Tender For Special Repair To Old Aluminium Wiring Into Concealed Copper Wiring With Conventional Luminaries Into Led Light At Hospital Complex P-6/6 Family Ward, P-8/6 Icu &Offrs Ward And P-9/6A Qm Office & Medical Store At 161 Mh At Stn Pithoragarh
Tender Overview
Project Description
Tender for Special Repair To Old Aluminium Wiring Into Concealed Copper Wiring With Conventional Luminaries Into Led Light At Hospital Complex P-6/6 Family Ward, P-8/6 Icu &Offrs Ward And P-9/6A Qm Office & Medical Store At 161 Mh At Stn Pithoragarh Under Ge(Mes) Pithoragarh
BOQ
| Sl. No. | Item Description |
| 1 | DESCRIPTION OF ITEMS |
| 2 | Taking down carefully copper/aluminium point wiring (light, fan, socket or power) complete, including fixture and fittings such as switches, ceiling roses, pendants, regulators, sockets, light fitting, bell, bell push etc and removing material for taking credit (credit for material should be made as per condition separately). |
| 3 | Point wiring of one light point/fan/bell point controlled by one switch with 1.5 sqmm PVC insulated unsheathed copper conductor single core multi strand flexible cable FRLS with proper color coding and 1.5 sqmm PVC insulated unsheathed copper conductor single core multistranded cable (green color) as earth lead in and including concealed non metalic rigid PVC conduit medium grade size 20 mm dia or higher with all fittings (ISI Marked) controlled by one switch including CI/MS sunk box for Piano type wiring or metal flush box for modular wiring of required size & as directed & 3 mm thick plastic laminated sheet for piano type wiring or cover plate for with frame modular type, including cutting chases to wall and making good the disturbed surfaces to match with the existing specification complete all as specified. |
| 4 | All as per srl item No-2 here in before but with 2.5 Sqmm PVC insulated unsheathed copper conductor including earth wire controlled by one 3 pin 15 Amps socket outlet on independent board and ditto. |
| 5 | All as per srl item No-2 here in above but with 2.5 Sqmm PVC insulated unsheathed copper conductor including earth wire controlled by one 3 pin 15 Amps socket outlet on same board and idtto. |
| 6 | All as per srl item No-2 here in above but Point wiring one 3 pin 15 Amps socket outlet independent with 4 sqmm |
| 7 | All as per srl item No-2 here in above but for one 3 pin 5A socket outlet on independent board |
| 8 | All as per srl item No-2 here in above but for one 5A socket outlet on the same board . |
| 9 | S&F in repair for submain wiring with two single core PVC insulated flexible copper conductor multistranded cable (FRLS) of size 4 Sqmm with proper color coding and one single core PVC insulated flexible copper conductor multistranded cable green colour of size 4 Sqmm as earth lead in & including concealed PVC conduit medium grade 20mm dia cutting chases to walls for laying conduit and making good the disturbed wall surfaces to match with existing specification all as required at site or directed. |
| 10 | S&F in repair for submain wiring with two single core PVC insulated flexible copper conductor multistranded cable (FRLS) of size 6 Sqmm with proper color coding and one single core PVC insulated flexible copper conductor multistranded cable green colour of size 6 Sqmm as earth lead in & including concealed PVC conduit medium grade 25mm dia cutting chases to walls for laying conduit and making good the disturbed wall surfaces to match with existing specification all as required at site or directed. |
| 11 | S&F in repair for submain 3 phase wiring with four single core PVC insulated flexible copper conductor multistranded cable (FRLS) of size 10 Sqmm with proper color coding and one single core PVC insulated flexible copper conductor multistranded cable green colour of size 10 Sqmm as earth lead in & including concealed PVC conduit medium grade 32 mm dia cutting chases to walls for laying conduit and making good the disturbed wall surfaces to match with existing surface , all as specified and directed by Engr-in-Charge. |
| 12 | S&F in repair for submain 3 phase wiring with four single core PVC insulated flexible copper conductor multistranded cable (FRLS) of size 16 Sqmm with proper color coding and one single core PVC insulated flexible copper conductor multistranded cable green colour of size 16 Sqmm as earth lead in & including concealed PVC conduit medium grade 32 mm dia cutting chases to walls for laying conduit and making good the disturbed wall surfaces to match with existing specification all as required at site or directed. |
| 13 | S&F of ceiling rose surface bakelite 3 terminals. |
| 14 | S&F of switch modular type single pole one way 1 module 6 amps 240 volts. Sample approved by GE or as per exsisting at site, all as specified and directed by Engr-in- Charge. |
| 15 | S&F of switch modular type one way 1 module 16 amps 230 Volts. Sample approved by GE , all as specified and directed by Engr-in- Charge. |
| 16 | S&F of socket 6 amps modular type 2/3 pin combined 2 module , 230 volts.Sample approved by GE , all as specified and directed by Engr-in- Charge. |
| 17 | S&F of socket modular type , 2/3 pin, 6 and 16 amps combined 2 module, 230 volts. Sample approved by GE , all as specified and directed by Engr-in- Charge. |
| 18 | S&F of Modular type Electronic fan regulator stepped type,two module with five step 240 volts,100Watt suitable for 1200/1400 mm sweep AC ceiling fan complete, Sample approved by GE , all as specified and directed by Engr-in- Charge. |
| 19 | S&F of bell push AC SP 240 volts Modular type 5/6 Amps, single pole one way complete as all specified and directed. Sample approved by GE , all as specified and directed by Engr-in- Charge. |
| 20 | S&F of bell electric multi music type / AC SP 240 Volts Complete all as specified and directed. |
| 21 | S&F of Tube light fitting integrated type suitable for LED 20 W(4 feet) efficacy min 100 lumens/watt, indoor decorative LED batten complete with Aluminium housing and all accessories pre wired and making connection with cord flexible copper cable of suitable size from ceiling rose to PVC connection to light fitting complete all as specified and directed. |
| 22 | S&F of Tube light fitting integrated type suitable for LED 10 W (2 feet) efficacy min 100 lumens/watt, indoor decorative LED batten complete with Aluminium housing with all accessories pre wired and making connection with cord flexible copper cable of suitable size from ceiling rose to PVC connection to light fitting complete all as specified and directed. |
| 23 | S&F of LED bulk head fitting with opal diffuser min 10 Watt, 6500 K, IP-65, with Aluminium housing of efficient heat dissipation and integrated electronic driver with surge protection complete connecting electrically all as directed. |
| 24 | S&F of LED light fitting recess mounted min 32/36 Watt, 6500 K 2' x 2' with surge protection and high voltage protection up to 380 VAC and all accessories suitable for amstrong/grid/POP ceiling complete with integrated electronic driver and making electrical connection properly all as directed. |
| 25 | S&F of Tube light fitting integrated type suitable for LED 20 W(4 feet) PIR occupancy sensor based, to reduce power consumption efficacy min 100 lumens/watt, indoor decorative LED batten complete with Aluminium housing with surge protection and high voltage protection and all accessories pre wired and making connection with cord flexible copper cable of suitable size from ceiling rose to PVC connection to light fitting complete all as specified and directed. |
| 26 | S&F in repair of modular type 3/4 module power unit with 16 Amp plugtop Box with sheet steel enclosure MCB Combo plug and socket complete with one SP MCB 20 Amps, 240 Volts. Protection to human shock due to direct or indirect contact as well as provides protection from overload and short circuit faults, all as specifed and direced. |
| 27 | S&F in repair of TPN DB, 4 Way, as per IS-8523, IP-42 protection, universal mounting with 200A copper bus bar with neutral bar, earth bar and cable ties for cable management, top and bottom removable gland plate suitable for MCB TPN as incomer and MCB TPN/MCB as outgoing, with and including provision for MCCB/MCBs & making necessary electrical connection for Incoming & outgoing cables, with copper lugs, crimped with crimping tool |
| 28 | S&F in repair of MCB FP TPN of 63-100 Amp, voltage rating 415 V,10 KA C- curve with connection testing and commisioning. |
| 29 | S & F in repair distribution board iron clad, double door with IP-43 1K-09 protection suitable for MCCB as incommer and MCB as outgoing 415 Volts 3 phase 50 Hz, VTPN DB 4 way, complete with appropriate size copper bus bar 160 A and neutral link, complete with one MCCB 4 pole 415 Volts 125 Amps rating with rupturing cap 25 KA of the same make as of distribution board & with MCBs of required size making connection with thimbles & including cutting chases to wall for fixing DB and making good the disturbed wall surface all as required at site or directed. |
| 30 | S & F in repair distribution board iron clad, double door with IP-43 1K-09 protection suitable for MCCB as incommer and MCB TP as outgoing 415 Volts 3 phase 50 Hz, VTPN DB 8 way, complete with appropriate size copper bus bar 250 A and neutral link, complete with one MCCB 4 pole 415 Volts 160 Amps rating with rupturing cap 25 KA of the same make as of distribution board & with MCBs of required size making connection with thimbles & including cutting chases to wall for fixing DB and making good the disturbed wall surface all as required at site or directed. |
| 31 | S&F in repair of sheet metal enclosure MCB distribution board, double door with IP-43 IK-09 protection with metal door single phase 240 volts 4 way, including suitable size copper bus bar and neutral link fixed flush in wall including chases wall for fixing DB and making good distributed wall surfaces to match with existing specification . |
| 32 | S&F in repair of sheet metal enclosure MCB distribution board, double door with IP-43 IK-09 protection with metal door single phase 240 volts 12 way, including suitable size copper bus bar and neutral link fixed flush in wall including chases wall for fixing DB and making good distributed wall surfaces to match with existing specification . |
| 33 | S&F in repair of MCB SP of 6 to 32 Amp rating 240,10 KA C- curve with connection testing and commisioning. |
| 34 | S&F in repair of MCB DP SPN of 40-63 Amp rating 240,10 KA C- curve with connection testing and commisioning. |
| 35 | Taking down Ceiling/Exhaust Fan any Sweep any type ,from the exsisting site and keep safe and under custody and complete cleaning, Oiling ,Greasing , repair to make fan seveciable with replacement of capacitor / PCB , bearing and nuts washets bolts and clamps of fan and hanging rod of any size/ length and Refixing fan as existing location and connection to celing rose with copper wire twin core complete all as specified and directed. |
| 36 | Taking down LED Light fitting , 2X2 Led Panel, Bulkhead, Bldg secuity light, wall Light, Post top lamp any type, from the exsisting site and keep safe and under custody and complete cleaning, repair to make seveciable by changing driver (if required) of existing make and Refixing the same as existing location and connection to celing rose with copper wire twin core complete all as specified and directed. |
| 37 | Supply and fix Exhaust fan made of sturdy Engineering Plastic , PVC Body of size 250mm sweep single phase 230 V 50 Hz AC 1400 RPM energy saving, heavy duty motor copper wounded with die cast aluminium rotor mounted on two ball bearing complete with louvrs shutter including making hole of suitable size and making good disturbed surface (including making hole and plasterng, nacessary brickwork and distemparing to match with existing surface ) connecting with 2 core copper cable to ceiling rose. All as specified and directed . Note : Old Unsv sfan shall be deposited to MES Store yard. |
| 38 | Supply install and tesing water heater storage type (Geyser) single phase 230 V, 50 Hz, 5 star energy saving high density PUF insulation tank made of heavy duty mangesium anode rod with steel core to protect enamelled tank from rust & corrosion, vertical installation type 25 Ltr Cap 2000 Watt rated power, incoloy 800 glass coated heating element, inner tank coating of feroglas powder, tank made of ultra thick super cold rolled steel plates, rated pressure 0.8 MPa, IPX4 protection consist of safety valves, thermal cut off, thermostat including connecting up and fixing arrangement on wall including providing hole fastners-04 Nos hot and cold water metallic flexible pipes 15 mm bore of adequate length as provided by OEM or required at site - 02 Nos non return valve 01 No and including necessary plumbing work, complete with intergated shock safe plug (PRCD Plug) with all protection features as per OEM design and standard including taking down of old unsv Tank all as specified and directed. Note : Old Unsv Storage tank will be deposited to MES Store yard. |
| 39 | Supply and laying in trenches or fixing to wall/pole or passing through pipe PVC insulated heavy duty XLPE electric cable 95 Sqmm 3.5 Core with aluminium conductor 1100 volts grade heavy duty cable with PVC insulated aluminium multistranded conductor served with an inner sheathing of PVC tape armoured with galvanised steel wire or strip in service connections all as required and directed. |
| 40 | Excavation in trenches in any type of soil n exc 1.5 mtr in width and n. exc 1.5 mtr in depth and getting out all as required for laying of cables,foundation filling of poles or stays and for rerouting of cables. |
| 41 | M&L for sand cushioning to under ground cables 8 cm thick before laying the cable and 15 cm, thick after laying, stretching and testing the cable |
| 42 | M&L for Sub class ‘B’ bricks old size. laid dry flat over the cable abutting each other, length of cable equal to width of brick all as required. |
| 43 | Returning filling, in including spreading ,leveling, watering and well ramming in layers not exc 25 cm each all as required. |
| 44 | Removing excavated material to a distance not exceeding 50 meters and depositing where directed at a level not exc 1.5 mtr above the starting point. |
| 45 | Supply , installing, erecting, commisionning, and testing new factory made MS busbar chamber of nominal dimension of 900mmX600mmX300mm duly provided with ETP grade Copper bus bar 4 way of 50mmX6 mm fixed on porceline insulators out door seather / vermin proof with neoprene rubber gasket along the door opening duly painted powder coated CRCA steel enclosure with . the bus bar chamver to be grouted in wall by Fastner /ground by using angle iron frame of size. cable connection/submain should be with suitable size of chrome plated brass double compression gland provided for incomming and outgoing cables. |
| 46 | M&L for Earthing complete with galvanised cast iron earth plate electrode of size 600x600x6mm thick as earth electrode with top edge of the earth plate not less than 1.5mtr below ground level using GI wire 4mm dia as earth continuity conductor connected to earth plate by means of GI thimbles nuts bolts washers all as directed including providing earth wire protection pipe GI light grade15mm dia from earth plate to main switch board/panel, watering pipe 20mm dia with wire mesh and funnel at top, earth pit and RCC pit cover in PCC 1:3:6 adequate quantity of charcoal dust and salt all around the erth plate, earth work in any type of soil remaing surplus excavated material all as required at site and specified in SSR part I or directed by Engineer-in-charge and testing on completion. Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Tender Published
Tender notice published.
CompletedBid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 18 daysBid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 25 daysTender Documents
Download All (ZIP) ↓We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender