Bids Are invited for Integrated Security Surveillance System Service - Replacement Of Components Of Ibms Systems (Cctv, Acs, Wld And Field Sensors) Of Nbgh Along With 4 Years Of Camc Of The Replaced Components; Replacement Of Components Of Ibms Syste
Tender Overview
Project Description
Bids Are invited for Integrated Security Surveillance System Service - Replacement Of Components Of Ibms Systems (Cctv, Acs, Wld And Field Sensors) Of Nbgh Along With 4 Years Of Camc Of The Replaced Components; Replacement Of Components Of Ibms Systems (Cctv, Acs, Wld An.. - Sensors For Measuring Outside Air Temperature & Rh , Immersion Type Temperature Sensors With Thermowell & Allaccessories For Measuring Temperature Of Chw Temperaturesfor Chillers. , Differential Pressure Switches For Pumps. , Sensors For Measuring Ra Temperature. , Co Sensors For Measuring Co In Basements. , Ambient Air Co2 Sensors For Ac Plant. , Differential Pressure Switch To Monitor The Filter Status. , Differential Pressure Switch To Monitor The Blower Status. , Level Transmitter To Indicate Tank Level Status. , Level Switch To Indicate Tank Level. , Flame Proof Level Sensor For Dg Tanks. , Static Pressure Sensor For Hydrant/Sprinkler System. , Flow Meter For Measuring Water Flow (Line Size According Tohvac Drawings) , Ahu Return Air Co2 Sensors. , Dome Ip Camera , Ptz Camera , Fish Eye Camera , Bullet Camera , Media Converters: Media Converters To Convert Ethernet Mediato Fibre (For Connecting Outdoor Ip Cameras Through Fibrecables. , Iclass Rs10 Read Only Contactless Smart Card Reader, Mifaredesfire Ev1 & Mifare Classic Technologies With Ignallconnectivity , Door Release Modules To Link Acs Locks With Fas Module , Biometric Reader: Store Finger Prints Locally, Inbuilt Reader Andenroller Functionality, Storage For 200 User Templates,Transaction Storage Of 2000, Ip Enabled Or Controller Asrequired, Operating Temperature: -10 Deg C To +50 Deg C,Humidity: 90% Non-Condensing , Egress Switch: Stainless Steel Single Gang Message Plate Withilluminated 2 Button Inscribed Press To Exit, Contact :Momentary Spdt, No/Nc Contact Rating 10 S , Break Glass Unit: Mounting Box As Required, Contact: Dpdtwith 10 Rating, Built In Siren , Single Leaf Electromagnetic Lock With Contact: , Double Leaf Electromagnetic Lock With Contact: , Water Leak Detection Module , Water Leak Detection Cable Sensor As Per Specs. - 50 Mtrs , Sitc Of Water Leak Detection Panel For Controlling The Modulecable Sensor With Tcp/Ip Interface And Bas Compatible As Perspecification Mentioned Including All Accessories Power Supplywith Battery Back Up. , Electronics Hooter With Flasher
BOQ
| Sl. No. | Item Title | Item Description |
| 1 | Sensors for measuring outside air temperature & RH | Sensors for measuring outside air temperature & RH |
| 2 | Immersion type temperature sensors with thermowell & allaccessories for measuring temperature of CHW temperaturesfor Chillers. | Immersion type temperature sensors with thermowell & allaccessories for measuring temperature of CHW temperaturesfor Chillers. |
| 3 | Differential Pressure Switches for Pumps. | Differential Pressure Switches for Pumps. |
| 4 | Sensors for measuring RA temperature. | Sensors for measuring RA temperature. |
| 5 | CO Sensors for measuring CO in Basements. | CO Sensors for measuring CO in Basements. |
| 6 | Ambient air CO2 Sensors for AC Plant. | Ambient air CO2 Sensors for AC Plant. |
| 7 | Differential pressure switch to monitor the filter status. | Differential pressure switch to monitor the filter status. |
| 8 | Differential pressure switch to monitor the blower status. | Differential pressure switch to monitor the blower status. |
| 9 | Level transmitter to indicate tank level status. | Level transmitter to indicate tank level status. |
| 10 | Level Switch to indicate tank level. | Level Switch to indicate tank level. |
| 11 | Flame proof Level sensor for DG Tanks. | Flame proof Level sensor for DG Tanks. |
| 12 | Static pressure sensor for Hydrant/Sprinkler System. | Static pressure sensor for Hydrant/Sprinkler System. |
| 13 | Flow meter for measuring water flow (Line size according toHVAC drawings) | Flow meter for measuring water flow (Line size according toHVAC drawings) |
| 14 | AHU return air CO2 Sensors. | AHU return air CO2 Sensors. |
| 15 | Dome IP Camera | Dome IP Camera |
| 16 | PTZ Camera | PTZ Camera |
| 17 | Fish eye camera | Fish eye camera |
| 18 | Bullet Camera | Bullet Camera |
| 19 | Media Converters: Media Converters to convert Ethernet Mediato Fibre (For Connecting outdoor IP cameras through Fibrecables. | Media Converters: Media Converters to convert Ethernet Mediato Fibre (For Connecting outdoor IP cameras through Fibrecables. |
| 20 | iClass RS10 Read only contactless smart card reader, MIFAREDESFire EV1 & MIFARE Classic technologies with ignallconnectivity | iClass RS10 Read only contactless smart card reader, MIFAREDESFire EV1 & MIFARE Classic technologies with ignallconnectivity |
| 21 | Door release modules to link ACS locks with FAS module | Door release modules to link ACS locks with FAS module |
| 22 | Biometric Reader: Store finger prints locally, Inbuilt Reader andEnroller functionality, Storage for 200 user templates,Transaction storage of 2000, IP enabled or controller asrequired, Operating temperature: -10 deg C to +50 deg C,Humidity: 90% non-condensing | Biometric Reader: Store finger prints locally, Inbuilt Reader andEnroller functionality, Storage for 200 user templates,Transaction storage of 2000, IP enabled or controller asrequired, Operating temperature: -10 deg C to +50 deg C,Humidity: 90% non-condensing |
| 23 | Egress Switch: Stainless Steel single gang message plate withIlluminated 2” button inscribed “Press to Exit”, Contact :Momentary SPDT, NO/NC contact rating 10 Amps | Egress Switch: Stainless Steel single gang message plate withIlluminated 2” button inscribed “Press to Exit”, Contact :Momentary SPDT, NO/NC contact rating 10 Amps |
| 24 | Break Glass Unit: Mounting box as required, Contact: DPDTwith 10Amp rating, Built in siren | Break Glass Unit: Mounting box as required, Contact: DPDTwith 10Amp rating, Built in siren |
| 25 | Single Leaf Electromagnetic Lock with contact: | Single Leaf Electromagnetic Lock with contact: |
| 26 | Double Leaf Electromagnetic Lock with contact: | Double Leaf Electromagnetic Lock with contact: |
| 27 | Water Leak detection module | Water Leak detection module |
| 28 | Water leak detection cable sensor as per Specs. - 50 mtrs | Water leak detection cable sensor as per Specs. - 50 mtrs |
| 29 | SITC of water Leak Detection Panel for Controlling the ModuleCable Sensor with TCP/IP interface and BAS compatible as perspecification mentioned including all accessories Power Supplywith battery back up. | SITC of water Leak Detection Panel for Controlling the ModuleCable Sensor with TCP/IP interface and BAS compatible as perspecification mentioned including all accessories Power Supplywith battery back up. |
| 30 | Electronics Hooter with Flasher | Electronics Hooter with Flasher |
AI Tender Summary
Tender Timeline
Tender Published
Tender notice published.
CompletedBid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 39 daysBid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 39 daysTender Documents
Download All (ZIP) ↓We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender