Defence Statutory Bodies & Commissions/Committees Closing in 2 days TDR #56689965

Tender For special Repair / Replacement Of Bldg No T-29 Of Living (Malta Line), Toilet Block No P-21 And T-4-5 Bd (Kandhar Line) Incl B/R & E/M Wks At 105 Inf Bn (Ta) Raj Rif Under Ge (Central) Delhi Cantt-10

Issued by Statutory Bodies & Commissions/Committees · New Delhi, Delhi
Tender Value
48.54 Lakhs
Estimated cost
Bid Submission
17 Aug 2026
2 days left
EMD
97080
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
New Delhi → Delhi
EMD Exemption
Available
Quantity
Not Available

Project Description

Tender for special Repair / Replacement Of Bldg No T-29 Of Living (Malta Line), Toilet Block No P-21 And T-4-5 Bd (Kandhar Line) Incl B/R & E/M Wks At 105 Inf Bn (Ta) Raj Rif Under Ge (Central) Delhi Cantt-10

BOQ

Name of Work:- SPL REPAIR / REPLACEMENT OF BLDG NO T-29 OF LIVING (MALTA LINE), TOILET BLOCK NO P-21 AND T-4-5 BD (KANDHAR LINE) INCL B/R & E/M WKS AT 105 INF BN (TA) RAJ RIF UNDER GE (CENTRAL) DELHI CANTT-10
Sl. No. Item Description
1Taking down cement plaster of any description on brick stone or concrete walls surfaces including raking out joints hacking for keys scrubbing down with water etc incl remove all debris in 2 KM form site complete all as specified and directed.
2M&L for 15 mm thick rendering in cement mortar on fair faces of brick work or concrete surfaces, in cement mortar (1:4 ) mixed finished even and fair etc complete all as specified and directed.
3M&L Rendering 15 mm thick in CM 1:6 on other than fair faces of brick work or concrete surfaces finished even and fair without using extra cement complete all as specified.
4M&L for preparation of newly plastered surfaces of walls and providing and applying putty of 1 mm thickness over plastered surface to prepare the surface even and smooth and finishing walls with Acrylic Smooth exterior paint of required shade : New work (Two or more coat applied @ 1.67 ltr/10 sqm over and including priming coat of exterior primerapplied @ 2.20 kg/10 sqm) complete all as specified as directed by Engr-in-charge.
5M&L for Preparation of new surfaces (Plastered or un-plastered) of walls and applying two coats of oil bound distemper complete all as specified.
6Dismantling water tanks and removing to store of 1000 Ltr Capacity
7M&L for rotational moulded polyethylene water storage tanks white colour 500 lts capacity, triple layered (cylindrical vertical with closed top) hoisted and fixed in position including 20 mm dia PTMT float valve, lid tank cover for polyethylene and polyethylene balldescription including fitting and fixtures complete all as specified. (ISI Marked)
8Demolition of brick work built in cement or cement lime mortar of any description including quoins,arches,pillars,etc., all as directed.
9M & L for brick work with Cement Mortar1:6 using sub class 'B' bricks, old size , straight or curved on plan exceeding 6 m mean radius all as specified and directed.
10Material and labour for brick work with sub class B bricks of old size, straight or curved on plan exc 6m mean radius in half brick walls, in CM 1:4 complete all as specified and directed.
11Dismantling of wall and ceiling/cup board board fibre pulp AC boards etc any thickness including cover fillets removing the wiring
12M and L Providing & Fixing False ceiling with semi perforated 12mm thcik micro tegular edged at all heights with GRG (Glass Fibre reinforced Gypsum) false ceiling tiles for temp buildings/PMT Bldgs of size 595x595mm of approved texture, design and pattern having moisture content less than 2%,humidity resistance of 99%, NRC0.50 to 0.75 as per IS 8225:1987, Noncombustible as per BS 476 (part-4)-1970 and light Code Description unit rate No 429 SUB HEAD :26.0 NEW TECHNOLOGIES AND MATERIAL reflectance of 85% minimum to be laid in true horizoatal level suspended on interlocking metel T-Grid of hot dipped galvanised iron section of 0.33mm thick (galvanised @ 120 grams oer sqm including both sides) comprising of main-T runners of size 15x32mm of length 3000mm, vross-T of size 15x32nn of lenght 1200mm amd secondry itermediate cross-T of size 15x32 of lenght 600mm to form grid module of size 600x600mm, suspended from ceiling using galvanised mild steel items (galvanising @ 80 grams per sqm) ie. 50mm long, 8mm outer diameter M-6 dash fasteners or 3 to 4 mm GI hanging wire for temp Bldg length/ht as per site req ,6mm dia fully threaded hanger rod upto 1000mm length and L-shape level adjuster of size 85x25x2mm.Galvanised iron perimeter wall angle of size 24x24x0.40 mm of length 3000mm to be fixed on perimeter wall/partition with the help of plastic rawl pluhs at 450mm center to center and 40mm long dry wall screws. The work shall be carried out as per specification, drawing and as per direction of the Engineer-incharge.
13Taking down chowkhat or frame not exceeding 1.5 sqm each with shutter (without taking off shutter from the frame)
14Taking down chowkhat or frame exceeding 1.5 Sqm each and not exceeding 4 Sqm each sqm each with shutter (without taking off shutter from the frame)
15S&F Providing and fixing factory made single extruded WPC (Wood Polymer Composite) solid decorative type flush door shutter of size 35 mm thick comprising of virgin polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibres (wood powder/ rice husk/wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) having minimum density of 650 kg/cum and screw withdrawal strength of 1800 N (Face) & 900 N (Edge), minimum compressive strength 50 N/mm2 , modulus of elasticity 850 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant. WPC to be laminated with PVC foil of minimum 14 microns thick of approved design pasted with hot melt adhesive on both faces of shutter and fixing with stainless steel butt hinges of required size with necessary full body threaded star headed counter sunk S.S screws, all as per direction of EngineerIn- Charge. (Note: stainless steel butt hinges and necessary S.S screws shall be paid separately)complete all as specified and directed.
16Providing and fixing factory made single extruded WPC (Wood Polymer Composite) solid decorative type Skelton door shutter of size 35mm thick comprising of virgin polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/ wheat husk) and nontoxic additives (maximum toxicity index of 12 for 100 gms) having minimum density of 650 kg/cum and screw withdrawal strength of 1800 N (Face) & 900 N (Edge), minimum compressive strength50 N/mm2, modulus of elasticity 850 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant. WPC to be laminated with PVC foil of minimum 14 microns thick of approved design pasted with hot melt adhesive on both faces of shutter and fixing with stainless steel butt hinges of required size with necessary full body threaded star headed counter sunk S.S screws, all as per direction of Engineer-in-Charge. (Note: stainless steel butt hinges shall be paid separately under relevant item).Note:- Contractor will provide manufacturer test certificate alognwith screw out test certificate.
17S&F Pressed steel frames for doors with one or more rebates including necessary fixing lugs, hinges, lock strike plate, etc., complete as specified,size 105x60mm all as specified
18S&F Pressed steel frames for doors with one or more rebates including necessary fixing lugs, hinges, lock strike plate, etc., complete as specified,size 165x60mm(double frame)
19Supply and fixing factory made uPVC white colour Three track panels sliding door with fly proof S.S wire mesh (two Nos, glazed & one no. wire mesh panels) made of (big series) frame 116x45mm & sash 46x82mm both having wall thickness of 2.3+_ 0.2mm and single glazing bead/double glazing bead of appropriate dimension. (Area of door above 2.00sqm upto 5sqm comprising of upvc chamfbered frame, with in built roller track and sash extruded profiles duly reinforced woth 1.60+_ 0.2mm thick galvanised mild steel section maid from roll forming process of required length (shape & size according to upvc profile) Appropriate dimension oupvc extruted glazing beads, uPVC extruted interlock and uPVC extruded line sash adaptor (if required), EPDM gasket, wool pile, zinc alloy(white powder coated) handle with key on one side of extreme panels alongwith zinc plated mild steel multi point looking having tansmission gear with keeps, zinc alloy (white powder coated) cresent lock (if required). stainless steel (SS 304 grade) body with adjustable double nylon rollers (weight bearing capacity to be 120kg) GI fastners 100X8mm size for fixing frame to finished wall and necessary stainless steel screws etc. profile of frame & sash shall be mitred cut and fusion welded at all corners, including drilling of holes for fixing hardware and drainage of water etc. after fixing frame the gap between frame and adjacent finished wall shall be filled with weather proof silicon sealent over backer rod of required size and of approved quality, complete all as specified and dirtected by engineer-in charge. (Glass or wiremesh shall be paid separately) Note: For uPVC frame and sah extruded profiles minus 5% tolerance in dimension i.e. in depth & width of profile shall be acceptable. Variation in profile dimension in higher side shall be acceptable but no extra payment on this account shall be made.
20Powder coated aluminium (minimum thickness of powder coating 50 micron) for shutters of doors, windows & ventilators including providing and fixing hinges/ pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber/neoprene gasket required (Fittings shall be paid for separately) with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS:1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing/ paneling, C.P. brass/ stainless steel screws all complete as per architectural drawings and the directions of Engineer-in-charge
21S & F mild steel framed work such as grills, gratings, etc, with ends of bars shouldered and/or riveted, or forged into spikes, framed guard bars, barred iron doors, ladders framed balusters, walk ways, railings, framework of water tanks and similar work including aldrop and hinges holdfast etc conforming to Fe 290. Gde-E-165.
22S&F MS butt hinges medium weight 100 mm size fixed with MS screws.
23S&F aluminium anodised barrel tower bolt extruded section 150 mm long and fixed with MS screws.
24S&F 150 mm extruded aluminium alloy handle anodised fabricated type and fixed with mS screws.
25S&F 300 mm extruded section aluminium alloy anodised, sliding door bolt with hasp and staple and fixing clip of sheet and fixing bolt and nut.
26S&F for 300 mm MS ordinary rat tail rod pattern spring including roller and roller plate complete fixed on wooden frame or on wall with wooden plugs and set in cement mortar all as directed.
27M&L preparation of new or previously untreated steel and iron surfaces of any description over 10 cm width or girth and applying two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified
28M&L preparation of Old or previously untreated steel and iron surfaces of any description over 10 cm width or girth and applying two coats of synthetic enamel paint complete all as specified
29M & L for preparation of Old or previously untreated wooden surfaces of any description, not otherwise described, over 10 cm width or girth and applying two coats of synthetic enamel paint complete all as specified
30M&L for two coat cement base paint over a coat of alkali resist priming paint including preparation of wall surface complete all as directed by Engineer-in-Charge.
31M&L for three coat of white wash including preparation of wall surface complete all as directed by Engineer-in-Charge.
32S & F stainless steel wire cloth 0.36 mm nominal dia of wire and average width of aperture 1.40 mm complete all as specified and directed.
33S&F in repair stainless steel sink with drainage board made out of 1mm thick sheet for kitchen with plug, washers, waste pipe, waste coupling incl fixing cast iron cantilever bracket connecting union over all size 915x460mm with bowl size410x330x160mm complete all as specified and directed by Engineer-in-Charge.
34Taking up or down steel tubing and connections, including cleaning for re-fixing, bore of tubing 15mm
35All as per item No. 34 above but 20 mm bore .
36All as per item No. 34 above but 25 mm bore .
37Supplying and laying 15 mm dia of CPVC pipes SDR 11 & Plain CPVC SDR 11 fittings on walls/ceiling or laying in floors complete all as specified complete all as directed
38All as per item No. 37 above but 20 mm dia
39All as per item No. 37 above but 25 mm dia
40S & F Floor door stopper 150mm size of aluminium alloy body and tongue, anodised, with hard drawn steel spring, fixed in floor all as directed.
41Supply and fix vitreous China wash hand basin (pedestal) white of size 550X400mm excluding taps, waste chain and plug and porcelain stopper and waste pipe & waste coupling including all necessary fitting and fixtures complete all as specified
42S & F in repairs 15 mm dia 600mm long PVC connections with brass check nut complete Make Polytuff/symet or equivalent
43S&F in repairs bib taps 15 mm bore chromium plated brass, fancy type, with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule.
44S&F in repairs angle valve, fancy type, chromium plated brass, 15mm, complete all as directed.
45S&F in repairs looking mirror of size 600mmx450mmx5.5mm thick with aluminium frame selected quality mounted on 6mm thick commercial plywood and fixed to wooden plugs with chromium plated brass screws and cup washers.
46Demolition of stone slab and tiles of any description or thickness in floor apron etc complete all as specified and directed.
47S & F for Non - skid Ceramic tiles 7 to 8 mm thick area of each tile exceeding 0.18 sqm but not exceeding 0.38 sqm in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match to 10mm thick (1:4) CM Screed bed
48All as per item no. 44 except on vertical surfaces as in skirting etc over 10mm thick backing coat in CM 1:4, set and jointed in white cement with pigment to match all as specified and directed.
49M&L for Glazed ceramic tiles in vertical surface 350x 250x 7 mm/ 450X 350X 7mm thick set and jointed in neat cement slurry and pointed in white or colour cement to match including 10mm thick rendering in cement mortar (1:6) complete all as specified and as directed.
50M&L for 18-20 mm Granite (any type) work (table rubbed and polished) in steps,jambs,pillars window-cill,cooking platforms and incl 15mm thick screed bed in CM 1:6 using marble dust with admixture in CM (1:4) with pointing and white cement (1:2) of pigment to match with shade of granite all as spd.
51M&L for machine cut polished Machine cut Kota stone 20-25mm thick as in floor, tread, riser, pillar fixed with neat cement slurry over backing coat of 20mm thick in CM (1:4) including rubbing and polishing complete all as specified.
52Dismentling asbestos cement corrugated or semi corrugated sheets in roof fixed with L hook or cranked bolt
53S & F Pre- painted galvalume aluminium zinc coating GI based corrugated steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws as specified
54S&F Pre-painted galvalume aluminum zinc coating GI based Plain steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws as specified
55Demolition of cement concrete (un-reinforced) as path, paving and any position and any thickness complete all as specified and directed.
56M & L for 75 mm thick cement concrete 1:3:6 type C2 (using 40mm graded stone aggregate) as in plinth protection laid in bays & surfaces finished even and smooth , complete all as specified.
57M & L for 40 mm thick cement concrete 1:2:4 type B1 (using 12.5mm graded stone aggregate) as in floor & surfaces finished even and fair using extra cement, complete all as specified.
58Demolition of reinforced cement concrete in any position all as specified and as directed by Engineer -in-Charge.
59Material and labour for reinforced cement concrete 1:2:4 type B1 (using 20mm graded stone aggregate) as in roof slabs, slab supported on walls, cooking platform, beams and columns, in floors roofs, landings, balconies, canopies and in chajjas, parapet, shelves and the like complete all as specified and directed.
60Use and waste of form work to soffits of suspended slabs such as roof slab, Chajja, platforms and landings etc not exc 200mm thick (horizontal or sloping) for fair finished surfaces of concrete complete all as specified and directed.
61S&F TMT steel bars of 10 mm dia and over, cut to length bent to shape required, including cranking bending spirally for hopping for columns, hooking ends and binding with mild steel wire (annealed) not less than 0.9 mm dia or securing with clips quality conforming to. complete all as specified and as directed.
62S&F 20 mm bore tank nipple suitable for HDPE water tank. (Minimum weight 15 mm-38gms/20mm- 45gms /25mm- 65gms) complete all as specified and directed
63S&F 25 mm bore tank nipple suitable for HDPE water tank. (Minimum weight 15 mm-38gms/20mm- 45gms /25mm- 65gms) complete all as specified and directed
64Demolition and breaking up rain water pipes (CI,AC,PVC etc) set in any cement mortar of any diameter incl bends.
65S/F PVC (SWR) pipes, single socketed, in any length with rubber ring joints, laid in trenches or in floors, soil, waste, vent pipe in any length with or without ears ,110mm bore complete.
66S/F PVC (SWR) pipes, single socketed, in any length with rubber ring joints, laid in trenches or in floors, soil, waste, vent pipe in any length with or without ears 75 mm bore complete.
67Supply only for broken brick coarse aggregate n.exc 40mm deposited, spread and levelled in layers watered and rammed to a true surfaces complete all as specified.
68Dismantling wrought iron or mild steel work of any description not otherwise provided for roof trusses and purlins complete all as specified and as directed.
69S&F rolled sections as in main and cross beams, hip and jack rafters; purlins , pillars, trusses , water tank stage , framed guard bars, barred iron doors, ladders, frame balusters, walk ways, railing and similar work where connected to common rafters and running rails and guides for sliding doors; fixed with angle cleats or other connecting plates complete all as specified and directed
70Demolition Mud in roofs, any thickness, including plastering and lapping (whether full thickness removed or only a part thereof) all as specified and directed.
71M&L for cement concrete 1:2:4 type B1 (using 12.5mm graded stone aggregate) on roof padding surface finished even and smooth without using extra cement complete all as spd & directed.
72M&L for rendering 10mm thick on top of roof concrete in cement mortar 1:4 with water proofing compound at the rate of 3% by weight of cement to have a smooth surface for laying of water proofing membrane. Note: Water proofing compound will be measured and paid seprately.
73M&L for APP based polymeric membrane plain finish minimum weighting 3 kg/Sqm and minimum 3mm thick reinforced with polyster non woven fabric (wt not less than 150 gms/sqm) over one coat of 85/25 bitumen @1.2 kg/sqm and paste the membrane with torching method and again apply a coat of 85/25 bitumen @ 1.2 kg/sqm at overlapping joints
74S & F for Heat Resistant Terrace Tiles (300 mm x 300 mm x 20 mm) with SRI (solar refractive index) > 78, solar reflection > 0.70 and initial emittance > 0.75 on waterproof and sloped surface of terrace, laid on 20 mm thick cement sand mortar in the ratio of 1:4 (1 cement : 4 coarse sand) and grouting the joints with mix of white cement & marble powder in ratio of 1:1, including rubbing and polishing of the surface up to 3 cuts complete, including providing skirting up to 150 mm height along the parapet walls in the same manner incl 15 mm thick screed bed in 1:6.
75Supply and fix shower rose, chromium plated brass, fancy type, 125x125 mm, with or without swivel , any size, including fixing to steel pipe or union, complete all as directed.
76S&F in repairs Vitreous china wash down water closet pan (pedestal pattern), white, including flush pipe of polyethylene of low or high density or PVC 32 mm dia., plastic water closet seat closed pattern with cover and hinging device and trap with connection complete all as specified.
77Supply and fix PVC low level white flushing cistern valveless syphonic action type 10 lts capacity with inlet, ball valve, float and handle including PVC flush pipe 32 mm dia with bend and a pair of mild steel angle iron brackets of suitable size including making necessary connections to water supply pipe line and WC, complete all as specified.
78Supply and fix vitreous china squatting pan Orissa pattern long pan size 580x440mm white with integral foot rests ‘P’ or ‘S’ trap front or back inlet (excluding flushing cistern and flush pipe ) complete all as specified and directed by Engr-in-Charge.
79S&F Vitreous china urinal partition white of size 310x700 mm with Urinal spreader of PTMT any colour for fixing with 15 mm dia pipe. (Minimum weight 60gms including all fitting
80S&F Vitreous China bowl urinal flat back, size of 465 x 355 x 265 mm white (minimum), with grating and union for discharge pipe (excluding flushing cistern, flush pipe and waste pipe)Vitreous China urinals, bowl type (back or corner wall type),complete including providing and fixing plugs, bedding urinal against wall in cement mortar 1:2, securing urinal to plugs with and including 60mm long brass screws, pointing around urinal back in cement; fixing automatic flushing cistern with brackets,flush pipe, grating and Union for discharge pipe. (Exclusive of fixing supply pipe to flushing cistern, trap and waste pipe)
81Supply and fixing factory made uPVC door frame made of uPVC. extruded sections having an overall dimension (extruded section profile) 48x40 mm (tolerance ± 1 mm), with wall thickness 2.0 mm (± 0.2 mm), corners of the door frame Jointed withgalvanized brackets and stainless steel screws, joints mitred and Plastic welded. The hinge side vertical of the frames reinforced by galvanized M.S. tube of size 19 X 19 mm and 1mm (± 0.1 mm) wall thickness and 3 nos. stainless steel hinges fixed to the frame complete all as specified by the manufacturer and as per directions of Engineer-in-charge
82Supply, and fixing 30 mm thick factory made Polyvinyl Chloride (PVC) door shutter made of styles and rails of a uPVC hollow section of size 60x30 mm and wall thickness 2 mm (± 0.2 mm), with inbuilt decorative moulding edging on one side. The styles and rails mitred and jointed at the corners by means of M.S. galvanised/ plastic brackets of size 75x220 mm having wall thickness 1.0 mm and stainless steel screws. The styles of the shutter reinforced by inserting galvanised M.S. tube of size 25x20 mm and 1 mm (± 0.1 mm) wall thickenss. The lock rail made up of 'H' section, a uPVC hollow section of size 100x30 mm and 2 mm ( + 0.2 mm) wall thickness fixed to the shutter styles by means of plastic/ galvanised M.S. 'U' cleats. The shutter frame filled with a uPVC multichambered single panel of size not less than 620 mm, having over all thickness of 20 mm and 1 mm (± 0.1 mm) wall thickness. The panels filled vertically and tie bar at two places by insering horizontally 6 mm galvanised M.S. rod and fastened with nuts and washers, complete as specified by the manufacturer and as per directions of Engineerin- charge.
83Taking down carefully copper/aluminium point wiring from wooden battan or conduits (light, fan, socket or power) complete including (fittings such as switches, ceiling roses, pendants, regulator, sockets etc. to be measured separately) and making good disturbed surfaces of walls, floor etc to match the existing surface.
84Taking down old MCCB , TPN DBs , SPN DBs, & main switch/ enclosure box of any make and type from the site and making good surface complete all as specified and directed.
85Taking down old submain wiring of any size, including coduit and make from the site complete all as specified.
86Taking down old unsv light fitting of any size and make from the site and making good surface complete all as specified.
87M & L for Point wiring complete with 1.5 sqmm single core PVC insulated FRLSH cable unsheathed 1100 volts grade with multi stranded copper conductor drawn through and including non-metalic rigid new PVC conduit medium grade ISI Marked not less than 20 mm dia and all conduit accessories concealed in wall on surface in ceiling/fixed to roof/truss/columns etc and including provision of 1.5 sqmm PVC insulated copper cable FRLSH unsheathed as earth continuty, fabricated modular metal flush box, concealed in walls with suitable modular inner and outer plate for housing switches , socket out let and fan regulators etc, complete all as specified.
88All as per item No 87 here -in-before but one light/ fan point controlled by one switch.
89All as per item No 87 here -in-before but one 3 pin 5 Amps socket outlet point controlled by one No one way switch on independent board but not below the switch board of light points in same vertical plate..
90All as per item No 87 here -in-before but one 3 pin 5 Amps socket outlet point controlled by one No one way switch on same board
91M&L point wiring with PVC unsheathed multi stranded copper conductor cable 4.0 sqmm FRLSH 1100 Volts in New PVC concealed conduit medium grade ISI Marked not less than 20 mm dia in new M S steel terminal boxes modular including one run of using 4.0 sqmm FRLSH 1100 Volts copper conductor cable as earth continuity connected to common earth for one 15 A switch socket power point, all as specified
92M&L switch Modular type 6 Amps one way ISI marked 230V AC complete all as specified Make : Legrand Cat Part No 573400 / Schnider Cat No X1001WH / Wipro Cat No RF 110
93M&L Modular socket outlet 5 pin 6 Amp socket 2 module ISI marked complete all as specified Make : Legrand Cat Part No 573424/ /Schnider Cat No X2005WHNS/ Wipro Cat No R 1212
94M&L switch Modular type 16 Amps one way ISI marked 230V AC complete all as specified Make : Legrand Cat Part No 573410/ Schnider Cat No X11001WH/ Wipro Cat No RF 130
95M&L Modular socket outlet 5 pin 6/16 Amp universal socket 2 module complete all as specified Make : Legrand Cat Part No 573471/ Schnider Cat No X2106WH/Wipro Cat No R 1332P
96M&L ceiling rose 3 phase PVC polycorbonate,isolated body. complete all as specified.
97M&L for submain wiring with two single core PVC insulated FRLSH 1100 Volts unseathed stranded copper conductor cable 6 Sqmm in and including new PVC conduit medium grade not less than 20 mm dia, for submain wiring and connection complete FRLSH 1100 volts unsheathed stranded copper conuctor cable of 6Sqmm size stranded conductor as earthwire.Note:- Two run of main wire PVC insulated FRLSH 1100 volts unsheathed stranded copper conductor and one run of earth wire with one run of PVC conduit will be measured and paid in one length.
98M&L for submain wiring with two single core PVC insulated FRLSH 1100 Volts unseathed stranded copper conductor cable 4 Sqmm in and including new PVC conduit medium grade not less than 20 mm dia, for submain wiring and connection complete FRLSH 1100 volts unsheathed stranded copper conuctor cable of 4.0 Sqmm size stranded conductor as earthwire.Note:- Two run of main wire PVC insulated FRLSH 1100 volts unsheathed stranded copper conductor and one run of earth wire with one run of PVC conduit will be measured and paid in one length.
99M & L for earthing complete with galvanized steel earth plate 600x600x6mm thick buried vertically in ground to depth not less than 2.25 mtr below ground level, with top edge of the plate not less than 1.50 mtr below normal ground level, connected to earth lead GI 4mm dia by means of bolts, nuts, check nuts and washers of galvanized iron and connection to main switch board of panel, including watering pipe GI 20 mm bore light grade 15mm bore for earthing lead, wire mess, funnel, salt, charcoal dust, excavation and refilling pit with PCC 1:2:4 type B1(using 20mm dia stone aggregate) reinforced with 6mm dia round bar @ 75mm cement concrete both always with MS handle 12mm dai and frame all as shown in electric plate No 3 in page 497 of SSR Part I (2009) including testing ion completion all as directed
100Supply & fix in repair factory made epoxy powder coated Distribution Board VTPN-4 ways (IP-30 protection), mechanical impact strength IK - 07, with cement spill protector double door fabricated from minimum 1.6mm thick CRCA sheet and fixed flush to wall and suitable for universal mounting and including 200 Amp copper bus bar, neutral bar, standard DIN rail, Earth bar and cable ties for cable management, top and bottom removeable gland plates with knockouts and suitable for one MCCB 100 to 160 Amp as incomer and 40 to 63 Amp SP MCBs outgoing complete all as specified Note :- MCCB & MCB will be measured & paid separately.
101M&L in replacement MCCB 100 Amps, 415 volts, 16 KA , 4P, optium 2.0 adjustable thermal setting Ics=100% Icu as per IEC 60947-II suitable for isolation , fixed over load and fixed short sircuit setting complete all as soecified & as directed
102Supply and fix MCB DB SPN 12 way Horizontal, IP - 30 Protection double door 240 V AC 50Hz with for MCB SPN as incomer and SP MCBs as out going with tinned copper bus bar ,neutral link earth link complet.
103M&L MCB SPN 40 Amp \\"C \\" curve all as directed.
104M&L MCB SP 6 to 32 Amp \\"C\\" curve all as directed.
105Supply and fix LED batten luminaire surface mounted, 4 feet system wattage of 20 Watts, including connecting up with PVC sheathed 1.5 sqmm 3 core copper conductor flexible wire from ceiling rose to fitting fixed complete all as specified and directed.
106Supply and fix LED batten luminaire surface mounted, 2 feet system wattage of 10 Watts, including connecting up with PVC sheathed 1.5 sqmm 3 core copper conductor flexible wire from ceiling rose to fitting fixed complete all as specified and directed.
107S & F in replacement pressure die cast aluminium housing LED street light luminaires with IP-66 deg. of protection suitable for 35/40 watt LED fitting, Power Factor > 0.90 voltage range - 150 to 270 Volts AC, temperature range 0 to 50 Degree C, system efficency at luminaire level > 100 duly fixed on suitable size of GI pipe light grade including 32 X 5 mm thick MS flat with suitable size of fastner including making connection flexible copper conductor cable from ceiling rose to fitting complete all as specified and directed. Note : The Contractor quoated the rates incl all accessories like suitable GI pipe, 40x6 mm thick MS flat, fashner, nut & bolts, suitable length of flexiable wire.
108Supply and fix 10 watts bulkhead fitting with powder coated die cast aluminium housing with glass/ non yellowing polycarbonate cover, IP-65 Protection, System level efficacy of the Luminary is > 90 lumen/watts at L70 criteria, Power Factor > 0.90, driver with Voltage range 150-270V, Temperature range 0 to 50 Deg, Driver efficiency >85%, THD<10%, CRI>80, Color Temperature-5700K, Surge protection of 2.5 KV, including connecting up with necessary PVC sheathed 3 core 1.5 Sqmm copper conductor flexible wire fixed complete.
109Taking down carefully the existing ceiling fan of 1200mm from its position after disconnecting electric connection and deposits in MES Store all as specified and directed.
110Supply and fixing ceiling fans three blade, Robust and reliable inverter motor (brush less DC Motor) powered by BLDC technology, BEE 5 star rating for energy saving, down rod, electonic regulators, fan canopy, remote of ceiling fan & accessories, rated Air delivery >220 cum/min, service valve > 6, AC single phase 230/240 V of size 1200 mm sweep including making connection with three core flexible, copper cable pvc insulated of suitable length, complete all as directed.
111S&f fresh air fan PVC body, air delivery > 800 CMH , 5 number of blades, AC single phase 230/240 V of size 250 mm sweep with louvre fixed complete with suitable size ply by cutting into suitable size as required complete.
112Taking down old unsv fresh air fan of any size & any capacity & deposit to MES store yard all as specified and directed.
113S & F water heater storage type Geyser vertical type with suitable size of fastner and, inner tank material of superior glass line tank and outer body material of ABS with high pressure with standing enabling (up to 8 bar pressure) capacity including provision and connecting up of SS braided pipe og sizr 15 x 60 mm long with brass adopter for inlet and outlet water connection having adjustable knob for temperature control , digitial display for showing the temperature of geysers and inner tank should be glass line coated, capacity 25 Ltrs, having heating element 2.0 KW with ISI marked suitable for hot and cold water and not less than 5 star rating, suitable for ,230 volt, 50 Hz electric supply complete all as specified and directed.
114Taking down carefully the existing Old U/S Geyser capacity 25 Ltr its position after disconnecting electric & water connection and deposits in MES Store all as specified and directed.
115Supply only in repairs recessed mounting LED FLAT panel 2\\"x2\\" made of CRCA sheet steel duly power coated with high efficient LED and glaire free full opal diffuser , IP 20 Suitable for 36 watt, 230 volts ,50 Hz AC Supply, Neutral White,with electronic driver and incluiding all fixing accessories complete all as specified and directed.
116S&F Modular box with MCB 20 Amp complete with metal box and 3 Pin Top Plug complete all as specified and directed. Make : Indo Asian/Legrand/ Schnider Note : Rates are inclusive of cutting / chases for mounting Modular metal box concealed in wall and making good to the disturbed surfaces with OBD / colour wash / white wash and wall putty where ever required.
117M&L for breaking the old existing wall/glass/wood and making provn of a round hole for fixing of 250 mm sweep fresh air Fan including making good to the disturbed wall/ portion and matching with existing colour.all as specified and directed.
118Schedule of Credit Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 56689965
AUTHORITY Statutory Bodies & Commissions/Committees
TENDER VALUE 48.54 Lakhs
LAST DATE 17-08-2026
Authority
Authority Name Military Engineer Services
Work Description Tender for special Repair / Replacement Of Bldg No T-29 Of Living (Malta Line), Toilet Block No P-21 And T-4-5 Bd (Kandhar Line) Incl B/R & E/M Wks At 105 Inf Bn (Ta) Raj Rif Under Ge (Central) Delhi Cantt-10
Basic Detail
Tender No GE/TOKEN-56/2026-27
Bidding Type Tender
Location
City New Delhi
State Delhi
Key Dates
Publish Date 27 Jul 2026
Submission Date 17 Aug 2026
Open Date 19 Aug 2026
Finance
Tender Value 48.54 Lakhs
Tender Fee 500
EMD 97080
Exemption Available
Document List
BOQ_875043.xls
Tendernotice_1.pdf
tenderpage.pdf
44f57b8d-8ccb-4a85-bfbf-2de322c6dd22.html

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Jul 27, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Aug 17, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 2 days
Aug 19, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 4 days

Tender Documents

Download All (ZIP) ↓
xls

BOQ_875043.xls

pdf

Tendernotice_1.pdf

pdf

tenderpage.pdf

html