Tender For Repair / Replacement Of E/M Services And Allied Works To Ac, Heating Plants At Certain Location Under Ge (Af) Srinagar.
Tender Value
28 Lakhs
Estimated cost
Bid Submission
17 Aug 2026
19 days left
EMD
56000
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Budgam → Jammu and Kashmir
EMD Exemption
Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender for Repair / Replacement Of E/M Services And Allied Works To Ac, Heating Plants At Certain Location Under Ge (Af) Srinagar.
BOQ
| Sl. No. | Item Description |
| 1 | Supply and erect in true vertical position 11.00m long steel tubular swaged poles complete with cast iron base plate, finial plug, bolts, nuts & screws as specified type 410 SP-55, painting of exposed surface of pole with two coats of aluminium paint over one coat of red oxide primer, painting up to 1.20m height above coping in alternate band ( 20 cm wide strip) with two coat synthetic enamel paint over one coat red oxide primer, marking Pole No. in 10cm dia coloured yellow circle, painting of pole below ground level with two coat anticorrosive paint including taking down old swaged pole, complete all as specified and directed. (Note:- Excavation, earth work and PCC will be measured and paid separately in respective items.) |
| 2 | M&L for PCC, 1:4:8, type D-2 (using 40 mm graded crushed stone aggregate) as in foundation filling / mass concrete etc., complete all as specified and directed. |
| 3 | M&L for plain cement concrete 1:3:6, type C-1 (using 20 mm graded crushed stone aggregate) as in coping for pole and the like, weathering, slightly rounded or chamfered angles including necessary form work, complete all as specified and directed. |
| 4 | S&F in repairs 210 Watt LED flood light, 230 V AC outdoor type with thermal management in multiple optics and equipped with IP-66 protection, with impact and corrosion resistant complete with driver and lamp, complete all as specified and directed. |
| 5 | S&F in replacement PVC insulated cu stranded (FRLSH) wire 2.5 sqmm, passing through the non metallic PVC conduit from junction box to LED security light terminals. All connections should be made with proper size of thimbles, complete all as specified and directed. |
| 6 | S&F in replacement of Rigid non-metallic PVC conduit of size 20mm dia exclusive of boxes (junction / terminal) but inclusive of all tees, bends, elbows, reducers, bell mouth tube ends and fixing accessories such as couplers, lock nuts, saddles, pipe hooks etc., complete all as specified and directed. |
| 7 | S&F in replacement PVC weather proof junction boxes of size 250 x 200 x 100mm (Inside dimentions) with PVC connector heavy duty connector 4 way 16 amps ,one No MCB SP 6 Amps and making necessary cable connection, complete all as specified and directed. |
| 8 | S&F in repairs LED post top light fitting 40W with all fixing accessories fitted on pilar or poles including making suitable foundation for anchoring in PCC 1:2:4, type-B-1, complete all as specified and directed. |
| 9 | Surface dressing / cleaning of surrounding area of 2/4 pole structure, TR plinth sub stn including removing of tree branches, small tree plants, tarbushes etc., complete all as specified and directed. |
| 10 | Labour for cutting the bushes and plants grown near the substation / structures premises using necessary tools and plants and removing the plants from the root level at any depth and cleaning the premises completely and making good the site suitable for spreading the stone aggregate including disposing all the waste to a distance not exc 50m form the site, complete all as specified and directed. |
| 11 | S&F in repairs MCCB 4 pole 415 volts fixed type 100 Amps with breaking capacity 16 KA, complete all as specified and directed. |
| 12 | S&F in repairs MCCB 4 pole 415 volts microprocessor release type, 160 Amps with breaking capacity 36 KA, complete all as specified and directed. |
| 13 | S&F in repairs MCCB 4 pole 415 volts microprocessor release type, 200 Amps with breaking capacity 36 KA, complete all as specified and directed. |
| 14 | S&F in repairs MCCB 4 pole 415 volts microprocessor release type, 250 Amps with breaking capacity 36 KA, complete all as specified and directed. |
| 15 | S&F in repairs MCCB 4 pole 415 volts microprocessor release type, 400 Amps with breaking capacity 50 KA, complete all as specified and directed. |
| 16 | S&F in repairs MS chequered plate of 6 mm thick confirming to FE-290 grade 165 including provision of lifting handle for each plate on existing cable ducts and manhole covers for semi under ground sumps including painting with two coats of synthetic enamel paint over a coat of red oxide primer, complete all as specified and directed. |
| 17 | Supply, laying, jointing and testing XLPE insulated of cross sectional area 10 Sqmm 4 Core, PVC inner sheathed, armoured with galvanised steel strip or wire, heavy duty, LT underground cable ISI marked with aluminium conductor 1100 volt grade laid in trenches / duct passing through pipe / duct or fixed on pole and connecting and testing etc including taking out existing old unserviceable cable, complete all as specified and directed.Note:- Earthwork, sand cushion, cable cover if required will be measured and paid separately under respective items of this Schedule. |
| 18 | All as per Ser item No 17.00 here in above but cross sectional area 16 Sqmm 4 core. |
| 19 | All as per Ser item No 17.00 here in above but cross sectional area 25 Sqmm 3.5 core. |
| 20 | All as per Ser item No 17.00 here in above but cross sectional area 95 Sqmm 3.5 core. |
| 21 | All as per Ser item No 17.00 here in above but cross sectional area 120 Sqmm 3.5 core. |
| 22 | M&L for cutting the existing bituminous / hard Standing road surfaces and making good disturbed portion for laying of cable / GI pipe etc. and providing 100mm thick plain cement concrete, 1:2:4, type B-2 (using 20 mm graded crushed stone aggregate) for filling up the area of road cutting surfaces and making good the disturbed surface with existing surface, complete all as specified and directed . |
| 23 | Excavation in trenches, n. exc 1.5 m wide and n. exc 1.5m depth and getting out in for foundation of pole, stay, laying of cable and pipe in any type of soil etc all as specified and directed |
| 24 | Excavation in trenches, n. exc 1.5 m wide and exc 1.5m but n exc 3.0m depth and getting out in for foundation of pole, stay, laying of cable and pipe in any type of soil etc all as specified and directed |
| 25 | Removing excavated material to a distance n.exc 50 m & depositing where directed at a level n. exc 1.50 m above the starting point, complete as specified and directed. |
| 26 | Returing, filling in incl spreading, levelling, watering and well ramming in layers n exc 25cm thick after laying of the cables,jointing & testing complete all as specified and directed. |
| 27 | M&L for laying of bricks well burnt sub class B (old size) laid flat for cable protection width equal to the length of bricks, complete all as specified and directed |
| 28 | M&L for sand cushioning in trenches spreading and consolidation 8 cm thick before laying the cable and 15 cm of the sand after laying the cable but will be measured 18 cm after punning etc., complete all as specified and directed. |
| 29 | S&F in repairs 80mm dia GI tubing, light grade, with all fittings fixed on walls / poles for protection of cable including clamp 02 Nos of size 25x4 mm, nut bolts, washers etc, complete all as specified and directed. |
| 30 | S&F in repairs 100mm dia GI tubing, light grade, with all fittings fixed on walls / poles for protection of cable including clamp 02 Nos of size 25x4 mm, nut bolts, washers etc, complete all as specified and directed. |
| 31 | M & L for painting of steel tubular 4 pole structure of any capacity complete lenght, by applying one coat of white cement based paint after scraping / brushing and cleaning the Algae on pole and cross arms and a coat of white synthetic enamel painting to pole upto 1.5m from ground level shall be painted by alternate layer of black and yellow enamel paint (30 cms apart) and two coat of aluminium painting shall be done on cross arm and bracing, nut, bolts and washers etc after preperation of surfaces, complete all as specified and directed .Note - One 4 pole structure measured as one job inclusive of HT poles and cross arms complete. |
| 32 | M&L for earthing complete with galvanized steel earth plate electrode 600mm x 600mm x 6mm buried directly in ground vertically to a depth not less than 2.25 m below normal ground level (with top edge of earth plate not less than 1.5 metre below ground level) connected to galvanized iron earth strip 32 x 6 mm (main earthing lead) by means of galvanized bolts, nuts and washers all as shown in electrical plate No 3 of MES Schedule Part-I (2009) connected to earth test point & to main switch board with & including adequate quantity of charcoal dust and common salt alround earth plate & 40 mm dia GI pipe medium grade for earth lead protection pipe for suitable length and GI pipe 20 mm dia medium grade for watering pipe with funnel & wire mesh including necessary earth work and PCC (1: 3 : 6) type C-1 for earth pit , internal surface of concrete shall be given 10mm thick plaster in CM 1:4 and 40 mm thick precast RCC cover 1 : 2 : 4 ,type B-1( using 20 mm graded crushed stone aggregare ) reinforced with 8 mm dia TMT bars @ 75 mm c/c both ways with 12mm dia round bar as in handle including taking down of existing earthing, complete all as specified and directed. |
| 33 | NOTE : (i) The cost of earth lead and its protection pipe upto and including 7.5 m only from the top of earth electrode are deemed to be included under this item and additional earth lead , if any, required at site shall be measured and paid for separately under appropriate item of Schedule `A’/BOQ.(ii) Any joint in earth lead from earth electrode to test point shall not be allowed/permitted. |
| 34 | Deduction to be made from BOQ for Schedule 'A' Part-II (Credit Schedule from dismantling / taking down items) worth Rs 64,715.00 during AOC. (Note :- Tenderers shall not quote for this Schedule) Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Jul 27, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedAug 17, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 19 daysAug 19, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 21 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender