Tender For Construction Of Additional Structure (2400 Sqft) In The Existing Structure Along With Furnishing And Furbishing At Educational Museum At Bhubaneswar (Composite)
Tender Value
2.31 Crore
Estimated cost
Bid Submission
10 Aug 2026
9 days left
EMD
2.31 Lakhs
Bank guarantee accepted
Document Fee
10000
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Khordha → Odisha
EMD Exemption
Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender for Construction Of Additional Structure (2400 Sqft) In The Existing Structure Along With Furnishing And Furbishing At Educational Museum At Bhubaneswar (Composite)
BOQ
| Sl. No. | Item Description |
| 1 | CIVIL WORKClearing, Grubbing and removal including uprooting rank vegetation grass, bushes, shrubs, existing barb wire fence and conc pillar etc complete. |
| 2 | Boundary Wall |
| 3 | Dismantling brick or stone masonry in lime or cement mortar in all floors at all heights and stacking the useful materials for reuse and removing the debris away from the work site with all leads including cost of all labour, sundries and T&P. etc. required for the work complete as directed by the Engineer-in-charge. |
| 4 | Ground Floor |
| 5 | First Floor |
| 6 | Second Floor |
| 7 | Dismantling the old damaged RCC structures like RCC column, Beam, lintel, stair case etc., Stacking the useful materials for reuse including removing and depositing the debrises away from working area with 50m lead.including cost of all labour, sundries and T&P. etc. required for the work complete as directed by the Engineer-in-charge. |
| 8 | Second Floor |
| 9 | Dismantling & removing of 2.5mm thick A.S. flooring and stacking the useful materials for reuse and removing the debris away from the work site with all leads including cost of all labour, sundries and T&P. etc. required for the work complete as directed by the Engineer-in-charge. |
| 10 | Ground Floor (Garage) |
| 11 | Dismantling & removing doors, windows, & ventilator including removal of frame, hinges, fastening & stacking the same for reuse and removing the debris with in 50. m Lead. |
| 12 | Ground Floor |
| 13 | Dismantling and removing cement concrete from chajja/haller including stacking the useful materials away from work site for reuse and removing the debrises within 50m. lead including cost of all labours, sundries and T&P. etc. complete. |
| 14 | Ground Floor |
| 15 | Dismantling and removing the A/C sheet / G.C. I sheet roofing after carefully removing ‘J’ or ‘L’ hooks or washers in all floors at all heights and stacking the useful materials for reuse and removing the debris away from the work site with all leads including cost of all labour, sundries and T&P. etc. required for the work complete as directed by the Engineer-in-charge. |
| 16 | Ground Floor |
| 17 | Removing old lime or cement plaster from walls including raking out joints 12 mm deep & removing the debris with in 50. m Lead. |
| 18 | Façade |
| 19 | Scraping old paint with scrapers, sand papering and washing with soap water or soda including scaffolding charges up to 5m height. |
| 20 | Existing Building Demolish |
| 21 | Height Above 5.0m |
| 22 | Earth work excavation of foundation trenches in all kinds of soil including moorum, stoney earth and earth mixed with boulders except sheet rocks and boulders including dressing of sides and leveling the bed up to the required depth and disposing the excavated materials away from the work site with initial lead and lift, including shoring, shuttering with cost of all labour, sundries & T & P etc. required for the work complete as directed by the Engineer in charge. |
| 23 | 0.00m to 1.5m |
| 24 | 1.5m to 2.0m |
| 25 | Filling in foundation, trenches and plinth with river sand, well watered and compacted, with top surface dressed and leveled to proper gradient including cost of all materials, conveyance, all taxes and royalties, loading and unloading, including cost of all labour, sundries, T & P etc. All complete as per directions of the Engineer -in-charge. |
| 26 | Façade |
| 27 | Filling available excavated earth (excluding rock) in trenches plinth sides of foundation etc. in layers not exceeding 20 cm in depth , consolidating each deposited layers by ramming and watering, lead up to 50m and lift up to 1.5 mt etc. including cost of all labour, sundries T & P etc complete in all respect as per the direction of Engineer-In-Charge. |
| 28 | Ground Floor |
| 29 | Disposal and carriage of surplus excavated earth/debries and lifting by mechanical means within 5 Km from work site and road side including loading, unloading and cost of all labour, T&P etc. Complete as per direction of the Engineer-in-charge. |
| 30 | Ground Floor |
| 31 | Providing and laying plain cement concrete of proportion (1:3:6) in foundation and floors using 4 cm. size black hard crusher broken granite stone metal and screened and washed sharp sand for mortar of approved quality and from approved quarry including hoisting, lowering, laying concrete, ramming, watering and curing etc. complete to required levels laid in layers not exceeding 15 cm. thick in each layer including cost, conveyance, royalties of all materials and cost of all labours,labour cess, T&P etc complete as per the direction of the Engineer-in-charge. |
| 32 | Ground Floor |
| 33 | Providing & applying of pre constructional anti-termit treatment by drilling 12mm dia holes at distance of 30cm @ junction of wall & floor about 300mm apart deep enough to reach the soil below & chemical emulsion (PREMISE, IMIDACHLOPRIED 30.5SC OF BAYER MAKE mixed with 47.5ltr water) pumped these holes to soak the soil 1 tr solution of each hole as per manufactures specification & the holes should be pluged the filling materials including cost of all materials, labour,conveyance, T&P, all taxes and hire charges of machinaries as per direction of Engineer-in-charge. (Make Hi-Solution pest control) services or equivalent). |
| 34 | Ground Floor |
| 35 | Fly Ash brick masonry in cement mortar (1:6) in foundation and plinth using Fly Ash bricks of 25 x 12x 8 cm size having a crushing strength of not less than 75 kg./sqcm with dimensional tolerance ± 2% including splays cutting circular moulding chamfering and corbelling and similar such type of works with all necessary projections watering and curing after immersing the bricks in water at least for six hours before use including cost, conveyance, royalties and taxes of all materials with all labour,labour cess and T & P required for the work complete in all respect as per direction of Engineer-in-Charge. |
| 36 | Ground Floor |
| 37 | Reinforced cement concrete of M-20 grade as per approved designs and drawings having a minimum compressive strength (in work test) of 200kg/cm2 in 15 cm cubes at 28 days after mixing and test conducted in accordance with I.S. 456 and I.S. 516 using 12 mm. to 20 mm. size black hard crusher broken granite chips (20 mm. size chips not to exceeds 25 % ) and screened and washed sharp sand for mortar of approved quality from approved quarry to be mixed in concrete mixture including hoisting, lowering, laying and compacting concrete by using vibrators, watering and curing for 28 days, centering and shuttering then after dismantling and removing debrises from the work site and finishing the exposed surface smooth providing grooves or beads wherever necessary including cost, conveyance, royalties and taxes of all materials and cost of all labours, sundries, T&P, required for the work etc. complete but excluding cost and conveyance of M.S. rods or Tor steel and binding wires and labour charges for straightening, cutting, bending etc. of M.S. rods or Tor steel tying the grills and placing in proper position as directed by the Engineer in charge. |
| 38 | Foundation Footing |
| 39 | Column Pedestal |
| 40 | Grade Beam |
| 41 | column |
| 42 | Roof Beam |
| 43 | roof slab |
| 44 | Reinforced cement concrete of M-25 grade as per approved designs and drawings having a minimum compressive strength (in work test) of 200kg/cm2 in 15 cm cubes at 28 days after mixing and test conducted in accordance with I.S. 456 and I.S. 516 using 12 mm. to 20 mm. size black hard crusher broken granite chips (20 mm. size chips not to exceeds 25 % ) and screened and washed sharp sand for mortar of approved quality from approved quarry to be mixed in concrete mixture including hoisting, lowering, laying and compacting concrete by using vibrators, watering and curing for 28 days, centering and shuttering then after dismantling and removing debrises from the work site and finishing the exposed surface smooth providing grooves or beads wherever necessary including cost, conveyance, royalties and taxes of all materials and cost of all labours, sundries, T&P, required for the work etc. complete but excluding cost and conveyance of M.S. rods or Tor steel and binding wires and labour charges for straightening, cutting, bending etc. of M.S. rods or Tor steel tying the grills and placing in proper position as directed by the Engineer in charge. |
| 45 | Foundation Footing |
| 46 | Column Pedestal |
| 47 | Plinth beam |
| 48 | column |
| 49 | Staircase |
| 50 | Lintel |
| 51 | Chhaja |
| 52 | Roof Beam |
| 53 | roof slab |
| 54 | First Floor |
| 55 | column |
| 56 | Staircase |
| 57 | Lintel |
| 58 | Chhaja |
| 59 | Roof Beam |
| 60 | roof slab |
| 61 | Terrace Floor |
| 62 | column |
| 63 | Lintel |
| 64 | Chhaja |
| 65 | Roof Beam |
| 66 | roof slab |
| 67 | Supplying Cutting, straightening coiled or bent up M.S. Rod or tor steel of primary steel producers such as SAIL / Tiscon / RINL / JINDAL STEEL / SHYAM STEEL (grade Fe-500D) etc. including bending, binding, welding and jointing if necessary and tying the grills and placing in position as required for R.C.C. Work and for providing fan hooks as required, hoisting, lowering, laying including cost, conveyances, taxes of M.S. Rod or tor steel and binding wires of 18 to 20 gauge and labour required for the work for bending, binding and tying the grills in all floors with labour cess etc. (payment will be made on standard weight of B.I.S. for M.S. Rods or tor steel only) etc. complete as per specification & direction of Engineer-in-charge. |
| 68 | Ground Floor |
| 69 | First Floor |
| 70 | Terrace Floor |
| 71 | Fly Ash brick masonry in cement mortar (1:6) in super structure using Fly Ash bricks of 25 x 12x 8 cm size having a crushing strength of not less than 75 kg./sqcm with dimensional tolerance ± 2% including splays cutting circular moulding chamfering and corbelling and similar such type of works with all necessary projections watering and curing after immersing the bricks in water at least for six hours before use including cost, conveyance, royalties and taxes of all materials with all labour,labour cess and T & P required for the work complete in all respect as per direction of Engineer-in-Charge. |
| 72 | 250mm wall |
| 73 | Ground Floor |
| 74 | First Floor |
| 75 | Second Floor |
| 76 | 120mm wall |
| 77 | Ground Floor |
| 78 | Providing 16 mm thick cement plaster with cement punning of mix (1:6) with screened and washed sharp sand for mortar and finished smooth to the rough surface of walls in all heights after racking out joints including watering and curing, rounding of corners, providing grooves where ever necessary with cost, conveyance, royalties of all materials with cost of all labour,labour cess, T&P, and scaffolding required for the work etc. complete in all respect as directed by the Engineer in charge. |
| 79 | Ground Floor |
| 80 | First Floor |
| 81 | Terrace Floor |
| 82 | 12mm thick cement plaster in cement mortar (1:4) finishing smooth to smooth surface of brick walls after raking out the joints including watering and curing, rounding of corners with cost, conveyance, royalties and taxes of all materials and cost of all labour, scaffolding, sundries and T&P. etc. required for the work etc. complete as directed by the Engineer in charge. |
| 83 | Ground Floor |
| 84 | First Floor |
| 85 | Second Floor |
| 86 | Terrace Floor |
| 87 | 6mm thick cement plaster to ceiling in cement mortar (1:4) including closed deep chipping with slurry treatment to the R.C.C. surfaces finished smooth including watering and curing, rounding of corners with cost, conveyance, royalties and taxes of all materials and cost of all labour, scaffolding, sundries and T&P. etc. required for the work etc. complete as directed by the Engineer in charge. |
| 88 | INSIDE |
| 89 | Ground Floor |
| 90 | First Floor |
| 91 | Terrace Floor |
| 92 | OUTSIDE |
| 93 | Ground Floor |
| 94 | First Floor |
| 95 | Terrace Floor |
| 96 | Providing and applying two coats of sika top seal-107 water proofing coating compound @3kn/sqm over terrace/Balconies/Basement on a cleaned dry and properly pre-wetted saturated surface including cost, conveyance of all materials, sundries, T&p all labour etc complete as per direction of engineer-in charge . |
| 97 | First Floor |
| 98 | Providing 2.5cm thick Grading Concrete over roof slab with cement concrete (1:2:2) using 6mm size black hard granite crusher broken chips and screened & washed sharp sand for mortar and finished smooth to the rough surface of slab including watering and curing with cost, conveyance, royalties of all materials with cost of all labour, labour cess and T&P required for the work etc. complete in all respect as directed by the Engineer in charge. |
| 99 | First Floor |
| 100 | Terrace Floor |
| 101 | Supplying, fitting and fixing vitrified industrial floor tile 30x30cm premium grade 8 to 10 mm thick in floors of approved make confirming to IS : 4457 laid on 20mm thick C.M (1:4) & filling joints with white cement of approved quality including cost of all materials, takes labour T&P etc required for the work. |
| 102 | Supplying, fitting and fixing vitrified floor tile 600mm X 600 of approved shade and make (Single Charge) in floors of approved make confirming to IS : 13755 laid on 20mm thick C.M (1:4) & spacer of 4 mm for grouting the joints of flooring tiles having joints of 4 mm width, using epoxy grout mix of 0.70 kg of organic coated filler of desired shade (0.10 kg of hardener and 0.20 kg of resin per kg), including filling / grouting and finishing including cost of all materials, takes labour T&P etc required for the work. per 1 sqm (Data for 10 sq.mt.) |
| 103 | Ground Floor |
| 104 | First Floor |
| 105 | Supplying, fitting and fixing vitrified tile 600mm x 600mm of approved shade and make (Single Charge) in wall of approved make confirming to IS : 13755 laid on 20mm thick C.M (1:4) & spacer of 4 mm for grouting the joints of flooring tiles having joints of 4 mm width, using epoxy grout mix of 0.70 kg of organic coated filler of desired shade (0.10 kg of hardener and 0.20 kg of resin per kg), including filling / grouting and finishing including cost of all materials, takes labour T&P etc required for the work. per 1 sqm (Data for 10 sq.mt.) |
| 106 | Ground Floor |
| 107 | First Floor |
| 108 | Second Floor |
| 109 | Fixing granite tiles of approved dimension area above 0.4 sqm (20mm thick) in floor, treads of steps and landing on 20mm thick bed of cement mortar (1:4) jointed with neat cement slurry mixed with pigment to match the shades of the tiles including rubbing and polishing etc. complete with cost, conveyance, royalties of all materials complete in all respects as per direction of Engineer-in-Charge. |
| 110 | Ground Floor |
| 111 | First Floor |
| 112 | Fixing granite tiles of approved dimension area above 0.4 sqm (20mm thick) in dado on 20mm thick bed of cement mortar (1:4) jointed with neat cement slurry mixed with pigment to match the shades of the tiles including rubbing and polishing etc. complete with cost, conveyance, royalties of all materials complete in all respects as per direction of Engineer-in-Charge. |
| 113 | Ground Floor |
| 114 | First Floor |
| 115 | Fixing Khandolite Stone of approved dimension area above 0.4 sqm (20mm thick) in Walls, treads of steps and landing on 20mm thick bed of cement mortar (1:4) jointed with neat cement slurry mixed with pigment to match the shades of the tiles including rubbing and polishing etc. complete with cost, conveyance, royalties of all materials complete in all respects as per direction of Engineer-in-Charge. |
| 116 | Factory made solid WPC door frame of size 95mmX55mm fabricated. The door frame consist of four segments which are provided with plug-in-socket arrangement in situ in the mould. The segments are plugged in and are joined together by means of screw. The WPC frame shall be provided with the material and process for manufacturing the door frames shall confirm to relavent i s specification. The finish of door frame will be plain colour white/ivory/beige/light gray/golden brown/mahogany/teak wood/sand stone/champagne/pastel blue or any other colour using high quality pigments complete in all respect as per specification and direction of the Engineer in charge. |
| 117 | Ground Floor |
| 118 | First Floor |
| 119 | Supplying, fitting and fixing of 32mm thick flush door shutter with approved quality of 30mm thick BWR block board pasted with 1mm thick sunmica on both side of approved design and quality including cost of all door fittings and fixtures etc complete. |
| 120 | Ground Floor |
| 121 | Providing and fixing of Fixed Glazing with part Top hung of approved make to be fabricated from roll formed sections made of pre-painted steel (base steel as per IS-513 of 0.6mm thick \\"D\\" quality galvanized as per IS-277 with zinc of 120 Gm/sqm)(FIXED GLAZING WITH PART TOP HUNG) |
| 122 | Ground Floor |
| 123 | Supplying, fitting and fixing of two track UPVC sliding window of approved make with 6mm thick glass of approved quality complete with frame shutters and all fitting and fixtures. |
| 124 | Ground Floor |
| 125 | Supplying, fitting & fixing in all floors of M.S. grills, grill gates, M.S. gates, garage door, collapsible gates with top and bottom rails, steel windows, critical frames for windows, stair case and parapet railing made out of M.S Square bar/ flat including stair case hand railing with 40mm. dia G.I.pipe etc. including painting two coats over a coat of redoxide primer as per approved drawing and design with cost of all materials & labour, labour cess, T&P, sundries etc. complete in all respect as per specification & direction of the Engineer-in-Charge. |
| 126 | Supplying, fitting and fixing of Stainless steel of 304 grade in hand railing using 50mm dia of 2mm thick circular pipe with Balustrade of size 32mm x 32mm x 2mm @ 0.90mtr. C/C and stainless square pipe bracing of size 32mm x 32mm x 2mm in 3 rows in stair case as per approved design and specification, buffing, polishing etc with cost, conveyance, taxes of all materials, cost of all labour,labour cess, T&P etc. required for the work complete in all respect as per direction of the Engineer-in-charge. |
| 127 | Providing,painting two Coats of approved shade of PU enamel paint of BERGER make as approved by Consultant over one coat of primer on new iron work finished smooth including all cost,conveyance, taxes,sundries,T&P and all labour etc, complete as per direction of engineer in charge . |
| 128 | Ground Floor |
| 129 | Painting two coats to new Iron work with approved enamel paints of approved colour, shade over a coat of primer including sand papering, polishing the surface, cost, conveyances, taxes of all materials and cost of all labour,labour cess with T&P etc, complete as per specification & direction of Engineer-in-charge. |
| 130 | Ground Floor |
| 131 | First Floor |
| 132 | Terrace Floor |
| 133 | Priming one coat with wall (water bound) to make an even finished surface in all floors and heights to wall surface of approved make and shade including sand papering, applying putty wherever necessary & cost of scaffolding, staging charges with cost, conveyance, cost of all labour,labour cess T&P etc. complete as per the direction of the Engineer-in-charge. |
| 134 | INSIDE |
| 135 | Ground Floor |
| 136 | First Floor |
| 137 | Terrace Floor |
| 138 | OUTSIDE |
| 139 | Ground Floor |
| 140 | First Floor |
| 141 | Second Floor |
| 142 | Wall painting two coats with Weather coat paint (1st quality) exterior grade of approved make & approved shade to make an even finished surface in all floors and heights with all scaffolding and staging charges including cost, conveyance, cost of all labours, T & P, sundries etc. as required for the work complete in all respect as per the direction of the Engineer-in-Charge. |
| 143 | Ground Floor |
| 144 | First Floor |
| 145 | Second Floor |
| 146 | Finishing wall surface of walls with Acrylic wall putty (Water based) of approved make and finished smooth and even surface to receive painting including cost of scaffolding staging charges with cost of all materials taxes, labour T&P etc complete. (per one Sq. Mtr.) (Data for 10 sqm.) INCLUDING COST OF material &Labour. |
| 147 | All Floor |
| 148 | Painting two coats with plastic emulsion paint to make an even finished surface in all floors and heights to wall surface of approved make and shade including sand papering, applying putty wherever necessary & cost of scaffolding, staging charges with cost, conveyance, cost of all labour,labour cess, T&P etc. complete as per the direction of the Engineer-in-charge. |
| 149 | Ground Floor |
| 150 | First Floor |
| 151 | Terrace Floor |
| 152 | Finishing walls with water proofing cement paint of approved shade on new work TWO coats to give an even shade including cost of brushes and putty including cost of paint. |
| 153 | Plinth Protection |
| 154 | Cement concrete of proportion (1:2:4) in foundation and floors using 40mm. size metal including cost of all materials labour,T&P required for the work etc complete. |
| 155 | Supplying and fixing of Wall paneling made of aluminum anodised section framing conforming to standard Aluminium sections as horizontal and vertical members with atleast 600mm c/c and fixing of 9mm thick BWR ply with 4mm thick veneer pasting finished with melamine polishing complete. (SOR - 2022,P No.234,Sl No.25.17(6)) |
| 156 | Ground Floor |
| 157 | Supplying, fitting and fixing of grid mineral fibre ceiling board having size 600 mm x 600 mm x 16mm of approved design and quality complete with frame and all fitting and fixtures. (SOR - 2022,P No.235,Sl No.25.17(14)) |
| 158 | Ground Floor |
| 159 | Providing & fixing false ceiling of Alm anodised T section no 3215 with 2'-0\\" center to centre,L section no 1705 up to 15 micron on 4 walls to be fixed by means of steel screw and PVC plug and the Alm grid 2'-0\\"x2'-0\\" with 12mm thick prelaminated Particle Board. |
| 160 | Ground Floor |
| 161 | Supplying and fixing of Elastomeric Membrane of 200mm x 2mm size for expansion joint sealing from approved manuefacturer, Tixing with epoxy adhesive of approved quality complete. (SOR - 2022,P No.234,Sl No.25.17(11)) |
| 162 | Ground Floor |
| 163 | Supplying and fixing of Roller blinds by fixing powder coated top channel, bottom channel with bottom end cap, control unit and good quality of 0.60 mm thick fabric of approved design and quality etc. complete. (SOR - 2022,P No.234,Sl No.25.17(6)) |
| 164 | Ground Floor |
| 165 | Providing and fixing double scaffolding system (cup lock type) on the exterior side of building/structure, upto 25 metre height, above ground level, including additional rows of scaffolding in stepped manner as per requirement of site, made with 40mm dia M.S. tube, placed 1.5 metre centre to centre, horizontal & vertical tubes joint with cup & lock system with M.S. Tubes, M.S. tube challis, M.S. clamps and staircase system in the scaffolding for working platform etc. and maintaining it in a serviceable condition for execution of work of cleaning and/ or pointing and/ or applying chemical and removing it thereafter.The scaffolding system shall be stiffened with bracings, runners, connecting with the building etc, wherever required, if feasible, for inspection of work at required locations with essential safety features for the workmen etc., complete as per directions and approval of Engineer-in-charge.Note:- (1) The elevational area of the scaffolding shall be measured for payment purpose. (2) The payment will be made once only for execution of all items for such works. |
| 166 | Ground Floor |
| 167 | Dormakaba automatic Sliding door operator ES 250 PRO Easy 4150 mm with low-noise drive motor without gearbox, TÜV design tested for 1.5 Million Cycle of operation in accordance with low voltage guidelines of IEC /EN 60335-2-103 and fulfils EN 16005 and DIN 18650-1 / DIN 18650-2 standards. With the clear passage width up to 2000 mm. The Profile Finish should be Silver Anodized E6/C0, with operator dimensions (H x D) : 100 x 180 mm. Drive with acoustically decoupled and exchangeable running rail and wear-resistant special surface. Rollers made of special plastic, Counter rollers as derailment protection. Mounting plate with prefabricated fixing holes and threaded holes. Microprocessor-controlled control unit, Self-learning, with adjustable parameters for opening and closing speed, hold-open time 0- 180 Sec, with smps, Class of protection IP 20.Program Switch with Knob, ES 250 PRO Easy, Maximum Panel Weight Carrying Capacity of 2X 125 Kgs & 1X 125 kgs each leaf. The Max. opening and closing force by the operator should not exceed 150N and maximum power consumption should not exceed 130W during operation mode. The operator should be equipped Nemo Combi sensor with 2x Microwave for activation and double rows of 24 spots failsafe Safety infrared curtains without the need of Photocell. The system shall have constant power supply 230V+ 5%, 50Hz, AC. |
| 168 | EI PARTRecessed extra lead sub main wiring in 2 X 1.5sq.mm + 1 X 1.5sq.mm PVC insulated single core multistrand copper conductor of ISI marked conforming to IS-694/1990 in the following mm dia non-metallic heavy duty flexible conduit 1.6 mm thick along with the following sq.mm FR PVC insulated single core multistrand copper conductor as earth wire as required.(Make of wire-Finolex/ L&T/ Anchor/ Havells/ V-Guard/ HPL or equivalent). |
| 169 | Recessed wiring to submain in the following sq.mm FR PVC insulated single core multistrand copper conductor of ISI marked conforming to IS-694/1990 in the following mm dia non-metallic heavy duty flexible conduit 1.6 mm thick along with the following sq.mm FR PVC insulated single core multistrand copper conductor as earth wire as required.(Make of wire-Finolex/ L&T/ Anchor/ Havells/ V-Guard/ HPL or equivalent). |
| 170 | 2 X 2.5 sq.mm +1 X 1.5 sq.mm -do- |
| 171 | S/ F of maintenance free Chemical earthing size of earth bar 3 mtr long, 17mm dia made with steel core and copper exterior, chemical compound with suitable proportionate of 50kg and including all accessories as per the direction of Engineer-in-charge. |
| 172 | Extra copper flat 25 X 5mm (Electrolytic Grade (Cu-ETP) (Grade: C 101), coated with Tin and annealed) |
| 173 | Supply and fixing of different type of light fittings. |
| 174 | Supply and Fixing of 24watt recess LED Square (1' x 1') light fitting. (Make- Havells/ Phillips/ Bajaj/ Crompton or equivalent). as per the direction of Engineer-in-charge. |
| 175 | Supply of PVC armored cables ISI marked.(Make- Glowstar/ Polycab/ Nicco/KEas per letter No.309 19.01.2011 of SEEC (R&B) Odisha |
| 176 | 6sq.mm 2core |
| 177 | 10sq.mm 4core |
| 178 | Cable layingTrenching with sand spreading and bricks laying and laying of cable in trench in 2 1/2' depth .pvc cable upto 25sqmm |
| 179 | Supply and fixing of following way single pole and neutral sheet steel MCB distribution board 250V on surface/recess complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, detachable gland plate, interconnections, phosphatized and powder painted including earthing etc. as required (but with out MCB/ RCCB/ Isolator) (Make-Legrand/ Hager/ Simens/ schneider or equivalent). |
| 180 | 8way TPN DD DB |
| 181 | Supply and fixing of 0.5Amp to 32A rating 240 V \\"C\\" series MCB suitable for lighting and other loads of the following poles in the exiting MCB DB ISI marked complete with connections testing and commissioning etc. (Make-HPL/ Havells/ Legrand / L&T/ ABB or equivalent). |
| 182 | 32Amp rating (DP) MCB |
| 183 | Supply and fixing of Four pole MCCB with Extented handle and Spreader terminal . (Make- L&T/ Legrand/ ABB or equivalent). |
| 184 | 63Amp 4pole (25KA) |
| 185 | Recessed wiring to light point/Fan point/ Exhaust fan point/Call bell point with 1.5 sq.mm FR PVC insulated single core multistrand copper conductor of ISI marked with 20 mm dia non-metallic PVC flexible conduit with 6Amp, 250V Modular switch ISI marked and ceiling rose ISI marked mounted on metal box having front Modular cover of suitable size, metal box with 1.5 sq.mm FR PVC insulated single core multistrand copper conductor as earth wire including all accessories and connection. (Make of wire-L&T/ Anchor/ Havells/ V-Guard/ Great White/ HPL or equivalent). |
| 186 | Group-B L.P- 13 F.P- C.B.P- |
| 187 | Group-C L.P- 12 F.P- C.B.P-0 |
| 188 | Supply and fixing of 6Amp plug with 6Amp switch on existing board. (Modular type)(Make-Great white/ Legrand / ABB/ Roma/ Havells/ HPL/ Cona or equivalent). |
| 189 | Supply and fixing of Modular metal box on surface or in recess with suitable size of Modular cover in front including providing and fixing of 6pin 6Amp & 16Amp socket outlet and 16Amp Modular switches including all connection. (Make-Great white/ Legrand / ABB/ Roma/ Havells/ HPL/ Cona or equivalent). |
| 190 | Supply and fixing of Modular switch, Socket, T.V Socket and Telephone socket etc. (Make-Great white/ Legrand / ABB/ Roma/ Havells/ HPL/ Cona or equivalent). |
| 191 | 32Amp Modular DP switch |
| 192 | Supply and Fixing of 2.0 Ton 3 star Fixed split type A.C machine.Make :-Voltas/ Carrier/ Havells (Lloyd)/ Daikin or equivalent. as per the direction of Engineer-in-charge. |
| 193 | S/F of 5 KVA Votage stabiliser.Make :- (Leotronics /V-guard/ Microtech or equivalent). as per the direction of Engineer-in-charge. |
| 194 | S/F of Extra Copper pipe with Nylon Insulation |
| 195 | S/F of Drainage pipe . |
| 196 | S/F of Angle frame . |
| 197 | S/F of Cord wire for A.C machine |
| 198 | S/F of 16 AMP 3 pin top . Make :- ( Anchor/ Cona ) |
| 199 | S/F of 63Amp 4way Connector |
| 200 | SITC of LED Track Light : Power : 15W CCT: 3000K/4000K/5000K optional Beam Angel :24°/34°/60° optional input Voltage: 200-240V AC Control : on-off < IP20. |
| 201 | SITC of 3wire surface mounted trak for above track light. |
| 202 | SITC of mounting accessories, Live end cap , L connector , Straight connector etc for succsfull instation of track and light. |
| 203 | Supply and laying of PVC Copper unarmoured flexible FRLS insulated multicore cable 1100V grade confirming to IS694 size 3CX1.5 sq mm. Make:SBEE, KEI, Polycab, Walna |
| 204 | Supply and laying of PVC Copper unarmoured flexible FRLS insulated multicore cable 1100V grade confirming to IS694 size 3CX2.5 sq mm. Make:SBEE, KEI, Polycab, Walna |
| 205 | SITC of Direct Lighting Distribution Board with TPN incomer of suitable rating and outgoing SP MCBs of suitable rating Make : Canara, ABB, Havells |
| 206 | Other accessories like junction Boxes, nuts bolts clamps, condutis etc required for complete installation of the system |
| 207 | LED Signage- Acrylic Letter with LED modules letter raised wall should be non transparant, including scaffolding, fitting, fixing etc in direction of Engineer in Charge |
| 208 | PH PARTSupplying all materials, labour, T&P and cutting holes through existing brick work including making good the damages in cement mortar (1:4) for taking GI pipes and fittings/ PVC pipes and fittings etc all complete as per PH specification and direction of the Engineer in charge. |
| 209 | Supplying all materials, labour, T&P and fitting and fixing U-PVC SWR pipes (Type-A) and fittings of the following outside diameter conforming to ISI No. 13592/1992 to walls with nails, bobbins and wooden plugs or laying in trenches including jointing with supply of approved rubber lubricant by non-heat application method/as per manufacturer’s specification, testing, earthwork in excavation in all kinds of soil and refilling of trenches as per specification and direction of the Engineer in charge |
| 210 | 110mm dia U-PVC SWR pipe (Supreem/Ashirvad) (Type-A) |
| 211 | 110mm U-PVC Door Bend |
| 212 | 110mm U-PVC plain Bend |
| 213 | 110mm dia PVC SWR Clamp/Clip. |
| 214 | Supplying all materials, labour, T&P and constructing gully trap chamber of the following inside size with 8cm thick R.C.C precast cover slab in cement concrete (1:2:4) mix using 12mm size h.g chips, foundation concrete (1:4:8) using 40mm size hard granite metal on bed and around trap, K.B brickwork in c.m (1:6) in F&P and inside 12mm thick cement plastering (1:3) finished with a floating coat of neat cement including fixing 100mmx100mm size HCI gully trap,150mmx150mm size C.I grating etc all complete as per approved drawing, specification and direction of the Engineer in charge |
| 215 | Gully trap chamber of size 250mmx250mm with R.C.C cover slab |
| 216 | Supplying all materials, labour, T&P and constructing inspection chamber of the following size with cement concrete(1:3:6) using 40mm size hard granite metal on bed, 1st class K.B brickwork in cement mortar(1:6),moulding and shaping the channel inside and benching with cement concrete (1:2:4) using 12mm size h.g chips,12mmthick cement plaster (1:3) with punning to inside, cement flush pointing (1:3) to outside, R.C.C cover slab in (1:2:4) using 12mm size h.g chips with RCC man hole cover, earthwork in excavation in all kinds of soil and refilling the cavity around the chamber including watering, curing, conveyance of all materials to worksite, payment of royalty, taxes etc all complete as per approved specification and direction of the Engineer in charge |
| 217 | Construction of Inspection chamber Inside size 760mmx760mmx460mm |
| 218 | Reconstruction of Inspection chamber Inside size 760mmx760mmx460mm |
| 219 | R.C.P.C.Cover (18\\" round) |
| 220 | Supplying all materials, labour, T&P and constructing man hole chamber of the following size with cement concrete(1:3:6) using 40mm size hard granite metal on bed, 1st class K.B brickwork in cement mortar(1:6), moulding and shaping the channel inside and benching with cement concrete (1:2:4) using 12mm size h.g chips,12mmthick cement plaster (1:3) with punning to inside, cement flush pointing (1:3) to outside, R.C.C cover slab in (1:2:4) using 12mm size h.g chips with RCC man hole cover, earthwork in excavation in all kinds of soil and refilling the cavity around the chamber including watering, curing, conveyance of all materials to worksite, payment of royalty, taxes etc all complete as per approved specification and direction of the Engineer in charge |
| 221 | Reconstruction of Manhole chamber Inside size 910mmx910mmx910mm |
| 222 | R.C.P.C.Cover (18\\" round) |
| 223 | Supplying all material, Labour, T&P, Laying in trenches (to level or slope) on plasticized PVC pipes confirming to IS: 4984/2016 of the following outside dia for pressure rating PN-6 including jointing with supply of approved solvent cement by non hit application method as per manufacturers specification, provinding and laying in trench cement concrete (1:4:8) with 40mm size hard granite metal in the type c1 standard bedding surrounding or encasing including concrete for bedding and curing etc all complete as per PH specification and direction of Engineer-In-Charge |
| 224 | 110mm dia u-PVC pipe arround Concrete |
| 225 | Supplying all materials, labour, T&P and cleaning and removal of sludge & sealed from choked inspection chamber/man hole chamber/ sewer line/septic tank by engaging sweeperusing bamboo and disposing sewage at a safe distance all complete as per direction of the Engineer in charge. (Item Reference to H & U.D. Department P.H & P.W. Analysis Page No.13,Item No.155) (a) |
| 226 | Supply and Installation of small fountain of 6' Dia, including Nozzle, Ball joint, Bush, Led light, Pump, Led controler, Driver, Remote, Transportation and Installation |
| 227 | FIRE FIGHTINGSupply, Installation, Testing and commissioning manual call point , MCP ( make- RAVEL ) |
| 228 | Supply ,Installation ,Testing and Commissioning Hooter ( make- RAVEL) |
| 229 | Supply ,Installation, Testing and commissioning Smoke Detector ( make- RAVEL ) |
| 230 | Supply ,Installation, Testing and Commissioning 02 zone fire alarm conventional panel ( make- RAVEL) |
| 231 | Supply and Installation 1.5sqmm 2core FRLS Armoured cable with conduit ( make- Polycab/ KEI ) |
| 232 | 12volt 7ah Battery ( make- Exide ) |
| 233 | New ABC Type Fire Extinguisher ISI Mark 6kg ( make- FIRE SHIELD ) |
| 234 | New CO2 Type Fire Extinguisher ISI Mark 4.5kg ( make- FIRE SHIELD ) |
| 235 | Fire Bucket 4pic + Fire Bucket Canopy Type Stand Set Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Jul 27, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedAug 10, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 9 daysAug 13, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 12 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender