Housing Urban and Rular Development Government Departments Closing in 6 days TDR #56694283

Tender For Design, Build, Construct And Commission Of 2 (Two) Sewage Treatment Plants Along With Co-Treatment Of Faecal Sludge / Septage With 5 Years Of Operation And Maintenance In Ziro Ulb Of Arunachal Pradesh

Issued by Government Departments · Lower Subansiri, Arunachal Pradesh
Tender Value
Ref. Documents
Estimated cost
Bid Submission
18 Aug 2026
6 days left
EMD
25.44 Lakhs
Bank guarantee accepted
Document Fee
10000
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Lower Subansiri → Arunachal Pradesh
EMD Exemption
Not Available
Quantity
Not Available

Project Description

Tender for Design, Build, Construct And Commission Of 2 (Two) Sewage Treatment Plants Along With Co-Treatment Of Faecal Sludge / Septage With 5 Years Of Operation And Maintenance In Ziro Ulb Of Arunachal Pradesh

BOQ

Name of Work:- Design, Build, Construct and Commission of 2 (Two) Sewage Treatment Plants along with Co-treatment of Faecal sludge / septage with 5 years of Operation and Maintenance in Ziro ULB of Arunachal Pradesh
Sl. No. Item Description
1Construction of RCC elevated Platform for screen channel and Grit Chamber
2Earth work in excavation in foundation and trenches etc. in all kinds of soil (excluding soil containing 50% or more of shingle or small size boulders upto 30 cm size, saturated soil and rock) lift upto 1.50m and stacking the excavated soil not more than 3m clear from the edge of the excavation and returning the stacked soil in 15 cm layers, when required into plinth sides of foundation etc. consolidating each deposited layer by arming and watering of all surplus soil as directed within a lead of 50m in all types of soils for footings
3Earth work in excavation in foundation and trenches etc. in all kinds of soil (excluding soil containing 50% or more of shingle or small size boulders upto 30 cm size, saturated soil and rock) lift upto 1.50m and stacking the excavated soil not more than 3m clear from the edge of the excavation and returning the stacked soil in 15 cm layers, when required into plinth sides of foundation etc. consolidating each deposited layer by arming and watering of all surplus soil as directed within a lead of 50m 10% of the Total Qty
4Filling with sand including watering, ramming, consolidating and dressing complete.Below CC bed Below CC bed
5Providing and laying in foundations and plinth cement concrete 1 : 4 : 8 (1 cement : 4 coarse sand : 8 graded stone aggregate 40 mm nominal size) excluding the cost of centring and shuttering.CC Bed
6Reinforced concrete work in foundations, footings, bases of columns etc. and mass concrete excluding cost of centring, shuttering and reinforcement in : a) M20 (1 cement : 1.5 coarse sand : 3 stone aggregate 20 mm nominal size).Footings
7Reinforced concrete work in foundations, footings, bases of columns etc. and mass concrete excluding cost of centring, shuttering and reinforcement in : a) M20 (1 cement : 1.5 coarse sand : 3 stone aggregate 20 mm nominal size).Pedastal
8Reinforcement cement concrete work in columns, pillars, piers, abutments, post and struts etc up to floor two level including finishing and plastering the exposed surface with cement mortar 1 : 3 (1 cement : 3 fine sand) of thickness not exceeding 6 mm to give a smooth and even surface but exluding cost of centring, shuttering and reinforcement.a) M20 (1 cement : 1.5 coarse sand : 3 stone aggregate 20 mm nominal size).Columns upto GLColumns Above GL
9Reinforced cement concrete work in lintels, beams and bresumers up to floor two level including finishing and plastering the exposed surface with cement mortar 1 : 3 (1cement : 3 fine sand) of thickness not exceeding 6 mm to give a smooth and even surface but excluding cost of centering, shuttering and reinforcement.a) M20 (1 cement : 1.5 coarse sand : 3 stone aggregate 20 mm nominal size).Plinth BeamBracing Tie Beam @ 4m heightRoof Beam
10Reinforced cement concrete in suspended floors, roofs, landings and balconies upto floor two level including finishing and plastering the exposed surface with cement mortar 1 : 3 (1 cement : 3 fine sand) of thickness not exceeding 6 mm to give a smooth and even surface but excluding cost of centring and shuttering and reinforcement with M20 (1 cement : 1.5 coarse sand : 3 stone aggregate 20 mm nominal size).Roof Slab
11Centring and shuttering including strutting, propping etc and removal of form work for a) Foundation, footings, bases of columns etc. and mass concreteCC Bed FootingsPedastal
12Centring and shuttering including strutting, propping etc and removal of form work for e) Column, pillars, posts and struts etc.Columns upto GLColumns Above GL
13Centring and shuttering including strutting, propping etc and removal of form work for d) Lintels, beams, girders, bressumers and cantilevers etc.Roof BeamRoof Beam BottomRoof Beam Sides
14Centring and shuttering including strutting, propping etc and removal of form work forc) Suspended floors, roofs, landings shelves and their supports, balconies and chajjas (3.5 m height).Roof SlabRoof BottomRoof Sides
15Reinforcement of RCC work including bending, binding and placing in position complete.b) Tar/TMT steelFootingsPedastalColumns upto GLColumns Above GLPlinth BeamBracing Tie Beam @ 4m heightRoof BeamRoof Slab
16Steel work welded in built up sections/ framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required.b) In gratings, frames, guard bar, ladder, railings, brackets, gates and similar worksfor Lader
17Construction of RCC channel for Grid Chamber Fine Screen & Medium Screen
18Reinforced cement concrete in walls (any thickness) including attached pillasters,buttresses, plinth and string course, fillets etc from top of foundation up to floor two level including finishing and plastering the exposed surfaces with cement mortar 1 : 3 (1 cement : 3 fine sand) of thickness not exceeding 6 mm to give a smooth and even surface excluding cost of centring, shuttering and reinforcement in : a) M20 (1 cement : 1.5 corase sand : 3 stone aggregate 20 mm nominal size)RCC Walls
19Centring and shuttering including strutting, propping etc and removal of form work for b) Walls (any thickness) including attached pilasters, buttresses, plinth and string courses etc.RCC Walls
20Reinforcement of RCC work including bending, binding and placing in position complete.b) Tar/TMT steelReiforcement in BaseReinforcement of RCC Walls
2125 Providing and fixing stainless steel ( Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners , stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in-charge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.).Coarse ScreenWeight of SS Coarse Screen in - Kg/SqmMedium Screen Weight of SS Medium Screen in - Kg/SqmTotal Weight of Coarse & Medium Screen
22Construction of RCC Grit Chamber
23Reinforced cement concrete in walls (any thickness) including attached pillasters,buttresses, plinth and string course, fillets etc from top of foundation up to floor two level including finishing and plastering the exposed surfaces with cement mortar 1 : 3 (1 cement : 3 fine sand) of thickness not exceeding 6 mm to give a smooth and even surface excluding cost of centring, shuttering and reinforcement in : a) M20 (1 cement : 1.5 corase sand : 3 stone aggregate 20 mm nominal size)RCC Walls
24Centring and shuttering including strutting, propping etc and removal of form work for b) Walls (any thickness) including attached pilasters, buttresses, plinth and string courses etc.RCC Walls
25Reinforcement of RCC work including bending, binding and placing in position complete.b) Tar/TMT steelReiforcement in BaseReinforcement of RCC Walls
26Construction of RCC Primary Settling Tank
27Earth work in excavation in foundation and trenches etc. in all kinds of soil (excluding soil containing 50% or more of shingle or small size boulders upto 30 cm size, saturated soil and rock) lift upto 1.50m and stacking the excavated soil not more than 3m clear from the edge of the excavation and returning the stacked soil in 15 cm layers, when required into plinth sides of foundation etc. consolidating each deposited layer by arming and watering of all surplus soil as directed within a lead of 50m % of the above Quantity.
28Earth work in excavation in foundation and trenches etc. in all kinds of soil (excluding soil containing 50% or more of shingle or small size boulders upto 30 cm size, saturated soil and rock) lift upto 1.50m and stacking the excavated soil not more than 3m clear from the edge of the excavation and returning the stacked soil in 15 cm layers, when required into plinth sides of foundation etc. consolidating each deposited layer by arming and watering of all surplus soil as directed within a lead of 50m % of the above Quantity.
29Filling with sand including watering, ramming, consolidating and dressing complete.Sand Bed below CC bedFor FootingsFor walls
30Providing and laying in foundations and plinth cement concrete 1 : 4 : 8 (1 cement : 4 coarse sand : 8 graded stone aggregate 40 mm nominal size) excluding the cost of centring and shuttering.CC BedFor FootingsFor walls
31Reinforced concrete work in foundations, footings, bases of columns etc. and mass concrete excluding cost of centring, shuttering and reinforcement in : a) M20 (1 cement : 1.5 coarse sand : 3 stone aggregate 20 mm nominal size).FootingsPedestal For Base slab
32Reinforcement cement concrete work in columns, pillars, piers, abutments, post and struts etc up to floor two level including finishing and plastering the exposed surface with cement mortar 1 : 3 (1 cement : 3 fine sand) of thickness not exceeding 6 mm to give a smooth and even surface but exluding cost of centring, shuttering and reinforcement.a) M20 (1 cement : 1.5 coarse sand : 3 stone aggregate 20 mm nominal size).Columns upto GLColumns Above GL
33Reinforced cement concrete in walls (any thickness) including attached pillasters,buttresses, plinth and string course, fillets etc from top of foundation up to floor two level including finishing and plastering the exposed surfaces with cement mortar 1 : 3 (1 cement : 3 fine sand) of thickness not exceeding 6 mm to give a smooth and even surface excluding cost of centring, shuttering and reinforcement in : a) M20 (1 cement : 1.5 corase sand : 3 stone aggregate 20 mm nominal size)For RCC walls Circuferance length
34Reinforced cement concrete work in lintels, beams and bresumers up to floor two level including finishing and plastering the exposed surface with cement mortar 1 : 3 (1cement : 3 fine sand) of thickness not exceeding 6 mm to give a smooth and even surface but excluding cost of centering, shuttering and reinforcement.a) M20 (1 cement : 1.5 coarse sand : 3 stone aggregate 20 mm nominal size).Plinth BeamRoof Beam
35Reinforced cement concrete in suspended floors, roofs, landings and balconies upto floor two level including finishing and plastering the exposed surface with cement mortar 1 : 3 (1 cement : 3 fine sand) of thickness not exceeding 6 mm to give a smooth and even surface but excluding cost of centring and shuttering and reinforcement with M20 (1 cement : 1.5 coarse sand : 3 stone aggregate 20 mm nominal size). For inspection track along the wall
36Centring and shuttering including strutting, propping etc and removal of form work for a) Foundation, footings, bases of columns etc. and mass concreteCC BedFootingsPedestal
37Centring and shuttering including strutting, propping etc and removal of form work for d) Lintels, beams, girders, bressumers and cantilevers etc.Plinth Beam BottomPlinth Beam Sides
38Centring and shuttering including strutting, propping etc and removal of form work forc) Suspended floors, roofs, landings shelves and their supports, balconies and chajjas (3.5 m height). For inspection track along the wallRoof BottomRoof Sides
39Centring and shuttering including strutting, propping etc and removal of form work for b) Walls (any thickness) including attached pilasters, buttresses, plinth and string courses etc.For Base slab For RCC walls
40Extra for shuttering in circular work. Add 20% of the rate of respective item of centring and shuttering.
416 mm cement plaster 1 : 3 (1 cement : 3 fine sand) finished with a floating coat of neat cement and thick coat of lime wash on top of walls when dry for bearing of RCC slabs and beams.inner side of the structure
42Applying Two coats of Corroseal Epoxy Resin based Coating in one base coat and One top coats over the thoroughly prepared interior surfaces as directed by departmental officers, with each coat not exceeding 60 microns in dry film thickness and total film thickness to 240 microns including cost and conveyance of all materials to site, all labour charges ,curing and all other incidental charges etc complete for finished item of workAs per plastering Qty (Q)
43Providing and fixing of FRP Hand railings with Vertical Post of size 50 x 50x 5 mm speacing of at every 1000mm c/c with 1000mm height,and Middle Tube 25mm x 30mm, Top rail of 65 x 45 mm. Resin Polymer +UV Grade with Hardware : SS304 (As Per design), Yellow color or other as per approved. Including cost of all materials,fittings, machinery, labour, etc., finsished item of work as per direction of engineer incharge.on both sides of the inspection Walkway slab
44Reinforcement of RCC work including bending, binding and placing in position complete.b) Tar/TMT steelBase slabWallsSlab
45Construction of RCC Bio Tower
46Earth work in excavation in foundation and trenches etc. in all kinds of soil (excluding soil containing 50% or more of shingle or small size boulders upto 30 cm size, saturated soil and rock) lift upto 1.50m and stacking the excavated soil not more than 3m clear from the edge of the excavation and returning the stacked soil in 15 cm layers, when required into plinth sides of foundation etc. consolidating each deposited layer by arming and watering of all surplus soil as directed within a lead of 50m % of the above Quantity.
47Earth work in excavation in foundation and trenches etc. in all kinds of soil (excluding soil containing 50% or more of shingle or small size boulders upto 30 cm size, saturated soil and rock) lift upto 1.50m and stacking the excavated soil not more than 3m clear from the edge of the excavation and returning the stacked soil in 15 cm layers, when required into plinth sides of foundation etc. consolidating each deposited layer by arming and watering of all surplus soil as directed within a lead of 50m % of the above Quantity.
48Filling with sand including watering, ramming, consolidating and dressing complete.Sand Bed below CC bedFor FootingsFor walls
49Providing and laying in foundations and plinth cement concrete 1 : 4 : 8 (1 cement : 4 coarse sand : 8 graded stone aggregate 40 mm nominal size) excluding the cost of centring and shuttering.CC BedFor FootingsFor walls
50Reinforced concrete work in foundations, footings, bases of columns etc. and mass concrete excluding cost of centring, shuttering and reinforcement in : a) M20 (1 cement : 1.5 coarse sand : 3 stone aggregate 20 mm nominal size).FootingsPedestal For Base slab
51Reinforcement cement concrete work in columns, pillars, piers, abutments, post and struts etc up to floor two level including finishing and plastering the exposed surface with cement mortar 1 : 3 (1 cement : 3 fine sand) of thickness not exceeding 6 mm to give a smooth and even surface but exluding cost of centring, shuttering and reinforcement.a) M20 (1 cement : 1.5 coarse sand : 3 stone aggregate 20 mm nominal size).Columns upto GLColumns Above GL
52Reinforced cement concrete in walls (any thickness) including attached pillasters,buttresses, plinth and string course, fillets etc from top of foundation up to floor two level including finishing and plastering the exposed surfaces with cement mortar 1 : 3 (1 cement : 3 fine sand) of thickness not exceeding 6 mm to give a smooth and even surface excluding cost of centring, shuttering and reinforcement in : a) M20 (1 cement : 1.5 corase sand : 3 stone aggregate 20 mm nominal size)For RCC walls side length
53Reinforced cement concrete work in lintels, beams and bresumers up to floor two level including finishing and plastering the exposed surface with cement mortar 1 : 3 (1cement : 3 fine sand) of thickness not exceeding 6 mm to give a smooth and even surface but excluding cost of centering, shuttering and reinforcement.a) M20 (1 cement : 1.5 coarse sand : 3 stone aggregate 20 mm nominal size).Grid Tie Beam Spacing @ 0.9m C/C at 1.2m heightRoof Beam
54Reinforced cement concrete in suspended floors, roofs, landings and balconies upto floor two level including finishing and plastering the exposed surface with cement mortar 1 : 3 (1 cement : 3 fine sand) of thickness not exceeding 6 mm to give a smooth and even surface but excluding cost of centring and shuttering and reinforcement with M20 (1 cement : 1.5 coarse sand : 3 stone aggregate 20 mm nominal size). For inspection track along the Roof beam
55Centring and shuttering including strutting, propping etc and removal of form work for a) Foundation, footings, bases of columns etc. and mass concreteCC BedFootingsPedestal
56Centring and shuttering including strutting, propping etc and removal of form work for d) Lintels, beams, girders, bressumers and cantilevers etc.Grid Tie Beam Spacing @ 0.9m C/C at 1.2m heightRoof Beam BottomRoof Beam Sides
57Centring and shuttering including strutting, propping etc and removal of form work forc) Suspended floors, roofs, landings shelves and their supports, balconies and chajjas (3.5 m height). For inspection track along the Roof beamRoof BottomRoof Sides
58Centring and shuttering including strutting, propping etc and removal of form work for b) Walls (any thickness) including attached pilasters, buttresses, plinth and string courses etc.For Base slab For RCC walls
59Extra for shuttering in circular work. Add 20% of the rate of respective item of centring and shuttering.
606 mm cement plaster 1 : 3 (1 cement : 3 fine sand) finished with a floating coat of neat cement and thick coat of lime wash on top of walls when dry for bearing of RCC slabs and beams.inner side of the structure
61Applying Two coats of Corroseal Epoxy Resin based Coating in one base coat and One top coats over the thoroughly prepared interior surfaces as directed by departmental officers, with each coat not exceeding 60 microns in dry film thickness and total film thickness to 240 microns including cost and conveyance of all materials to site, all labour charges ,curing and all other incidental charges etc complete for finished item of workAs per plastering Qty (Q)
62Providing and fixing of FRP Hand railings with Vertical Post of size 50 x 50x 5 mm speacing of at every 1000mm c/c with 1000mm height,and Middle Tube 25mm x 30mm, Top rail of 65 x 45 mm. Resin Polymer +UV Grade with Hardware : SS304 (As Per design), Yellow color or other as per approved. Including cost of all materials,fittings, machinery, labour, etc., finsished item of work as per direction of engineer incharge.on both sides of the inspection Walkway slab
63Reinforcement of RCC work including bending, binding and placing in position complete.b) Tar/TMT steelBase slabWallsSlab
64Construction of RCC Secondary Settling Tank
65Earth work in excavation in foundation and trenches etc. in all kinds of soil (excluding soil containing 50% or more of shingle or small size boulders upto 30 cm size, saturated soil and rock) lift upto 1.50m and stacking the excavated soil not more than 3m clear from the edge of the excavation and returning the stacked soil in 15 cm layers, when required into plinth sides of foundation etc. consolidating each deposited layer by arming and watering of all surplus soil as directed within a lead of 50m -% of the above Quantity.
66Earth work in excavation in foundation and trenches etc. in all kinds of soil (excluding soil containing 50% or more of shingle or small size boulders upto 30 cm size, saturated soil and rock) lift upto 1.50m and stacking the excavated soil not more than 3m clear from the edge of the excavation and returning the stacked soil in 15 cm layers, when required into plinth sides of foundation etc. consolidating each deposited layer by arming and watering of all surplus soil as directed within a lead of 50m -% of the above Quantity.
67Filling with sand including watering, ramming, consolidating and dressing complete.-Filling with sand including watering, ramming, consolidating and dressing complete.-Sand Bed below CC bed-For Footings-For walls
68Providing and laying in foundations and plinth cement concrete 1 : 4 : 8 (1 cement : 4 coarse sand : 8 graded stone aggregate 40 mm nominal size) excluding the cost of centring and shuttering.-CC Bed-For Footings-For walls
69Reinforced concrete work in foundations, footings, bases of columns etc. and mass concrete excluding cost of centring, shuttering and reinforcement in : a) M20 (1 cement : 1.5 coarse sand : 3 stone aggregate 20 mm nominal size).-Footings-Pedestal -For Base slab
70Reinforcement cement concrete work in columns, pillars, piers, abutments, post and struts etc up to floor two level including finishing and plastering the exposed surface with cement mortar 1 : 3 (1 cement : 3 fine sand) of thickness not exceeding 6 mm to give a smooth and even surface but exluding cost of centring, shuttering and reinforcement.a) M20 (1 cement : 1.5 coarse sand : 3 stone aggregate 20 mm nominal size).-Columns upto GL-Columns Above GL
71Reinforced cement concrete in walls (any thickness) including attached pillasters,buttresses, plinth and string course, fillets etc from top of foundation up to floor two level including finishing and plastering the exposed surfaces with cement mortar 1 : 3 (1 cement : 3 fine sand) of thickness not exceeding 6 mm to give a smooth and even surface excluding cost of centring, shuttering and reinforcement in : a) M20 (1 cement : 1.5 corase sand : 3 stone aggregate 20 mm nominal size)-For RCC walls -Circuferance length
72Reinforced cement concrete work in lintels, beams and bresumers up to floor two level including finishing and plastering the exposed surface with cement mortar 1 : 3 (1cement : 3 fine sand) of thickness not exceeding 6 mm to give a smooth and even surface but excluding cost of centering, shuttering and reinforcement.a) M20 (1 cement : 1.5 coarse sand : 3 stone aggregate 20 mm nominal size).-Plinth Beam-Roof Beam
73Reinforced cement concrete in suspended floors, roofs, landings and balconies upto floor two level including finishing and plastering the exposed surface with cement mortar 1 : 3 (1 cement : 3 fine sand) of thickness not exceeding 6 mm to give a smooth and even surface but excluding cost of centring and shuttering and reinforcement with M20 (1 cement : 1.5 coarse sand : 3 stone aggregate 20 mm nominal size).- For inspection track along the wall
74Centring and shuttering including strutting, propping etc and removal of form work for a) Foundation, footings, bases of columns etc. and mass concrete-CC Bed-Footings-Pedestal
75Centring and shuttering including strutting, propping etc and removal of form work for d) Lintels, beams, girders, bressumers and cantilevers etc.-Plinth Beam Bottom-Plinth Beam Sides
76Centring and shuttering including strutting, propping etc and removal of form work forc) Suspended floors, roofs, landings shelves and their supports, balconies and chajjas (3.5 m height).- For inspection track along the wall-Roof Bottom-Roof Sides
77Centring and shuttering including strutting, propping etc and removal of form work for b) Walls (any thickness) including attached pilasters, buttresses, plinth and string courses etc.-For Base slab -For RCC walls
78Extra for shuttering in circular work. Add 20% of the rate of respective item of centring and shuttering.
796 mm cement plaster 1 : 3 (1 cement : 3 fine sand) finished with a floating coat of neat cement and thick coat of lime wash on top of walls when dry for bearing of RCC slabs and beams.-inner side of the structure
80Applying Two coats of Corroseal Epoxy Resin based Coating in one base coat and One top coats over the thoroughly prepared interior surfaces as directed by departmental officers, with each coat not exceeding 60 microns in dry film thickness and total film thickness to 240 microns including cost and conveyance of all materials to site, all labour charges ,curing and all other incidental charges etc complete for finished item of work-As per plastering Qty (Q)
81Providing and fixing of FRP Hand railings with Vertical Post of size 50 x 50x 5 mm speacing of at every 1000mm c/c with 1000mm height,and Middle Tube 25mm x 30mm, Top rail of 65 x 45 mm. Resin Polymer +UV Grade with Hardware : SS304 (As Per design), Yellow color or other as per approved. Including cost of all materials,fittings, machinery, labour, etc., finsished item of work as per direction of engineer incharge.-on both sides of the inspection Walkway slab
82Reinforcement of RCC work including bending, binding and placing in position complete.b) Tar/TMT steel-Base slab-Walls-Slab
83Construction of RCC channel for Fecal sludge collection Chamber Fine Screen & Medium Screen
84Earth work in excavation in foundation and trenches etc. in all kinds of soil (excluding soil containing 50% or more of shingle or small size boulders upto 30 cm size, saturated soil and rock) lift upto 1.50m and stacking the excavated soil not more than 3m clear from the edge of the excavation and returning the stacked soil in 15 cm layers, when required into plinth sides of foundation etc. consolidating each deposited layer by arming and watering of all surplus soil as directed within a lead of 50m -in all types of soils
85Earth work in excavation in foundation and trenches etc. in all kinds of soil (excluding soil containing 50% or more of shingle or small size boulders upto 30 cm size, saturated soil and rock) lift upto 1.50m and stacking the excavated soil not more than 3m clear from the edge of the excavation and returning the stacked soil in 15 cm layers, when required into plinth sides of foundation etc. consolidating each deposited layer by arming and watering of all surplus soil as directed within a lead of 50m -10% of the Total Qty
86Filling with sand including watering, ramming, consolidating and dressing complete.-Below CC bed for RCC drain
87Providing and laying in foundations and plinth cement concrete 1 : 4 : 8 (1 cement : 4 coarse sand : 8 graded stone aggregate 40 mm nominal size) excluding the cost of centring and shuttering.-CC Bed for RCC Drain
88Reinforced concrete work in foundations, footings, bases of columns etc. and mass concrete excluding cost of centring, shuttering and reinforcement in : a) M20 (1 cement : 1.5 coarse sand : 3 stone aggregate 20 mm nominal size).-Foundation Base Slab
89Reinforced cement concrete in walls (any thickness) including attached pillasters,buttresses, plinth and string course, fillets etc from top of foundation up to floor two level including finishing and plastering the exposed surfaces with cement mortar 1 : 3 (1 cement : 3 fine sand) of thickness not exceeding 6 mm to give a smooth and even surface excluding cost of centring, shuttering and reinforcement in : a) M20 (1 cement : 1.5 corase sand : 3 stone aggregate 20 mm nominal size)-RCC Walls
90Centring and shuttering including strutting, propping etc and removal of form work for a) Foundation, footings, bases of columns etc. and mass concrete-CC Bed for RCC Drain-Foundation Base Slab
91Centring and shuttering including strutting, propping etc and removal of form work for b) Walls (any thickness) including attached pilasters, buttresses, plinth and string courses etc.-RCC Walls
92Reinforcement of RCC work including bending, binding and placing in position complete.b) Tar/TMT steel-Reiforcement in Base-Reinforcement of RCC Walls
9325 Providing and fixing stainless steel ( Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners , stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in-charge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.).-Coarse Screen-Medium Screen
94Construction of RCC Fecal Sludge collection Chamber
95Earth work in excavation in foundation and trenches etc. in all kinds of soil (excluding soil containing 50% or more of shingle or small size boulders upto 30 cm size, saturated soil and rock) lift upto 1.50m and stacking the excavated soil not more than 3m clear from the edge of the excavation and returning the stacked soil in 15 cm layers, when required into plinth sides of foundation etc. consolidating each deposited layer by arming and watering of all surplus soil as directed within a lead of 50m -in all types of soils
96Earth work in excavation in foundation and trenches etc. in all kinds of soil (excluding soil containing 50% or more of shingle or small size boulders upto 30 cm size, saturated soil and rock) lift upto 1.50m and stacking the excavated soil not more than 3m clear from the edge of the excavation and returning the stacked soil in 15 cm layers, when required into plinth sides of foundation etc. consolidating each deposited layer by arming and watering of all surplus soil as directed within a lead of 50m -10% of the Total Qty
97Filling with sand including watering, ramming, consolidating and dressing complete.-Below CC bed for RCC Grit Chamber
98Providing and laying in foundations and plinth cement concrete 1 : 4 : 8 (1 cement : 4 coarse sand : 8 graded stone aggregate 40 mm nominal size) excluding the cost of centring and shuttering.-CC Bed for RCC Grit Chamber
99Reinforced concrete work in foundations, footings, bases of columns etc. and mass concrete excluding cost of centring, shuttering and reinforcement in : a) M20 (1 cement : 1.5 coarse sand : 3 stone aggregate 20 mm nominal size).-Foundation Base Slab
100Reinforced cement concrete in walls (any thickness) including attached pillasters,buttresses, plinth and string course, fillets etc from top of foundation up to floor two level including finishing and plastering the exposed surfaces with cement mortar 1 : 3 (1 cement : 3 fine sand) of thickness not exceeding 6 mm to give a smooth and even surface excluding cost of centring, shuttering and reinforcement in : a) M20 (1 cement : 1.5 corase sand : 3 stone aggregate 20 mm nominal size)-RCC Walls
101Centring and shuttering including strutting, propping etc and removal of form work for a) Foundation, footings, bases of columns etc. and mass concrete-CC Bed for RCC Grit Chamber-Foundation Base Slab
102Centring and shuttering including strutting, propping etc and removal of form work for b) Walls (any thickness) including attached pilasters, buttresses, plinth and string courses etc.-RCC Walls
103Reinforcement of RCC work including bending, binding and placing in position complete.b) Tar/TMT steel-Reiforcement in Base-Reinforcement of RCC Walls
104Construction of Chlorination Tank
105Earth work in excavation in foundation and trenches etc. in all kinds of soil (excluding soil containing 50% or more of shingle or small size boulders upto 30 cm size, saturated soil and rock) lift upto 1.50m and stacking the excavated soil not more than 3m clear from the edge of the excavation and returning the stacked soil in 15 cm layers, when required into plinth sides of foundation etc. consolidating each deposited layer by arming and watering of all surplus soil as directed within a lead of 50m -% of the above Quantity.
106Earth work in excavation in foundation and trenches etc. in all kinds of soil (excluding soil containing 50% or more of shingle or small size boulders upto 30 cm size, saturated soil and rock) lift upto 1.50m and stacking the excavated soil not more than 3m clear from the edge of the excavation and returning the stacked soil in 15 cm layers, when required into plinth sides of foundation etc. consolidating each deposited layer by arming and watering of all surplus soil as directed within a lead of 50m -% of the above Quantity.
107Filling with sand including watering, ramming, consolidating and dressing complete.-Sand Bed below CC bed
108Providing and laying in foundations and plinth cement concrete 1 : 4 : 8 (1 cement : 4 coarse sand : 8 graded stone aggregate 40 mm nominal size) excluding the cost of centring and shuttering.-CC Bed
109Reinforced concrete work in foundations, footings, bases of columns etc. and mass concrete excluding cost of centring, shuttering and reinforcement in : a) M20 (1 cement : 1.5 coarse sand : 3 stone aggregate 20 mm nominal size).-For Base slab
110Reinforced cement concrete in walls (any thickness) including attached pillasters,buttresses, plinth and string course, fillets etc from top of foundation up to floor two level including finishing and plastering the exposed surfaces with cement mortar 1 : 3 (1 cement : 3 fine sand) of thickness not exceeding 6 mm to give a smooth and even surface excluding cost of centring, shuttering and reinforcement in : a) M20 (1 cement : 1.5 corase sand : 3 stone aggregate 20 mm nominal size)-For RCC walls
111Reinforced concrete work in foundations, footings, bases of columns etc. and mass concrete excluding cost of centring, shuttering and reinforcement in : a) M20 (1 cement : 1.5 coarse sand : 3 stone aggregate 20 mm nominal size).-Top Slab-Deduct Manhole
112Centring and shuttering including strutting, propping etc and removal of form work for a) Foundation, footings, bases of columns etc. and mass concrete-CC Bed-For Base slab -For RCC walls
113Centring and shuttering including strutting, propping etc and removal of form work for b) Walls (any thickness) including attached pilasters, buttresses, plinth and string courses etc.-For RCC walls
1146 mm cement plaster 1 : 3 (1 cement : 3 fine sand) finished with a floating coat of neat cement and thick coat of lime wash on top of walls when dry for bearing of RCC slabs and beams.-Intternal Platering-External Plastering
115Applying Two coats of Corroseal Epoxy Resin based Coating in one base coat and One top coats over the thoroughly prepared interior surfaces as directed by departmental officers, with each coat not exceeding 60 microns in dry film thickness and total film thickness to 240 microns including cost and conveyance of all materials to site, all labour charges ,curing and all other incidental charges etc complete for finished item of work-As per plastering Qty (Q)
116Painting two or more coats with enamel paint of approved brand and manufacture in any shade on new work to give an even shade.-External Painting above GL
117Reinforcement of RCC work including bending, binding and placing in position complete.b) Tar/TMT steel-For Base slab -For RCC walls -Top Slab
118Construction of Office and Electrical Panel Room of Size 5.5m x3.0m
119Earth work in excavation in foundation and trenches etc. in all kinds of soil (excluding soil containing 50% or more of shingle or small size boulders upto 30 cm size, saturated soil and rock) lift upto 1.50m and stacking the excavated soil not more than 3m clear from the edge of the excavation and returning the stacked soil in 15 cm layers, when required into plinth sides of foundation etc. consolidating each deposited layer by arming and watering of all surplus soil as directed within a lead of 50m -in all types of soils
120Earth work in excavation in foundation and trenches etc. in all kinds of soil (excluding soil containing 50% or more of shingle or small size boulders upto 30 cm size, saturated soil and rock) lift upto 1.50m and stacking the excavated soil not more than 3m clear from the edge of the excavation and returning the stacked soil in 15 cm layers, when required into plinth sides of foundation etc. consolidating each deposited layer by arming and watering of all surplus soil as directed within a lead of 50m -in Hard rocky soils
121Earth work in excavation in foundation and trenches etc. in all kinds of soil (excluding soil containing 50% or more of shingle or small size boulders upto 30 cm size, saturated soil and rock) lift upto 1.50m and stacking the excavated soil not more than 3m clear from the edge of the excavation and returning the stacked soil in 15 cm layers, when required into plinth sides of foundation etc. consolidating each deposited layer by arming and watering of all surplus soil as directed within a lead of 50m -in all types of soils
122Earth work in excavation in foundation and trenches etc. in all kinds of soil (excluding soil containing 50% or more of shingle or small size boulders upto 30 cm size, saturated soil and rock) lift upto 1.50m and stacking the excavated soil not more than 3m clear from the edge of the excavation and returning the stacked soil in 15 cm layers, when required into plinth sides of foundation etc. consolidating each deposited layer by arming and watering of all surplus soil as directed within a lead of 50m -in Hard rocky soils
123Providing and laying cement concrete 1 : 3 : 6 (1 cement : 3 coarse sand : 6 graded stone aggregate 40 mm nominal size) excluding the cost of centring an shuttering in:a) Foundations and plinth-Columns Footings-for foundations of Basement-Flooring-Flooring of office room-Ramp portion
124Reinforced concrete work in foundations, footings, bases of columns etc. and mass concrete excluding cost of centring, shuttering and reinforcement in : a) M20 (1 cement : 1.5 coarse sand : 3 stone aggregate 20 mm nominal size).-Column footing.
125Reinforced concrete work in foundations, footings, bases of columns etc. and mass concrete excluding cost of centring, shuttering and reinforcement in : a) M20 (1 cement : 1.5 coarse sand : 3 stone aggregate 20 mm nominal size).-Pedastals
126Reinforced cement concrete work in lintels, beams and bresumers up to floor two level including finishing and plastering the exposed surface with cement mortar 1 : 3 (1cement : 3 fine sand) of thickness not exceeding 6 mm to give a smooth and even surface but excluding cost of centering, shuttering and reinforcement.a) M20 (1 cement : 1.5 coarse sand : 3 stone aggregate 20 mm nominal size).-Plinth Beam
127Reinforcement cement concrete work in columns, pillars, piers, abutments, post and struts etc up to floor two level including finishing and plastering the exposed surface with cement mortar 1 : 3 (1 cement : 3 fine sand) of thickness not exceeding 6 mm to give a smooth and even surface but exluding cost of centring, shuttering and reinforcement.a) M20 (1 cement : 1.5 coarse sand : 3 stone aggregate 20 mm nominal size).-Columns up to 3.66 Mts unsupported height above GL
128Reinforced cement concrete work in lintels, beams and bresumers up to floor two level including finishing and plastering the exposed surface with cement mortar 1 : 3 (1cement : 3 fine sand) of thickness not exceeding 6 mm to give a smooth and even surface but excluding cost of centering, shuttering and reinforcement.a) M20 (1 cement : 1.5 coarse sand : 3 stone aggregate 20 mm nominal size).-Lintals
129Reinforced cement concrete in chajjas exceeding 15mm in thickness upto floor two level including centring and shuttering complete but excluding the cost of reinforcement with M20 ( 1 cement: 1.5 coarse sand : 3 stone aggregate 20 mm nominal size).-RCC M20 for Sun shades of 0.60M width, 75mm th. at fixed end and 50mm th. at free end
130Reinforced cement concrete work in lintels, beams and bresumers up to floor two level including finishing and plastering the exposed surface with cement mortar 1 : 3 (1cement : 3 fine sand) of thickness not exceeding 6 mm to give a smooth and even surface but excluding cost of centering, shuttering and reinforcement.a) M20 (1 cement : 1.5 coarse sand : 3 stone aggregate 20 mm nominal size).-Roof Beams
131Reinforced cement concrete in suspended floors, roofs, landings and balconies upto floor two level including finishing and plastering the exposed surface with cement mortar 1 : 3 (1 cement : 3 fine sand) of thickness not exceeding 6 mm to give a smooth and even surface but excluding cost of centring and shuttering and reinforcement with M20 (1 cement : 1.5 coarse sand : 3 stone aggregate 20 mm nominal size).-Roof Slab - 125mm thick
132Coursed rubble masonry (first sort) with hard stone in foundations and plinth in cement mortar 1 : 6 (1 cement : 6 fine sand).-Ist Step below G.L(foundations)-2nd Step above GL(basement)
133Brick work with best available local bricks in foundations and plinth in cement mortar 1:6 (1 cement : 6 fine sand).-Right round the building
134Half brick masonry (with best available local bricks) in cement mortar 1:4 (1 cement : 4coarse sand) in foundation and plinth.-Partiton wall-Parapet wall
1356 mm cement plaster to ceiling 1 : 3 (1 cement : 3 fine sand).-to ceiling and bottom and sides of beams
13612 mm cement plaster 1 : 3 (1 cement : 3 fine sand).-Internal long walls-Internal short walls-Partiton wall
13715 mm cement plaster 1 : 3 (1 cement : 3 fine sand) on the rough side of single or half brick wall.-External long walls-External short walls-Sun shades on both faces-both sides of the parapet wall
138Colour washing such as green, blue or buff on new work (two or more coats) including abase coat of white washing with lime to give an even shade.-Qty as ceiling plastering-Qty as per Internal Plastering
139Colour washing such as green, blue or buff on new work (two or more coats) including abase coat or white washing with whiting to give an even shade.-Qty as external plastering
140Cement concrete flooring 1 : 2 : 4 (1 cement : 2 coarse sand : 4 graded stone shingle 20mm nominal size) finished with a floating coat of neat cement.b) 50 mm thick-office room
141Entry / Exit Door Shutters :- Providing and fixing 37 mm thick factory made PVC Doorshutter, styles and rails made of PVC hollow extruded printed and laminated section having overall dimension 115 mm x 37 mm with wall thickness 2 mm (± 0.2 mm) with inbuilt beading on one side, the styles and rails mitred cut and joint at corners by inserting 2 nos PVC profile reinforcement of size 75 mm x 200 mm long with cross section size of 28 mm x 30 mm having wall thickness 2 mm (± 0.2 mm). Styles, rails and reinforcements to be fusion welded together. Only hinge side vertical style to be einforced with PVC profile reinforcement in full length. Printed and laminated PVC lock rail of size 110 mm x 37 mm having wall thickness 2 mm (± 0.2 mm) to be welded horizontally with the vertical styles after inserting PVC profile reinforcement as in styles and rails, providing with PVC snap fit beading, panels of 100 x 20 mm printed & laminated and inserting 2 nos 6 mm dia bright steel rod horizontally with both side threaded and tightened with check nuts and washers complete, all as per manufacturer's specification and direction of engineer-in-charge.-Doors
142Window / Ventilator Shutters:- Providing and fixing factory made uPVC white colour casement/ casement cum fixed glazed windows comprising of uPVC multi chambered frame, sash and mullion (where ever required) extruded profiles duly reinforced with 1.60 ± 0.2 mm thick galvanized mild steel section made from roll forming process of required length (shape & size according to uPVC profile), uPVC extruded glazing beads of appropriate dimension, EPDM gasket, stainless steel (SS 304 grade) friction hinges,zinc alloy (white powder coated) casement handles, G.I fasteners 100 x 8 mm size for fixing frame to finished wall, plastic packers, plastic caps and necessary stainless steel screws etc. Profile of frame & sash shall be mitred cut and fusion welded at all corners,mullion (if required) shall be also fusion welded including drilling of holes for fixing hardware's and drainage of water etc. After fixing frame the gap between frame and adjacent finished wall shall be filled with weather proof silicon sealant over backer rod of required size and of approved quality, all complete as per approved drawing & direction of Engineer-in-Charge. (Single / double glass panes and silicon sealant shall be paid separately) -Windows
143Providing precast cement concrete jali M20 (1 cement : 1.5 coarse sand : 3 stone aggregate 20 mm nominal size) reinforced with 1.6 mm dia mild steel wire including,roughening, cleaning, fixing and finishing in cement mortar 1 : 3 (1 cement : 3 fine sand) etc complete upto floor two level excluding plastering of the jams, sills and soffits.a) 50 mm thick-
144Centring and shuttering including strutting, propping etc and removal of form work for a) Foundation, footings, bases of columns etc. and mass concrete-Column footing.-Pedastals-Plinth Beam
145Centring and shuttering including strutting, propping etc and removal of form work for e) Column, pillars, posts and struts etc.-Columns up to GL-Columns above GL up to plinth beam top level-Columns above plinth beam top level to slab top level-Columns Above slab level
146Centring and shuttering including strutting, propping etc and removal of form work for d) Lintels, beams, girders, bressumers and cantilevers etc.-over windows-Roof Beams
147Centring and shuttering including strutting, propping etc and removal of form work forc) Suspended floors, roofs, landings shelves and their supports, balconies and chajjas (3.5 m height).-Roof Slab - 125mm thick
148Reinforcement of RCC work including bending, binding and placing in position complete.
149Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m.-Basement
150Sanitory Charges
151Electrification Charges
152Providing and installation of Generator set
153Supply, Transportation, erection and commissioning (Excluding Foundation) of 3 Phase, 415, 50Hz, water cooled multi cylinder diesel generator set with alternator of - - - KVA/ - - - - - KW out put contineous rating directly coupled Engine and Alternator with guard and mounted on a common base plate of Robust construction and complete without control panel having IP-52 protection, Acoustic Enclosure as per CPCB norms , sound absorbing material, t to restrict sound level up to 75 dB up to 1 mtr distance and as per CPCB norms etc as per following specifications mentioned below. A. Alternator : Kirloskar / Stamford / Crompton Greaves / Leroy Somer make. The alternator of the output rating shall be 3 Phase, 415V, 50Hz, Ac , 0.8 P.F. lagging at 1500 RPM. The alternator is self excited, self regulated, and shall confirm to IS: 13364 of 1992 with regulation of +5% from no load to full load. degree of protections shall be IP21.B.Diesel Engine : Kirloskar / Cummins / Mahindra & Mahindra Diesel Engine start, developing suitable -------------- BHP output at 1500 RPM with mechanical / electronic governing so as to enable the alternator to give - - - - -KVA continuous output at 0.8 P.F. lagging at NTP conditions. The diesel engine shall be capable of providing 10% O/L for 1 Hr for every 11 Hrs of continuous running at full load. The engine with 1st filling of oil and Diesel etc. 01. Exhaust pipe of required size and length with insulation or clading. 02. Diesel tank suitable for 8 to 12 Hours running capacity.03. Residential Silencer.04. SMF Batteries with leads as per the Manufacturer standards
154C. AMF Control Panel:- AMF control panel shall be fabricated with 16SWG CRCA sheet shall be totally enclosed with dust and Vermin proof, floor mounted / wall mounted type and shall be comprising the following.01. Voltmeter with selector switch.02. 4 Pole MCCB incomer of ----------A rating of Schenieder / L&T make for EB and DG.03. Ammeter with selector switch with CTs.04. PF Meter and frequency Meter.05. Indicator lamps (set Run, Load ON) with fuses.06. KWH Meter of required rating.07. Set of control fuses and current transformer.08. Input Terminal board and output Terminal Board.09. Battery charger with transformer rectifier unit.10. Alternator supply air break contactor of L&T make.11. Main supply air break contactor of L&T make.12. Audio Visual announciation.13. Main supply voltage set of control relays and timers with one mode selector switch, set of push buttons.14.Control cable up to 15 Mtrs 2.5Sqmm 6 Core
15515 KVA, 3 Phase, 415, 50Hz, 19BHP, water cooled multi cylinder diesel generator set with alternator of 15 KVA out put continous rating at 0.8 p.f, Batteries .
156Supply of 185 Sqmm of 3.5core XLPE insulated, 1100V grade armoured alluminium cable with ISI mark as per specification confirming to IS:7098 (Part - I) Makes : Torrent / Unicab / Universal / Polycab / Havells / Gloster / KEI /Finolex / Payal / RR kable / Beljin /Ollvin / Finecab / RPG / V - Guard / Orbit/ Fortune Arrt / Gemscab / Bonton / SPM/ Unistar / Windsor/Avocab / Pawancab/ Nakoda / Suncab
157Earth work excavation in all soils, laying of UG cables from 70 Sqmm to 400 Sqmm on sand cussion, covering the cable with bricks and back filling the trench duly providing route indicator embedded in CC including cost and conveyance of all material and all labour charges etc, complete.
158Filling with sand including watering, ramming, consolidating and dressing complete.-Below Bed Concrete
159Providing and laying in foundations and plinth cement concrete 1 : 4 : 8 (1 cement : 4 coarse sand : 8 graded stone aggregate 40 mm nominal size) excluding the cost of centring and shuttering.-for foundation of Generator bed
160Providing and laying cement concrete 1 : 3 : 6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) excluding the cost of centring and shuttering in : a) Foundations and plinth-for Generator bed
161Reinforcement of RCC work including bending, binding and placing in position complete.b) Tar/TMT steel-at 35Kg/ 1 Cum
162Earthing with G.I. earth pipe 4.5 metre long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal/ coke and salt as required.-Earthing
163Supply, Delivery, Installation Testing of Pumps Sets at Bio Tower 2 KW-2Nos (2 Working 1 Standby)
164SUBMERSIBLE SEWAGE NON-CLOG VERTICAL PUMPSupply, delivery, installation, testing and commissioning of Submersible sewage, Non clog vertical type pump suitable for working on Air filled Dry type motor, three phase, 50 Hz +/-3%, 415V +/- 10%, AC supply, 1500 RPM synchronous speed with 3 core flat copper cable from pump to starter panel with cable end terminations (4) all supports, clamps, pipe fittings along with mechanical seal, bearing bush, strainer, arrangements for lifting for maintenance, guide pipes etc. complete set & following M.O.C: Casing CI, SS CF8M impeller, Bronze: wearing ring & Bearing bush, TC mechanical seal, CS/S.S. bearing, S.S shaft with sleeve, SS strainer & MS motor body, including compatible panel board consisting of Auto Transformer Starter suitable for local & remote pump control application consisting of Auto Transformer (vacuum impregnated, air cooled having three (3) tappings at 50%, 65% and 80%), incomer MCCB / MPCB, overload relay and contactors as per Type II coordination including digital MFM with RS 485 communication port, analogue type ammeter with selector switch, run hour meter, required protective relays & control accessories.STANDARD ACCESSORIESSupply, Delivery and Installation of Standard accessories including Power cable of PVC+Cu length 5mtrs, Pedestal auto rail coupling of Cast Iron(CI),Single Rail GR pipe of SS304 length 10Mtr and along with GRP coupler, Lifting chain with bow shackles and control panel including auto transformer starter Including Suction pipe dilavery pipe up to manifold sutuable Valves ,NRV,Pressure Gauge,Manifold etc. Total Head 11.5m
165Providing Filter Media at Bio Tower with sprinkling system, piping arrangements including valves, Bends, Tees etc complete item of work
166Construction of Wet well of 2m dia and 6.5m depth
167Earth work in excavation in foundation and trenches etc. in all kinds of soil (excluding soil containing 50% or more of shingle or small size boulders upto 30 cm size, saturated soil and rock) lift upto 1.50m and stacking the excavated soil not more than 3m clear from the edge of the excavation and returning the stacked soil in 15 cm layers, when required into plinth sides of foundation etc. consolidating each deposited layer by arming and watering of all surplus soil as directed within a lead of 50m -in all types of soils
168Earth work in excavation in foundation and trenches etc. in all kinds of soil (excluding soil containing 50% or more of shingle or small size boulders upto 30 cm size, saturated soil and rock) lift upto 1.50m and stacking the excavated soil not more than 3m clear from the edge of the excavation and returning the stacked soil in 15 cm layers, when required into plinth sides of foundation etc. consolidating each deposited layer by arming and watering of all surplus soil as directed within a lead of 50m -10% of the Total Qty-EWE from 3 to 6 metres by Mechanical means
169Earth work in excavation in foundation and trenches etc. in all kinds of soil (excluding soil containing 50% or more of shingle or small size boulders upto 30 cm size, saturated soil and rock) lift upto 1.50m and stacking the excavated soil not more than 3m clear from the edge of the excavation and returning the stacked soil in 15 cm layers, when required into plinth sides of foundation etc. consolidating each deposited layer by arming and watering of all surplus soil as directed within a lead of 50m -10% of the Total Qty-EWE from above 6 metres by Mechanical means
170Filling with sand including watering, ramming, consolidating and dressing complete.-For WET WELL (π/4x3.4^2)
171Providing and laying in foundations and plinth cement concrete 1 : 4 : 8 (1 cement : 4 coarse sand : 8 graded stone aggregate 40 mm nominal size) excluding the cost of centring and shuttering.-For WET WELL (π/4x3.4^2)
172Reinforced cement concrete in walls (any thickness) including attached pillasters,buttresses, plinth and string course, fillets etc from top of foundation up to floor two level including finishing and plastering the exposed surfaces with cement mortar 1 : 3 (1 cement : 3 fine sand) of thickness not exceeding 6 mm to give a smooth and even surface excluding cost of centring, shuttering and reinforcement in : a) M20 (1 cement : 1.5 corase sand : 3 stone aggregate 20 mm nominal size)-Base Slab
173Reinforced cement concrete in walls (any thickness) including attached pillasters,buttresses, plinth and string course, fillets etc from top of foundation up to floor two level including finishing and plastering the exposed surfaces with cement mortar 1 : 3 (1 cement : 3 fine sand) of thickness not exceeding 6 mm to give a smooth and even surface excluding cost of centring, shuttering and reinforcement in : a) M20 (1 cement : 1.5 corase sand : 3 stone aggregate 20 mm nominal size)-1st Step 0.4m Sidewalls of WET WELL (πx2.4) Below Ground
174Reinforced cement concrete in walls (any thickness) including attached pillasters,buttresses, plinth and string course, fillets etc from top of foundation up to floor two level including finishing and plastering the exposed surfaces with cement mortar 1 : 3 (1 cement : 3 fine sand) of thickness not exceeding 6 mm to give a smooth and even surface excluding cost of centring, shuttering and reinforcement in : a) M20 (1 cement : 1.5 corase sand : 3 stone aggregate 20 mm nominal size)-Sidewalls from 5.5 to 4.5m Below GL
175Reinforced cement concrete in walls (any thickness) including attached pillasters,buttresses, plinth and string course, fillets etc from top of foundation up to floor two level including finishing and plastering the exposed surfaces with cement mortar 1 : 3 (1 cement : 3 fine sand) of thickness not exceeding 6 mm to give a smooth and even surface excluding cost of centring, shuttering and reinforcement in : a) M20 (1 cement : 1.5 corase sand : 3 stone aggregate 20 mm nominal size)-2nd Step 0.3m Sidewalls of WET WELL (πx2.3) Below Ground
176Reinforced cement concrete in walls (any thickness) including attached pillasters,buttresses, plinth and string course, fillets etc from top of foundation up to floor two level including finishing and plastering the exposed surfaces with cement mortar 1 : 3 (1 cement : 3 fine sand) of thickness not exceeding 6 mm to give a smooth and even surface excluding cost of centring, shuttering and reinforcement in : a) M20 (1 cement : 1.5 corase sand : 3 stone aggregate 20 mm nominal size)-Sidewalls from 3.5 to 2.5m Below GL
177Reinforced cement concrete in walls (any thickness) including attached pillasters,buttresses, plinth and string course, fillets etc from top of foundation up to floor two level including finishing and plastering the exposed surfaces with cement mortar 1 : 3 (1 cement : 3 fine sand) of thickness not exceeding 6 mm to give a smooth and even surface excluding cost of centring, shuttering and reinforcement in : a) M20 (1 cement : 1.5 corase sand : 3 stone aggregate 20 mm nominal size)-3rd Step 0.2m Sidewalls of WET WELL (πx2.2) Below Ground
178Reinforced cement concrete in walls (any thickness) including attached pillasters,buttresses, plinth and string course, fillets etc from top of foundation up to floor two level including finishing and plastering the exposed surfaces with cement mortar 1 : 3 (1 cement : 3 fine sand) of thickness not exceeding 6 mm to give a smooth and even surface excluding cost of centring, shuttering and reinforcement in : a) M20 (1 cement : 1.5 corase sand : 3 stone aggregate 20 mm nominal size)-Floor level Beams at +1.0m
179Reinforced cement concrete in walls (any thickness) including attached pillasters,buttresses, plinth and string course, fillets etc from top of foundation up to floor two level including finishing and plastering the exposed surfaces with cement mortar 1 : 3 (1 cement : 3 fine sand) of thickness not exceeding 6 mm to give a smooth and even surface excluding cost of centring, shuttering and reinforcement in : a) M20 (1 cement : 1.5 corase sand : 3 stone aggregate 20 mm nominal size)-Floor Roof Slab 150 thick @1.0m Height ( Half of the Dia)
180Centring and shuttering including strutting, propping etc and removal of form work for a) Foundation, footings, bases of columns etc. and mass concrete-PCC Below Base Slab-For WET WELL (π/4x3.4^2)
181Extra for shuttering in circular work. -Add 20% of the rate of respective item of centring and shuttering.
1823rd Step 0.2m Sidewalls of WET WELL (πx2.2) Below Ground-1st Step 0.4m Sidewalls of WET WELL (πx2.4) Below Ground-2nd Step 0.3m Sidewalls of WET WELL (πx2.3) Below Ground-3rd Step 0.2m Sidewalls of WET WELL (πx2.2) Below Ground
183Extra for shuttering in circular work. Add 20% of the rate of respective item of centring and shuttering.
184Centring and shuttering including strutting, propping etc and removal of form work for c) Suspended floors, roofs, landings shelves and their supports, balconies and chajjas (3.5 m height).-Floor Roof Slab 150 thick @1.0m Height ( Half of the Dia)-For WET WELL (π/4x2.8^2)-For Slab Sides
185Centring and shuttering including strutting, propping etc and removal of form work for d) Lintels, beams, girders, bressumers and cantilevers etc.-Floor level Beams at +1.0m- B1 (300x450)
186Reinforcement of RCC work including bending, binding and placing in position complete.b) Tar/TMT steel
1876 mm cement plaster 1 : 3 (1 cement : 3 fine sand) finished with a floating coat of neat cement and thick coat of lime wash on top of walls when dry for bearing of RCC slabs and beams.-Internal Plastering-External Plastering above GL
188Extra for shuttering in circular work. Add 20% of the rate of respective item of centring and shuttering.
189Applying Two coats of Corroseal Epoxy Resin based Coating in one base coat and One top coats over the thoroughly prepared interior surfaces as directed by departmental officers, with each coat not exceeding 60 microns in dry film thickness and total film thickness to 240 microns including cost and conveyance of all materials to site, all labour charges ,curing and all other incidental charges etc complete for finished item of work-As per plastering Qty (Q)
190Painting two or more coats with enamel paint of approved brand and manufacture in any shade on new work to give an even shade.-External Painting above GL
191Steel work welded in built up sections/ framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required.b) In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works-for Lader
192Construction of I&D Structures
193Cutting of Trees, including Cutting of Trunks, Branches and Removal (Cutting of trees, including cutting of trunks, branches and removal of stumps, roots, stacking of serviceable material with all lifts and up to a lead of 1000 mtrs and earth filling in the depression/pit.)-Girth from 300 mm to 600 mm
194Cutting of Trees, including Cutting of Trunks, Branches and Removal (Cutting of trees, including cutting of trunks, branches and removal of stumps, roots, stacking of serviceable material with all lifts and up to a lead of 1000 mtrs and earth filling in the depression/pit.)-Girth from 600 mm to 900 mm
195Cutting of Trees, including Cutting of Trunks, Branches and Removal (Cutting of trees, including cutting of trunks, branches and removal of stumps, roots, stacking of serviceable material with all lifts and up to a lead of 1000 mtrs and earth filling in the depression/pit.)-Girth from 900 mm to 1800 mm
196Demolishing brick work in cement mortar including stacking of serviceable material and disposal of unserviceable material within 50 metres lead.-Dismantling of existing structure
197Demolishing RCC work including stacking of steel bars and disposal of un-serviceable materials within 50 metres lead.-CC Walls, beds etc,.
198Earth work in excavation in foundation and trenches etc. in all kinds of soil (excluding soil containing 50% or more of shingle or small size boulders upto 30 cm size, saturated soil and rock) lift upto 1.50m and stacking the excavated soil not more than 3m clear from the edge of the excavation and returning the stacked soil in 15 cm layers, when required into plinth sides of foundation etc. consolidating each deposited layer by arming and watering of all surplus soil as directed within a lead of 50m -in all types of soils for footings
199Earth work in excavation in foundation and trenches etc. in all kinds of soil (excluding soil containing 50% or more of shingle or small size boulders upto 30 cm size, saturated soil and rock) lift upto 1.50m and stacking the excavated soil not more than 3m clear from the edge of the excavation and returning the stacked soil in 15 cm layers, when required into plinth sides of foundation etc. consolidating each deposited layer by arming and watering of all surplus soil as directed within a lead of 50m -10% of the Total Qty
200Filling with sand including watering, ramming, consolidating and dressing complete.-Below CC bed for RCC drain
201Providing and laying in foundations and plinth cement concrete 1 : 4 : 8 (1 cement : 4 coarse sand : 8 graded stone aggregate 40 mm nominal size) excluding the cost of centring and shuttering.-CC Bed below foundation
202Reinforced concrete work in foundations, footings, bases of columns etc. and mass concrete excluding cost of centring, shuttering and reinforcement in : a) M20 (1 cement : 1.5 coarse sand : 3 stone aggregate 20 mm nominal size).-Foundation Base Slab-Weir
203Reinforced cement concrete in walls (any thickness) including attached pillasters,buttresses, plinth and string course, fillets etc from top of foundation up to floor two level including finishing and plastering the exposed surfaces with cement mortar 1 : 3 (1 cement : 3 fine sand) of thickness not exceeding 6 mm to give a smooth and even surface excluding cost of centring, shuttering and reinforcement in : a) M20 (1 cement : 1.5 corase sand : 3 stone aggregate 20 mm nominal size)-RCC Walls
204Centring and shuttering including strutting, propping etc and removal of form work for a) Foundation, footings, bases of columns etc. and mass concrete-CC Bed below foundation-Foundation Base Slab
205Centring and shuttering including strutting, propping etc and removal of form work for b) Walls (any thickness) including attached pilasters, buttresses, plinth and string courses etc.-Weir-RCC Walls
206Reinforcement of RCC work including bending, binding and placing in position complete.b) Tar/TMT steel-Reiforcement in Base-Reinforcement of RCC Walls
20725 Providing and fixing stainless steel ( Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners , stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in-charge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.).-Coarse Screen-Medium Screen
208Construction of elevated RCC Bridge with RCC NP2 Pipe and River Crossing
209Earth work in excavation in foundation and trenches etc. in all kinds of soil (excluding soil containing 50% or more of shingle or small size boulders upto 30 cm size, saturated soil and rock) lift upto 1.50m and stacking the excavated soil not more than 3m clear from the edge of the excavation and returning the stacked soil in 15 cm layers, when required into plinth sides of foundation etc. consolidating each deposited layer by arming and watering of all surplus soil as directed within a lead of 50m -in all types of soils for footings
210Earth work in excavation in foundation and trenches etc. in all kinds of soil (excluding soil containing 50% or more of shingle or small size boulders upto 30 cm size, saturated soil and rock) lift upto 1.50m and stacking the excavated soil not more than 3m clear from the edge of the excavation and returning the stacked soil in 15 cm layers, when required into plinth sides of foundation etc. consolidating each deposited layer by arming and watering of all surplus soil as directed within a lead of 50m -10% of the Total Qty
211Filling with sand including watering, ramming, consolidating and dressing complete.-Below CC bed
212Providing and laying in foundations and plinth cement concrete 1 : 4 : 8 (1 cement : 4 coarse sand : 8 graded stone aggregate 40 mm nominal size) excluding the cost of centring and shuttering.-CC Bed
213Reinforced concrete work in foundations, footings, bases of columns etc. and mass concrete excluding cost of centring, shuttering and reinforcement in : a) M20 (1 cement : 1.5 coarse sand : 3 stone aggregate 20 mm nominal size).-Footings
214Reinforced concrete work in foundations, footings, bases of columns etc. and mass concrete excluding cost of centring, shuttering and reinforcement in : a) M20 (1 cement : 1.5 coarse sand : 3 stone aggregate 20 mm nominal size).-Pedastal
215Reinforcement cement concrete work in columns, pillars, piers, abutments, post and struts etc up to floor two level including finishing and plastering the exposed surface with cement mortar 1 : 3 (1 cement : 3 fine sand) of thickness not exceeding 6 mm to give a smooth and even surface but exluding cost of centring, shuttering and reinforcement.a) M20 (1 cement : 1.5 coarse sand : 3 stone aggregate 20 mm nominal size).-Columns upto GL-Columns Above GL
216Reinforced cement concrete work in lintels, beams and bresumers up to floor two level including finishing and plastering the exposed surface with cement mortar 1 : 3 (1cement : 3 fine sand) of thickness not exceeding 6 mm to give a smooth and even surface but excluding cost of centering, shuttering and reinforcement.a) M20 (1 cement : 1.5 coarse sand : 3 stone aggregate 20 mm nominal size).-Roof Beam
217Reinforced cement concrete in suspended floors, roofs, landings and balconies upto floor two level including finishing and plastering the exposed surface with cement mortar 1 : 3 (1 cement : 3 fine sand) of thickness not exceeding 6 mm to give a smooth and even surface but excluding cost of centring and shuttering and reinforcement with M20 (1 cement : 1.5 coarse sand : 3 stone aggregate 20 mm nominal size).-Roof Slab
218Centring and shuttering including strutting, propping etc and removal of form work for a) Foundation, footings, bases of columns etc. and mass concrete-CC Bed -Footings-Pedastal
219Centring and shuttering including strutting, propping etc and removal of form work for e) Column, pillars, posts and struts etc.-Columns upto GL-Columns Above GL
220Centring and shuttering including strutting, propping etc and removal of form work for d) Lintels, beams, girders, bressumers and cantilevers etc.-Roof Beam-Roof Beam Bottom-Roof Beam Sides
221Centring and shuttering including strutting, propping etc and removal of form work forc) Suspended floors, roofs, landings shelves and their supports, balconies and chajjas (3.5 m height).-Roof Slab-Roof Bottom-Roof Sides
222Reinforcement of RCC work including bending, binding and placing in position complete.b) Tar/TMT steel
223Providing and Layng light duty non-pressure NP2 Class RCC pipes with collars jointed with stiff mixture of cement mortar in the proportion of 1:2 (1 Cement : 2 fine sand) including testing joints etc complete.-250mm dia RCC Pipe (NP2)
224Constuction of RCC Encaseing for River Crossing with RCC NP2 Pipe
225Earth work in excavation in foundation and trenches etc. in all kinds of soil (excluding soil containing 50% or more of shingle or small size boulders upto 30 cm size, saturated soil and rock) lift upto 1.50m and stacking the excavated soil not more than 3m clear from the edge of the excavation and returning the stacked soil in 15 cm layers, when required into plinth sides of foundation etc. consolidating each deposited layer by arming and watering of all surplus soil as directed within a lead of 50m
226Earth work in excavation in foundation and trenches etc. in all kinds of soil (excluding soil containing 50% or more of shingle or small size boulders upto 30 cm size, saturated soil and rock) lift upto 1.50m and stacking the excavated soil not more than 3m clear from the edge of the excavation and returning the stacked soil in 15 cm layers, when required into plinth sides of foundation etc. consolidating each deposited layer by arming and watering of all surplus soil as directed within a lead of 50m
227Filling with sand including watering, ramming, consolidating and dressing complete.
228Providing and laying in foundations and plinth cement concrete 1 : 4 : 8 (1 cement : 4 coarse sand : 8 graded stone aggregate 40 mm nominal size) excluding the cost of centring and shuttering.
229Reinforced concrete work in foundations, footings, bases of columns etc. and mass concrete excluding cost of centring, shuttering and reinforcement in : a) M20 (1 cement : 1.5 coarse sand : 3 stone aggregate 20 mm nominal size).
230Reinforced concrete work in foundations, footings, bases of columns etc. and mass concrete excluding cost of centring, shuttering and reinforcement in : a) M20 (1 cement : 1.5 coarse sand : 3 stone aggregate 20 mm nominal size).
231Centring and shuttering including strutting, propping etc and removal of form work for a) Foundation, footings, bases of columns etc. and mass concrete
232Reinforcement of RCC work including bending, binding and placing in position complete.b) Tar/TMT steel
233Providing and Layng light duty non-pressure NP2 Class RCC pipes with collars jointed with stiff mixture of cement mortar in the proportion of 1:2 (1 Cement : 2 fine sand) including testing joints etc complete.
234Constructing brick masonry manhole with 2nd class bricks in cement mortar 1 : 5 (1 cement :5 fine sand) RCC top slab with 1 : 2 : 4 mix (1 cement : 2 coarse sand : 4 stone single 20 mm nominal size), foundation concrete 1 : 4 : 8 mix (1 cement : 4 coarse sand : 8 stone aggregate 40 mm nominal size) inside plastering 12 mm thick with cement mortar 1 : 3 (1 cement : 3 coarse sand) finished with a floating coat of neat cement and making channels in cement concrete 1 : 2 : 4 mix (1 cement : 2 coarse sand : 4 stone aggregate 20 mm nominal size) neatly finished complete as per standard design.
235Supplying, laying and lowering of DI K7 Pipe for Pumping Main
236Earth work in excavation in foundation and trenches etc. in all kinds of soil (excluding soil containing 50% or more of shingle or small size boulders upto 30 cm size, saturated soil and rock) lift upto 1.50m and stacking the excavated soil not more than 3m clear from the edge of the excavation and returning the stacked soil in 15 cm layers, when required into plinth sides of foundation etc. consolidating each deposited layer by arming and watering of all surplus soil as directed within a lead of 50m
237Excavation in Ordinary Rockusing Hydraulic ExcavatorCK-90 and Tippers with disposal upto 1000 metres. (Excavation for roadway in ordinary rock with hydraulic excavator of 0.9 cum bucket capacity including cutting and loading in tippers, transporting to embankment site within all lifts and lead upto 1000 m, trimming bottom and side slopes in accordance with requirements of lines, grades and cross sections.)
238Excavation in Hard Rock (blasting prohibited) (Excavation for roadway in hard rock (blasting prohibited) with rock breakers including breaking rock,loading in tippers and disposal within all lifts and lead upto 1000 metres,trimming bottom and side slopes in accordance with requirements of lines,grades and cross sections.)Mechanised
239Earth work in excavation in foundation and trenches etc. in all kinds of soil (excluding soil containing 50% or more of shingle or small size boulders upto 30 cm size, saturated soil and rock) lift upto 1.50m and stacking the excavated soil not more than 3m clear from the edge of the excavation and returning the stacked soil in 15 cm layers, when required into plinth sides of foundation etc. consolidating each deposited layer by arming and watering of all surplus soil as directed within a lead of 50m
240Providing, laying, jointing and testing S&S Centrifugally Cast Ductile Iron double chamber Class K-7 pressure pipes conforming to IS 8329:2000 with restrained joints (bolt less), all complete.150 mm dia DI K7 pipe
241Providing and laying D.I. specials of class K-12 suitable for push-on jointing as per IS : 9523:
242Providing and fixing C.I. sluice valves (with cap) complete with bolts, nuts, rubber insertions etc. (the tail pieces if required will be paid separately) :
243Internal & External electrification yard lighting and Transformer
244Fabrication and Supply of M.S. Poles for garden posts with 'B' class 6 mtrs long 60.25mm outer dia with base plate and suitable pole cap including cost and conveyance of all material including fixing of luminaire and labour charges etc., complete. 6Mtrs 'B' Class M.S. pipe of 60.25mm dia with base plate and suitable pole cap
245Erection of steel tubular or rail pole strut in cement concrete 1:3:6 (1 cement: 3 coarse sand: 6 graded stone aggregate 40 mm nominal size) foundation including excavation and refilling and secured with holding clamps, bolts, nuts, etc. as required.
246Supplying and drawing (following size) of FRLS PVC insulated copper conductor single core cable in existing surface / I recessed steel / PVC conduit as required.
247Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, \\"C\\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioninq etc. as required.
248Laying of one number PVC insulated and PVC sheathed/XLPE power cable of 1.1 KV grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as required.
249Providing and fixing following capacity TP&N disconnector fuse switch unit inside the existing panel board with ISI marked HRC fuses including drilling holes in cubicle panel, making connections, etc. as required.100 A TP&N
250Providing and fixings 4 pole MCCB 100 amp. 16 KA in existing cubicle panel board including drilling holes in cubicle panel & making connection etc. as reqd.
251Earthing with G.I. earth pipe 4.5m long 40mm dia i/c accessories and providing masonary enclosure with cover plate having locking arrangement and watering pipe etc. (with charcoal or cokeL and salt) as read.
252Providing and laying in foundations and plinth cement concrete 1 : 4 : 8 (1 cement : 4 coarse sand : 8 graded stone aggregate 40 mm nominal size) excluding the cost of centring and shuttering.
253Supplying,installation,testing and commissioning of Astronomicaltime switch of following configuration to be mounted in feeder pillars / Lighting DBs for automatic switching On & OFF of street lights at sun set & sun rise or twilight(Auto ON, Auto OFF, Auto modes) with manual override facility with 12/24 hour display format with suitable battery and indication for relay status i/c programming at site complete as required.1 output per phase and suitable for single phase supply
254New generation energy saving andenvironmental friendly long life LED street light made up of pressure die castaluminum housing with high efficient LED as lighting source and PC cover having TOP Opening separate driver compartment with IP66 protection and impact resistance of IK07.70 W LED
255Providing of 10mmsqm 2-core & 6mmsqm 2-core PVC/XLPE Cables,Indicating Lamp,Voltmeter range 0-500 volts,Ammeter range 0-200 volts,Current transformer coil range 0-200 amp,Hinges for panel door,Panel door locksSelector switch for ammeter & voltmeter etc
256Erection of 25 KVA Transformer
257Providing and installation of Porta Cabin for Security Room
258Supplying and installation of MS Fabricated Portable Cabin With complete insulation, electrical & Plywood claddings etc, complete as per direction engineer incharge with following Technical Specifications: Portable Security Cabin ( both side finish ) Material- MS, ACP & particle Bord. Size – 6 Ft x 6 Ft Height – 7Ft Colour – White & Blue Aluminum Sliding Window -2 Nos Door – 1 Nos Electrical Switch Socket Board – 1 Nos Technical Specification1) 18 mm cement Board for floor2) 1mm MS sheet for outer3) 9mm Particle Board for interior4) 50 x 50 mm MS pipe structure 5) 40 x 20 mm MS Pipe 6) 1mm PVC carpet on floor7) Internal electrical fitting
259Providing 3.5m wide CC Road with 1m earthen shoulders on either side
260Excavation in Soil using Hydraulic Excavator CK 90 and Tippers with disposal upto 1000 metres. (Excavation for roadwork in soil with hydraulic excavator of0.9 cum bucket capacity including cutting and loading in tippers,trimming bottom and side slopes, in accordance with requirements of lines,grades and cross sections, and transporting to the embankment location within all lifts and lead upto 1000m)-EWE in ordinary soils- total Qty
261Construction of Embankment with Material Deposited from RoadwayCutting (Construction of embankment with approved materials deposited at site from roadway cutting and excavation from drain and foundation of other structures graded and compacted to meet requirement of table 300-2)-for formation of road 90% total Qty
262Embankment Construction with Material Obtained from Borrow Pits(Construction of embankment with approved material obtained from borrow pits with all lifts and leads, transporting to site, spreading, grading to required slope and compacting to meet requirement of table 300-2)-for formation of road
263Granular Sub-Base with Coarse Graded Material ( Table:- 400- 2)(Construction of granular sub-base by providing coarse graded material, spreading in uniform layers with motor grader on prepared surface, mixing by mix in place method with rotavator at OMC, and compacting with vibratory roller to achieve the desired density, complete as per clause 401) for grading- I Material-for the formation of new road
264Dry Lean Cement Concrete Sub- base (Construction of dry lean cement concrete Sub- base over a prepared sub-grade with coarse and fine aggregate conforming to IS: 383, the size of coarse aggregate not exceeding 25 mm, aggregate cement ratio not to exceed 15:1, aggregate gradation after blending to be as per table 600-1, cement content not to be less than 150 kg/ cum, optimum moisture content to be determined during trial length construction, concrete strength not to be less than 10 Mpa at 7 days, mixed in a batching plant, transported to site, laid with a paver with electronic sensor, compacting with 8-10 tonnes vibratory roller, finishing and curing.)
265Cement Concrete Pavement (Construction of un-reinforced, dowel jointed,plain cement concrete pavement over a prepared sub base with 43 grade cement @ 400 kg per cum, coarse and fine aggregate conforming to IS 383,maximum size of coarse aggregate not exceeding 25 mm, mixed in a batching and mixing plant as per approved mix design, for M40 Grade having minimum 28 days flexural strength of 4.5 Mpa, using approved admixtures, transported to site, laid with a fixed form or slip form paver,spread, compacted and finished in a continuous operation including provision of contraction, expansion, construction and longitudinal joints, joint filler, separation membrane, sealant primer, joint sealant, debonding strip,dowel bar, tie rod, admixtures as approved, curing compound, finishing to lines and grades as per drawing. )
266Construction of Subgrade and Earthen Shoulders (Construction ofsubgrade and earthen shoulders with approved material obtained from borrow pits with all lifts & leads, transporting to site, spreading, grading to required slope and compacted to meet requirement of table No. 300-2)
267Construction of Compound wall with Chain Link Fencing and MS Gate
268Earth work in excavation in foundation and trenches etc. in all kinds of soil (excluding soil containing 50% or more of shingle or small size boulders upto 30 cm size, saturated soil and rock) lift upto 1.50m and stacking the excavated soil not more than 3m clear from the edge of the excavation and returning the stacked soil in 15 cm layers, when required into plinth sides of foundation etc. consolidating each deposited layer by arming and watering of all surplus soil as directed within a lead of 50m in all types of soils for footings
269Earth work in excavation in foundation and trenches etc. in all kinds of soil (excluding soil containing 50% or more of shingle or small size boulders upto 30 cm size, saturated soil and rock) lift upto 1.50m and stacking the excavated soil not more than 3m clear from the edge of the excavation and returning the stacked soil in 15 cm layers, when required into plinth sides of foundation etc. consolidating each deposited layer by arming and watering of all surplus soil as directed within a lead of 50m 10% of the Total Qty
270Filling with sand including watering, ramming, consolidating and dressing complete.Below CC bed
271Providing and laying in foundations and plinth cement concrete 1 : 4 : 8 (1 cement : 4 coarse sand : 8 graded stone aggregate 40 mm nominal size) excluding the cost of centring and shuttering.CC Bed
272Reinforced concrete work in foundations, footings, bases of columns etc. and mass concrete excluding cost of centring, shuttering and reinforcement in : a) M20 (1 cement : 1.5 coarse sand : 3 stone aggregate 20 mm nominal size).Footings
273Reinforced concrete work in foundations, footings, bases of columns etc. and mass concrete excluding cost of centring, shuttering and reinforcement in : a) M20 (1 cement : 1.5 coarse sand : 3 stone aggregate 20 mm nominal size).Pedastal
274Reinforcement cement concrete work in columns, pillars, piers, abutments, post and struts etc up to floor two level including finishing and plastering the exposed surface with cement mortar 1 : 3 (1 cement : 3 fine sand) of thickness not exceeding 6 mm to give a smooth and even surface but exluding cost of centring, shuttering and reinforcement.a) M20 (1 cement : 1.5 coarse sand : 3 stone aggregate 20 mm nominal size).Columns upto GLColumns Above GL
275Centring and shuttering including strutting, propping etc and removal of form work for a) Foundation, footings, bases of columns etc. and mass concreteCC Bed FootingsPedastal
276Centring and shuttering including strutting, propping etc and removal of form work for e) Column, pillars, posts and struts etc.Columns upto GLColumns Above GL
277Reinforcement of RCC work including bending, binding and placing in position complete.b) Tar/TMT steelFootingsPedastalColumns upto GLColumns Above GL
278Steel work welded in built up sections/ framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required.b) In gratings, frames, guard bar, ladder, railings, brackets, gates and similar worksfor MS Gate
279Earth work in excavation in foundation and trenches in soils containing 50% or more of shingle or small size boulders upto 30 cm size, lift upto 1.50 m and stacking the excavated soil not more than 3 m clear from the edge of the excavation and returning the stacked soil in 15 cm layers when required, into plinth, sides of foundation etc consolidating each deposited layer by ramming and watering and then disposing of all surplus excavated soil as directed within a lead of 50m.for foundations of MS fencing posts - Mainfor foundations of MS fencing posts - Inclined support at every 30m
280Providing and laying in foundations and plinth cement concrete 1 : 5 : 10 (1 cement : 5 coarse sand : 10 graded stone aggregate 40 mm nominal size) excluding the cost of centring and shuttering.for foundations of MS fencing posts - Mainfor foundations of MS fencing posts - Inclined support at every 30m
281Reinforced concrete work in foundations, footings, bases of columns etc. and mass concrete excluding cost of centring, shuttering and reinforcement in : a) M20 (1 cement : 1.5 coarse sand : 3 stone aggregate 20 mm nominal size).for foundations of MS fencing posts - Mainfor foundations of MS fencing posts - Inclined support at every 30m
2821.20 m high welded steel wire fencing with 1.80 m RCC posts of standard design placed at every 3 m apart embedded in cement concrete blocks 45 x 45 x 60 cm of mix 1 : 5 : 10 (1 cement : 5 fine sand : 10 stone aggt. 40 mm nominal size), corner end and every 10th post to be strutted and embedded in cement concrete blocks of 70 x 45 x 50 cm of same mix provided with welded steel wire fabric 0.90 m wide, rectangular mesh 75 x 25 mm size weighing not less than 7.75 kg per Sq.m. fixed between the two posts fitted and fixed with GI staples on wooden plugs or tied to 6 mm bar nibs with binding wire including earth work in excavation, concrete work and cost of posts, struts etc complete.Area as per the Drawing - Longitudinal length x Height
283Add Carriage Charges
284Supply, Delivery, Installation Testing of Pumps Sets at Wet well 7KW-2Nos (1 Working 1 Standby)
285SUBMERSIBLE SEWAGE NON-CLOG VERTICAL PUMPSupply, delivery, installation, testing and commissioning of Submersible sewage, Non clog vertical type pump suitable for working on Air filled Dry type motor, three phase, 50 Hz +/-3%, 415V +/- 10%, AC supply, 1500 RPM synchronous speed with 3 core flat copper cable from pump to starter panel with cable end terminations (4) all supports, clamps, pipe fittings along with mechanical seal, bearing bush, strainer, arrangements for lifting for maintenance, guide pipes etc. complete set & following M.O.C: Casing CI, SS CF8M impeller, Bronze: wearing ring & Bearing bush, TC mechanical seal, CS/S.S. bearing, S.S shaft with sleeve, SS strainer & MS motor body, including compatible panel board consisting of Auto Transformer Starter suitable for local & remote pump control application consisting of Auto Transformer (vacuum impregnated, air cooled having three (3) tappings at 50%, 65% and 80%), incomer MCCB / MPCB, overload relay and contactors as per Type II coordination including digital MFM with RS 485 communication port, analogue type ammeter with selector switch, run hour meter, required protective relays & control accessories.STANDARD ACCESSORIESSupply, Delivery and Installation of Standard accessories including Power cable of PVC+Cu length 5mtrs, Pedestal auto rail coupling of Cast Iron(CI),Single Rail GR pipe of SS304 length 10Mtr and along with GRP coupler, Lifting chain with bow shackles and control panel including auto transformer starter Including Suction pipe dilavery pipe up to manifold sutuable Valves ,NRV,Pressure Gauge,Manifold etc. Total Head 17m
286Construction of Proposed STP of 0.75MLD with Bio Tower - STP2
287Jungle Clearing Land Fill & Site Levelling
288Jngle Clearing and Grubbing Road Land (Clearing and grubbing road land including uprooting rank vegetation, grass, bushes, shrubs, saplings and trees girth up to 300mm, removal of stumps of trees cut earlier and disposal of unserviceable materials and stacking of serviceable material to be used or auctioned up to a lead of 1000 metres including removal and disposal of top organic soil not exceeding 150 mm in thickness
289Earth work in excavation in foundation and trenches etc. in all kinds of soil (excluding soil containing 50% or more of shingle or small size boulders upto 30 cm size, saturated soil and rock) lift upto 1.50m and stacking the excavated soil not more than 3m clear from the edge of the excavation and returning the stacked soil in 15 cm layers, when required into plinth sides of foundation etc. consolidating each deposited layer by arming and watering of all surplus soil as directed within a lead of 50m
290Embankment Construction with Material Obtained from Borrow Pits(Construction of embankment with approved material obtained from borrow pits with all lifts and leads, transporting to site, spreading, grading to required slope and compacting to meet requirement of table 300-2)
291Providing and laying Pitching on slopes laid over prepared filter media including boulder apron laid dry in front of toe of embankment complete as per drawing and Technical specifications a) Stone / Boulders
292Construction of RCC elevated Platform for screen channel and Grit Chamber
293Earth work in excavation in foundation and trenches etc. in all kinds of soil (excluding soil containing 50% or more of shingle or small size boulders upto 30 cm size, saturated soil and rock) lift upto 1.50m and stacking the excavated soil not more than 3m clear from the edge of the excavation and returning the stacked soil in 15 cm layers, when required into plinth sides of foundation etc. consolidating each deposited layer by arming and watering of all surplus soil as directed within a lead of 50m in all types of soils for footings
294Earth work in excavation in foundation and trenches etc. in all kinds of soil (excluding soil containing 50% or more of shingle or small size boulders upto 30 cm size, saturated soil and rock) lift upto 1.50m and stacking the excavated soil not more than 3m clear from the edge of the excavation and returning the stacked soil in 15 cm layers, when required into plinth sides of foundation etc. consolidating each deposited layer by arming and watering of all surplus soil as directed within a lead of 50m 10% of the Total Qty
295Filling with sand including watering, ramming, consolidating and dressing complete.Below CC bed Below CC bed
296Providing and laying in foundations and plinth cement concrete 1 : 4 : 8 (1 cement : 4 coarse sand : 8 graded stone aggregate 40 mm nominal size) excluding the cost of centring and shuttering.CC Bed
297Reinforced concrete work in foundations, footings, bases of columns etc. and mass concrete excluding cost of centring, shuttering and reinforcement in : a) M20 (1 cement : 1.5 coarse sand : 3 stone aggregate 20 mm nominal size).Footings
298Reinforced concrete work in foundations, footings, bases of columns etc. and mass concrete excluding cost of centring, shuttering and reinforcement in : a) M20 (1 cement : 1.5 coarse sand : 3 stone aggregate 20 mm nominal size).Pedastal
299Reinforcement cement concrete work in columns, pillars, piers, abutments, post and struts etc up to floor two level including finishing and plastering the exposed surface with cement mortar 1 : 3 (1 cement : 3 fine sand) of thickness not exceeding 6 mm to give a smooth and even surface but exluding cost of centring, shuttering and reinforcement.a) M20 (1 cement : 1.5 coarse sand : 3 stone aggregate 20 mm nominal size).Columns upto GLColumns Above GL
300Reinforced cement concrete work in lintels, beams and bresumers up to floor two level including finishing and plastering the exposed surface with cement mortar 1 : 3 (1cement : 3 fine sand) of thickness not exceeding 6 mm to give a smooth and even surface but excluding cost of centering, shuttering and reinforcement.a) M20 (1 cement : 1.5 coarse sand : 3 stone aggregate 20 mm nominal size).Plinth BeamBracing Tie Beam @ 4m heightRoof Beam
301Reinforced cement concrete in suspended floors, roofs, landings and balconies upto floor two level including finishing and plastering the exposed surface with cement mortar 1 : 3 (1 cement : 3 fine sand) of thickness not exceeding 6 mm to give a smooth and even surface but excluding cost of centring and shuttering and reinforcement with M20 (1 cement : 1.5 coarse sand : 3 stone aggregate 20 mm nominal size).Roof Slab
302Centring and shuttering including strutting, propping etc and removal of form work for a) Foundation, footings, bases of columns etc. and mass concreteCC Bed FootingsPedastal
303Centring and shuttering including strutting, propping etc and removal of form work for e) Column, pillars, posts and struts etc.Columns upto GLColumns Above GL
304Centring and shuttering including strutting, propping etc and removal of form work for d) Lintels, beams, girders, bressumers and cantilevers etc.Roof BeamRoof Beam BottomRoof Beam Sides
305Centring and shuttering including strutting, propping etc and removal of form work forc) Suspended floors, roofs, landings shelves and their supports, balconies and chajjas (3.5 m height).Roof SlabRoof BottomRoof Sides
306Reinforcement of RCC work including bending, binding and placing in position complete.b) Tar/TMT steelFootingsPedastalColumns upto GLColumns Above GLPlinth BeamBracing Tie Beam @ 4m heightRoof BeamRoof Slab
307Steel work welded in built up sections/ framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required.b) In gratings, frames, guard bar, ladder, railings, brackets, gates and similar worksfor Lader
308Construction of RCC channel for Grid Chamber Fine Screen & Medium Screen
309Reinforced cement concrete in walls (any thickness) including attached pillasters,buttresses, plinth and string course, fillets etc from top of foundation up to floor two level including finishing and plastering the exposed surfaces with cement mortar 1 : 3 (1 cement : 3 fine sand) of thickness not exceeding 6 mm to give a smooth and even surface excluding cost of centring, shuttering and reinforcement in : a) M20 (1 cement : 1.5 corase sand : 3 stone aggregate 20 mm nominal size)RCC Walls
310Centring and shuttering including strutting, propping etc and removal of form work for b) Walls (any thickness) including attached pilasters, buttresses, plinth and string courses etc.RCC Walls
311Reinforcement of RCC work including bending, binding and placing in position complete.b) Tar/TMT steelReiforcement in BaseReinforcement of RCC Walls
31225 Providing and fixing stainless steel ( Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners , stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in-charge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.).Coarse ScreenWeight of SS Coarse Screen in - Kg/SqmMedium Screen Weight of SS Medium Screen in - Kg/SqmTotal Weight of Coarse & Medium Screen
313Construction of RCC Grit Chamber
314Reinforced cement concrete in walls (any thickness) including attached pillasters,buttresses, plinth and string course, fillets etc from top of foundation up to floor two level including finishing and plastering the exposed surfaces with cement mortar 1 : 3 (1 cement : 3 fine sand) of thickness not exceeding 6 mm to give a smooth and even surface excluding cost of centring, shuttering and reinforcement in : a) M20 (1 cement : 1.5 corase sand : 3 stone aggregate 20 mm nominal size)RCC Walls
315Centring and shuttering including strutting, propping etc and removal of form work for b) Walls (any thickness) including attached pilasters, buttresses, plinth and string courses etc.RCC Walls
316Reinforcement of RCC work including bending, binding and placing in position complete.b) Tar/TMT steelReiforcement in BaseReinforcement of RCC Walls
317Construction of RCC Primary Settling Tank
318Earth work in excavation in foundation and trenches etc. in all kinds of soil (excluding soil containing 50% or more of shingle or small size boulders upto 30 cm size, saturated soil and rock) lift upto 1.50m and stacking the excavated soil not more than 3m clear from the edge of the excavation and returning the stacked soil in 15 cm layers, when required into plinth sides of foundation etc. consolidating each deposited layer by arming and watering of all surplus soil as directed within a lead of 50m % of the above Quantity.
319Earth work in excavation in foundation and trenches etc. in all kinds of soil (excluding soil containing 50% or more of shingle or small size boulders upto 30 cm size, saturated soil and rock) lift upto 1.50m and stacking the excavated soil not more than 3m clear from the edge of the excavation and returning the stacked soil in 15 cm layers, when required into plinth sides of foundation etc. consolidating each deposited layer by arming and watering of all surplus soil as directed within a lead of 50m % of the above Quantity.
320Filling with sand including watering, ramming, consolidating and dressing complete.Sand Bed below CC bedFor FootingsFor walls
321Providing and laying in foundations and plinth cement concrete 1 : 4 : 8 (1 cement : 4 coarse sand : 8 graded stone aggregate 40 mm nominal size) excluding the cost of centring and shuttering.CC BedFor FootingsFor walls
322Reinforced concrete work in foundations, footings, bases of columns etc. and mass concrete excluding cost of centring, shuttering and reinforcement in : a) M20 (1 cement : 1.5 coarse sand : 3 stone aggregate 20 mm nominal size).FootingsPedestal For Base slab
323Reinforcement cement concrete work in columns, pillars, piers, abutments, post and struts etc up to floor two level including finishing and plastering the exposed surface with cement mortar 1 : 3 (1 cement : 3 fine sand) of thickness not exceeding 6 mm to give a smooth and even surface but exluding cost of centring, shuttering and reinforcement.a) M20 (1 cement : 1.5 coarse sand : 3 stone aggregate 20 mm nominal size).Columns upto GLColumns Above GL
324Reinforced cement concrete in walls (any thickness) including attached pillasters,buttresses, plinth and string course, fillets etc from top of foundation up to floor two level including finishing and plastering the exposed surfaces with cement mortar 1 : 3 (1 cement : 3 fine sand) of thickness not exceeding 6 mm to give a smooth and even surface excluding cost of centring, shuttering and reinforcement in : a) M20 (1 cement : 1.5 corase sand : 3 stone aggregate 20 mm nominal size)For RCC walls Circuferance length
325Reinforced cement concrete work in lintels, beams and bresumers up to floor two level including finishing and plastering the exposed surface with cement mortar 1 : 3 (1cement : 3 fine sand) of thickness not exceeding 6 mm to give a smooth and even surface but excluding cost of centering, shuttering and reinforcement.a) M20 (1 cement : 1.5 coarse sand : 3 stone aggregate 20 mm nominal size).Plinth BeamRoof Beam
326Reinforced cement concrete in suspended floors, roofs, landings and balconies upto floor two level including finishing and plastering the exposed surface with cement mortar 1 : 3 (1 cement : 3 fine sand) of thickness not exceeding 6 mm to give a smooth and even surface but excluding cost of centring and shuttering and reinforcement with M20 (1 cement : 1.5 coarse sand : 3 stone aggregate 20 mm nominal size). For inspection track along the wall
327Centring and shuttering including strutting, propping etc and removal of form work for a) Foundation, footings, bases of columns etc. and mass concreteCC BedFootingsPedestal
328Centring and shuttering including strutting, propping etc and removal of form work for d) Lintels, beams, girders, bressumers and cantilevers etc.Plinth Beam BottomPlinth Beam Sides
329Centring and shuttering including strutting, propping etc and removal of form work forc) Suspended floors, roofs, landings shelves and their supports, balconies and chajjas (3.5 m height). For inspection track along the wallRoof BottomRoof Sides
330Centring and shuttering including strutting, propping etc and removal of form work for b) Walls (any thickness) including attached pilasters, buttresses, plinth and string courses etc.For Base slab For RCC walls
331Extra for shuttering in circular work. Add 20% of the rate of respective item of centring and shuttering.
3326 mm cement plaster 1 : 3 (1 cement : 3 fine sand) finished with a floating coat of neat cement and thick coat of lime wash on top of walls when dry for bearing of RCC slabs and beams.inner side of the structure
333Applying Two coats of Corroseal Epoxy Resin based Coating in one base coat and One top coats over the thoroughly prepared interior surfaces as directed by departmental officers, with each coat not exceeding 60 microns in dry film thickness and total film thickness to 240 microns including cost and conveyance of all materials to site, all labour charges ,curing and all other incidental charges etc complete for finished item of workAs per plastering Qty (Q)
334Providing and fixing of FRP Hand railings with Vertical Post of size 50 x 50x 5 mm speacing of at every 1000mm c/c with 1000mm height,and Middle Tube 25mm x 30mm, Top rail of 65 x 45 mm. Resin Polymer +UV Grade with Hardware : SS304 (As Per design), Yellow color or other as per approved. Including cost of all materials,fittings, machinery, labour, etc., finsished item of work as per direction of engineer incharge.on both sides of the inspection Walkway slab
335Reinforcement of RCC work including bending, binding and placing in position complete.b) Tar/TMT steelBase slabWallsSlab
336Construction of RCC Bio Tower
337Earth work in excavation in foundation and trenches etc. in all kinds of soil (excluding soil containing 50% or more of shingle or small size boulders upto 30 cm size, saturated soil and rock) lift upto 1.50m and stacking the excavated soil not more than 3m clear from the edge of the excavation and returning the stacked soil in 15 cm layers, when required into plinth sides of foundation etc. consolidating each deposited layer by arming and watering of all surplus soil as directed within a lead of 50m % of the above Quantity.
338Earth work in excavation in foundation and trenches etc. in all kinds of soil (excluding soil containing 50% or more of shingle or small size boulders upto 30 cm size, saturated soil and rock) lift upto 1.50m and stacking the excavated soil not more than 3m clear from the edge of the excavation and returning the stacked soil in 15 cm layers, when required into plinth sides of foundation etc. consolidating each deposited layer by arming and watering of all surplus soil as directed within a lead of 50m % of the above Quantity.
339Filling with sand including watering, ramming, consolidating and dressing complete.Sand Bed below CC bedFor FootingsFor walls
340Providing and laying in foundations and plinth cement concrete 1 : 4 : 8 (1 cement : 4 coarse sand : 8 graded stone aggregate 40 mm nominal size) excluding the cost of centring and shuttering.CC BedFor FootingsFor walls
341Reinforced concrete work in foundations, footings, bases of columns etc. and mass concrete excluding cost of centring, shuttering and reinforcement in : a) M20 (1 cement : 1.5 coarse sand : 3 stone aggregate 20 mm nominal size).FootingsPedestal For Base slab
342Reinforcement cement concrete work in columns, pillars, piers, abutments, post and struts etc up to floor two level including finishing and plastering the exposed surface with cement mortar 1 : 3 (1 cement : 3 fine sand) of thickness not exceeding 6 mm to give a smooth and even surface but exluding cost of centring, shuttering and reinforcement.a) M20 (1 cement : 1.5 coarse sand : 3 stone aggregate 20 mm nominal size).Columns upto GLColumns Above GL
343Reinforced cement concrete in walls (any thickness) including attached pillasters,buttresses, plinth and string course, fillets etc from top of foundation up to floor two level including finishing and plastering the exposed surfaces with cement mortar 1 : 3 (1 cement : 3 fine sand) of thickness not exceeding 6 mm to give a smooth and even surface excluding cost of centring, shuttering and reinforcement in : a) M20 (1 cement : 1.5 corase sand : 3 stone aggregate 20 mm nominal size)For RCC walls side length
344Reinforced cement concrete work in lintels, beams and bresumers up to floor two level including finishing and plastering the exposed surface with cement mortar 1 : 3 (1cement : 3 fine sand) of thickness not exceeding 6 mm to give a smooth and even surface but excluding cost of centering, shuttering and reinforcement.a) M20 (1 cement : 1.5 coarse sand : 3 stone aggregate 20 mm nominal size).Grid Tie Beam Spacing @ 0.9m C/C at 1.2m heightRoof Beam
345Reinforced cement concrete in suspended floors, roofs, landings and balconies upto floor two level including finishing and plastering the exposed surface with cement mortar 1 : 3 (1 cement : 3 fine sand) of thickness not exceeding 6 mm to give a smooth and even surface but excluding cost of centring and shuttering and reinforcement with M20 (1 cement : 1.5 coarse sand : 3 stone aggregate 20 mm nominal size). For inspection track along the Roof beam
346Centring and shuttering including strutting, propping etc and removal of form work for a) Foundation, footings, bases of columns etc. and mass concreteCC BedFootingsPedestal
347Centring and shuttering including strutting, propping etc and removal of form work for d) Lintels, beams, girders, bressumers and cantilevers etc.Grid Tie Beam Spacing @ 0.9m C/C at 1.2m heightRoof Beam BottomRoof Beam Sides
348Centring and shuttering including strutting, propping etc and removal of form work forc) Suspended floors, roofs, landings shelves and their supports, balconies and chajjas (3.5 m height). For inspection track along the Roof beamRoof BottomRoof Sides
349Centring and shuttering including strutting, propping etc and removal of form work for b) Walls (any thickness) including attached pilasters, buttresses, plinth and string courses etc.For Base slab For RCC walls
350Extra for shuttering in circular work. Add 20% of the rate of respective item of centring and shuttering.
3516 mm cement plaster 1 : 3 (1 cement : 3 fine sand) finished with a floating coat of neat cement and thick coat of lime wash on top of walls when dry for bearing of RCC slabs and beams.inner side of the structure
352Applying Two coats of Corroseal Epoxy Resin based Coating in one base coat and One top coats over the thoroughly prepared interior surfaces as directed by departmental officers, with each coat not exceeding 60 microns in dry film thickness and total film thickness to 240 microns including cost and conveyance of all materials to site, all labour charges ,curing and all other incidental charges etc complete for finished item of workAs per plastering Qty (Q)
353Providing and fixing of FRP Hand railings with Vertical Post of size 50 x 50x 5 mm speacing of at every 1000mm c/c with 1000mm height,and Middle Tube 25mm x 30mm, Top rail of 65 x 45 mm. Resin Polymer +UV Grade with Hardware : SS304 (As Per design), Yellow color or other as per approved. Including cost of all materials,fittings, machinery, labour, etc., finsished item of work as per direction of engineer incharge.on both sides of the inspection Walkway slab
354Reinforcement of RCC work including bending, binding and placing in position complete.b) Tar/TMT steelBase slabWallsSlab
355Construction of RCC Secondary Settling Tank
356Earth work in excavation in foundation and trenches etc. in all kinds of soil (excluding soil containing 50% or more of shingle or small size boulders upto 30 cm size, saturated soil and rock) lift upto 1.50m and stacking the excavated soil not more than 3m clear from the edge of the excavation and returning the stacked soil in 15 cm layers, when required into plinth sides of foundation etc. consolidating each deposited layer by arming and watering of all surplus soil as directed within a lead of 50m -% of the above Quantity.
357Earth work in excavation in foundation and trenches etc. in all kinds of soil (excluding soil containing 50% or more of shingle or small size boulders upto 30 cm size, saturated soil and rock) lift upto 1.50m and stacking the excavated soil not more than 3m clear from the edge of the excavation and returning the stacked soil in 15 cm layers, when required into plinth sides of foundation etc. consolidating each deposited layer by arming and watering of all surplus soil as directed within a lead of 50m -% of the above Quantity.
358Filling with sand including watering, ramming, consolidating and dressing complete.-Filling with sand including watering, ramming, consolidating and dressing complete.-Sand Bed below CC bed-For Footings-For walls
359Providing and laying in foundations and plinth cement concrete 1 : 4 : 8 (1 cement : 4 coarse sand : 8 graded stone aggregate 40 mm nominal size) excluding the cost of centring and shuttering.-CC Bed-For Footings-For walls
360Reinforced concrete work in foundations, footings, bases of columns etc. and mass concrete excluding cost of centring, shuttering and reinforcement in : a) M20 (1 cement : 1.5 coarse sand : 3 stone aggregate 20 mm nominal size).-Footings-Pedestal -For Base slab
361Reinforcement cement concrete work in columns, pillars, piers, abutments, post and struts etc up to floor two level including finishing and plastering the exposed surface with cement mortar 1 : 3 (1 cement : 3 fine sand) of thickness not exceeding 6 mm to give a smooth and even surface but exluding cost of centring, shuttering and reinforcement.a) M20 (1 cement : 1.5 coarse sand : 3 stone aggregate 20 mm nominal size).-Columns upto GL-Columns Above GL
362Reinforced cement concrete in walls (any thickness) including attached pillasters,buttresses, plinth and string course, fillets etc from top of foundation up to floor two level including finishing and plastering the exposed surfaces with cement mortar 1 : 3 (1 cement : 3 fine sand) of thickness not exceeding 6 mm to give a smooth and even surface excluding cost of centring, shuttering and reinforcement in : a) M20 (1 cement : 1.5 corase sand : 3 stone aggregate 20 mm nominal size)-For RCC walls -Circuferance length
363Reinforced cement concrete work in lintels, beams and bresumers up to floor two level including finishing and plastering the exposed surface with cement mortar 1 : 3 (1cement : 3 fine sand) of thickness not exceeding 6 mm to give a smooth and even surface but excluding cost of centering, shuttering and reinforcement.a) M20 (1 cement : 1.5 coarse sand : 3 stone aggregate 20 mm nominal size).-Plinth Beam-Roof Beam
364Reinforced cement concrete in suspended floors, roofs, landings and balconies upto floor two level including finishing and plastering the exposed surface with cement mortar 1 : 3 (1 cement : 3 fine sand) of thickness not exceeding 6 mm to give a smooth and even surface but excluding cost of centring and shuttering and reinforcement with M20 (1 cement : 1.5 coarse sand : 3 stone aggregate 20 mm nominal size).- For inspection track along the wall
365Centring and shuttering including strutting, propping etc and removal of form work for a) Foundation, footings, bases of columns etc. and mass concrete-CC Bed-Footings-Pedestal
366Centring and shuttering including strutting, propping etc and removal of form work for d) Lintels, beams, girders, bressumers and cantilevers etc.-Plinth Beam Bottom-Plinth Beam Sides
367Centring and shuttering including strutting, propping etc and removal of form work forc) Suspended floors, roofs, landings shelves and their supports, balconies and chajjas (3.5 m height).- For inspection track along the wall-Roof Bottom-Roof Sides
368Centring and shuttering including strutting, propping etc and removal of form work for b) Walls (any thickness) including attached pilasters, buttresses, plinth and string courses etc.-For Base slab -For RCC walls
369Extra for shuttering in circular work. Add 20% of the rate of respective item of centring and shuttering.
3706 mm cement plaster 1 : 3 (1 cement : 3 fine sand) finished with a floating coat of neat cement and thick coat of lime wash on top of walls when dry for bearing of RCC slabs and beams.-inner side of the structure
371Applying Two coats of Corroseal Epoxy Resin based Coating in one base coat and One top coats over the thoroughly prepared interior surfaces as directed by departmental officers, with each coat not exceeding 60 microns in dry film thickness and total film thickness to 240 microns including cost and conveyance of all materials to site, all labour charges ,curing and all other incidental charges etc complete for finished item of work-As per plastering Qty (Q)
372Providing and fixing of FRP Hand railings with Vertical Post of size 50 x 50x 5 mm speacing of at every 1000mm c/c with 1000mm height,and Middle Tube 25mm x 30mm, Top rail of 65 x 45 mm. Resin Polymer +UV Grade with Hardware : SS304 (As Per design), Yellow color or other as per approved. Including cost of all materials,fittings, machinery, labour, etc., finsished item of work as per direction of engineer incharge.-on both sides of the inspection Walkway slab
373Reinforcement of RCC work including bending, binding and placing in position complete.b) Tar/TMT steel-Base slab-Walls-Slab
374Construction of RCC channel for Fecal sludge collection Chamber Fine Screen & Medium Screen
375Earth work in excavation in foundation and trenches etc. in all kinds of soil (excluding soil containing 50% or more of shingle or small size boulders upto 30 cm size, saturated soil and rock) lift upto 1.50m and stacking the excavated soil not more than 3m clear from the edge of the excavation and returning the stacked soil in 15 cm layers, when required into plinth sides of foundation etc. consolidating each deposited layer by arming and watering of all surplus soil as directed within a lead of 50m -in all types of soils
376Earth work in excavation in foundation and trenches etc. in all kinds of soil (excluding soil containing 50% or more of shingle or small size boulders upto 30 cm size, saturated soil and rock) lift upto 1.50m and stacking the excavated soil not more than 3m clear from the edge of the excavation and returning the stacked soil in 15 cm layers, when required into plinth sides of foundation etc. consolidating each deposited layer by arming and watering of all surplus soil as directed within a lead of 50m -10% of the Total Qty
377Filling with sand including watering, ramming, consolidating and dressing complete.-Below CC bed for RCC drain
378Providing and laying in foundations and plinth cement concrete 1 : 4 : 8 (1 cement : 4 coarse sand : 8 graded stone aggregate 40 mm nominal size) excluding the cost of centring and shuttering.-CC Bed for RCC Drain
379Reinforced concrete work in foundations, footings, bases of columns etc. and mass concrete excluding cost of centring, shuttering and reinforcement in : a) M20 (1 cement : 1.5 coarse sand : 3 stone aggregate 20 mm nominal size).-Foundation Base Slab
380Reinforced cement concrete in walls (any thickness) including attached pillasters,buttresses, plinth and string course, fillets etc from top of foundation up to floor two level including finishing and plastering the exposed surfaces with cement mortar 1 : 3 (1 cement : 3 fine sand) of thickness not exceeding 6 mm to give a smooth and even surface excluding cost of centring, shuttering and reinforcement in : a) M20 (1 cement : 1.5 corase sand : 3 stone aggregate 20 mm nominal size)-RCC Walls
381Centring and shuttering including strutting, propping etc and removal of form work for a) Foundation, footings, bases of columns etc. and mass concrete-CC Bed for RCC Drain-Foundation Base Slab
382Centring and shuttering including strutting, propping etc and removal of form work for b) Walls (any thickness) including attached pilasters, buttresses, plinth and string courses etc.-RCC Walls
383Reinforcement of RCC work including bending, binding and placing in position complete.b) Tar/TMT steel-Reiforcement in Base-Reinforcement of RCC Walls
38425 Providing and fixing stainless steel ( Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners , stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in-charge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.).-Coarse Screen-Medium Screen
385Construction of RCC Fecal Sludge collection Chamber
386Earth work in excavation in foundation and trenches etc. in all kinds of soil (excluding soil containing 50% or more of shingle or small size boulders upto 30 cm size, saturated soil and rock) lift upto 1.50m and stacking the excavated soil not more than 3m clear from the edge of the excavation and returning the stacked soil in 15 cm layers, when required into plinth sides of foundation etc. consolidating each deposited layer by arming and watering of all surplus soil as directed within a lead of 50m -in all types of soils
387Earth work in excavation in foundation and trenches etc. in all kinds of soil (excluding soil containing 50% or more of shingle or small size boulders upto 30 cm size, saturated soil and rock) lift upto 1.50m and stacking the excavated soil not more than 3m clear from the edge of the excavation and returning the stacked soil in 15 cm layers, when required into plinth sides of foundation etc. consolidating each deposited layer by arming and watering of all surplus soil as directed within a lead of 50m -10% of the Total Qty
388Filling with sand including watering, ramming, consolidating and dressing complete.-Below CC bed for RCC Grit Chamber
389Providing and laying in foundations and plinth cement concrete 1 : 4 : 8 (1 cement : 4 coarse sand : 8 graded stone aggregate 40 mm nominal size) excluding the cost of centring and shuttering.-CC Bed for RCC Grit Chamber
390Reinforced concrete work in foundations, footings, bases of columns etc. and mass concrete excluding cost of centring, shuttering and reinforcement in : a) M20 (1 cement : 1.5 coarse sand : 3 stone aggregate 20 mm nominal size).-Foundation Base Slab
391Reinforced cement concrete in walls (any thickness) including attached pillasters,buttresses, plinth and string course, fillets etc from top of foundation up to floor two level including finishing and plastering the exposed surfaces with cement mortar 1 : 3 (1 cement : 3 fine sand) of thickness not exceeding 6 mm to give a smooth and even surface excluding cost of centring, shuttering and reinforcement in : a) M20 (1 cement : 1.5 corase sand : 3 stone aggregate 20 mm nominal size)-RCC Walls
392Centring and shuttering including strutting, propping etc and removal of form work for a) Foundation, footings, bases of columns etc. and mass concrete-CC Bed for RCC Grit Chamber-Foundation Base Slab
393Centring and shuttering including strutting, propping etc and removal of form work for b) Walls (any thickness) including attached pilasters, buttresses, plinth and string courses etc.-RCC Walls
394Reinforcement of RCC work including bending, binding and placing in position complete.b) Tar/TMT steel-Reiforcement in Base-Reinforcement of RCC Walls
395Construction of Chlorination Tank
396Earth work in excavation in foundation and trenches etc. in all kinds of soil (excluding soil containing 50% or more of shingle or small size boulders upto 30 cm size, saturated soil and rock) lift upto 1.50m and stacking the excavated soil not more than 3m clear from the edge of the excavation and returning the stacked soil in 15 cm layers, when required into plinth sides of foundation etc. consolidating each deposited layer by arming and watering of all surplus soil as directed within a lead of 50m -% of the above Quantity.
397Earth work in excavation in foundation and trenches etc. in all kinds of soil (excluding soil containing 50% or more of shingle or small size boulders upto 30 cm size, saturated soil and rock) lift upto 1.50m and stacking the excavated soil not more than 3m clear from the edge of the excavation and returning the stacked soil in 15 cm layers, when required into plinth sides of foundation etc. consolidating each deposited layer by arming and watering of all surplus soil as directed within a lead of 50m -% of the above Quantity.
398Filling with sand including watering, ramming, consolidating and dressing complete.-Sand Bed below CC bed
399Providing and laying in foundations and plinth cement concrete 1 : 4 : 8 (1 cement : 4 coarse sand : 8 graded stone aggregate 40 mm nominal size) excluding the cost of centring and shuttering.-CC Bed
400Reinforced concrete work in foundations, footings, bases of columns etc. and mass concrete excluding cost of centring, shuttering and reinforcement in : a) M20 (1 cement : 1.5 coarse sand : 3 stone aggregate 20 mm nominal size).-For Base slab
401Reinforced cement concrete in walls (any thickness) including attached pillasters,buttresses, plinth and string course, fillets etc from top of foundation up to floor two level including finishing and plastering the exposed surfaces with cement mortar 1 : 3 (1 cement : 3 fine sand) of thickness not exceeding 6 mm to give a smooth and even surface excluding cost of centring, shuttering and reinforcement in : a) M20 (1 cement : 1.5 corase sand : 3 stone aggregate 20 mm nominal size)-For RCC walls
402Reinforced concrete work in foundations, footings, bases of columns etc. and mass concrete excluding cost of centring, shuttering and reinforcement in : a) M20 (1 cement : 1.5 coarse sand : 3 stone aggregate 20 mm nominal size).-Top Slab-Deduct Manhole
403Centring and shuttering including strutting, propping etc and removal of form work for a) Foundation, footings, bases of columns etc. and mass concrete-CC Bed-For Base slab -For RCC walls
404Centring and shuttering including strutting, propping etc and removal of form work for b) Walls (any thickness) including attached pilasters, buttresses, plinth and string courses etc.-For RCC walls
4056 mm cement plaster 1 : 3 (1 cement : 3 fine sand) finished with a floating coat of neat cement and thick coat of lime wash on top of walls when dry for bearing of RCC slabs and beams.-Intternal Platering-External Plastering
406Applying Two coats of Corroseal Epoxy Resin based Coating in one base coat and One top coats over the thoroughly prepared interior surfaces as directed by departmental officers, with each coat not exceeding 60 microns in dry film thickness and total film thickness to 240 microns including cost and conveyance of all materials to site, all labour charges ,curing and all other incidental charges etc complete for finished item of work-As per plastering Qty (Q)
407Painting two or more coats with enamel paint of approved brand and manufacture in any shade on new work to give an even shade.-External Painting above GL
408Reinforcement of RCC work including bending, binding and placing in position complete.b) Tar/TMT steel-For Base slab -For RCC walls -Top Slab
409Construction of Office and Electrical Panel Room of Size 5.5m x3.0m
410Earth work in excavation in foundation and trenches etc. in all kinds of soil (excluding soil containing 50% or more of shingle or small size boulders upto 30 cm size, saturated soil and rock) lift upto 1.50m and stacking the excavated soil not more than 3m clear from the edge of the excavation and returning the stacked soil in 15 cm layers, when required into plinth sides of foundation etc. consolidating each deposited layer by arming and watering of all surplus soil as directed within a lead of 50m -in all types of soils
411Earth work in excavation in foundation and trenches etc. in all kinds of soil (excluding soil containing 50% or more of shingle or small size boulders upto 30 cm size, saturated soil and rock) lift upto 1.50m and stacking the excavated soil not more than 3m clear from the edge of the excavation and returning the stacked soil in 15 cm layers, when required into plinth sides of foundation etc. consolidating each deposited layer by arming and watering of all surplus soil as directed within a lead of 50m -in Hard rocky soils
412Earth work in excavation in foundation and trenches etc. in all kinds of soil (excluding soil containing 50% or more of shingle or small size boulders upto 30 cm size, saturated soil and rock) lift upto 1.50m and stacking the excavated soil not more than 3m clear from the edge of the excavation and returning the stacked soil in 15 cm layers, when required into plinth sides of foundation etc. consolidating each deposited layer by arming and watering of all surplus soil as directed within a lead of 50m -in all types of soils
413Earth work in excavation in foundation and trenches etc. in all kinds of soil (excluding soil containing 50% or more of shingle or small size boulders upto 30 cm size, saturated soil and rock) lift upto 1.50m and stacking the excavated soil not more than 3m clear from the edge of the excavation and returning the stacked soil in 15 cm layers, when required into plinth sides of foundation etc. consolidating each deposited layer by arming and watering of all surplus soil as directed within a lead of 50m -in Hard rocky soils
414Providing and laying cement concrete 1 : 3 : 6 (1 cement : 3 coarse sand : 6 graded stone aggregate 40 mm nominal size) excluding the cost of centring an shuttering in:a) Foundations and plinth-Columns Footings-for foundations of Basement-Flooring-Flooring of office room-Ramp portion
415Reinforced concrete work in foundations, footings, bases of columns etc. and mass concrete excluding cost of centring, shuttering and reinforcement in : a) M20 (1 cement : 1.5 coarse sand : 3 stone aggregate 20 mm nominal size).-Column footing.
416Reinforced concrete work in foundations, footings, bases of columns etc. and mass concrete excluding cost of centring, shuttering and reinforcement in : a) M20 (1 cement : 1.5 coarse sand : 3 stone aggregate 20 mm nominal size).-Pedastals
417Reinforced cement concrete work in lintels, beams and bresumers up to floor two level including finishing and plastering the exposed surface with cement mortar 1 : 3 (1cement : 3 fine sand) of thickness not exceeding 6 mm to give a smooth and even surface but excluding cost of centering, shuttering and reinforcement.a) M20 (1 cement : 1.5 coarse sand : 3 stone aggregate 20 mm nominal size).-Plinth Beam
418Reinforcement cement concrete work in columns, pillars, piers, abutments, post and struts etc up to floor two level including finishing and plastering the exposed surface with cement mortar 1 : 3 (1 cement : 3 fine sand) of thickness not exceeding 6 mm to give a smooth and even surface but exluding cost of centring, shuttering and reinforcement.a) M20 (1 cement : 1.5 coarse sand : 3 stone aggregate 20 mm nominal size).-Columns up to 3.66 Mts unsupported height above GL
419Reinforced cement concrete work in lintels, beams and bresumers up to floor two level including finishing and plastering the exposed surface with cement mortar 1 : 3 (1cement : 3 fine sand) of thickness not exceeding 6 mm to give a smooth and even surface but excluding cost of centering, shuttering and reinforcement.a) M20 (1 cement : 1.5 coarse sand : 3 stone aggregate 20 mm nominal size).-Lintals
420Reinforced cement concrete in chajjas exceeding 15mm in thickness upto floor two level including centring and shuttering complete but excluding the cost of reinforcement with M20 ( 1 cement: 1.5 coarse sand : 3 stone aggregate 20 mm nominal size).-RCC M20 for Sun shades of 0.60M width, 75mm th. at fixed end and 50mm th. at free end
421Reinforced cement concrete work in lintels, beams and bresumers up to floor two level including finishing and plastering the exposed surface with cement mortar 1 : 3 (1cement : 3 fine sand) of thickness not exceeding 6 mm to give a smooth and even surface but excluding cost of centering, shuttering and reinforcement.a) M20 (1 cement : 1.5 coarse sand : 3 stone aggregate 20 mm nominal size).-Roof Beams
422Reinforced cement concrete in suspended floors, roofs, landings and balconies upto floor two level including finishing and plastering the exposed surface with cement mortar 1 : 3 (1 cement : 3 fine sand) of thickness not exceeding 6 mm to give a smooth and even surface but excluding cost of centring and shuttering and reinforcement with M20 (1 cement : 1.5 coarse sand : 3 stone aggregate 20 mm nominal size).-Roof Slab - 125mm thick
423Coursed rubble masonry (first sort) with hard stone in foundations and plinth in cement mortar 1 : 6 (1 cement : 6 fine sand).-Ist Step below G.L(foundations)-2nd Step above GL(basement)
424Brick work with best available local bricks in foundations and plinth in cement mortar 1:6 (1 cement : 6 fine sand).-Right round the building
425Half brick masonry (with best available local bricks) in cement mortar 1:4 (1 cement : 4coarse sand) in foundation and plinth.-Partiton wall-Parapet wall
4266 mm cement plaster to ceiling 1 : 3 (1 cement : 3 fine sand).-to ceiling and bottom and sides of beams
42712 mm cement plaster 1 : 3 (1 cement : 3 fine sand).-Internal long walls-Internal short walls-Partiton wall
42815 mm cement plaster 1 : 3 (1 cement : 3 fine sand) on the rough side of single or half brick wall.-External long walls-External short walls-Sun shades on both faces-both sides of the parapet wall
429Colour washing such as green, blue or buff on new work (two or more coats) including abase coat of white washing with lime to give an even shade.-Qty as ceiling plastering-Qty as per Internal Plastering
430Colour washing such as green, blue or buff on new work (two or more coats) including abase coat or white washing with whiting to give an even shade.-Qty as external plastering
431Cement concrete flooring 1 : 2 : 4 (1 cement : 2 coarse sand : 4 graded stone shingle 20mm nominal size) finished with a floating coat of neat cement.b) 50 mm thick-office room
432Entry / Exit Door Shutters :- Providing and fixing 37 mm thick factory made PVC Doorshutter, styles and rails made of PVC hollow extruded printed and laminated section having overall dimension 115 mm x 37 mm with wall thickness 2 mm (± 0.2 mm) with inbuilt beading on one side, the styles and rails mitred cut and joint at corners by inserting 2 nos PVC profile reinforcement of size 75 mm x 200 mm long with cross section size of 28 mm x 30 mm having wall thickness 2 mm (± 0.2 mm). Styles, rails and reinforcements to be fusion welded together. Only hinge side vertical style to be einforced with PVC profile reinforcement in full length. Printed and laminated PVC lock rail of size 110 mm x 37 mm having wall thickness 2 mm (± 0.2 mm) to be welded horizontally with the vertical styles after inserting PVC profile reinforcement as in styles and rails, providing with PVC snap fit beading, panels of 100 x 20 mm printed & laminated and inserting 2 nos 6 mm dia bright steel rod horizontally with both side threaded and tightened with check nuts and washers complete, all as per manufacturer's specification and direction of engineer-in-charge.-Doors
433Window / Ventilator Shutters:- Providing and fixing factory made uPVC white colour casement/ casement cum fixed glazed windows comprising of uPVC multi chambered frame, sash and mullion (where ever required) extruded profiles duly reinforced with 1.60 ± 0.2 mm thick galvanized mild steel section made from roll forming process of required length (shape & size according to uPVC profile), uPVC extruded glazing beads of appropriate dimension, EPDM gasket, stainless steel (SS 304 grade) friction hinges,zinc alloy (white powder coated) casement handles, G.I fasteners 100 x 8 mm size for fixing frame to finished wall, plastic packers, plastic caps and necessary stainless steel screws etc. Profile of frame & sash shall be mitred cut and fusion welded at all corners,mullion (if required) shall be also fusion welded including drilling of holes for fixing hardware's and drainage of water etc. After fixing frame the gap between frame and adjacent finished wall shall be filled with weather proof silicon sealant over backer rod of required size and of approved quality, all complete as per approved drawing & direction of Engineer-in-Charge. (Single / double glass panes and silicon sealant shall be paid separately) -Windows
434Providing precast cement concrete jali M20 (1 cement : 1.5 coarse sand : 3 stone aggregate 20 mm nominal size) reinforced with 1.6 mm dia mild steel wire including,roughening, cleaning, fixing and finishing in cement mortar 1 : 3 (1 cement : 3 fine sand) etc complete upto floor two level excluding plastering of the jams, sills and soffits.a) 50 mm thick-
435Centring and shuttering including strutting, propping etc and removal of form work for a) Foundation, footings, bases of columns etc. and mass concrete-Column footing.-Pedastals-Plinth Beam
436Centring and shuttering including strutting, propping etc and removal of form work for e) Column, pillars, posts and struts etc.-Columns up to GL-Columns above GL up to plinth beam top level-Columns above plinth beam top level to slab top level-Columns Above slab level
437Centring and shuttering including strutting, propping etc and removal of form work for d) Lintels, beams, girders, bressumers and cantilevers etc.-over windows-Roof Beams
438Centring and shuttering including strutting, propping etc and removal of form work forc) Suspended floors, roofs, landings shelves and their supports, balconies and chajjas (3.5 m height).-Roof Slab - 125mm thick
439Reinforcement of RCC work including bending, binding and placing in position complete.
440Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m.-Basement
441Sanitory as per seprate estimate
442Electrification as per seprate estimate
443Providing and installation of Generator set
444Supply, Transportation, erection and commissioning (Excluding Foundation) of 3 Phase, 415, 50Hz, water cooled multi cylinder diesel generator set with alternator of - - - KVA/ - - - - - KW out put contineous rating directly coupled Engine and Alternator with guard and mounted on a common base plate of Robust construction and complete without control panel having IP-52 protection, Acoustic Enclosure as per CPCB norms , sound absorbing material, t to restrict sound level up to 75 dB up to 1 mtr distance and as per CPCB norms etc as per following specifications mentioned below. A. Alternator : Kirloskar / Stamford / Crompton Greaves / Leroy Somer make. The alternator of the output rating shall be 3 Phase, 415V, 50Hz, Ac , 0.8 P.F. lagging at 1500 RPM. The alternator is self excited, self regulated, and shall confirm to IS: 13364 of 1992 with regulation of +5% from no load to full load. degree of protections shall be IP21.B.Diesel Engine : Kirloskar / Cummins / Mahindra & Mahindra Diesel Engine start, developing suitable -------------- BHP output at 1500 RPM with mechanical / electronic governing so as to enable the alternator to give - - - - -KVA continuous output at 0.8 P.F. lagging at NTP conditions. The diesel engine shall be capable of providing 10% O/L for 1 Hr for every 11 Hrs of continuous running at full load. The engine with 1st filling of oil and Diesel etc. 01. Exhaust pipe of required size and length with insulation or clading. 02. Diesel tank suitable for 8 to 12 Hours running capacity.03. Residential Silencer.04. SMF Batteries with leads as per the Manufacturer standards
445C. AMF Control Panel:- AMF control panel shall be fabricated with 16SWG CRCA sheet shall be totally enclosed with dust and Vermin proof, floor mounted / wall mounted type and shall be comprising the following.01. Voltmeter with selector switch.02. 4 Pole MCCB incomer of ----------A rating of Schenieder / L&T make for EB and DG.03. Ammeter with selector switch with CTs.04. PF Meter and frequency Meter.05. Indicator lamps (set Run, Load ON) with fuses.06. KWH Meter of required rating.07. Set of control fuses and current transformer.08. Input Terminal board and output Terminal Board.09. Battery charger with transformer rectifier unit.10. Alternator supply air break contactor of L&T make.11. Main supply air break contactor of L&T make.12. Audio Visual announciation.13. Main supply voltage set of control relays and timers with one mode selector switch, set of push buttons.14.Control cable up to 15 Mtrs 2.5Sqmm 6 Core
44615 KVA, 3 Phase, 415, 50Hz, 19BHP, water cooled multi cylinder diesel generator set with alternator of 15 KVA out put continous rating at 0.8 p.f, Batteries .- 63.00 KVA
447Supply of 185 Sqmm of 3.5core XLPE insulated, 1100V grade armoured alluminium cable with ISI mark as per specification confirming to IS:7098 (Part - I) Makes : Torrent / Unicab / Universal / Polycab / Havells / Gloster / KEI /Finolex / Payal / RR kable / Beljin /Ollvin / Finecab / RPG / V - Guard / Orbit/ Fortune Arrt / Gemscab / Bonton / SPM/ Unistar / Windsor/Avocab / Pawancab/ Nakoda / Suncab
448Earth work excavation in all soils, laying of UG cables from 70 Sqmm to 400 Sqmm on sand cussion, covering the cable with bricks and back filling the trench duly providing route indicator embedded in CC including cost and conveyance of all material and all labour charges etc, complete.
449Filling with sand including watering, ramming, consolidating and dressing complete.-Below Bed Concrete
450Providing and laying in foundations and plinth cement concrete 1 : 4 : 8 (1 cement : 4 coarse sand : 8 graded stone aggregate 40 mm nominal size) excluding the cost of centring and shuttering.-for foundation of Generator bed
451Providing and laying cement concrete 1 : 3 : 6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) excluding the cost of centring and shuttering in : a) Foundations and plinth-for Generator bed
452Reinforcement of RCC work including bending, binding and placing in position complete.b) Tar/TMT steel-at 35Kg/ 1 Cum
453Earthing with G.I. earth pipe 4.5 metre long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal/ coke and salt as required.-Earthing
454Supply, Delivery, Installation Testing of Pumps Sets at Bio Tower 2 KW-2Nos (2 Working 1 Standby)
455SUBMERSIBLE SEWAGE NON-CLOG VERTICAL PUMPSupply, delivery, installation, testing and commissioning of Submersible sewage, Non clog vertical type pump suitable for working on Air filled Dry type motor, three phase, 50 Hz +/-3%, 415V +/- 10%, AC supply, 1500 RPM synchronous speed with 3 core flat copper cable from pump to starter panel with cable end terminations (4) all supports, clamps, pipe fittings along with mechanical seal, bearing bush, strainer, arrangements for lifting for maintenance, guide pipes etc. complete set & following M.O.C: Casing CI, SS CF8M impeller, Bronze: wearing ring & Bearing bush, TC mechanical seal, CS/S.S. bearing, S.S shaft with sleeve, SS strainer & MS motor body, including compatible panel board consisting of Auto Transformer Starter suitable for local & remote pump control application consisting of Auto Transformer (vacuum impregnated, air cooled having three (3) tappings at 50%, 65% and 80%), incomer MCCB / MPCB, overload relay and contactors as per Type II coordination including digital MFM with RS 485 communication port, analogue type ammeter with selector switch, run hour meter, required protective relays & control accessories.STANDARD ACCESSORIESSupply, Delivery and Installation of Standard accessories including Power cable of PVC+Cu length 5mtrs, Pedestal auto rail coupling of Cast Iron(CI),Single Rail GR pipe of SS304 length 10Mtr and along with GRP coupler, Lifting chain with bow shackles and control panel including auto transformer starter Including Suction pipe dilavery pipe up to manifold sutuable Valves ,NRV,Pressure Gauge,Manifold etc. Total Head 11.5m
456Providing Filter Media at Bio Tower with sprinkling system, piping arrangements including valves, Bends, Tees etc complete item of work
457Construction of Wet well of 2m dia and 6.5m depth
458Earth work in excavation in foundation and trenches etc. in all kinds of soil (excluding soil containing 50% or more of shingle or small size boulders upto 30 cm size, saturated soil and rock) lift upto 1.50m and stacking the excavated soil not more than 3m clear from the edge of the excavation and returning the stacked soil in 15 cm layers, when required into plinth sides of foundation etc. consolidating each deposited layer by arming and watering of all surplus soil as directed within a lead of 50m -in all types of soils
459Earth work in excavation in foundation and trenches etc. in all kinds of soil (excluding soil containing 50% or more of shingle or small size boulders upto 30 cm size, saturated soil and rock) lift upto 1.50m and stacking the excavated soil not more than 3m clear from the edge of the excavation and returning the stacked soil in 15 cm layers, when required into plinth sides of foundation etc. consolidating each deposited layer by arming and watering of all surplus soil as directed within a lead of 50m -10% of the Total Qty-EWE from 3 to 6 metres by Mechanical means
460Earth work in excavation in foundation and trenches etc. in all kinds of soil (excluding soil containing 50% or more of shingle or small size boulders upto 30 cm size, saturated soil and rock) lift upto 1.50m and stacking the excavated soil not more than 3m clear from the edge of the excavation and returning the stacked soil in 15 cm layers, when required into plinth sides of foundation etc. consolidating each deposited layer by arming and watering of all surplus soil as directed within a lead of 50m -10% of the Total Qty-EWE from above 6 metres by Mechanical means
461Filling with sand including watering, ramming, consolidating and dressing complete.-For WET WELL (π/4x3.4^2)
462Providing and laying in foundations and plinth cement concrete 1 : 4 : 8 (1 cement : 4 coarse sand : 8 graded stone aggregate 40 mm nominal size) excluding the cost of centring and shuttering.-For WET WELL (π/4x3.4^2)
463Reinforced cement concrete in walls (any thickness) including attached pillasters,buttresses, plinth and string course, fillets etc from top of foundation up to floor two level including finishing and plastering the exposed surfaces with cement mortar 1 : 3 (1 cement : 3 fine sand) of thickness not exceeding 6 mm to give a smooth and even surface excluding cost of centring, shuttering and reinforcement in : a) M20 (1 cement : 1.5 corase sand : 3 stone aggregate 20 mm nominal size)-Base Slab
464Reinforced cement concrete in walls (any thickness) including attached pillasters,buttresses, plinth and string course, fillets etc from top of foundation up to floor two level including finishing and plastering the exposed surfaces with cement mortar 1 : 3 (1 cement : 3 fine sand) of thickness not exceeding 6 mm to give a smooth and even surface excluding cost of centring, shuttering and reinforcement in : a) M20 (1 cement : 1.5 corase sand : 3 stone aggregate 20 mm nominal size)-1st Step 0.4m Sidewalls of WET WELL (πx2.4) Below Ground
465Reinforced cement concrete in walls (any thickness) including attached pillasters,buttresses, plinth and string course, fillets etc from top of foundation up to floor two level including finishing and plastering the exposed surfaces with cement mortar 1 : 3 (1 cement : 3 fine sand) of thickness not exceeding 6 mm to give a smooth and even surface excluding cost of centring, shuttering and reinforcement in : a) M20 (1 cement : 1.5 corase sand : 3 stone aggregate 20 mm nominal size)-Sidewalls from 5.5 to 4.5m Below GL
466Reinforced cement concrete in walls (any thickness) including attached pillasters,buttresses, plinth and string course, fillets etc from top of foundation up to floor two level including finishing and plastering the exposed surfaces with cement mortar 1 : 3 (1 cement : 3 fine sand) of thickness not exceeding 6 mm to give a smooth and even surface excluding cost of centring, shuttering and reinforcement in : a) M20 (1 cement : 1.5 corase sand : 3 stone aggregate 20 mm nominal size)-2nd Step 0.3m Sidewalls of WET WELL (πx2.3) Below Ground
467Reinforced cement concrete in walls (any thickness) including attached pillasters,buttresses, plinth and string course, fillets etc from top of foundation up to floor two level including finishing and plastering the exposed surfaces with cement mortar 1 : 3 (1 cement : 3 fine sand) of thickness not exceeding 6 mm to give a smooth and even surface excluding cost of centring, shuttering and reinforcement in : a) M20 (1 cement : 1.5 corase sand : 3 stone aggregate 20 mm nominal size)-Sidewalls from 3.5 to 2.5m Below GL
468Reinforced cement concrete in walls (any thickness) including attached pillasters,buttresses, plinth and string course, fillets etc from top of foundation up to floor two level including finishing and plastering the exposed surfaces with cement mortar 1 : 3 (1 cement : 3 fine sand) of thickness not exceeding 6 mm to give a smooth and even surface excluding cost of centring, shuttering and reinforcement in : a) M20 (1 cement : 1.5 corase sand : 3 stone aggregate 20 mm nominal size)-3rd Step 0.2m Sidewalls of WET WELL (πx2.2) Below Ground
469Reinforced cement concrete in walls (any thickness) including attached pillasters,buttresses, plinth and string course, fillets etc from top of foundation up to floor two level including finishing and plastering the exposed surfaces with cement mortar 1 : 3 (1 cement : 3 fine sand) of thickness not exceeding 6 mm to give a smooth and even surface excluding cost of centring, shuttering and reinforcement in : a) M20 (1 cement : 1.5 corase sand : 3 stone aggregate 20 mm nominal size)-Floor level Beams at +1.0m
470Reinforced cement concrete in walls (any thickness) including attached pillasters,buttresses, plinth and string course, fillets etc from top of foundation up to floor two level including finishing and plastering the exposed surfaces with cement mortar 1 : 3 (1 cement : 3 fine sand) of thickness not exceeding 6 mm to give a smooth and even surface excluding cost of centring, shuttering and reinforcement in : a) M20 (1 cement : 1.5 corase sand : 3 stone aggregate 20 mm nominal size)-Floor Roof Slab 150 thick @1.0m Height ( Half of the Dia)
471Centring and shuttering including strutting, propping etc and removal of form work for a) Foundation, footings, bases of columns etc. and mass concrete-PCC Below Base Slab-For WET WELL (π/4x3.4^2)
472Extra for shuttering in circular work. -Add 20% of the rate of respective item of centring and shuttering.
4733rd Step 0.2m Sidewalls of WET WELL (πx2.2) Below Ground-1st Step 0.4m Sidewalls of WET WELL (πx2.4) Below Ground-2nd Step 0.3m Sidewalls of WET WELL (πx2.3) Below Ground-3rd Step 0.2m Sidewalls of WET WELL (πx2.2) Below Ground
474Extra for shuttering in circular work. Add 20% of the rate of respective item of centring and shuttering.
475Centring and shuttering including strutting, propping etc and removal of form work for c) Suspended floors, roofs, landings shelves and their supports, balconies and chajjas (3.5 m height).-Floor Roof Slab 150 thick @1.0m Height ( Half of the Dia)-For WET WELL (π/4x2.8^2)-For Slab Sides
476Centring and shuttering including strutting, propping etc and removal of form work for d) Lintels, beams, girders, bressumers and cantilevers etc.-Floor level Beams at +1.0m- B1 (300x450)
477Reinforcement of RCC work including bending, binding and placing in position complete.b) Tar/TMT steel
4786 mm cement plaster 1 : 3 (1 cement : 3 fine sand) finished with a floating coat of neat cement and thick coat of lime wash on top of walls when dry for bearing of RCC slabs and beams.-Internal Plastering-External Plastering above GL
479Extra for shuttering in circular work. Add 20% of the rate of respective item of centring and shuttering.
480Applying Two coats of Corroseal Epoxy Resin based Coating in one base coat and One top coats over the thoroughly prepared interior surfaces as directed by departmental officers, with each coat not exceeding 60 microns in dry film thickness and total film thickness to 240 microns including cost and conveyance of all materials to site, all labour charges ,curing and all other incidental charges etc complete for finished item of work-As per plastering Qty (Q)
481Painting two or more coats with enamel paint of approved brand and manufacture in any shade on new work to give an even shade.-External Painting above GL
482Steel work welded in built up sections/ framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required.b) In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works-for Lader
483Construction of I&D Structures
484Cutting of Trees, including Cutting of Trunks, Branches and Removal (Cutting of trees, including cutting of trunks, branches and removal of stumps, roots, stacking of serviceable material with all lifts and up to a lead of 1000 mtrs and earth filling in the depression/pit.)-Girth from 300 mm to 600 mm
485Cutting of Trees, including Cutting of Trunks, Branches and Removal (Cutting of trees, including cutting of trunks, branches and removal of stumps, roots, stacking of serviceable material with all lifts and up to a lead of 1000 mtrs and earth filling in the depression/pit.)-Girth from 600 mm to 900 mm
486Cutting of Trees, including Cutting of Trunks, Branches and Removal (Cutting of trees, including cutting of trunks, branches and removal of stumps, roots, stacking of serviceable material with all lifts and up to a lead of 1000 mtrs and earth filling in the depression/pit.)-Girth from 900 mm to 1800 mm
487Demolishing brick work in cement mortar including stacking of serviceable material and disposal of unserviceable material within 50 metres lead.-Dismantling of existing structure
488Demolishing RCC work including stacking of steel bars and disposal of un-serviceable materials within 50 metres lead.-CC Walls, beds etc,.
489Earth work in excavation in foundation and trenches etc. in all kinds of soil (excluding soil containing 50% or more of shingle or small size boulders upto 30 cm size, saturated soil and rock) lift upto 1.50m and stacking the excavated soil not more than 3m clear from the edge of the excavation and returning the stacked soil in 15 cm layers, when required into plinth sides of foundation etc. consolidating each deposited layer by arming and watering of all surplus soil as directed within a lead of 50m -in all types of soils for footings
490Earth work in excavation in foundation and trenches etc. in all kinds of soil (excluding soil containing 50% or more of shingle or small size boulders upto 30 cm size, saturated soil and rock) lift upto 1.50m and stacking the excavated soil not more than 3m clear from the edge of the excavation and returning the stacked soil in 15 cm layers, when required into plinth sides of foundation etc. consolidating each deposited layer by arming and watering of all surplus soil as directed within a lead of 50m -10% of the Total Qty
491Filling with sand including watering, ramming, consolidating and dressing complete.-Below CC bed for RCC drain
492Providing and laying in foundations and plinth cement concrete 1 : 4 : 8 (1 cement : 4 coarse sand : 8 graded stone aggregate 40 mm nominal size) excluding the cost of centring and shuttering.-CC Bed below foundation
493Reinforced concrete work in foundations, footings, bases of columns etc. and mass concrete excluding cost of centring, shuttering and reinforcement in : a) M20 (1 cement : 1.5 coarse sand : 3 stone aggregate 20 mm nominal size).-Foundation Base Slab-Weir
494Reinforced cement concrete in walls (any thickness) including attached pillasters,buttresses, plinth and string course, fillets etc from top of foundation up to floor two level including finishing and plastering the exposed surfaces with cement mortar 1 : 3 (1 cement : 3 fine sand) of thickness not exceeding 6 mm to give a smooth and even surface excluding cost of centring, shuttering and reinforcement in : a) M20 (1 cement : 1.5 corase sand : 3 stone aggregate 20 mm nominal size)-RCC Walls
495Centring and shuttering including strutting, propping etc and removal of form work for a) Foundation, footings, bases of columns etc. and mass concrete-CC Bed below foundation-Foundation Base Slab
496Centring and shuttering including strutting, propping etc and removal of form work for b) Walls (any thickness) including attached pilasters, buttresses, plinth and string courses etc.-Weir-RCC Walls
497Reinforcement of RCC work including bending, binding and placing in position complete.b) Tar/TMT steel-Reiforcement in Base-Reinforcement of RCC Walls
49825 Providing and fixing stainless steel ( Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners , stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in-charge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.).-Coarse Screen-Medium Screen
499Construction of elevated RCC Bridge with RCC NP2 Pipe
500Earth work in excavation in foundation and trenches etc. in all kinds of soil (excluding soil containing 50% or more of shingle or small size boulders upto 30 cm size, saturated soil and rock) lift upto 1.50m and stacking the excavated soil not more than 3m clear from the edge of the excavation and returning the stacked soil in 15 cm layers, when required into plinth sides of foundation etc. consolidating each deposited layer by arming and watering of all surplus soil as directed within a lead of 50m -in all types of soils for footings
501Earth work in excavation in foundation and trenches etc. in all kinds of soil (excluding soil containing 50% or more of shingle or small size boulders upto 30 cm size, saturated soil and rock) lift upto 1.50m and stacking the excavated soil not more than 3m clear from the edge of the excavation and returning the stacked soil in 15 cm layers, when required into plinth sides of foundation etc. consolidating each deposited layer by arming and watering of all surplus soil as directed within a lead of 50m -10% of the Total Qty
502Filling with sand including watering, ramming, consolidating and dressing complete.-Below CC bed
503Providing and laying in foundations and plinth cement concrete 1 : 4 : 8 (1 cement : 4 coarse sand : 8 graded stone aggregate 40 mm nominal size) excluding the cost of centring and shuttering.-CC Bed
504Reinforced concrete work in foundations, footings, bases of columns etc. and mass concrete excluding cost of centring, shuttering and reinforcement in : a) M20 (1 cement : 1.5 coarse sand : 3 stone aggregate 20 mm nominal size).-Footings
505Reinforced concrete work in foundations, footings, bases of columns etc. and mass concrete excluding cost of centring, shuttering and reinforcement in : a) M20 (1 cement : 1.5 coarse sand : 3 stone aggregate 20 mm nominal size).-Pedastal
506Reinforcement cement concrete work in columns, pillars, piers, abutments, post and struts etc up to floor two level including finishing and plastering the exposed surface with cement mortar 1 : 3 (1 cement : 3 fine sand) of thickness not exceeding 6 mm to give a smooth and even surface but exluding cost of centring, shuttering and reinforcement.a) M20 (1 cement : 1.5 coarse sand : 3 stone aggregate 20 mm nominal size).-Columns upto GL-Columns Above GL
507Reinforced cement concrete work in lintels, beams and bresumers up to floor two level including finishing and plastering the exposed surface with cement mortar 1 : 3 (1cement : 3 fine sand) of thickness not exceeding 6 mm to give a smooth and even surface but excluding cost of centering, shuttering and reinforcement.a) M20 (1 cement : 1.5 coarse sand : 3 stone aggregate 20 mm nominal size).-Roof Beam
508Reinforced cement concrete in suspended floors, roofs, landings and balconies upto floor two level including finishing and plastering the exposed surface with cement mortar 1 : 3 (1 cement : 3 fine sand) of thickness not exceeding 6 mm to give a smooth and even surface but excluding cost of centring and shuttering and reinforcement with M20 (1 cement : 1.5 coarse sand : 3 stone aggregate 20 mm nominal size).-Roof Slab
509Centring and shuttering including strutting, propping etc and removal of form work for a) Foundation, footings, bases of columns etc. and mass concrete-CC Bed -Footings-Pedastal
510Centring and shuttering including strutting, propping etc and removal of form work for e) Column, pillars, posts and struts etc.-Columns upto GL-Columns Above GL
511Centring and shuttering including strutting, propping etc and removal of form work for d) Lintels, beams, girders, bressumers and cantilevers etc.-Roof Beam-Roof Beam Bottom-Roof Beam Sides
512Centring and shuttering including strutting, propping etc and removal of form work forc) Suspended floors, roofs, landings shelves and their supports, balconies and chajjas (3.5 m height).-Roof Slab-Roof Bottom-Roof Sides
513Reinforcement of RCC work including bending, binding and placing in position complete.b) Tar/TMT steel
514Providing and Layng light duty non-pressure NP2 Class RCC pipes with collars jointed with stiff mixture of cement mortar in the proportion of 1:2 (1 Cement : 2 fine sand) including testing joints etc complete.-250mm dia RCC Pipe (NP2)
515Supplying, laying and lowering of DI K7 Pipe for Pumping Main
516Earth work in excavation in foundation and trenches etc. in all kinds of soil (excluding soil containing 50% or more of shingle or small size boulders upto 30 cm size, saturated soil and rock) lift upto 1.50m and stacking the excavated soil not more than 3m clear from the edge of the excavation and returning the stacked soil in 15 cm layers, when required into plinth sides of foundation etc. consolidating each deposited layer by arming and watering of all surplus soil as directed within a lead of 50m
517Excavation in Ordinary Rockusing Hydraulic ExcavatorCK-90 and Tippers with disposal upto 1000 metres. (Excavation for roadway in ordinary rock with hydraulic excavator of 0.9 cum bucket capacity including cutting and loading in tippers, transporting to embankment site within all lifts and lead upto 1000 m, trimming bottom and side slopes in accordance with requirements of lines, grades and cross sections.)
518Excavation in Hard Rock (blasting prohibited) (Excavation for roadway in hard rock (blasting prohibited) with rock breakers including breaking rock,loading in tippers and disposal within all lifts and lead upto 1000 metres,trimming bottom and side slopes in accordance with requirements of lines,grades and cross sections.)Mechanised
519Earth work in excavation in foundation and trenches etc. in all kinds of soil (excluding soil containing 50% or more of shingle or small size boulders upto 30 cm size, saturated soil and rock) lift upto 1.50m and stacking the excavated soil not more than 3m clear from the edge of the excavation and returning the stacked soil in 15 cm layers, when required into plinth sides of foundation etc. consolidating each deposited layer by arming and watering of all surplus soil as directed within a lead of 50m
520Providing, laying, jointing and testing S&S Centrifugally Cast Ductile Iron double chamber Class K-7 pressure pipes conforming to IS 8329:2000 with restrained joints (bolt less), all complete.150 mm dia DI K7 pipe
521Providing and laying D.I. specials of class K-12 suitable for push-on jointing as per IS : 9523:
522Providing and fixing C.I. sluice valves (with cap) complete with bolts, nuts, rubber insertions etc. (the tail pieces if required will be paid separately) :
523Providing and fixing C.I. sluice valves (with cap) complete with bolts, nuts, rubber insertions etc. (the tail pieces if required will be paid separately) :
524Internal & External electrification with Transformer
525Fabrication and Supply of M.S. Poles for garden posts with 'B' class 6 mtrs long 60.25mm outer dia with base plate and suitable pole cap including cost and conveyance of all material including fixing of luminaire and labour charges etc., complete. 6Mtrs 'B' Class M.S. pipe of 60.25mm dia with base plate and suitable pole cap
526Erection of steel tubular or rail pole strut in cement concrete 1:3:6 (1 cement: 3 coarse sand: 6 graded stone aggregate 40 mm nominal size) foundation including excavation and refilling and secured with holding clamps, bolts, nuts, etc. as required.
527Supplying and drawing (following size) of FRLS PVC insulated copper conductor single core cable in existing surface / I recessed steel / PVC conduit as required.
528Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, \\"C\\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioninq etc. as required.
529Laying of one number PVC insulated and PVC sheathed/XLPE power cable of 1.1 KV grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as required.
530Providing and fixing following capacity TP&N disconnector fuse switch unit inside the existing panel board with ISI marked HRC fuses including drilling holes in cubicle panel, making connections, etc. as required.100 A TP&N
531Providing and fixings 4 pole MCCB 100 amp. 16 KA in existing cubicle panel board including drilling holes in cubicle panel & making connection etc. as reqd.
532Earthing with G.I. earth pipe 4.5m long 40mm dia i/c accessories and providing masonary enclosure with cover plate having locking arrangement and watering pipe etc. (with charcoal or cokeL and salt) as read.
533Providing and laying in foundations and plinth cement concrete 1 : 4 : 8 (1 cement : 4 coarse sand : 8 graded stone aggregate 40 mm nominal size) excluding the cost of centring and shuttering.
534Supplying,installation,testing and commissioning of Astronomicaltime switch of following configuration to be mounted in feeder pillars / Lighting DBs for automatic switching On & OFF of street lights at sun set & sun rise or twilight(Auto ON, Auto OFF, Auto modes) with manual override facility with 12/24 hour display format with suitable battery and indication for relay status i/c programming at site complete as required.1 output per phase and suitable for single phase supply
535New generation energy saving andenvironmental friendly long life LED street light made up of pressure die castaluminum housing with high efficient LED as lighting source and PC cover having TOP Opening separate driver compartment with IP66 protection and impact resistance of IK07.70 W LED
536Providing of 10mmsqm 2-core & 6mmsqm 2-core PVC/XLPE Cables,Indicating Lamp,Voltmeter range 0-500 volts,Ammeter range 0-200 volts,Current transformer coil range 0-200 amp,Hinges for panel door,Panel door locksSelector switch for ammeter & voltmeter etc
537Erection of 25 KVA Transformer
538Providing and installation of Porta Cabin for Security Room
539Supplying and installation of MS Fabricated Portable Cabin With complete insulation, electrical & Plywood claddings etc, complete as per direction engineer incharge with following Technical Specifications: Portable Security Cabin ( both side finish ) Material- MS, ACP & particle Bord. Size – 6 Ft x 6 Ft Height – 7Ft Colour – White & Blue Aluminum Sliding Window -2 Nos Door – 1 Nos Electrical Switch Socket Board – 1 Nos Technical Specification1) 18 mm cement Board for floor2) 1mm MS sheet for outer3) 9mm Particle Board for interior4) 50 x 50 mm MS pipe structure 5) 40 x 20 mm MS Pipe 6) 1mm PVC carpet on floor7) Internal electrical fitting
540Providing 3.5m wide CC Road with 1m earthen shoulders on either side
541Excavation in Soil using Hydraulic Excavator CK 90 and Tippers with 3disposal upto 1000 metres. (Excavation for roadwork in soil with hydraulic excavator of0.9 cum bucket capacity including cutting and loading in tippers,trimming bottom and side slopes, in accordance with requirements of lines,grades and cross sections, and transporting to the embankment location within all lifts and lead upto 1000m)-EWE in ordinary soils- total Qty
542Construction of Embankment with Material Deposited from RoadwayCutting (Construction of embankment with approved materials deposited at site from roadway cutting and excavation from drain and foundation of other structures graded and compacted to meet requirement of table 300-2)-for formation of road 90% total Qty
543Embankment Construction with Material Obtained from Borrow Pits(Construction of embankment with approved material obtained from borrow pits with all lifts and leads, transporting to site, spreading, grading to required slope and compacting to meet requirement of table 300-2)-for formation of road
544Granular Sub-Base with Coarse Graded Material ( Table:- 400- 2)(Construction of granular sub-base by providing coarse graded material, spreading in uniform layers with motor grader on prepared surface, mixing by mix in place method with rotavator at OMC, and compacting with vibratory roller to achieve the desired density, complete as per clause 401) for grading- I Material-for the formation of new road
545Dry Lean Cement Concrete Sub- base (Construction of dry lean cement concrete Sub- base over a prepared sub-grade with coarse and fine aggregate conforming to IS: 383, the size of coarse aggregate not exceeding 25 mm, aggregate cement ratio not to exceed 15:1, aggregate gradation after blending to be as per table 600-1, cement content not to be less than 150 kg/ cum, optimum moisture content to be determined during trial length construction, concrete strength not to be less than 10 Mpa at 7 days, mixed in a batching plant, transported to site, laid with a paver with electronic sensor, compacting with 8-10 tonnes vibratory roller, finishing and curing.)
546Cement Concrete Pavement (Construction of un-reinforced, dowel jointed,plain cement concrete pavement over a prepared sub base with 43 grade cement @ 400 kg per cum, coarse and fine aggregate conforming to IS 383,maximum size of coarse aggregate not exceeding 25 mm, mixed in a batching and mixing plant as per approved mix design, for M40 Grade having minimum 28 days flexural strength of 4.5 Mpa, using approved admixtures, transported to site, laid with a fixed form or slip form paver,spread, compacted and finished in a continuous operation including provision of contraction, expansion, construction and longitudinal joints, joint filler, separation membrane, sealant primer, joint sealant, debonding strip,dowel bar, tie rod, admixtures as approved, curing compound, finishing to lines and grades as per drawing. )
547Construction of Subgrade and Earthen Shoulders (Construction ofsubgrade and earthen shoulders with approved material obtained from borrow pits with all lifts & leads, transporting to site, spreading, grading to required slope and compacted to meet requirement of table No. 300-2)
548Construction of Compound wall with Chain Link Fencing and MS Gate
549Earth work in excavation in foundation and trenches etc. in all kinds of soil (excluding soil containing 50% or more of shingle or small size boulders upto 30 cm size, saturated soil and rock) lift upto 1.50m and stacking the excavated soil not more than 3m clear from the edge of the excavation and returning the stacked soil in 15 cm layers, when required into plinth sides of foundation etc. consolidating each deposited layer by arming and watering of all surplus soil as directed within a lead of 50m in all types of soils for footings
550Earth work in excavation in foundation and trenches etc. in all kinds of soil (excluding soil containing 50% or more of shingle or small size boulders upto 30 cm size, saturated soil and rock) lift upto 1.50m and stacking the excavated soil not more than 3m clear from the edge of the excavation and returning the stacked soil in 15 cm layers, when required into plinth sides of foundation etc. consolidating each deposited layer by arming and watering of all surplus soil as directed within a lead of 50m 10% of the Total Qty
551Filling with sand including watering, ramming, consolidating and dressing complete.Below CC bed
552Providing and laying in foundations and plinth cement concrete 1 : 4 : 8 (1 cement : 4 coarse sand : 8 graded stone aggregate 40 mm nominal size) excluding the cost of centring and shuttering.CC Bed
553Reinforced concrete work in foundations, footings, bases of columns etc. and mass concrete excluding cost of centring, shuttering and reinforcement in : a) M20 (1 cement : 1.5 coarse sand : 3 stone aggregate 20 mm nominal size).Footings
554Reinforced concrete work in foundations, footings, bases of columns etc. and mass concrete excluding cost of centring, shuttering and reinforcement in : a) M20 (1 cement : 1.5 coarse sand : 3 stone aggregate 20 mm nominal size).Pedastal
555Reinforcement cement concrete work in columns, pillars, piers, abutments, post and struts etc up to floor two level including finishing and plastering the exposed surface with cement mortar 1 : 3 (1 cement : 3 fine sand) of thickness not exceeding 6 mm to give a smooth and even surface but exluding cost of centring, shuttering and reinforcement.a) M20 (1 cement : 1.5 coarse sand : 3 stone aggregate 20 mm nominal size).Columns upto GLColumns Above GL
556Centring and shuttering including strutting, propping etc and removal of form work for a) Foundation, footings, bases of columns etc. and mass concreteCC Bed FootingsPedastal
557Centring and shuttering including strutting, propping etc and removal of form work for e) Column, pillars, posts and struts etc.Columns upto GLColumns Above GL
558Reinforcement of RCC work including bending, binding and placing in position complete.b) Tar/TMT steelFootingsPedastalColumns upto GLColumns Above GL
559Steel work welded in built up sections/ framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required.b) In gratings, frames, guard bar, ladder, railings, brackets, gates and similar worksfor MS Gate
560Earth work in excavation in foundation and trenches in soils containing 50% or more of shingle or small size boulders upto 30 cm size, lift upto 1.50 m and stacking the excavated soil not more than 3 m clear from the edge of the excavation and returning the stacked soil in 15 cm layers when required, into plinth, sides of foundation etc consolidating each deposited layer by ramming and watering and then disposing of all surplus excavated soil as directed within a lead of 50m.for foundations of MS fencing posts - Mainfor foundations of MS fencing posts - Inclined support at every 30m
561Providing and laying in foundations and plinth cement concrete 1 : 5 : 10 (1 cement : 5 coarse sand : 10 graded stone aggregate 40 mm nominal size) excluding the cost of centring and shuttering.for foundations of MS fencing posts - Mainfor foundations of MS fencing posts - Inclined support at every 30m
562Reinforced concrete work in foundations, footings, bases of columns etc. and mass concrete excluding cost of centring, shuttering and reinforcement in : a) M20 (1 cement : 1.5 coarse sand : 3 stone aggregate 20 mm nominal size).for foundations of MS fencing posts - Mainfor foundations of MS fencing posts - Inclined support at every 30m
5631.20 m high welded steel wire fencing with 1.80 m RCC posts of standard design placed at every 3 m apart embedded in cement concrete blocks 45 x 45 x 60 cm of mix 1 : 5 : 10 (1 cement : 5 fine sand : 10 stone aggt. 40 mm nominal size), corner end and every 10th post to be strutted and embedded in cement concrete blocks of 70 x 45 x 50 cm of same mix provided with welded steel wire fabric 0.90 m wide, rectangular mesh 75 x 25 mm size weighing not less than 7.75 kg per Sq.m. fixed between the two posts fitted and fixed with GI staples on wooden plugs or tied to 6 mm bar nibs with binding wire including earth work in excavation, concrete work and cost of posts, struts etc complete.Area as per the Drawing - Longitudinal length x Height
564Add Carriage Charge
565Supply, Delivery, Installation Testing of Pumps Sets at Wet well 7KW-2Nos (1 Working 1 Standby)
566SUBMERSIBLE SEWAGE NON-CLOG VERTICAL PUMPSupply, delivery, installation, testing and commissioning of Submersible sewage, Non clog vertical type pump suitable for working on Air filled Dry type motor, three phase, 50 Hz +/-3%, 415V +/- 10%, AC supply, 1500 RPM synchronous speed with 3 core flat copper cable from pump to starter panel with cable end terminations (4) all supports, clamps, pipe fittings along with mechanical seal, bearing bush, strainer, arrangements for lifting for maintenance, guide pipes etc. complete set & following M.O.C: Casing CI, SS CF8M impeller, Bronze: wearing ring & Bearing bush, TC mechanical seal, CS/S.S. bearing, S.S shaft with sleeve, SS strainer & MS motor body, including compatible panel board consisting of Auto Transformer Starter suitable for local & remote pump control application consisting of Auto Transformer (vacuum impregnated, air cooled having three (3) tappings at 50%, 65% and 80%), incomer MCCB / MPCB, overload relay and contactors as per Type II coordination including digital MFM with RS 485 communication port, analogue type ammeter with selector switch, run hour meter, required protective relays & control accessories.STANDARD ACCESSORIESSupply, Delivery and Installation of Standard accessories including Power cable of PVC+Cu length 5mtrs, Pedestal auto rail coupling of Cast Iron(CI),Single Rail GR pipe of SS304 length 10Mtr and along with GRP coupler, Lifting chain with bow shackles and control panel including auto transformer starter Including Suction pipe dilavery pipe up to manifold sutuable Valves ,NRV,Pressure Gauge,Manifold etc. Total Head 17m
567Cost of Operational and Maintenance for 5 years Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 56694283
AUTHORITY Government Departments
TENDER VALUE Ref. Documents
LAST DATE 18-08-2026
Authority
Authority Name Urban Development And Housing Department
Work Description Tender for Design, Build, Construct And Commission Of 2 (Two) Sewage Treatment Plants Along With Co-Treatment Of Faecal Sludge / Septage With 5 Years Of Operation And Maintenance In Ziro Ulb Of Arunachal Pradesh
Basic Detail
Tender No EEUD/ZD/UWM-202/2024-25
Bidding Type Tender
Location
City Lower Subansiri
State Arunachal Pradesh
Key Dates
Publish Date 28 Jul 2026
Submission Date 18 Aug 2026
Open Date 18 Aug 2026
Finance
Tender Value Ref. Documents
Tender Fee 10000
EMD 25.44 Lakhs
Exemption Not Available
Document List
87c2cab7-c1bb-4981-8e12-40d8491e2a83.html
BOQ_3835.xls
SBD_STP_ZRO.pdf
Tendernotice_1.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Jul 28, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Aug 18, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 6 days
Aug 18, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 6 days

Tender Documents

Download All (ZIP) ↓
html

87c2cab7-c1bb-4981-8e12-40d8491e2a83.html

xls

BOQ_3835.xls

pdf

SBD_STP_ZRO.pdf

pdf

Tendernotice_1.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender