Power Government Departments Closing in 9 days TDR #56691814

Tender For Work Of Renovation Of Overhead Lt Distribution Network Of 22 Nos Of Distribution Transformer Centres And Improvement Of Voltage At Different Locations Under Canacona Constituency Of Sub-Division-Iii, Canacona, Div-Xvi, Margao

Issued by Government Departments · goa, Goa
Tender Value
8.58 Crore
Estimated cost
Bid Submission
10 Aug 2026
9 days left
EMD
17.16 Lakhs
Bank guarantee accepted
Document Fee
1500
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
goa → Goa
EMD Exemption
Not Available
Quantity
Not Available

Project Description

Tender for Work Of Renovation Of Overhead Lt Distribution Network Of 22 Nos Of Distribution Transformer Centres And Improvement Of Voltage At Different Locations Under Canacona Constituency Of Sub-Division-Iii, Canacona, Div-Xvi, Margao

BOQ

Name of Work:- Work of Renovation of Overhead LT Distribution Network of 22 nos of Distribution Transformer Centres and Improvement of Voltage at different locations under Canacona Constituency of sub-Division-III, Canacona, Div-XVI, Margao
Sl. No. Item Description
1Supply
2Supply of 9.0 meters long R.C.C. Pole.
3Supply of 7.5 meters long R.C.C. Pole.
4Supply of stay set for 7.5 Mtrs long RCC Pole as per technical specification [Galvanising should be hot dipped Galvanised as per IS:2629/66, minimum Zinc coating of 1000 gms/sq.mtr, 140 Microns DFT), suitable for high salinity coastal areas]
5Supply of HDGI stay rod with plate complete for 9 mts. Long RCC pole as per technical specification [Galvanising should be hot dipped Galvanised as per IS:2629/66, minimum Zinc coating of 1000 gms/sq.mtr, 140 Microns DFT), suitable for high salinity coastal areas]
6Supply of Enamelled danger board as per DRG No. CEE/490
7Supply of Hot dip galvanised structure material for mounting Distribution box [Galvanising should be hot dipped Galvanised as per IS:2629/66, minimum Zinc coating of 1000 gms/sq.mtr, 140 Microns DFT), suitable for high salinity coastal areas]
8Supply of HDGI L.A./S.A. cross arm clamps suitable for 9mts RCC pole as per Drg No. CEE/E-524. [Galvanising should be hot dipped Galvanised as per IS:2629/66, minimum Zinc coating of 1000 gms/sq.mtr, 140 Microns DFT), suitable for high salinity coastal areas]
9Supply of HDGI L.A./S.A. cross arm clamps suitable for 7.5 RCC pole as per Drg No. CEE/E-524. [Galvanising should be hot dipped Galvanised as per IS:2629/66, minimum Zinc coating of 1000 gms/sq.mtr, 140 Microns DFT), suitable for high salinity coastal areas]
10Supply of MS Distribution Box alongwith 12nos. 200A Kit Kat fuse and MCCB of 400Amps, 415 Volts. The box shall be fabricated with MS sheet 12 gauge with overlapping rain proof slit ventilators on both sides of the distribution box with wire mesh to prevent entry of insects with pin head door hinges locking arrangement and shall have required number of bus bars made out of Aluminium strips of size 40 x 10mm for connecting MCCB, fuses and cables (for 4 feeder arrangement) & other accessories. The box shall also have 'magnetic hold' arrangement to ensure that the box doors always remains in 'closed' positiion when shut even without latching.
11Supply of Loss Level-II 200KVA, 11/0.433KV 3 PH. Aluminium Wound Distribution Transformer as per technical specification.
12Earthing complete with 40mm GI Pipe, 2.5 mts long alongwith 20 kgs each salt, charcoal complete with brick masonary. [Galvanising should be hot dipped Galvanised as per IS:2629/66, minimum Zinc coating of 1000 gms/sq.mtr, 140 Microns DFT), suitable for high salinity coastal areas]
13Supply of AAC ' ANT ' conductor of size 7/3.14mm. The stringing rate includes transportation, jointing, etc. 7.44 Kms of conductor shall be strung as phases for LT line. The conductor shall be comply to the technical specification.
14Supply of AAC ' GNAT ' size 7/2.21mm conductor for neutral, streetlight and jumpering as well as guarding. The conductor shall be comply to technical specification.
15Supply of HDGI 4 pin LT cross arm channel type as per Drg. No. CEE/E/705. [Galvanising should be hot dipped Galvanised as per IS:2629/66, minimum Zinc coating of 1000 gms/sq.mtr, 140 Microns DFT), suitable for high salinity coastal areas]
16Supply of HDGI 2 pin LT cross arm channel type as per Drg. No. CEE/E/704. [Galvanising should be hot dipped Galvanised as per IS:2629/66, minimum Zinc coating of 1000 gms/sq.mtr, 140 Microns DFT), suitable for high salinity coastal areas]
17Supply of a) L.T. brown glazed porcelain pin insulators of size 100mm x 70mm conforming to type 1 fig 1 of IS:1445/1977 with amendment 2 of Feb.1981 (second revision) as amended upto date. Minimum failing load shall be 3.5kN & b) Forged G. I. Pin conforming to IS 7935/1975 as amended upto date suitable for L.T. porcelain pin insulator type 1 conforming to fig.1 of IS: 1445/77 with amendment No. 2, Feb.1981, of size 100 x 70 mm. G. I. pin shall comprise of G. I. nut and spring washer and conform to fig. No. 2 of IS: 7935/1975.
18Supply of a) L.T. brown glazed shackle insulators of size 100mm x 115mm conforming to fig.No.4 and type 2 of IS: 1445/77 as amended upto date. Minimum failing load shall be 16kN & b) G. I hardware suitable for L. T. shackle insulators of size 100 x 115 mm. conforming to type 2, fig. 4 of IS: 1445/77 as amended upto date. Hardware or fitting shall conform to fig. 4 of IS 7935-1975 as amended up to date, comprise of 2 G. I. strips, 2 G. I. bolts and 2 nuts with spring washers.
19Supply HDGI G.I. Hexagonal head bolts and hexagonal nuts conforming to IS 1363 part I to III 1992 as amended upto date of the size 3 ½\\" x 5/8\\" or 4\\" x 5/8\\",6\\"x5/8\\", 8\\"x5/8\\" or as per the requirement.
20Providing of Low Tension metering to the DTC by Suplying of following Materials: 1) Epoxy resin Cast L.T. CT coil of 300/5A, Class-0.5s, 50Hz,660V, Burden 15VA conforming to IS-2705 / 1992 as amended upto date 2) Electronic 3Phase,4wire ,Trivector Meter ,LT CT operated 3x240V,-/5A,50Hz, class 0.5s, Category \\"A\\" (DLMS COSEM Protocol) for DTC with RS 232 Optical port and complience to BIS ICS Doc: ETD 13(6211) and latest. 3) 1.1KV multistand copper conductor 2.5sq.mm, XLPE insulated, armoured control cable conforming to relevant IS amended upto date.4) Pole mounted M.S Box ( outdoor type) for Electronic Meter as Drawing No.EE/VIII/64(REV) 5 Al. L shape flat 40mm suitable for mounting on bushing rod and brass lug.
21Supply of CAMR Modem as per technical specification.
22Supply of XLPE cable armoured 3 ½ core 185 sqmm 1.1kv grade.
23Supply of XLPE cable armoured 3 ½ core 120sqmm 1.1kv grade.
24Supply of Aluminium Lugs, size 185 sq.mm as per technical specification
25Supply of Aluminium Lugs, size 120 sq.mm as per technical specification
26Supply of XLPE cable 11KV 3C X 300 sq.mm armoured
27Supply of XLPE cable 11KV 3C X 95 sq.mm armoured
28Supply of H.S 11K V Straight through joint 3 core, 300 SQMM
29Supply of H.S.11 KV Termination kit indoor 300 sqmm. XLPE 3 core
30Supply of H.S.11 KV Termination kit indoor 95 sqmm. XLPE 3 core
31Supply of H.S.11 KV Termination kit outdoor 95 sqmm. XLPE 3 core
323 WAY RMU, 11KV, 630A, 21 kA 3Sec, SF6 Outdoor RMU – 2LBS + 1CB Extensible/Non-Extensible Two (2) Motor operated load break switches (LBSs) with Manual operated earthing switches in SF6 and One (1) vacuum circuit breaker with Electrical closing and tripping along with disconnector and earthing switches SCADA Compatible and base channel. Battery charger along with batteries required for Electrical operations of RMU is in the scope of the Bidder. Each module shall consist of VPIS, FPI in LBS Module (N-1) but not less than 1 no’s per RMU. Suitable arrangement for mounting FRTU, modem or Ethernet Switch/LIU along with battery, battery charger shall be provided in RMU.
33Supply and filling of sand in plinth under floors , trenches including waterin ,ramming consolidating ,dressing complete.
34Providing and laying in position cement concrete 1:2:4 (1 cement : 2 coarse sand: 4 graded granitic or basaltic stone aggregate 40 m nominal size)excluding cos t of centering and shuttering and finishing for foundations.ALL WORKS UPTO PLINTH LEVEL
35Providing Centering and shuttering including struttings, propping etc and removal of formwork
36Supply and Providing of 12mm cement plaster 1:4 (1 - cement: 4 - fine sand) for foundations.
37Brick work using common burnt building bricks in cement mortar 1:4 (1 cement : 4 coarse sand) with bricks of class designation 75 kgs/ cm2 (wire cut bricks)
38Supply and laying of burnt clay wire cut bricks of 75 Kgs/cm2 class.Wire cut bricks.
39Supply of GI Tubular Fencing complete with gate and side dismantling syatem as per the specification for distribution transformers and feeder Pillars (size 4M X 3M X 2M) with concreting for GI fencing supports with plinth(0.3x0.3x0.5) Cu.mx12 nos. Each ratio 1:3:6 and brick masonary [Galvanising should be hot dipped Galvanised as per IS:2629/66, minimum Zinc coating of 1000 gms/sq.mtr, 140 Microns DFT, suitable for high salinity coastal areas].
40Supply of underground cable protective cover as per specification as given below:PCC precast cable protective cover of size 480mmX250mmX50mm casted by confined mold vibratory cast of concrete mix M30, having strength of 30N/mm2 at 28 days.
41Supply of Class B HDGI pipe of diameter 150 mm dia. [Galvanising should be hot dipped Galvanised as per IS:2629/66, minimum Zinc coating of 1000 gms/sq.mtr, 140 Microns DFT), suitable for high salinity coastal areas]
42Supply of Class B HDGI pipe of diameter 100 mm dia for cable rising.
43Supply of GI Flat 25 x 5 mm. [Galvanising should be hot dipped Galvanised as per IS:2629/66, minimum Zinc coating of 1000 gms/sq.mtr, 140 Microns DFT), suitable for high salinity coastal areas]
44Supply of RCC Cable route Marker
45Single Phase 4KVA CCMS Panel
46LED Street Light 30Watts
47Supply of AAC ' Weasel conductor for connecting earthings.
48COST OF ERECTION
49Erection of 9.0 meters long R.C.C. Pole.
50Erection of 7.5 meters long R.C.C. Pole.
51Erection of stay set for 7.5 Mtrs long RCC Pole as per technical specification
52Erection of HDGI stay rod with plate complete for 9 mts. Long RCC pole as per technical specification
53Erection of Enamelled danger board as per DRG No. CEE/490
54Fabrication, transportation and erection of Hot dip galvanised structure material for mounting Distribution box
55Fixing of HDGI L.A./S.A. cross arm clamps suitable for 9mts RCC pole as per Drg No. CEE/E-524.
56Fixing of HDGI L.A./S.A. cross arm clamps suitable for 7.5 RCC pole as per Drg No. CEE/E-524.
57Erection and commissioning of MS Distribution Box alongwith 12nos. 200A Kit Kat fuse and MCCB of 400Amps, 415 Volts. The box shall be fabricated with MS sheet 12 gauge with overlapping rain proof slit ventilators on both sides of the distribution box with wire mesh to prevent entry of insects with pin head door hinges locking arrangement and shall have required number of bus bars made out of Aluminium strips of size 40 x 10mm for connecting MCCB, fuses and cables (for 4 feeder arrangement) & other accessories. The box shall also have 'magnetic hold' arrangement to ensure that the box doors always remains in 'closed' positiion when shut even without latching.
58Erection, testing and commissioning of Loss Level-II 200KVA, 11/0.433KV 3 PH. Aluminium Wound Distribution Transformer as per technical specification.
59Earthing complete with 40mm GI Pipe, 2.5 mts long alongwith 20 kgs each salt, charcoal complete with brick masonary.
60Stringing of AAC ' ANT ' conductor of size 7/3.14mm. The stringing rate includes transportation, jointing, etc. 7.44 Kms of conductor shall be strung as phases for LT line. The conductor shall be comply to the technical specification.
61Supply and Stringing of AAC ' GNAT ' size 7/2.21mm conductor for neutral, streetlight and jumpering as well as guarding. The conductor shall be comply to technical specification.
62fixing of HDGI 4 pin LT cross arm channel type as per Drg. No. CEE/E/705.
63fixing of HDGI 2 pin LT cross arm channel type as per Drg. No. CEE/E/704.
64Fixing of a) L.T. brown glazed porcelain pin insulators of size 100mm x 70mm conforming to type 1 fig 1 of IS:1445/1977 with amendment 2 of Feb.1981 (second revision) as amended upto date. Minimum failing load shall be 3.5kN & b) Forged G. I. Pin conforming to IS 7935/1975 as amended upto date suitable for L.T. porcelain pin insulator type 1 conforming to fig.1 of IS: 1445/77 with amendment No. 2, Feb.1981, of size 100 x 70 mm. G. I. pin shall comprise of G. I. nut and spring washer and conform to fig. No. 2 of IS: 7935/1975.
65Fixing of a) L.T. brown glazed shackle insulators of size 100mm x 115mm conforming to fig.No.4 and type 2 of IS: 1445/77 as amended upto date. Minimum failing load shall be 16kN & b) G. I hardware suitable for L. T. shackle insulators of size 100 x 115 mm. conforming to type 2, fig. 4 of IS: 1445/77 as amended upto date. Hardware or fitting shall conform to fig. 4 of IS 7935-1975 as amended up to date, comprise of 2 G. I. strips, 2 G. I. bolts and 2 nuts with spring washers.
66fixing HDGI G.I. Hexagonal head bolts and hexagonal nuts conforming to IS 1363 part I to III 1992 as amended upto date of the size 3 ½\\" x 5/8\\" or 4\\" x 5/8\\",6\\"x5/8\\", 8\\"x5/8\\" or as per the requirement.
67Providing of Low Tension metering to the DTC by Installing and commissioning of following Materials: 1) Epoxy resin Cast L.T. CT coil of 300/5A, Class-0.5s, 50Hz,660V, Burden 15VA conforming to IS-2705 / 1992 as amended upto date 2) Electronic 3Phase,4wire ,Trivector Meter ,LT CT operated 3x240V,-/5A,50Hz, class 0.5s, Category \\"A\\" (DLMS COSEM Protocol) for DTC with RS 232 Optical port and complience to BIS ICS Doc: ETD 13(6211) and latest. 3) 1.1KV multistand copper conductor 2.5sq.mm, XLPE insulated, armoured control cable conforming to relevant IS amended upto date.4) Pole mounted M.S Box ( outdoor type) for Electronic Meter as Drawing No.EE/VIII/64(REV) 5 Al. L shape flat 40mm suitable for mounting on bushing rod and brass lug.
68Erection of XLPE cable armoured 3 ½ core 185 sqmm 1.1kv grade.
69erection of XLPE cable armoured 3 ½ core 120sqmm 1.1kv grade.
70crimping of Aluminium Lugs, size 185 sq.mm as per technical specification
71crimping of Aluminium Lugs, size 120 sq.mm as per technical specification
72Erection of XLPE cable 11KV 3C X 300 sq.mm armoured
73Erection of XLPE cable 11KV 3C X 95 sq.mm armoured
74Erection of H.S 11K V Straight through joint 3 core, 300 SQMM
75Erection of H.S.11 KV Termination kit indoor 300 sqmm. XLPE 3 core
76Erection of H.S.11 KV Termination kit indoor 95 sqmm. XLPE 3 core
77Erection of H.S.11 KV Termination kit outdoor 95 sqmm. XLPE 3 core
783 WAY RMU, 11KV, 630A, 21 kA 3Sec, SF6 Outdoor RMU – 2LBS + 1CB Extensible/Non-Extensible Two (2) Motor operated load break switches (LBSs) with Manual operated earthing switches in SF6 and One (1) vacuum circuit breaker with Electrical closing and tripping along with disconnector and earthing switches SCADA Compatible and base channel. Battery charger along with batteries required for Electrical operations of RMU is in the scope of the Bidder. Each module shall consist of VPIS, FPI in LBS Module (N-1) but not less than 1 no’s per RMU. Suitable arrangement for mounting FRTU, modem or Ethernet Switch/LIU along with battery, battery charger shall be provided in RMU.
79Earthwork in excavation by mechanical means (hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sq.m on plan) including disposal of excavated earth lead upto 50 m and lift upto 1.5m disposed earth to be leveled and neatly dressed including providing barricading, danger lighting guarding as directed in
80Refilling the pipeline/foundation trenches plinth sides, foundation etc. with available excavated earth in layers not exceeding 20 cm depth consolidating each layer ramming and watering lead upto 50 M and all lifts and disposal of surplus earth as directed by Engineer in Charge.
81Disposal of exavated soil
82Erection of GI Tubular Fencing complete with gate and side dismantling syatem as per the specification for distribution transformers and feeder Pillars (size 4M X 3M X 2M) with concreting for GI fencing supports with plinth(0.3x0.3x0.5) Cu.mx12 nos. Each ratio 1:3:6 and brick masonary [Galvanising should be hot dipped Galvanised as per IS:2629/66, minimum Zinc coating of 1000 gms/sq.mtr, 140 Microns DFT, suitable for high salinity coastal areas].
83Laying of underground cable protective cover as per specification as given below:PCC precast cable protective cover of size 480mmX250mmX50mm casted by confined mold vibratory cast of concrete mix M30, having strength of 30N/mm2 at 28 days.
84Laying of Class B HDGI pipe of diameter 150 mm dia.
85Laying of Class B HDGI pipe of diameter 100 mm dia for cable rising.
86Erection of GI Flat 25 x 5 mm.
87Erection of RCC Cable route Marker
88Removing of the existing 7.5 m RCC pole.
89Removing of the existing 9.0 m RCC pole.
90Removing of the existing 11.00m 90lb/yb Rail pole.
91Removing and re-fixing of the existing service conenction single phase.-(PVC wire 2C x 4sq.mm 1.1 KV Grade)
92Removing and re-fixing of the existing service conenction three phase.(PVC wire 2C x 6sq.mm 1.1 KV Grade)
93Removing of 4 Pin cross arms assembly with Clamps, Nut & Bolt for 7.5/ 9.00 Mtr RCC poles/ rail pole.
94Removing of 2 Pin cross arms assembly with Clamps, Nut & Bolt.
95Removing of LT shackle insulator with metal parts.
96Removing of LT Pin Insulator with G.I. pin.
97Removing of the existing Old deteriorated ANT conductor.
98Removing of the existing Old deteriorated GNAT conductor.
99Removing & Re Fixing of LED Street Lights
100Removing & Re fixing of Eixing of Street Light clamp 25mm pipe (Top/bottom)
101Removing & Re Fixing of G.I Bent Pipe 1mx25mm
102Single Phase 4KVA CCMS Panel
103LED Street Light 30Watts
104Stringing of AAC ' Weasel conductor for connecting earthings. Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 56691814
AUTHORITY Government Departments
TENDER VALUE 8.58 Crore
LAST DATE 10-08-2026
Authority
Authority Name Department Of Electricity
Work Description Tender for Work Of Renovation Of Overhead Lt Distribution Network Of 22 Nos Of Distribution Transformer Centres And Improvement Of Voltage At Different Locations Under Canacona Constituency Of Sub-Division-Iii, Canacona, Div-Xvi, Margao
Basic Detail
Tender No Tender 09(2026-27)/CSC
Bidding Type Tender
Location
City goa
State Goa
Key Dates
Publish Date 28 Jul 2026
Submission Date 10 Aug 2026
Open Date 12 Aug 2026
Finance
Tender Value 8.58 Crore
Tender Fee 1500
EMD 17.16 Lakhs
Exemption Not Available
Document List
ad0c8683-f125-4fe6-ae2a-5a9bd1ff03a1.html
BOQ_31039.xls
Tendernotice_1 (17).pdf
Tendernotice_2 (4).pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Jul 28, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Aug 10, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 9 days
Aug 12, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 11 days

Tender Documents

Download All (ZIP) ↓
html

ad0c8683-f125-4fe6-ae2a-5a9bd1ff03a1.html

xls

BOQ_31039.xls

pdf

Tendernotice_1 (17).pdf

pdf

Tendernotice_2 (4).pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail
Loading tenders