Tender For Provision Of Dg Sets And Electrical Accessories For Data Centre Facility At Cabs Bangalore
Tender Value
4.43 Crore
Estimated cost
Bid Submission
17 Aug 2026
16 days left
EMD
5.18 Lakhs
Bank guarantee accepted
Document Fee
2000
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Bengaluru Urban → Karnataka
EMD Exemption
Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender for Provision Of Dg Sets And Electrical Accessories For Data Centre Facility At Cabs Bangalore
BOQ
| Sl. No. | Item Description |
| 1 | Schedule 'A' Part-I (BUILDINGS AND STRUCTURES)This Schedule (contains under mentioned Sl item No. 1.01) is not prepriced by MES and the prepriced rate indicated in Col - 5 as ₹0.00 indicates this fact only. The tenderer is required to quote their rates in Col 6. |
| 2 | Construction of Operator cum storage room alongwith attached toilet including all fittings and fixtures complete all as specified and as shown on drawings. |
| 3 | Lump sum price worked out by the Contractor for “B/R WORK SERVICES FOR DATA CENTRE FACILITY\\" as listed in Schedule ‘A’ Part - II representing __________ % __________________ percent Above / Below the lump sum price of `16,19,282.95 inserted by the MES in Schedule ‘A’ Part - II |
| 4 | Lump sum price worked out by the Contractor for “B/R PORTION (02 Nos COVER SHEDS) SITE\\" as listed in Schedule ‘A’ Part - III representing __________ % __________________ percent Above / Below the lump sum price of `20,87,349.10 inserted by the MES in Schedule ‘A’ Part - III |
| 5 | Lump sum price worked out by the Contractor for “EXCAVATION AND EARTHWORK\\" as listed in Schedule ‘A’ Part - IV representing __________ % _________________________ percent Above / Below the lump sum price of `42,173.13 inserted by the MES in Schedule ‘A’ Part - IV |
| 6 | Lump sum price worked out by the Contractor for “INTERNAL ELECTRIFICATION” as listed in Schedule ‘A’ Part - V representing __________ % _______________________ percent Above / Below the lump sum price of `10,65,969.00 inserted by the MES in Schedule ‘A’ Part - V |
| 7 | Lump sum price worked out by the Contractor for “INTERNAL WATER SUPPLY” as listed in Schedule ‘A’ Part - VI representing __________ % ____________ percent Above / Below the lump sum price of ₹33,783.45 inserted by the MES in Schedule ‘A’ Part - VI |
| 8 | Lump sum price worked out by the Contractor for “ROAD / PATH / CULVERT / HARDSTANDING” as listed in Schedule ‘A’ Part - VII representing ________ % ____________ percent Above / Below the lump sum price of ₹5,00,073.51 inserted by the MES in Schedule ‘A’ Part - VII |
| 9 | Lump sum price worked out by the Contractor for “SEWAGE DISPOSAL” as listed in Schedule ‘A’ Part - VIII representing _______ % _________________ percent Above / Below the lump sum price of `1,18,847.22 inserted by the MES in Schedule ‘A’ Part - VIII |
| 10 | Lump sum price worked out by the Contractor for “EXTERNAL ELECTRIFICATION” as listed in Schedule ‘A’ Part - IX representing __________ % _________________ percent Above / Below the lump sum price of ₹9,47,499.00 inserted by the MES in Schedule ‘A’ Part - IX |
| 11 | Schedule 'A' Part - XThis Schedule is not prepriced by MES and the prepriced rate indicated in Col - 5 as `0.00 indicates this fact only. The tenderer is required to quote their rates in Column 6. This Schedule constitutes Sl. Item Nos. 10 to 71 |
| 12 | B/R WORK SERVICES FOR DATA CENTRE FACILITYS&F, 5.5mm thick wave free toughened clear glass for fixing in uPVC window complete all as specified and directed. |
| 13 | S&F in repairs venetian blinds vertical type 100mm width with approved fabric and powder coated aluminium fittings such as top rails, metal weight nylon button loops etc to match with the top rail metal base complete all as specified and directed. |
| 14 | M&L Surface preparation including putty application.Providing and applying two coats of flame shield primer followed by two coats of flame shield finsh paint. Oil modified alkyd paint, smooth & glossy finishes, % volume 42.0 + 2.0, Theoretical VOC (gms/ltr) 440-500 (depending on shade), white and a wide range of tinable shades, smooth uniform, free following, and suitable for brushing (80-120 Sec at 30 degree C, Ford Cup B4), Berger G.P. Thinner (800), Brushing: 70-80 Sec, Spraying 45-50 Sec, Brush, roller or spray, Theoretical Spreading Capacity 10-12 Sqm/Ltr/Coat, Surface Dry: Less than 5hrs (at 16-22m DFT) Hard Dry: Less |
| 15 | than 18 hrs (at 16-22m DFT), Over coating interval: 18-24 hrs (Depending on ambient temp), Primer: Flame Shield Primer (Preferably two coats with an interval of 16 to 18 hrs). Ensure that the surface is free from dust, dirt loose particle & moisture, remobe existing paint, one or two coat of primer for best results, it is advisable to give 12-14 hrs drying time before application of subsequent coats. D not over thin. Stir well before use. Top coat combining the attributes of resistance against flame and moderate gloss |
| 16 | including removing existing surface finishes for PRIMER COAT: Oil modified alkyd paint, smooth glossy, Flame Shield Primer (Preferably two coats with an interval of 16 to 18 hrs) complete all as specified and directed. |
| 17 | S&F, 12mm thick wave free toughened clear glass door with stainless steel fitting, fish mouth channel in bottom and top as per design with and including provision of all other neccessary fixture and accessories, complete all as specified and directed. |
| 18 | S&F in repair aluminium (extruded section body) body door closer hydraulically regulated, designation No 3, universal type, suitable for door shutters of 851 to 1000mm in width & of weight between 61 to 80kg fixed in repairs complete all as specified and directed. |
| 19 | Providing and fixing Automatic sensor double door each leaf weight 100kg width of doors = 700-1200mm opening speed 400mm/s closing speed 300mm/s Door Hold Time = 0.5 to 10 sec. Manual Thrust 45N Supply voltage = AX 220 V Track Dimensions : WXHXL = 130mm x 62mm x 2200/2400mm complete wiring and switches with full accessories complete all as specified and directed. |
| 20 | B/R PORTION (02 Nos COVER SHEDS)S&F, pre-painted galvalume aluminum zinc coating profiled steel sheet 0.50mm thick (total coated thickness as per IS:15965) of an colour having tensile strength of 550 Mpa as in roof covering / cladding to wall, fixed with self tapping complete all as specified and directed. |
| 21 | Note: It shall be coated with hot dip alloy of 55% aluminium 43.5% zinc 1.5% silicon and finished with resin coat on both surfaces @ 150gm/sqm of coating (total both surfaces) having overall width and laid width as specified and shall be fixed using hot dip galvanised, self-tapping screws neoprene and EPDM washers. Penetrations and laps in sheet shall be sealed by using proper sealant profile. HDFE fillers shall be provided wherever required to close voids between sheets, sheet & fasteners etc., fixing system shall be as per manufacturers instructions and shall be safe against effects of wind velocity. |
| 22 | S&F, pre-painted galvalume aluminum zinc coating plain steel sheet 0.50mm thick (total coated thickness as per IS:15965) of any colour having tensile strength of 550 Mpa as in roof covering / cladding to wall, fixed with self tapping screws complete all as specified and directed. |
| 23 | Note: It shall be coated with hot dip alloy of 55% aluminium 43.5% zinc 1.5% silicon and finished with resin coat on both surfaces @ 150gm/sqm of coating (total both surfaces) having overall width and laid width as specified and shall be fixed using hot dip galvanised, self-tapping screws neoprene and EPDM washers. Penetrations and laps in sheet shall be sealed by using proper sealant profile. HDFE fillers shall be provided wherever required to close voids between sheets, sheet & fasteners etc., fixing system shall be as per manufacturers instructions and shall be safe against effects of wind velocity. |
| 24 | INTERNAL ELECTRIFICATIONTaking down carefully unserviceable aluminium / copper point wiring (light, fan, socket or power) complete with fittings such as switches, sockets, ceiling rose, light fittings etc, removing all material for reuse / issued under sch of credit and making good the distrubed surface as the existing one, complete all as specified and directed. |
| 25 | Taking down old sub main wiring of any type and size complete all as specified and directed. |
| 26 | M&L for PVC insulated, unsheathed, multistranded copper conductor cable, 1100 Volts, FRLS grade, ISI marked of size 2 core x 10 sq.mm drawn through in and including suitable PVC non matallic rigid casing / caping with accessories fixed on walls / roofs / floors / ceiling etc. and connecting terminal ends including complete all as specified and directed. |
| 27 | M&L for PVC insulated, unsheathed, multistranded copper conductor cable, 1100 Volts, FRLS grade, ISI marked of size 4 core x 35 sq.mm drawn through in and including suitable PVC non matallic rigid casing / caping with accessories fixed on walls / roofs / floors / ceiling etc. and connecting terminal ends including complete all as specified and directed. |
| 28 | M&L for PVC insulated, unsheathed, multistranded copper conductor cable, 1100 Volts, FRLS grade, ISI marked of size 4 core x 50 sq.mm drawn through in and including suitable PVC non matallic rigid casing / caping with accessories fixed on walls / roofs / floors / ceiling etc. and connecting terminal ends including complete all as specified and directed. |
| 29 | M&L for maintenance free chemical earthing complete with copper earth plate 90cm x 60cm x 5mm thick buried directly in ground with copper bonded electrode of dia 17.2mm rod (earth pit not less than 3mtr deep below ground level) with top edge of the plate not less than 2.10mtr below normal ground level, connected to and including copper earth strip of 32 x 6mm by means of rivetting and brazing and protected by GI pipe light grade of suitable size up to the test point i.e. up to 7.5mtr, including providing alternate layers up to full volume of pit by low resistivity earth enhancement graphite and VNT GC compound & earthing backfill compound including electra pill carbon & betonies based compound with charcoal dust and common salt, |
| 30 | magnesium sulphate & vegetable soil all around the plate 15cm depth and width for getting the earth resistance and resistance value less than 1 Ohm and RCC cover, connecting to the test point and testing on ground complete and including excavation and earth work in any type of strata and cleaning of site all as specified in MES SSR Part-I and directed by Engineer-in-Charge. |
| 31 | LED Batten light (System lumen efficacy ≥ 120 <135 lm/Watt) Supplying, installation, testing & commissioning of LED surface mounted batten light 10 watts of following body material and construction as per IS:10322 with driver (Replaceable) as per the requirement with Driver efficiency >85%, Operating voltage AC 140-270 Volt, frequency 50/60 hz, Operating temp range-5oC to 40oC, internal surge protection of 2.5 KV with Short & Open |
| 32 | circuit protection, THD < 10%, P. F.≥ 0.95, IP20, CRI >80, Flicker free (flicker should be below 5%), life time (LED, driver & electrical circuitry), of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends, CCT 3000°K / 4000°K / 5700°K / 6500°K (as per ANSI Bin), SDCM (Standard Deviation Colour Matching) < 3, maximum power consumption should not more than the specified rating and fixture shall be of relevant BIS standard. Manufactures Word Mark / Name Engraved / Embossing / Screen printing on housing complete in all respect including external connections with 1.5 sq.mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required with minimum |
| 33 | 5 year OEM warranty. System lumen efficacy ≥120 <135 lm/Watt output. LM79 & LM80 test report and all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C). Powder coated die cast / extruded aluminium body (Thickness > 1.20mm). |
| 34 | S&F, exhaust fan metal body AC single phase 230V of size 300mm sweep with blades, frame and louvers complete all as specified and directed. |
| 35 | ROAD / PATH / CULVERT / HARDSTANDINGProviding and laying at or near ground level factory made kerb stone of M-25 grade cement concrete in position to the required line, level and curvature, jointed with cement mortar 1:3 (1 cement : 3 coarse sand), including making joints with or without grooves (thickness of joints except at sharp curve shall not to more than 5mm), including making drainage opening wherever required complete all as specified and directed. |
| 36 | Preparation of new concrete surfaces of any description over 10cm in width or girth and applying two coats of synthetic enamel paint over a coat of primer complete all as specified and directed. |
| 37 | M&L for rendering 15mm thick stone masonry wall surfaces in CM 1:4 finished even and smooth without using extra cement complete all as specified and directed. |
| 38 | S&F, 110mm bore PVC (SWR) pipes single socketed, in any length with rubber ring joints, laid in trenches or in floors complete all as specified and directed. |
| 39 | M&L for sand filling under floor including watering, consolidation and well ramming complete all as specified and directed. |
| 40 | SEWAGE DISPOSALProviding and laying non-pressure NP2 class (light duty) 150mm dia RCC pipe with collars jointed with stiff mixture of cement mortar in the proportion of 1:2 (1 cement : 2 fine sand) including testing of joints complete all as specified and directed. |
| 41 | EXTERNAL ELECTRIFICATIONDesign, supply & fixing of 11KV 3 way Ring Main Unit (RMU) 630Amps, 21KA/3 Sec Motorised outdoor type both side extensible type comprising of 03 outgoings fixed type SF6 insulated VCB. All light parts bus bars VCB connection of RMU max two modules shall be enclosed in single tank duly welded stainless steel tank of 2mm thickness having IP 67 degree of protection filled with gas as insulation with leakage rate less than 0.1% per year tested as per IEC 62271-200. RMU shall be complete with all accessories such as ring core CTs self powered micro process based numerical protection relay for O/C, S/C, E/F, cable support, all front cable |
| 42 | terminations, mechanical indication for breaker ON / OFF / Trip / Spring charged, Mono meter as per IEC standards 62271-200 including any civil works as required complete all as specified and as directed by Engineer-in-Charge. The each VCB module should consist of following accessories: -03 NO'S OUTONGING SF6 VCB'S(a) 630 A, 350 MVA VCB module for making and breaking fault current along with OFF load isolator in series for isolation purpose and integral series earth switch of full making capacity.(b) Short time current - 21 KA/3 Sec.(c) Making capacity - 52.5 kA.(d) Auxiliary Contacts - 1 NO + 01 NC. |
| 43 | (e) Impulse voltage withstand voltage - 75 KV.(f) Nominal operating gas pressure - 1.3-ABS.(g) Front cover Mechanism - IP 2X.(h) Cable cover - 4X.(j) Degree of protection - IP 54.(k) Internal arc type tested 21KA/1s.(l) 24 volts DC motorized spring charging mechanism for breaker operation.(m) Push button for breaker ON/OFF.(n) Cable box for front termination of the cable suitable for up to 1 run of 3 core 95 or 120Sqmm, 11 KV XLPE cable.(o) Push ON type right angle Boots. |
| 44 | (p) Current Transformer (50/1, 2.5 VA, 5P10) for protection, Current Transformer (50/1, 2.5 VA, 0.5) for metering and 1 No Coupling Kit. (q) Self powered micro processor based relay 3 O/C 01 E/F with low and high set for over current and earth fault. Relay should have facility to display the maximum loaded current also. Relay should be flush mounted for incoming and outgoing VCB to trip the breaker from remote commands without shunt trip coil along.(r) Panel mounted 11 KV ring core CTs 50-100/1A, Class: 5P10, 2.5VA for protection as per IEC 50185.(s) Capacitive voltage indication fixed type system as per IEC 61243. Please Enable Macros to View BoQ information |
| 45 | (p) Current Transformer (50/1, 2.5 VA, 5P10) for protection, Current Transformer (50/1, 2.5 VA, 0.5) for metering and 1 No Coupling Kit. (q) Self powered micro processor based relay 3 O/C 01 E/F with low and high set for over current and earth fault. Relay should have facility to display the maximum loaded current also. Relay should be flush mounted for incoming and outgoing VCB to trip the breaker from remote commands without shunt trip coil along.(r) Panel mounted 11 KV ring core CTs 50-100/1A, Class: 5P10, 2.5VA for protection as per IEC 50185.(s) Capacitive voltage indication fixed type system as per IEC 61243. Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Jul 27, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedAug 17, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.