Defence Statutory Bodies & Commissions/Committees Closing in 19 days TDR #56691889

Tender For Repair / Maintenance Of B/R & E/M Items & Redressal Of Day To Day B/R & E/M Compliant In Md & Otm Accn Of Dgqa In The Aor Of Ge (North) Bangalore

Issued by Statutory Bodies & Commissions/Committees · Bengaluru Urban, Karnataka
Tender Value
45 Lakhs
Estimated cost
Bid Submission
18 Aug 2026
19 days left
EMD
90000
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Bengaluru Urban → Karnataka
EMD Exemption
Available
Quantity
Not Available

Project Description

Tender for Repair / Maintenance Of B/R & E/M Items & Redressal Of Day To Day B/R & E/M Compliant In Md & Otm Accn Of Dgqa In The Aor Of Ge (North) Bangalore

BOQ

Name of Work:- REPAIR / MAINT OF B/R & E/M ITEMS & REDRESSAL OF DAY TO DAY B/R & E/M COMPLIANT IN MD & OTM ACCN OF DGQA IN THE AOR OF GE (NORTH) BANGALORE
Sl. No. Item Description
1Taking down shutters of any description exc 1 Sqm but not exc 2 Sqm and Re-fixing in same opening complete all as specified and directed
2Resecuring or easing & adjusting without taking down shutters of any description exc 1 sqm but n.exc 2 sqm each complete all as specified and directed
3Taking down chowkhat (without taking of shutter from the frame) not exc 1.5 sqm each including making good the disturbed surface in PCC 1:2:4 type B0 or CM 1:3 all as specified and directed
4All as per Item No 3 above, but exc 1.50 sqm and not exc 4.00 sqm each
5Taking down shutters of any description exc 1 Sqm but not exc 2 Sqm each all as specified and as directed
6Solid PVC door frame (Single rebated) of size 60 mm x 30 mm made out of solid foam with homogenious fine cellular structure having smooth outer integral skin with suitable metal stiffner and fixed with 100x8 sheet metal CSK screws complete all as specified and as shown on drawing (Note :- Door frame shall be water proof, termite proof, elegant and should have excellent screws holding strength to fix hinges and hold doors properly for a long life) complete all as specified and directed
7M & L for Factory Made Solid PVC Moulded Door Shutter, 28 to 30mm thick (stiles), with 2, 4, or 6 raised panel design with 2mm thick Moulded PVC Sheet on the front face & 2mm plain colour PVC sheet on back face, supplying & fixing in frame at site as per specification & drawing with wood free EPS .
8M & L for powder coated (minimum thickness of powder coating 50 micron) aluminium frame for doors, windows, ventilators with one or more rebates including joining cleat for fixing etc. complete all as specified )
9M & L Powder coated aluminium (minimum thickness of powder coating 50 micron) for shutters of doors, windows & ventilators including providing and fixing hinges/ pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber/neoprene gasket required (Fittings shall be paid for separately) with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS:1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing/ paneling, C.P. brass/ stainless steel screws all complete as per architectural drawings and the directions of Engineer-in-charge. Note: Supply & fixing of 4 mm thick sheet glass or wire mesh be measured and paid separately.
10S&F Anodised aluminum powder coated (of any shade/colour as approved by GE ) ventilators with adjustable 4mm thick figured glass louvers, fixed in half portion, without sash bars, aluminum section weighing 0.55 kg/m including necessary jointing cleats, glazing clips, rubber packing, anodised aluminum snap beading, screws, including stainless steel wire cloth 0.36 nominal dia of wire and average width of aperture 1.18mm including complete etc all as specified and directed by the Engineer-in-charge (Size of Ventilators = 500x850 mm)
11S&F power coated (minimum coating 50 micron) aluminium Deco grill of No DG-104 as per drg No TD-531 sheet 1/1, (minium thickness 6 mm) shall be reveted to panel of frame using U channel, complete all as directed.
12M & L for Framed work such as grills, gratings, etc.. with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks and similar work conforming to Fe.290.Gde-E-165
13Supply & fix Sheet glass 4mm thick ordinary quality and glazing with oil putty or in wooden /steel /aluminium /rubber beading in square not exceeding 0.5 Sqm in each pane and all as specified.
14Supply & fix Sheet glass 4mm thick ordinary quality and glazing with oil or in wooden /steel /aluminium /rubber beadingputty in square exceeding 0.5 Sqm in each pane and all as specified.
15Supply & fix stainless steel wire cloth 0.36mm nominal dia and average width of aperture 1.40mm and fixed with tinned tack or galvanized wire staple all as directed fixed.
16Dismantling of structural steel work including doors,gates but excluding framed truss etc all as specified.
17S&F framed work as in doors or gates of angle or other sections with gusset plates, rails braces, etc complete drilled for fixing of steel sheeting or other covering, doors etc, to be prepared for hanging or sliding with and including either hooks and hinges or steel hanging door fittings(exclusive of steel sheeting or other covering, running rails and guides) and hanging ; also fastening and fixing complete including painted with one shop coat of zinc chromate primer paint (including preparation of surface) at contractors workshop/factory before fabrication complete all as specied and directed.
18S & F of 1.25 mm thick Mild steel, plain, black sheet in wall cladding, steel gates and similar work, cut to size, holes punched; including round headed screws, clout nails or rivets and fixed to wood or steel framing with plain 40 mm lap joints with riveted or welded seams, including bending or turning up, mitred angles, etc. as required
19M & L applying two coats of synthetic enamel paint over a coat of red oxide primer on steel surfaces over 10 cm width or girth including preparation of new steel surfaces
20S & F Butt hinges stainless steel 100mm long and fixed to door frame and shutter duly welded/screwed complete all as specified and as directed
21S&F Aluminium anodised tower bolt 150mm long of extruded section etc complete all as specified and as directed .
22S&F 125 mm long aluminium handle, cast type, anodised etc complete all as specified and as directed
23M & L 4 mm thick figured glass, pin head type and glazing with oil putty/wooden or steel beading in squares n.exc 0.5 Sqm in each pane all as specified and as directed. incl Hacking out old broken glass of any thickness, size, quality or description from metal frame including punching or drilling out old glazing pins/spring clips etc complete all as specified and as directed.
24M&L for 3mm thick Sheet glass, ordinary quality and glazing with oil putty / wooden or steel beading in squares .exc 0.5 sqm in each pane all as specified and as directed. incl Hacking out old broken glass of any thickness, size, quality or description from metal frame including punching or drilling out old glazing pins/spring clips etc complete all as specified and as directed.
25M&L for 3mm thick Sheet glass, ordinary quality and glazing with oil putty / wooden or steel beading in squares n.exc 0.5 sqm in each pane all as specified and as directed. incl Hacking out old broken glass of any thickness, size, quality or description from metal frame including punching or drilling out old glazing pins/spring clips etc complete all as specified and as directed.
26M & L for Running welding in repairs thickness of metal to be welded N exc 6 mm thick complete all as specified and as directed.
27S & F in repairs Aluminium anodised barrel towel bolts of extruded section of length 150 mm all as specified and as directed.
28S & F in repairs Aluminium anodised barrel towel bolts of extruded section of length 200 mm all as specified and as directed.
29S & F in repairs Aluminium alloy anodised sliding door bolt with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections including taking down old sliding door bolt 300 mm all as specified and as directed.
30S & F in repairs extruded alloy handles fabricated type anodised of size 125 mm all as specified and as directed.
31S & F in repairs extruded alloy handles fabricated type anodised of size 150 mm all as specified and as directed.
32S&F in repairs Butt hinges medium weight cold rolled mild steel of size of hinges 100mm
33S & F in repairs 140 mm floor door stopper of aluminium alloy powder coated, with hard down steel spring all as specified and as directed.
34S&F in repair Rubber door buffer 125mm size fixed with brass screws complete all as specified and directed
35S&F in repair mild steel 300mm, ordinary rat tail rod pattern springs,including roller and roller plate complete all as specified and as directed.
36S&F in repairs door closer hydraulically regulated designation No.3, universal type, suitable for door shutters of 851 to 1000 mm in width and of weight between 61 to 80 Kg of aluminium (extruded section)body in repairs complete all as specified and as directed.
37S & F in repairs 18/19mm thick Prelaminated particle board, interior grade, prelaminated one side with decorative choice lamination & other side balancing white lamination, fixed with screws to timber frame work,alround 6mm th teak fillets fixed in kitchen Cabinet or cupboards all as specified.
38M&L for Plain fillets square, rectangular or triangular in section clean sawn , secured with nails or brads of second class hard wood fixed to cupboard shutter including taking down old fillets exc 6 & n exc 13 sqcm cross section area all as specified and directed.
39S&F of Nickle plated ebco Hinges suitable for 16 to 19 mm cabinet door
40S&F 100 mm size hasp and staple, safety type, aluminium anodized with mild steel hinge pin including bolt to hinge plate and fixed with screws.
41S&F Magnet door catcher made of stainless steel complete all as specified and directed.
42S & F 40 mm dia cupboard knobs fixed with nut, screw and washer of Brass,polished complete all as specified and as directed.
43S & F in repairs Hasp and staple safety type of size 100 mm of aluminium anodized all as specified and as directed.
44S & F in repairs 40 mm dia cupboard knobs fixed with nut, screw and washer of Brass, polished complete all as specified and as directed.
45S&F in repairs Magntet door catcher made of stainless steel complete all as specified and directed.
46S&F in repairs stainless steel decorative curtain rod of 20 mm bore with wood finishes (weight not less 200 gms per running meter) incl fancy finale caps cap etc complete all as specified and as directed.
47S&F in repair Bracket for curtain rod of dia 20 mm dia made out of SS Flat not less than 20 mm wide 1.50 mm thick and overall length not less than 160 mm fixed with screws min 2 Nos with Rawl Plug of size not less than 50 mm long incl wooden base etc complete etc complete all as specified and as directed.
48M & L for 20 mm thick Granite (of any type) work (table rubbed and polished) in steps, jambs, pillars, window-cills, cooking platforms and like in cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite ,including cutting and polishing laid on 15 mm thick screed bed in CM 1:4 set and jointed including dismantling of old stone slabs laid bedded and pointed in any mortar complete all as specified.
49M & L for Providing edge moulding to 18-20mm thick granite stone any description of counters vanities etc. including machine polishing to edge to give high gloss finish etc. complete .
50S & F in repair kitchen sink with drainage board made of stainless steel 1mm thick kitchen or laborotry with plugs, washers and wastes including bedding in mortar on to dwarf wall or including fixing cantilever brackets and connecting union pipes overall size 915x460mm bowl size 410x330x160mm complete.
51S&F in repair sinks made of stainless steel lmm thick kitchen or laboratory with plugs, washers and wastes; including bedding in cement mortar on to dwarf wall or including fixing cantilever brackets and connecting union to pipe, overall size 495mm x 420mm bowl size 410mm x 330mm x 160mm complete.
52S&F in repairs stainless steel plate rack of 0.63mm thick sheet, size 800mm x 600mm complete all as specified and as directed
53Opening of air lock/blockage in GI / CPVC pipe line of any dia from outlet of water tank to all internal GI/CPVC pipes / fittings to smooth flow of water from bib taps / showers / WHB pillar tap / stop valves / mixers complete by air prssure /water gravity pressure all as specified and directed.
54S&F in repairs brass spindle of any type with nylon washer and removing leakage of water of any bib tap / stop valve / angle / Pillar cock / wall / sink mixer suitable for 15mm bore pipe complete all as specified.
55S&F in repairs brass spindle of any type with nylon washer and removing leakage of water of any concealed stop valve suitable for 15mm bore pipe complete all as specified.
56S&F in repairs brass elbow suitable for CPVC pipe 20mm outer dia complete all as specified and directed.
57S&F in repairs brass elbow (3/4 X ½) suitable for CPVC pipe 20mm outer dia complete all as specified and directed.
58S&F in repairs Brass Tee suitable for CPVC pipe 20mm outer dia complete all as specified and directed.
59S&F in repairs Brass Tee suitable for CPVC pipe 25mm outer dia complete all as specified and directed.
60S&F in repairs Male Brass Threaded Adaptor (MTA/ MBTA) suitable for CPVC pipe 20mm outer dia complete all as specified and directed.
61S&F in repairs Male Brass Threaded Adaptor (MTA/ MBTA) suitable for CPVC pipe 25mm outer dia complete all as specified and directed.
62S&F in repairs Female Brass Threaded Adaptor (MTA/ MBTA) suitable for CPVC pipe 20mm outer dia complete all as specified and directed.
63S&F in repairs Female Brass Threaded Adaptor (MTA/ MBTA) suitable for CPVC pipe 25mm outer dia complete all as specified and directed.
64S&F in repairs CPVC Tank Adoptor suitable for CPVC pipe 20mm outer dia complete all as specified and directed.
65S&F in repairs CPVC Tank Adoptor suitable for CPVC pipe 25mm outer dia complete all as specified and directed.
66S&F in repairs CPVC Union suitable for CPVC pipe 20mm outer dia complete all as specified and directed.
67S&F in repairs CPVC Union suitable for CPVC pipe 25mm outer dia complete all as specified and directed.
68S&F in repairs CPVC tank nipple 20mm dia suitable for HDPE water tank. (Minimum weight 20mm- 45gms )
69S&F in repairs CPVC tank nipple 25mm dia suitable for HDPE water tank. (Minimum weight 25mm- 65gms)
70S&F in repairs 15mm PTMT extension Nipple. (Minimum weight 15mm-18 gms)
71S&F in repairs 15mm PTMT flange, (Minimum weight 15mm-5gms)
72S&F in repairs 20mm CPVC gate valves, with lever , screwed both ends for iron pipe and fixed
73S&F in repairs 25mm CPVC gate valves, with lever , screwed both ends for iron pipe and fixed
74S&F in repair Vitreous China wash basin, white, flat back, size 550x400mm including 32 mm dia brass waste coupling ,chromium plated fancy type pillar taps, waste pipe, 600 mm long PVC connection & brackets including cutting for and pinning in ends of brackets or erecting stand but exclusive of fixing & supply and waste pipe.
75S&F in repair Vitreous china wash down water closet pan ( pedestral Pattern) white, (Including flushing cistern and flush pipe ) , including connection to drain & or out going pipe ) and to flushing pipe, anti syphonage pipe, seat and cover for pedestral pan including PVC flushing cistern and 450 mm long PVC connection etc.
76Vitreous China squatting pan, ‘Orissa’ pattern, size 580 x 440 mm white, with integral foot rests including PVC SWR P trap 10 litr PVC flushing cistern,600 mm long PVC connections connecting to flush pipe and to anti syphonage pipe, etc. complete including making good to floor, fixed in repairs complete all as specified and directed.
77S&F in repairs Vitreous China bowl urinal flat back, size of 465 x 355 x 265 mm white (minimum), with grating and union for discharge pipe (excluding flushing cistern, flush pipe ) but including Concussive push button taps of cast copper alloy, screwed for iron pipe, PTMT waste coupling suitable for urinals, (Minimum weight 32mm-45gms) urinal spreader and 450 mm long PVC connection and PVC urinal waste pipe complete all as specified and as directed.
78S&F in repairs 10 ltrs capacity PVC valveless syphonic action flushing cistern low level with inlet ball valve, flush pipe of polythelene of low or high density or PVC 32mm dia comlplete all as specified and directed.
79S&F in repairs syphone kit including ball valve, handle etc for low level flushing cistern complete all as specified and directed.
80Supply & laying 20 mm outer dia CPVC pipes SDR 11 ( Plain CPVC SDR 11 fittings on walls/ceiling or laying in floors including all fittings and specials including taking down 15 mm GI tubing and connections complete all as specified.
81Supply & laying 25 mm outer dia CPVC pipes SDR 11 ( Plain CPVC SDR 11 fittings on walls/ceiling or laying in floors including all fittings and specials including taking down 20 mm GI tubing and connections complete all as specified.
82S&F in repairs Brass CP wall mixer for mixing hot and cold water screwed down for iron pipe and fixed complete all as specified and directed.
83S&F wash basin Brass CP mixer for mixing hot & cold water screwed down for iron pipe 15 mm and fixed in repairs
84S&F in repairs 15mm bore CP pillar taps, fancy type, cast copper alloy with capstan heads, screwed down high pressure, with or without lettered `Hot' or `Cold' with long screwd shanks and fly-nuts, screwed for iron pipe and fixed complete all as specified and directed.
85S&F 15mm stop valves/ angle valves cast copper alloy, screwed down, high pressure, fancy type,chromium plated screwed both ends for iron pipe or for unions and fixed in repairs.
86S&F two way bib cock with angle valve combination brass chromium plated, fixed in repairs.
87S&F 15mm stop valves cast copper alloy, screwed down, high pressure, fancy type, chromium plated with long shank and cup (concealed type) screwed both ends for iron pipe or for unions and fixed in repairs.
88S & F chromium plated long body bib tap 15mm dia with CP flange as fixed in repair all as specified and as directed.
89S & F chromium plated swan neck adjustable & rotational type kitchen sink tap 15mm dia with CP flange as fixed in repair all as specified and as directed.
90S&F concussive push button taps of cast copper alloy, for 15mm dia of pipe, screwed for iron pipe and fixed in repairs.
91S & F in repairs Health faucet (ABS Body) mild steel chromium plated suitable for 15 mm dia pipe with 1.25 metre long flexible tube and ABS wall hook including making connections and fixed in position including taking down old complete in all respect as specified.
92S & F in repairs Towel rail stainless steel glossy finish,D type 20 mm dia and 600 mm long complete all as specified and as directed.
93S & F in repairs Towel ring stainless steel glossy finish,circular type minimum 5mm thick and 15 cm dia complete all as specified and as directed.
94S&F125mm dia brass chromium plated shower rose with swivel joints fixed in repairs .
95S&F in repairs Soap dish chromium plated brass all as fixed in wall as per manufacturers instruction.
96S&F in repairs Toilet paper holder with flat recessed type stainless steel Complete all as specified and directed.
97S & F in repairs 600mmx450mm bevelled edge mirror of selected quality glass, mounted on PVC sheet and fixed to wooden plugs with chromium plated brass screws and cup washers complete all as specified
98S&F in repairs PVC Mirror cabinet of size 400x500 mm complete all as specified and as directed.
99S & F in repair PVC connection (Suitable for Cold Water Supply) 15 mm size with PTMT nuts of length 450 mm, all as specified and as directed.
100S & F in repair PVC connection (Suitable for HOT Water Supply) 15 mm size with PTMT nuts of length 450 mm, all as specified and as directed.
101M&L 32 mm dia waste fittings, brass, chromium plated for sinks, basins, etc with long screwed shanks and flynuts, flange end fixed in repair complete all as specified and as directed
102M&L 75 mm dia waste fittings, brass, chromium plated for sinks etc with long screwed shanks and flynuts, flange end fixed in repair complete all as specified and as directed
103M&L in repairs 32mm dia, 800mm long corrugated waste pipe complete all as specified and as directed.
104S&F in repairs PVC urinal waste pipe 32mm dia 800mm long, complete all as specified and directed
105S&F in repair 15mm dia Bib tap PTMT fancy type any colour screwed, for iron pipe and fixed
106S&F in repair 15mm dia Pillar tap PTMT fancy type any colour screwed, for iron pipe and fixed
107S&F in repair 15mm dia angle stop valve of PTMT any colour pressed screwed, for iron pipe and fixed
108S & F PVC sintex tank cover suitable for 500/1000 litre capacity water tank complete as in repairs
109S&F in repair plastic water closet seat cover for western & indo western pedestal pan closed pattern with flat bottom, and cover and mild steel chromimium plated or aluminised hinging device fixed complete all as specified and directed.
110Disconnecting to existing PVC tanks , setting aside (for lowering down if required) for repairs , if hoisting if required reconnecting and refixing in position exc 250 n exc. 500 ltr including cleaning of overhead tank including removing the sludge washing down with detergent powder & writing the date of cleaning with paint complete all as specified and as directed .
111Disconnecting to existing PVC tanks , setting aside (for lowering down if required) for repairs , if hoisting if required reconnecting and refixing in position exc 500 n exc. 1000 ltr including cleaning of overhead tank including removing the sludge washing down with detergent powder & writing the date of cleaning with paint complete all as specified and as directed .
112M & L for 500 litres capacity rotational moulded, triple layer polythene water storage tanks (cylindrical vertical with closed top) hoisting and fixed in position on roofs including 20 mm dia ball valve and fittings including dismantling existing water storage tank, complete all as specified.
113M & L for 1000 litres capacity rotational moulded, triple layer polythene water storage tanks (cylindrical vertical with closed top) hoisting and fixed in position on roofs including 25 mm dia ball valve and fittings including dismantling existing water storage tank, complete all as specified.
114S & F in repairs 25 mm dia of bore ball float valves high pressure of PTMT with epoxy coated aluminium rod & high density plastic ball screwed for iron pipe complete all as specified and as directed [Minimum weight for 20 mm – 210 gms] .
115S & F in repairs 20 mm dia of bore ball float valves high pressure of PTMT with epoxy coated aluminium rod & high density plastic ball screwed for iron pipe complete all as specified and as directed [Minimum weight for 20 mm – 210 gms] .
116Dismantling of floor, hearth or wall tilling incl cement mortar bedding (but not backing) and removing rubbish off from premises.
117Demolition of cement concrete and paving not exc 15 cm thick (below or above ground level) complete all as specified and as directed.
118M&L Non Skid ceramic tiles 7 to 8 mm thick (square/ rectangular) area of each tile exceeding 0.06 Sqm but not exceeding 0.11 Sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match over and incl Screed bed or bedding layer of mortar 15 mm thick in CM 1:4 for laying floor finishes all as specified and as directed.
119M&L Non Skid Virified Ceramic tiles 10 mm thick (square/ rectangular) polished, area of each tiles not exceeding 0.36 sq, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match over and incl Screed bed or bedding layer of mortar 15 mm thick in CM 1:4 for laying floor finishes all as specified and as directed.
120M & L Glazed ceramic tiles in vertical surfaces 350 x 250x 7 mm/ 450 x 350 x 7 mm/ 300x450x7 mm thick set and jointed in neat cement slurry and pointed in white or coloured cement to match the surface over & incl 10mm thick in screed CM 1:4 on brick work or concrete surfaces to receive wall tiles all as specified and as directed.
121M&L providing cement concrete type E2 1:5:10 (40mm graded stone aggregate) in foundations, filling and mass concrete for sunken floor including Demolition of cement concrete exc 15 cm thickness but above ground floors including removal of debris from MD Land complete all as specified and as directed.
122Demolition of brick/stone/boulder /precast concrete articles and precast concrete block built in cement mortar etc complete all as specified.
123M&L for Pre-cast cement concrete block masonry, type C1 1:3:6(using 20mm graded aggregate) in CM 1:6 with solid blocks,exc 10cm in width and setting in mortar, complete.
124Taking down cement plaster of any description including racking out joints, hacking for key and disposal of debris to out side MD land all as specified and as directed.
125M&L for rendering 15 mm thick on fairfaces of brick work or concrete surfaces in cement mortar 1:6 finished plastered surface even and smooth without using extra cement
126M&L for rendering 15 mm thick on other than fair faces of brick work or concrete surfaces in cement mortar 1:4 with WPC, finished plastered surface even and smooth without using extra cement Note :- WPC will be measured and paid separately
127Supply only liquid water proofing compound
128M&L for rendering 5 mm thick on ceiling /RCC surfaces in cement mortar 1:3, finished plastered surface even and smooth without using extra cement
129M&L Preparation of newly plastered surfaces and applying two coat of oil bound distemper over a coat of alkali resistent primer over two coats of wall care putty complete all as specified and directed
130M & L preparation of newly plastered surface of wall and applying two coats of cement base paint complete all as specified and as directed.
131M & L for preparing newly plastered ceiling surfaces and applying three coat of white wash complete all as specified & as directed.
132S & F in repair 110 mm dia bore PVC (SWR) pipes single socketed in any length with rubber ring joints fixed to walls including necessary fittings all as specified and as directed.
133S & F in repair 75 mm dia bore PVC (SWR) pipes single socketed in any length with rubber ring joints fixed to walls including necessary fittings all as specified and as directed.
134S & F in repair 75mm dia PVC(SWR) floor trap,plain with grating including jointing with slvent cement all as specified and as directed.
135S & F in repair grating doom 100 mm dia of PTMT complete all as specified and as directed .
136S&F in repair 110mm dia PVC (SWR) Bends with access door of any radious
137S&F in repair 75mm dia PVC (SWR) Bends with access door of any radious
138S&F in repair 110mm dia PVC (SWR) junction single (single T) equal or unequal with access door
139S&F in repair 75mm dia PVC (SWR) junction single (single T) equal or unequal with access door
140S&F in repair 110mm dia PVC(SWR) brach piece, single (single Y) equal or un equal with access door
141S&F in repair 75mm dia PVC(SWR) brach piece, single (single Y) equal or un equal with access door
142S&F in repair 110mm dia PVC(SWR) brach piece, (double Y) equal or un equal with access door
143S&F in repair 75mm dia PVC(SWR) brach piece, (double Y) equal or un equal with access door
144S&F in repair 110mm dia PVC(SWR) vent cowl
145S&F in repair 75mm dia PVC(SWR) vent cowl
146M & L for Complete removal of existing treatment on wall surfaces chajjas etc of any description including brooming down with steel wire brushing, scrapping down smoke soot's, moulds, moss and efflorescence, salts, trading oil and greasy spots etc and applying two coats of Anti fungal weather proof grade exterior acrylic emulsion paint of approved tint (Apex Ultima or equivalent brand as specified in CA) over a coat of weather proof primer including filling the minor racks etc with crack filling material all as per manufacturers instructions complete all as specified and as directed.
147Preparation of old decorated surfaces and applying one coat of white wash on ceilings including in narrow widths/ bands etc complete all specified and as directed.
148Preparation of old painted surface and applying one coat of synthetic enamel paint on steel and iron surfaces over 10cm width or girth all as specified and as directed.
149Preparation of old painted surfaces and applying one coat of synthetic enamel paint on wood and wood based surfaces over 10cm width or girth all as specified and as directed.
150Preparation of old decorated surfaces including washing, rubbing down and stopping and applying one coat of oil emulsion distemper on walls all as specified and directed.
151Preparation of old decorated surfaces including washing, rubbing down and stopping and applying two coats of oil emulsion distemper on walls including necessary putty all as specified and directed.
152Taking down carefully aluminium/ copper wiring/power point wiring (light, fan, socket or power) complete including fittings such as switches ceiling roses, regulators, sockets , light fittings, fans etc and making good the disturbed surface of walls, ceiling etc incl painting with same colour of the back ground complete all as specified and as directed by Engineer-in-Charge.
153Point wiring complete concealed with 1.5 Sqmm single core PVC insulated unsheathed cable 1100 volts grade multi stranded with FRLS copper conductor conforming to IS 694 drawn through and incl non-metalic rigid PVC conduit medium grade ISI marked incl accessories concelaed type wiring incl GI/ MS branded sunken boxes suitable for normal/modular concealed on walls including plastic/heylam laminated sheet top cover 3 mm thick/modular frame and cover of suitable module fixed with cadmium plated iron screws for housing modular/normal type switches, switch socket outlets, fan regulators etc., incl provision of 1.5 Sqmm PVC insulated single core multi stranded copper conductor cable as earth continuity conductor and connecting to common earth dolly, all as specified and as directed.for the following :-One light point controlled by one switch
154All as per item No. 153 above but forOne fan point controlled by one switch / regulator
155All as per item No. 153 above but forOne light point controlled by 2 way switch
156All as per item No. 153 above but forOne 3 pin socket out let 5 Amps on independent board
157All as per item No. 153 above but forOne bell / buzzer point controlled by bell push
158All as per item No. 153 above but forOne 3 pin socket out let 5 A on same board
159All as per item No. 153 above but for concealed wiring drawn through existing PVC conduit.One light point controlled by one switch
160All as per item No. 159 above but forOne fan / Exhaust point controlled by one switch / regulator
161All as per item No. 159 above but forOne light point controlled by 2 way switch
162All as per item No. 159 above but forOne 3 pin socket out let 5 Amps on independent board
163All as per item No. 159 above but forOne bell / buzzer point controlled by bell push
164All as per item No. 159 above but forOne 3 pin socket out let 5 A on same board
165Point wiring complete with 2.5 Sqmm single core PVC insulated unsheathed cable 1100 volts grade multi stranded with FRLS copper conductor conforming to IS 694 drawn through non-metalic existing PVC conduit medium density ISI marked incl accessories surface type run on walls/ ceiling incl MS terminal boxes fabricated with 1.6 mm thick GI/MS sheet surface mounted/ concealed on walls with plastic laminated sheet top cover 3 mm thick fixed with cadmium plated iron screws for housing the switches, switch socket outlets, fan regulators etc., incl provision of 2.5 Sqmm PVC insulated single core multi stranded copper conductor cable as earth continuity conductor and connecting to common earth dolly, all as specified and as directed.
166Point wiring complete with 1.5 Sqmm single core PVC insulated unsheathed cable 1100 volts grade multi stranded with FRLS copper conductor conforming to IS 694 drawn through and incl PVC Casing & Caping ISI marked incl accessories surface type wiring incl 1.6 mm thick GI/MS sunken boxes concealed on walls including laminated sheet top cover 3 mm thick fixed with cadmium plated iron screws for housing the switches, switch socket outlets, fan regulators etc., incl provision of 1.5 Sqmm PVC insulated single core multi stranded copper conductor cable as earth continuity conductor and connecting to common earth dolly, all as specified and as directed.for the following One light point controlled by one switch
167All as per item No. 166 above but forOne fan point controlled by one switch / regulator
168All as per item No. 166 above but forOne light point controlled by 2 way switch
169All as per item No. 166 above but forOne 3 pin socket out let 5 Amps on independent board
170All as per item No. 166 above but forOne bell / buzzer point controlled by bell push
171All as per item No. 166 above but forOne 3 pin socket out let 5 A on same board
172Point wiring complete with 2.5 Sqmm single core PVC insulated unsheathed cable 1100 volts grade multi stranded with FRLS copper conductor conforming to IS 694 drawn through and incl non-metalic PVC conduit medium density ISI marked incl accessories concealed type run on walls/ ceiling incl GI/MS terminal boxes fabricated with 1.6 mm thick MS sheet concealed on walls with plastic laminated sheet top cover 3 mm thick fixed with cadmium plated iron screws for housing the switches, switch socket outlets, fan regulators etc., incl provision of 2.5 Sqmm PVC insulated single core multi stranded copper conductor cable as earth continuity conductor and connecting to common earth dolly, all as specified and as directed.
173Point wiring complete with 2.5 Sqmm single core PVC insulated unsheathed cable 1100 volts grade multi stranded with FRLS copper conductor conforming to IS 694 drawn through and incl PVC casing caping ISI marked incl incl accessories surface type wiring run on walls/ ceiling incl GI/MS terminal boxes fabricated with 1.6 mm thick MS sheet concealed on walls with plastic laminated sheet top cover 3 mm thick fixed with cadmium plated iron screws for housing the switches, switch socket outlets, fan regulators etc., incl provision of 2.5 Sqmm PVC insulated single core multi stranded copper conductor cable as earth continuity conductor and connecting to common earth dolly, all as specified and as directed.Note for Item No 2 to 7 :-(i) The earth wire for the points in the same circuit can be looped from point to point(ii) Earth wire shall be taken inside the conduit(iii) Cost of terminal box is deemed to be included in the item rate quoted for point wiring(iv) Cost of a circuit of any length of cable from DB to any switch/ socket board to be included in point wiring. (v) Cost of cutting chases for conduits and making good to walls, in case of recessed or concealed conduit wiring will be included in unit rate quated .
174M&L for groove cutting in wall/floor and making good of distrubed wall/floor, painting of existing colour all as specified and directed by Engineer -in-Charge.
175S&F in repair LED batten suitable for indoor applications 20 Watts, 4 feet with extruded aluminium housing & integrated LED channel complete with all accessories including taking out old fittings all as specified and directed.
176S&F in repair LED batten suitable for indoor applications 10 Watts, 2 feet with polycarbonate housing & integrated LED channel with white arcylic cover complete with all accessories including taking out old fittings all as specified and directed.
177S&F in repair 2' x 2' Recess mounted LED Luminaire 36 Watts white powder coated CRCA housing with LEDs seamless front frame with flate white high transmission arcylic cover complete with all accessories all including taking out old fittings as specified and directed.
178S&F in repair 2' x 2' Surface mounted LED Luminaire 36 Watts white powder coated CRCA housing with LEDs seamless front frame with flate white high transmission arcylic cover complete with all accessories all including taking out old fittings as specified and directed.
179Supply and fix in repair Slim surface mounted round LED down lighter of 12 watt aluminium die cast body with premium diffuser to ensure glare free & even distribution of light.
180Supply and Fix Modular switch 1 way 6A,1 module
181Supply and fix Modular switch 1 way 16A, 1 module
182Supply and fix Modular switch 2 way 6A,1 module
183Supply and Fix Modular Bell push 6A 1 module
184Supply and fix modular Socket, 6A - 2/3 pin combined 2 module
185Supply and fix modular Socket 6A/16A - 2/3 pin combined 2 module,
186Supply and fix modular type Fan step regulator, 120W - 2 module
187S&F of of Switch piano flush button single pole two way 5 Amps all as specified and as directed.
188S&F of Angle holder PVC/polycarbonate type all as specified and as directed
189S&F of switch piano flush type single pole one way 5 Amps
190S&F of switch socket combination 5 pin 2 in 1, 5 A Flush type all as specified and as directed
191S&F of switch socket combination 2 in 1, 3 pin 5 and 15 Amps flush type universal all as specified and as directed
192S&F of bell push flush type 5A all as specified and as directed .
193S&F in repair of MCB SPN 240 volts 32/40 Amps complete all as specified and as directed
194S&F in repair of MCB single pole 240 volts 10/16/20/32 Amps complete all as specified and as directed
195S&F in repair of MCB TPN 415 volts, 10KA 'C' curve 63 Amps complete all as specified and as directed
196S&F in repair of MCB TPN 415 volts, 10KA 'C' curve 100 Amps complete all as specified and as directed
197S&F in repair of MCB DB SPN 4 way double door type 240 volts with 200 Amps rated busbar as specified and as directed.
198S&F in repair of MCB DB SPN 8 way double door type 240 volts with 200 Amps rated busbar as specified and as directed.
199S&F in repair of MCB DB TPN 4 way with double door type 415 volts with 200 Amps rated busbar for housing MCBs as specified and as directed.
200S&F of ceiling rose, surface bakelite type 65 x 50 mm, 2 to 3 terminals all as specified and as directed
201S&F of stepped type electronic fan regulator flush Switch/socket type all as specified and as directed
202S&F of Ding Dong bell AC 230 volts single pole.
203Removing of old existing and provision of new sub main wiring 1100 volts grade multistranded FRLS copper conductors, two runs of single core 6 Sqmm along with 6 Sqm PVC insulated single core multistranded copper conductor cable as earth continuity conductor run along with PVC conduit all as specified and as directed
204Removing of old existing and provision of new sub main wiring 1100 volts grade multistranded FRLS copper conductors, two runs of single core 4 Sqmm along with 4 Sqm PVC insulated single core multistranded copper conductor cable as earth continuity conductor run along with PVC conduit all as specified and as directed
205Removing of old existing and provision of new sub main wiring 1100 volts grade multistranded FRLS copper conductors, two runs of single core 2.5 Sqmm along with 2.5 Sqm PVC insulated single core multistranded copper conductor cable as earth continuity conductor run along with PVC conduit all as specified and as directed
206M&L for earthing complete with galvanized steel earth plate electrode 60 cm x 60 cm x 6mm thick buried directly in ground vertically to a depth not less than 2.25 mtr below ground level with top edge of earth plate at a depth not less than 1.5 mtr connected to galvanized earth lead wire 4 mm dia as earth lead up to 7.5 mtr long by means of nuts, bolts, thimbles,check nuts and washers etc made of galvanized iron connected to earthing test point all as shown in electrical plate No 3 of SSR Part-I 2010 and as specified or indicated and testing on completion incl earth work and excavation in any type of soil PCC (1:3:6) type C1 chamber, pre cost slab 40mm thick in cement concrete (1:2:4) type B1 with 8 mm dia MS bars reinforced at 10 cm centre to centre both ways incl funnel with watering pipe wire mesh and lugs, incl test point complete all as specified and as directed including dismantaling and taking down old Earthing plates.
207Supply and fixing in repair 30 W LED bldg security light fitting with pressure die cast housing along with prismatic polycarbonate difuser with IP 66 protection including taking out old fittings.
208S&Fin repair of Bracket made out of GI tubing medium grade 25 mm bore , approx length 1.5 m long including MS clamps made out of MS flat iron 25 x 6 mm , nuts, bolts, washers etc and including before fixing applying two coats of aluminum paint over a coat of red oxide primer including removing the old existing GI bracket from bldg complete all as specified and directed.
209S&F in repair Bulk Head Fitting suitable for indoor application of 10 watt, including electrical connecion from ceiling rose with 3 core 1.5 sqmm sheathed wire all as directed.
210S&F in repair Decorative wall light fixture made up of polycabonate suitable for indoor application of 9 watt LED lamp E27 blub holder , modern wall lamp( Metal black Up & down light) including electrical connecion from ceiling rose with 3 core 1.5 sqmm sheathed wire all as directed. Brand- BrightLyt
211S&F in repair LED Bulb suitable for indoor application of 9 watt, to fit in Angle Holder or Decorative wall light fixture all as directed. Make & Model No: Havells Cat part No: ADORE LED PLUS 9 W
212S&F in repair ceiling fans outer body with complete accessories, etc all as specified and as directed
213S&F in repair ceiling fans blade with complete accessories, etc all as specified and as directed
214S&F in repair ceiling fans internal body with winding complete accessories, etc all as specified and as directed
215S&F in repair PVC Fresh air fan MAXIMA DXI G02 IVORY DOM EX FAN of 150mm sweep 1200/1400 RPM with louver. Make Bajaj
216S&F in repair PVC Fresh air fan MAXIMA DXI WHITE DOM EX FAN of 200/225mm sweep 1200/1400 RPM with louver. Make-Bajaj. or CG/Usha/ Orient/Phillips
217S&Fin repair PVC Fresh air fan MAXIMA DXI WHITE DOM EX FAN of 250/300mm sweep 1200/1400 RPM with louver. Make-Bajaj. or CG/Usha/ Orient/Phillips
218S&F in in repair replacement of Single pole & neutral enclosure 20 Amps & 240 V with two pin and earth plug and socket complete with one single pole MCB 20Amps
219Inspection, taking down, dismantling of geysers of any type/capacity, cleaning, descaling, reassembling & reinstallation on the old place incl hydraulic pressure test of container with hand operated hydraulic pump complete, brazing inner tank, internal wiring and reinstallation after necessary repair / replacement of old parts all as specified & as directed. Note : Replacement of old parts shall be measured & paid separately.
220Supply only stainless/Mild steel inner tank of capacity 25 ltrs unit including internally assembly of any size and type complete all as specified & as directed.
221Supply only internal assembly/apparatus rod unit of any size and type of capacity 25 ltrs complete all as specified & as directed.
222Supply only heating element of 2 KW rating triangular/round type as per existing size and type including rubber washers all as specified & as directed.
223Supply only heating element of 2 KW rating Hexagonal spiral/bend type as per existing size and type including rubber washers all as specified & as directed.
224Supply only Thermostat/auto cut off of suitable size and type for 25/50 Ltrs capacity of any size.
225Supply only Indicator lamp red and green type square/round.
226Supply only Safety valve / high pressure valve / NRV of exisitng type ISI marked.
227Supply only PVC insulated Copper cable flexible 3 core of size 40/0.0076 ISI marked.
228Supply only outer cover of geyger for capacity 25 ltrs unit complete with all fitting and fixtures as specified & as directed.
229S&F in repair of exhaust fans outerframe for holding exhaust fan motor upto 225 mm sweep with supporting angle complete all as specified and directed.
230S&F in repair of exhaust fans outerframe for holding exhaust fan motor 300 mm sweep with supporting angle complete all as specified and directed.
231M&L in repair louver of exhaust fan suitable for 300/230 mm sweep complete accessories all as specified and directed
232S&F in repair of exhaust fans motor 300 mm sweep with supporting angle complete all as specified and directed.
233M&L in repair of exhaust fan motor suitable for 450 mm sweep complete accessories all as specified and directed
234M&L for Preparation old painted surface & painting the geyser complete after cleaning & applying the same one coat of spray paint of white enamel, writing MES No incluing taking down and refixing in same or other place complete all as specified & as directed by Engr -in-Charge.
235Taking down ceiling fan 1200mm/1400mm and wall mounted fan 300/450 mm sweep from position by duly disconnecting electric lines, preparing the surfaces, filling cavities with filler, after cleaning all dust, spray painting with one finishing coat of synthetic enamel paint including writing MES NO and replacing the split pin, rubber pully etc., including refixing and connecting the same complete all as specified and as directed.
236Inspection, disconnecting electric connecting and dismantling of ceiling fan/exhaust/wall mounted fan of any type/size, cleaning including oiling and greasing the bearing, tighting of nuts and bolts and refixing on the old place complete after necessary repair/replacement of old parts all as specified & as directed. Note : Replacement of old parts shall be measured & paid separately.
237Supply only ball bearing of various sizes / make as required for ceiling fans/wall mounting / exhaust fan including greasing complete all as specified and as directed.
238Supply only Gun metal bush of any size / make suitable for ceiling fans all as specified and as directed.
239Supply only capacitor 2.5 Mfd suitable for ceiling / exhaust /wall mounting fans complete all as specified and as directed.
240Supply only capacitor 4.0 Mfd suitable for ceiling / exhaust/wall mounting fans complete all as specified and as directed.
241PVC flexible cable twin twisted core of 23/0.0076 size multi stranded copper conductor suitable for connecting ceiling fans / exhaust /wall mounting fans complete all as specified and as directed.
242Rubber bush with MS bolts, nuts & washers with 'U' clamps for ceiling fans complete all as specified and as directed.
243Dismantling /opening the ceiling fan of 1200 mm sweep of any make and type, removing the old defective winding carefully, cleaning the inner parts and rewinding with the same gauge supper enamelled copper conductor of good insulation, varnishing, drying and reassembling/re-fixing in its p complete all as specified and as directed.
244Dismantling /opening the ceiling fan of 1400 mm sweep of any make and type, removing the old defective winding carefully, cleaning the inner parts and rewinding with the same gauge supper enamelled copper conductor of good insulation, varnishing, drying and reassembling complete all as specified and as directed.
245Dismantling /opening the wall mounted fan of 300 mm sweep of any make and type, removing the old defective winding carefully, cleaning the inner parts and rewinding with the same gauge supper enamelled copper conductor of good insulation, varnishing, drying and reassembling complete all as specified and as directed.
246Taking down exhaust fans 230 mm/300mm / 450mm sweep from position by duly disconnecting electric lines, preparing the surfaces, filling cavities with filler, after cleaning all dust, spray painting with one finishing coat of synthetic enamel paint including writing MES NO and replacing the split pin, rubber pully etc., including refixing and connecting the same complete all as specified and as directed.
247Dismantling /opening the exhaust fan of 230 mm/300 mm sweep of any make and type, removing the old defective winding carefully, cleaning the inner parts and rewinding with the same gauge supper enamelled copper conductor of good insulation, varnishing, drying and reassembling complete all as specified and as directed.
248Dismantling /opening the exhaust fan of 450 mm sweep of any make and type, removing the old defective winding carefully, cleaning the inner parts and rewinding with the same gauge supper enamelled copper conductor of good insulation, varnishing, drying and reassembling complete all as specified and as directed.
249M&L extension of down rod for ceiling fan upto 1.5 mtr including nut, bolts , washers complete accessories all as specified and as directed.
250Excavation in trenches not exceeding 1.5M wide and not exceeding 1.5M deep for laying cables and for foundation of poles etc and getting out in loose/soft soil.
251Returning, filling in, including spreading, levelling, watering and well ramming, in layers not exceeding 25 cm complete using soil.
252Removing excavated surplus soil to a distance exceeding 250m but not exceeding 500m and depositing where directed at a level not exceeding 1.5m above the starting point all as directed.
253M&L for sand cushioning with a layer of M sand 23 cm thick under and above the cable complete all as specified and as directed
254S&L sub class burnt bricks for cable protection complete as specified as directed
255S&L XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armouned power cables (heavy duty) with aluminium conductor, 1100 volts grade, cross sectional area 16 Sqmm 4 core laid in trenches.
256S&L XLPE insulated, screened, PVC bedded, galvanised steen strip or wire armouned power cables (heavy duty) with aluminium conductor, 1100 volts grade, cross sectional area 35 Sqmm, 3.5 core laid in trenches/wall.
257S&L XLPE insulated, screened, PVC bedded, galvanised steen strip or wire armouned power cables (heavy duty) with aluminium conductor, 1100 volts grade, cross sectional area 25 Sqmm, 4 core laid in trenches/wall.
258S&L XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armouned power cables (heavy duty) with aluminium conductor, 1100 volts grade, cross sectional area 10 Sqmm 4 core laid in trenches.
259S&L XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armouned power cables (heavy duty) with aluminium conductor, 1100 volts grade, cross sectional area 10 Sqmm 2 core laid in trenches.
260S&L XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armouned power cables (heavy duty) with aluminium conductor, 1100 volts grade, cross sectional area 6 Sqmm 2 core laid in trenches.
261S&F in repair capacitor 2.5 Mfd suitable for ceiling / exhaust /wall mounting fans complete all as specified and as directed.
262S&F heating element of 2 KW rating triangular / round type as per existing size and type including rubber washers all as specified & as directed.
263S&F heating element of 2 KW rating Hexagonal spiral / bend type as per existing size and type including rubber washers all as specified & as directed.
264S&F Thermostat / auto cut off of suitable size and type for 25/50 Ltrs capacity of any size.
265S&F in repair wall mounted busbar chamber 4 way with 200 A rated busbar for cable termination and end connection as specifide and as directed
266S&F in repair wall mounted busbar chamber 4 way with 200 A rated busbar for cable termination and end connection as specifide and as directed Please Enable Macros to View BoQ information
267S&F in repair wall mounted busbar chamber 4 way with 200 A rated busbar for cable termination and end connection as specifide and as directed Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 56691889
AUTHORITY Statutory Bodies & Commissions/Committees
TENDER VALUE 45 Lakhs
LAST DATE 18-08-2026
Authority
Authority Name Military Engineer Services
Work Description Tender for Repair / Maintenance Of B/R & E/M Items & Redressal Of Day To Day B/R & E/M Compliant In Md & Otm Accn Of Dgqa In The Aor Of Ge (North) Bangalore
Basic Detail
Tender No 8354
Bidding Type Tender
Location
City Bengaluru Urban
State Karnataka
Key Dates
Publish Date 28 Jul 2026
Submission Date 18 Aug 2026
Open Date 20 Aug 2026
Finance
Tender Value 45 Lakhs
Tender Fee 500
EMD 90000
Exemption Available
Document List
2d3b72d0-a795-4212-96a3-9cd5a9df7269.html
8354Tender.pdf
BOQ_875125.xls
Tendernotice_1.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Jul 28, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Aug 18, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 19 days
Aug 20, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 21 days

Tender Documents

Download All (ZIP) ↓
html

2d3b72d0-a795-4212-96a3-9cd5a9df7269.html

pdf

8354Tender.pdf

xls

BOQ_875125.xls

pdf

Tendernotice_1.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail
Loading tenders