Tender For special Repair To Drains,Parapet Wall Along Roadside Near Firing Range, Provn Of Chequered Tile Pathway From Bldg No P-265 (Amn Store) Complex To Nepal Tekri Det Interconnected With Badminton Court And Volleyball Court Of 23 Weu, Provn Of
Tender Overview
Project Description
Tender for special Repair To Drains,Parapet Wall Along Roadside Near Firing Range, Provn Of Chequered Tile Pathway From Bldg No P-265 (Amn Store) Complex To Nepal Tekri Det Interconnected With Badminton Court And Volleyball Court Of 23 Weu, Provn Of 35 X Geyser (25
Corrigendum
| Sr No | Corrigendum Date | Corrigendum | Type | New Submission Date |
|---|---|---|---|---|
| 1 | 06-Aug-2026 | CorrigendumNo1 | BOQ | 18-Aug-2026 |
| 2 | 18-Aug-2026 | Bid Auto Extn Corrigendum | Bid Auto Extn Corrigendum | 25-Aug-2026 |
BOQ
| Sl. No. | Item Description |
| 1 | Demolition of cement concrete (unreinforced) in ground floors and pavings not exc 15cm thickness (below or above ground level) |
| 2 | M&L PCC ( 1:4:8) D-2, using 40mm graded stone aggregate in fdn.,filling and mass concrete |
| 3 | M & L for PCC ( 1:2:4) type B-1, using 20mm graded stone aggregate in cement concrete in surface channels and drains |
| 4 | Extra for forming fair finished drain or channel 30 cm inner girth in cement complete all as specified and directed. concrete, using ex- tra cement, including forms, moulds, mitred/stopped ends etc complete all as specified and directed. |
| 5 | Demolition brick work or stone/ boulder masonery built in cement mortar including all quoins , pillars etc complete all as specified and directed. |
| 6 | M&L for brick work using sub class ‘B’ old size bricks, straight or curved on plan exceeding 6m mean radius, built in CM (1:6) |
| 7 | M&L for rendering 15 mm thick on concrete masonry surface in cement mortar 1:4 and finished even & smooth without using extra cement, complete all as spd and directed. |
| 8 | Surface dressing n exc 15 cm deep in hard/dense soil |
| 9 | Removing excavated material n exc. 50m and depositing wheredirected at a level n exc. 1.5 m above the starting point |
| 10 | M & L for Hard core of broken stone/boulders, broken to gauge n exc 63mm |
| 11 | M&L for 75mm thick plain cement concrete 1:4:8, type D2 (using 40 mm graded stone aggregate) as in sub base to flooring, complete all as specified & directed by Engr-in-charge. |
| 12 | M&L for Chequered cement concrete tiles 30cm x 30cm x 15-20mm thick, set, jointed and pointed in neat cement slurry in floors with grey cement and pigment |
| 13 | Providing and laying 80mm thick factory made chamfered edge cement concrete paver block of M-30 grade with approved colour, design & pattern as in footpath, parks, lawns, drive ways or light traffic parking etc., of required strength, thickness & size/ shape, made by table vibratory method using PU mould, laid in required colour & pattern over and including 50mm thick compacted bed of coarse sand, compacting and proper embedding/ laying of inter locking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with fine sand and cutting of paver block as per required size and pattern, finishing and sweeping extra sand; complete. |
| 14 | Providing cement concrete Type B1 1:2:4 (20 mm graded in roof kerbs or mud stops, rounded or chamfered on edgesin lintels upto 1.5m clear span, cills, steps; seismic and other similar bands, plinth courses, string courses, lacing courses, parapets and railings upto 60 cm in height, copings, kneelers, apex stones, bed plates, kerbs not provided for water troughs and the like including weathering, slightly rounded or chamfered angles and throating, as directed |
| 15 | M & L for sub main wiring PVC conduit concealed type with 2 runs of 4 Sq.mm for phase, neutral and 4 Sq.mm for earth continuity PVC insulated unsheathed cable (FR-LSH) grade with copper conductor single core multi stranded 1100V grade confirming to IS - 694 drawn through and including 25mm dia concealed PVC conduit (Heavy grade as per IS - 9537, Part - III) including conduit including PVC conduit accessories not less than 20mm dia including conduit accessories , junction boxes etc., all as directed. NOTE:- 2 Runs of 4 Sqmm + 1 run of 4 Sqmm cable, 1 run of PVC conduit shall be measured as 1 RM. |
| 16 | S & F point wiring for one 15 Amp socket outlet point (independent point), controlled by one, one way switch with 2.50 sqmm size PVC insulated unsheathed 1100 volts grade single core (multi-stranded) copper conductor cable (FR-LSH) drawn into and including medium grade PVC conduit concealed (not less than 20 mm dia) all necessary fittings and accessories fixed concealed (including chase cutting in brick/stone masonery wall for fixing conduit and plastering the external surfaces and matching the same with existing suface) and sunk cast iron and covered with 3 mm thick plastic laminated bakelite sheet cover fixed with brass screws and cup washers including one continuous run of PVC insulated (green colour) 2.50 sqmm size copper conductor cable as in earth wire |
| 17 | S&F sheet metal enclosure single pole and neutral with a two pin and earth plug and socket complete with one single pole MCB 240 Volts 20 Amps and one independent 15 A switch for switching the geyser ON/OFF independently complete all as specified and directed. |
| 18 | S&F sheet metal enclosure for DBs(double door type) single pole and neutral 2 way without busbar including blacking plate as required , 240 volts fixed complete all as specified and directed. |
| 19 | S & F MCB SPN, 240 V 32 Ampere, rupturing capacity 10 KA, 'B curve type complete all as spcified and directed. |
| 20 | Supply and fixing Geyser 25 Ltr Capacity,having SS tank, BEE five star rating with Digital Temperature Display & heating element upto 2 KW, ISI mark, with all accessories such as safety valve, thermostate, NRV, connection piece etc, and making good as per existing surface Complete all as specified and directed. |
| 21 | S/F GI water tubing medium grade, galvanised with all GI fittings (such as bends,elbows, tees, conectors, short pieces, back nuts, unions, caps & plugs etc)laid in trenches/on surface including connection with existing storage tank, cutttting, threading and testing complete all as specified and directed of the following sizes:- (a) 15 mm bore |
| 22 | Supply and fixing in stop valves, cast copper alloy 15 mm dia fancy type, chromium plated screwed down, high pressure with crutch or butterfly handle, screwed both ends for iron pipe or for unions |
| 23 | Supply and fixing 15mm bore bib taps, cast copper alloy with crutch or butterfly, handle, screwed down screwed for iron pipe or brass ferrul and fixed complete all as specified and directed. |
| 24 | S & F 450 mm long PVC connection 15mm size with PTMT nuts for cold and hot water complete all as specified. |
| 25 | S&F in repair sheet metal enclosure for DBs(double door type) single pole and neutral 4 way including blacking platge as required with 200 Amps rated bus bar, 240 volts fixed complete all as specified and directed . |
| 26 | Supply,fix, testing and commissioning of commercial type auto clean matt glass filterless chimney with inverter technology, BLDC motor 90cm 1600 m^3/h -(CH6074MGAC) made out of stainless steel including exhaust duct of required size and length, suitable for all kind of cooking stove/furnace or any other cooking appliances used in daily cooking. The chimney should be efficient and silent working and must be mounted as per site requirement i.e. ceiling(centre) mount or wall mount and must be capable of removing and absorbing all kind of smoke,fumes,steam,odor and oil from the cook house. The quoted shall include all kind of addition/alteration civil work including plastering, PCC and brick work reqd to install the chimney at the site. |
| 27 | Supply and Installation of fully autonomous,CPRI tested Early Streamer Emission Lightning Conductor (ESELC)with (gain in triggering time)of minimum of 20 us,radius of protection 37 meters in level 1 protection zone when installed on 5 meter mast along with other accessories for installing ESELC on the roof top of the Building/tower for the protection of the building/structure from direct lightning strikes.Complete all as specified and directed at NFS Nainital & Chaubattia. Make :-Tercel, Model Tz20 or equivalent make. |
| 28 | Supply and laying of 70 Sqmm copper flexible wires as down conductor from air terminal to the earth test link installed on the wall of the building 2 mtrs above the ground..Complete all as specified and directed at NFS Nainital & Chaubattia |
| 29 | Supply and installation of lightning transient event counter resettable 6 digit LCD display with in built lithium battery in IP67vrating enclosure with transparent lid, mounting arrangements etc,as required..Complete all as specified and directed at NFS Nainital & Chaubattia |
| 30 | Supply and laying of 25x3 mm Copper strip from Earth Test link to the Earth pit through 40mm B class GI pipe.Complete all as specified and directed at NFS Nainital & Chaubattia |
| 31 | Providing & creating of CPRI Tested earth pits material using ISOGEL earth enhanced compound of 20 kgs, ISOROD advanced chemical earth rod made with copper tube of 2.5\\" dia, 8 fit long,1.6 mm thick installed vertically or horizontally as per the side condition complete with glanges bends top cover heavy duty plastic inspection chamber including excavation and refilling etc as required..Complete all as specified and directed at NFS Nainital & Chaubattia. Make:-Tercel, Australia or equivalent make. Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Tender Published
Tender notice published.
CompletedCorrigendum-1 Issued
Clarifications on tender conditions and amendments issued.
CompletedCorrigendum-2 Issued
Clarifications on tender conditions and amendments issued.
Upcoming · 1 dayBid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 1 dayBid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 8 daysTender Documents
Download All (ZIP) ↓We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender