Tender For 03-Renovation Of Conference Hall Into Judges Lounge & Conversion Of Reading Room Judges Library At 2Nd Floor Into Museum In The High Court Of Jharkhand, Dhurwa, Ranchi (High Court Pool)
Tender Value
80.50 Lakhs
Estimated cost
Bid Submission
03 Aug 2026
3 days left
EMD
1.61 Lakhs
Bank guarantee accepted
Document Fee
10000
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Ranchi → Jharkhand
EMD Exemption
Not Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender for 03-Renovation Of Conference Hall Into Judges Lounge & Conversion Of Reading Room Judges Library At 2Nd Floor Into Museum In The High Court Of Jharkhand, Dhurwa, Ranchi (High Court Pool)
BOQ
| Sl. No. | Item Description |
| 1 | Providing designation 75 B brick work in C.M. (1:6) in superstructure with approved quality of clean coarse sand of F.M. 2 to 2.5 including, providing 10mm thick mortar joints, cost of screening materials, raking out joints to 15mm depth curing, taxes and royalty all complete as per building specification and direction of E/I. |
| 2 | Providing 12mm cement plaster (1:6) with clean coarse sand of F.M. 1.5 including screening, curing with all leads and lifts of water, scaffolding taxes and royalty all complete as per building specification and direction of E/I. |
| 3 | Providing and fixing false ceiling at all heights including providing and fixing of frame work made of special sections, power pressed from M.S. sheets and galvanized with zinc coating of 120 gms/sqm (both side inclusive) as per IS : 277 and consisting of angle cleats of size 25 mm wide x 1.6 mm thick with flanges of 27 mm and 37mm, at 1200 mm centre to centre, one flange fixed to the ceiling with dash fastener 12.5 mm dia x 50 mm long with 6 mm dia bolts, other flange of cleat fixed to the angle hangers of 25x10x0.50 mm of required length with nuts & bolts of required size and other end of angle hanger fixed with intermediate G.I. channels 45x15x0.9 mm running at the spacing of 1200 mm centre to centre, to which the ceiling section 0.5 mm thick bottom wedge of 80 mm with tapered flanges of 26 mm each having lips of 10.5 mm, at 450 mm centre to centre, shall be fixed in a direction perpendicular to G.I. intermediate channel with connecting clips made out of 2.64 mm dia x 230 mm long G.I. wire at every junction, including fixing perimeter channels 0.5 mm thick 27 mm high having flanges of 20 mm and 30 mm long, the perimeter of ceiling fixed to wall/partition with the help of rawl plugs at 450 mm centre, with 25 mm long dry wall screws @ 230 mm interval, including fixing of gypsum board to ceiling section and perimeter channel with the help of dry wall screws of size 3.5 x 25 mm at 230 mm c/c, including jointing and finishing to a flush finish of tapered and square edges of the board with recommended jointing compound , jointing tapes , finishing with jointing compound in 3 layers covering upto 150 mm on both sides of joint and two coats of primer suitable for board, all as per manufacturer's specification and also including the cost of making openings for light fittings, grills, diffusers, cutouts made with frame of perimeter channels suitably fixed, all complete as per drawings, specification and direction of the Engineer in Charge but excluding the cost of painting with : |
| 4 | 12.5 mm thick tapered edge gypsum moisture resistant board |
| 5 | Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. |
| 6 | Providing two coats of plastic emulsion paint of approved shade and make over a coat of cement primer over new surface including preparing plastered surface by rubbing smooth with pumice stone or fine sand paper, applying putty wherever required, scaffolding washing of floor and taxes all complete as per building specification and direction of E/I. |
| 7 | Polishing in high gloss/matt finish melamine clear polish on wood work in required color/wooden shade texture with following process in the sequence as detailed below:1. The surface to be polished is rubbed with sand paper 80/120 no. and then with sand paper of 160/180 nos.2. Applying two coats of sealer with spray gun and allowing sufficient drying time for 1st coat and 2nd coat is allowed to dry for 8 to 12 hrs.3. On drying of sealer coat, wet rubbing with emery cloth of finer grading with ample water to remove excess sealer layer and make the surface further smooth after this wet rubbing, then surface is applied with special grade melamine fillers to fill all the small and big holes/grooves etc. Filler coat to be allowed to dry for 4 to 6 hrs on which again a light wet rubbing is done this surface is further allowed to dry for 12 hrs.4. On this, 1st coat of melamine polish is applied with spray gun using melamine clear polish and melamine thinner in required proportion. This 1st coat is allowed to dry for 24 hrs then this dry surface is again fine wet rubbed smooth, which is further allowed to dry for 12 hrs. The final melamine polish is applied with compressor pressure spray gun using melamine clear polish and melamine thinner mixed in required proportion complete as per direction of Engineer-in-Charge. (Final coat to be done in 1 or 2 layers without gap of time.) |
| 8 | Carriage of materials from source to site work including loading & unloading all complete job as per specification and direction of E/I. |
| 9 | Sand 10 KM |
| 10 | Bricks - 8 KM |
| 11 | Point wiring in PVC conduit, with modular type switch :- Wiring for light point/fan point/exhaust fan point/call bell point with 1.5 sq.mm FR PVC insulated copper conductor single core in surface/recessed PVC conduit, with modular switch, modular plate suitable GI box etc as required. Group C |
| 12 | Circuit/ submain wiring in PVC conduit :- Wiring for circuit/ submain wiring along with earh wire with the following sizes of FR PVC insulated copper conductor single core cable in surface / recessed PVC conduit as required. |
| 13 | 2 x 1.5 sq.mm + 1 x 1.5 sq.mm earth wire |
| 14 | 2 x 2.5 sq.mm + 1 x 2.5 sq.mm earth wire |
| 15 | 2 x 4.0 sq.mm + 1 x 4.0 sq.mm earth wire |
| 16 | Supplying / Fixing PVC conduit :- Supplying and fixing of following sizes of PVC conduit along with accessories in surface / recess including cutting the wall and making good the same in case of recessed conduit as required. |
| 17 | 20 mm |
| 18 | 25 mm |
| 19 | Supplying and fixing suitable size GI box with moduler plate cover in the front on surface or in recess including providing and fixing 3 pin 5/6 amps socket outlet and 5/6 amps. moduler type switch, connections painting etc. as required. (For light plugs). |
| 20 | Supplying and fixing suitable size GI box with moduler plate cover in the front on surface or in recess including providing and fixing 6 pin 15/16 amps socket outlet and 15/16 amps. moduler type switch, connections painting etc. as required. (For power plugs). |
| 21 | ITC fluorescent fitting directly on surface :- Installation testing and commissioning of pre-wired, fluorescent fitting ./ compact fluorescent fitting of all types, complete with all accessories and tube etc. directly / wall. including connection with 1.5 aq.mm FR PVC insulated . copper conductor single core cable and earthing etc. as required. |
| 22 | S.I.T.C of floowing rating reccess/surface mounted LED round/square shape Down light luminarie with pressure die cast housing for single phase supply voltage. Luminarie shall be confirm to IS:10322 part-5/section-2 or IEC:62722 with all neccssary accessories as required |
| 23 | 15/16W LED Round Down light |
| 24 | 12W COB based round LED light with multiple bem angles (36 Degree) |
| 25 | 15W COB based round LED light with multiple bem angles (36 Degree) |
| 26 | Power plug wiring in PVC conduit (2 x 4 sq. mm) :- Wiring for light/power plug with 2 x 4 sq.mm FR PVC insulated copper conductor single core cable in surface/recessed PVC conduit, along with 1 No 4 sq.mm FR PVC insulated copper conductor single core cable for loop earthing etc as required. |
| 27 | S/F Modular type switch/ socket :-Supplying and fixing of following modular switch / soket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. |
| 28 | 5/6 amps, one way switch |
| 29 | 5/ 6 amps, two way switch |
| 30 | 15/ 16 amps, one way switch |
| 31 | 5/6 amps, 3 pin socket outlet |
| 32 | 15/16 amps, 6 pin socket outlet |
| 33 | LED strip light 24volt DC with IP:65 rated in different colours of length 5mtr. and power 5W per mtr. including driver. IS:10322 part 5/ section 7 |
| 34 | Providing and fixing 18 mm thick gang saw cut, mirror polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills, facias and similar locations of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing of edges to give high gloss finish etc. complete at all levels. |
| 35 | Granite stone slab of colour black, Cherry/Ruby red Area of slab over 0.50 sqm |
| 36 | Providing edge moulding to 18 mm thick marble stone counters, Vanities etc., including machine polishing to edge to give high gloss finish etc. complete as per design approved by Engineer-in-Charge.Marble work(Moulding) |
| 37 | Providing and fixing partition upto ceiling height consisting of G.I. frame and required board, including providing and fixing of frame work made of special section power pressed/ roll form G.I. sheet with zinc coating of 120 gms/sqm(both side inclusive), consisting of floor and ceiling channel 50 mm wide having equal flanges of 32 mm and 0.50 mm thick, fixed to the floor and ceiling at the spacing of 610 mm centre to centre with dash fastener of 12.5 mm dia meter 50 mm length or suitable anchor fastener or metal screws with nylon plugs and the studs 48 mm wide having one flange of 34 mm and other flange 36 mm and 0.50 mm thick fixed vertically within flanges of floor and ceiling channel and placed at a spacing of 6 1 0 mm centre to centre by 6 mm dia bolts and nuts, including fixing of studs along both ends of partition fixed flush to wall with suitable anchor fastener or metal screws with nylon plugs at spacing of 450 mm centre to centre, and fixing of boards to both side of frame work by 25 mm long dry wall screws on studs, floor and ceiling channels at the spacing of 300 mm centre to centre. The boards are to be fixed to the frame work with joints staggered to avoid through cracks, M.S. fixing channel of 99 mm width (0.9 mm thick having two flanges of 9.5 mm each) to be provided at the horizontal joints of two boards, fixed to the studs using metal to metal flat head screws, including jointing and finishing to a flush finish with recommended jointing compound, jointing tape, angle beads at corners (25 mm x 25 mm x 0.5 mm), joint finisher and two coats of primer suitable for board as per manufacture's specification and direction of engineer in charge all complete.75 mm overall thickness partition with 1 2 . 5 mm thick double skin fire rated Glass Reinforced Gypsum (GRG) plaster board conforming to IS: 2095: part 3 (Board with BIScertification marks) |
| 38 | Providing and fixing, in position concealed G.I. section for wall paneling using board of required thickness fixed on the 'W' profile (0.55 mm thick) having a knurled web of 51.55 mm and two flanges of 26 mm each with lips of 10.55 mm, placed @ 610 mm CIC in perimeter channel having one flange of 20 mm and another flange of 30 mm with thickness of 0.55 mm and web of length 27 mm. Perimeter channel is fixed on the floor and the ceiling with the nylon sleeves@610 mm CIC with fully threaded self-tapping dry wall screws. Board is fixed to the 'W' profile with 25 mm countersunk ribbed head screws @ 200 mm CIC., all complete as per the drawing & directions of engineer-in-charge, the joints of the boards are finished with specially formulated jointing compound and 48 mm wide jointing tape to provide seamless finish. |
| 39 | Multipurpose cement board reinforced with suitable fibre cement screw. 8 mm thick cement fibre board, Type- B, Category- Ill as per IS: 14862 : 2000. |
| 40 | Providing and fixing thermal insulation with Resin Bonded Fibre glass wool conforming to IS: 8183 having density 24 kg/m3, 50 mm thick, wrapped in 200G Virgin Polythene Bags fixed to wall with screw, rawel plug & washers and held in position by criss crossing GI wire etc. complete as per directions of Engineer-in-Charge. |
| 41 | Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal. 110 mm diameter. |
| 42 | Providing and fixing on wall face unplasticised - PVC moulded fittings/accessories for unplasticised Rigid PVC rain water pipes conforming to IS 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion. |
| 43 | Single tee with door - 110x110x110 mm |
| 44 | Single tee without door - 110x110x110 mm |
| 45 | Bend - 110mm |
| 46 | Shoe - 110mm |
| 47 | Providing and fixing unplasticised -PVC pipe clips of approved design to unplasticised - PVC rain water pipes by means of 50x50x50 mm hard wood plugs, screwed with M.S. screws of required length, including cutting brick work and fixing in cement mortar 1:4 (1 cement : 4 coarse sand) and making good the wall etc. complete. 110mm. |
| 48 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply and all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge.Concealed work, including cutting chases and making good the walls etc. 20 mm dia. |
| 49 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. External work : 25 mm dia. |
| 50 | Providing and fixing C.P. Brass extension nipple (size 15 mm x 50 mm) of approved make and quality as per direction of Engineer-in-charge. |
| 51 | Cutting holes up to 30x30 cm in walls including making good the same : With common burnt clay F.P.S. (non modular) bricks. |
| 52 | Providing and fixing in position pre-cast R.C.C. manhole cover and frame of required shape and approved quality : Rectangular shape 600x450 mm internal dimensions. |
| 53 | Supplying, fiting, fixing 2 Feet Deep Cupboard/ Wardrobe with 19mm thick BWP grade marine ply as per IS 710 of approved brand and stick to Both side 1.0 mm thick laminated including all cost of materials, labour , taxes all complete as per building specification and direction of E/I. |
| 54 | Providing Fitting & Fixing 12mm Toughened glass all complete. |
| 55 | Providing Fitting & Fixing Universal Door Closer all complete as per building specification and direction of E/I. |
| 56 | Supplying fitting fixing all height wall paneling with 12mm ply wood & 4mm veneer over 50mm x 25mm aluminum section veener fininsh with all taxes and royalty all complete as per E/I (As per Analysis) |
| 57 | Providing Fitting and fixing 8mm Thick wooden Flooring Including Fixing with iron screw all complete as per building specification and direction of E/I. |
| 58 | Supplying & Fixing Acrylic Nameplate all complete as per specification and direction of E/I |
| 59 | Providing, fitting anf fixing Table including the cost of all material and labour excluding taxes & royalties all complete as per building specification and instruction of E/I |
| 60 | Supplying fitting fixing all height wall paneling with 19 mm ply wood and 1.0mm Laminate fininsh with all taxes and royalty all complete as per E/I |
| 61 | Supplying, Fitting & Fixing of Aluminium LED Profile complete as per building specification and direction of E/I. |
| 62 | Providing and fixing 12 mm thick plywood (Green Ply/Green Panel) on existing door Frame and Pasting with 1mm Leminate (Green Decor) with material and labour all complete (including all fancy type fitting) as per building specification and direction of E/I. |
| 63 | Providing and fixing 32 mm door shutter wooden framed by both side best quality ply and 4mm thick water proof Veneer both side pasting finishing with all material and labour all complete (including all fancy type fitting) as per building specification and direction of E/I. |
| 64 | S/F/F Wardrobe Cabinet Laminate Finish including all materials, labour , taxes all complete as per building specification and direction of E/I. |
| 65 | Supplying, Fitting & Fixing of Roller Blinds all taxes and labour complete as per building specification and direction of E/I. |
| 66 | Supply, Fitting & Fixing 2-Seater Sofa With Febric Cover all complete as per building specification and direction of E/I. |
| 67 | Supply Fitting & Fixing CENTER TABLE With Marble Top (1219mmx711mm) all complete as per building specification and direction of E/I. |
| 68 | Supply Fitting & Fixing SIDE TABLE all complete as per building specification and direction of E/I. Diia - 500mm & Height 650 mm |
| 69 | Providing and fixing Mirror Hanging System all complete as per building specification and direction of E/I. |
| 70 | Providing and fixing of Connection Pipe all complete as per building specification and direction of E/I. |
| 71 | Providing and fixing Angular Stop Cock all complete as per building specification and direction of E/I. |
| 72 | Supplying, Fitting & Fixing of Wash Basin with Pedestal all complete as per building specification and direction of E/I. |
| 73 | Supplying, fitting & fixing of WASH BASIN COUPLING all complete as per building specification and direction of E/I. |
| 74 | Supplying, fitting & fixing Bib Tap for wash basin all complete as per building specification and direction of E/I. |
| 75 | Supplying, fitting & fixing soap dispenser all complete as per building specification and direction of E/I. |
| 76 | Supplying, fitting & fixing Towel Ring all complete as per building specification and direction of E/I. |
| 77 | Supplying, fitting & fixing Waste Jali all complete as per building specification and direction of E/I. |
| 78 | Supplying and Fixing of automatic sensor hand dryer all complete as per specification and direction of E/I |
| 79 | Supplying Microwave all complete as per specification and direction of E/I. |
| 80 | Supplying Induction all complete as per specification and direction of E/I. |
| 81 | Supplying Fridge Double Door all complete as per specification and direction of E/I. |
| 82 | Supplying Fixing Steel plate Etching with Radium all complete as per specification and direction of E/I. |
| 83 | Supplying, fitting & fixing Cool Chandelier 50 Watt all complete as per building specification and direction of E/I. |
| 84 | Add 18 % GST (in Basic Rate must fill 12) |
| 85 | Add 1% Labour Cess (in Basic Rate must fill 1) Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Jul 27, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedAug 03, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 3 daysAug 04, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 4 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender