Defence Statutory Bodies & Commissions/Committees Closing in 20 days TDR #56691891

Tender For Repair/Maint Of B/R And E/M Works For Runway (Air Field Maint) And Certain Repair Works In Otm/Md Accn At Haldwani Under Ge Ranikhet

Issued by Statutory Bodies & Commissions/Committees · Nainital, Uttarakhand
Tender Value
22.53 Lakhs
Estimated cost
Bid Submission
18 Aug 2026
20 days left
EMD
45100
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Nainital → Uttarakhand
EMD Exemption
Available
Quantity
Not Available

Project Description

Tender for Repair/Maint Of B/R And E/M Works For Runway (Air Field Maint) And Certain Repair Works In Otm/Md Accn At Haldwani Under Ge Ranikhet

BOQ

Name of Work:-
Sl. No. Item Description
1Taking up or down 20mm dia steel tubing and connections by disconnecting fittings/tubing from existing tubing were required including cleaning for refixing or removal from site complete all as specified and directed.
2M&L for 20 mm bore GI tubing, medium grade, galvanised with and including all GI fittings and fixed complete to walls and ceiling or laid in floors complete all as specified and directed.
3S&F in repair 15mm dia bib tap long body CP fancy type, screwed for iron pipes complete all as specified and directed.
4S&F in repair bib tap standard of PTMT (Polytetra Methylene Terephthalate Engineering Thermoplastic Bath fitting), any colour, screwed foriron pipe 15 mm bore pipe (minimum weight 90 gm) all as specified, fixed in repairs (Make : Prayag or Equivelent as approved)
5Dismantling water tanks 500 ltrs capacity complete all as specified and directed.
6Dismantling water tanks of any description, capacity exceeding 500 litres but not exceeding1000 liters complete.
7S&F rotational moulded polythene water storage tanks (cylindrical vertical with closed top) hoisted and fixed in postion 500 ltrs capacity and including 20mm dia ball valves, high pressure of PTMT with epoxy coated aluminium rod and high density plastic ball screwed for iron pipe minimum weight 210 gram of Make - Prayag complete all as specified and directed.
8S&F rotational moulded polythene water storage tanks (cylindrical vertical with closed top) hoisted and fixed in postion 1000 ltrs capacity and including 20mm dia ball valves, high pressure of PTMT with epoxy coated aluminium rod and high density plastic ball screwed for iron pipe minimum weight 210 gram of Make - Prayag complete all as specified and directed.
9S&F in repair PVC Fluted 8 to 9mm thick hollow PVC wall/ ceiling panelling including all fixing viz, U and L as design and pattern including all necessary framed works as per manufacturer s instruction , make as approved by GE complete all as specified and directed.
10S& F in repair PVC Flushing Cistern 10 litre capacity, Low Level Valve Less, Symphonic Action type, White, with Inlet, Ball Valve, Float and Handle including 32mm dia PVC Flush Pipe, a Pair of MS Brackets,CP flush bend including Cutting and Pinning in Ends, Making Good Disturbed Surfaces in Cement Mortar 1:3 including taking down unserviceable Flushing Cistern and connected Items of any description, complete all as specified and as directed.
11S&F in repair Stainless steel wire cloth 0.36 mm nominal dia of wire and avg aperture 1.40mm and fixed with stainless steel staples complete all as specified and directed
12Hacking out old broken glass (any thickness, size, quality or description) from metal frames incl punching or drilling out glazing pins/spring clip and providing and fixing new ones.
13S/F repair Sheet glass 3mm thick, ordinary quality and glazing with oil putty in squares exceeding 0.5 Sqm in each pane complete.
14S&F in repair Vanity Cabinet with wash basin , Owing to the high quality HDHMR Board with a gloss finish table top (Counter Top) of size 600mm x 450mm x 300mm,any shape and colour including PVC waste pipe 32mm dia & Single lever Basin Mixture( Hot & Cold) ,Incl Waste Coupling brass chromium plated complete all as specified and directed.
15Demolition of brick work built in cement mortar all as specified
16Demolition of cement concrete (unreinforced) in ground floors and pavings incuding terrazzo topping n.exc 15cm thickness (below or above ground level) and disposal of unserviceable materials, debris and rubish to a distance not exc 50m as directed by Engr-in-Charge complete all as specified.
17Material & Labour for brick work with sub class `B’ bricks, straight on plan exc 6m mean radius built in CM 1:6 complete all as specified and directed.
18M&L for PCC 1:4:8 type D-2 (using 40mm graded stone agg) as in foundation filling and mass concrete.
19Taking down cement plaster on brick or stone walls etc raking out joints hacking for key scrabbing down water etc complete.
20Material and labour for 15mm thick cement plaster in CM (1:4) on fair faces of brick or concrete surfaces using WPC where ever required as per manufacturerer's instructions and finishing the surface even and smooth (without using extra cement) etc. incl finishing even and fair complete all as specified NOTE -WPC shall be measured and paid separetely.
21M&L for rendering 15mm thick on fair faces of brick work in CM 1:6 finished even and fair without using extra cement complete.
22Supply only WPC complete all as specified and directed.
23M&L for preparation of newly plastered surfaces of wall , finishing walls with Acrylic Smooth exterior paint of required shade : New work (Two or more coat applied @ 1.67 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm) complete all as specified and directed.
24Preparing new plastered or unplastered surfaces of walls and applying two coats of distemper oil emulsion, white or tinted over & including a coat of primer complete.
25M&L for preparation of old decorated plastered or unplasteredsurfaces of walls including cornices etc by brooming down stell wire brushing, scraping down smoke soot, moulds, masss and efflorscent salts and trading oil and greasy spots & removing of nails mark & applying one coat of cement base paint on wall to match the existing surface complete all as specified
26M&L for complete removal of existing surface and applying two coat of cement base paint over a coat of primer on old decorated/undecorated surfaces of walls complete all as specified and as directed.
27Material and Labour for preparation of new/old road surfaces and applying thermoplastic reflective paint in marking of minimum 2.5mm thick single coat as in centre line and edge line road marking of 150/100 mm width using 'HOT MARK' by indigenous modern propelled road marking machine as directed including all ingredients such as binder, glass beads Titanium dioxide calcium carbonate inter filler, thermoplastic requirement for glass beads shall be the table No 800.4 of MOST specification including spraying of glass beads and removing of old existing paint etc all as per manufacture's instructions complete all as specified and directed incl removal of existing paint complete as directed by Engr-in-Charge
28M&L for 3mm Epoxy Polyurethane floor coating consisting of 200 micron thick priming coat 2000 microns screed coat and 1000 micron thick top coat including necessary preparation of the existing surface all as per the manufacturers instructions. Work to be carried out in patch work and to make the shade asper existing shade incl removing existing treatment if any complete all as specified and as directed.
29M&L for Epoxy Polyurethane floor paint coating consisting of 200 micron thick priming coat and 1000 micron thick top coat including necessary preparation of the existing surface all as per the manufacturers instructions. Work to be carried out in patch work and to make the shade asper existing shade incl removing existing treatment if any complete all as specified and as directed.
30M&L for 25mm thick PCC 1:2:4 type B-1 20mm graded stone as in level course with finshining in cement concrete surface even and rough to receive screed bed complete
31Dismantling floor, hearth , wall tiling including taking down plastering in cement mortor removing serviceable tiles to store and rubbish off the premises
32M&L Joint free Non - skid coloured ceramic tiles 7 to 10 mm thick (square/rectangular) area of each tile exceeding 0.11 sqm but not exceeding 0.18 sqm, in floors etc. set and jointed in neat cement slurry over screed bed of 15 mm thick 1:6 and pointed in white or coloured cement to match complete all as specified.
33M&L Glazed coloured ceramic tiles in verticle surfaces 450 x 300 x 7mm thick set and jointed in neat cement slurry and pointed in coloured cement to match with backcoat of screed bed or bedding layer 10mm thick 1:4 and pointed in white or coloured cement to match complete all as specified..
34M&L Joint free Non - skid coloured ceramic tiles 7 to 10 mm thick (square/rectangular) area of each tile exceeding 0.18 sqm but not exceeding 0.36 sqm, in floors etc. set and jointed in neat cement slurry over screed bed of 15 mm thick 1:6 and pointed in white or coloured cement to match complete all as specified.
35-ditto- all as per item Ser No-20 above here-in-before but in skirting/dado or verticle surfaces with back coat of screed bed or bedding layer of 10 mm thick 1:4 and pointed in white or coloured cement to match complete all as specified.
36M&L for cutting chases, pinning in, making good to facing where required and pointing in cement mortar 1:3 to ends or edges of landings, steps, cills, sunshades shelves, lintels etc, and cutting chases for concealed water tubing or concealed conduit wiring etc and making good, cutting not exc 10cm girth.
37Taking up or down GI Water Tubing 15mm dia (bore) including Connections and Fittings, segregating serviceable Pipes & Fittings and Stacking properly at Site(s) for re-use, complete all as specified and as directed.
38Supply and Laying Steel Water Tubing 15mm dia (Bore), Galvanised, ‘Medium Grade’ with all Fittings, fixed on Walls, Ceiling or laid in Floors or any other Situation, complete as all specified and as directed.
39S & F in repair brass fancy type Swan Neck Pillar taps CP Brass for iron pipe of bore 15mm fancy type with capstan head.
40S&F in repair Angle Cock,15mm fancy type, chromium plated, screwed down, high pressure, with crutch or butterfly handle, screwed both ends for iron pipe or for unions and fixed complete all as specified and as directed.
41S&F in repair PVC Connections 15mm size with PTMT Nuts of length 450mm and fixed, complete all as specified and as directed.
42S&F in repair one piece floor mounted vitreous china EWC with integrated flushing cistern, soft closing seat cover and necessary nut/bolt for fixing complete all as specified and as directed by Engr-in-Charge
43S&F in repair wash hand basin of vitreous china counter Top size 600mm x 500mm x 300mm,Including PVC waste pipe 32mm dia & Waste Coupling brass chromium plated and cutting complete all as specified and directed.
44S&F in repair Vitreous China Urinal, half stall type, including, urinal spreader, waste coupling and waste pipe complete including providing and fixing plugs, bedding urinal against wall in cement mortar 1:2, securing urinal to plugs with and including 60mm long brass screws, pointing around urinal back in cement, grating and Union for discharge pipe complete all as specified and as directed.
45Dismantling of PVC / CI pipe 75mm dia or less jointed in cement mortar and taking out of trench if required complete all as specified.
46S&F 75 mm bore PVC (SWR) pipes single socketed, in any length with rubber ring joints, laid in trenches or in floors complete all as specified and as directed
47S&F 75 mm bore PVC (SWR) bends any radius complete all as specified and as directed
48S&F 75 mm bore PVC (SWR) junction single (Single Tee) equal or unequal complete all as specified and as directed
49M&L PVC (SWR) floor trap, plain with grating including jointing with solvent cement complete all as specified and as directed
50Dismantling of PVC / CI pipe 100mm dia jointed in cement mortar and taking out of trench if required complete all as specified.
51S&F 110 mm bore PVC (SWR) pipes single socketed, in any length with rubber ring joints, laid in trenches or in floors complete all as specified and as directed
52S&F 110 mm bire PVC (SWR) bends any radius complete all as specified and as directed
53Taking down chowkats or frames exc 1.50 sqm but n.exc 4.00sqm each with shutters (without taking off shutters from the frames) complete..
54Taking down chowkats or frames n.exc 1.50 sqm each with shutters (without taking off shutters from the frames) complete.
55S&F of 12 mm thick Toughned Glass Door with patch fittings with cover plate of SS-304 Grade including Decorative type Stainless steel 304 grade floor Spring, fixing/moving arrangement at top, Stainless steel 2 Nos H Type Handles of 450 MM suitable size as directed, Fin Connect Patch Lock etc in each door, including cutting holes in any size in floor and wall complete all as specified and as directed by Engineer-in-Charge.Make : All fittings shall be Ozone or equivalent .
56M&L for providing PCC 1:2:4 type B-0 as in roof kerbs or mud stops rouded or chamfered on edges (using 12.5mm graded stone aggregate) complete all as specifed and directed.
57Dismantling wrought iron or mild steel work of any description not otherwise provided for complete all as specified and as directed
58S&F Rolled sections channel angle Tee section and in tubular section as in main and cross beams, hip and jack rafters; purlins,post where connected to common rafters and running rails and embbeded in concrete complete .
59Dismantling wall and ceiling boards, any thickness incl cover fillets complete.
60S&F powder coated aluminium anodised snap grid frame work for false ceiling comprising of the following sections for making partitions of 605x605 mm size fixed to walls with rawl plugs & screws and hanged to roof with and including 2mm dia GI wire suspender of suitable length and butterfly clips, size of main tee shall be 37mmx24mmx0.3 mm thick , cross tee shall be 28mmx24mmx0.3mm thick and wall angle shall be 24mmx24mmx0.3 mm thick complete all as specified and directed.
61S&F 4mm thick non asbestos E-board cememt building board for insulation and accoustic purpose, 600 x 600 mm size fixed with staples on snap grid as in ceiling complete all as specified and directed.
62Supply & fix in repair Hand Shower (health faucet) CP Brass 15 mm bore with 1 meter long easy flex tube in chrome finish and wall hook with NRV (Back Flow Preventer) as approved by the GE. Make- Jaquar or equivalent
63S&F in repair door closer aluminium extruded section hydraulically regulated, designation No 3, universal type, suitable for door shutters of 851 to 1000 mm in width and of weight between 61 to 80kg and fixed
64Supply and fixing factory made uPVC white colour Casement door with 3D hinges made of (big series) frame 67 x 64 mm & sash 67 x 110 mm both having wall thickness of 2.3 ± 0.2 mm and single glazing bead / double glazing bead of appropriate dimension comprising of uPVC multi-chambered frame, sash and mullion (where ever required) extruded profiles duly reinforced with 1.60 ± 0.2 mm thick galvanized mild steel section made from roll forming process of required length (shape & size according to uPVC profile), uPVC extruded glazing beads of appropriate dimension, EPDM gasket, zinc alloy (white powder coated) 3D hinges and one handle on each side of panels along with zinc plated mild steel multi point locking having transmission gear, cylinder with keeps and one side key, G.I. fasteners 100 x 8 mm size for fixing frame to finished wall and necessary stainless steel screws etc. Profile of frame & sash shall be mitred cut and fusion welded at all corners, mullion (if required) shall be also fusion welded including drilling of holes for fixing hardware's and drainage of water etc. After fixing frame the gap between frame and adjacent finished wall shall be filled with weather proof silicon sealent over backer rod of required size and of approved quality complete all as specified and directed by Engineer-in Charge. (Glass shall be paid separately) Note: For uPVC frame, sash and mullion extruded profiles minus 5% tolerance in dimension i.e. in depth & width of profile shall be acceptable. Variation in profile dimension in higher side shall be accepted but no extra payment on this account shall be made made sepreately.
65M&L for one coat of synthetic enamel paint to old decorated steel surfaces of girth exc 10cm including preparation of surfaces complete
66S&F Factory made single extruded WPC (wood polymer Composite) solid door/ window/ Ceosetory window & other Frames/ Chowkhat of size 45 x 70 mm comprising of PVC polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wwod powder/ rick husk/ wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms ) fabricated with miter joints after applying PVC solvent cement and screwed with full body threaded stat headed SS screws having minimum frame density of 750 kg/ cum, screw withdrawal strength of 2200 N (Face) & 1100 N (Edge), minimum compressive strength of 58 N/mm2, modules of elasticity 900 N / mm 2 and resistance to spread of flame of Class A catogory with property of being termite/ borer proof, water / moisture proof and fire retardant and fixed in position with MS hold fast/lugs / SS dash fasteners of required dia and length complete as per direction of Engineer-in-Charge
67S&F Factory made single extruded WPC (wood polymer Composite) solid plain flush door shutter of 30 mm thick comprising of virgin polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/ wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) having minimum density of 650 kg/ cum and screw withdrwal strength of 1800 N (Face) & 900 N (Edge), minimum compressive strength 50 N mm2 modulus of elasticity 850 N / mm2 and resistance to spread of flame of Class A catogary with property of being termite/ borer proof, water/ moisture proof and fire retardanat and fixing with stainless steel butt hinges of required size with necessary full body threaded star headed counter sunk SS screws, all as per direction of Engineer-In-Charge (Note:- stainless steel butt hinges shall be paid separately complete all as specified and directed.
68S&F Aluminium alloy, anodised, sliding door bolt with haps, staple (bolt type) and fixing clips with sheet, cast and extruded section and fixing bolt and sliding bolt of extuded sections or cast aluminium alloy and fixed 300 mm long complete all as specified and as directed.
69S & F aluminium handle, cast type anodized 150mm size.
70S & F 200 mm long aluminium anodized barrel tower bolts of extruded section lcomplete all as specified and as directed.
71Supply & fixing butt hinges medium weight cold rolled mild steel of 100mm long complete all as specified and directed.
72S&F in repair Aluminium alloy, anodised, sliding door bolt with haps, staple (bolt type) and fixing clips with sheet, cast and extruded section and fixing bolt and sliding bolt of extuded sections or cast aluminium alloy and fixed 300 mm long complete all as specified and as directed.
73S & F in repair aluminium handle, cast type anodized 150mm size.
74S & F in repair 200 mm long aluminium anodized barrel tower bolts of extruded section lcomplete all as specified and as directed.
75Supply & fixing in repair butt hinges medium weight cold rolled mild steel of 100mm long complete all as specified and directed.
76S&F in repair Brass CP Wall mixer for mixing hot & cold water (3 in 1) screwed down for iron pipe and fixed bore of pipe 15mm complete all as specified .
77Dismantling plain or corrugated steel sheeting, any gauge, thickness as in roof coverings.
78S&F prepainted aluminium zinc corrugated steel sheet (galvalume base) or thinknee 0.50mm having tensile strength of 550 MPA , in colour and profile as apporved by GE and to be facotry moulded as in roof covering /cladding and fixed with hot dipped galvanished with high durable protective triple coated self tapping screws /self drilling serews, to suit the roofing in customized colour matching with the colour of roofing and screws are to be fixed using torque adjustable electronic gun screws drills of suitable capacity complete all as specified
79S&F prepainted aluminium zinc plain steel sheet (galvalume base) or thinknee 0.50mm having tensile strength of 550 MPA , in colour and profile as apporved by GE and to be facotry moulded as in roof covering /cladding and fixed with hot dipped galvanished with high durable protective triple coated self tapping screws /self drilling serews, to suit the roofing in customized colour matching with the colour of roofing and screws are to be fixed using torque adjustable electronic gun screws drills of suitable capacity complete all as specified.
80Supply , laying , connecting, testing and commissioning of 70 Sqmm 3.5 core earthed system under ground LT XLPE insulated screened, PVC bedded, armoured heavy duty electric cable with stranded aluminium conductor 1100 Volts laid in trenches, fixed to walls/ drawn through pipe with suitable size glands, crimping type lugs and incl the disturbence surface of road making good with using PCC etc all as specified of the following sizes. Complete as specified and directed by Engr-in-Charge. Note;-(Excavation, earthwork send cushioning and cable protection shall be measured and paid for separately.)
81Supply , laying , connecting, testing and commissioning of 25 Sqmm 4 core earthed system under ground LT XLPE insulated screened, PVC bedded, armoured heavy duty electric cable with stranded aluminium conductor 1100 Volts laid in trenches, fixed to walls/ drawn through pipe with suitable size glands, crimping type lugs and incl the disturbence surface of road making good with using PCC etc all as specified of the following sizes. Complete as specified and directed by Engr-in-Charge. Note;-(Excavation, earthwork send cushioning and cable protection shall be measured and paid for separately.)
82Taking down existing panel and Supply, installation and testing of LT Feeder Pillar (prewired) board outdoor type made with CRCA sheet minimum 3.15mm thick suitable for 415 Volt, 50 Hz, the feeder pillar panel should be CPRI certificate IP-54 with switchgear complete with dust and vermin proof, rain shed on top, Panel board should have front and rear opening with hinged double door and rubber gaskets, handles, industrial lucking arragements, earthing terminals, affixing danger notice board and anti rust coating , suitable cable entry and exist hole including cable glands with angle base (50 x 50 x 6) mm fixing in PCC with suitable size of panel (a) INCOMING: MCCB 125 Amps 4 Pole, 415V, 35 KA-01 Nos. (b) Aluminium Bus bar capacity 200 Amps- For three phase and neutral as per requirement at site. (c) Out going : MCB TPN 125 Ams-01 Nos(d) industrial plug socket 63 Amp 3P+N+E with DIN rail, IP-67 complete with one triple pole MCB 415V 63 amps-01 (c) Ammeter Digital Type-01 Nos.(d) Voltmeter Digital Type-01 Nos. (e) Amp selector switch-01 Nos(f) Voltmeter selector switch - 01 Nos. (g) LED indicating lamp (R, Y,B)-01 Nos.
83Excavation in trenches not exceeding 1.5 mtr wide, depth exceeding 1.5 mtr and getting out in hard/dense soil complete all as specified and directed by Engineer-in-charge
84Returning, filling incl spreading, levelling, watering and well ramming in layers not exc 25 cm in hard/dense soil all as specified and directed.
85Removing excavated material (soil) not exc 50 mtr and depositing where directed at a level not exc 1.5 mtr above the starting point complete all as specified and directed.
86M&L for dry clean sand filling in trenches below and around under ground cable cushioning complete all as specified and directed.. Note :- Thickness of sand cushioning shall be measured after punning.
87Supply and fix unreinforced PCC cable cover class LV type I of size 250x150x40mm. Complete as specified and directed by Engr-in-Charge
88Taking down carefully of existing 200 watt Hi-bay light fitting and supply, fixing and testing of 200 watt rugged radial LED hi-bay light for varied industrial applications hangging on top complete. Make:- Havells cat pat No BAYBRITESAUCERHBP200WLED757WBTOLTG or equivalent cat pat in make wippro/ Phillips/Bajaj/C&SNote:- (i) The work to be carried at an hight of 14 to 16 meter and no extra shall be paid on this account. The rate should be deemed to be inclusive of this aspect. Contractor will be responsible for any type of accident while carried out the work by labours and all safety measures carried out during exection of work. (ii) Contractor shall submit 2 year warrenty of material from manufracturer alongwith purchase voucher.
89M&L in repairing/replacement of burnt and damage part of sliding doors of hanger consisting of following works :-(a) Repair and overhauling of elect motor 3.5 HP capacity installed for moving of gates of hanger. (b) Dismantling of 3.5 HP elect motor 3 phase, 440 volts from hanger door and taking away local works shop and transporting back the same after repairs to its original position complete.(c) Opening of motor winding, cutting of burnt coils and cleaning of slots and replacing the old burnt coils complete all as specified and directed.(d) Applying one coat of red oxide primer, fixing of packing with Pnumax paper and green sheet of glass cloth, rewinding with suitable gauge of super enamelled insulated wire incl condenser.(e) Varnishing with doctor bake varnish, during backtrol and heating properly.(g) Replacement of u/s chain, chain gear and greasing to brgs complete. (l) M&L in repair of starter panel box (Door opening panel) including replacement of burnt contactor, ICs, fuses, ON/OFF siwtch (NO/NC switches), Relay etc and checking of electrical connection throughly and making the door in operational condition with repair hinges of opening control panel box by repair or welding to proper close the door of paenl box for the entire satisfaction of GE/Engr-in-Charge. Notes :- (i) The rates for replacement/repaired should be treated to be incl in the rated quoted by contractor incl all necessary fitting and fixtures reqd at the site of work. Nothing extra shall be provided on this account complete all as spicified and directed. (ii) Standby electric motor of 3.5 HP should be provided by contractor at the site for operation of hanger doors.
90Material & Labour for servicing of silent DG set capacity 250 KVA (Three phase diesel engine driven Generator set) complete all as specified and directed. Comprising of the following works :-(a) Overhauling of Self starter assy including required defective part.(b) Replacement of engine oil filters -02 Nos (c) Replacement of diesel filters - 02 Nos (d) Replacement of Air filter - 01 Nos. (e) Replacement of engine oil of required cap with specified grade - 26 Ltr (Approx)(f) Replacement of alternator carbon bushes.(g) Fan belt as per sample - 03 Nos (h) Replacement of alternator bearing of required size - 02 Nos (j) Replacement slipering assy - 01 Nos (k) Replacement of coolant of required cap.(i) Replacement of Battery 12 V, 180 Ah - 02 Nos (m) Replacement of proximate coolant sensor complete with wiring connection. (n) Replacement of LOP (Low oil pressure) indicator sensor - 01 Nos (o) Replacement of door lock - 04 Nos (p) Replacement of fuel tank cap with lock - 01 Nos (q) Replacement of unserviceable ARB card - 01 Nos
91Supply and fixing, replacement of unserviceable 100 watt incandescent lamp with glassdoor shed screwed type suitable for H type standing indigator complete all as specified and directed.
92M&L in replacement of unserviceable old halogen lamp with 200 W, 6.6 A halogen lamp suitable for elevated type uni/semi directional high intensity approach light/PAPI fitting .
93M&L in replacement of unserviceable old halogen lamp with 45 W, 6.6 A halogen lamp suitable for elevated omni directional type medium intensity approach light fitting.
94Supply and fixing industrial plug and socket 63 Amp 3P+N+E with DIN rail, IP-67 complete with one triple pole MCB 415V 63 amps complete all as specified and directed
95Supply and fixing industrial plug and socket 32 Amp 3P+N+E with DIN rail, IP-67 complete with one triple pole MCB 415V 32 amps complete all as specified and directed
96Material & Labour for servicing of Electrically operated overhead travelling (EOT) Crane-5 Ton,3 phase 4 wire 415 Volts double girder Medium (III) height-9000mm, Running Lengh-75000mm Pendent Control, Make:-M/s Rock Well Hoisto Crane Pvt Ltd complete all as specified and directed of Engr-in-Charge. Comprising of the following works :-(a) Replacement of Oil 15 to 20 Ltr Approx..(b) Repair/Replacement of Unserviceable Contactor, Relay, MCB and MCCB in control panel box. (c) Repair/Replacement of Rope.(d) Repair/Replacement of Winding of 3 phase motor if not running. (e) Working load test .(f) Greasing of all running parts of crane. Note:- Servicing of Crane should be done authorised dealer and certificate also given by contractor regarding servicing and load test with duly signed by authoriesed dealer .
97M&L Servicing of indoor and outdoor unit of split type/ window AC of 1.5/2.0/3.0 ton capacity of any make by air blowing, cleaning the filter in water and drying in sun, cleaning of drain tray and rectifing water leak, checking and tightning the electrical connection incl provide insulation material on copper pipe cooling coil and heating coil etc all as specified and directed by Engr-in-charge.
98M & L for Supply and Refilling Gas/refrigerant (CFC free) in AC 1.5 ton / 2 Ton complete all as specified and directed
99Supply and fixing replacement of unserviceable LED luminaire 600 mm x 600 mm, 36 watt, 220 V, AC, recessed type (warm/milky white as required on site) with high efficiency PMMA diffuser soft glare free light complete with driver, holders & LED lamp suitable for roof ceiling, life of tube light not less than 50,000 hours including connecting up with driver three core flexible copper conductor cable of suitable size complete.Note:- Contractor shall submit 2 year warrenty of material from manufracturer alongwith purchase voucher.
100M&L for taking out burnt/damaged fan motor of Desert cooler and supply and fixing new fan motor with 26/27 SWG of enameled copper winding wire with bearing / bushes and including provision of 23/0.0076 copper flexible twin core not less than 3 meter in length with two pin top plug etc. and make the desert cooler in operational condition complete all as specified and directed. Comprising of the following works :- (i) Replacement of water pump including water pipe (Complete set). (ii) Replacement of Fan blade (PVC/Iron) as required on site. (iii) Replacement of desert cooler front grill (Fiber/Steel/Plastic as required) including switch, indicator and regulators. (iv) Checking & tightening the electrical connection (v) Replacement of wood wool (Grass Air cooler cooling pad) suitable of iron/Plastic body desert cooler (vi) Replacement of side grill (sets of 3) for holding wood wool/cooling pads. (vii) Replacement of fan condenser 3.15/4.0 mfd.
101M&L for taking down ceiling fans / wall mounted fans of any size / sweep after disconnecting the wire from existing ceiling rose and refixing the same after painting the same with synthetic enamel paint by spray machine including filter after cleaning dust, taking out burnt/damaged winding, bushes & cleanig of stator and rotor incl etc. Rewinding with 26/27 SWG of enamelled copper winding wire replacement of bearing /bushes, condencer 2.5/4 mfd handing and testing of fan with and including provision of 23/0.0076 copper flexible core twin core not less than 1.5 meter in length and make the fan operational with a guarantee period of one year after installing the repair fan complete all as specified and directed.
102M & L for repair of true online UPS system 10 KVA, input 415 V, (340 to 440V),3 Phase 50 Hz (47 to 53 Hz)Out put voltage- 230V, Single phase including replacement of burnt/defective part of the system and making the system in operational condition, consisting with following works :-(a) Checking of operational mode of system (Normal, Battery, Bypass, Manual Bypass, ECO mode, Auto restart mode etc.).(b) Checking of electrical connection throughly .(c) Replacement of rectifier, bypass indicator, diode, capacitor, ICs, and inverter, load/unload indicator etc and other electronics component required on site. (d) Replacement in repair bettary of capacity 12V, 26 Ah - 28 Nos (d) Repairing of deffective/burnt/unserviceable part of rectifier and invertor and making the system in operational condition complete all as specifiec and directed.
103S & F exhaust fan made of sturdy Engineering plastic type ISI Mark, copper winding of sweep 250 mm size complete with louvers including cutting opening through brick/stone /PCC block wall, making of holes and grouting of suitable size of nuts and bolts for 300 mm exhaust fan and making good dismantled portion and making connection with wire of suitable size and connecting accessories complete all as specified and directed.
104S & F exhaust fan mettalic body ISI Mark, 300 mm size with blades, frames and louvers including cutting opening through brick/stone /PCC block wall, making of holes and grouting of suitable size of nuts and bolts for 300 mm exhaust fan and making good dismantled portion and making connection with wire of suitable size and connecting accessories complete all as specified and directed.
105Taking down carefully aluminium/copper wiring of any size (for light, fan, socket or power etc complete) including fixture and fittings such as switches, sockets, ceiling roses, pendent holders regulators, tube lights, bells etc and making good disturbed surfaces of wall, roof etc to match with existing surface.
106Supply & Fixing point wiring for one light point/ fan point controlled by one, one way switch with 1.5Sqmm size, PVC insulated and unsheathed 1100volts grade, single core stranded (multistrand) copper conductor (FRLSH) PVC cable drawn into & including PVC casing/capping and accessories including sunk cast iron or pressed steel terminal boxes for mounting fittings like switches, sockets & fan regulators etc with 3 mm thick plastic laminated sheet covers fixed with brass screws and cup washers including one continuous run of PVC insulated (green colour) 1.5 Sqmm multistranded copper conductor cable earth wire and connected to earth, etc and making good disturbed surfaces of wall, roof etc to match with existing surface complete all as specified and directed (Note:- wiring shall be done in colour coding as directed by Engineer in charge)
107All as per item No.106 herein before but one bell point controlled by one switch
108All as per item No.106 herein before but one socket outlet 5 Amps on the same board.
109All as per item No.106 herein before but one socket outlet 5 Amps on independent board
110All as per item No 106 herein before but wiring with 2.5sqmm copper wire (FRLSH) PVC and 2.5 sqmm earth wire for socket outlet 5 pin 15 amps on independent board.
111All as per item No 106 herein before but wiring with 4.0sqmm copper wire (FRLSH) PVC and 4.0 sqmm earth wire for socket outlet 5 pin 15 amps on independent board.
112Supply & Fixing lamp holder (dome type) PVC insulated body with cord grip cap for angle/battern fitting complete all as specified and directed.
113Suppy & Fixing switch piano flush type single pole, one way 6 Amp complete all as specified and directed.
114Supply & Fixing switch piano, flush type single pole 16 Amp complete all as specified and directed.
115Supply & Fixing socket outlet 2 in 1, 3 pin, 6 and 16 Amp flush type complete all as specified and directed.
116Supply & Fixing socket outlet 2 in 1, 3 pin, 6 Amp flush type complete all as specified and directed.
117Supply & Fixing Bell push, flush type, 5 Amp complete all as specified and directed.
118Supply & Fixing steped type electronic fan regulator flush type on the existing phenolic laminatedsheet etc.
119Supply & fixing Bell AC 230 volts, 50 Hz single pole complete all as specified and directed.
120Supply & Fixing ceiling rose, PVC/ Poly carbonate, isolated body three terminal complete all as specified and directed.
121Supply and fixing LED lights T-5 fitting 1x 20W (warm/milky white as required on site), 220V, AC with driver, holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose 1.5 RM and life of tube light not less than 50,000 hours complete all as specified and directed..Make Havells/Phillips/Bajaj/C&SNote:- LED tube light shall be purches to get minimum 2 year warrenty of material from manufracturer.
122Supply & Fixing sheet metal enclosure with socket plug top and MCBs Single pole and neutral enclosure 240 Volt with a two pin and earth plug and socket complete with on single pole MCB 20 Amp complete including taking down unserviceable sheet metal enclosure of any make and type including teakwood board etc complete and making good the disturbed surfaces including colour wash complete all as specified and directed.
123Supply & Fixing sheet metal enclosure for DBs(double door type) single pole and neutral 4 way including blanking plate as required with 200 Amps rated bus bar, 240 volts fixed including taking down unserviceable main switches MCB DB’s of any make and type including teakwood board etc complete and making good the disturbed surfaces including colour wash complete all as specified and directed.
124All as per item No. 123 herein before but 8 way
125Supply & Fixing sheet metal enclosure for DBs(double door type) Triple pole and neutral 4 way including blanking plate as required with 200 Amps rated bus bar, 415 volts fixed and concealed in wall including taking down unserviceable main switches MCB DB’s of any make and type including teakwood board etc complete and making good the disturbed surfaces including colour wash complete all as specified and directed.
126Supply & Fixing 240V, 10KA 'B' curve miniature circuit breaker (MCB) of single pole and current carrying capacity 5 to 32 Amp, in the MCB DB complete with connection testing and commissioning complete all as specified and directed .
127Supply & Fixing 240V, 10KA 'C' curve miniature circuit breaker (MCB) of single pole neutral (SPN) and current carrying capacity 40 to 63 Amp, in the MCB DB complete with connection testing and commissioning complete all as specified and directed .
128Material and labour for Sub main wiring with 2 run of 4Sqmm (nominal area) FRLSH, PVC insulated, unsheathed and stranded copper conductor cable ISI marked, drawn in to and including Rigid non metallic PVC conduit ( ISI marked) Heavy grade, 20 mm dia (external) inclusive of junction/terminal boxes, all fittings and accessories fixed PVC Casing Caping with and including 4 Sqmm (nominal area) FRLSH, PVC insulated, unsheathed and stranded copper conductor cable ISI marked as earth wire, connected with thimble from main DB to sub main DB including cutting and chasing and making good surface as original by plastering and whitewash/ colour/ distemper etc including taking down existing old sub main wiring complete all as specified. Note :1 The cost of earth wire is included in the quoated rates. 2. Two run of 4 sqmm and one run of 4 Sqmm incl PVC conduit will be measured as one unit ie one running metre”
129Material and labour for Sub main wiring with 2 run of 2.5 Sqmm (nominal area) FRLSH, PVC insulated, unsheathed and stranded copper conductor cable ISI marked, drawn in PVC casping caping ( ISI marked) Heavy grade inclusive of junction/terminal boxes, all fittings and accessories fixed and including 2.5 Sqmm (nominal area) FRLSH, PVC insulated, unsheathed and stranded copper conductor cable ISI marked as earth wire, connected with thimble from main DB to sub main DB including cutting and chasing and making good surface as original by plastering and whitewash/ colour/ distemper etc including taking down existing old sub main wiring complete all as specified. Note :1 The cost of earth wire is included in the quoated rates. 2. Three run of 2.5 sqmm and one run of PVC conduit will be measured as one unit ie one running metre”
130M&L for MCCB 4 pole 415V adjustable type 200 Amps with breaking capacity 36 KA complete all as specified and directed by Engr-in-Charge.
131Repair/ Servicing and Repalacement of Old Unserviceable components of CCR Panel Such as circuit breakers, relays, motor control oversight, programmable logic controllers (PLCs), thyristor stacks, transformers, fuses, filters, and terminal blocks Card ,Fuses indoor type Constant Current Regulator of Thyristor control electronic type, suitable for use on 415V/240 V Input, Supply voltage 50 Hz, output power with tapping and output current as details below with 5 step current variation suitable for local and remote control operation with 24 V/48 DC control supply with complete digital output ammeter (0-30 or 0-10 Amps) over current, open circuit , earth fault protections, earth leakage Meter, & positive back indication equipments with complete 5 KV grade current transformer 20/10/1 Amps and relay contacts Cap 4 KW 6.6 Amp/20 Amps for Taxi light/Runway Edge Light as complete all as specified and directed by Engr-in-Charge.
132Dismantling of old unserviceable wall-mounted starter panel and supply, installation, testing and commissioning in all respects of new wall-mounted starter panel in sheet metal enclosures suitable for operation of existing 3.5 HP, 3-phase, 440 volts electric motor for back-and-forth movement of hangar gates, complete with accessories such as digital multifunction meter comprising voltmeter, ammeter and frequency meter, MCCB/MCB TPN, contactors, overload relay, ON/OFF push buttons, emergency stop switch, indication lamps, internal wiring and all connected accessories, complete all as specified and directed by the Engineer-in-Charge.
133Repair/ Servicing and Repalacement of Old Unserviceable components of motorized hanger door control panel like MCCB/MCB Contractors, overload relay, push buttons, emergency stop, indication lamps, internal wiring and connected accessories complete all as specified and directed by Engr-in- Charge. Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 56691891
AUTHORITY Statutory Bodies & Commissions/Committees
TENDER VALUE 22.53 Lakhs
LAST DATE 18-08-2026
Authority
Authority Name Military Engineer Services
Work Description Tender for Repair/Maint Of B/R And E/M Works For Runway (Air Field Maint) And Certain Repair Works In Otm/Md Accn At Haldwani Under Ge Ranikhet
Basic Detail
Tender No GE/RKT/80 OF 2026-27
Bidding Type Tender
Location
City Nainital
State Uttarakhand
Key Dates
Publish Date 28 Jul 2026
Submission Date 18 Aug 2026
Open Date 25 Aug 2026
Finance
Tender Value 22.53 Lakhs
Tender Fee 500
EMD 45100
Exemption Available
Document List
03SCHOFCREDIT.pdf
396cdd89-3ae0-433f-b92a-6db828a9f54a.html
BOQ_875072.xls
tenderdoc80.pdf
Tendernotice_1.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Jul 28, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Aug 18, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 20 days
Aug 25, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 27 days

Tender Documents

Download All (ZIP) ↓
pdf

03SCHOFCREDIT.pdf

html

396cdd89-3ae0-433f-b92a-6db828a9f54a.html

xls

BOQ_875072.xls

pdf

tenderdoc80.pdf

pdf

Tendernotice_1.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail
Loading tenders