Defence Statutory Bodies & Commissions/Committees Closing in 27 days TDR #56691890

Tender For Maintenance And Repairs To Distribution Transformers, Apfc Panels Voltage Stabilizers And Connected Lt Network For Ascon Nodes, Ramgarh & Dabla Under Ge (A) Jaisalmer.

Issued by Statutory Bodies & Commissions/Committees · Jaisalmer, Rajasthan
Tender Value
40 Lakhs
Estimated cost
Bid Submission
25 Aug 2026
27 days left
EMD
80000
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Jaisalmer → Rajasthan
EMD Exemption
Available
Quantity
Not Available

Project Description

Tender for Maintenance And Repairs To Distribution Transformers, Apfc Panels Voltage Stabilizers And Connected Lt Network For Ascon Nodes, Ramgarh & Dabla Under Ge (A) Jaisalmer.

BOQ

Name of Work:- Maintenance and repairs to distribution transformers, APFC Panels Voltage stabilizers and connected LT network for ASCON Nodes, Ramgarh & Dabla under GE (A) Jaisalmer.
Sl. No. Item Description
1Taking down and disconnecting defective transformer 11/0.433 KV of capacity upto 63 KVA to 100 from foundation/ pole by using crane and transporting to workshop or factory (authorised for such repair) for repair after disconnecting HV side HT cable or HT aluminium conductor and LV side LT cable , dismantling the same for repair & renewal of unserviceable parts and reassembling complete ,spray painting with two coats of synthetic enamelled grey paint after preparation of old surface writing MES No with white paint of suitable size letter and transporting back from workshop to site, installation on plate form/pole, testing & commissioning to entire satisfaction of Engineer-in-Charge.NOTE :- Spare parts ie, transformer oil, copper winding wire for rewinding will be measured and paid separately under supply only.
2Taking down and disconnecting defective transformer 11/0.433 KV of capacity upto 160 KVA to 250 from foundation/ pole by using crane and transporting to workshop or factory (authorised for such repair) for repair after disconnecting HV side HT cable or HT aluminium conductor and LV side LT cable , dismantling the same for repair & renewal of unserviceable parts and reassembling complete ,spray painting with two coats of synthetic enamelled grey paint after preparation of old surface writing MES No with white paint of suitable size letter and transporting back from workshop to site, installation on plate form/pole, testing & commissioning to entire satisfaction of Engineer-in-Charge.NOTE :- Spare parts ie, transformer oil, copper winding wire for rewinding will be measured and paid separately under supply only.
3M&L for taking out unserviceable core and limb and HV/LV winding of transformer and taking out burnt copper winding wire cleaning carefully and rewinding the same with new superior quality 99.99% pure copper enamelled wire as per existing gauge including insulating material for transformer 63 KVA to 250 KVA complete all as specified & directed by Engineer-in - Charge.
4Taking out old transformer oil and M&L new transformer oil of dielectric strength 50 KV minimum for voltage stablizer, transformer, type factory sealed with test certificate complete all as specified & directed by Engineer-in - Charge.
5Dehydration of transformer oil (mounted on poles/platform etc) with the help of filtering and drying plant by mechanical machines of suitable capacity to achieve dielectric strength of 50 KV complete all as specified and directed by Engineer-in-Charge.(Note : For any capacity of Transformer)
6S&F in replacement of HT brass stem of transformer 63 KVA to 250 KVA complete all as specified & directed by Engineer-in - Charge.
7S&F in replacement of LT brass Stem with nuts, washers of transformer 11/0.433 KV of capacity 63 KVA to 250 KVA complete all as specified & directed by Engineer-in - Charge.
8S&F in replacement of breather assembly with new silica gel of transformer 11/0.433 KV of capacity 63 KVA to 100 KVA complete all as specified & directed by Engineer-in - Charge.
9S&F in replacement of breather assembly with new silica gel of transformer 11/0.433 KV of capacity 160 KVA to 250 KVA complete all as specified & directed by Engineer-in - Charge.
10Supply and fix in replacement of Synthetic rubberised gaskets for top cover of transformer for 11/0.433 KV 63 KVA to 100 KVA capacity complete.
11Supply and fix in replacement of Synthetic rubberised gaskets for top cover of transformer for 11/0.433 KV 160 KVA to 250 KVA capacity complete.
12Taking down old unsv gasket and supply and fixing new Synthetic rubberised gaskets for HT bushing of transformer for 11/0.433 KV 63 KVA to 100 KVA capacity complete.
13Taking down old unsv gasket and supply and fixing new Synthetic rubberised gaskets for HT bushing of transformer for 11/0.433 KV 160 KVA to 250 KVA capacity complete.
14Taking down old unsv gasket and supply and fixing new Synthetic rubberised gaskets for LT bushing of transformer for 11/0.433 KV 63 KVA to 100 KVA capacity complete.
15Taking down old unsv gasket and supply and fixing new Synthetic rubberised gaskets for LT bushing of transformer for 11/0.433 KV 160 KVA to 250 KVA capacity complete.
16Excavation in trenches not exceeding 1.5m wide and not exceeding 1.5m in depth for foundation, laying of cable/pipe etc not exceeding 10 sqm on plan and getting out in Soft/disintegrated rock complete all as specified & directed by Engineer-in-Charge.
17Excavation in trenches, n exc 1.5m wide and n exc 1.5m in depth , for foundation, etc or for shafts, wells, cesspits, manholes, pier holes, laying of cables etc. n exc 10sqm on plan and n exc 1.5m in depth and getting out in soft/loose soil complete all as directed at site.
18Excavating in trenches, not exceeding 1.5m wide and exceeding 1.5m but not exceeding 3.00m depth for foundation etc or for shaft, wells, cesspits, manholes, pier holes etc not exceeding 10 sqm on plan and n exc 1.5 m in depth and getting out in soft/ disintegrated rock complete all as specified & directed by Engineer-in-Charge.
19Returning, filling in, including, spreading, levelling, watering and well ramming excavated Soft/loose soil in layers all as specified & directed at site.
20Returning, filling in, including, spreading, levelling, watering and well ramming in layers not exceeding 25 cm thick soft/disintegrated rock all as specified & directed by Engr-in-Charge.
21Removing excavated material to distance n. exc 50m and depositing where directed at a level n. exc 1.5m above the starting point complete all as directed.
22Supply, laying and testing in repair XLPE HT cable , insulated, screended, PVC bedded, galvanised steel strip or wire armoured, electic power cable (heavy duty) with aluminium conductor, conforming to IS : 7098 (Part II), 11 KV, ISI marked, cross sectional area 95 Sqmm, 3 core laid in pipe/ducts/ trenches/ under floor/ under road complete and including taking down old unsv cable complete all as specified
23Supply, lay, test and commissioning in repair LT UG, XLPE insulated, heavy duty, 1100V grade of size 185 Sqmm 3½ core electric cable with aluminum conductor, served with an inner sheathing of PVC tape armored with galvanized steel wire or tape and overall PVC sheathed, laid in trenches or passing through pipe, making all connections with and including provision of necessary glands, lugs, bushing etc as required complete and incl taking down old unsv cable complete all as specified and as directed by Engineer-in-Charge.Note : Earthwork excavation,DWC GI protection pipe shall be measured and paid separately in their respective items.
24Supply, lay, test and commissioning in repair LT UG, XLPE insulated, heavy duty, 1100V grade of size 120 Sqmm 3½ core electric cable with aluminum conductor, served with an inner sheathing of PVC tape armored with galvanized steel wire or tape and overall PVC sheathed, laid in trenches or passing through pipe, making all connections with and including provision of necessary glands, lugs, bushing etc as required complete and incl taking down old unsv cable complete all as specified and as directed by Engineer-in-Charge.-Note : Earthwork excavation DWC, GI protection pipe shall be measured and paid separately in their respective items
25Supply, lay, test and commissioning in repair of XLPE insulated, screened PVC bedded galvanised steel strip or wire armoured electric power cables (heavy duty) with aluminium conductor 1100 volts grade 95 Sqmm 3.5 Core and including taking down old unsv cable complete all as specified and directed by Engr-in-charge.
26Supply, lay, test and commissioning in repair of XLPE insulated, screened PVC bedded galvanised steel strip or wire armoured electric power cables (heavy duty) with aluminium conductor 1100 volts grade 70 Sqmm 3.5 Core and including taking down old unsv cable complete all as specified and directed by Engr-in-charge.
27Supply, lay, test and commissioning in repair of XLPE insulated, screened PVC bedded galvanised steel strip or wire armoured electric power cables (heavy duty) with aluminium conductor 1100 volts grade 50 Sqmm 3.5 Core complete and including taking down old unsv cable complete complete all as specified and directed by Engr-in-charge.
28Supply, lay, test and commissioning in repair of XLPE insulated, screened PVC bedded galvanised steel strip or wire armoured electric power cables (heavy duty) with aluminium conductor 1100 volts grade 25 Sqmm 4 Core compelte and including taking down old unsv cable complete all as specified and directed by Engr-in-charge.
29Supply, lay, test and commissioning in repair of XLPE insulated, screened PVC bedded galvanised steel strip or wire armoured electric power cables (heavy duty) with aluminium conductor 1100 volts grade 16 Sqmm 4 Core complete and including taking down old unsv cable complete all as specified and directed by Engr-in-charge.
30Supply, laying and Jointing in repair of 50mm X 38 mm outer dia and inner dia , HDPE double walled corrugated (DWC) pipe conforming to IS-16205 with antirodent and non flame propogating properties of approved colour including necessay fittings like bend, tee, elbow,socket etc. for cable protection complete all as specified and as directed.Note :- Joints are designed to be watertight and moisture proof.
31All as per item No. 30 here in above but size 75mm X 61 mm outer dia and inner dia
32All as per item No. 30 here in above but size 90 mm X 76 mm outer dia and inner dia
33All as per item No. 30 here in above but size 110 mm X 93 mm outer dia and inner dia
34M &L in repair steel tubular swaged poles and complete with cast iron / M.S base plate, finial taper plug, bolts, nuts & screws as specified type 410 SP-55 (11 mtrs long) including painting with two coats of aluminium paint over a coat of red oxide metal primer complete all as specified and directed by Engr-in-Charge. The pole shall conform to IS 2713:1980 and each component pipe shall be ISI marked and conform to IS 1161. complete all as specified and directed by Engr -in- charge.
35Dismantling & taking down ACSR conductor, of any size, after taking necessary shut down, for 11 KV HT OH line, by loosening the binding wires, jumpers etc. for replacement of insulator / cross arms etc. complete all as specified and as directed Note: Insulator/Cross arms will be paid separately
36Supply fabricate, fixing structural mild steel RS joist, channel angle iron, flate iron and brackets etc for fabrication of cross arms, bracing supports clamps including D clapms, eye hook and back plate etc fabricated from structural steel section inclduing nuts, bolts,washers, welding (Cold and Hot) drilling holes for bolts, bend to any shape or size as indicated and directed, inclusive of one primer coat and two coats of aluminium paint after preparation of surfaces complete including taking down old materials all as specified and directed by Engineer-in-Charge.
37S&F ACSR conductor of size, as required at site, duly binded with insulators, jumpers etc.(fixed on poles) complete all as specified and as directed.
38S&F in replacement of pin type, porcelain, vitreous, white, brown or green insulator including one galvanised mild steel spindle, two galvanised iron washers and one galvanised iron nut, 150mm height, 150mm dia for 11000 volts grade complete all as specified & directed by Engineer-in-charge.
39S&F in replacement of disc type insulator, porcelain, vitreous with hardware, 145mm high and 255mm dia ball and socket type, white, brown or green, single disc assembly for 11000 volts grade complete all as specified & directed by Engineer-in-charge.
40Supply, Jointing and testing in repair outdoor type cable termination heat shrinkable joint kit 11 KV Unearthed grade suitable for size 95 Sqmm to 120Sqmm 3 core 11 KV under ground XLPE cable complete and including taking down unsv joint complete all as directed by Engineer-in-Charge.
41Supply, Jointing and testing in repair indoor type cable termination cold shrinkable joint kit 11 KV Unearthed grade suitable for size 95 Sqmm to 120Sqmm 3 core 11 KV under ground XLPE cable complete and including taking down unsv joint complete all as directed by Engineer-in-Charge.
42S&F GI pipe light grade of dia 80 mm laying in road and along with poles for cable protection complete including taking down old unsv pipe all as directed by Engineer-in-charge.
43S&F GI pipe light grade of dia 50 mm laying in road and along with poles for cable protection complete including taking down old unsv pipe all as directed by Engr-in-Charge..
44M&L for Servicing the 11 KV GOD by cleaning the contact, disc/ pin insulator with CTC and applying the petroleum jelly at the contact point/ down rod links for smooth operation including replacing the rusted/ corroded bolts & nuts and defective insulator of GOD as required complete all as directed by Engineer - in - Charge.Note :- Insulator & other connected items shall be measured and paid under relevant items of this schedule.
45Supply Male/ Moving contact for 11 KV GOD 200 Amps capacity
46Supply Female/ Fixed contact for 11 KV GOD 200 Amps capacity
47Material and labour in repair for switch air break gang operated triple pole mechanically operated, mounted on HT insulators (12 Insulators Vertical type operated) and MS galvanized steel frame with operating mechanism worked from ground level including operating rod for current rating up to 200 Amps 11000 volts complete with locking arrangement MS clamps, bolts and nuts and washers etc also including drop out expulsion type of fuses with fuse barrels of required capacity to suit load at site including two coats of aluminum paint over a coat of red oxide primer on MS work and including taking down old switch air break gang operated complete all as specified.
48Material and labour in repair for switch air break gang operated triple pole mechanically operated, mounted on HT insulators (09 Insulators Vertical type operated) and MS galvanized steel frame with operating mechanism worked from ground level including operating rod for current rating up to 100 Amps 11000 volts complete with locking arrangement MS clamps, bolts and nuts and washers etc also including drop out expulsion type of fuses with fuse barrels of required capacity to suit load at site including two coats of aluminum paint over a coat of red oxide primer on MS work and including taking down old switch air break gang operated complete all as specified.
49Taking down old unsv existing APFC panel of any type and size and Supply, installation, commissioning and testing of pedestal double door outdoor type, 440volts 8 stages of relay , AC, LT, APFC panel of 50 KVAr capacity, factory fabricated, made out of 3.15mm CRCA sheet, CPRI approved, duly wiring with copper flexible wire and the APFC panel shall be mounted on 50x50x6mm angle iron stand of height 45cm above ground and 45 cm embeded in ground on suitable PCC foundations. Computer cut shelf adhesive vinyl danger notice plate having conventional symbol of bone & skull be provided complete of suitable rating for power control and the APFCPanel shall be dully powder coated including the following :- (A) Incoming ;-(i) MCCB, 415 volts, 4 pole, 125 Amps, 25 kA adjustable type - 01 Nos.(ii) Digital Ammeter with built - in - selector switch Aux Supply 230 Volts, AC - 01 Nos.(iii) Digital Voltmeter with built in selector switch Aux Supply 230 Volts, AC-01 Nos.(iv) LED indication lamp 230 Volts, AC 22.5mm dia RYB-03 Nos.(v) MCB 2 Amp, Single Pole-03 Nos.(vi) Microprocessor APFC relay with single CT sensing 8 stages auxilary supply 230volts, AC - 01 Nos.(vii) Aluminium busbar 20x10mm, TPN - 01 Set.(viii) Auto/Manual Switch - 01 Nos.(B) Outgoing ;-(i) Capacitor 10 KVAr ultra heavy duty 440V cylindrical - 03 Nos.(ii) Capacitor 5 KVAr ultra heavy duty 440V cylindrical - 03 Nos(iii) Capacitor 3 KVAr ultra heavy duty 440V cylindrical - 01 Nos(iv) Capacitor 2 KVAr ultra heavy duty 440V cylindrical - 01 Nos(vi) MCB Triple pole 63 Amps, 10 kA, 'C' sries - 03 Nos(vii) MCB Triple pole 40 Amps, 10 kA, 'C' sries - 03 Nos Please Enable Macros to View BoQ information
50Taking down old unsv existing APFC panel of any type and size and Supply, installation, commissioning and testing of pedestal double door outdoor type, 440volts 8 stages of relay , AC, LT, APFC panel of 50 KVAr capacity, factory fabricated, made out of 3.15mm CRCA sheet, CPRI approved, duly wiring with copper flexible wire and the APFC panel shall be mounted on 50x50x6mm angle iron stand of height 45cm above ground and 45 cm embeded in ground on suitable PCC foundations. Computer cut shelf adhesive vinyl danger notice plate having conventional symbol of bone & skull be provided complete of suitable rating for power control and the APFCPanel shall be dully powder coated including the following :- (A) Incoming ;-(i) MCCB, 415 volts, 4 pole, 125 Amps, 25 kA adjustable type - 01 Nos.(ii) Digital Ammeter with built - in - selector switch Aux Supply 230 Volts, AC - 01 Nos.(iii) Digital Voltmeter with built in selector switch Aux Supply 230 Volts, AC-01 Nos.(iv) LED indication lamp 230 Volts, AC 22.5mm dia RYB-03 Nos.(v) MCB 2 Amp, Single Pole-03 Nos.(vi) Microprocessor APFC relay with single CT sensing 8 stages auxilary supply 230volts, AC - 01 Nos.(vii) Aluminium busbar 20x10mm, TPN - 01 Set.(viii) Auto/Manual Switch - 01 Nos.(B) Outgoing ;-(i) Capacitor 10 KVAr ultra heavy duty 440V cylindrical - 03 Nos.(ii) Capacitor 5 KVAr ultra heavy duty 440V cylindrical - 03 Nos(iii) Capacitor 3 KVAr ultra heavy duty 440V cylindrical - 01 Nos(iv) Capacitor 2 KVAr ultra heavy duty 440V cylindrical - 01 Nos(vi) MCB Triple pole 63 Amps, 10 kA, 'C' sries - 03 Nos(vii) MCB Triple pole 40 Amps, 10 kA, 'C' sries - 03 Nos Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 56691890
AUTHORITY Statutory Bodies & Commissions/Committees
TENDER VALUE 40 Lakhs
LAST DATE 25-08-2026
Authority
Authority Name Military Engineer Services
Work Description Tender for Maintenance And Repairs To Distribution Transformers, Apfc Panels Voltage Stabilizers And Connected Lt Network For Ascon Nodes, Ramgarh & Dabla Under Ge (A) Jaisalmer.
Basic Detail
Tender No 84454/C/E8
Bidding Type Tender
Location
City Jaisalmer
State Rajasthan
Key Dates
Publish Date 28 Jul 2026
Submission Date 25 Aug 2026
Open Date 27 Aug 2026
Finance
Tender Value 40 Lakhs
Tender Fee 500
EMD 80000
Exemption Available
Document List
BOQ_875100.xls
f17bfaad-b9b8-413d-b1a7-bd0348d98b4f.html
Tender.pdf
Tendernotice_1.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Jul 28, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Aug 25, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 27 days
Aug 27, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 29 days

Tender Documents

Download All (ZIP) ↓
xls

BOQ_875100.xls

html

f17bfaad-b9b8-413d-b1a7-bd0348d98b4f.html

pdf

Tender.pdf

pdf

Tendernotice_1.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail
Loading tenders