Public Administrative Department Government Departments Closing in 7 days TDR #56694153

Tender For Renovation Of Administrative Building And Auditorium Including Construction Of Shed For Bus, Ambulance And Implement Shed At Agriculture College Garhwa Under Bau, Kanke, Ranchi

Issued by Government Departments · Ranchi, Jharkhand
Tender Value
98.71 Lakhs
Estimated cost
Bid Submission
05 Aug 2026
7 days left
EMD
1.97 Lakhs
Bank guarantee accepted
Document Fee
10000
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Ranchi → Jharkhand
EMD Exemption
Not Available
Quantity
Not Available

Project Description

Tender for Renovation Of Administrative Building And Auditorium Including Construction Of Shed For Bus, Ambulance And Implement Shed At Agriculture College Garhwa Under Bau, Kanke, Ranchi

BOQ

Name of Work:- Renovation of Administrative building and Auditorium Including Construction of Shed for Bus, Ambulance and Implement Shed at Agriculture College Garhwa under BAU, Kanke, Ranchi
Sl. No. Item Description
1Extra for cleaning the old surface by scrapping the entire old white wash or colour wash including cost of scaffolding all complete as per direction of E/I
2Providing 12mm thick plaster (1:6) with clean coarse sand of FM 1.5 including screening curing with all leads and lifts of water scaffolding taxes and royalty all complete as per building specification and direction of E/I
3Providing 12mm thick water proof cement plaster (1:3) with clean coarse sand of F.M. 1.5 with 5% cico or any other approved water proofing compound including screening, curing with all leads and lifts of water, scaffolding taxes and royalty all complete as per building specification and direction of E/I
4Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete.
5Providing two coats of oil bound distemper of approved shade and make over a coat of cement primer over new surface including preparing the plastered surface by rubbing smooth with pumice stone or fine sand paper applying putty wherever required scaffolding washing of floors and taxes all complete as per building specification and direction of E/I
6Finishing walls with Premium Acrylic Smooth exterior paint with Silicone additives of required shade : New work (Two or more coats applied @ 1.43 ltr/ 10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/ 10 sqm)
7Providing two coats of synthetic enamel paint & Providing primer one coat of red lead paint approved shade and made over steel surface including cleaning the surface thoroughly, scaffolding and taxes all complete as per building specification and direction of E/I
8Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / paneling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of ineer-in-charge. (Glazing, paneling and dash fasteners to be paid for separately) :
9Providing and fixing 4 mm thick ACP Board in cub board as per direction of E/I.
10Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of engineer-in-charge. 4 mm th.
11Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of engineer-in-charge. 5.5 mm th.
12Supplying, fitting and fixing 40mm high vitreous white glazed earthenE.W.C. with ‘p’ trap of parry hindustan or any other approved I.S.S. make including supplying and fixing 15 litres C.I. mosquito proof low down flushing cistern of approved make with complete fittings with C.I.handle and R.S. or bracket with telescopic flush pipe with brass coupling and plumbers joints spindle stop cock of approved quality weight not less than 450grams 15mm P.V.C. alkathene pipe 45cm. long with brass coupling at both ends and white/black plastic solid state seal and lead of commander/cuckoo or other I.S.S. make with hinges or screws etc. painting pipe and cistern etc. with 2 coats of approved paint over a coat of red oxide priming, all complete as per specification and direction of E/I. 12.5 lit. low level PVC Cistem
13Supplying, fitting and fixing vitreous white glazed earthen ware I.W.C. of parry Hindustan or any other I.S.S.approved make with 100mm H.C.I. ‘p’ trap 15 litres C.I. pull and let go flushing cistern of names or other I.S.S.equivalent make, complete with all fittings,C.I. or C. C.brackets 32mm alkathene/P.V.C. telescopic flush, pipe about 2 Mlong with one brass coupling and clamps G.I. chain and pull including supplying and fixing a pair of vitreous white glazed earthenware ware footrest to be fixed in floor 15mm C.I. body brass spindle stope cock of weight not less than 50grms, 15mm P.V.C. connection pipe 450 mm. long and the exposed pipe a d cistern with two coats of approved paint over a coat of red oxide primer etc. all complete asper specification and direction of E/I. 580 mm long with 12.5 litre PVC low level cistern
14Supplying, fitting and fixing flat back or angular, lipped front vitreous white glazed earthen ware urinal of ‘Hindustan \\"Parry\\" or any other approved I.S.S make with 5 liters capacity C.I. automatic fulsing cistern of reliance for any other I.S.S. approved make with all fittings with C.I.or R.S. brackets, standard size G.I. flush pipe with fitting clamps,15mm C.I. body brass spindle stop cock of approved quality weight not less than 400grams, 15mm P.V.C./Alkthene pipe 450mm longwith brass coupling at both ends and doing plumber joints including painting of exposed part with two coats of approved paint overa priming coat of red oxide, cutting wall and floor, making good the same etc. all complete as per specification and direction of E/I. Flat back or standing corner (600mmx350mm)
15Providing and fixing P.V.C. low level flushing cistern with manually controlled device (handle lever) conforming to IS : 7231, with all fittings and fixtures complete. 10 litre capacity - White
16Providing and fixing 15 mm size CP brass pillar cock CI brass spindle pillar cock of approved quality as per specification and direction of E/I 15 mm dia
17Providing and fixing male ended 15mm dia brass bib cock of approved quality (Wt. not less than 350gm) with extra socket all complete as per specification and direction of E/I.
18Providing and fixing 15mm size C.P. brass stop cock (weight not less than 350gms) C.I. body brass spindle pillar cock of approved quality as per specification and direction of E/I. 15 mm dia
19Providing and fixing 15mm size C.P. brass stop cock (weight not less than 350gms) C.I. body brass spindle pillar cock of approved quality as per specification and direction of E/I.20 mm dia
20Providing and fixing 15mm size C.P. brass stop cock (weight not less than 350gms) C.I. body brass spindle pillar cock of approved quality as per specification and direction of E/I.25 mm dia
21Taking down chaukhats in windows including stacking serviceable materials within 15M lead and disposal of unserviceable materials with all leads all complete as per direction of E/I
22Providing coarse clean sand in filling in foundation trenches or in plinth including ramming and watering in layers not exceeding 150mm thick with all leads and lifts including cost of all materials, labour, royalty and taxes all complete as per building specification and direction of E/I. (Mode of measurement compacted volume).
23Filling in foundation trenches and plinth in layers not exceeding 150mm thick well watered, rammed, fully compacted and fine dressed with earth obtained after cutting within a lead of 50M and lift of 1.5M all complete as per building specification and direction of E/I
24Providing designation 75A one brick flat soling joints filled with local sand including cost of watering taxes royalty all complete as per building specification and direction of E/I.
25Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level :1:1½:3 (1 Cement: 1½ coarse sand (zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources
26Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion, (i) Single socketed pipes. 110 mm dia pipes
27Providing and fixing on wall face unplasticised - PVC moulded fittings/ accessories for unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS :5382, leaving 10 mm gap for thermal expansion. Coupler a) 100 mm dia
28Providing and fixing on wall face unplasticised - PVC moulded fittings/ accessories for unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS :5382, leaving 10 mm gap for thermal expansion. Shoes b) 100 mm dia.
29Providing and fixing on wall face unplasticised - PVC moulded fittings/ accessories for unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion. Bend c) 100 mm dia.
30Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete.
31Providing and fixing precoated galvanised iron profile sheets (size, shape and pitch of corrugation as approved by Engineer-in-charge) 0.50 mm (+ 0.05 %) total coated thickness with zinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns. Sheet should have protective guard film of 25 microns minimum to avoid scratches during transportation and should be supplied in single length upto 12 metre or as desired by Engineerin- charge. The sheet shall be fixed using self drilling /self tapping screws of size (5.5x 55 mm) with EPDM seal, complete upto any pitch in horizontal/ vertical or curved surfaces, excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required.
32Providing and fixing precoated galvanised steel sheet roofing accessories 0.50 mm (+0.05 %) total coated thickness, Zinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns using self drilling/ self tapping screws complete :
33Providing and fixing in position wall panelling at all heights with integral densified calcium silicate panels/tiles of size 595 x 595mm, having NRC (Noise Reduction coefficient) of 0.50 (minimum) as per IS 8225:1987, Light reflectance of 85% (minimum). Non combustibleas per BS:476 (part-4), fire performance as per BS:476 (part 6 &7),humidity resistance of 100%, thermal conductivity <0.043 W/m Kas per ASTM 518:1991, comprising of a frame made from especially fabricated galvanised mild steel sheet 0.50 mm thick pressed section (galvanizing @120 grams per sqm including both sides) i.e.vertical studs of size 48 x 34 x 36 mm are placed at 600mm center to centerin a floor and ceiling channel section of size 50 x 32m fixed to the floor and soffit at 600mm centers using 12mm dia,50mm long wedge type expanded zinc alloy dash fastner with 10mm bolt. This same channel is then to be fixed in horiziontal direction at 600mm center to center so as to form a grid of 600mm x 600mm. Glasswool of 50mm thickness is then to be inserted in the slots and finally calcium silicate non combustible panels/tiles are to be screw fixed with self tapping pan head nickel coated mild steel screws of size 13 x 3.2mm on to this grid leaving an even groove of 1 mm between the panels. The joints between the panels are to be duly jointed and finishedusing recommended jointing calcium silicate based compound and fiber joint tape roll 50mm wide (90 metre )roll and two coats of primer suitable for panelling as per manufacturer's specification as per direction of Engineer-in-Charge all complete.
34Providing & fixing pressed steel door frames manufactured from commercial mild steel sheet of 1.25mm thickness including hinges jamb,lock jamb,bead & if requried angle threshold of mild steel angle of section 50x25mm, or base tiles of 1.25mm pressed mild steel welded or rigidly fixed together by mechenical means, adjustable lugs withsplit endtail to each jamb including steel butt hingesto 2.5mm th. with mortar guards, lock strike plate & shock absorbs as specified & applying a coat of approved steel primer after pre treatment of the surface as directed by E/I.
35Supply, fitting & fixing 35 mm thick solid core type non decorative single leaf flush shutter in doors all complete as per direction of E/I
36Supply, fitting & fixing 35 mm thick solid core type non decorative double leaf flush shutter in doors all complete as per direction of E/I
37Providing and laying Ceramic glazed floor tiles of size 300x300 mm (thickness to be specified by the manufacturer) of 1st quality conforming to IS : 15622 of approved make in colours such as White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick cement mortar 1:4 (1 Cement : 4 Coarse sand), including pointing the joints with white cement and matching pigment etc, complete.
38Providing and laying 6mm precast white glazed tiles in walls over 12mm cement mortar (1:3) and jointed with grey cement slurry flush pointed with white cement including rubbing, polishing and cost of curing taxes and royalty all complete as per building specification and direction and of E/I
39Providing designation 75A brick work in C.M. (1:6) in foundation and plinth with approved quality of clean coarse sand of F.M. 2 to 2.5 including providing 10mm thick mortar joints, cost of screening materials, raking out joints to 15mm depth, curing, taxes and royalty all complete as per building specification and direction of E/I
40Providing designation 75A Brick work in C.M. (1:6) in super structure with approved quality of clean coarse sand of F.M. 2 to 2.5 including providing 10mm thick mortar joints, costs of screening, materials, scaffolding, raking out joints to 15mm depth curing, taxes and royalty all complete as per building specification and direction of E/I
41Providing and placing on terrace (at all floor levels) polyethylene water storage tank, ISI : 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank.
42Providing Tor steel reinforcement of 10mm, 12mm & 15mm dia bars as per approved design and drawing excluding carriage of M.S. Rods (straight or in coils) to work site, cutting, bending and binding with annealed wire with cost of wore, removal of rust, placing the rods in position all complete as per building specification and direction of E/I. 10 MM DIA
43Prov Tor steel reinforcement of 10mm, 12mm and 16mm dia bars as per approved design and drawing -do-do- (b) 12mm (TMT Coil Fe 500)(Only valid for Tata (Tiscon), SAIL, JSPL,Electrosteel steels,Bokaro and Vizag (RINL)) For 10mm Dia-
44Prov Tor steel reinforcement of 10mm, 12mm and 16mm dia bars as per approved design and drawing -do-do- (b) 12mm (TMT Coil Fe 500)(Only valid for Tata (Tiscon), SAIL, JSPL,Electrosteel steels,Bokaro and Vizag (RINL)) For 12mm Dia-
45Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement ,trenching ,refilling & testing of joints completeas per direction of Engineer in Charge. 20 mm dia pipes
46Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement ,trenching ,refilling & testing of joints complete as per direction of Engineer in Charge. 25 mm dia pipes
47Supply, fitting & fixing the following items complete with all materials as per specificaion and direction of E/I Mirror 600x450mm size
48Supply, fitting & fixing the following items complete with all materials as per specificaion and direction of E/I towel rail with bracket container
49c) C.P. brass soap dish container medium quality with screw and hinges etc
50Supplying fitting and fixing vitreous white glazed earthen ware wash hand basin of parry or Hindustan or any other I.S.S. approved make supported on painted C.I. or R.S. brackets 32mm C.I.brass waste, 15mm dia C.I. body brass spindle stop cock of approved quality of weight not less than 350grams, 32mm P.V.C. waste pipe 750mm long with brass coupling at one end and making plumber joints etc. all complete as per specification and direction of E/I. size 630x450 mm
51Providing and laying Doublecharge vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS: 15622 / ISO 13006 of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqm including grouting the joints with white cement and matching pigments etc., complete. Size of Tile 600x600 mm .
52Providing and fixing aluminium die cast body tubular type universal hydraulic door closer (having brand logo with ISI, IS : 3564, embossed on the body, door weight upto 35 kg and door width upto 700 mm), with necessary accessories and screws etc. complete.
53Providing and fixing mineral fibre false ceiling tiles at all heights of size 595X595mm of approved texture, design and pattern. The tiles should have Humidity Resistance (RH) of 99%, Light Reflectance ? 85%, Thermal Conductivity k = 0.052 - 0.057 w/m K, Fire Performance as per (BS 476 pt - 6 &7)in true horizontal level suspended on interlockingT-Grid of hot dipped all round galvanized iron section of 0.33 mm thick (galvanized @120 gsm) comprising of main T runners of 15x32 mm of length 3000 mm, cross T of size 15x32mm of length 1200 mm and secondary intermediate cross T of size 15x32 mm of length 600 mm to form grid module of size 600x600 mm suspended from ceiling usinggalvanized mild steel item (galvanised@80gsm) 50 mm long 8mm outer diameter M-6 dash fasteners, 6 mm diameter fully threaded hanger rod up to 1000 mm length and L-shape level adjuster of size 85x25x2 mm, spaced at 1200 mm centre to centre along main ‘T’. The system should rest on periphery walls /partitions with the help of GI perimeter wall angle of size24x24X3000 mm made of 0.40 mmthick sheet, to be fixed to the wall with help of plastic rawl plug at 450 mm centre to centre & 40 mm long dry wall S.S. screws. The exposed bottom portion of all T-sections used in false ceiling support system shall be pre-painted with polyester baked paint, for all heights. Thework shall be carried out as per specifications, drawings and as perdirections of the engineer-in-charge.
54Dismantling old plaster and pointing in cement or lime and raking out joints to 15mm depth watering and disposal of unserviceable materials with all leads all complete as per direction of E/I
55Dismantling plain cement or lime concrete work including stacking serviceable materials in countable stacks within 15M. Lead and disposal of unserviceable materials with all leads all complete as per direction of E/I.
56Dismantling tile work in floors and roofs laid in cement mortar including stacking material within 50 metres lead. For thickness of tiles 10 mm to 25 mm
57Dismantling R.C.C. work including stacking serviceable materials in countable stacks within 15M. Lead and disposal of unserviceable materials with all leads all complete as per direction of E/I.
58Dismantling pucca brick or lime work including stacking serviceable materials in countable stacks within 15M lead and disposal of unserviceable materials with all leads all complete as per direction of E/I.
59Providing & Applying high quality acrylic modified resin based texture of Dholpur/Red sand stone Pattern with anti algae and UV resistance properties to be applied as intermediate finish in desired pattern @ 43.04 kgs/10 sqm to form film of 1- 1.5 mm thickness after scrapping and properly cleaning the surface to remove loose particles from the plaster surface, followed by top coating with Premium Acrylic Smooth exterior paint with Silicone additives of required shade by two or more coats @ 1.43 litres/10 sqm, complete as the direction of Engineer -in-Charge
60Providing two coats of synthetic enamel paint of approved shade and make over old wooden surface including preparing the surface after cleaning, removing dirt, scales, smokes, grease and sand papering, including cost of scaffolding and taxes all complete as per building specification and direction of E/I
61Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion, (i) Single socketed pipes. 110 mm dia pipes
62Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement ,trenching ,refilling & testing of joints complete as per direction of Engineer in Charge. 25 mm dia pipes
63Water proofing for Old and New Roof Slab :- Providing and laying water proofing treatment on roof slab by applying two Component, factory designed, ready to use, acrylic modified flexible
64Earthwork in excavation in foundation trenches in ordinary soil (vide classification of soil item-A) and disposal of excavated earth as obtained to a distance upto 50 M. including all lifts, levelling. ramming the foundation trenches, removing roots of trees, shrubs all complete as per approved design, building specification and direction of E/I.
65Providing designation 75A one brick flat soling joints filled with local sand including cost of watering taxes royalty all complete as per building specification and direction of E/I
66Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering-All work up to plint level:1:2:4 (1 Cement : 2 Coarse sand (Zone-III) : 4 graded stone aggregate 20mm nominal size)
67Providing and laying in position specified grade of reinforced cement concrete excluding the cost of centering, shuttering, finishing and reinforcement-all work up to plinth level. 1:1.5:3 (1 Cement: 1.5 Coarse sand (Zone-III) : 3 graded stone aggregate)
68Centering and shuttering including strutting, propping etc and removal of form for Foundations, Footings, bases of columns etc for mass concrete
69Reinforced cement concrete work in walls (any thickness) including attached plasters buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc above plinth level upto floor five level excluding cost of centering, shuttering, finishing and reinforcement 1:1.5:3 (1 Cement: 1.5 Coarse sand (Zone-III) : 3 graded stone aggregate) 20mm nominal size
70Centering and shuttering including strutting, propping etc and removal of form for columns, pillars, piers,abutments, posts and struts
71Painting G.I. pipes and fittings with synthetic enamel white paint with two coats over a ready mixed priming coat, both of approved quality for new work
72Making plinth protection 50mm thick of cement concrete 1:3:6 (1 cement : 3 coarse sand (zone-III) derived from natural sources : 6 graded stone aggregate 20 mm nominal size derived from natural sources) over 75mmthick bed of dry brick ballast 40 mm nominal size, well rammed and consolidated and grouted with fine sand, including necessary excavation, levelling & dressing & finishing the top smooth.
73Extra for providing and fixing 30x4mm glass strips in joints of flooring complete job as epr specifications and direction of E/I
74Wiring for light point/fan point/ Exhaust fan point with 1.5 sq. mm FR PVC insulated copper conductor single core cable in surface/recessed PVC conduit, with modular switch, modular plate , suitable GI box etc. as required. Group C
75Wiring for circuit/submain wiring along with earthwire with the following sizes of PVC insulated copper conductor single core cable in surface/recessed PVC conduit as required. 2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire
76Wiring for circuit/submain wiring along with earthwire with the following sizes of PVC insulated copper conductor single core cable in surface/recessed PVC conduit as required. 2 X 4.0 sq.mm + 1 X 4.0 sq.mm earth wire(for A.c)
77Wiring for light/power plug with 2x4.0 sq.mm FR PVC insulated copper conductor single core cable in surface/recessed PVC conduit along with 1 no 4 sq.mm FR PVC insulated copper conductor single core cable for loop earthing etc as required.
78Supplying & fixing of following modular type switch/socket on the existing modular plate and switchbox including connection etc as required 15/16 amps ,one way switch
79Supplying & fixing of following modular type switch/socket on the existing modular plate and switchbox including connection etc as required 15/16 amps 6 pin socket outlet
80Supplying and fixing following size/module ,GI box along with modular base & cover plate for modular switches in recess etc as required. 6 modules (78mmx230mmx60mm)
81Supplying, fitting and fixing of following way horizontal type three pole and neutral sheet steel MCB distribution board 415 volt on surface/recess complete with tinned copper busbar ,neutral bar powder painted including connection etc as required(but without MCB). 4 way (4+12)Double door, Vertical
82Supplying and fixing of 6 amps to 32 amps rating ,240 volts,10KA “C” curve miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connection , testing and commissioning etc as required 6/32 amps, Single Pole
83Supplying and fixing of 6 amps to 32 amps rating ,240 volts,10KA “C” curve miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connection , testing and commissioning etc as required 63 amps, TPN
84Supplying and fixing of 20 amps 240volt ,SPN industrial type socket outlet with 2 pole and earth metal enclosed plug top along with 20 amps C curve SP MCB in sheet sreel enclosure on surface or in recess with chained metal cover for socket outlet and complete with connection etc as required.
85S.I.T.C of following rating surface mounted LED tube light complete with connection as required. Make- Bajaj/jaguar/ C&S or equivalent 20/22 watt LED Tube light
86Supplying following sizes and core PVC/XLPE insulated PVC sheated ,heavy duty , unarmoured electric cable with copper conductor for working voltage upto and including 1100 volt. Make –Havells/ Polycab or equivalent. 25 sq.mm, 3.5 core copper cable unarmoured
87S.I.T.C of following rating recess/surface mounted LED Down light luminaries with pressure die cast housing for single phase supply voltage as required. 2’x2’ LED Panel Light
88Supply and fixing of 450mm (18’’)metal body wall fan with speed regulator suitable for single phase 220 V,50Hz AC Supply.
89Earthing with copper earth plate 600mmX600mmX3mm thick including accessories and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc (with charcoal or coke and salt) as required.
90Providing and fixing 4.00mm dia copper wire on surface or in recess for loop earthing etc as required.
91a) Sand lead 30 Km
92b) Stone chips lead 30 KM
93C)Brick (8 Km)
94Add GST @ 18%
95Add LWF @1 % Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 56694153
AUTHORITY Government Departments
TENDER VALUE 98.71 Lakhs
LAST DATE 05-08-2026
Authority
Authority Name Birsa Agricultural University
Work Description Tender for Renovation Of Administrative Building And Auditorium Including Construction Of Shed For Bus, Ambulance And Implement Shed At Agriculture College Garhwa Under Bau, Kanke, Ranchi
Basic Detail
Tender No 245 Dated 22.07.2026
Bidding Type Tender
Location
City Ranchi
State Jharkhand
Key Dates
Publish Date 28 Jul 2026
Submission Date 05 Aug 2026
Open Date 06 Aug 2026
Finance
Tender Value 98.71 Lakhs
Tender Fee 10000
EMD 1.97 Lakhs
Exemption Not Available
Document List
7f18d8a2-878c-4568-bf70-7fdcd15ddc0a.html
BOQ_157600.xls
Tendernotice_1 (17).pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Jul 28, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Aug 05, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 7 days
Aug 06, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 8 days

Tender Documents

Download All (ZIP) ↓
html

7f18d8a2-878c-4568-bf70-7fdcd15ddc0a.html

xls

BOQ_157600.xls

pdf

Tendernotice_1 (17).pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail
Loading tenders