Public Administrative Department Local Bodies Closing in 6 days TDR #56689338

Tender For Municipal Council Banswara Construction Of Convention Centre Schem Shyama Prasad Mukharaji

Issued by Local Bodies · Banswara, Rajasthan
Tender Value
4.99 Crore
Estimated cost
Bid Submission
06 Aug 2026
6 days left
EMD
9.98 Lakhs
Bank guarantee accepted
Document Fee
5000
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Banswara → Rajasthan
EMD Exemption
Available
Quantity
Not Available

Project Description

Tender for Municipal Council Banswara Construction Of Convention Centre Schem Shyama Prasad Mukharaji

BOQ

Name of Work:- Municipal Council Banswara construction of convention centre SCHEM SHYAMA PRASAD MUKHARAJI
Sl. No. Item Description
1Clearing jungle including uprooting of rank vegetation, grass, brush wood, trees and saplings of girth upto 30 cm measured at a height of 1 m above ground level and removal of rubbish upto a distance of 50 m outside the periphery of the area cleared
2Earth work in excavation by mechanical means (Hydraulic Excavator )/ manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan) including dressing of sides and ramming of bottoms, lift upto 1.5 m, including taking out the excavated soil and depositing and refilling of jhiri with watering & ramming and disposal of surplus excavated soil as directed with in a lead of 50 meter. All kinds of soils
3Filling available excavated earth (excluding rock) in trenches, plinth side of foundation etc. in layers not exceeding 20 cm. in depth, consolidating each deposited layer by ramming and watering including lead up to 50 meter and with all lift.
4Diluting and injection Chloropyrifos Emulsifiable concentrate 20% with 1% concentration for PRE-CONSTRUCTIONAL Anti termite treatment as per IS 6313 part III as amended from time to time and creating a continuous chemical barrier under and around the column pits, wall trenches, basement excavation, top surface of plinth filling, junction of wall and floor along the external perimeter of building expansion joints, over the top surface of consolidated earth of which aproch is to be laid surrounding of pipes and conduits etc. complete as per specification (Plinth floor area only shall be measured for payment and excluding the cost of chemical emulsion)
5Supplying chemical emulsion in sealed containers including delivery as specified.Chlorpyriphos/Lindane emulsifiable concentrate of 20%
6Providing and laying in position cement concrete including curing, compaction etc. complete in specified grade excluding the cost of centering and shuttering - All work up to plinth level. 1:4:8 (1 cement : 4 coarse sand : 8 graded stone aggregate 40 mm nominal size).
7Random Rubble stone masonry for with hard stone in foundation and plinth in Cement Sand mortar above 30 CM thick wall in:Cement Mortar 1:6 ( 1-Cement : 6-Sand).
8Random rubble dry stone Kharanja under floor
9sand filling under floor UNDER FLOOR AREA (268.28/0.20)=1341.4 sqm
10Providing and laying in position cement concrete, includingcuring,compaction etc.complete inspecifie dgrade excluding hecostofcenteringandshuttering-Allworkuptoplinthevel.1:3:6(1cement :3coarsesand:6gradedstone aggregate20mm nominal size).
11Centering and Shuttering with plywood or steel sheets including strutting, propping bracing both ways and removal of formwork for foundation , footings, strap beam, raft , bases of columns etc.
12Centering & shuttering with plywood or steel sheets including strutting, propping bracing both ways with steel props and removal of formwork for upto floor five level for :Columns, pillars, posts and struts etc.
13Providing and fabricating reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding (including cost of binding wire) all complete up to floor five level. ('Original producers' who manufacture billet directly from iron ores and roll the bilets to produce steel conforming to IS:1786)Thermo-mechanically Treated bars (Conforming of relevent IS code)
14Providing and laying in position specified grade of cement concrete for all RCC structural elements upto plinth level including curing, compaction, finishing with rendering in cement sand mortar 1:3 (1 cement: 3 coarse sand) and making good the joints and cost of plastizers( if required) excluding the cost of centering, shuttering and reinforcement.M20 grade Nominal Mix / Design Mix
15Add extra for providing richer mixes respectively at all floor levelsProviding M-25 grade concrete by using cement as per codal provision instead of M-20 grade design mix. QUANTITY SAME AS RCC QUANTITY =285.66
16Fine grinded Gangsaw cut 30-35 mm thick stone flooring over 20 mm (average) thick base of cement mortar 1:4 (1 cement :4 coarse sand) jointed grey cement slurry mixed with pigment to match the shade of stone complete as per design drawing and instruction of EI.Red sand stone (Karauli stone)
17Plaster on new surface on walls in cement sand mortar 1:6 including racking of joint etc. complete fine finish :20mm thick.( Internal plastr)
18Plaster on new surface on walls in cement sand mortar 1:6 including racking of joint etc. complete fine finish :20mm thick.( Internal plastr)
19Centering & shuttering with plywood or steel sheets including strutting, propping bracing both ways with steel props and removal of formwork for upto floor five level for :Suspended floors, roofs, landings, staircases, balconies, girders, cantilevers, bands, coping bed plates, anchor blocks, sills, chhajjas, lintel, beam, plinth beam etc.
20Columns, pillars, posts and struts etc.
21Providing and fabricating reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding (including cost of binding wire) all complete up to floor five level. ('Original producers' who manufacture billet directly from iron ores and roll the bilets to produce steel conforming to IS:1786)Thermo-mechanically Treated bars (Conforming of relevent IS code)Total qty of steel @ 130kg /cum
22Providing and laying in position specified grade of cement concrete for RCC structural elements upto floor five level including curing, compaction, finishing with rendering in cement sand mortar 1:3 (1 cement: 3 coarse sand) and making good the joints and cost of plastizers (if required ) excluding the cost of centering, shuttering and reinforcement for Walls (any thickness) including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc.M20 grade Nominal Mix / Design Mix
23Providing and laying in position specified grade of cement concrete for RCC structural elements upto floor five level including curing, compaction, finishing with rendering in cement sand mortar 1:3 (1 cement: 3 coarse sand) and making good the joints and cost of plastizers( if required) excluding the cost of centering, shuttering and reinforcement for Arches, arch ribs, domes, vaults, shells, folded plate, chimneys, shafts , roofs having slope more than 15º ,vertical and horizontal fins individually or forming box louvers, facias and eaves boards M20 grade Nominal Mix / Design Mix
24Add extra for providing richer mixes respectively at all floor levels Providing M-25 grade concrete by using min 410 kg of cement per cum instead of M-20 grade design mix.
25Brick work with mechanised autoclaved flyash lime bricks conforming to IS: 12894 :2002 of class designation 100 insuperstructure above plinth level upto floor V level in.Cement mortar 1 : 6 (1 cement : 6 coarse sand)ADD EXTRA FOR ORNAMENTAL WORK (2%)
26Half Brick work with mechanised autoclaved flyash lime bricksconforming to IS: 12894 :2002 of class designation 100 in superstructure above plinth level upto floor V level inCement mortar 1 : 4 (1 cement : 4 coarse sand)
27P & F 1st quality Heavy Duty Vitrified glazed MAT tiles on floor, skirting and steps etc.in different sizes (thickness minimum 10mm) with water absortion less than or equal 0.08% and conforming to IS 15622 of approved make in all colour and shade, laid with 20 mm thick CM 1: 4 including grounting the joints with white cement and matching pigment etc complete.size 600 mm X 1200mm
28Providing and fixing Granite stone slab mirror polished and machine edge cut in walls, pillars, steps, Shelves, Sills Counters, Floors etc. laid on 12mm (Av.) thick base of cement mortar 1:3 (1 cement : 3 coarse sand) jointing with white cement mortar 1:2 (1white cement : 2 marble dust) with pigment to match the shade of the marble slab including grinding, rubbing and polishing complete.Above 3601 Cm2 Slabs
29Extra for providing edge moulding to 15-18mm thick marble/ Granite stone counters, Vanities etc. including machine polishing to edge to give high gloss finish etc. complete as per design approved by Engineer-in-Charge. Granite/Kota Stone Work
30Full Edge moulding HALF Edge moulding
31Extra for providing opening of required size & shape for wash basins/ kitchen sink in kitchen platform, vanity counters and similar location in marble/Granite/stone work including necessary holes for pillar taps etc. including rubbing and polishing of cut edges etc. complete
32Providing and fixing 1st quality standard white, grey, ivory, fume red brown, light green, light blue and other light shades glazed tiles confirming to IS : 13753 & IS :15622 of size 200mm x 300mm in walls, floors, steps, pillars etc. laid on a bed of neat cement slurry finished with flush pointing in the white cement mixed with pigment to match the shade of the tile complete (excluding the cost of cement plaster on walls and pillar).
33Extra for using size above 200x300mm in glazed tiles and for using 400mm x 400mm MAT finished tiles in place of 300mm x 300mm size.
34Providing and fixing 1st quality MAT finished ceremic tile size 300x300mm confirming to IS : 13755 and IS : 15622 colour such as white, grey, ivory, fume red brown, light green, light blue and other light shades in floors, steps, pillars etc. laid on a bed of neat cement slurry finished with flush pointing in the white cement mixed with pigment to match the shade of the tile complete (including the cost of cement mortar bed 1:4).
35Extra for using size above 200x300mm in glazed tiles and for using 400mm x 400mm MAT finished tiles in place of 300mm x 300mm size.
36Providing and fixing aluminum work for doors ,windows, ventilators and partition with extruded built up standard tubular / appropriate Z sections and other sections of approved make conforming to IS :733 and IS :1285, fixed with rawl plugs and screws or with fixing clips ,or with expansion hold fasteners including necessary filling up of gap. at junctions , at top ,bottom and sides with required PVC/neoprene felt etc. Aluminium section shall be smooth ,rust free, straight ,mitered and jointed mechanically wherever required including cleat angle Aluminium snap beading for glazing /paneling , C.P. brass/ stainless steel screws Al. Tower bolt & Al. handle & Al. Aldrop etc.,all complete as per architectural drawings and the directions of Engineer- in – charge .(Glazing and paneling to be paid for separately).For fixed portion Powder coating aluminum ( minimum thickness of powder coating 50 micron) total weight (30*5.25kg/sqm)=157.50 KG
37For shutters builtup standard tubular sections of openable doors ,windows & ventilators including providing & fixing hinges / rollers etc. and making provision for fixing of fittings wherever required (lockes shall be paid for separately).Powder coating aluminum ( minimum thickness of powder coating 50 micron) Door & Windows openable
38Extra for shutters of sliding aluminum windowsTOTAL WEIGHT (70.7*8KG/SQM)=565.60 KG
39S&f fixed wire gauge of stainless steel of 14 mesh x 24 gauge to the aluminium window by Aluminium beading 20x3mm with suitable screws not exceeding 150mm distance at all heights with all lead and lift with scafolding.
40Providing and fixing 12 mm thick prelaminated three layer medium density (exterior grade ) particle board Grade I, Type II conforming to IS : 12823 bonded formaldehyde synthetic resin ,of approved brand and manufacture in paneling fixed in aluminium doors ,windows shutters and partition frames with C.P. brass / stainless steel screws etc. complete as per architectural drawings and direction of engineer-in-charge.Prelaminated particle board with decorative lamination on both sides.
41Providing and fixing glazing in aluminium door, window ,ventilator shutters and partitions etc. with PVS / neoprene gasket etc. complete as per the architectural drawings and the directions of engineer-in-charge.(Cost of aluminium snap beading shall be paid in basic item.)With float glass panes of 5.0 mm thickness ( weight not less than 13.50 kg/sqm)For fixed portion
42Extra for providing toughened glass panes instead of ordinary float glass panes in doors, windows and clerestory window shutters. (Area of opening for glass panes excluding portion inside rebate shall be measured).
43Providing and fixing double action hydraulic floor spring of approved brand and manufacture IS : 6315 marked, for doors including cost of cutting floors as required, embedding in floors and cover plates with brass pivot and single piece M.S. With stainless steel cover plate
44Providing and fixing 100mm brass locks (best make of approved quality) for aluminium doors including necessary cutting and making good etc. complete.
45Filling the gap upto 5 mm depth and 5 mm width in between aluminium frame & adjacent RCC/ Brick/ Stone work by providing weather silicon sealant over backer rod of approved quality as per architectural drawings and direction of Engineer-in-charge complete.
46Providing and fixing external grade board solid core single leaf flush door shutters ISI 2202-67 marked using Phenol formal dehyderesin in glue both sides with approved steel fittings complete as per annexure 'A' :35 mm thick .Decorative teak veneer One side
47Providing and fixing fullypanelled/partlypanelled/ double leaf shutter frames for doors as per approved design and drawingswithapprovedordinaryC.P./oxidisedsteel fittings asperAnnexure-'A'andwidthofstyles&toprailsof100mm and lock railswidthof 150mmandbottomrails of 200mm widthincludingteakwoodbeadingofsize19mmx12mmon both faces complete :8.4.1 35 mm thickIvory coast wood grade I
48Providing & Fixing mica of approved make for inner/outer side of shutters with fevicol & nails complete as per approved by engineer in charge.0.8mm thick mica
49Extra for providing other type of fittings as mention in annexure A ( as approved by EI) :Brass fittings (Ivory coast wood grade I AREA)
50Extra for providing other type of fittings as mention in annexure A ( as approved by EI) :Stainless steel fittings
51Extra for providing external lipping with 2nd class teak wood battens 6 mm minimum depth on all edges of shutters (over all area of door shutter to be measured) Over item no. 8.13.
52Extra for providing vision panel not exceeding 0.1 Sqm in all type of flush doors (cost of glass excluded) (overall area of door shutter to be measured) :
53Extra for cutting rebate in flush door shutters for making double leaf shutter(Total area of the shutter to be measured).
54Providing and fixing bright finished Mortice lock of approved make Godrej or equivalent with pair of CP handles for doors with necessary screws etc complete (Best make of approved quality) as per direction of Engineer-in-charge.
55Providing and fixing IS : 3564 marked Aluminium die cast body tubular type universal hydraulic door closer with necessary accessories and screws etc. complete.
56Providing and fixing M.S. sheet 1mm thick single leaf door shutter in angle iron frame 35x35x5mm suitabilly diagonally braced with 25x3mm flat iron above and below lock rail of size 50x5mm beading extra including all fittings, as per direction of Engg. incharge but excluding cost of chowkhats: including two coats of anit-corrosive red oxide primer pain
57Providing and fixing factory made P.V.C. door frame of size 50x47mm with a wall thickness of 5mm, made out of extruded 5mm rigid PVC foam sheet mitred at corners and joined with 2 Nos. of 150mm long brackets of 15x15mm M.S. square tube, the vertical door profiles to be reinforced with 19x19mm M.S. square tube of 19 gauge, EPDM rubber gasket weather seal to be provided through out the frame. The door frame to be fixed to the wall using M.S. screws of 65/100mm size complete as per manufacturers specification and direction of Engineer-in-Charge.Providing and fixing to existing door frames.
5830mm thick factory made solid both side Pre laminated panel PVC door shutter consisting of frame made out of M.S. tubes of 19 gauge thickness and size of 19mm x 19mm for stiles and 15x15mm top & bottom rails. M.S .frame shall have a coat of steel primers of approved make and manufacture M.S. frame covered with 5mm thick heat moulded PVC ‘C channel of size 30mm thickness, 70mm width out of which 50mm shall be flat and 20mm shall be tapered in 45 degree angle on either side forming stiles; and 5mm thick, 95mm wide PVC sheet out of which 75mm shall be flat and 20mm shall be tapered on the inner side to form top and bottom rail and 115mm wide PVC sheet out of which 75 mm shall be flat and 20mm shall be tapered on both sides to form lock rail. Top bottom and lock rails shall be provided either side of the panel. 10mm (5mm x 2) thick, 20mm wide cross PVC sheet shall be provided as gap insert for top rail & bottom rail. Panelling of 5mm thick PVC sheet to be fitted in the M.S. frame welded/ sealed to the stiles & rails with 7mm (5mm +2mm) thick x 15mm wide PVC sheet bending on inner side, and joined together with solvent cement adhesive. An additional 5mm thick PVC strip of 20mm width is to be stuck on the interior side of the ‘C Channel using PVC solvent adhesive etc. complete as per direction of Engineer-in-charge, manufacture’s specification & drawing.(For W.C.and bathroom door shutter).
59Plaster on new surface on walls in cement sand mortar 1:6 including racking of joints etc. complete fine finish :Plaster on new surface on walls in cement sand mortar 1:4including racking of joints etc. complete fine finish :12mm thick.( Internal plastr)
60Plaster on new surface on walls in cement sand mortar 1:6including racking of joint etc. complete fine finish :20mm thick (outer Plaster)
61Making grooves as per design in plaster 10mm to 20mm wide.
62Making of drip course (Tapka) in cement sand mortar 1:6 width upto 40 mm and 10 mm thick as per approved design
63Providing and applying white cement based putty over plastered surface to prepare the surface even and smooth complete (New plastered surface three or more coats)
64Wall painting with plastic emulsion paint of approved brand and manufacture to give an even shade including all scaffolding: Two or more coats on new work including prepartion of base with primer, putty, lippy etc complete in all respect.
65Finishing walls with textured exterior paint of required shade as per approved colour complete as per manufacturers specifications including primer coat and protecting coat including scaffolding and safety provision Trowel Finish av. thickness 1500 to 2000 microns. (30% of exter plaster quantity)
66RollerFinish av. thickness 400 to 500 microns. (70% of external plaster)
67Painting with synthetic enamel paint of approved brand and manufacture to give an even shade :
68Providing and fixing stainless steel railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners , stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in-charge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.).Grade 304
69Providing and fixing steel gate, grating , and grills made of angles, tees, square bars, flats,or black pipe with holdfast and fittings complete as per design and drawing including cutting welding and fabrication with priming coat of red oxide
70Providing and laying water proofing treatment in sunken portion of WCs, bathroom etc., by applying cement slurry mixed with water proofing cement compound consisting of applying : a) first layer of slurry of cement @ 0.488 kg/sqm mixed with water proffing cement compound @0.253 kg//sqm .This layer will be allowed to air cure for 4 hours.b) Second layer of slurry of cement @ 0.242 kg/sqm mixed with water proffing cement compound @ 0.126 kg/sqm This layer will be allowed to air cure for 4 hours followed by water curing for 48 hours.The rates includes preparation of surface treatment & sealing of all joints ,corners, junction with polymer mixed slurry.
71Grading roof for water proofing treatment with water proffing compound Cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size)
72Finishing with neat cement (punning)
73Providing gola 75x75 mm in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 stone aggregate 10mm and down gauge) including finishing with cement mortar 1:3 (1 cement : 3 fine sand) as per standard design :
74Providing and laying damp-proof course with cement concrete grade M-150 (1 : 2 : 4) mortar prepared with 1% solution of water-proof compound complete as per specification .50mm thick.
75Rough Chisel dressed Sand stone 35 mm thick flooring of approved shade set over 20mm thick base of cement mortar 1:6 (1 cement : 6 coarse sand) and pointing with cement sand mortar 1:3 with pigment to match the shade of stone with joint thickness up to 15 mm complete in all respectsRed sand stone (Karauli stone) same as coping
76Making khurras 450 x 450mm with average minimum thickness 50mm cement concrete 1 : 2:4 over P.V.C. Sheet 1 Mtr. x 1 Mtr. x 40micron finished with 12mm cement plaster 1 : 3 and one coat of neat cement, rounding edges and making and finishing the out let complete.
77Chequerred precast cement concrete tiles 22 mm thick in footpath & courtyard jointed with neat cement slurry mixed with pigment to match the shade of tiles including rubbing and cleaning etc. complete on 20 mm thick bed of cement mortar 1:4 (1 cement : 4 coarse sand) Ordinary cement without any pigment.
78Steel work in built up tubular trusses including cutting, hoisting ( height upto 10 m)fixing in position and applying a priming coat of approved steel primer, welded and bolted including special shaped washers etc. complete.
79Providing corrugated G.S. sheet roofing including vertical / curved surface fixed with polymer coated J or L hooks, bolts and nuts 8 mm diameter with bitumen and G.I. limpet washers or with G.I. limpet washers filled with white lead and including a coat of approved steel primer and two coats of approved paint on overlapping of sheets complete (upto any pitch in horizontal/ vertical or curved surfaces) excluding the cost of purlins, rafters and trusses and including cutting to size and shape whenever required.0.80 mm thick with zinc coating not less than 275 gm/m2
80Providing ridges or hips of width 60 cm over all width plain G.S. sheet fixed with polymer coated J or L hooks, bolts and nuts 8 mm dia. G.I. limpet and bitumen washers complete..0.80mm thick with zinc coating not less than 275
81ADD AMOUNT FOR MODULAR KITCHEN
82ADD FOR ORNAMENTAL WORK IN MASONARY,JALI AND PAINTING ETC
83Earth work in excavation by mechanical means (Hydraulic Excavator )/ manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan) including dressing of sides and ramming of bottoms, lift upto 1.5 m, including taking out the excavated soil and depositing and refilling of jhiri with watering & ramming and disposal of surplus excavated soil as directed with in a lead of 50 meter. All kinds of soils Both tank
84M10 grade Nominal Mix 1:3:6(1cement :3coarsesand:6gradedstone aggregate 20mm nominal sizBoth tanke)
85Centering and Shuttering with plywood or steel sheets including strutting, propping bracing both ways and removal of formwork for foundation , footings, strap beam, raft , bases of columns etc. floor outer
86Centering & shuttering with plywood or steel sheets including strutting, propping bracing both ways with steel props and removal of formwork for upto floor five level for :
87Suspended floors, roofs, landings, staircases, balconies, girders, cantilevers, bands, coping bed plates, anchor blocks, sills, chhajjas, lintel, beam, plinth beam etc.
88Providing and fabricating reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding (including cost of binding wire) all complete up to floor Five level. Thermo-mechanically Treated bars (Conforming of relevent IS code)
89Providing and laying in position specified grade of cement concrete for all RCC structural elements upto plinth level including curing, compaction, finishing with rendering in cement sand mortar 1:3 (1 cement: 3 coarse sand) and making good the joints and cost of plastizers( if required) excluding the cost of centering, shuttering and reinforcement. M20 grade Nominal Mix / Design Mix
90Providing M-25 grade concrete by using cement as per codal provision instead of M-20 grade design mix.
91Suplying and Fixing Ductile iron Man Hole Covers/storm water grating and gratingwith frame of various sizes weight and types and load bearing capacity as per EN -124 ,superior quality or equivalent, comlete as per Direction of Engineer In charge
92ladder ,pipe and other item etc.
93Construction of tube well from ground level and up to 100 mtr depth and above to accommodate housing assembly pipe in all type of unconsolidated formation such as pebbles, boulders, collapsible formation etc. by Odex drilling method as per IS: IS:2800 Part 1: 1991 and IS:2800 Part II: 1979 (both amended up to date) and technical specifications. The work will include lowering of housing and strainer pipe assembly and casing shoe including cost of casing shoe, but excluding cost of the casing pipe. The work would be completed after obtaining sand free water.Nominal bore 200 mm dia.
94Add 15% extra on above item (Item No 2.6.1 to 2.6.3) for drilling depth beyond 100 mtr, rate shall be applicable for only extra depth beyond 100 mtr .
95Labour charges for making slots on blank pipes made of ERW MS black pipe ISI marked of following sizes, the slotting should be as per IS:8110-1985.200 mm dia nominal bore of 5.4mm thickness
96Supply & Fixing tube well cover of MS sheet 8mm thick at top & 5mm thick 100mm wide shroud around the edge so as to form a cap on the top end of casing pipe with GI Nipple 45cm long & two GI flanges at both ends in 80mm sizes passing through a hole in the centre of MS sheet. A 25 mm socket with end plug shall also be welded over top plate. A GI nipple having outside thread of size 1/2\\" (for installation pressure gauge) shall be provided & welded with 80mm GI nipple near top plate nipple shall be provided with end plug.
97Supply & Installation of 3 phase ISI marked submersible motor pump set of three star or better rating of BEE and as per IS: 8034-2018 (pump) and IS 9283- 2013 (motor) or as amended up to date of approved make of following duty condition with required accessories including making connection suitable for tube well/DCB. The job includes lowering of motor pump, installation of complete fitting & accessories, jointing of electrical cables up to switch board, testing of submersible pump set and interconnection up to water mains, complete in all respect. 9.3 KW (12.5 HP) & head above 120 mtr.
98Supply & Fixing of ISI marked three core PVC flat submersible cable as per IS 694:1990 or amended up to date and conductor as per class 5 of IS 8130:1980 including making connection etc.3 core 4.0 Sq.mm
99Supply & Fixing XLPE insulated / P.V.C. sheathed cable of 1.1 KV grade with aluminium conductor Armoured of IS:7098-I/1554-1 approved make in ground as per IS:1255 including excavation of 30cmx75cm size trench, 25 cm thick under layer of sand, second Class bricks covering, refilling earth, compaction of earth, making necessary connection, testing etc. as required of size. 16.0 Sq.mm, 4 core
100Providing & Lowering in tube well ISI marked GI Pipe medium duty (“B\\" class), Steel tube as per IS:1239 or amended up to date and zinc coating as per IS 4736, threaded and double flanged (welded) on both ends and two number 25x3mm MS flat welded on both ends between pipe & flange, rubber washer & nut bolts etc. complete in all respect.
101Providing & laying ISI marked GI Pipe Light duty ( “A” class) as per IS: 1239 for casing pipe for submersible cable external work 40 mm dia complete in all respect.
102Providing & Fixing of double flanged, CI body, ISI marked NRV of approvedmake of following sizes
103Providing & Lowering in tube well ISI marked GI Pipe medium duty (“B\\" class), Steel tube as per IS:1239 or amended up to date and zinc coating as per IS 4736, threaded and double flanged (welded) on both ends and two number 25x3mm MS flat welded on both ends between pipe & flange, rubber washer &nut bolts etc. complete in all respect.
104Providing, installing, testing and commissioning of double flanged bulk flow meter with removable mechanism, of class B conforming to ISO 4064/1 or amended up to date of approved make including cost of all material and labour as per specifications with GI Box (sheet 16 SWG) suitable with lockingarrangement of following dia. 50 mm dia
105Supply and Fixing of electric control feeder panel comprising of suitable rating MCCB , fully automatic star-delta starter, over load relay, ampere meter with CTs, volt meter, phase preventer, suitable starting capacitors, phase indicators, lighting arrangement etc. complete suitable for three phase pump set. The panel should have space for energy meter ( supplied by DISCOM). All these equipments shall be housed by panel box made out from 18 gauge M.S. Sheet with powder coating. Panel should be of minimum size 900 x 600 x 450 mm with Stand ( made of angle iron of size 35x35x5mm) duly bolted/screwed with enclosure box having 4 legs, each leg’s length 18\\" and double door including in built locking system. The legs should be embedded in M-15 cement concrete plat form. The size of CC platform should be equal or bigger than the base size of panel having height of at least 200 mm from ground level. The panel should have opening of suitable size in front of space for energy meter with glass for meter reading. The operation of panel should be suitable for on 440 Volt AC Supply.Above 10 HP and up to 15 HP
106Plate Earthing as per IS:3043 with G.I. Earth plate of size 600mm x 600mm x 6.0mm by embodying 3 to 4 mtr. below the ground level with 20 mm dia. G.I. 'B' class watering Pipe including all accessories like nut, bolts, reducer ,nipple, wire meshed funnel, and C.C. finished chamber covered with hinged type with locking arrangement C.I. Cover, C.I. Frame of size 300mm x 300mm complete with alternate layers of salt and coke/charcoal, testing of earth resistance as required.
107Providing & Fixing pump safety cage as per specifications or as directed byEngineer in charge.
108Supplying & Installing 100 mm diameter sealed diaphragm bourdon type pressure gauge of range 0 to 10 kg. including all jointing material as perspecification with safety cover.
109Supply of ERW M.S. black casing pipe ISI marked (IS: 4270/2001) or amended up to date of following sizes200 mm dia NB (Thickness of pipe 5.4mm & mass of tube 28.46 Kg/m)
110Add for electric connections ls
111Earth work in excavation by mechanical means (Hydraulic Excavator )/ manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan) including dressing of sides and ramming of bottoms, lift upto 1.5 m, including taking out the excavated soil and depositing and refilling of jhiri with watering & ramming and disposal of surplus excavated soil as directed with in a lead of 50 meter. All kinds of soils
112Providing and laying in position cement concrete including curing, compaction etc. complete in specified grade excluding the cost of centering and shuttering - All work up to plinth level. 1:4:8 (1 cement : 4 coarse sand : 8 graded stone aggregate 40 mm nominal size).
113Brick work with mechanised autoclaved flyash lime bricks conforming to IS: 12894 :2002 of class designation 100 in superstructure above plinth level upto floor V level in.Cement mortar 1 : 6 (1 cement : 6 coarse sand)
114Plaster on new surface on walls in cement sand mortar 1:4 including racking of joint etc. complete fine finish :20mm thick.
115Random rubble dry stone Kharanja under floor
116Cement concrete flooring 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate) finished with a floating coat of neat cement including cement slurry, making of lines or groove etc complete but excluding the cost of nosing of steps etc. complete. 75mm thick with 20mm thick nominal size aggregate.
117Stone Aggregate filling (Single size) : 63 mm nominal size
118Stone Aggregate filling (Single size) : 12.5 mm nominal size
119Bajri filling
120Providing and fixing of Reinforced Ferro cement Drain cover designed for class \\"B\\" loading duly marked on cover with adequate steel reinforcement having thickness 50 mm to 75 mm anti- corrosive bitumen painted M.S. plate Rim and on M.S. lifting hooks admixture like plasticizer bond improving compound shrinkage resistance compound abrasion resistant complete as per approved design etc. for drain Opeining Size 1201 to 1500 mm Standard Drain Cover Size 1800mm x 600mm x 75mm
121Construction of tube well from ground level and up to 100 mtr depth and above to accommodate housing assembly pipe in all type of unconsolidated formation such as pebbles, boulders, collapsible formation etc. by Odex drilling method as per IS: IS:2800 Part 1: 1991 and IS:2800 Part II: 1979 (both amended up to date) and technical specifications. The work will include lowering of housing and strainer pipe assembly and casing shoe including cost of casing shoe, but excluding cost of the casing pipe. The work would be completed after obtaining sand free water.
122Supply of ERW M.S. black casing pipe ISI marked (IS: 4270/2001) or amended up to date of following sizes 200 mm dia NB (Thickness of pipe 5.4mm & mass of tube 28.46 Kg/m)
123Wiring of light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible class 2 copper conductor 1.1 kV grade and 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible class 2 copper earth conductor 1.1 kV grade (IS:694) in recessed ISI marked MMS ( IS:9537 P - III ) PVC conduit & it's ISI marked (IS:3419-1988) accessories, Aluminum round tiles, 1.2 mm thick Hot Dipped Galvanized Modular Box with earth terminal, 6 A Modular switch, Modular face plate with grid plate, 3 pin ceiling rose / Holder /3 way connector, screws, making connections, testing etc. as required.Short point (up to 3 mtr.)
124Medium point (up to 6 mtr.)
125Long point (up to 10 mtr.)
126Wiring of twin control light point with 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible class 2 copper conductor 1.1 kV grade and 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible class 2 copper earth conductor 1.1 kV grade (IS:694) in recessed ISI marked MMS ( IS:9537 P - III PVC conduit & it's ISI marked (IS:3419-1988) accessories, Aluminium round tiles, 2 Nos Hot Dipped Galvanized M.S Modular box of 1.2 mm thick with earth terminal,2 Nos 6 A two way Modular switch, 3 pin ceiling rose / holder / 3 way connector ,Modular face plate with grid plate, screws, making connections, testing etc. as required.Short point (up to 3 mtr.)
127Medium point (up to 6 mtr.)
128Long point (up to 10 mtr.)
129Wiring of 3/5 pin 6 amp. Light plug point with 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible class 2 copper conductor 1.1 kV grade and1.5 sq. mm nominal size FR PVC insulated unsheathed flexible class 2 copper earth conductor 1.1 kV grade(IS:694) in recessed ISI marked MMS ( IS:9537 P- III ) PVC conduit & it's ISI marked (IS:3419-1988)accessories, Hot Dipped Galvanized Modular box of 1.2 mm thick with earth terminal, 6 A modular switch, 3/5 pin 6 A modular socket, Modular face plate with grid plate, screws, making connections, testing etc. as required.On board
130Short point (up to 3 mtr.)
131Medium point (up to 6 mtr.)
132Long point (up to 10 mtr..)
133S&F following sizes (dia.) of ISI marked MMS ( IS:9537 P - III ) PVC conduit along with ISI marked (IS:3419-1988) accessories as required in recess including making jhiri in the wall,clamps at suitable spacing, covering conduitand making good the same as required.20 mm
13425 mm
13532 mm
13640 mm
137Supplying and laying FR PVC insulated & unsheathed flexible copper conductor of following nominal sizes with ISI marked (IS:694) and as per IS 8130 : 2013 of1.1 kV grade . Wire should be made from copper, stranding in acc. to IS:8130/IEC 60228 for lower watt loss , oxygen free for less chances of oxidization, insulation PVC type A/C/D , flame retardant as per IS 10810-53, better amperage rating as per IS:3961 part 5, in existing surface or recessed PVC/ MS conduit/casing capping making connections with Copper Lugs of suitable size, Ferrules,testing etc. as required.1 x 1.5 sq.mm ( for Invertor )
1383x 1.5 sq.mm
1392 x 2.5 sq. mm. + 1x1.5sqmm
1401 x 4.0 sq.mm ( For Earthing LDB/PDB)
1412 x 4.0 sq. mm. + 1 x 2.5 sq. mm.
1424 x 6.0 sq.mm ( For LDB)
1432 x 6.0 sq. mm. + 1 x 2.5 sq. mm.
1444 x 10.0 sq.mm ( For PDB)
145Supplying and Laying PE Insulated & PVC Sheathed unarmoured telephone cable with 0.5 mm dia. Solid Annealed electrolytic grade bare Copper Conductor as per IS: 8130/84 & confirming to TEC specification GR / WIR/06-03 March 2002 in existing surface or recessed conduit/casing capping. including ferruling on each pair for Identification etc. as required . 2 pair
1465 pair
14720 pair
14850 pair
149Supplying and Laying coaxial cable 75 ohm impedance with foam PE insulated solid bare copper inner conductor, and Ist outer conductor of bonded alum. tape and second outer conductor of alum. alloy braid in existing surface or recessed conduit/casing capping including making connections as required.
150Supply and laying speaker cable of following size 2 core twin twisted multi stranded electrolytic grade copper conductor, overall PVC insulated and armoured cable (Blue colour) on surface/ above false ceiling including cost of GIspacers, saddles etc. as required.
151Supplying and fixing of power plug point with Modular accessories on hot dipped galvanized modular box of 1.2 mm thick with earthing terminal/connector on surface or in recessed with suitable size of modular face place with grid plate and cover plate including cost of ISI marked modular 16 amp. Switch (IS :3854) and 6/16 amp. socket outlet (IS:1293) making connection , testing , etc. as required.
152P & F 1.2 mm thick M.S. Recessed fan box and top lid screwed on Box, hexagonal/ round of size 130 mm dia, depth 75mm, 12 mm dia rod fan hook with 150 mm length extended on each side as required.
153P & F paper phenolic resin bonded laminates confirming to IS : 2036 - 1995 for boxes/ frames including making holes for switches etc, with brass screws,washers/ zinc plated nut and bolts as required.3.0 mm thick
154Supply, Drawing and Testing of 4 pair, 23 AWG Solid Bare Copper wire insulated with PVC, U/UTP (Unscreened/Unshielded Twisted Pair), Category 6, Class E, 100 Ohm Impedance, Indoor Cable as per latest ammendments of ANSI/TIA/EIA-568 , The copper conductors should be balanced twisted in pairs, seperated by a cross-member fluted pair divider & protected by LSZH Jacket. Certified performance in a 4-connector configuration upto 100 Mtrs channel requirements & transmission frequencies ranging from 250 to 500 Mhz. in existing MS/PVC Conduits/casing capping including making connections to Information outlets and Patch Panels with jack & ferruling at both ends for identification with necessary tools for punching, stripping, crimping and testing etc as required complete in all respect.
155Supply and Installation of unshielded/360 degree shielded PCB based Information outlets made of high impact plastic body with ABS, Flammability rating UL 94 V-0 with provision for protection against dust in jack or Faceplate, suitable for Cat 6/6A application complying to latest amendments, According. to Cat. 6/6A channel, It should support channel as well as components requirements of Cat 6/6A standards at frequencies 250/ 500 MHz. Cat 6/6A unshielded/shielded Jack should be suitable to terminate 4 pair, 23/24 AWG solid/stranded wire diameters, using 100 Ohm unshielded/shielded balance twisted pair cable, the jack should have toolless/impact termination on reliable copper tin plated Insulation displacement contact, with easy lock mechanism, It supports IEC 60603-7-4 and complied with ANSI/TIA 568 C.2 & ISO/IEC 11801 or latest standard. jack should be RJ11,RJ12 & RJ45 compatible. Should support Ethernet 1.2 Gb/s ATM,Digital video and broadband/baseband analog video, Voice over internet protocol (VOIP) Specifications in existing modular/MS Boxes along with necessary connections as required. All as per pre approved by Engineer in charge.Cat 6, Un-sheilded Information Outlet
156Supply & fixing of square Faceplate for Flush / Surface Mount Information Outlets Single/Dual or Quad Aperture with dust cover, material should be High- impact, flame retardant, thermoplastic, UL listed material, Suitable for RJ45 unshielded/shielded connection modules. Should match with I. O. OEM. Dimensions should be 86mm X 86mm as required complete in all respect. All as per pre approved by Engineer in charge.
157Supply, Installation, Testing and Commissioning of Rack mounted 19\\" 1U, 24 Port loaded, CRS chasis, powder coated, sheet steel, High-impact, flame retardant, thermoplastic, UL Listed, Modular Patch Panels with Rear Cable management system and mounting hardware to mount the patch panel. Should have port identification numbers printed/engraved on front of the panel. Etc. as required. All as per pre approved by Engineer in charge.Modular Patch Panel Loaded with Cat -6 I/O
158Supply , Installation and Testing of 4 pair, 100 Ohm impedance, Cat 6/6A /Class E/Ea patch cords should be constructed of minimum 23/24 AWG, stranded bare Copper cable with LSZH Jacket, with an enhanced performance by factory moulded RJ45 connectors with strain relief boots as per ANSI/TIA/EIA 568-C.2 suitable for Cat 6/6A application complying to latest ammendments Category 6/6A Standards, According. to TIA568C.2, ISO/IEC 11801, EN 50173, IEC 60603-7-51, EN 60603-7, IEEE 802.3an minimum requirement for 1G BASE-T to 10G BASE-T performance. Patch cords shall be straight thru cable compatible with both T568-A and T568-B wiring schemes, should support IEEE 802.3af / IEEE 802.3at for POE applications, Minimum 750 to 1000 mating cycles in plug contacts for long durability, Should support Ethernet 10GBASE-T, 1.2 Gb/s ATM, Token ring 4/16, Digital video and broadband/baseband analog video, Voice over internet protocal (VOIP).Cat 6, U/UTP (Unscreened/Un-sheilded Twisted Pair) Patch Cord1 Mtr
159Supply & Installation of IP-20 & IK-08 , Wall mounted Double Section Communication enclosure (Rack) made from powder coated (60 to 80 Micron) CRCA sheet, front sturdy sheet steel frame folded from one piece and welded with minimum 5mm toughened glass door,Vertical Mounting Rail 1.6 MM with 'U'Marking , with All round protective channel on the door aperture, lock integrated on front door, top and bottom cover with cable entry provision with gland plates, integrated side walls, 2 pair of 19\\" angles with wall mounting provision on wall. Accessories like: 1 No of 19\\" 1U Horizontal Cable manager, 1 No of 90 cfm 230V AC Fan with 1 mts long cable, mounting hardware , 1 No of 19\\" 1U, mountable socket strips with 5 nos of 5A universal sockets with 2 mts long power chord for supplying power to switches, fans etc along with earth continuity kit, indicator, moulded power supply cable. fixing on wall with Suitable Anchor fastner etc as required.9 U Rack with Width 600 mm & Depth 400 mm + 100 mm
160Supply , Installation, Testing and Comissioning of Unmanaged Switch Plug-and- play - easy setup with no configuration or no software needed, following Port fast ethernet - 8 port 10/100/1000 MBPS auto-negotiation RJ45 ports, IEEE 802.3x flow control ,supports auto-MDI/MDIX, eliminating the need for crossover cables including making connection etc as required complete in all respect.
161SITC of IP Based 5MP Bullet camera: 1/2.8\\" or larger Progressive Scan CMOS Sensor with resolution:(2560 x 1920) @30 fps Should Support H.264, H.265, MJPEG, Quad/Triple streaming profiles, Frame rate upto 1-30 fps, 120dB WDR, 2DNR/3DNR, BLC. Camera should support Open standard to support ONVIF (PROFILE S, PROFILE G, PROFILE T), 1/1 Audio In/Out or better and 1/1 Alarm In/Out or better, onboard storage upto 512GB (SD card not included). The camera supports advanced Video Analytics (VA) including motion detection and alarm should be trigger on Tampering, Network disconnect, IP address conflict. CCTV should have password protection, privacy mask, IP address filtering, Metal Housing, Vandal-proof housing, IP67, IK10, DC 12V & PoE, Complete with Junction box for cable management. Operating Conditions within -20°C to 60°C or better. The MAC address of Camera/NVR must be registered in the name of OEM. Regulatory approvals include FCC, BIS/UL, CE. CCTV cameras must be BIS Registered Cyber Security Certified by STQC as per IoTSCS and meet the Essential Requirement (ER) issued by MeitY for security. The CCTV OEM should have its service/ support center in Rajasthan.2.8/3.6/4/6/8 mm lens IR Range - 50mtr or higher,
162SITC of IP Based 5MP Dome camera: 1/2.8\\" or larger Progressive Scan CMOS Sensor with resolution:(2560 x 1920) @30 fps. Should Support H.264, H.265, MJPEG, Quad/Triple streaming profiles, Frame rate upto 1-30 fps, 120dB WDR, 2DNR/3DNR, BLC. Camera should support Open standard to support ONVIF (PROFILE S, PROFILE G, PROFILE T), 1/1 Audio In/Out or better and 1/1 Alarm In/Out or better, onboard storage upto 512GB (SD card not included). The camera supports advanced Video Analytics (VA) including motion detection, and alarm should be trigger on Tampering, Network disconnect, IP address conflict. CCTV should have password protection, privacy mask, IP address filtering, Metal Housing, Vandal-proof housing, IP67, IK10, DC 12V & PoE, Complete with Junction box for cable management. Operating Conditions within 20°C to 60°C or better. The MAC address of Camera/NVR must be registered in the name of OEM. Regulatory approvals include FCC, BIS/UL, CE. CCTV cameras must be BIS Registered Cyber Security Certified by STQC as per IoTSCS and meet the Essential Requirement (ER) issued by MeitY for security. The CCTV OEM should have its service/ support center in Rajasthan.6/8 mm Lens more than 30 to 50 meter or above IR range
163SITC of 32CH NVR for 2/5 MP cameras with minimum 4 SATA HDD Support with minimum 40 TB Capacity (minimum 10TB Capacity per slot - Hard Disk Not Included), minimum 1 HDMI output port, Video comression - H.265/H.264/JPEG, 1/1 Audio In/Out, Preview Capability - Upto 4K, Playback: 16-channel simultaneously. NVR should support minimum 320 Mbps throughput bandwidth (160 incoming bandwidth), ONVIF compliance (Profile S/G/T). Recording resolution up to 4K/8MP, minimum 2 USB Ports, minimum 1 Ethernet Ports (RJ-45) 10/100/1000Mbps. RAID 0/1/5/10 or better. The system shall operate in 0°C to +50°C or better with BIS, FCC, CE. The CCTV OEM should have its service/ support center in Rajasthan.
164SITC of 3.5\\" 4TB internal HDD for cctv recording ,capable for 24x7 operation, hdd rpm capacity shoud be 7200 rpm or better, Buffer should be 512 MB asrequired of following size.
165SITC of IP-PBX which is IP at its core and act as a Unified Communication System with IP switching technology and 100% non-blocking, configured for below mentioned. The system should be IPV6 ready, should have VoIP and Voice mail at its core i.e. these modules should be mountable on the CPU. The system should be Q Sig Ready, inbuilt Auto-attendant facility, Returned Call to Original Caller (RCOC), CLI based DISA (Mobile Extension)System, Should support SNMP manager for managing and monitor network elements, audit network usage and detect network faults, should support SIP over TLS and SRTP, minimum 2 Gigabit Ethernet ports for LAN and WAN, built-in multi- party conferencing facility with 21 party in a single conference, minimum one RS232 ports for SMDR/PMS/CAS Interface. The System have have capability to also act like Universal Media Gateway when required. The System should have facility of Conversation recording on Analog/Digital/IP ports as well as on Mobile SIP Smartphones, UC Client application for Android, iPhone and on Windows PC. Power supply should be inbuilt and SMPS type with input ranges from 100 – 240 V AC, 47-60 Hz OR 48VDC +/- 15%. The system must have Certification: TEC, CE, FCC, ROHS.48 analogue extensions, 04 PSTN Trunk Port, 12 Channel SIP PRI, 04 Digital Port, 15 IP User License, 5 IP Softphone/mobile user license, 08 VoIP Channel License along with 8 port Voice Mail expandable upto minimum 224 TDM ports and minimum 500 SIP/IP users without any add-on CPU or chassis/hardwareplatform.
166SITC of Line Card for required Analog / Digital / CO Extensions. compatible tothe IP PBX as required.8 Digital Extensions
167SITC of Digital Phone/Operator Console with 240 x 64 or better– Pixel Graphical LCD with Backlit, LED for Incoming/Ongoing Call, Mute, Call Hold, Do Not Disturb, Speed Dial, Hotline, Redial, Call Back, Auto Answer, Call Forward, Call Waiting, Call Transfer, Room Monitoring, Conference, Directory, Call Logs ,Dial-by-Name, Message wait Lamp, Ringer Lamp. Voice Mail ,Call Pickup – Group and Selective, backlight display panel, minimum 16 memory/speed dial keys can be extended upto 128 keys with support of Add on key module, 4 Context Sensitive Hard Keys, Multiple Languages, Caller ID with Name & Number, RJ9 Handset Port, 3.5 mm Headset Port, Certifications - TEC, CE, FCC, RoHS.
168SITC of Type-I IP Phone with 128 x 64 or better –pixel Graphical LCD , Extended SIP Protocol, LED for Call and message wait Indication, 3 Feature Keys:Headset, Mute, Hands-free speaker phone, 4 Context Sensitive Keys, 2 Line keys with Function such as navigation, Call Appearance , feature status, Volume Control Keys, 2 X RJ45 10/100/1000 Mbps Ethernet Ports, Power Over Ethernet (IEEE 802.3af), minimum one RJ9 Handset port, one RJ9 Headset port & Power Supply - 5VDC 0.6A, Power consumption - 1Watt, 0°C to 45°C or better, Certifications: TEC, CE, FCC, RoHS.
169Providing & Fixing of 240/415 V AC MCB with positive isolation of 10 kA breaking capacity (B/ C/D tripping characteristic as per type of load and site requirement) 4 KV impulse withstand voltage, ISI marked IS 8828(1996) / conforming to IEC 60898-1 2002, IEC 60947-2, low watt losses, trip free mechanism , energy limiting of class 3 as per IEC, minimum phase termination capacity of 25 sq.mm., conductor line load reversibility , IP 20 contact protection and fitted in existing distribution board/sheets, minimum electrical operation 20,000 upto 20 A rating, 10,000 upto 63 A, 5000 for 80 A & above rating including making connections, testing etc. as required. Single pole MCB (With B / C curve tripping characteristics)
170Double pole MCB (With B / C curve tripping characteristics)
171Triple pole MCB (With B / C curve tripping characteristics)
172Four pole MCB (With B / C curve tripping characteristics)40 A rating
17350/63 A rating
174Providing & Fixing of 240/415 V factory fitted RCBO with overload, short- circuit and earth leakage protection with ISI marked (IS12640-2)/ conforming to IEC 61009-1, breaking capacity 10 KA, provision for pad lock, min. Electrical operation 10,000 upto 63 A rating , minimum phase termination capacity of 25 sq.mm. , IP 20 contact protection with existing distribution board / sheet including making connections, testing etc. as required.Two pole 30 mA sensitivity40 A rating
175Providing & Fixing of Recessed/surface mounting heavy duty horizontal type Double Door (Metal / Glazed / Acrylic) Distribution board with Metal end box made out from Galvanized steel / CRCA sheet, powder coated conforming to IS- 8623-1 & 3 / IEC 61439- 1 & 3, complete with 100 amp. insulated copper bus bar/shorting link , brass neutral link with shrouds, brass earth link , door earthing arrangement, color coded interconnecting wire set of minimum 10.0 sqmm size and din bar,masking sheet, making internal DB terminations with copper lugs, Ferrules, detachable gland plate, including making connections, testing etc. as required.Metal door (single phase) IK-09 and IP-43 with Metal end box
176Metal door (Three phase) IK-09 and IP-43 with Metal end box6 Way (8 incomer + 18 Outgoing)
1778 Way (8 incomer + 24 Outgoing)
178P&F metal clad / Polyamide industrial plug top & socket unit with pin and sleeve type contact on porcelain/ bakelite base in Recessed/surface mounting heavy duty Enclosure made out from Galvanized steel / CRCA sheet , powder coated conforming to IS-8623-1 & 3 / IEC 61439- 1 & 3. (without MCB) includingmaking connections, testing etc.as required.20 amp, (2P + E), 1 Module
179Providing & Fixing of Recessed/surface mounting heavy duty Vertical TPN Distribution board with Metal end box with provision of incomer suitable for 3/4 pole MCCB and SP / TP MCB up to 63 Amps. as outgoing ,made out from Galvanized steel / CRCA sheet , powder coated conforming to IS-8623-1 & 3 / IEC 61439- 1 & 3. complete with insulated 125/160/200/250 Amp. copper bus bar, brass neutral bars with shrouds, brass earth bar , color coded interconnecting wire set of suitable rating and din bar, door earthing arrangement, masking sheet, making internal DB terminations with copper lugs, ferrules, detachable gland plate, including making connections, testing etc. as required. Double door IP-43 & IK-09 with Provision of Incomer MCCB up to 125 ARating with Metal end box6 Way
180Providing & Fixing of ISI marked (IS:371) 6 amp surface type 3 pin ceiling rose with CM/L no. printed and made out from industrial grade Polycarbonate material, brass terminal & captive screws including making connection testing etc. as required.
181Providing & Fixing of ISI marked (IS:1258) batten/angle lamp holder with CM/L no. printed and made out from industrial grade Polycarbonate material, brass terminal & captive screws including making connection testing etc. asrequired.
182Providing & Fixing of ISI marked (IS:1293) 16 amp unbreakable 3 pin plug top having lamp indicator with CM/L no. printed and made out from industrial grade Polycarbonate material, brass terminal including making connection testing etc.as required.
183Providing & Fixing of single / multi tone electronic call bell / remote bellincluding making connection testing etc. as required.
184Providing & Fixing of ISI marked (IS:302) ding dong/musical chime bellincluding making connection testing etc. as required.
185Providing & Fixing of modular type switch/ bell push duly ISI marked (IS :3854) with CM/L no. printed and made out of unbreakable and fire retardant virgin UV Stabilized Polycarbonate with brass terminals and captive screws & silver alloy contact tip with IP-20 rating ,minimum width of switch toggle( PUSH PART ) should not less then 20mm, including making connections, testing etc as required.6 A bell push
18610 A one way switch
18716 A one way switch 1M
18816 Amp. 2 Module switch With Led Indicator
18932 Amp. 2 Module switch With Led Indicator
190Providing & Fixing of IS:1293 marked modular type lockable feature socket with CM/L no. printed duly made out of unbreakable and fire retardant virgin poly carbonate with brass terminals and captive screws & silver alloy contact tip with IP-20 rating, including making connections, testing etc as required.6 A 3 pin shuttered socket
1916/16 A shuttered socket
19213 A flat pin international socket (Non ISI)
193Providing & Fixing of modular type 100W Step Fan regulator duly ISI marked (IS 11037) with CM/L no. printed made out of unbreakable and fire retardant virgin poly carbonate with brass terminals and captive screws & silver alloy contact tip with IP-20 rating , including making connections, testing etc as required.5 step fan regulator 2 Module
194Providing & Fixing of 3 M Key card switch with Load capacity 20 amp, Off time delay 30 Sec. made out of unbreakable and fire retardant virgin poly carbonate,including making connections, testing etc as required.
195Providing & Fixing of following modular accessories, made out of unbreakable and fire retardant virgin poly carbonate with brass terminals and captive screws & silver alloy contact tip with IP-20 rating, including making connections, testingetc as required.RJ-11 telephone jack single line
196RJ-11 telephone jack Double line
197USB Charger 2 A - 1 M with BIS mark
198RJ-45, Cat 6 computer jack with shutter
199T.V. coaxial socket
200Blanking plate
201LED Skirting /Foot Light 2 Module
202Electronic Chime/Buzzer 2M
203Modular MCB 6 A to 32 A DP
204Providing & Fixing of following size mounting grid plates with cover plates made from fire retardent UV established high performance engineering plastic suitable for all universal metal boxes for front installation & removal direct fit1/2 Moduletype complete in all respect.
2053 Module
2064 Module
2075 Module
2086 Module
209Providing & Fixing of following size cover plates made from fire retardent UV established high performance engineering plastic suitable for all universal metal boxes for front installation & removal direct fit type complete in all respect.1/2 Module
2103 Module
2114 Module
2125 Module
2136 Module
214P & F Krone module with base frame in the recess / surface made out of 1.2 mm thick sheet steel box, front openable, having locking arrangements duly powder coated ,including dressing, ferruling and punching of telephone cable withkrone tool etc. as required.20 Pairs
21550 Pairs
216SITC of IP-42 and general construction confirming to IS:8623 : 1993, wall/ free standing floor mounted dust and vermin proof compartmentalised cubical panel as specifications and Other parameters required as per point (a) ,(b), (c),(d), (e), (f), (g), (h) as below:-(a) Thickness of CRCA sheet shall not be less than 1.6 mm upto 450 mm length/ width of any compartment and be 2.0 mm above 450 mm, load bearing structure shall be 2.0 mm thick sheet supported by base M.S. channel if required, cable alley compartments having concealed hinged type doors with key type lock with / without detachable extension type structure. Removable 3 mm. thick sheet steel gland plates with appropriate size of knockouts for cables shall be provided(b) complete panel shall undergo a process of degreasing, Water rinsing, Activation, derusting, pickling in acid bath, phosphatising & shall be subjected to nine tank process and then Powder coated with approved shade of minimum 70 microns on both side(Inner & Outer side) of panel. The panel having PE foam/ Neoprene rubber gasket of not less than 3mm thickness ,required hardware, concealed hinged door with key type locking arrangement for equipment/switchgear earthed with 2.5 sq.mm braided copper wire.[c) Interconnection between bus bar and switchgears /cable shall be rigidly supported and made out by flexible copper wires (up to 63 amp ) and by solid bus bar (>63 amp ) . control wiring will be carried out with 1.5 Sq.mm, Earth wire with 2.5 Sq.mm and CT with 2.5 sq.mm flexible copper wire only. All joints / interconnections of copper bus bar shall be dully tinned . Clearance between main bus bar and risers / metal parts shall be at least 10 mm additional to width of bus bar Bus bar is insulated by Heat Shrinkable sleeves . Earth and Neutral bus bar shall be half of the size of phase bus bar. ( Cost of Bus bar / Flexible wire for Interconnection between Main busbar and Switchgear is to be Paid Extra )d) Wiring between components within switchgear and Incoming / outgoing cable shall be done through the terminal block only. Direct connection shall not be permitted. Each terminal block shall be one piece moulded, barrier type, 650 volt grade, complete with washers, heads, studs with two nuts and identification strips and shall have adequate continuous current rating. For tap-offs, adjacent terminals with shorting strips shall be used. 10% Spare terminal blocks shall be provided. Wire identification on marking strip shall correspond to the designation of the wiring diagrams. All wire terminals on the equipment shall also be marked with designation corresponding to those of the wiring diagram.(e) All wiring shall be enclosed in plastic channels and neatly bunched and closed in metering chamber, Wiring between terminals of various devices shall be ‘point to point’ (no wire splitting or tee connections) with wires neatly trucked along the back of the panels, adequately supported to prevent sagging.(f) Floor mounted panel shall be mounted on Base frame of ISMC channel size100 x 50 x 5 mm ( to be paid Extra )(g) Tests: The insulation resistance (with 1000 V Megger) and High voltage Power frequency test (by applying a voltage of 2.5KV for one minute) shall be measured between phases, between phase and neutral and between phase and earth. both before and after high voltage power frequency test. The insulation resistance shall not be less than three megaohm. CT Secondary current injection(h) only outer surface area on all sides shall be measured & panel to be fabricated only from CPRI approved fabricator only (CPRI type Test certificates for Temp. rise test, Short circuit test for 50 kA and IP test is to be submitted)test shall also be carried out.
217Supplying and fixing of Aluminium (IEC 60105 ISO 209-1,2) / Copper (IEC 60028) bus bar by means of SMC / DMC type insulator, with short circuit withstand capacity of 31 MVA for 1 Sec. , high tensile nuts and bolts spring washers in existing panel including bending , cutting in required shape and size and colour coding with heat shrinkable PVC sleeves.Electrolytic grade Aluminium bus bar 6010 grade
218Providing & Fixing of IS: 13875 & IEC :61326/IEC:62053-22 confirming LED Digital type (up to 500) V range Volt meter / Direct- Ammeter / CT opertated ammeter/ Frequency meter / KWH meter / Multi Function Meter / Power analyzer of class 1 accuracy of size 96mm x 96 mm including making connection by PVC insulated copper conductor with PVC sleeves / channel etc. as required.Three phaseAMP+HZ+PF+KW+KVA+KVAR+T.ENERGY+THD-I, THD-V& RUN HRS Meter
219Providing & Fixing of Current Transformer confirming IS 2705-I (1992) with secondary terminal and shorting Block , with all necessary support in existing panel including connection etc. as required Current transformer Ring Type Tape Wound/Resin Cast Wound Accuracy Cl, CT ratio and burden as specified. ISF<=5, Cu cross section of secondary wire 1.5sqmm (minimum), including all necessary support in existing panel including connection etc. as required .Ring type tape wound CTC T Class 1, Ratio 800/5 to 1200/5, Burden 15 VA
220Providing & Fixing of 110/220 V, unibody LED Indicating lamp IEC 60947 with integral circuit, IP 65 above panel & IP 20 terminal block, Approx. body dia for panel not less then 20 mm, length min. 50mm, front LED cover dia min. 27 mm, contact material phospher bronze for Led, PCB contacts shall be of brass (tin plated), impulse dielectric tested for 2.5 KV, Rated insulation resistance shall be 100 M ohm at 500VDC including connection etc. as required.Red/yellow/Green colour
221Blue / white Colour
222Providing & Fixing of Electrical insulating rubber matts confirming to IS:15652 / 2006 with one side anti skid aberration marks and pasting the mat with synthetic rubber adhesive as required.3.3 KV, class A 2 mm thick with proof voltage 10 KV AC (rms) and BreakDown Voltage 30 KV AC (rms)
223Providing & Fixing of self healing IP20 MPP type shunt capacitor (banks) conforming to IS:13340-41 / IEC :831-1&2 OR IEC : 60831-1& 2 in existing panel or parallel with load terminals , the capacitor shall be fitted with discharge resistors, pressure sensitive disconnector ( PSD ) and shall have dissipation factor less than 0.0025 at 50 Hz, Operating loss less than 0.30 Watt per KVAR. Min over current capacity 1.8 times rated current & peak inrush current min. 300 times of rated current, life expectancy greater than 100000hrs (temp class - 25 D) in 440 V including making connections, testing etc. as required.Heavy duty Three phase 440 V, 50 Hz cylindrical type capacitor (Bank)
224Providing & Fixing of 440 Volt 3 pole capacitor (AC 6 B ) duty contactor with 3 no. early make and post break auxiliary contacts in series with quick discharge damping resistors/ reactors to limit the inrush current as per IS/IEC 60947-4-1 : 2000, insulation voltage 1000V, impulse withstand voltage 8 KV,Din rail mounting type including making connections, testing etc. as required. suitable for following capacity capacitor bank.10 KVAR
22512.5 KVAR
22615.0 KVAR
22720.0 KVAR
22825.0 KVAR
229Providing & Fixing of Electromechanical / digital time switch having following day / week programme and minimum 100 hours reserve and AC1 rating of 16-20 amperes including making connection, programming conforming to IEC 60730-1and 60730-2-7 etc. as required.One day reserve (Electromechanical type )
230SITC of 3 /4 pole current limiting Moulded case circuit breaker (MCCB) made of flame retardent & heat resistant material having following current rating, short circuit breaking capacity at 440/415 V, 50 Hz; O/L & S/C settings , conforming to IS/IEC 60947 P -2 :2003 with front face and centralised adjustable, trip free mechanisum, true contact position indicator, designed for both horizontal & vertical mounting without any adverse effect on electrical performance, suitable for operation from 50 to 55 degree and without derating upto 40 degree, pollution degree 3, having positive isolation capability, push (test) to trip, trip time less then 10 ms under s/c condition, Breaking capacity Ics = 100% Icu. U imp =8 KV, rated insulation voltage 690V. provision for UVR , shunt trip , earth fault trip, door interlock, pad lock & rotary handle ( to be paid extra) , including making connections etc. as required. OEM shall have submit NABL / CPRI / ERDA/ Intertek accrediated lab type test certificate.3 pole MCCB With Thermal Magnetic releaseup to 100 Amp , 10 kA, fixed O/L & fixed S/C setting
2314 pole MCCB With Thermal Magnetic release125 Amp , 25 kA, adjustable O/L & Fixed S/C setting,
232160 Amp , 25 kA, adjustable O/L & Fixed S/C setting,
233250 Amp , 25 kA, adjustable O/L & adjustable S/C setting,
234400 Amp , 35 kA, adjustable O/L & adjustable S/C setting,
235Supply and fixing of following accessories for Moulded case circuit breaker (MCCB) compatible to main MCCB OEM as per PWD specification for electrical Works, conforming to IS/IEC 60947 P - 2 :2003 including makingconnection etc complete in all respect.Extended Rotary Handle
236Spreaders upto 125A, 3 Pole MCCB
237Spreaders for 250A, 4 Pole MCCB
238Spreaders for 400A, 4Pole MCCB
239Providing & Fixing of on load change over switch, front handle operated, four pole 415 V confirming to IS/lEC 60947-3 : 1999 including connections , testingetc. as required .in the following rating.Open execution type400 A
240Providing & Laying XLPE insulated & P.V.C. sheathed Armoured Aluminium cable confirming to IS :7098 P - I of 1.1 KV with H4- Grade electrolytic aluminium conductor confirming to IS 8130 of purity >99.6 %, round / flat strip armouring of cables, Inner / outer sheath confirming to IS:5831 in existing RCC/ Hume / Stoneware / PVC pipe/ open duct/cable trench / Cable tray(with cable tie) including testing commissioning etc. as required of following size.6.0 Sq. mm4 core
24116.0 Sq. mm4 core
24270.0 Sq. mm3.5 core
243185.0 Sq. mm3.5 core
244Excavation of trench of size 75 cm (Depth) x 35 cm(Width) for laying of suitable no. of LT cables (Inter spacing between cables should not be less than 2 D) in ground with following procedure :- (a) Make a river sand bed of height 100 mm along the trench, (b) Lay the cable in the middle of the trench, (c) Provide river sand bed of height 100 mm on top of the cable, (d) Lay the protective Common burnt clay F.P.S. Bricks of Class designation 75 / Sand stone slabs of 50 mm thickness and 225 mm wide just above the sand bed vertically across the cable,(e) Backfill the excavated soil leaving 300 mm from the Ground level, (f)Lay the Cable warning tape and again back-fill the remaining portion of the trench upto the ground level and compacting the earth.
245Supplying and making end termination with heavy aluminium lugs ( Pin / ring type ) confirming to IS 8309 -1993 duly crimped with crimping tool, PVC tapeetc of following size.6.0 Sq.mm
24616.0 Sq.mm
24770.0 Sq.mm
248185.0 Sq.mm
249Supply, Fabricating & installing following sizes of perforated Hot dipped Galvanized iron cable tray ( Galvanized thickness not less then 50 microns) with perforation not more then 17.5% in convenient section including horizontal and vertical bends, reducers tees,cross members and other accessories as required and duly suspended from the ceiling with GI suspenders including GI bolts & nuts , fastners, supports etc. as required.225mm x 50mm x 1.6mm
250S/F cable route marker with 10cm x 10cm x 5mm thick or 10 cm dia. G.I.plate with inscription thereon, bolted/welded to 35mm x 35mm x 5mm angle iron, 60cm long and fixing the same in ground in C C ( 1:3:6 ) as required
251P / L of Double wall corrugated HDPE pipe confirming to IS : 16205 P-24, Stiffness Class 750 N, Externally corrugated and having smooth surface inside with HDPE Coupler, Elbow, Tee at required Depth below the ground for laying cable of following Nominal Outer dia. MFR Test report from NABL accrediated is to be submitted.(Excavation of trench, CC Haunching, Back filling of Earth with compaction is to be Paid Extra).
252Plate Earthing as per IS:3043 with copper Earth plate of purity >95% of size 600mm x 600mm x 3.0mm by embodying 3 mtr. below the ground level with 20 mm dia. G.I. 'B' class watering Pipe ,including all accessories like nut, bolts, reducer, nipple, wire meshed funnel, Heavy duty weather proof poly-propylene earth inspection chamber as per requirement of IS/IEC 62305 and tested as per IEC 62561-5 with lockable Jam free lid suitable for safe working load 60 kN of round / square size 250 mm, and Height 250 to 300 mm. and embodying the pipe complete with alternate layers salt and coke/ charcoal, testing of earth resistance for value of 5 ohms or less as required.
253SITC of Copper Bonded rod Earthing with high tensile strength (more than 600 N / sq.mm low carbon steel rod molecularly bonded with Copper thickness (250 microns) and confirming to UL 467 of following size and length and as per point mentioned (a), (b), [c), (d), (e) below :-(a) Bore a hole of dia. 100 mm of required length, Place the rod in the centre ofHole(b)Earth enhancing compound to ensure the moisture content and electrical conductivity, 25 kg for 3000 mm. The compound shall be tested form NABL accredited lab for low resistivity (less than 0.12 Ohm - meter) & high conductivity in nature with carbon as a major content in accordance with IEC62561-7© Connect the rod with copper Strip/Conductor/Wire with suitable clamp madefrom tinned copper and SS 304 Bolt(d) Place Heavy duty weather proof poly-propylene earth inspection chamber as per requirement of IS/IEC 62305 and tested as per IEC 62561-5 with lockable Jam free lid suitable for safe working load 60 kN of round / square size 250 mm,and Height 250 to 300 mm.(e) Testing of earth resistance for value of 5 ohms or less as required.(f) Test certificates for confirming above standards from OEM is mandatory.17.2 mm thick and 3 Mtr. Long
254Supply & Laying following size earth strip in horizontal or vertical run in surface by means of Earth strip DMC Insulator including riveting/ soldering/ welding, Jointing shall be done by overlapping double the width of strip and with 2 set of Brass (for Cu strip) / GI (for GI Strip) nut bolt & spring washer spaced at 50cm making connection etc. as required.25mm x 3mm copper strip
25525mm x 6mm G.I. ( Hot Dipped ) Strip
256Supply & Laying following size earth wire in horizontal or vertical run in ground/surface/recess including riveting, soldering, saddles, making connectionwith GI/Cu purity purity >95% thimble etc. as required.10 SWG G.I. ( Hot Dipped ) Wire
257Supply & Laying following size' B ' class , G.I. Pipe confirming to IS : 1239 P - 1 ( 2004 ) with accessories like bend, socket etc. for laying earth conductor/ strip cable in ground/ surface/ recess as required. (Earth Excavation will be PaidExtra)100 mm dia.
258Supply & Fixing of phenolic laminated board of 6.0 mm thick for fresh air fan/exhaust fan up to size of 300 mm on existing window frame including costof board, cutting of hole , Nut bolts etc. as required.
259Installation , testing and Commissioning of ceiling fan (any size) including wiring the down rod up to 30 cm with 3 x 1.5 sq.mm pvc insulated flexible copper conductor, Cotter pin, rubber grommet making connection testing etc. asrequired.With regulator
260Providing & Fixing BLDC technology step regulator compatible ceiling fan, with aluminium body & aluminium blade, power factor not less then 0.9 , following service value (CMM/W) , with following air delivery , speed 350 RPM ( tolerance as per IS:374 2019 ) THD less then 10%, copper winding with class of Insulation 'F' complete with with secondary support safety cable ( steel rope), down rod up to 30 cm, cotter pin, shackle kit with 3 x 1.5 sq.mm pvc insulated flexible copper conductor making connection testing etc. as required1200 mm sweep with Air delivery >/= 230 CMM and Service Value 8.20.
261Providing & Fixing of 400 mm Sweep BLDC technology Oscillating type Wall mounting / Pedestal type fans with Three speed, ON and OFF position, Double Wall bearing with front and back 120 or more ribs guard; Three no. blades, noise level should be <= 75 dB, including fixing with anchor bolts, making connection testing etc. as required. ( With Remote )Wall mounting type with Service value 2.0 CMM /W, Min. Air Delivery 71CMM
262Providing & Fixing of Heavy duty capacitor start, copper wound Double ball bearing 900/1400 RPM single phase Exhaust fan conforming to IS:2312 marked in existing opening including making connections testing etc. as required.300 mm sweep(900 RPM)
263450 mm sweep(1400 RPM)
264Providing & Fixing of Vertical(BEE 5 star rated) / Horizontal( BEE 3 star rated) storage water heater with outer casing made of Engineering Plastic sheet (Upto 25 Ltr) / Metal rust proof Body (35 & 50 Ltr), Glass - line / Titanium Enamel coated Pressure Pump Compatible 8 bar pressure Inner tank, Glass Line Coated , mineral filled heating element, stem type, snap action adjustable thermostat , Dual indicating lamps Injected PUF insulation, Multi Function Valve etc. as required held in position with 2/4 no. 10/12 mm anchor Fastener, duly wired with 3 core 2.5/4.0 Sqmm PVC insulated & sheathed copper conductor and 16 A/25A three pin plug top , including making inlet, outlet Flexible alloy connection, testing etc. as required.10 Ltr.
26525 Ltr.
266SITC of IP20 SMD Mid Power LED batten type integrated light fixture made from Powder coated Extruded aluminium housing with in built driver , System lumen efficacy ≥ 110 lm/Watt output only at CW (5700K to 6500K) , internal surge protection of 4.0 KV with Short & Open circuit protection ,THD < 10% ,\P. F.≥0.95, CRI >80 , life time of minimum 50000 Burning Hours with , 70% of intial Lumen maintaned till life ends , CCT 3000°K / 4000°K / 5700°K/6000°K/6500°K (As per ANSI Bin) as required.1170mm(+/-10%) LED batten with min. lumen output 2200 lm
267SITC of IP-20 LED Recessed / Surface Mounted, Round / Square backlit & SMD Mid Power LED Downlight with power coated die-cast aluminum housing with UV Stabilized non yellowish Diffuser with BIS compliance 4.0 KV surge protected Isolated driver, with Short & Open circuit protection input 320VAC-48 hr protection, input 350VAC-2 hr protection), having efficiency > 85% . System Lumen efficacy of ≥ 110 lm / watt,at CW (5700K to 6500K) , THD < 10 % , Pf.≥0.95, CRI >80, life time of minimum 50000 Burning Hours with , 70% of intial Lumen maintaned till life ends , CCT 3000°K / 4000°K/ 5700°K/6000°K/6500°K (As per ANSI Bin) as required.Recessed MountingMinimum lumen output 1300 lm
268Minimum lumen output 1600 lm
269Surface Mounting (with extruded alumn. Housing )Minimum lumen output 1300 lm
270Minimum lumen output 2400 lm
271SITC of IP20, 2'x2' LED Surface/ Recessed mounting backlit & SMD Mid power type LED Light fixture not less than 35 mm housing depth made from CRCA sheet steel housing, high purity / transmissivity UV stabilized Non - yellowish diffuser for uniform light distribution. operating voltage range 140-285 V, HV cutoff - LV cutoff should be 300-100V . High efficiency with 4 KV internal surge protection BIS certified isolated driver having efficiency > 85% , with Short & Open circuit protection ( input 320VAC-48 hoursprotection,input 350VAC-2 hours protection) (Integral with light fixture). System lumen efficacy of ≥ 120 lm/Watt ,THD < 10 % , p.f.≥0.95,CRI >80 , life time of minimum 50000 Burning Hours with , 70% of intial Lumen maintaned till life ends , CCT 3000°K / 4000°K / 5700°K /6000°K/6500°K (As per ANSI Bin) as required.Recessed MountingMinimum lumen output 4800 lm
272SITC of Suspended mounting IP66 IK08 rated Integrated High power LED Wellglass light fixture made from Pressure Die Cast Aluminium housing, potted driver, Eye bolt for mounting, PC clear / Opal Diffuser, system lumen efficacy ≥130 lm/Watt output only at CW (5700K to 6500K) , THD < 10%,p.f.≥0.95,CRI >70 , life time of minimum 50000 Burning Hours with , 70% of intial Lumen maintaned till life ends , CCT 3000°K / 4000°K / 5700°K/6000°K/6500°K (As per ANSI Bin) , maximum power consumption should not more than the specified rating surge protection 4 KV inbuilt & 10 KV external inside fixture as required.Minimum lumen output 4550 lm
273SITC of energy efficient /energy saving IP 20 LED direct retrofit Bulb in existing holder or fixture as required with system lumen efficacy ≥100 lm/Watt output ,pf 0.95 , CRI >70, minimum life time of minimum 25000 Burning Hours with , 70% of intial Lumen maintaned till life ends , CCT 3000°K / 4000°K / 5700°K /6000°K/6500°K (As per ANSI Bin) as required.9 Watt
274SITC of IP65 IK08 rated Integrated SMD Mid power LED bulk head type light fixture made from Pressure Die Cast AL housing suitable with integral driver, system lumen efficacy ≥120 lm/Watt output only at CW (5700K to 6500K) , THD < 15% ,p.f.≥0.95,CRI >80 , life time of minimum 50000 Burning Hours with , 70% of intial Lumen maintaned till life ends , CCT 3000°K / 4000°K / 5700°K /6000°K/6500°K (As per ANSI Bin) as required.Minimum lumen output 1200 lm
275Providing & Fixing of IK08 IP65 / IP66 protected LED Up - Down Luminarie Wall / Surface mounting made of powder coated die cast alluminium housing with with UV stabalized PC diffuser. The System level Luminous efficacy ≥ 80 Lumen/W. COB LEDs is to be used, System CRI>70, CCT: 3000/4000/6500 K. The integral electronic driver must be potted & has a unique BIS R number constant current and Internal/external surge protection device of min. 4KV(L-N) and efficiency > 85%, PF>0.9, THD<10% and input Voltage range of 140-270V AC at 50Hz. System life of 50000 Burning hours with 70% of Initial Lumens maintained Light output in Cool white or Warm White Colour as per engineers choice. LED driving output current <750mA. as required.Minimum lumen output 1300 lm Up-Down Luminary
276Minimum lumen output 2150 lm Up-Down Luminary
277Providing and Laying RCC Foundation for Octagonal / Conical Street Light poles as per Drawing attach at Table P-05 with Following ProcedureA) Excavation of Pit for Foundation Size upto required depth from Ground levelB) Dressing of Pit and Dry stone pitching 200 mm thick including supply ofstones and preparing surface complete.C) Providing and laying in position cement concrete of M-10 grade of 75 mmthicknessD) Reinforcement for R.C.C. work with TMT bars including straightening, cutting, bending, placing in position and binding all complete.E) Centring and shuttering including strutting , propping etc. and removal ofform work for Footing and PedestalF) Providing & Fixing of 2 no. Required Size PLB HDPE Pipe & Foundation Bolt with template as per OEM Recommendations.G) Providing and Laying Reinforce cement Concrete of M-20 grade in Footing and Pedestal including Curing the foundation for minimum 7 days.H) Providing and Fixing Nosing Angle 25 mm x 25 mm x 3mm with 2 no. of100 mm long, 6 mm dia fastenerPole Foundation for Octagonal pole from 3 Mtr. To 6 Mtr.
278Pole Foundation for Octagonal pole from 7 Mtr. To 9 Mtr.
279SITC of 30 Watt speaker with taping facility having frequency range of 65Hz- 20KHz@(-10db) with power handing of 200Watt continuous and more than 350 Watt @peak etc complete as required.
280Supply & Installation of 240 Watt Mixer Amplifier Unit- for providing a crisp call or clear music with 4 microphone / line inputs, plus music source input, announcement only output, 3 wire volume override, with Mains power supply 230 VAC ±10%, 50 Hz (reduced power at lower mains), Inrush current 20 A , Power consumption 120W, Frequency response (Line) 80 Hz to 18 kHz (+1/‑3 dB @‑10 dB ref. rated output) Frequency response (Mic.) 80 Hz to 18 kHz (+1/‑3 dB @‑10 dB ref. rated output) Distortion <1%@ rated output power, 1 kHz Bass Control Max. ± 8 dB Treble Control Max. ± 8 dB, including making connection etc complete as required.
281Providing & Fixing of IP-65 Protected LED aviation obstruction light luminaire comprising of die cast aluminium alloy housingwith Polycarbonate enclosure having more than 200 No's Low Power LED's having minimum powerconsumption 15 watts complete in all respect.aviation obstruction LED light luminaire 12/15 Watts
282Providing & Fixing of IK07 IP65 protected Top/Bottom mounted LED Post top Luminarie top & bottom made of single piece construction powder coated die cast alluminium housing with UV stabalized Clear / frosted Polycarbonate diffuser and Aluminium anodised with powder quoted reflector. The System level Luminous efficacy ≥ 80 Lumen/W. SMD LEDs is to be used, System CRI>70, CCT: 3000/4000/6500 K. The integral electronic driver must be potted & has a unique BIS R number constant current and Internal/external surge protection device of min. 4KV(L-N) and efficiency > 85%, PF>0.9, THD<10% and input Voltage range of 140-270V AC at 50Hz. System life of 50000 Burning hours with 70% of Initial Lumens maintained . LED Driving output current<750mA as required.Minimum lumen output 2800 lm Post top Luminarie
283Providing & Fixing of IK08 IP-66 protected high power LED flood light system with single piece Pressure diecast aluminium housing, toughened glass with suitable lenses on LED / integrated lens diffuser to achieve various beam angles, of high power LED of 3 to 5 watt each . Integrated metal case potted driver as a unique BIS R number (as per IS 15885) having efficiency more than 85 % and in compliance to BIS certified and Trade mark certificate(Fitting & driver both have separate BIS R number). The System level Luminaire efficacy >=130 lm/ wt. LED driver Input Voltage AC 120 to 270 V AC with High voltage Cutoff @>=300 V AC & Low Voltage cutoff @>=90 V AC and Auto resetting Safety.Power Factor >0.95 , THD(I) <10% , LED driving output current <=750mA. driver should be Phase to phase protection of 440 V for 4 Hrs. Electrical Connector , Surge Protection Min >=4KV internal and 10KV external but inside driver compartment, System life of 50000 Burning hours with 70% of Initial Lumens maintained, CRI>70 and CCT 5700K ±355K as required.High Power LED Flood Light Minimum lumen output 13000 lm
284Providing & Fixing of IK08, IP 66 protected LED Street Light Luminaire on existing bracket/pole. Fixture made of powder coated single piece pressure die cast aluminum material with heat dissipation fins on housing and secondary lens on each LED/ integrated lens diffuser without cover & should be High power LED of 3 to 5 watt each . The System efficacy >=135 lm/ wt and integrated metal case potted driver & has a unique BIS R number ( as per IS 15885) with Input Voltage AC 120 to 270 V AC with High voltage Cutoff @>=300 V AC & Low Voltage cutoff @>=90 V AC and Auto resetting Safety , Power Factor>0.95 driver Efficiency >85% ,THD(I) <10% Humidity 10% to 90% RH Working Temp -5C to 45C . LED driving output current <750mA. The luminaire shall be BIS certified (Fitting & driver both have separte BIS R number) and Trade mark certified. Life Expectancy Equal or more than 50000 burning hrs with Minimum 70% lumen maintened , CRI >70 and CCT 5700K+355K. Surge protection shall be min ≥ 4 KV internal and min 10 KV external inside driver compartment. driver should be Phase to phase protection of 440 V for 4 Hrs as required.LED Street Light fixture with Minimum lumen output 8100 lm
285Supply and erection of Galvanized Iron pole with galvanizing done in single dipping (Average coating thickness Minimum 65 Microns) continuously tapered poles having Octagonal / Circular/ Conical cross-sections designed to withstand the maximum wind speed as per IS 875, The pole shaft shall be made from sheet steel (HT Steel Conforming to grade S355JO) and confirming to BSEN 10025 and shall be continuously tapered with single longitudinal welding. There shall not be any circumferential welding. The welding of pole shaft shall be done by Submerged Arc Welding (SAW) process. pole shafts shall be provided with the rigid flange plate of suitable thickness (Fe 410 conforming to IS 226 / IS 2062) with provision for fixing 4 no. foundation bolts, The base plate shall be fillet welded to the pole shaft at two locations i.e. from inside and outside.The octagonal Poles shall have hinged lockable door of approximate 500 mm length at the elevation of 500 mm from the Base plate with bakelite sheet having 6A SP MCB and 16 sqmm stud type connector ( 4 nos) inside the pole at door opening for cable connection of following length and dimension as per table P-01 for Octagonal & P-02 for Conical with base plate and foundation bolt on the Existing cement concrete foundation. To ensure quality of product it's entire manufacturing process starting from sheet cutting to galvanization sould be done under one premises.Poles with Octagonal/Conical Cross Section3 Mtr.
2868 Mtr.
287SITC of Radial / mixed flow water and anti-corrosive liquid filled submersible motor pump sets suitable for 100/150mm dia borewell. The size of adopter fixed on top of the motor should exceed the top of coupler , for safegaurd the coupler. The job includes labour part of lowering of riser pipe G.I./ H.D.P.E. with rope, cables & pump, installation of complete fitting and accessories, jointing of electrical cables up to Starter. All labour for testing of submersible pumps set and supply of water to water mains, complete in all respect.100 mm diameter Submersible pump shall have following HP Rating, phase,Head range, Discharge range respectively.2.0 HP, 1-Ø, (7- 95)Mtr, (55-22) LPM
288SITC of IP 54 OEM Fabricated DOL/Star-Delta Starter panel with switchgear selection as per Type-2 Coordination Chart and made out from 1.6 mm thick powder coated CRCA sheet, enclosure comprising of over load protection relay, short circuit & single phasing protection(for three phase pumps), Illuminated ON/ OFF push buttons, ammeter, voltmeter, indicating lamps, 2P/4P MCB etc. suitable for following rating motors complete in all respect.For single phase Submersible / Monoblock pump2.0 HP to 3.0 HP (DOL starter)
289Providing & Fixing of IS : 4985 - 2000 Class -4 (10 Kgf / Sqcm) UPVC drain water piping with fittings (IS:7834 & 10Kgf/sqcm) like elbow, socket, Tee, solvent cement jointing, support with MS hanger on ceiling or recessed in wall with chasing & plastering with 6 mm thick closed cell elastomeric nitrile rubber insulation including leakage testing etc. as required of following Nominalsizes.20 mm
29025 mm
291Making hole in stone masonary/ RCC wall/ RCC slab with core cutter for accomodating refrigerant pipe/ drain pipe/ MS pipe/ cables etc of following dia100 mm dia per running inch length
292Supply & fixing MS powder coated stand suitable for 1.0/1.5/ 2.0 Tr outdoor typeof Split AC. All as per pre approved by Engineer in charge.
293Supply & fixing MS powder coated stand suitable for 2.5/3.0/4.0 Tr outdoor type of Split/Ductable/Tower AC. All as per pre approved by Engineer in charge.
294SITC of Interconnecting refrigerant copper pipe for split/Ductable/ Casseette AC of DHE Grade C12200- ASTM B68, B75, chemical composition of copper%- 99.0 Min and Phosphorus %- 0.015 to 0.040 . For Annealed copper tube :- Tensile strength = 210 Mpa wih elongation % = 40 Min . Ink Mark Brand Printing on Hard Tubes should be present. Piping between each set of indoor & outdoor units of different sizes as per OEM requirement & specifications including class 'O' Nitrile rubber sleeves (size as per item no. 22.43),7 mil Glass Cloth with 3 coats of anti UV paint (on area which is exposed to weather) chase cutting, supports, making good the same with sand cement plaster etc. asrequired.
295SITC of following diagonal size professional Display, 4k Resolution, Brightness(Typ.) 440 nit and above , Contrast Ratio-2000:1 and above, Viewing Angle(H/V)-178/178, Response Time(G-to-G) 8ms, Input: RGB- Analog D- SUB, Video- HDMI 2.0 (2), HDCP- HDCP 2.2, Audio- Stereo mini Jack, USB- Only F/W upgrade, Outputs: RGB- DP1.2(Loop- out), Audio- Stereo mini Jack, External Control- RS232C(in/out), RJ45, External Sensor Detachable type(IR Ambient). Operation Hour 24/7. mounting bracket etc. as required.43\\" ( for Rooms )
29655\\" ( for Camera display / dinning Room )
297SITC of following capacity BIS certified 1Phase Input, 1Phase Output advance DSP controlled IGBT based rectifier Online UPS with 0.99 Input power factor &0.8 Output factor, having Input voltage & frequency range of 180-300V on full load/ 110-300V on 60% load & 50 Hz +/- 5% and output voltage & frequency of 230V+/-1% & 50 +/- 0.1 Hz.Overloading of 105 - 110% 10 mins, 111 - 130% 2 mins,131 - 150% 30 sec, THDv of < 3% for Linear & < 5% for Non linear load.UPS should have LCD display showing load level, Battery Voltage Level, Input & Output Voltage, Input & Output Frequency. UPS should have protection from Input High / Low;Over Load;Short Circuit; Over Temperature and give audible alarms on Battery Mode;Low Battery;Fault;Over Load & Bypass Mode.SMF Batteries of 12V VRLA for 30 min back up with MS Rack and necessary cable for UPS to Batteries Installation. UPS should have CE, ROHS, IEC62040-1,2&3 compliance and should have QR code which should contain drawing, test report OEM manual,Geo- Tag of manufacturing location Etc. as required.3KVA UPS with 3024 VAH Battery
298Supplying and drawing flexible / stranded bare copper conductor, PVC / XLPE insulated, overall aluminium mylar tape shielded ATC drain wire and outer PVC sheathed industrial Instrumentation (shielded)cables voltage grade 300/500 V as per BS /EN 50288-7 in existing surface or recessed PVC/ MS conduit/casing capping / Cable tray / Open Duct making connections, testing etc. as required. OEM must ensure that the cable is tested for complaince, either through their in house laboratory accrediated by NABL or by any Govt. laboratory accrediated by NABL and the laboratory's scope of accrediation should cover the requirementsand testing procedure as per IS:10810.Un Armoured4 core x 2.5 Sq.mm
299Supply, Fixing and testing of following capacity IS:8448 marked wall mounted stabilizer having output voltage variation from 200 V to 250 V(+/-5%) with input voltage variation from 170 V to 260 V, time delay facility from 2 to 4 minute and high cutoff at 270 V with providing of 16 Amp /20 Amp Industrial plug topmaking connection etc complete in all respect.5 kVA
300Extra Amount for Other work
301P & F Indian type white glazed vitreous china 1st quality W.C. orissa pan(IS :2556 Mark) with 100 mm vitreous china P or S trap including cutting and making good the wall and floor:
302P & F Low level Flushing Cistern of 10 litres capacity (IS : 2556mark). Of approved make with complete fittings C.I. brackets duly painted, brass ball cock with ball, (IS: 1703 mark) complete including cutting and making good the wall:PVC with PVC bend as per IS : 7231 .
303P & F European type white glazed vitreous china 1st quality Double syphonic W.C (IS :2556 Mark) with P or S trap including cutting and making good the wall and floor
304P & F WVC Wash basin (Ist quality IS:2556 Mark) of approved make with C.I. brackets duly painted 1 No. 15 mm C.P. Pillar cock (IS:8934 Mark) & 32 mm C.P. brass waste coupling of approved make, P.V.C Waste pipe with PVC nut 32 mm complete including cutting & making good the wall :Size 550 mm x 400 mm
305Size 610 mm x 510 mm
306Add extra for using 25mm GI waste pipe instead of PVC waste pipe
307P & F Bevelled edge Mirror/mirror with teak wood lipping around of special glass of approved make as per direction of Engineer-in-charge complete with 6mm thick commercial ply base fixed to wooden screws & washers.
308P& F waste Pipe with all fitting P.V.C. with C.P. nut 40 mm dia
309P & F lst quality WVC Urinal (IS:2556 mark) with 25mm dia G.I. waste pipe, dome waste couplings, concealed iron brackets or screws etc complete.
310P & F Automatic Flushing Cistern of first quality (IS : 774 mark) of approved make fitting, siphon with copper tube, C.I. brackets complete including cutting and making good the wall. WVC (as per IS : 2556) 10 litres.
311P&F Marble Urinal Partition slab both sides polished of approved design cut from marble size 900x600mm.
312P & F C.P. brass Urinal Flush Pipe set complete with flanged brackets of approved make.
313P & F 15 mm. Dia Connection Pipe of approved quality/make : PVC pipewith C.P. Brass nuts upto length, 450 mm
314P & F C.P. Health Faucet with 1Mtr. Long Tube & Hook of approvedmake and heavy as per direction of Enginner-inCharge
315P & F Inlet Connection (Angle Valves) Superior quality, of approvedmake, for Wash basin, Gyser etc.
316Providing & Fixing Premium quality Bottle trap internal portion 32mm,size 250mm long wall connection pipe & wall flange as per approved by Engineer in Charge.
317P & F Liquid Soap Container with brackets complete of approved make:
318P & F Towel Rail or Ring of approved quality/make:
319P & F Grating of approved quality/make:
320Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. (Concealed work including cutting chases and making good the walls etc.,)20mm dia nominal outer dia pipes
32125mm dia nominal outer dia pipes
322Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge. (Internal work Exposed on wall)32mm outer dia pipes
32350mm outer dia pipes
324Supply & fixing G.I. Union ISI marked in G.I. pipe line as required complete in all respect of size :20mm dia nominal bore
32525mm dia nominal bore
32650mm dia nominal bore
327P & F Full-way Valve (IS:778 Mark) or wheel valve of approved make :Gunmetal 25mm nominal bore.
328P & F PVC Storage Tank ISI Marked (IS : 12701) indicating the BIS license No), of approved make with cover, 25mm dia 1M long G.I. over-flow pipe & 25 Cm. long wash out pipe with plug & socket, including making connection etc., complete of approved design: 1000 litrescapacity.
329Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge. (Internal work Exposed on wall)
330P & F Full-way Valve (IS:778 Mark) or wheel valve of approved make : (do-) 50mm nominal bore.
331Providing, lowering, laying, aligning, fixing in position and jointing in pipe line CI Kinetic Double Air Valves as per IS:14845 of following dia (including jointing and jointing material), including all material, labour, testing and commissioning as per Technical Specifications and as per direction of Engineer.
332SITC of Dewatering Submersible Motor Pump set, motor should be IE2 class as per IEC 60034-2-1: 2007, IEC 60034-30: 2008, & IS12615:2011. with SS Impellor, body, shaft, mechanical seal etc. as required. Pump shall have following HP Rating, phase, Head, minimum Discharge respectively complete in all respect. OEM shall have submit NABL / CPRI / ERDA accrediated lab type test certificate before execution. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure \\"A\\" attached with this BSR .
333P & F Sand-cast Iron (S.C.I.) Pipe (IS : 1729mark) of approved make in wall or in floor with M.S. holder bat clamps in 10 X 10 X 10 Cm. M-15 grade concrete blocks, joints filled with CM 1:4 with spun yarn including cutting holes and making good the wall:100 mm dia
334150mm dia
335P &F S.C.I. Fittings (IS : 1729 mark) in CM 1:4 with spun yarn. Ofset
336Socket
337D/door Y-Tee
338Cowel
339Door Cross
340Construction of septic Tank in all types of soil with 40 Cm .thick masonry in CM 1:6, 15 Cm thick C.C bed of 1:5:10, M-15 grade C.C floor & RCC slab covering with M15 grade c.c. floor, 50 mm thick stone slab partition walls, 20 mm thick plaster in CM 1:6 finished with neat floating cement, 4 Nos stone foot rests of approved design ,two No. 450 mm dia Each Ferro cement cover with frame, earth work etc. complete as per approved drawing including disposal of surplus earth within a lead of 50Mtr:-
341Construction of soakage well in all type of soil with 300 mm thick dry masonry, top and bottom 300 mm course in CM 1:6, 80mm thick stone slab, jointing of slab in CM 1 : 3, Ralthal, Kharanja, 40 mm thick M-15 grade C.C flooring , earthwork complete as per approved drawing including disposal of earth within a lead of 50 Mtr.:
342Constructing brick masonry road gully chamber 50x45x60 cm with bricks of class designation 75 in cement mortar 1:4 (1 cement : 4 coarse sand) including 500x450 mm precast R.C.C. horizontal grating with frame complete as per standard design :
343Constructing brick masonry road gully chamber 110x50x77.5 cm with bricks of class designation 75 in cement mortar 1:4 (1 cement : 4 coarse sand) including 500x450 mm precast R.C.C. horizontal grating with frame and vertical grating complete as per standard design :
344CONTENGENCY 1.5%
345Supplying, Installation, Testing & Commissioning of Electrical Driven fire fighting duty pump as per TAC and IS 12469-1988., Factory assembled in Pump make OEM for Sprinkler / Hydrant applications suitable for automatic operation and consisting of following details given as A, B, C, D, E, F, G and H.(A) End Suction / Horizontal Axially split casing volute typeSingle / Multi stage Centrifugal pump complete for delivery ofbelow mentioned discharge and Head(B) Material of construction : Pump Casing- Cast Iron,Impellor- Bronze, Shaft- SS 410, Packing- Mechanical Seal(C)Pump shall be capable of furnishing not less than 150 % of rated capacity at a head not less than 65 % of the rated head. The shut off head shall not exceed 120 % of rated head(D) Squirrel cage induction motor (IE-3 Class) suitable for 3 phase, 415 V, 50 HZ, Ac supply , Class-F Insulation,Synchronous speed 2900 / 1500 RPM, T.E.F.C confirming to IP:55 , of required HP suitable for the above pump ,along with flexible (Love Joy type) coupling , coupling guard complete in all respect .( E) Common bed plate fabricated from mild steel channel for installation of pump and Motor including anti vibration pads.(F) The Hydrostatic tests (2 times of design operating heador 1.5 times the shut off head whichever is higher) and performance tests (to determine developed head, Pump BHP and efficiency v/s Flow) of pumps along with trip test shall be carried out at manufacturer‟s works in Physical presence of Department‟s representatives.(G) Physical & Chemical Test reports of i) Pump casing (ii) Impeller (iii) Shaft (iv) Shaft sleeve and Dynamic Balance certificate is to be submitted by OEM(H)Suitable size Reinforced cement concrete (M-30) foundation with foundation bolt, Nozing Angle of size 40mm x40mm x5 mm ( Cost of RCC Foundation to be paid Extra ). All as per pre approved by Engineer in charge. For1620 LPM suitable for 56 Mtr Head End Suction Back pull type Single Stage, 2900 RPM
346Supplying, Installation, Testing & Commissioning of Diesel Engine Driven fire fighting duty pump as per TAC and IS 12469-1988., Factory assembled in Pump make OEM for Sprinkler / Hydrant applications suitable for automatic operation and consisting of following details given as A, B, C, D, E, F, G and H.(A) End Suction / Horizontal Axially split casing volute type Single / Multi stage Centrifugal pump complete for delivery of below mentioned discharge and Head (B) Material of construction : Pump Casing- Cast Iron, Impellor- Bronze, Shaft- SS 410, Packing- Mechanical Seal(C)Pump shall be capable of furnishing not less than 150 % of rated capacity at a head not less than 65 % of the rated head. The shut off head shall not exceed 120 % of rated head (D) Heat Exchanger cooled Diesel Engine as per NFPA 20 developing suitable BHP for the below mentioned discharge at 1500 / 1800 RPM, flexible coupling and coupling guard with the Pump, common bed plate for mounting of the Engine and Pump,Antivibration damping arrangement by cushy foot, Diesel Engine starting Panel for starting of the engine automatically if the Normal electrical supply fails with a unit of battery bank of 12/24v,180 Ah, Lead Acid Battery with Boost / Trickle charger as required for operation of Diesel engine, Exhaust Pipe of suitable diameter upto 10 M length (with LRB insulation & Alum. Cladding), with muffler, Diesel tank of 300 Lts capacity (made out from 2 mm thick MS sheet with filling Cap) with drain cock, Diesel level Indicator, Suitable MS angle iron stand for placing tank, first Filling of Diesel tank.(E) Diesel Engine Control comprising Automatic/Manual selctor switch & 3 attempts starting device, timers and relays as required, push buttons, start/stop in manual mode Indicating lamp for high/ Low Lub. Oil pressure, High Water Temp and Engine on indication, Battery charger suitbale for 12V/24 V DC with boost and trickle selector switch, 0-30 V DC volt meter, and 0- 20 A DC Ammeter, All standard relays and accessories for automatic operation of diesel engine System Controller in Existing Fire Fighting Control panel (F) The Hydrostatic tests (2 times of design operating head or 1.5 times the shut off head whichever is higher) and performance tests (to determine developed head, Pump BHP and efficiency v/s Flow) of pumps along with trip test shall be carried out at manufacturer‟s works in Physical presence of Department‟s representatives. (G) Physical & Chemical Test reports of i) Pump casing (ii) Impeller (iii) Shaft (iv) Shaft sleeve and Dynamic Balance certificate is to be submitted by OEM (H) Pump to be placed on Suitable size Existing Reinforced cement concrete (M-30) foundation with foundation bolt, Nozing Angle of size 40mm x40mm x5 mm ( Cost of RCC Foundation to be paid Extra ). All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure \\"A\\" attached with this BSR1620 LPM suitable for 56 Mtr Head End Suction Back pull type Single Stage, 1800 / 2300 RPM
347Supplying, Installation, Testing & Commissioning ofElectrical Driven fire fighting duty Jockey pump as per TAC and IS 12469-1988., Factory assembled in Pump make OEM suitable for automatic operation and consisting of following details given as A, B, C, D, E,F and G(AHorizontal End suction Single / Multi Stage CentrifugalBack pull type pump complete for delivery of belowmentioned discharge and Head(B) Material of construction : Pump Casing- Cast Iron,Impellor- Bronze, Shaft- SS 410, Packing- MechanicalSeal(C)Squirrel cage induction motor (IE-3 Class) suitable for 3 phase, 415 V, 50 HZ, Ac supply , Class-F Insulation, Synchronous speed not Exceeding 2900 RPM, T.E.F.C confirming to IP:55 , of required HP suitable for the above pump ,along with flexible (Love Joy type) coupling , coupling guard complete in all respect .(D) Common bed plate fabricated from mild steel channelfor installation of pump and Motor including anti vibration pads.(E) The Hydrostatic tests (2 times of design operating heador 1.5 times the shut off head whichever is higher) and performance tests (to determine developed head, Pump BHP and efficiency v/s Flow) of pumps along with trip test shall be carried out at manufacturer‟s works in Virtual / Physical presence of Department‟s representatives.(F)Physical & Chemical Test reports of i) Pump casing (ii) Impeller (iii) Shaft (iv) Shaft sleeve and Dynamic Balance certificate is to be submitted by OEM(G)Suitable size Reinforced cement concrete (M-30) foundation with foundation bolt, Nozing Angle of size 40mm x40mm x5 mm ( Cost of RCC Foundation to be paid Extra ) All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure \\"A\\" attached with this BSR . 180 LPM suitable for 56 Mtr Multi Stage
348SITC of suitable Pressure release valve of 50 mm dia, of CI body, with pressure setting range 7-15 kg/sqcm, on discharge header / Air Vessel, complete in all respect etc. as required. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure \\"A\\" attached with this BSR
349Providing & fixing pressure transducer in M.S. Pipe line(pressure range 0 to 10 kg/cm2) suitable for 12 volts/24 volt DC. Including connection etc. as required. ( Control Cable from Pressure Transducer to Panel to be Paid Extra ). All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure \\"A\\" attached with this BSR .
350Providing, Fixing, Jointing, Testing & Commissioning ofHeavy duty MS 'C ' class (Heavy) pipes conforming to IS 3589 / 1239 part-I for hydrant and sprinkler applications including cutting, screwing, welding etc. & forged steel fittings like elbows, tees, tapers, reducer, gaskets etc. fixing the pipe on the wall/ceiling with suitable clamps, hanger and nuts bolts including cutting hole and chase in brick or RCC walls/ slab and making good the same. complete with painting of one coats of Red Oxide and two or more coats of synthetic enamel paint of required shade complete as required. (Pipe to be tested @ 10Kgf/Sqcm for 2 Hrs.). All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure \\"A\\" attached with this BSR .80 MM DIA.
351100 MM DIA.
352150 MM DIA.
353Providing, Fixing, Jointing, Testing & Commissioning ofHeavy duty MS 'C' class (Heavy) pipe conforming to IS 3589 / 1239 part-I for hydrant and sprinkler applications in Existing trench with cement concrete block as supports including cutting, welding etc & forged steel fittings like elbows, tees, tapers, reducer with cleaning,wrapping and coating of the pipe with 4 mm thick tar based polymaric corrosion protection tape including applying uniform coat of cold pipekot primer as per IS; 10221 for protection against corrosion complete in all respect. ( Pipe to be tested @ 10Kgf/Sqcm for 2 Hrs. & Excavation of Trench and refilling of trench to be paid extra). All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure \\"A\\" attached with this BSR . 80 MM DIA.
354100 MM DIA.
355150 MM DIA.
356Supplying and fixing cylindrical air vessel of continuous welded construction for pump room made of 450 mm dia,fabricated out of 10 mm thick dished ends and 8 mm thick MS sheet, 2000 mm in height with flanged connection, Provision for 25 mm dia drain valve,air release valve,safety valve pressure gauge as required accessories and painting with two coats of Red Oxide and two coat of post office red enamel paint including The tank shall be installed on suitable vertical legs. The legs shall be provided with M.S. Angle of size 75 mm x 75 mm x5mmat thebottom. The legs shall be grouted in cement concrete foundation. as required. ( Air Release valve, Drain valve, PRV, Pressure Gauge shall be Paid Extra ). All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure \\"A\\" attached with this BSR .
357Supplying and Fixing of PN 16 Flanged Y strainer fabricated out of cast iron body, SS 304 strainer with perforated screen with 3 mm. dia holes in existing MS / GI pipe complete with 2 no. Matching Flanges (Minimum 16 mm thick), nuts, bolts, washers, gaskets etc as required of following sizes. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure \\"A\\" attached with this BSR .
358Supplying and Fixing of PN 1.6 Butterfly Valve (Wafer Type) with S.GIron Discand confirming to IS:13095 complete with 2no. Matching Flanges (Minimum 16 mm thick), nuts, bolts, washers, gaskets, etc as required of following sizes.All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure \\"A\\" attached with this BSR .
35980 MM DIA.
360100 MM DIA.
361150 MM DIA.
362Supplying and Fixing of PN 16 Brass/ GM Ball valves with screwed end,SS Ball including teflon tape etc.as required. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure \\"A\\" attached with this BSR .
36320 MM DIA.
36425 MM DIA.
36550 MM DIA.
366Supplying and fixing of SS 304 Single / Double headed oblique pattern hydrant landing valve (internal/external) with 75 / 100 mm dia flanged inlet & 63 mm dia instantaneous type female outlet coupling with cast iron wheel complete with ABS cap and chain and all accessories as per IS:5290 93 (Type-A) in cluding matching flange (14 mm thick), nuts, bolts, washers, gaskets, etc as required. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure \\"A\\" attached with this BSR .
367Supplying and fixing orifice plate made of 6 mm thick stainless steel with orifice of required size in between flange & landing valve of external and internal hydrant to reduce pressure to working pressure of 3.5 kg/cm2 complete with rubber gasket, GI bolts, nuts, washers etc. as required. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure \\"A\\" attached with this BSR .
368Supplying and fixing of flexible hose made with 100% polyester, black EPDM internal rubber lining with External coat of synthetic elastomer (IS:636, type-A) 63 mm dia, 15 mtr. Long RRL hose pipe with instanteneous type 63 mm dia SS-304 male and female couplings (IS:903) duly bound and riveted to hose pipes with copper rivets and SS wire etc. as required.Appropriate Test Certificate/ report with liable warranty of product/accessories from OEM shall be submitted.
369Supplying & fixing SS-304 Short Branch Pipe conforming to IS: 903:93 fitted with 20mm (nominal internal diameter) bore nozzle, for projecting water in form of solid jet. The Branch shall have 63mm Male Instantaneous Inlet, suitable for use with 63 mm size Fire fighting hoses. H.P. tested to 21 kgf/cm² for 2.5 minutes. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure \\"A\\" attached with this BSR .
370Supplying and fixing first-Aid Fire hose reel Drum wall mounted swinging type with MS construction powder painted in post office Red, conforming to IS 884-1985 with upto date amendments, complete with the following as required. (A) Thermoplastic / Rubber Hose (B)20 mm dia UL, FM Bronze / SS nozzle with 5mm orifice (C)Drum and brackets for fixing the equipments on wall. (D) Connections from riser with 20/25 mm dia Brass/GM gate valves with screwed end and conforming to IS:778 Class-1 through Forged steel Screwed Union & M.S. pipe. Etc. as required. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure \\"A\\" attached with this BSR .
371Supplying and fixing Inlet Breeching Connection of CI body with Gun Metal male instantaneous inlet couplings with Inbuilt NRV, Drainage Connection with 50 mm Brass gate valve complete with PVC blank cap and chain as required for 150mm dia Outlet with 1 no. Matching Flange (Minimum 16 mm thick), nuts, bolts, washers, gaskets, etc as required of following Ways. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure \\"A\\" attached with this BSR .
3722 Way
3734 Way
374Providing and fixing of 100 mm Dia. Flanged Gun Metal Fire brigade Suction hose coupling (draw out connection) for female coupling as per IS:902-1974 complete with Matching Flange (Minimum 14 mm thick), nuts, bolts, washers, gaskets, etc as required. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure \\"A\\" attached with this BSR
375Supply and Fixing of Cast iron body one side Flanged and other side strainer ball type foot valve with Reinforced rubber Nitrile rubber coated Ball including Matching Flange (Minimum 16 mm thick), nuts, bolts, washers, gaskets, etc as required of following Sizes. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure \\"A\\" attached with this BSR
37680 MM DIA.
377100 MM DIA.
378150 MM DIA.
379Providing and Fixing of PN16 Resilient rubber lined single arch vibration eliminators suitable for raw water up to 45 deg. C temperature, working pressure 8.5 Kg/cm2 and test pressure 14 Kg/cm2 to provide relief from stresses at pipe including Matching Flange (Minimum 16 mm thick), nuts, bolts, washers, gaskets, etc as required of following Sizes. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure \\"A\\" attached with this BSR .
38080 mm Dia. x 150 mm Oal
381100 mm Dia. x 150 mm Oal.
382150 mm Dia. x 150 mm Oal
383Supplying and fixing of 750 mm x 600 mm x 250 mm Outdoor application Fire Hose Cabinet made of 1.6 mm thick MS sheet Duly powder coated in red color externally and white internally with 6 mm thick glazed doors with Expanded Metal 2 mm thick Jali including necessary locking arrangement suitable to accommodate 2 Nos 15 Mtr. Long RRL Hose and 1 No. branch pipe on Existing Wall / Angle Iron Frame as required. (Cost of MS structure for mounting Frame is to be Paid Extra) All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure \\"A\\" attached with this BSR
384Supplying and fixing of 1000 mm x 600 mm x 500 mm Outdoor application Fire Hose Cabinet made of 1.6 mm thick MS sheet Duly powder coated in red color externally and white internally with 6 mm thick glazed doors with Expanded Metal 2 mm thick Jali including necessary locking arrangement suitable to accommodate External hydrant with butterfly valve, 2 Nos 15 Mtr. Long RRL Hose and 1 No. branch pipe on Existing Wall / Angle Iron Frame as required. (Cost of MS structure for mounting Frame is to be Paid Extra). All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure \\"A\\" attached with this BSR .
385Providing and fixing of Fire / Electrical Shaft Door made from powder coated (50 Micron) aluminium partialy glazed with 6 mm thick glass and Partialy / Fully Louvered with Outer frame of Aluminium Section of Size 100 mm x 45 mm x 1.5 mm and Shutter's Top, Middle & side Section of Size 82 mmx45mmx1.5mm,Bottom Section of Size 110 mm x 45 mm x 1.5 mm Complete with Hinges, Tower bolt, Handle, Aldrop, Locking Arrangement including dash fasteners of required dia and size, necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. as per drawings and the directions of Engineer-in-charge. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure \\"A\\" attached with this BSR
386Providing & fixing of UL listed 1.5 mm thick chrome plated Dual type MS Escutcheon plates fixed at junction of Sprinkler piping with the false ceiling. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure \\"A\\" attached with this BSR .
387Supply & Fixing of Fire Man's Axe with carbon steel head & rubber moulde handel usable upto 20 KV and confirming to IS :926 with length approx 0.4 M & weight 3.0 Kg. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure \\"A\\" attached with this BSR .
388Supply & Fixing of Trolley mounted 22.5 Kg CO2 type Fire Extinguisher conforming to IS: 16018:2012, charged with CO2 gas (purity 99.7% conforming to IS 15222), Powder coated Internal & External Surface Manganese steel ISI marked as per IS 7285 cylinder body , Wheel type Forged brass release valve ISI Marked as per IS 3224 with Inbuilt safety release device ((Fusible plug and Rupture Disc Type), 1.5 Mtr. long Metal wire braided hose having minimum bursting pressure of 140 Kgf/cm2, Horn with metallic thread connection, QR code for Product Traceability, including Double mounted handle as required of following capacity. Test Certificates of all the Parameters along with Hydro test & Burst test (For Cylinder Body) Certificate from OEM / External NABL Accrediated Lab is to be submitted. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure \\"A\\" attached with this BSR .
389Supply & Fixing of Ceiling mounted Dry Powder Agent (as per IS 4308:2019), Modular stored pressure type ABC Fire Extinguisher , Powder coated Internal & External Surface Deep drawn cylinder body of Mild Steel CR2 grade conforming to IS: 513, Fixed Bulb with Temerature 68 deg C, QR code for Product Traceability including Fixing on Ceiling with suitable Anchor Fasteners as required of following capacity. Test Certificates of all the Parameters along with Hydro test & Burst test (For Cylinder Body) Certificate from OEM/ External NABL Accrediated Lab is to be submitted. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure \\"A\\" attached with this BSR .
390Supply of 15” Linear Coaxial Speaker with an AuraWave guide, Frequency Response (-3 dB) 46 Hz - 20 kHz, Frequency Range (-10 dB) 41 Hz - 20 kHz, Rated Power 500W Continuous, 2000W Peak, Maximum SPL 136 dB, Sensitivity 99 dB, Nominal Impedance 8 Ohms, Coverage Pattern 60° x 60°, LF Driver 15\\" Coaxial Performance Driver, 3\\" VC - Ferrite, HF Driver 1.5\\" Ferrite HF Trandsucer, 2\\" VC, Crossover Frequency 1.9 kHz. Approved Make : British Acoustics/Martin Audio/L - Acoustics/D&B/MeyerSound
391Supply of 2 - Channel High Performance Amplifier Systems for Install Applications, Power at 4 Ohms (Stereo Mode, All channels driven) 1650W, Power at 8 Ohms (Stereo Mode, All channels driven) 900W, Bridged Power at 8 Ohms 3000W, Bridged Power at 4 Ohms 4000W, Dampning Factor > 400 at 8ohms, Signal to Noise Ratio (1 kHz, 8 Ohms)- 105 dB, THD < 0.02% THD / 4ohms and 8 ohms, Controls Sensitivity Selection - High Pass Cut Off - Stereo, Bridge, Parallel Switch\\". Approved Makes: British Acoustics/ Martin Audio/ Powersoft/ Lab Gruppen.
392Supply of 18\\" Passive Subwoofer, Frequency Response (-3 dB) 38 Hz - 800 Hz, Frequency Range (-10 dB) 41 Hz - 200 kHz, Rated Power 1000W Continuous, 4000W Peak, Maximum SPL 137 dB, Sensitivity 98 dB, Nominal Impedance 8 Ohms, Coverage Pattern Omni-directional, LF Driver 18\\" Ultra Long Excursion ADR Drivers, 4\\" VC - Ferrite, Inputs 2 x Speak-on Connectors, Wired Parallel. Approved Make: British Acoustics/Martin Audio/L- Acoustics/D&B/Meyersound.
393Supply of 2 - Channel High Performance Amplifier Systems for Install Applications, Power at 4 Ohms (Stereo Mode, All channels driven) 2500W, Power at 8 Ohms (Stereo Mode, All channels driven) 1300W, Bridged Power at 8 Ohms 4100W, Bridged Power at 4 Ohms 6400W, Dampning Factor > 400 at 8ohms, Signal to Noise Ratio (1 kHz, 8 Ohms) - 105 dB, THD < 0.02% THD / 4ohms and 8 ohms, Controls Sensitivity Selection - High Pass Cut Off - Stereo, Bridge, Parallel Switch\\". Approved Makes: British Acoustics/ Martin Audio/ Powersoft/ Lab Gruppen.
394Supply of 8” Linear Coaxial Speaker, Frequency Response (-3 dB)-58 Hz - 22 kHz, Frequency Range (-10 dB) 53 Hz - 22 kHz, Rated Power-300W Continuous, 1200W Peak, Maximum SPL-125 dB, Sensitivity-91 dB, Nominal Impedance-8 Ohms, Coverage Pattern-120° x 120°, LF Driver-8\\" Coaxial Performance Driver, 2\\" VC - Ferrite, HF Driver -0.8\\" Dome Compression Drivers, 1\\" VC, Crossover Frequency-2.3 kHz. Approved Make : British Acoustics/Martin Audio/L - Acoustics/D&B/MeyerSound
395Supply of 2 - Channel High Performance Amplifier Systems for Install Applications, Power at 4 Ohms (Stereo Mode, All channels driven) 850W, Power at 8 Ohms (Stereo Mode, All channels driven) 400W, Bridged Power at 8 Ohms 1600W, Bridged Power at 4 Ohms 2500W, Dampning Factor > 400 at 8ohms, Signal to Noise Ratio (1 kHz, 8 Ohms)- 105 dB, THD < 0.02% THD / 4ohms and 8 ohms, Controls Sensitivity Selection - High Pass Cut Off - Stereo, Bridge, Parallel Switch\\".
396Supply of Powered 12” Linear Coaxial Speaker with an Omniwave guide, Frequency Response (-3 dB) 49 Hz - 20 kHz, Frequency Range (-10 dB) 44 Hz - 20 kHz, Amplifier Power 500W Continuous, 1000W Peak, Maximum SPL 129 dB, Coverage Pattern 100° x 100°, Controls Individual & Master Gain Knobs, Power Switch, LF Driver 12\\" Coaxial Performance Driver, 3\\" VC - Ferrite, HF Driver 1.3\\" Ferrite HF Trandsucer, 2\\" VC, AC Power Input Universal power supply 100 - 240 VAC, 50 - 60 Hz . Approved Make : British Acoustics/Martin Audio/L - Acoustics/D&B/MeyerSound
397Supply of 2 - Channel High Performance Amplifier Systems for Install Applications, Power at 4 Ohms (Stereo Mode, All channels driven) 1650W, Power at 8 Ohms (Stereo Mode, All channels driven) 900W, Bridged Power at 8 Ohms 3000W, Bridged Power at 4 Ohms 4000W, Dampning Factor > 400 at 8ohms, Signal to Noise Ratio (1 kHz, 8 Ohms)- 105 dB, THD < 0.02% THD / 4ohms and 8 ohms, Controls Sensitivity Selection - High Pass Cut Off - Stereo, Bridge, Parallel Switch\\". Approved Makes: British Acoustics/ Martin Audio/ Powersoft/ Lab Gruppen.
398Supply of 12 inch Powered Speaker, Frequency Response (-3 dB) 60 Hz - 20 kHz, Frequency Range (-10 dB) 51 Hz - 20 kHz, Amplifier Power 850W Continuous, 1700W Peak, Maximum SPL 128 dB, Coverage Pattern 100° x 60°, Controls Individual & Master Gain Knobs, Power Switch, LF Driver 12\\" LF Driver, 2.5\\" VC - Ferrite, HF Driver 1.4\\" Titanium Compression Driver - 1\\" VC, Connectors 2 x Balanced XLR Inputs 1 x Balanced XLR Link Output Power Input, AC Power Input Universal power supply 100 - 240 VAC, 50 - 60 Hz . Approved Make : British Acoustics/ Martin Audio/TW Audio/Renkus Heinz.
399Supply of 32 Frame Compact Analogue Mixing Desk with Dual FX, Number of Input Channels 28 Mono + 2 Stereo Channels, Media Player with USB / BT input, Number of Output Channels Master L+R XLR Output, Zone L+R XLR Output (Sub), USB Intefrace Out, Recording Out (2Track), TRS Aux, Moni-r, FX Mute & Headphone Outputs, Oliver FX Dual FX Engine, Recording 2-Track Recording In/Out, USB Audio Interface Connectivity, Auxes Balanced XLR Setero Aux Out, One TRS Aux Output, Frequency Response 20Hz - 30KHz 0.5dB, Max. Input Level Mic +24dBu, Line +24dBu, Other +20dBu, Max. Output Level XLR +26dBu, TRS +20dBu, Max Input Power 40 Watts, Faders 60mm.Approved Make: British Acoustics/Soundcraft/Yamaha/Allen& Heath
400Supply of of Dual Channel 31-Band Equalizer, 1/3-octave Constant Q frequency bands, Switchable boost/cut ranges of ±6 or ±12 dB, Front panel bypass switch, ±12 dB input gain range, XLR and TRS Inpts and Outputs, Frequency Response of <10Hz to >50kHz, Dynamic range of greater than 108dB Approved Make : DBX/ OSL/ DIGICO/ Waves
401Supply of High Precision Management System : 4-inputs, 8-ouputs with advanced correction filters & dynamic PEQ for Feedback Correction. Audio Input 4xBalanced XLR, Audio Output 8x Balanced XLR, Minimum Load 150 Ohms, THD+N 0.0001% at 1kHz, Sound to Noise Ratio >110dB, AD & DA Converters 24bit-96kHz, Parametric EQ 11 filters per input selected as Bell or Shelving, Centre Frequency Selectable with a 1/24th of octave resolution step from 20Hz upto 20kHz, Crossover Section HPF/LPF Butterworth 6/12/18/24 dB per octave. Approved Make: British Acoustics/ OSL/ Biamp/Martin Audio
402Supply of Wireless Handheld Receiver with Diversity Principle: True Diversity, No. of Channels : 1, Frequency response 20-20 Khz, Frequency Selection: Auto, Modulation : Wideband FM, Attenuation : 0 to 14 Db selectable , LED Display, Range : 100 meters, With RF Shielding and Wireless Handheld Microphone Transmitter with Microphone with Display on Transmitter, Type : Dynamic, RF Power Output : 30mW, Polar Pattern: - Cardioid, Frequency response: 55 Hz to 20Khz, Mute Button on Transmitter, Battery Operation time: 8 hour with rechargeable battery, Range : 100 meters, PLL Synthesized Circuits. Approved Make : OSL/Beyerdynamic/Shure/Sennheiser
403Supply of Wireless Handheld Receiver with Diversity Principle: True Diversity, No. of Channels : 1, Frequency response 20-20 Khz, Frequency Selection: Auto, Modulation : Wideband FM, Attenuation : 0 to 14 Db selectable , LED Display, Range : 100 meters, With RF Shielding and Wireless Handheld Microphone Transmitter with Wireless Bodypack Transmitter with RF Power Output : 30mW, Frequency response: 20 Hz to 20Khz, Volume & Mute Button on Transmitter, Battery Operation time: 8 hour with rechargeable battery, Range : 100 meters, PLL Synthesized Circuits. Approved Make : OSL/Beyerdynamic/Shure/Sennheiser
404Supply of 18\\" Gooseneck Microphone with Electret Condenser, Polar Pattern: Supercardioid, Freq. Response: 20-17 kHz, Max SPL: 140 dB, Working Volatge: 48V DC Phantom Power. And Gooseneck Base with Switch, Frequency Response 20~20,000 Hz, Power Requirement Phantom power 48V or battery power 1.5V*2 (ST-5030i work with 12~48V Phantom power), Current Consumption-Stand-by 2.4mA, Current Consumption-Operating 6.6mA, Switches Microphone selection:ECM MIC unbalanced input, ECM MIC balanced input, Dynamic MIC input Magnetic switch: power on/off, Aprroved Make: DPA/ OSL/ Neumann/ Sennheiser
405Supply of High-performance Handheld Vocal Microphone (cardioid, dynamic) with metal housing & adapted sensitivity for deep vocals. Includes (1) Travel Case (2) Placement Rings & (2) Wind Protectors.. Aprroved Make: DPA/ OSL/ Neumann/ Sennheiser
406Supply of Instrument microphone (supercardioid, hybrid condenser) for drum overheads with 3-pin XLR-M. Includes (1) Mic clip and (1) travel pouch.Aprroved Make: DPA/ OSL/ Neumann/ Sennheiser
407Supply of Mic Stand BigAprroved Make: MyStand/DPA/ OSL/ Neumann/ Sennheiser/Custom
408Supply of 2.5sqmm 2 core speaker cable Approved Make : Krystal/Belden/Sommer/LYNQ
409Supply of 2 core Signal/Microphone cable Approved Make : Krystal/Belden/Sommer/LYNQ
410Supply of 24 pair 33 mtr Snake cable with patch box Approved Make : huja/Hawk/Krystal/LYNQ
411Supply of InterconnectsApproved Make : Nutrik/Amphenol/reputed make
412Supply of 16U Audio rackApproved Make : Valrack/Comrack/Netrack/Reputed Make Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 56689338
AUTHORITY Local Bodies
TENDER VALUE 4.99 Crore
LAST DATE 06-08-2026
Authority
Authority Name Department Of Local Bodies
Work Description Tender for Municipal Council Banswara Construction Of Convention Centre Schem Shyama Prasad Mukharaji
Basic Detail
Tender No MUNICIPAL COUNCIL BANSWARA 10/2026-27/01
Bidding Type Tender
Location
City Banswara
State Rajasthan
Key Dates
Publish Date 28 Jul 2026
Submission Date 06 Aug 2026
Open Date 07 Aug 2026
Finance
Tender Value 4.99 Crore
Tender Fee 5000
EMD 9.98 Lakhs
Exemption Available
Document List
027b9a0e-b19a-41bb-ae8a-ef37ace2851e.html
BOQ_1027632.xls
Tendernotice_1.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Jul 28, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Aug 06, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 6 days
Aug 07, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 7 days

Tender Documents

Download All (ZIP) ↓
html

027b9a0e-b19a-41bb-ae8a-ef37ace2851e.html

xls

BOQ_1027632.xls

pdf

Tendernotice_1.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender