Tender For Renovation Of Iei Of Port Control Tower (Pct), Mayabunder
Tender Value
5.53 Lakhs
Estimated cost
Bid Submission
06 Aug 2026
5 days left
EMD
11078
Bank guarantee accepted
Document Fee
Ref. Documents
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
North and Middle Andaman → Andaman And Nicobar Islands
EMD Exemption
Not Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender for Renovation Of Iei Of Port Control Tower (Pct), Mayabunder
BOQ
| Sl. No. | Item Description |
| 1 | Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required. |
| 2 | Group C |
| 3 | Wiring for light/ power plug with 2X4 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit alongwith 1 No. 4 sq. mm FRLS PVC insulated copper conductor single core cable for loop earthing as required. |
| 4 | Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required. |
| 5 | 2 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire |
| 6 | 2X 6 sq. mm +1 X 6 sq. mm earth wire |
| 7 | Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 A modular socket outlet and 5/6 A modular switch, connections etc. as required. |
| 8 | Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 A & 15/16 A modular socket outlet and 15/16 A modular switch, connections etc. as required. |
| 9 | Supplying and fixing 3 pin, 5 A ceiling rose on the existing junction box/ wooden block including connections etc. as required. |
| 10 | Supplying and fixing of call bell / buzzer suitable for single phase, 230 volts complete as reqd. |
| 11 | Supplying and fixing brass batten/ angle holder including connection etc. as required |
| 12 | Installation ,Testing, Commissioning of wall bracket /ceiling fittings of all sizes and shapes containing upto two GLS/CFL/LED lamps per fitting, complete with all accessories including connections etc. as required. |
| 13 | Installation, testing and commissioning of pre-wired, fluorescent fitting / compact fluorescent fitting of all types, complete with all accessories and tube/lamp etc. directly on ceiling/ wall, including connections with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable and earthing etc. as required. |
| 14 | Installation, testing and commissioning of ceiling fan, including wiring the down rods of standard length (upto 30 cm) with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable etc. as required. |
| 15 | Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required |
| 16 | Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) |
| 17 | 6 way (4 + 18), Double door |
| 18 | Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, “C” curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. |
| 19 | Single pole |
| 20 | Supplying and fixing following rating, four pole, 415 V, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required. |
| 21 | Supplying and fixing 20 A, 240 V, SPN Industrial type socketoutlet, with 2 pole and earth, metal enclosed plug top alongwith 20 A \\"C\\" curve, SP, MCB, in sheet steel enclosure, on surface or in recess, with chained metal cover for the socket outlet and complete with connections, testing and commissioning etc. as required |
| 22 | Earthing with G.I. earth pipe 4.5 metre long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc.with charcoal/ coke and salt as required |
| 23 | Providing and fixing 25 mm X 5 mm G.I. strip in 40 mm dia G.I.pipe from earth electrode including connection with G.I. nut, bolt, spring, washer excavation and re-filling etc. as required. |
| 24 | Providing and fixing 25 mm X 5 mm G.I. strip on surface or in recess for connections etc. as required |
| 25 | Supplying of LED 9 watts B22 lamp Make: Philips Ace saver Cool Day bulb or its equalent to ISI standard. |
| 26 | Supplying of 20 Watt bulk head fitting of make D' Mak or its equivalent to ISI standard etc as required. |
| 27 | Supplying of 20 watts ultraslim LED Batten with LED tubes white CDL of make: Crompton Laser or its equivalent to ISI standard. |
| 28 | Supplying of BLDC Ceiling fan 1200 mm sweep with regulator of make: Atomberg Renessa Prime or equivalent to ISI standard. |
| 29 | Supply, installation, testing and commissioning of following capacity and rating wall mounted split Air conditioner, inverter type fitted with rotary compressor operating on 230v ± 10%, 50Hz single phase AC supply with evaporator and condensing unit made of copper tubes , cordless remote control, copper piping for both suction and discharge of five (05) meters length with protection covering for piping of suitable size of medium PVC pipe, power and control cabling as per site requirement, outdoor stand duly painted, comprising of following etc. complete as per requirement including first charge of refrigerent of Make: Voltas 5 star plus or its equivalent to ISI standards.a) Insulated copper pipe lines liquid and suction lines as per manufacturer rocommendation.b) Flexible copper cable between indoor & outdoor unit of suitable size as per manufacturer rocommendation. c) Drain pipe.d) Suitable size of PVC pipe for protection covering of refrigent line if required as per direction of E-in-C. |
| 30 | 2.0 TR capacity, 5 star rating |
| 31 | Supplying, installing, testing and commissioning of 5 KVA electronic voltage stabilizer suitable for 2.0 ton Air Conditioner of make: Everest or its equivalent to ISI standard. |
| 32 | Provoding & fixing of pre-fabricated stand for keeping outdoor units of 1.5 Ton/ 2 Ton Capacity split type AC as required. |
| 33 | Supplying and fixing of LED floodlight of capacity 100 watts of make: Havells or its equivalent to ISI standard Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Jul 28, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedAug 06, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 5 daysAug 06, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 5 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender