Defence Statutory Bodies & Commissions/Committees Closing in 18 days TDR #56689901

Tender For Repair / Maintenance / Cleaning Of Sewer Lines, Man Holes And Covers Spetic Tanks, Soakage Wells At Varunpauri-I, Ii & Uwr Area Under Ge (Nw) Vasco. (Tender Id No. 2026_Mes_781149_1)

Issued by Statutory Bodies & Commissions/Committees · goa, Goa
Tender Value
45 Lakhs
Estimated cost
Bid Submission
17 Aug 2026
18 days left
EMD
90000
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
goa → Goa
EMD Exemption
Available
Quantity
Not Available

Project Description

Tender for Repair / Maintenance / Cleaning Of Sewer Lines, Man Holes And Covers Spetic Tanks, Soakage Wells At Varunpauri-I, Ii & Uwr Area Under Ge (Nw) Vasco. (Tender Id No. 2026_Mes_781149_1)

BOQ

Name of Work:- REPAIR / MAINTENANCE / CLEANING OF SEWER LINES, MAN HOLES AND COVERS SPETIC TANKS, SOAKAGE WELLS AT VARUNPAURI-I, II & UWR AREA UNDER GE (NW) VASCO. (Tender ID No. 2026_MES_781149_1)
Sl. No. Item Description
1Cleaning of block in sewage line of 110/75mm dia by rodding from one MH to next MH and washing through in fresh water including removing all sludge from the sewage line and man hole including removing existing MH cover and Refixing properly after cleaning and disposed off sludge properly out side MD land all as directed(cleaning of manhole will be measured and paid separetly.
2All all as per item No 1 above but sewage line of 150 mm dia.
3All all as per item No 1 above but sewage line of 200 mm dia.
4All all as per item No 1 above but sewage line of 300 mm dia.
5Cleaning of manhole of any description of size n. exc 1.5 M in depth including lifting up and removing sludge and accumulated/ semi solid sludge and other foreign material with trailor mounted sewage cleaning pumps/mechanical devices and removing to a distange n. exc 250 m where directed by Engineer in charge & washing down with water for smooth function of sewage incl removal and refixing of manhole cover .
6All as per item No 5 above but manhole exc 1.5 M depth & n. exc 2 M .
7All as per item No 5 above but manhole exc 2 M depth & n. exc 4 M and -do-.
8Cleaning of septic tanks of 500 users capacity by bailing out water, removing sludge dust mud & other accumulated solids, semi solids etc including cleaning & sewage sludge and other materials deposited out side the MD land.
9All as per item No 8 above but septic tank of 250 user Capacity.
10All as per item No 8 above but septic tank of 150 user capacity
11Demolition of reinforced cement concrete cover slab for MH/Septic tank and removing the debris to a distance not exc 500 M as directed.
12M&L precast cement concrete 1:2:4 type B1 using 20 mm graded stone aggregate for cover slab for MH/Spetic tank set in CM 1:6 including formwork.
13M&L for 8 mm dia TMT bar cut to length, bend to shape required incl cranking bending & hooking ends & binding with MS wire annealed n. less 0.9mm dia.
14M&L for removal of blockage from WC by using rubber cup 125mm dia with wooden handle and clearing the blockage upto manhole with cleaning rod including removal of all materials from P trap of WC .
15M&L for removal of blockage from kitchen/bathroom /WHB by using rubber cup 125mm dia and clearing the blockage upto gully traps with cleaning rod including removal of all materials from floor trap including dismantling and refixing of gratings.
16Demolition of laterite stone/ block/ brick masonary walls built in CM and removing the debries to a distance not exc 500 M as directed.
17M&L for Pre-cast cement concrete block masonry Type C1 (20mm graded aggregate) with solid blocks, exc. 10 cm in width and setting in mortar 1:6 complete all as specified and directed.
18M&L rendering 10 mm thick in CM 1:6 on fair faces of brick work concrete surfaces finished even and smooth without using extra cement.
19Excavation in trenches n. exc 1.5 M wide & n. exc 1.5 M in depth for foundation in soft/disintegrated rock and getting out.
20All as per item No. 19 above but depth exc 1.5M and n.exc 3M.
21Demolition and breaking up of SGSW pipes set in cement mortar 200 mm dia
22All as per item No 21 but 150 mm dia pipe.
23All as per item No 21 but 100/110 mm dia pipe.
24Demolition of cement concrete(un-reinforced) of any description and in any position not otherwise specifically provided for
25M&L for Cement concrete (1:4:8), type D2 using 40mm graded stone aggregate as in filling, sub base of flooring complete all as specified and directed by Engr-in-charge.
26M &L 75 mm thick PCC 1:3:6 type C-2 as in sub base Floor Paving Plinth Protection finished even and fair complete all as specified and directed.
27M & L concrete bed to drain pipe and including packing under haunching against the sides & pipe and after they laid and tested in cement concrete 1:4:8 type D2 bore of pipe 200 mm dia.
28All as per item No 26 above but for 150 mm bore.
29All as per item No 26 above but for 100/110 mm bore.
30Supply and laying for 200 mm dia Double walled corrugated (DWC) pipes 15-30 mm thick SN-8,Conforming to IS 14930 heavy duty for sewerage lines with complete accessories laid and jointed complete all as specified and directed.
31Supply and laying for 150 mm dia Double walled corrugated (DWC) pipes 15-30 mm thick SN-8,Conforming to IS 14930 heavy duty for sewerage lines with complete accessories laid and jointed complete all as specified and directed.
32M & L PVC (SWR) pipes110mm bore single socketed in any length with rubber ring joints laid in trenches or in floors and jointed as specified.
33Returning filling in including spreading levelling watering and well ramming in layers n.exc 25 Cm thick in soft/disintegrated rockl complete all as specified and directed.
34Removal of excavated soft disintegrated rock to a distance n. exc 50M and deposited where ddirected at a level n. exc 1.5 M above the starting point.
35Dismantling old CI/PVC drain pipe 110/75 mm dia and taking out from walls/ trenches if required.
36S & F PVC (SWR) pipe 110 mm dia single socketed in any length with rubber ring jointed, fixed to wall with necessary clamping.
37S & F PVC (SWR) pipe 110 mm dia single socketed in any length with rubber ring jointed, fixed to wall with necessary clamping in High rise bldg above 04 storey complete all as specified and directed.
38S & F PVC (SWR) pipe 75 mm dia single socketed in any length with rubber ring jointed, fixed to wall.
39S & F PVC (SWR) pipe 75 mm dia single socketed in any length with rubber ring jointed, fixed to wall with necessary clamping in High rise bldg above 04 storey complete all as specified and directed.
40M&L PVC (SWR) bends any radius 110 mm bore
41M&L PVC (SWR) bends any radius 75 mm bore
42M&L PVC (SWR) branch piece, single (Single Y) equal or unequal, 110 mm bore
43M&L PVC (SWR) branch piece, single (Single Y) equal or unequal, 75 mm bore
44M&L PVC (SWR) branch piece, double (double Y) equal or unequal,110 mm bore
45M&L PVC (SWR) branch piece, double (double Y) equal or unequal, 75 mm bore
46M&L PVC (SWR) branch piece, single (Single T) equal or unequal, 110 mm bore
47M&L PVC (SWR) branch piece, single (Single T) equal or unequal, 75 mm bore
48M&L PVC (SWR) vent cowl 75mm bore
49M&L PVC (SWR) vent cowl 110mm bore
50S&F in repair PVC (SWR) floor trap, plain with grating including jointing with solvent cement diametr of outlet 75mm
51S&F in repair PVC (SWR) gully trap 125/110 mm, setting and jointing with solvent cement
52M&L taking up or down old covers and setting in cement mortar 1:3 and flaunching with cement concrete 1:2:4 type B1 cast iron/RCC manhole covers and frames medium duty all as directed
53S&F in repair waste fittings 32/40mm , brass, chromium plated for glazed ware sinks/stainless steel sinks/WHB with long screwed shanks and flynuts, flange end bedded in red lead cement concrete
54S&F in repair vitreous china wash basin flat back size 600 x 480 mm white, excluding taps waste, chain and plug and porcelain stopper but including brackets
55S&F waste fittings 32/40mm , brass, chromium plated for glazed ware sinks/stainless steel sinks/WHB with long screwed shanks and flynuts, flange end bedded in red lead cement concrete
56S&F PVC waste pipe 32mm/40mm dia for wash basin and kitchen sink fixed in repairs complete all as specified and as directed.
57S&F PVC waste pipe 32mm/40mm dia for wash basin and kitchen sink fixed complete all as specified and as directed.
58S&F in repair plastic water closet seat cover for EWC, black closed pattern with flat bottom, and cover and mild steel chromium plated or aluminised hinging device
59S&F stainless steel gratings in repair 125mm dia with cement mortar 1:2 and matching with existing floor
60Supply & Fix WC of size 580 x 440 mm vitreous china squatting pan, Orissa pattern white with \\"P\\" or \\"S\\" trap front or back inlet and integrated foot rest including provn of lime concrete bedding etc fixed in repairs.
61S & F in repair PVC high level /low level flushing cistern, 10 Ltrs capacity including float valve , chain, PVC flush pipe 32mm dia including dismantling of old unserviceable flush tank.
62S & F 15mm dia bib taps standard of PTMT any colour high pressure screwed for iron/cpvc pipe (min weight 90 gms) fixed in repairs.
63S&F pillar tap PTMT of any colour high pressure screwed for iron pipe and fixed 15mm dia (minimum weight 110 gms)
64S & F in repair pillar tap PTMT of any colour high pressure screwed for iron/cpvc pipe and fixed 15mm dia (minimum weight 110 gms)
65S & F 15mm dia CP bib taps fancy type long body cast copper alloy with crutch or butterfly handle screwed down for iron/cpvc pipe fixed in repairs.
66S &F 15mm stop valves PTMT any colour high pressure screwed for iron/cpvc pipe (min weight 90 gms) fixed in repairs .
67S &F 15mm angle stop valves PTMT any colour high pressure screwed for iron/cpvc pipe (min weight 90 gms) fixed in repairs .
68S&F Vitreous china wash down water closet (Pedestal pattern) (EWC) white, including fixing complete with ‘P’ or ‘S’ trap, fixed as in repairs complete all as specified and as directed.
69S&F PVC connection, 450mm long with brass CP check nuts suitable for connecting 15mm dia pipes, superior quality fixed in repairs, complete all as specified.
70S &F 15mm Ball valves PTMT any colour high pressure with epoxy coated aluminium rod and high density plastic ball screwed for iron/cpvc pipe (min weight 90 gms) fixed in repairs .
71S&F in repairs Brass CP mixer (Wall/pillar) for mixing hot & cold water screwed down for iron pipe and fixed
72Treating and finishing the sunken portion of WC area n.exc 1.5 sqm each by sealing the edge of hole through which pipes are entering the sunken portion , using seal tape and grout the gapes using a non-shrink cementitious grout (Dr fixit , /STP/Krishnaconchem) provinding 10 mm thichk rendering in CM 1:3 with and including water proofing compund. Apply first two coat of WPC (cementitious products with acrylic emulsion polymer as binder using Dr fixit pidifin 2 K of pidilite industries or equivalant of Focrock /Krishna conchem) in the sunken portion and extended up to 15cm on the wall above the FFL . Immediately cover all the angle fillets with a 150 mm wide strip of ope woven glass fiber mesh of 2mm x 2mm . Apply the sencond coat of WPC after the first coat dry completely, providing necessary connection items suitable for wc , providing lime concrete complete all as specified as per manufracture instruction and as directed by Engr in charge. (WC measured separately)
73As per item No. 63 above but for bath/lobby without any PVC connection , fitting for area exceeding 1.5 sqm each
74Taking up or down steel/cpvc water tubing 20mm bore and connections.
75Taking up or down steel/cpvc water tubing 25/32mm bore and connections.
76M/L CPVC pipes SDR 11 Class 1 laid in walls/ceiling or laying in floors outer dia 20mm dia including all fittings (Rates incl for making hole groves as applicable)
77M/L CPVC pipes SDR 11 Class 1 laid in walls/ceiling or laying in floors outer dia 25mm dia including all fittings (Rates incl for making hole groves as applicable)
78M/L LDPE pipes of pressue rating 6kgf/cm2 laid in walls/ceiling or laying in floors outer dia 32mm dia including all fittings (Rates incl for making hole groves as applicable)
79Dismantling floor, hearth or wall tiling incl cement mortar bedding ( but not backing), removing serviceable tiles to store and rubbish off the premises.
80M&L screed bed or bedding layer of mortar 15mm thick to receive floor tiles in cement plaster 1:6 complete all as specified and as dircted
81S & F Non skid coloured ceramic tiles of size 300 x 300 x 7 mm thick in floors etc, set and jointed in neat cement slurry and pointed in/hite/coloured cement to match all as specified.
82S & F Non skid coloured ceramic tiles of size 400 x 400 x 7 mm thick in floors etc, set and jointed in neat cement slurry and pointed in/hite/coloured cement to match all as specified.
83M&L rendering 10mm thick in CM 1:4 on brick work/ concrete surface to receive tiles
84S & F glazed ceramic tiles, coloured of size 350 x 250 x 7/450x350x7 mm thick with on vertical surfaces such as dado, skirting etc, set and jointed in neat cement slurry and pointed in white cement to match all as specified.
85S&F in repair Health faucet (ABS body) mild steel cp suitable for 15mm dia pipe with 1.25m long flexible tube and ABS wall hook incl making connections and fixed in position complete all as specified and directed.
86S&F 15mm in repair dia two way cock PTMT of any colour high pressure screwed for iron/CPVC pipe (min wt 90gms) complete all as specified and directed.
87S&F in repair EWC jet spray (Regular type) (1.5m) Stainless steel grade 304 Jet spray built in installation type complete all as specified and directed.
88S & F in repairs Vitreous China urinals, bowl type (back or corner wall type), complete including providing and fixing plugs, bedding urinal against wall in cement mortar 1:2, securing urinal to plugs with and including 60mm long brass screws, pointing around urinal back in cement; fixing automatic flushing cistern with brackets, flush pipe, grating and Union for discharge pipe. (Including of fixing supply pipe to flushing cistern, trap and waste pipe)
89Disconnecting existing tanks, setting aside & Cleaning of storage water tank of PVC/HDPE exc. 250 ltrs but n. exc 500 ltr capacity staged over RCC roof/floor slab or similar place inside /outside bldgs by removing float valves carefully, thoroughly cleaning the wall, floor and ceiling of the tanks, mouth of pipe etc, removing the dirty water, sludge and other depositions to a distance not exceeding 50 mtr to make the tank totally dirtfree and finally cleaning the water tank with fresh water till water becomes clear to entire satisfaction of Eng-in-Charge and as specified in particular specification and refixing of float valves all as specified and directed
90All as per item no 89 above but water tank of capacity nexc 250 ltrs.
91All as per item no 89 above but water tank of capacity exc 500 ltr but n. exc 1000 ltrs
92All as per item no 89 above but water tank of capacity nexc 250 ltrs above 04 storeys
93S& F PVC water tank covers circular type with suitable nut and bolts complete for water tanks of 200 to 2000 ltr capacity complete all as specified and as directed.
94NOTE :- For Sr.No.- 1 to 7 & 14, 15(i) The Rep of contractor shall receive complaints in morning 0900 hr and give feedback on daily basis to concerned JE B/R or AGE B/R.(ii) All T&P, safety gadgets shall be provided by the contractor. (iii) Contractor shall maintain the maintinance register showing all daily complaints recieved and shall maintain job cards for attending complaints. The signature of the user shall be obtained on the job card after completion of the job with date.(iv) Contractor shall be penalised @ Rs.100/- per day per complaint, if he fails to attend the complaint within 12 hours.(v) Payment of executed quantity in respect of BOQ items released to contractor after submission of these complaints duly rectified within time and duly signed by contractor, JE and Engineer-in-Charge in RAR/Final bill. Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 56689901
AUTHORITY Statutory Bodies & Commissions/Committees
TENDER VALUE 45 Lakhs
LAST DATE 17-08-2026
Authority
Authority Name Military Engineer Services
Work Description Tender for Repair / Maintenance / Cleaning Of Sewer Lines, Man Holes And Covers Spetic Tanks, Soakage Wells At Varunpauri-I, Ii & Uwr Area Under Ge (Nw) Vasco. (Tender Id No. 2026_Mes_781149_1)
Basic Detail
Tender No 8250/E8
Bidding Type Tender
Location
City goa
State Goa
Key Dates
Publish Date 27 Jul 2026
Submission Date 17 Aug 2026
Open Date 24 Aug 2026
Finance
Tender Value 45 Lakhs
Tender Fee 500
EMD 90000
Exemption Available
Document List
8250Tenderdocuments.pdf
BOQ_875068.xls
daef2a24-08f5-4458-9475-d63869098c60.html
Tendernotice_1.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Jul 27, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Aug 17, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 18 days
Aug 24, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 25 days

Tender Documents

Download All (ZIP) ↓
pdf

8250Tenderdocuments.pdf

xls

BOQ_875068.xls

html

daef2a24-08f5-4458-9475-d63869098c60.html

pdf

Tendernotice_1.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail
Loading tenders