 MLD capacity Bank Note Press Water Supply Scheme in Block and District Shajapur & Dewas comprising of Raw Water & Clear Water Pumping Stations, Water Treatment Plant, Electric Sub Station, Pumping Mains and allied works including all required materials, consumables, chemicals, all labour etc complete (excluding raw water & energy charges) required for successful operation of the scheme for three years. |
| 2 | Operation & routine maintenance of raw water pumping station including required T & P, staff, consumable items like grease, etc with Charges for commercial vehicle for operation and maintenance of whole scheme . |
| 3 | Operation & routine maintenance of Water treatment plant including required T & P staff, consumable item like chemical/Glassware etc for water purification and water testing complete. |
| 4 | Operation & routine maintenance of clear water pumping station including required T & P, staff, consumable items like greas etc. for operation and maintenance of whole scheme . |
| 5 | Operation and routine maintenance of raw/clear water pumping main including all labour ,required T&P and etc complete. |
| 6 | Repairing and rewinding of raw water motor i/c dismantling, repairing and reinstallation with cost of all material and all labour complete |
| 7 | Repairing and rewinding of clear water motor i/c dismantling, repairing and reinstallation with cost of all material and all labour complete |
| 8 | Opening overhauling of oil chamber of 120 HP raw water centrifugal motor pump of intake at lakhunder and filling fresh oil of Standard make as per direction of Engineer in Charge including cost of oil , all labour etc complete. |
| 9 | Opening overhauling of gear boxes of WTP and filling fresh oil of standard make as per direction of Engineer in Charge including cost of oil , all labour etc complete. |
| 10 | Job work for repairing of panel board,Air Compressor,blower, agitator/ motor for alum tank,gates, chlorinator /chlorine supply system ,bridge & other E/M miscelleneous item etc of WTP in a year |
| 11 | Job work for repairing of elecrical accessories, fixtures,bulbs, tubelights , helogen lamps,CFL ,LED lights as per requirements at Intake , WTP, Administrative bulildings etc complete including cost of all material, labour etc complete in a year. |
| 12 | Replacement of gland of 120 HP Raw water centrifugal motor pumps at lakhunder Intake of both ends DE & NDE including all material, labour, testing etc. complete . 2 pumps x 12 months = 24 Job per year |
| 13 | Replacement of gland of 12.5 HP Clear water centrifugal motor pumps at WTP of both ends DE & NDE including all material, labour, testing and commissioning etc complete. 2 pumps x 12 months = 24 Jobs per year |
| 14 | Replacement of gland of 5 HP Wash water centrifugal motor pumps at WTP of both ends DE & NDE including all material, labour, testing etc. complete. 2 pumps x 12 months = 24 Jobs per year |
| 15 | Providing and fitting of bearing of standard make in raw water 120 H.P. electric moter i/c dismantling, opening and fitting of new bearing and reinstallation work include cost of all material and labour complete.bearing No6314/C3 |
| 16 | Providing and fitting of bearing of standard make in raw water 120 H.P. electric moter i/c dismantling, opening and fitting of new bearing and reinstallation work include cost of all material and labour complete.bearing No316ECJ/C3 |
| 17 | Re filling of fire Extinquisher. ABC type,capacity 5kg |
| 18 | Re filling of fire Extinquisher. BC type,capacity 5kg |
| 19 | Re filling of fire Extinquisher. ABC type,capacity 1 kg |
| 20 | Providing & fitting of ABC type 5 kg capacity complete filled fire Extinquisher |
| 21 | Providing and fitting of 150 mm dia.cast iron flanged footvalve for clear water pumps. |
| 22 | Supplying of ISI Marked and approved make of Moulded Case Circuit Breaker (MCCB) suitable for 3 phase,3 pole, 50 Hz, 415 Volts, AC supply with respective interrupting capacity (KA) at 415 Volts cited against their range standard conforming to IS – 8828, MCCB 25 KA, 3P , 415 V, MCCB 100Amp. & Adjustable: 80% -100% thermal |
| 23 | Supplying of ISI Marked and approved make of Moulded Case Circuit Breaker (MCCB) suitable for 3 phase,3 pole, 50 Hz, 415 Volts, AC supply with respective interrupting capacity (KA) at 415 Volts cited against their range standard conforming to IS – 8828, MCCB 25 KA,3P , 415 V, MCCB 160Amp. & Adjustable: 80% -100% thermal |
| 24 | Supplying of ISI Marked and approved make of Moulded Case Circuit Breaker (MCCB) suitable for 3 phase,3 pole, 50 Hz, 415 Volts, AC supply with respective interrupting capacity (KA) at 415 Volts cited against their range standard conforming to IS – 8828, MCCB 25 KA,3P , 415 V, MCCB 200Amp. & Adjustable: 80% -100% thermal |
| 25 | Supplying of ISI Marked and approved make of Moulded Case Circuit Breaker (MCCB) suitable for 3 phase,3 pole, 50 Hz, 415 Volts, AC supply with respective interrupting capacity (KA) at 415 Volts cited against their range standard conforming to IS – 8828, MCCB 400 Amp ,36 KA, 3P , 415 V, MCCB 400Amp. & Adjustable: 80% -100% thermal |
| 26 | Supplying of ISI Marked and accepted standard of Miniature Circuit Breaker (MCB) of 'C' series suitable for 240/415 Volts, 50 Cycle , 10 kA Value AC supply confirming to IS : 8828 : 1996, IEC : 60898 :2002 but without enclosures :- SINGLE POLE (SP), 0.5 Amp to 5 Amp,10KA Rating |
| 27 | Supplying of ISI Marked and accepted standard of Miniature Circuit Breaker (MCB) of 'C' series suitable for 240/415 Volts, 50 Cycle , 10 kA Value AC supply confirming to IS : 8828 : 1996, IEC : 60898 :2002 but without enclosures :- SINGLE POLE (SP), For 40 Amps,10 KA Rating. |
| 28 | Supplying and fixing of LT Panel accessories of approved make in existing LT Panel including connections etc.as required as per spececification - Digital Ampere Meter with CTs with selector switch per set 1950 |
| 29 | Supplying and fixing of LT Panel accessories of approved make in existing LT Panel including connections etc.as required as per spececification -Digital Volt Meter with selector switch & HRC fuse per set 2100 |
| 30 | Supplying and fixing of LT Panel accessories of approved make in existing LT Panel including connections etc.as required as per spececification - Multifunctional meter |
| 31 | Supplying and fixing of LT Panel accessories of approved make in existing LT Panel including connections etc.as required as per spececification -Copper Bus bar strips with PVC sleeves . |
| 32 | Supplying and fixing of LT Panel accessories of approved make in existing LT Panel including connections etc.as required as per spececification -Aluminium bus bar strips with PVC sleeves |
| 33 | Supplying and fixing of LT Panel accessories of approved make in existing LT Panel including connections etc.as required as per pececification -LED lamp indicator |
| 34 | Providing and fitting of connecting terminal plate of 120 HP electric moter i/c removing of burnt plate and fitting of new plate with all labour and material complete with testing . |
| 35 | Repairing and rewinding of ATS transformer of control pannel of 120 HP electric moter pump set work include dismantling and reinstallation after rewinding complete with all material and labour. |
| 36 | Providing and fixing on off switch. |
| 37 | Providing and fixing single phase preventor. |
| 38 | Providing and fixing new timer. |
| 39 | Supplying and erection of single piece non-linear resistor type lightning arrestor (set of 3 nos) for 3 wire, 33KV overhead lines/sub-station with rated voltage of 30KV (rms) with a nominal discharge current rating of 5 KA and complete with galvanized clamping arrangement, G.I. bolts, nuts, washer etc. as required |
| 40 | Supply and filling of new transformer oil of desired break down value for topping as reqd |
| 41 | Filtration of transformer oil for 33/0.4 KV, 11/0.4 KV 3 phase 50 cycle oil immersed, naturally cooled, distribution transformer upto desired break down value |
| 42 | Providing & Fixing 33 KV D.O Post Insulator |
| 43 | Providing & Fixing 33 KV A.B. Post Insulator |
| 44 | Providing and fitting 33 KV D.O. Fuse |
| 45 | Supply of hand gloves 33 kv tested |
| 46 | Earth work in excavation for foundation, trenches for pipes/ cables, drains or in well excavation etc. by mechanical means/ manual means (exceeding 30cm in depth.) including ramming of bottom,dressing of sides disposal of excavated earth including of all lift and lead upto 50m. disposed earth to be levelled and neatly dressed.-All kind of soil |
| 47 | Earth work in excavation for foundation, trenches for pipes/ cables, drains or in well excavation etc. by mechanical means/ manual means (exceeding 30cm in depth.) including ramming of bottom, dressing of sides disposal of excavated earth including of all lift and lead upto 50m. disposed earth to be levelled and neatly dressed.-In muddy area. |
| 48 | Earth work in excavation for foundation, trenches for pipes/ cables, drains or in well excavation etc. by mechanical means/ manual means (exceeding 30cm in depth.) including ramming of bottom, dressing of sides disposal of excavated earth including of all lift and lead upto 50m. disposed earth to be levelled and neatly dressed. soft rock with or without blasting. |
| 49 | Pumping out water caused by springs, tides or river seepage, broken water mains or drains or the like |
| 50 | Filling available excavated earth in trenches, lead up to 50m and lift up to 1.5m in all kind of soil excluding watering and ramming. |
| 51 | Providing & laying mechanically mixed cement concrete 20mm nominal size graded crushed stone excluding cost of centering & shuttering.1:11/2:3 (M-20 ) |
| 52 | Providing & laying mechanically mixed R.C.C. excluding centering & shuttering and reinforcement in foundation/plinth (20mm graded metal)(M-20 ) |
| 53 | Providing and placing in position cold twisted steel and hot rolled deformed steel reinforcement for R.C.C. work i/c cutting, bending, binding etc. complete i/c cost of binding wire and wastage. |
| 54 | Providing & fixing form work i/c centering and shuttering including strutting, propping etc. and removal of form work for:Foundation , footing, bases of columns ,etc for mass concrete |
| 55 | Providing & fixing form work i/c centering and shuttering including strutting, propping etc. and removal of form work for:Columns, pillars, piers, Abutments, posts and Struts |
| 56 | Fabrication of M.S. pipes & specials as per IS specifications with inside & outside epoxy coating as per relevant IS code, duly tested for usage in Drinking water inclusive of all materials, inspection charges, transit insurance, loading/unloading, FOR site, & stacking etc. complete as for direction of Engineer-in-Charge |
| 57 | Providing and Laying Ductile iron Mechanical joint collar with follower glands conforming to IS-9523/2000 having dimension as per table 24 of IS-9523/2000 in the following nominal diameter/sizes with external bitumen and internal cement mortar lining. 300 mm dia |
| 58 | Providing and Laying Ductile Iron any type of specials having dimension as per relevant table of IS- 9523/2000 in the following nominal diameter/sizes with external bitumen coating and internal cement mortar lining. 300 mm dia |
| 59 | Providing Rubber ISI marked Gasket (push on) joint as per IS-5382/85 to following DI pipes class K-7 and K-9 including testing of joints and cost of jointing materials (Rubber Gasket and soap solution etc.) 300 mm dia |
| 60 | Labour charges for repairing of 80 to 300 mm dia Sluice/NR valves including cost of required materials and all labour complete. |
| 61 | Labour Charges for repairing of any type and any size of air valves including cost of required materials and all labour complete. |
| 62 | Supply and providing lead of best quality for repairing of pipe lines. |
| 63 | Supply and providing rubber gaskets suitable for 300 mm dia DI pipes of best quality for repairing of pipe lines. |
| 64 | Providing & fixing of following Cast iron double flanged sluice valves as per I.S.:14846-2000 fitted with cast iron cap including jointing & testing with cost of jointing material such as bolts, nuts, rubber insertions etc. all complete. 80 mm dia PN 1.0 |
| 65 | Providing & fixing of following Cast iron double flanged sluice valves as per I.S.:14846-2000 fitted with cast iron cap including jointing & testing with cost of jointing material such as bolts, nuts, rubber insertions etc. all complete. 80 mm dia PN 1.6 |
| 66 | Providing & fixing of following Cast iron double flanged sluice valves as per I.S.:14846-2000 fitted with cast iron cap including jointing & testing with cost of jointing material such as bolts, nuts, rubber insertions etc. all complete. 100 mm dia PN 1.0 |
| 67 | Providing & fixing of following Cast iron double flanged sluice valves as per I.S.:14846-2000 fitted with cast iron cap including jointing & testing with cost of jointing material such as bolts, nuts, rubber insertions etc. all complete. 200 mm dia PN 1.6 |
| 68 | Providing & fixing following cast iron double acting air valves, flanged without inbuilt isolating valve as per IS: 14845-2000 including jointing & testing with cost of jointing material and rubberinsertion all complete as per IS :13095-1991. 80 mm dia PN 1.0 |
| 69 | Providing & fixing following cast iron double acting air valves, flanged without inbuilt isolating valve as per IS: 14845-2000 including jointing & testing with cost of jointing material and rubberinsertion all complete as per IS :13095-1991. 100 mm dia PN 1.0 |
| 70 | Report of examination of pressel vessels in form No. 9 ,prescribed under rule 67 of m p factory rule 1962 by comptent authority. Air Receiver |
| 71 | Report of examination of pressel vessels in form No. 9 ,prescribed under rule 67 of m p factory rule 1962 by comptent authority. Chlorine pipe line. |
| 72 | Report of examination of lifting machine,chaine,rope,lifting ackles under sub section (a) iii of section 29 of m p factory rule 1962 by comptent authority. |
| 73 | Charges for hydraulic testing of 100 kg capacity empty chlorine cylinder and providing test report in standard form as per department of health and safety i/c loading unloading transportation complete. |
| 74 | providing and fitting of Gravityfeed chlorinator as per specification i/c transportation to site ,installation testing, commisning and making connection with existing pipe system complete with all labour ,material etc complete. |
| 75 | Electromagnetic Bulk Flow MetersSupply of Electromagnetic full bore meter complete as per specification including transportation to site, storage, safety, installation, testing, ommissioning, making connections with existing pipe line, including excavation at site, cuts in the existing pipe system, dewatering and reinstating the same after completion of installation as per specification and drawings including all taxes. Accuracy of meter + 0.3% of measured value, Flangeconnection as per AWWA & IS, Liner:Hard Rubber, Fully welded sensor housing complying to IP 68 standard, Electrodes SS 316, Sensor housing SS 304, Cable gland 1/2\\" NPT, Sensor housing fully welded SS 304 housing with protective Polyurethane paint, Flow Transmitter/ Converter: Microprocessor based, modular design display 2 line back lit LCD for indication of actual flow rate, forward, reverse, sum totalizer, Perfection category: IP 65 Output: One current output (4-20 mA) one scalable pulse output 250 mm dia.for clear water |
| 76 | Electromagnetic Bulk Flow MetersSupply of Electromagnetic full bore meter complete as per specification including transportation to site, storage, safety, installation, testing, ommissioning, making connections with existing pipe line, including excavation at site, cuts in the existing pipe system, dewatering and reinstating the same after completion of installation as per specification and drawings including all taxes. Accuracy of meter + 0.3% of measured value, Flangeconnection as per AWWA & IS, Liner:Hard Rubber, Fully welded sensor housing complying to IP 68 standard, Electrodes SS 316, Sensor housing SS 304, Cable gland 1/2\\" NPT, Sensor housing fully welded SS 304 housing with protective Polyurethane paint, Flow Transmitter/ Converter: Microprocessor based, modular design display 2 line back lit LCD for indication of actual flow rate, forward, reverse, sum totalizer, Perfection category: IP 65 Output: One current output (4-20 mA) one scalable pulse output |
| 77 | Supplying & installation of approved make required capacity single phase, 50 Hz, 230V, open well submersible pump, with control panel starter with dry run protection, connections, etc. as required as per specifications but excluding pipe and connection cable. 0.5 HP head mt. 6--20 Discharge LPM 2--61 W/o starter |
| 78 | Lalour only for installation of induction or submersible motor pump set with fitting of suction and delavery pipes fitting of foot valve etc. i/c transportation of above material from intake to site of work with loading and unloading complete. |
| 79 | Labour charges for electrician cum pump operator for operation of the motor pump at up stream side of dam. 365 daysx 3 shift =1095 mandays per year |
| 80 | Labour charges for watch man for safety of pipe line ,motor pump eletric cable,control pannel etc. 365 daysx 3 shift = 1095 mandays per year |
| 81 | Charges for jointing of 25/35/50 sq.mm armod cable including detaction of fault, cutting jointing and testing work with all labour and material charges complete. |
| 82 | Leakage repairing work of 160 mm dia. HDPE pipe line with all required labour, material and machinery including testing of work. |
| 83 | Labour only for laying and jointing of electric armod power cable of 25/35 sq. mm from LBC to motor pump set with required all labour and required lunks and nut bolts etc. |
| 84 | Providing and fitting of 100 m.m. dia. Flexible heavy pvc pipe for connection between HDPE pipe and submerssible moter pump set at U/S of lakhunder dam. |
| 85 | Lalour only for dismantling of induction or submersible motor pump set with suction and delavery pipes, foot valve etc. i/c transportation of above material from site of work to intake with loading and unloading complete. |
| 86 | Removing and folding of armod cable and stacking properly at intake store i/c all labour ,transportation ,loading unloading etc .complete. |
| 87 | Providing and fitting of 150/100 mm dia.cast iron flanged footvalve for suction pipe of induction motor pump set. Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Tender Published
Tender notice published.
CompletedBid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 11 daysBid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 13 daysTender Documents
Download All (ZIP) ↓We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender