Tender For Repair/Maint Of External Water Supply System And External Electrification At Almora Under Ge Ranikhet
Tender Value
11 Lakhs
Estimated cost
Bid Submission
18 Aug 2026
17 days left
EMD
22000
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Almora → Uttarakhand
EMD Exemption
Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender for Repair/Maint Of External Water Supply System And External Electrification At Almora Under Ge Ranikhet
BOQ
| Sl. No. | Item Description |
| 1 | Taking up or down unserviceable water tubing from any position of the following sizes complete all as specified and dircted:- (a) 100mm dia bore |
| 2 | (b) 80mm dia bore |
| 3 | (c) 50mm dia bore |
| 4 | (d) 25mm dia bore |
| 5 | (e) 20mm dia bore |
| 6 | (f) 15mm dia bore |
| 7 | S&F of GI water tubing medium grade. including all GI fittings and accessories as required at site for the following sizes complete all as specified and dircted.for the following sizes (a) 100mm dia bore |
| 8 | (b) 80mm dia bore |
| 9 | (c) 50mm dia bore |
| 10 | (d) 25mm dia bore |
| 11 | (e) 20mm dia bore |
| 12 | (f) 15mm dia bore |
| 13 | Taking out old unserviceable gate valves for replacement including S&F of gun metal gate valve of 50 mm bore ISI marked class I with iron wheel head screwed both ends for iron pipe & fixed complete all as specified and directed. |
| 14 | All as per item No 13 here-in-before but 40mm bore |
| 15 | All as per item No 13 here-in-before but 25 mm bore |
| 16 | All as per item No 13 here-in-before but 20 mm bore |
| 17 | All as per item No 13 here-in-before but 15 mm bore |
| 18 | Taking out old unserviceable sluice valve for replacement including S & F new sluice valve of 80 mm size cast iron body flanged and drilled as per ISI 14846 (ISI Marked) specifications PN-1.6 with stainless nuts, bolts, washers & fibre/rubber gasket steel spindle including all accessories complete all as specified and directed. |
| 19 | Serviceing, Overhaluing, checking and Testing complete of DG Set 62.5 KVA at Pump House No - 2a) Supply and replacement of Lub oil filter, Fuel filter primary and secondary, Hose bend & Hose pipe, Air filter.b) Draing out old lubricant oil from oil sump and supply and filling of fresh lubricant oil 20 W 40 grade.c)Draing out water from radiator of engine and cleaning the same with anti rusting solution and supply and filling of coolent.d) Checking and making necessary adjustment to drive belts, Speed governor and fuel injectors for smooth function of the engine. Make:- Kirloskar |
| 20 | M & L for painting with two coat of synthetic enamelled paint of approved shade over a coat of red oxide primer on external surfaces of motor and pumps after complete removal of existing paint and preparation of steel & iron surfaces including writing SM/MES Nos with paint etc. complete all as specified and as directed. |
| 21 | Cleaning of valve pit chambers, removing algae, silt, sludge accumulated at bottom of valve pit chambers up to the entire satisfaction of Engineer in Charge. |
| 22 | Collecting samples of under ground sump water from Almora pump house for Bacteriological testing and complete Chemical testing for parameters as specified Note : The bacteriological and chemical testing of water shall be carried out in Govt authorised laboratory . The item cost includes collecting of samples of water from UG sump and Pump house site and charges of Govt authorised laboratory for carrying out testing of water sample shall be born by the contractor. |
| 23 | Material and labour for servicing of electrically driven centrifugal pump set 10 HP Motor - pump set) including greasing , cleaning and replacement of water body kit seal cup, screw ring retainer, bearing , greasing of motor, nut bolt etc. complete all as specified by the Engr-in- charge. |
| 24 | Demolition of existing unserviceable masonry valve pit including all accessories like angle iron frame, door fixed with MS sheet cover etc and M & L for construction of brick masonery valve pit of size610x610x610mm (internal dimensions) with brick work of sub class 'B' old size bricks built in cement morter 1:4 and 10mm thick rendering on internal and exposed external surface and including 40x40x6mm mild steel angle frame 3.15mm thick mild steel sheet cover in two Nos shuitters with handle and locking arrangement and 1 Nos 50mm size 4 levers lock with key in duplicate make Navtal including painting steel and iron surfaces with two coats of black bituminous paint over a coat of red oxide primer complete all as specified, shown on drawing and as directed. |
| 25 | Demolition of existing unserviceable masonry valve pit including all accessories like angle iron frame, door fixed with MS sheet cover etc and M & L for construction of brick masonery valve pit of size 1050x1050x900mm (internal dimensions) with brick work of sub class 'B' old size bricks built in cement morter 1:4 and 10mm thick rendering on internal and exposed external surface and including 40x40x6mm mild steel angle frame 3.15mm thick mild steel sheet cover in two Nos shuitters with handle and locking arrangement and 1 Nos 50mm size 4 levers lock with key in duplicate make Navtal including painting steel and iron surfaces with two coats of black bituminous paint over a coat of red oxide primer complete all as specified, shown on drawing and as directed. |
| 26 | M & L for Cleaning of complete UG sump tank capacity 50000 gallon and clear water tank 50000 gallon by carrying out following works all as specified and directed and specified by Engr-in-charge.a) Dewatering of left out water from the tanks by pumping out existing contaminated water complete with diesel engine driven pump or manually. b) Taking out complete mud/dirt and depositing the same not exceeding a distance of 500mtrs from the well/ UG Sump .c) Cleaning the tank by washing the sides and floor of the tank using scrubbers. d) Washing the tank using bleaching powder solution, removing sludge and mass from all the surface taking out the same until a clean surface is obtained, applying two coats of lime wash on walls, e) Painting the date of cleaning at a prominent place complete all as specified and as directed by Engineer-in-Charge. |
| 27 | Complete cleaning & welding of pressed steel/iron water storage tank from inside of capacity 1,91000 Ltrs capacity PS tank located at Helipad Ground, extraction of all mud/sand/dust/Algee deposits making it free from algee growth by scrapping & washing all mud/sand/dust/Algee deposits making it free from algee growth by scrapping & washing with water & painting with one coat of black bitumeneous paint all the MS items fitted inside the tank to make corrosion free incl marking of tank capacity and date of cleaning etc complete all as specified & as directed. |
| 28 | All as per item No 27 here-in-before but 80,000 Ltrs capacity PS tank located at MES Office pump house |
| 29 | All as per item No 27 here-in-before but 45,000 Ltrs capacity PS tank located at Near Army school |
| 30 | All as per item No 27 here-in-before but 41000 Ltrs capacity PS tank located at Near Army school |
| 31 | All as per item No 27 here-in-before but 10000 Ltrs capacity PS tank located at Near Army school |
| 32 | Cleaning of PVC water storage tanks of capacity exc 250 ltr but n.exc 1000 ltrs mechnized dewatening of water including sludge from the tanks, cleaning internal & external tank surfaces with high pressure water spray, vaccum cleaning, anti bacterial spray, UV radiation, spray of bleaching powder including writing date of cleaning (with thick paint in capital bold letter) on each tank etc complete all as specified and as directed by Engineer-in-charg.Note:- Rates includes the following:-(i) Opening & closing of tank covers properly before & after execution of cleaning work.(ii) Removal & refixing of float valves of any size & description before & after execution of work.(iii) Removal of sludge wher directed by Engr-in-charge(iv) User completion certificate shall be produced by the contractor.(v) If damage the tank during the cleaning, will re-fitting with new tank with contractors risk.(vi) If damege the float valve during removal for re-fitting will re-fitting the same with contractor's risk. |
| 33 | S&F of ball brass valve 15mm dia high pressure, with plythene float and flynut complete, screwed for iron pipe or brass ferrule complete all as specified and directed |
| 34 | S&F of ball brass valve 20mm dia high pressure, with plythene float and flynut complete, screwed for iron pipe or brass ferrule complete all as specified and directed |
| 35 | Supply only water tank cover for tanks of size 500Ltr or 1000Ltr complete all as specified and directed |
| 36 | Dismantling of existing LT pole any size/type from foundation in necessary earth work incl dismantling of concrete MS clamps nuts, bolts, earth wire, OH lines conductor, insulators, guarding cradles & other accessories complete all as specified and directed. (demolition of MS cross arms, earth wire, OH conductor, guarding, cradles etc. will be measured separately). |
| 37 | M & L for supply, transporting, erecting truly in vertical position and fixing of steel tubular pole swaged, over all length 9 metres, type 410 – SP – 31 complete with mild steel base plate, pole cap, finial taper plug, MS bolts, nuts & washers, necessary excavation & earthwork in hard / dense soil, PCC sub base block as mass concrete of size 600 X 600 X 150 mm in cement concrete 1:4:8 Type D-2 in base of foundation, PCC foundation block of size 600 X 600 X 1500 mm in cement concrete 1:3:6 Type C-2, pole plinth of size 600 X 600 X 300 mm in cement concrete 1:2:4 Type B-1 including necessary form work as required at site and painting of pole with two coats of anti corrosive black bituminous paint through out internally and externally upto planting depth (embedded in concrete) and remaining portion of the pole painted two coats of aluminium paint over a coat of red oxide primer on complete exposed surface including painting of 05 Nos. bands / strips of 30 cm wide each with two coats of synthetic enamel paint (black & yellow) at a distance of 30 cm from plinth block upto 1500 mm height and marking / sign writing of pole number and feeders locations of pole with thick synthetic enamel paint (white) complete all as specified and directed. |
| 38 | Material and labour for stringing, stretching and strengthening of overhead conductor (ACSR) on existing LT steel tubular pole including binding and jointing the conductor with and including 14 SWG binding wire and following sizes ACSR conductors: - (a) 6/1 X 2.59 mm aluminium and 1 X 2.59 mm steel (Weasel) (b) 6/1 X 3.00 mm aluminium and 1 X 3.00 mm steel (Ferret) |
| 39 | Supply and fixing Offload Changeover switch 200 Amp Four pole 415 volts side handle operated complete all as specified and directed.(make : Havells IHBFFE0200, Indo Asia or equivalent) |
| 40 | Supply and fixing in repair stay assembly comprising of GI stay bow 14mm dia, 40cm long, galvanised stay rod 16mm dia, 180cm long with threaded ends, GI nuts, bolts, washers, GI stay plate 23x23cmx6mm thick, 02 Nos of thimbles, MS clamps made out of 50x6mm flat iron and stay wire 7/3.15 SWG, stay clamp, loop insulator of size 65x95 mm clearance of hole 16mm complete including necessary excavation, earth work in hard dense soil and PCC 1:3:6 all as shown in electrical plate No. 01 of SSR-2009 part1 , complete all as specified and directed. |
| 41 | Dismantling and taking down U/S cross arm channels and angle from section of various sizes and shapes flat iron clamps, including nut bolts and washer and removing from site complete all as specified and directed. |
| 42 | Supply & fixing of cross arms bracing supports clamps, flat iron strips and back plates fabrication from structural steel section incl nuts, bolts washer MS pipe of required size and thickness for extension of height of pole by welding incl bending or welding cold or hot drilling holes for bolt in any shape or size as indicated or directed and inclusive of one primer coat under two finishing coat of aluminum paint as specified. |
| 43 | Dismantling and taking down u/s pin/shackle insulator of any type and size complete and removal from site complete all as specified and directed. |
| 44 | S&F Pin/shackle type insulator, porcelain, vitreous, white, brown or green of size 75mm height and 90mm dia for working pressure 1100 volts LT complete with insulator 12mm dia bolts, washers and nuts, MS strips of size 31 x 3 mm complete all as specified and directed. |
| 45 | Material and labour for earthing complete with galvanised earth plate electrode 600 X 600 X 6 mm thick burried directly in ground (earth pit not less than 2.25 m below ground level) with top edge of earth plate not less than 1.5 m below normal ground level, connected to galvanised earth strip 32 X 6 mm size by means of nuts, bolts, check nuts & washers of galvanised iron or steel all as shown on electrical plate No. 3 of MES schedule 2009, Part – I (Specifications) and connected to main switch board / main DB’s / earthing test point including all necessary excavation and earth work in any type of soil, adequate quantity of charcoal dust & common salt all around the earth plate minimum 150 mm in all directions with & including watering pipe 20 mm dia GI medium grade, GI funnel made out of 0.63 mm thick GI sheet, wire gauge, 50 mm thick RCC cover in PCC 1:2:4, type B-1 (using 20 mm graded crushed stone aggregate), duly reinforced with 6 mm dia mild steel round bars @ 150 mm both ways center to center with suitable lifting handle to cover, earth pit of PCC 1:3:6 type C-1 (using 20 mm graded stone aggregate), GI protection pipe light grade 40 mm bore up to 7.5 m length from earth electrode & engraving of earth marking on nearby building with CM 1:4 plate size 200 X 150 X 15 mm & painting of earth result etc. including testing on complete all as specified and directed. Note: - On testing after completion of job, if desired earth resistance is not obtained, the earthing shall be redone by the contractor without any extra cost to Govt at his own expenses. |
| 46 | Supply, laying, jointing and commissioning LT XLPE 1100 volts grade heavy duty cable PVC insulated, multistranded aluminium conductor served with inner sheathing of PVC tape, armoured with GI steel or tape and over all PVC sheathing laid in trenches, floor through pipes, in duct on pole and roads etc of size 120 sqmm 3.5 core. |
| 47 | All as per Srl item No 47here-in-before but sectional area 16 sqmm 4 core |
| 48 | All as per Srl item No 47 here-in-before but sectional area 16 sqmm 2 core |
| 49 | All as per Srl item No 47 here-in-before but sectional area 10 sqmm 2 core |
| 50 | Taking out unserviceable LT cable of any type and size from pole/wall/trenches by disconnecting electric connections for repair / replacement of cable complete all as specified and directed. |
| 51 | Excavation in trenches not exceeding 1.50M wide and not exceeding 1.5M depth for laying cable and getting out in hard/dense soil complete all as specified and directed. |
| 52 | Returning, filling in, trenches including spreading, leveling, watering and well ramming in layers not exceeding 25 cm thick in hard/dense soil complete all as specified and directed. |
| 53 | Removing surplus soil to a distance not exceeding 50m and depositing where directed at a level not exceeding 1.5m above starting point complete all as specified and directed.. |
| 54 | Material and labour for sand cushioning with a layer of fine sand 8 cm thick before laying the cable and 15 cm after laying the cable in trenches to cover under ground cable complete all as specified and directed. Note :-Punned down thickness of sand shall be considered for measurement) |
| 55 | Material and labour for brick protection to cable using old size class 'B' bricks of size (230x115x75mm), laid flat, dry butt jointed, laid lengthwise perpendicular to the axis of cable complete all as specified and directed by Engineer-in-charge. |
| 56 | Supply & Fixing in replacement plastic (moulded polypropylene) line phase separator (for separating 05 Nos. of over head line conductors of length 1200 mm) with 25 mm fly nuts and clamps suitable for 1100 volts grade LT electric lines of any size fixed with over head electric lines complete all as specified and directed. |
| 57 | Supply and fixing / laying of galvanized iron pipe of 150 mm nominal bore light grade for cable protection, fixed to pole/ alongwall/ floor/ under road/ across the drain or nallaha etc with clamps nuts, bolts and washers complete all as specified and directed. Note : The cost of MS clamp, nut, bolt, washer and GI fittings etc shall deemed to be included in the unit rate quoted by contractor. |
| 58 | All as per Srl item No 57 here-in-before but 25mm nominal bore of pipe |
| 59 | Dismantling of existing stay assembly any type / size from its stay rod, cutting stay rod (above ground portion) dismantling of MS clamps, nut-bolts, stay bow, loop insulators, stay wire etc. complete all as specified and directed. |
| 60 | Dismantling / taking out old ACSR conductor / copper conductor / GI earth wire any size from existing overhead lines including disconnection complete all as specified and directed. |
| 61 | M&L for one coat of aluminium shade paint of approved quality including preparation of existing old painted surface of steel tubular poles LT complete including flat iron clamps, bracing, cross arms etc and numbering of poles with white synthetic enamel paint over a circular painted base and strip marking paint up to a height of 5 feet with black & yellow five bands with synthetic paint (strip of 1 feet height each) complete all as specified and directed. |
| 62 | Supply & Fixing in repairs MCCB of Cap 100 Amp, 4pole, 25 KA, with adjustable thermal release and earth fault protection, 415 volt grade including cutting and welding work for fixing of MCCB in existing panels any type and model complete all as specified and directed.(Cat No-EM90984OOKO) |
| 63 | All as per item No 62 here in before but cap 200 Amp,36 KA |
| 64 | All as per item No 62 here in before but cap 630 Amp, 50 KA |
| 65 | Cutting/ trimming of tree branches of any width/ girth up to 1.0 mtr distance on both sides of HT/ LT over load lines including collection and depositing the retrieved timber at a place as directed by Engr-in-charge. Note :- (i) Each span have a distance 40mtr approximately (ii) All cutting branches of trees shall be thrown away/ burnt at approximate 200 to 500 mtr away as directed. |
| 66 | Material and labour for PCC 1:2:4 type B-1, using 20mm graded crushed stone aggregate as in coping of pole, floor including necessary form work where required and fair and even finish to the exposed surfaces all as specified & directed. |
| 67 | S&F synthetic insulating mat near electric installations of size 2m x lmX 3mm as specified and directed. |
| 68 | All as per item no 67 above but of size 2m x lm x 2.5 mm. |
| 69 | Material and labour PCC (1:4:8) type D2 using 40mm graded crushed stone aggregate for foundation filling of poles./struts /stay assembly including necessary form work and finishing the exposed surfaces fair and even complete all as specified and directed |
| 70 | Material and labour PCC (1:3:6) type C1 using 20mm graded crushed stone aggregate for foundation surface of poles./struts /stay assembly including necessary form work and finishing the exposed surfaces fair and even complete all as specified and directed |
| 71 | Material and labour PCC (1:2:4) type C1 using 20mm graded Providing, cement concrete in roof kerbs or mud stops, rounded or chamfered on edges, complete all as specified and directed |
| 72 | Repair and maint of damaged LED street light fittings of 35W/50W/60W/100W capacity including identification and rectification of faults to restore proper functioning. The repair work shall involve replacement of components like driver//LED chip/ module, connectors , internal wiring whereever is required |
| 73 | Supply and fixing on pole / wall Nature switch 02 EC with enclosure factory made suitable for 8 KW street light load single phase 240 volts and power contactor rating 40 Ampere with MCB 63 Ampere contactor and terminal block confirming to IEC – 60947 – 4 – 1 / IS – 13947 – 4 – 1 (Sensor alongwith pre-dawn switching off timer, 4 – 8 hours) infrared sensor based switch for intelligent outdoor street light control model No. SWADEEP – 02EC8kW1P, Make – KAKATIYA ENERGY SYSTEMS LTD. Or its equivalent approved make complete with and including mounting bracket, cable glands, openable doors with lock complete all as specified and directed. Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Jul 28, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedAug 18, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 17 daysAug 25, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 24 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender