Defence Statutory Bodies & Commissions/Committees Closing in 16 days TDR #56689963

Tender For Repair/Maint Of Internal Wiring, Fans And Allied Works At Mouza Dalan Area Under Age (I) Katihar Mil Stn Katihar.

Issued by Statutory Bodies & Commissions/Committees · Katihar, Bihar
Tender Value
8 Lakhs
Estimated cost
Bid Submission
17 Aug 2026
16 days left
EMD
16000
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Katihar → Bihar
EMD Exemption
Available
Quantity
Not Available

Project Description

Tender for Repair/Maint Of Internal Wiring, Fans And Allied Works At Mouza Dalan Area Under Age (I) Katihar Mil Stn Katihar.

BOQ

Name of Work:- REPAIR/MAINT OF INTERNAL WIRING, FANS AND ALLIED WORKS AT MOUZA DALAN AREA UNDER AGE (I) KATIHAR MIL STN KATIHAR.
Sl. No. Item Description
1Material and labour for point wiring for one light/fan/call bell point with 1.5 sqmm PVC insulated (FR-LSH) unsheathed copper multistranded conductor cable 1100 volts grade controlled by one way switch including 1.5 sqmm PVC insulated (FR-LSH) unsheathed copper multistrand conductor cable 1100 volts grade for continuity earth wire connected to common earth dolly drawn through and including PVC casing caping with all accessories and sunk cast pressed steel terminal box made out of MS sheet 1.25mm thick with 3mm thick hylum laminated/bakalite sheet cover for mounting switch, socket, fan regulator,etc after and including taking down of old existing point wiring including fixtures and fittings such as switch, ceiling rose, holders, socket, etc and making good the distrubed surfaces as per the existing complete all as specified and as directed by the Engr-in-Charge. Note: Red coloured cable shall be used for live connection, black coloured cable shall be used for neutral connection and green coloured cable shall be used for earthing. Separate cable for earthing and neutral to be used for each individual circuit from the distribution board.
2All as per item No 1 here-in-before but for 3 pin 6 Amps socket out let on the same board with 1.5 sqmm cable complete all as specified and as directed by the Engr-in-Charge.
3All as per item No 1 here-in-before but for 5 pin 6 Amps switch socket combination on the independent board with 1.5 sqmm cable complete all as specified and as directed by the Engr-in-Charge.
4All as per item No 1 here-in-before but for one 5 pin 6/16 Amps switch socket combination on independent board with 2.5 Sqmm PVC insulated unsheathed copper cable multistrand conductor 1100 volts grade and 2.5 sqmm copper conductor cable as earth continuity conductor complete all as specified and as directed by the Engr-in-Charge.
5S&F in repair Switch piano, flush type single pole, one way 6 Amp complete all as specified and as directed by the Engr-in-Charge.
6S&F in repair Socket outlet,3 pin 6 amp flush type complete all as specified and as directed by the Engr-in-Charge.
7Supply and fix in repair Switch socket combination 2in 1, 6 Amp flush type universal complete all as specified and as directed by the Engr-in-Charge.
8Supply and fix Switch socket combination 2in 1, 3 pin, 6 and 16 Amp flush type universal complete all as specified and as directed by the Engr-in-Charge.
9Supply and fix in repair bell ding dong AC 230 volts, single pole complete all as specified and as directed by the Engr-in-Charge.
10Supply and fix in repair Bell push, flush type, 5 amp complete all as specified and as directed by the Engr-in-Charge.
11Supply and fix in repair ceiling rose surface bakelite three terminal 65 x 50mm complete all as specified and as directed by the Engr-in-Charge.
12S&F in repair batton/ Angle holder insulated body with back plate suitable to batton fiting complete all as specified and as directed by the Engr-in-Charge.
13Supply and fix in repair stepped type electronic fan regulator flush type on the existing phenolic laminated sheet etc. as reqd complete all as specified and directed by the Engr in-Charge.
14S & F in repair single pole and neutral enclosure with two pin and earth, plug and socket, suitable for single phase 240 V, complete with one single pole MCB of capacity 20 amps having `C` charactristic, breaking capacity 10 KA, including industial plug top, including taking down old u/s one complete all as specified and as directed by the Engr-in-Charge.
15Supply and fix in repair PVC rectangular block of Size 10cm x 10cm x 5cm with 3mm thick industrial plastic laminated sheet duly cut for fixing switch,socket, fan regulator etc of the following size complete all as specified and as directed by the Engr-in-Charge.
16Supply and fix in repair PVC rectangular block of Size 25cm x 20 cm x 5 cm with 3mm thick industrial plastic laminated sheet duly cut for fixing switch,socket, fan regulator etc of the following size complete all as specified and as directed by the Engr-in-Charge.
17Supply and fixing in repair LED light fittings 1x20 W ,220V, AC decorative box type with driver, holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete all as specified and as directed by the Engr-in-Charge.
18Supply and fixing in repair LED light fitting mirror type with high out put diffuser 2 feet, 10 watt 220 V AC decorative type with driver holder and LED lamp including connecting up with three core flexible copper conductor cable of suitable size complete all as specified and as directed by the Engr-in-Charge.
19Supply and fixing in repair LED luminaire 600 mm x 600 mm, 35/36 watt, 220 V AC recessed type with high efficiency PMMA diffuser soft glare free light complete with driver, holders & LED lamp suitable for roof ceiling including connecting up with driver three core flexible copper conductor cases of suitable size complete all as specified and as directed by the Engr-in-Charge.
20Supply and fixing round shape 6 watt 220 volts AC recessed type with high efficiency PMMA diffuser soft glare free light complete with drivers, holders,LED lamp suitable for roof ceiling including connecting up with three core flexible copper conductor cable of suitable sizecomplete all as specified and as directed by the Engr-in-Charge.
21Supply and fixing as in repair MCB DB TPN 4 ways double door with 200 Amps rated bus bar neutral link, earth bar and din rail, recessed with wall surfaces by chase cutting and making good surfaces of wall complete all as specified and as directed by the Engr-in-Charge.
22Supply and fixing as in repair MCB DB SPN 12 ways double door with 200 Amps rated bus bar neutral link, earth bar and din rail, recessed with wall surfaces by chase cutting and making good surfaces of wall complete all as specified and as directed by the Engr-in-Charge.
23Supply and fixing as in repair MCB DB SPN 8 ways double door with 200 Amps rated bus bar neutral link, earth bar and din rail, recessed with wall surfaces by chase cutting and making good surfaces of wall complete all as specified and as directed by the Engr-in-Charge.
24Supply and fixing as in repair MCB DB SPN 4 ways double door, recessed with wall surfaces by chase cutting and making good surfaces of wall complete all as specified and as directed by the Engr-in-Charge.
25Supply and fixing in repair MCB 40 - 63 Amps, TPN, 240 Volt \\"C\\" series, breaking capacity 10 KA complete all as specified and as directed by the Engr-in-Charge.
26Supply and fixing in repair MCB 40 - 63 Amps, SPN, 240 Volt \\"C\\" series, breaking capacity 10 KA complete all as specified and as directed by the Engr-in-Charge.
27Supply and fixing in repair MCB 06 - 32 Amps, SPN, 240 Volt \\"C\\" series, breaking capacity 10 KA complete all as specified and as directed by the Engr-in-Charge.
28Supply and fixing as in repair MCB 6 to 32 Amps, single pole, 240 Volt \\"C\\" series, breaking capacity 10 KA complete all as specified and as directed by the Engr-in-Charge.
29Supply and fix sub-main wiring for main DB's to Sub DB's with PVC insulated & unsheathed two run of 4 Sqmm single core multi stranded copper conductor cable (FRLS), 1100 Volt grade alongwith one run of 4 Sqmm PVC insulated & unsheathed copper conductor cable (FRLS), 1100 Volt grade, connected to common earth dolly as earth continuity conductor, drawn through PVC casing caping and including taking down existing one complete all as specified and as directed by the Engr-in-Charge. Note : Three runs of 4 Sqmm cable shall measured as one length.
30Taking down ceiling fan of any type, any make and any sweep from its position for repairing work, opening the body and blade, checking for repalcement of unserviceable spares, cleaning, overhauling & greasing, replacement of unserviceable spare by new one, re-assembling of all the components, testing and hanging it up in its original position, complete all as specified and as directed by the Engr-in-Charge. Note : New spare parts required for replacement shall be measured and paid seperately.
31Supply only MS split pin size 2 \\" x 1/8 \\" for ceiling fan of 1200/1400mm Sweep complete all as specified and as directed by the Engr-in-Charge.
32Supply only Hanging bolt with nut of size 3/8\\" x 3 1/2 \\" for ceiling fan of 1200/1400mm Sweep complete all as specified and as directed by the Engr-in-Charge. Make : TATA or equivalent approved make.
33Supply only Rubber bush of size 1 1/2 \\" dia x 1\\" thick for ceiling fan of 1200/1400mm Sweep complete all as specified and as directed by the Engr-in-Charge.
34Supply only Ball bearing of size 6201/6202/6203 for ceiling fan of 1200/1400mm Sweep complete all as specified and as directed by the Engr-in-Charge. Make : TATA/SKF
35Supply only Gun Metal bushing for ceiling fan of 1200/1400mm Sweep complete all as specified and as directed by the Engr-in-Charge. Make : TATA/SKF
36Supply only ceiling fan spindle before complete all as specified and as directed by Engr-in-charge.
37S&F for standard blade fixing with screws suitable to ceiling fan 1200mm Sweep, after taking down old existing unserviceable, complete all as specified and as directed by the Engr-in-Charge.
38S&F for down rod of 1.5' height fabricated out of MS pipe 12 mm dia heavy duty painted with brown paint suitable to ceiling fan of any description make brand and model after taking down old existing unserviceable down rod complete all as specified and as directed by the Engr-in-Charge.
39S&F hanging hook \\"S\\" type suitable for ceiling fan of any capacity including taking down old unserviceable ones, complete all as specified and as directed by the Engr-in-Charge.
40Supply and fixing as in repair 2.5 mfd capacitor complete all as specified and as directed by the Engr-in-Charge.
41Supply and fixing as in repair 3.5 mfd capacitor complete all as specified and as directed by the Engr-in-Charge.
42Taking down exhaust fan of any type, any make and any sweep from its position for repairing work, opening the body and blade, checking for repalcement of unserviceable spares, cleaning, overhauling & greasing, replacement of unserviceable spare by new one, re-assembling of all the components, testing and hanging it up in its original position,including plywork, complete all as specified and as directed by the Engr-in-Charge. Note : New spare parts required for replacement shall be measured and paid seperately.
43Supply only Ball bearing 2001/ 2002/ 2003 for exhaust fans complete all as specified and as directed by the Engr-in-Charge. Make : TATA/SKF
44Supply only Metal bush bearing for exhaust fans complete all as specified and as directed by the Engr-in-Charge. Make : TATA/SKF
45S&F for standard blade fixing with screws suitable to Exhaust Fan Blade including taking down old unserviceable ones, complete all as specified and as directed by the Engr-in-Charge.
46Supply and fixing as in repair M.S. galvanised louvers suitable for exhust fan of size 300mm to 450mm sweepcomplete all as specified and as directed by the Engr-in-Charge.
47Material and labour for painting of ceiling fan of size 1200mm/ 1400mm sweep with down rod by spray painting with two coats of synthetic enamel paint after preparation old painted surface by scraping/ removing old paint by emery paper including writing of MES No complete all as specified and as directed by the Engr-in-Charge.
48Material and labour for painting of exhaust fan of size 300mm to 450mm sweep by spray painting with two coats of synthetic enamel paint after preparation old painted surface by scraping/ removing old paint by emery paper including writing of MES Nocomplete all as specified and as directed by the Engr-in-Charge.
49M&L as in repair for wire flexible PVC insulated copper conductor twin core twisted of size 23/0.00076 including taking down old unserviceable ones, complete all as specified and as directed by the Engr-in-Charge. Please Enable Macros to View BoQ information
50M&L as in repair for wire flexible PVC insulated copper conductor twin core twisted of size 23/0.00076 including taking down old unserviceable ones, complete all as specified and as directed by the Engr-in-Charge. Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 56689963
AUTHORITY Statutory Bodies & Commissions/Committees
TENDER VALUE 8 Lakhs
LAST DATE 17-08-2026
Authority
Authority Name Military Engineer Services
Work Description Tender for Repair/Maint Of Internal Wiring, Fans And Allied Works At Mouza Dalan Area Under Age (I) Katihar Mil Stn Katihar.
Basic Detail
Tender No C/8082/E8
Bidding Type Tender
Location
City Katihar
State Bihar
Key Dates
Publish Date 27 Jul 2026
Submission Date 17 Aug 2026
Open Date 24 Aug 2026
Finance
Tender Value 8 Lakhs
Tender Fee 500
EMD 16000
Exemption Available
Document List
2f5f9fb6-835c-40a2-8a6a-63dea9015aa6.html
BOQ_874898.xls
tender8082.pdf
Tendernotice_1.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Jul 27, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Aug 17, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 16 days
Aug 24, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 23 days

Tender Documents

Download All (ZIP) ↓
html

2f5f9fb6-835c-40a2-8a6a-63dea9015aa6.html

xls

BOQ_874898.xls

pdf

tender8082.pdf

pdf

Tendernotice_1.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender