Drinking Water Supply and Sanitation Government Departments Closing in 16 days TDR #56692301

Tender For Laying Pipeline For Flood Mitigation And Recharge At Village Salasar Ps Sujangarh District Churu

Issued by Government Departments · Sikar, Rajasthan
Tender Value
2.90 Crore
Estimated cost
Bid Submission
18 Aug 2026
16 days left
EMD
5.81 Lakhs
Bank guarantee accepted
Document Fee
5000
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Sikar → Rajasthan
EMD Exemption
Available
Quantity
Not Available

Project Description

Tender for Laying Pipeline For Flood Mitigation And Recharge At Village Salasar Ps Sujangarh District Churu

BOQ

Name of Work:- Laying Pipeline for Flood Mitigation and Recharge at Village Salasar PS Sujangarh District Churu
Sl. No. Item Description
11.1 Providing, lowering, laying in trenches, aligning, fixing in position and jointing Ductile Iron (DI) ISI marked K-7 grade S&S pipes as per IS:8329-2000 (amended up to date), with internal cement mortar lining suitable for potable water with rubber ring (EPDM) joints as per IS: 5382-1985 including all taxes (Central and local), transportation and freight charges, inspection charges, loading/ unloading charges, including cost of labour and material, specials (Tee, bend etc.) satisfactory hydraulic testing, disinfection, commissioning etc. complete as per technical specifications and direction of Engineer-in-charge. (excluding earth work) Note : Providing and fixing of all requisite specials as per drawing, design and layout are inclusive in RM measurement of the item and shall not be paid separately.1.1.11 600 mm
2Dismantling cement concrete including disposal of material within 50 m lead, inclusive of de-watering wherever required.
3Cutting & clearance of jungle, bushes, shrubs Ankra/Ipomoea, Juliflora typna etc. on canal and bunds in dry/moist/slushy conditions including disposal as per instructions of the Engineer-in-charge. Cost of wood has been deducted from rates and thus will be property of contractor after cutting. Thick
4Hand broken stone aggregate of various sizes in accordance with IS:383 1970 for concrete work for dams, canals, and other important structures, well graded with size of aggregate including all lead and lift. 150 to 80 mm size
5Hand broken stone aggregate of various sizes in accordance with IS:383 1970 for concrete work for dams, canals, and other important structures, well graded with size of aggregate including all lead and lift. 80 to 40 mm ( Hand broken)
64.11 Supply laying and pushing of MS casing pipe of specified thickness approved by concerned department authority by trenchless method adopting any suitable technology below ground at required depth under running traffic condition as per Highway/ Railway standard including carrying out survey work at the job site for determining underground cable trenches like telephone, cable, water & sanitary lines and resistivity test for finding the soil strata using necessary equipments for completion of works, mobilizing of machineries and specialized crew at the job site complete in all respect, including excavation of driven pit and exit pit (up to 3 meter depth) with proper protection at these sites with shoring sheets and ISMB. Providing MS cutting edges for front shield and constructing thrust bed at designated level. Necessary dewatering and providing concrete foundation at the base of the driven pit, PVC/Rubber saddle as per the requirement of Highway/Railway authority, crane for handing of pipe and any other machinery, tools, and tackles required, construction of temporary works as per design, drawing and method as per approved by authority specification and the direction of the Engineer.Apply corrosion, resistant, protection on inside and outside of casing pipe as per technical specification. 4.11.5 700 mm Dia 10 mm thick casing pipe .
7Excavation including loading, unloading, disposal and dressing of excavated earth within initial lead of 50m and lift up to 1.5m including dressing of excavated area and dewatering wherever required complete in all respect Soft/Loose soil
8Earth work in excavation in foundation, trenches etc. including dressing of sides and ramming of bottoms, including getting out the excavated material, refilling after laying pipe/ foundation and disposal of surplus excavated material at a lead upto 50m suitable site as per direction of Engineer for following depths, below natural ground / Road top level. In all types soils/ saturated soil such as morrum, sand, sandy silt, clay, black cotton soil, kankar, etc.Depth upto 1.5 m
95.8 Providing and fixing at site with necessary packing, Horizontal Centrifugal Split Casting pumps with 4 pole induction motor operating at syncronised speed of speed 1500 RPM as per IS 12615: 2011 or amended up to date , CI casing and casing ring, SS 316 impeller, SS 410 Shaft and shaft sleeve, coupling guard, common base plate, foundation bolts, Cement concrete foundation etc. complete with all respect as per the specification and scope of work and direction of Engineer in Charge of following range of duty conditions.Note: Duty condition of required pump shall also be mentioned in BoQ. 5.8.1 Discharge 201 to 220 LPS and head 20 to 30 M
106.18 Providing, lowering, laying, aligning, fixing in position and jointing MS dismantling joint (Fabricated Steel) as per IS specifications complete of the following sizes including all jointing material, cost of all labour, testing and commissioning Technical Specifications and as per direction of Engineer. 6.18.12 600 mm dia
116.3 Providing, lowering, aligning, fixing in position in pipe line, CI double flanged swing type Non Return Valves (NRV) of approved make of following Pressure rating & dia complete, confirming to IS: 5312 (part -1)/ 2004 (amended up to date) and of following specifications: Body, Cover & disc of Grey cast iron of IS:210/ FG200. Face to face dimensions as per IS 5312 (part -1):2004 , Flanges Drilled as per IS:1538. Epoxy (Non-Toxic & suitable for drinking water) applied on body, cover and disc inside and outside . Body seat ring of SS/CS Door face ring - EPDM/ Neoprene (food grade quality) ,Shaft of HTB1/ SS- AISI- 410 ,Hinge Maleable cast iron / SS AISI 316/410 ,Bonnet Gasket EPDM, Bush- Leaded tin Bronze/ PTET, Gasket EPDM/NBR ,Nut-Bolt as per IS:1363 and IS: 1367 (galvenised steel) ,Insersion rubber of black EPDM 6mm thick. Suitable support structure as per directions of EICincluding jointing & jointing material, labour, testing and commissioning along with pipeline as per Technical Specification & as per direction of Engineer-in-charge. Note: Rates are exclusive of tail piece/ dismantling joints and earth work.of approved make (IS: 5312 amended upto date) of following Class and dia complete including all material, labour, testing and commissioning along with pipe line as per Technical Specifications and as per direction of Engineer-in-charge.Note: Rates are exclusive of tail piece/ dismantling joints and earth work. 6.3.1 Class PN 1.06.3.1.12 600 mm dia
126.7 Providing, lowering, aligning, fixing in position and Jointing in pipe line, CI Body Flanged End Tamper proof Kinetic Air Valve of approved makes of following pressure rating and dia and as per following specifications: Governing standard - AWWA C512/ IS:14845:2000(ammended up to date),Body, High pressure cover , Low pressure cover, Cowl and Joint support ring - Grey cast iron of grade IS:210/FG200 ,Float- LP ball & HP ball : AISI 304 stainless Steel, Float Guide- HTB1,Seat ring & Gasket - EPDM/NBR, HP Orifice & HP orifice plug : HTB2/ SS ,Bush: Bronze , Flanges as per IS/ BS, Drilled as per IS:1538. Epoxy paint (Non-Toxic & suitable for drinking water) applied on body & cover inside and outside Fastners - CS/ Galvenised steel ,Outlet of big orifice will have a screen to prevent Tamper of float, with CI metal seated D/F Non rising stem Sluice Valves as per (IS: 14846 amended upto date) PN 1.0 ratings Valves including all mateial, labour, testing and commissioning as per Technical Specifications and as per direction of Engineer in charge.Note: Rates are exclusive of connecting tee, pipe piece and earth work. 6.7.1 Class PN 1.06.7.1.3 80 mm
136.8 Providing, lowering, aligning, fixing in position in pipe line at work site, DI D/F Resilient seated (soft seated) Sluice Valves (Gate Valves) , Vacuum tight(bubble tight), straight and pocket less body passage of approved make of following class & dia complete confirfing to BS-EN-1171/ AWWA C-509 and of following specifications: Body & bonnet of Ductile cast iron of grade GGG40/GGG50 as per DIN 1693 or GR SG-400/12 as per IS 1865 or equivalent grade as per IS :3896-part2-1985 and subsequent revisions, Wedge of same material as body & shall vulcanised rubber lined with EPDM (food grade quality) and seals of NBR Face to face dimensions as per BS 5163-89/ IS 14846/2000 (amended up to date) /Din 3202 F4, Stem/ spindle of SS AISI 316/ 410 Electrostatic epoxy powder(EP-P)/ Fusion bond epoxy ( Non-Toxic- suitable for drinking water) coated with minimum thickness of 250 microns inside and outside, Drilled as per IS 1538. Nut-Bolt confirming to IS:1363 and IS: 1367 (Galvanised steel) Insersion rubber of black EPDM 6mm thick. Suitable support structure as per directions of EIC, Sluice valves including all jointing & jointing material, labour, testing and commissioning along with pipe line as per Technical Specifications and as per direction of Engineer-in-charge. Note: Rates are exclusive of tail piece/ dismantling joints and earth work. 6.8.2 Motorized Sluice Valves with Electric Actuator and integral starter of Class PN 1.06.8.2.12 600 mm dia
148.1 Construction of Pump house of brick/ stone masonry of required size suitable for installation of maximum 4 no. Monoblock pump sets as per approved GA drawing, scope of work and technical specification complete work in all respect including electrical works for lighting and fans, rain water drainage. The plinth area of pump house shall be area of measurement.
159.1 Construction of RCC Sluice valve chamber for different type of valves including earthwork excavation, 100mm PCC M15 as leveling course, RCC M25 grade for base slab, side wall & cover slab , including cost of steel reinforcement , form work, Pre-cast, Plastic encapsulated CI/MS Foot Rest, MS flats for the support of pre-cast, proper curing of concrete work complete in all respect as per specifications and standard drawings and as directed by Engineer-in-Charge.9.1.1 For Class-AA loading9.1.1.5 Sluice valve chamber of size 1.61m x1.75m x2.85m for pipe size-from 500-to-700mm
169.2 Construction of RCC Air valve chamber for different type of valves including earthwork excavation, 100mm PCC M15 as leveling course, RCC M25 grade for base slab, side wall & cover slab , including cost of steel reinforcement , form work, Pre-cast, Plastic encapsulated CI/MS Foot Rest, MS flats for the support of pre-cast, proper curing of concrete work complete in all respect as per specifications and standard drawings and as directed by Engineer-in-Charge.9.2.1 For Class-AA loading9.2.1.1 Air valve chamber of size0.9m x1m x1.695m for air valve size-from 50 mm-to-80mm
17Providing and Laying in position of Cement concrete Design mix M-20 including leads of all construction materials, plasticizers (if required), curing, compaction and finishing with rendering in cement sand mortar 1:3 ( 1 cement : 3 coarse sand) and making good the joints excluding the cost of centering, shuttering and reinforcement. Well graded crusher broken stone aggregate of maximum size upto;(For mix design Cement content considered 400 kg/ cum of concrete) 20 mm
18Providing and Laying in position of Cement concrete Nominal mix (1:1.5:3) including leads of all construction materials, curing, compaction and finishing with rendering in cement sand mortar 1:3 (1 cement : 3 coarse sand) and making good the joints excluding the cost of centering, shuttering and reinforcement. Well graded crusher broken stone aggregate of maximum size upto; 20 mm Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 56692301
AUTHORITY Government Departments
TENDER VALUE 2.90 Crore
LAST DATE 18-08-2026
Authority
Authority Name Water Resources Department
Work Description Tender for Laying Pipeline For Flood Mitigation And Recharge At Village Salasar Ps Sujangarh District Churu
Basic Detail
Tender No SE NIT 02/2026-27_Salasar
Bidding Type Tender
Location
City Sikar
State Rajasthan
Key Dates
Publish Date 28 Jul 2026
Submission Date 18 Aug 2026
Open Date 19 Aug 2026
Finance
Tender Value 2.90 Crore
Tender Fee 5000
EMD 5.81 Lakhs
Exemption Available
Document List
44b4ca1f-ab7b-45bb-90a9-01a9ad737f62.html
BOQ_1027859.xls
FloodMitigation.pdf
Tendernotice_1.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Jul 28, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Aug 18, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 16 days
Aug 19, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 17 days

Tender Documents

Download All (ZIP) ↓
html

44b4ca1f-ab7b-45bb-90a9-01a9ad737f62.html

xls

BOQ_1027859.xls

pdf

FloodMitigation.pdf

pdf

Tendernotice_1.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail
Loading tenders