Tender For Repair/Replacement /Cleaning Of Sewage Line, Manholes ,Septic Tank, Wc Pan , Gully Traps, Soak Pits At X Area Etc At Afs Amla
Tender Value
15 Lakhs
Estimated cost
Bid Submission
18 Aug 2026
15 days left
EMD
30000
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Betul → Madhya Pradesh
EMD Exemption
Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender for Repair/Replacement /Cleaning Of Sewage Line, Manholes ,Septic Tank, Wc Pan , Gully Traps, Soak Pits At X Area Etc At Afs Amla
BOQ
| Sl. No. | Item Description |
| 1 | Demolition of cement concrete (unreinforced) in ground floors and pavings not exc 15cm thick (below or above ground level) complete all as specified and as directed. |
| 2 | M&L for PCC 1:3:6 type C-2 (using 40 mm graded stone aggregate) as in foundation and mass concrete complete all as specified and directed. |
| 3 | M&L for PCC 1:2:4 type B-1 (using 20 mm graded stone aggregate) as in benching and finishing the surfaces even and smooth using extra cement complete all as specified and directed. |
| 4 | Demolition of brick work built in cement mortar (manhole soak well & septic tank etc.) including coping complete all as specified and as directed. |
| 5 | M&L for birck work with fly ash brick 75 kg/cmsq compressive strength. Modular size , is straight or curved on pian exc. 6 metre mean radius built in cement mortar 1:6 complete all as specified and directed. |
| 6 | Demolition and Breaking up drain pipes of internal dia 150mm including PCC haunching, benching and bed concrete complete all as specified and directed. |
| 7 | Demolition and Breaking up drain pipes of internal dia 200mm including PCC haunching benching and bed concrete complete all as specified and directed. |
| 8 | M&L for 150 mm dia Reinforced cement concrete pipes, Class NP-2, laid in trenched and jointed with collar, complete all as specified and directed. |
| 9 | M&L for 200 mm dia Reinforced cement concrete pipes, Class NP-2, laid in trenched and jointed with collar, complete all as specified and directed. |
| 10 | M&L for PCC 1:3:6 type C2 (using 40 mm graded stone aggregate), as in bed to drain pipes including packing under and haunching against sides of pipes for 150 mm bore after they are laid and tested complete all as specified and directed. |
| 11 | M&L for PCC 1:3:6 type C2 (using 40mm graded stone aggregate), as in bed to drain pipes including packing under and haunching against sides of pipes for 200 mm bore after they are laid and tested complete all as directed. |
| 12 | M&L for extra for forming fair finished drain or channels 30cm inner girth cement concrete using extra cement including forms, moulds, mitred / stopped ends etc complete all as specified and directed.Note :- Inner girth only will be measured and paid. |
| 13 | Demolition of plain cement concrete of any description and in any position not otherwise specifically provided for complete all as specified and as directed. |
| 14 | M&L for PCC 1:2:4 type B-1, (using 20mm graded stone agreaget) as in coping, hold fast and the like including weathering slightly rounded or chamfered angles and throting as directed with necessary formwork and finishing expsoed faces of concrete complete all as specified and directed. |
| 15 | M&L for 10 mm thick rendering in cement mortar 1:4 on fair faces of brick work finished even and smooth without using extra cement complete all as specified and directed. |
| 16 | M&L for 15mm thick rendering in cement mortar 1:6, on fair faces of brick work finished even and fair complete all as specified and directed. |
| 17 | Excavation in trenches n.exc 1.5 metre wide and n.exc 1.5 metre in depth for foundations etc, or for shafts, wells, mahnoles etc. not exc. 10 Sqm on plan and n.exc 1.5 metre in depth and getting out in soft/loose soil in foul condition complete all as specified and directed. |
| 18 | All as per item 17 above but for depth exceeding 1.5 metre and not exceeding 3 metre and getting out in soft/loose soil in foul condition complete all as specified and directed. |
| 19 | Returnning, filling in, including spreading, levelling, watering and well rammaing in layers not exceeding 25 cms thick in layers in slft/loose soil complete all as specdified and directed. |
| 20 | Removing excavated material exc 50m but not exc 250m deposited/spreaded where as in soil or material complete all as specified and as directed |
| 21 | Demolition of reinforced cement concrete (ie manhole cover) in ground floors exc 15 cm thick (below or above ground leave) reinforcement cut as required to facilitate demolition complete all as specified and as directed. |
| 22 | M&L for provididng precast reinforced cement concrete 1:2:4 ytpe B-1 (using 20mm graded stone aggregate) as in landings, cover slabs (for man hloes etc,) chullah noods, chajjas set in cement mortar 1:4 incuding necessary form work compete all as specified and directed. |
| 23 | M&L for mild steel TMT bars, 10mm dia and over, cut to length bent to shape required, including cranking bending spirally or hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9 mm dia or securing with clips, complete all as specifid and directed. |
| 24 | M&L for handles, rungs, brackets etc. and mimilar articals made out of mild steel round bars 10mm dia and over bent to shape required complete all as specified and directed. |
| 25 | Taking down CI/AC/PVC pipes jointed in cement mortar etc and taking from eaves gutters, and rainwater pipes from walls (any size or pattern), including all fittings, heads, shoes, bends, swan-necks, etc., including cleaning or refixing or removal to Store (measured overall as fixed along the centre line over fittings and accessories) including all type of bends/branch pieces complete all as specified and as directed. |
| 26 | S & F 75mm bore PVC (SWR) pipes single socketed, in any length with rubber ring joints, laid in trenches or in floors complete all as specified and as directed. |
| 27 | S & F 110mm bore PVC (SWR) pipes single socketed, in any length with rubber ring joints, laid in trenches or in floors complete all as specified and as directed. |
| 28 | S & F 75mm bore PVC (SWR) pipes single socketed, in any length with rubber ring joints, fixed in wall complete all as specified and as directed. |
| 29 | S & F 110mm bore PVC (SWR) pipes single socketed, in any length with rubber ring joints, fixed in wall complete all as specified and as directed. |
| 30 | S & F in repairs 75mm bore PVC (SWR) bends of any radius complete all as specified and as directed. |
| 31 | S & F in repairs 110mm bore PVC (SWR) bends of any radius complete all as specified and as directed. |
| 32 | S & F in repairs 75mm bore PVC (SWR) branch piece, single (double Y) equal or unequal bends of any radius, fixed with cement solvent, with oval access door complete all as specified and as directed. |
| 33 | S & F in repairs 110mm bore PVC (SWR) branch piece, single (double Y) equal or unequal bends of any radius, fixed with cement solvent, with oval access door complete all as specified and as directed. |
| 34 | S & F in repairs 75mm bore PVC (SWR) junction single (single T) equal or unequal bends of any radius, fixed with cement solvent, with oval access door complete all as specified and as directed. |
| 35 | S & F in repairs 110mm bore PVC (SWR) junction single (single T) equal or unequal bends of any radius, fixed with cement solvent, with oval access door complete all as specified and as directed. |
| 36 | S & F in repairs 110mm bore PVC (SWR) vent cowl including taking down old unserviceable vent cowl complete all as specified and as directed. |
| 37 | S & F in repair 75mm dia PVC (SWR) nahani trap, plain with grating including jointing fixed with solvent cement to waste pipe complete all as specified and as directed. |
| 38 | S&F in repairs vitreous China squatting pan, ‘Orissa’ pattern, size 580 x 440 mm white, with integral foot rests (excluding flushing cistern and flush pipe) including connection to trap and to flushing pipe anti syphonape pipe etc complete including making good to floor complete all as specified and directed. |
| 39 | S&F in repair vitreous china wash down water closet pan (Pedestal pattern), white (excluding fixing bolt, flushing cistern and flush pipe) but including seat cover of white colour complete all as specified and as directed. |
| 40 | S&F in repair PVC (SWR) 'P' trap bore 110mm/100mm complete all as specified and as directed. |
| 41 | S&F in repair PVC (SWR) 'S' trap bore 110mm/100mm complete all as specified and as directed. |
| 42 | Dismantling floor, hearth or wall tiling in cladding cement mortar bedding (but not backing) removing serviceable tiles to store and rubbish off the premises complete all as specified and directed. |
| 43 | M&L for glazed ceramic colour tiles 350 x 250 x 7 mm/ 450 x 300 x 7mm thick in skirting/dados etc set and jointed in neat cement slurry and pointed in white or coloured cement to match the colour tiles over and including 10mm thick rendering in CM(1:4) complete all as specified and as directed. |
| 44 | M&L for non skid colour ceramic tiles 300x300x7 mm thick, in floors etc set and jointed in neat cement slurry and pointed with white or coloured cement to match and laid over 15 mm thick screed bed (1:4) etc complete all as specified and as directed. |
| 45 | Taking down GI/CPVC/UPVC tubing 15/16mm bore complete all as specified and directed |
| 46 | Supply and fix GI tubing 15mm bore medium grade with all fittings fixed to wall and ceiling complete all as specified and directed. |
| 47 | M & L for cutting out any type of vegetation complete from root grouted inside the wall specially in contact with sanitary pipe and pouring/grounting with hydrochloric acid (HCL) on left out rout if any including making good surfaces to match adjacent surfaces in PCC (1:2:4) type B-0 or 15mm thick plaster in CM (1:4) complete all as specified and as directed. |
| 48 | Tools & Labour for taking out/dewatering of sewage water/ muddy water/ sludge/ mud/ silt or any other dirty & filthy material at bottom in foul condition from the manholes of any size and any depth by using sewage pump/ mechanically or manually by using buckets/ baskets, lifting the same of any capacity & any depth from GL and removing the ejected/ obtained material to a distance not exceeding 50 mtr, filling the sludge in newly excavated pit, treating with bleaching powder and refilling top of pit with earth & removing balance earth to a distance n. exc 50 mtr including taking down precast covers and fixing of the same with CM (1:4) after cleaning without damaging complete all as specified and directed.Note : Rate quoted shall deemed to be included cost of all excavation & earth work. |
| 49 | Tools & Labour for Cleaning of sewage pipe lines of any bore and removing the blockages by rodding using bamboo and gunny bags or by manually, between the manholes, Nahani traps to gully traps, gully traps to manholes including vertical stack pipes (where ordered), cleaning eye to gully trap and taking out all debris, sludge or any solid/foreign materials from sewage line and flushing with water and testing after cleaning; including removing the debris outside MoD land in closed container complete all as specified and directed. |
| 50 | Tools & Labour for Cleaning of sewage sump wells, septic tanks of any dia/depth and in any location etc. by taking out complete sludge, water and solids of any type by mechanically HCV (Heavy Commercial Vehicle) mounted suction discharge machine/sewage sucker tanker having blow back facility with sludge tank of capacity not less than 6000 ltr (fully covered) removing and disposing the entire retrieved material outside the periphery of defence land taking precautionary measure incl, required tools and plant complete working in foul condition and vocering the entire sludge and solids with local earth complete all as specified and directed. Note : Rate quoted for above item shall be deemed to included in the cost of adequate T&P, equipment, safety devices etc alongwith sufficient labourers to full fill the requirement to the entire satisfaction of Engineer-in-Charge no extra payment will not to be entertain by Govt. |
| 51 | Tools & Labour for Cleaning of septic tank manually or mechanically by bailing out sewage and night soil/sludge etc. and removing the silt/sludges to a distance exceeding 50m but not exceeding 100 m from the septic tank and depositing in burying pit; including taking out manhole covers (RCC/CI) and refixing the same in position of any size complete all as specified and directed. Note: Excavation work for burying pit shall be measured and paid separately. |
| 52 | Tools & Labour for cleaning of water closet (IWC/EWC) in foul condition upto 1st manhole from first floor/ground floor as the case may be by rodding and removing the debris including cutting of small vegetation where ever found at site complete as directed. |
| 53 | Tools & Labour for cleaning of Gully trap/ Nahani trap/ Floor trap in foul condition upto 1st manhole from first floor/ground floor as the case may be by rodding and removing the debris including cutting of small vegetation where ever found at site complete as directed.Notes : For Ser No 52 & 53 :-(a) Contractor/Rep of the contractor has to collect the complaints offline/online on daily basis from incharge of complaint cell.(b) The blockage of WC/Floor Trap/Gully trap are to be cleared on the same day of the receipt of complaint.(c) In case of non attaedence of complaints of WC blockage/Gully/Floor traps by the contractor on the same day, a penalty of Rs. 500/-per complaints per day will be recovered from the contractor. |
| 54 | Material and labour for providing water proofing tratment of sunken portion of WC, bathroom etc (not excceeding 45 Cm depth of sunken) as specified below complete all as specified and directed. Please Enable Macros to View BoQ information |
| 55 | Material and labour for providing water proofing tratment of sunken portion of WC, bathroom etc (not excceeding 45 Cm depth of sunken) as specified below complete all as specified and directed. Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Jul 28, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedAug 18, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 15 daysAug 20, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 17 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender