Defence Government Departments Closing in 17 days TDR #56685125

Bids Are invited for Procurement And Installation Of Ventilation System At Ships Galley Of Ins Angre

Issued by Government Departments · Mumbai, Maharashtra
Tender Value
Ref. Documents
Estimated cost
Bid Submission
17 Aug 2026
17 days left
EMD
1.50 Lakhs
Bank guarantee accepted
Document Fee
Ref. Documents
Non-refundable
Tender Type
Gem

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Mumbai → Maharashtra
EMD Exemption
Available
Quantity
9343

Project Description

Bids Are invited for Procurement And Installation Of Ventilation System At Ships Galley Of Ins Angre Sitc Of 11Tr Double Skin Tfa Fabricated From - Sitc Of 11Tr Double Skin Tfa Fabricated From Outer Skin With Zero Point 60 Mm Thick Precoated Gi Sheet And Plainzero Point 60 Mm Thick Inner Gi Sheet With 25 Mm Thick Injected Puf Insulation With Aluminum Extruded Framework Having Thermal Break Profile With Internal Coving Complete With Mixing Box Backward Centrifugalfan Copper Cooling Coil And Filter Section Complete With Pre Filters Designed To Remove Particles Down To10 Microns With An Efficiency Of 90 Percent On Ashrae Std 52 To 56 And 90 Percent On Bs 2831 Test Dust No 2 Juniorfilter In Crca Construction Duly Powder Coated The Filter Shall Have 3 Stage Of Non Woven Syntheticpolymedia Sandwitched Between 2 Layers Of Hdpe Mesh Duly Epoxy Sealed At The Ends , Sitc Of Bluestar Outdoor 11 Tr Single Crust - Sitc Of Bluestar Outdoor 11 Tr Single Circuit R410 Compatiable To The Above Tfa , Supply Installation Balancing And Commissioning Of Factory - Supply Installation Balancing And Commissioning Of Factory Fabricated Gss Sheet Metal Rectangular Asper Smacna Standards And Specifications Complete With Neoprene Rubber Gaskets Elbows Splittervanes Hangers Etc As Per Approved Drawings And Specifications All Supports Should Be Made Ofgalvanised Steel Angle With Drilled Holes And Gi Threaded Rods With Check Nuts And Washers Of Hilti Withsupport From Roof , Supplying And Fixing Of 25Mm Thickness Xlpe - Supplying And Fixing Of 25Mm Thickness Xlpe With Aluminium Foil Class O Insulation On Duct Afterapplying Manufacturers Recommended Adhesive Density Of The Material Shall Be 25 To 30 Kg Per M3 Theinsulation Material Shall Be Fire Rated The Joints Shall Be Sealed With 50 Mm Wide And 3 Mm Thick Selfadhesive Tape Insulation Complete As Per Specifications And As Required , Supply Fabrication And Fixing Of 11 By 8 Inch And 5 By 8 Inch - Supply Fabrication And Fixing Of 1 1 By 8 Inch And 5 By 8 Inch Sizes Copper Piping Along With Inline Fittings Insulationsleeve And Support , Supply And Laying Of Frls Type Copper Power - Supply And Laying Of Frls Type Copper Power Cable 4 Core 4 Sqmm Between Electrical Panel Iud And Odus , Supply Installation And Balancing Of Extruded - Supply Installation And Balancing Of Extruded Aluminium Construction Linear Grill With Opposed Bladecollar D Ers For Supply Or Return Air The Grill Shall Be Powder Coated Off White With Standard Finish Ral9016 And Installed As Per Approved Shop Drawings And Specifications , Supply Fabrication And Installation Of Tfa - Supply Fabrication Installation Of Tfa Ms Platform With Ms C Channel Ms Chukker Plate And Fixing Withanchor Fastener , Supply Fabrication And Installation Of Odu - Supply Fabrication And Installation Of Odu Ms Platform With Ms L Angle And Fixing With Anchor Fastener , Supply Installation And Testing Of Flexible Connections - Supply Installation And Testing Of Flexible Connections Shall Be Constructed Of Fire Resistant Doublecanvas Fire Retardant Fabric Made Up Of Vinyl Polyster Fabric With Minimum 150 Mm Secured Togalvanized Sheet Metal On Either Side , Supply And Fixing Industrial Grade Upvc - Supply Fixing Industrial Grade Upvc Drain Pipe With 9 Mm Thick Nitrile Rubber Insulationupvc Pipe , Supply And Fixing Of Powder Coated Ms Enclosure - Supply And Fixing Of Powder Coated Ms Enclosure Ip Rated Electrical Control Panelip54 By Ip55 Compatible With Building Management Systems Bms For Centralized Monitoring Andcontrol Equipped With Mcb Mccb Overload Relays Phase Failure Protection And Short Circuitprotection , Installation And Commissioning Of Complete - Installation And Commisssioning Of Complete System Along With Flushing Vaccumising And Gas Chargingwith Suitable Refrigerant If Required , Sitc Of 25Tr Dx Double Skin Air Handling - Sitc Of 25Tr Double Skin Air Handling Units Fabricated From Outer Skin With Zero Point 60 Mm Thick Precoated Gisheet And Plain Zero Point 60 Mm Thick Inner G I Sheet With 25 Mm Thick Injected Puf Insulation With Aluminumextruded Frame Work Having Thermal Break Profile With Internal Coving Complete With Backwardcentrifugal Fan Copper Cooling Coil And Filter Section Complete With Pre Filters Designed To Removeparticles Down To 10 Microns With An Efficiency Of 90 Percent On Ashrae Std 52 To 56 And 90 Percent On Bs 2831 Testdust No 2 Junior Filter In Crca Construction Duly Powder Coated The Filter Shall Have 3 Stage Of Nonwoven Synthetic Polymedia Sandwitched Between 2 Layers Of Hdpe Mesh Duly Epoxy Sealed At The Ends , Sitc Of Bluestar Outdoor 8.5 Tr - Sitc Of Bluestar Outdoor 8 Point 5 Tr Single Circuit R410 Compatiable To The Above Ahu , Supply Installation Balancing And Commissioning Of Factory Fabricated - Supply Installation Balancing And Commissioning Of Factory Fabricated Gss Sheet Metal Rectangular Asper Smacna Standards And Specifications Complete With Neoprene Rubber Gaskets Elbows Splittervanes Hangers Etc As Per Approved Drawings And Specifications All Supports Should Be Made Ofgalvanised Steel Angle With Drilled Holes And Gi Threaded Rods With Check Nuts And Washers Of Hilti Withsupport From Roof , Supply And Fixing Of 25Mm Thickness Xlpe - Supplying And Fixing Of 25Mm Thickness Xlpe With Aluminium Foil Class O Insulation On Duct Afterapplying Manufacturers Recommended Adhesive Density Of The Material Shall Be 25 To 30 Kg Per M3 Theinsulation Material Shall Be Fire Rated The Joints Shall Be Sealed With 50 Mm Wide And 3 Mm Thick Selfadhesive Tape Insulation Complete As Per Specifications And As Required , Supply Fabrication And Fixing Of 11 By 8 Inch And 5 By 8 Inch Sizes - Supply Fabrication And Fixing Of 1 1 By 8 Inch And 5 By 8 Inch Sizes Copper Piping Along With Inline Fittings Insulationsleeve And Support , Supply And Laying Of Frls Type Copper Power - Supply And Laying Of Frls Type Copper Power Cable 4 Core 4 Sqmm Between Electrical Panel Iud Odus , Supply Installation And Balancing Of Extruded - Supply Installation And Balancing Of Extruded Aluminium Construction Linear Grill With Opposed Bladecollar D Ers For Supply Return Air The Grill Shall Be Powder Coated Off White With Standard Finish Ral9016 And Installed As Per Approved Shop Drawings And Specifications , Supply Fabrications And Installation Of Ahu - Supply Fabrication And Installation Of Ahu Ms Platform With Ms C Channel Ms Chukker Plate And Fixing Withanchor Fastener , Supply Fabrication And Installation Of Odu - Supply Fabrication And Installation Of Odu Ms Platform With Ms L Angle And Fixing With Anchor Fastener , Supply Installation And Testing Of Flexible Connections - Supply Installation And Testing Of Flexible Connections Shall Be Constructed Of Fire Resistant Doublecanvas Fire Retardant Fabric Made Up Of Vinyl Polyster Fabric With Minimum 150 Mm Secured Togalvanized Sheet Metal On Either Side , Supply And Fixing Industrial Grade Upvc - Supply And Fixing Industrial Grade Upvc Drain Pipe With 9 Mm Thick Nitrile Rubber Insulationupvc Pipe , Supply And Fixing Of Powder Coated Ms Enclosure - Supply And Fixing Of Powder Coated Ms Enclosure Ip Rated Electrical Control Panelip54 Or Ip55 Compatible With Building Management Systems Bms For Centralized Monitoring Andcontrol Equipped With Mcb Mccb Overload Relays Phase Failure Protection And Short Circuitprotection , Installation And Commissioning Of Complete System - Installation And Commissioning Of Complete System Along With Flushing Vaccum And Gas Chargingwith Suitable Refrigerant If Required

BOQ

Sl. No. Item TitleItem Description
1SITC of 11TR Double skin TFA fabricated fromSITC of 11TR Double skin TFA fabricated from outer skin with Zero Point 60 mm thick precoated GI sheet and plainZero Point 60 mm thick inner GI sheet with 25 mm thick injected puf insulation with Aluminum extruded framework having Thermal break profile with internal coving complete with mixing box backward centrifugalfan copper cooling coil and Filter Section complete with pre filters designed to remove particles down to10 Microns with an efficiency of 90 percent on ASHRAE STD 52 to 56 and 90 percent on BS 2831 Test Dust No 2 JuniorFilter in CRCA construction duly powder coated The filter shall have 3 stage of Non Woven syntheticpolymedia sandwitched between 2 layers of HDPE mesh duly epoxy sealed at the ends
2SITC of bluestar outdoor 11 TR single crustSITC Of Bluestar Outdoor 11 TR Single Circuit R410 compatiable to the above TFA
3Supply installation balancing and commissioning of factorySupply installation balancing and commissioning of factory fabricated GSS sheet metal rectangular asper SMACNA standards and specifications complete with neoprene rubber gaskets elbows splittervanes hangers etc as per approved drawings and specifications All supports should be made ofgalvanised steel angle with drilled holes and GI threaded rods with check nuts and washers of Hilti withsupport from roof
4Supplying and fixing of 25mm thickness XLPESupplying and fixing of 25mm thickness XLPE with Aluminium foil Class O insulation on duct afterapplying Manufacturers recommended adhesive Density of the material shall be 25 to 30 Kg per m3 Theinsulation material shall be fire rated The joints shall be sealed with 50 mm wide and 3 mm thick selfadhesive tape insulation complete as per specifications and as required
5Supply fabrication and fixing of 11 by 8 inch and 5 by 8 inchSupply fabrication and fixing of 1 1 by 8 inch and 5 by 8 inch sizes copper piping along with inline fittings insulationsleeve and support
6Supply and laying of FRLS type copper powerSupply and laying of FRLS type Copper power cable 4 core 4 Sqmm between electrical panel IUD and ODUs
7Supply installation and balancing of extrudedSupply installation and balancing of Extruded Aluminium construction linear grill with Opposed bladecollar dampers for supply or return air The grill shall be powder coated off white with Standard finish RAL9016 and installed as per approved shop drawings and specifications
8Supply fabrication and installation of TFASupply fabrication installation of TFA Ms platform with Ms C channel Ms chukker plate and fixing withanchor fastener
9Supply fabrication and installation of ODUSupply fabrication and installation of ODU Ms platform with Ms L Angle and fixing with anchor fastener
10Supply installation and testing of flexible connectionsSupply Installation and testing of Flexible connections shall be constructed of fire resistant doublecanvas fire retardant fabric made up of vinyl polyster fabric with minimum 150 mm secured togalvanized sheet metal on either side
11Supply and fixing industrial grade UPVCSupply Fixing industrial grade uPVC drain pipe with 9 mm thick nitrile rubber insulationuPVC Pipe
12Supply and fixing of powder coated Ms enclosureSupply and Fixing of Powder coated MS enclosure IP rated electrical control panelIP54 by IP55 Compatible with Building Management Systems BMS for centralized monitoring andcontrol Equipped with MCB MCCB overload relays phase failure protection and short circuitProtection
13Installation and commissioning of completeInstallation and commisssioning of complete system along with flushing vaccumising and gas chargingwith suitable refrigerant if required
14SITC of 25TR DX double skin air handlingSITC of 25TR Double skin air handling units fabricated from outer skin with zero point 60 mm thick precoated GIsheet and plain zero point 60 mm thick inner G I sheet with 25 mm thick injected puf insulation with Aluminumextruded frame work having Thermal break profile with internal coving complete with backwardcentrifugal fan copper cooling coil and Filter Section complete with pre filters designed to removeparticles down to 10 Microns with an efficiency of 90 percent on ASHRAE STD 52 to 56 and 90 percent on BS 2831 TestDust No 2 Junior Filter in CRCA construction duly powder coated The filter shall have 3 stage of NonWoven synthetic polymedia sandwitched between 2 layers of HDPE mesh duly epoxy sealed at the ends
15SITC of bluestar outdoor 8.5 TRSITC Of Bluestar Outdoor 8 point 5 TR Single Circuit R410 compatiable to the above AHU
16Supply installation balancing and commissioning of factory fabricatedSupply installation balancing and commissioning of factory fabricated GSS sheet metal rectangular asper SMACNA standards and specifications complete with neoprene rubber gaskets elbows splittervanes hangers etc as per approved drawings and specifications All supports should be made ofgalvanised steel angle with drilled holes and GI threaded rods with check nuts and washers of Hilti withsupport from roof
17Supply and fixing of 25mm thickness XLPESupplying and fixing of 25mm thickness XLPE with Aluminium foil Class O insulation on duct afterapplying Manufacturers recommended adhesive Density of the material shall be 25 to 30 Kg per m3 Theinsulation material shall be fire rated The joints shall be sealed with 50 mm wide and 3 mm thick selfadhesive tape insulation complete as per specifications and as required
18Supply fabrication and fixing of 11 by 8 inch and 5 by 8 inch sizesSupply fabrication and fixing of 1 1 by 8 inch and 5 by 8 inch sizes copper piping along with inline fittings insulationsleeve and support
19Supply and laying of FRLS type copper powerSupply and laying of FRLS type Copper power cable 4 core 4 Sqmm between electrical panel IUD ODUs
20Supply installation and balancing of extrudedSupply installation and balancing of Extruded Aluminium construction linear grill with Opposed bladecollar dampers for supply return air The grill shall be powder coated off white with Standard finish RAL9016 and installed as per approved shop drawings and specifications
21Supply fabrications and installation of AHUSupply fabrication and installation of AHU Ms platform with Ms C channel Ms chukker plate and fixing withanchor fastener
22Supply fabrication and installation of ODUSupply fabrication and installation of ODU Ms platform with Ms L Angle and fixing with anchor fastener
23Supply installation and testing of flexible connectionsSupply Installation and testing of Flexible connections shall be constructed of fire resistant doublecanvas fire retardant fabric made up of vinyl polyster fabric with minimum 150 mm secured togalvanized sheet metal on either side
24Supply and fixing industrial grade UPVCSupply and Fixing industrial grade uPVC drain pipe with 9 mm thick nitrile rubber insulationuPVC Pipe
25Supply and fixing of powder coated Ms enclosureSupply and Fixing of Powder coated MS enclosure IP rated electrical control panelIP54 or IP55 Compatible with Building Management Systems BMS for centralized monitoring andcontrol Equipped with MCB MCCB overload relays phase failure protection and short circuitprotection
26Installation and commissioning of complete systemInstallation and commissioning of complete system along with flushing vaccum and gas chargingwith suitable refrigerant if required

AI Tender Summary

OUR REF NO 56685125
AUTHORITY Government Departments
TENDER VALUE Ref. Documents
LAST DATE 17-08-2026
Authority
Authority Name Indian Navy
Work Description Bids Are invited for Procurement And Installation Of Ventilation System At Ships Galley Of Ins Angre Sitc Of 11Tr Double Skin Tfa Fabricated From - Sitc Of 11Tr Double Skin Tfa Fabricated From Outer Skin With Zero Point 60 Mm Thick Precoated Gi Sheet And Plainzero Point 60 Mm Thick Inner Gi Sheet With 25 Mm Thick Injected Puf Insulation With Aluminum Extruded Framework Having Thermal Break Profile With Internal Coving Complete With Mixing Box Backward Centrifugalfan Copper Cooling Coil And Filter Section Complete With Pre Filters Designed To Remove Particles Down To10 Microns With An Efficiency Of 90 Percent On Ashrae Std 52 To 56 And 90 Percent On Bs 2831 Test Dust No 2 Juniorfilter In Crca Construction Duly Powder Coated The Filter Shall Have 3 Stage Of Non Woven Syntheticpolymedia Sandwitched Between 2 Layers Of Hdpe Mesh Duly Epoxy Sealed At The Ends , Sitc Of Bluestar Outdoor 11 Tr Single Crust - Sitc Of Bluestar Outdoor 11 Tr Single Circuit R410 Compatiable To The Above Tfa , Supply Installation Balancing And Commissioning Of Factory - Supply Installation Balancing And Commissioning Of Factory Fabricated Gss Sheet Metal Rectangular Asper Smacna Standards And Specifications Complete With Neoprene Rubber Gaskets Elbows Splittervanes Hangers Etc As Per Approved Drawings And Specifications All Supports Should Be Made Ofgalvanised Steel Angle With Drilled Holes And Gi Threaded Rods With Check Nuts And Washers Of Hilti Withsupport From Roof , Supplying And Fixing Of 25Mm Thickness Xlpe - Supplying And Fixing Of 25Mm Thickness Xlpe With Aluminium Foil Class O Insulation On Duct Afterapplying Manufacturers Recommended Adhesive Density Of The Material Shall Be 25 To 30 Kg Per M3 Theinsulation Material Shall Be Fire Rated The Joints Shall Be Sealed With 50 Mm Wide And 3 Mm Thick Selfadhesive Tape Insulation Complete As Per Specifications And As Required , Supply Fabrication And Fixing Of 11 By 8 Inch And 5 By 8 Inch - Supply Fabrication And Fixing Of 1 1 By 8 Inch And 5 By 8 Inch Sizes Copper Piping Along With Inline Fittings Insulationsleeve And Support , Supply And Laying Of Frls Type Copper Power - Supply And Laying Of Frls Type Copper Power Cable 4 Core 4 Sqmm Between Electrical Panel Iud And Odus , Supply Installation And Balancing Of Extruded - Supply Installation And Balancing Of Extruded Aluminium Construction Linear Grill With Opposed Bladecollar D Ers For Supply Or Return Air The Grill Shall Be Powder Coated Off White With Standard Finish Ral9016 And Installed As Per Approved Shop Drawings And Specifications , Supply Fabrication And Installation Of Tfa - Supply Fabrication Installation Of Tfa Ms Platform With Ms C Channel Ms Chukker Plate And Fixing Withanchor Fastener , Supply Fabrication And Installation Of Odu - Supply Fabrication And Installation Of Odu Ms Platform With Ms L Angle And Fixing With Anchor Fastener , Supply Installation And Testing Of Flexible Connections - Supply Installation And Testing Of Flexible Connections Shall Be Constructed Of Fire Resistant Doublecanvas Fire Retardant Fabric Made Up Of Vinyl Polyster Fabric With Minimum 150 Mm Secured Togalvanized Sheet Metal On Either Side , Supply And Fixing Industrial Grade Upvc - Supply Fixing Industrial Grade Upvc Drain Pipe With 9 Mm Thick Nitrile Rubber Insulationupvc Pipe , Supply And Fixing Of Powder Coated Ms Enclosure - Supply And Fixing Of Powder Coated Ms Enclosure Ip Rated Electrical Control Panelip54 By Ip55 Compatible With Building Management Systems Bms For Centralized Monitoring Andcontrol Equipped With Mcb Mccb Overload Relays Phase Failure Protection And Short Circuitprotection , Installation And Commissioning Of Complete - Installation And Commisssioning Of Complete System Along With Flushing Vaccumising And Gas Chargingwith Suitable Refrigerant If Required , Sitc Of 25Tr Dx Double Skin Air Handling - Sitc Of 25Tr Double Skin Air Handling Units Fabricated From Outer Skin With Zero Point 60 Mm Thick Precoated Gisheet And Plain Zero Point 60 Mm Thick Inner G I Sheet With 25 Mm Thick Injected Puf Insulation With Aluminumextruded Frame Work Having Thermal Break Profile With Internal Coving Complete With Backwardcentrifugal Fan Copper Cooling Coil And Filter Section Complete With Pre Filters Designed To Removeparticles Down To 10 Microns With An Efficiency Of 90 Percent On Ashrae Std 52 To 56 And 90 Percent On Bs 2831 Testdust No 2 Junior Filter In Crca Construction Duly Powder Coated The Filter Shall Have 3 Stage Of Nonwoven Synthetic Polymedia Sandwitched Between 2 Layers Of Hdpe Mesh Duly Epoxy Sealed At The Ends , Sitc Of Bluestar Outdoor 8.5 Tr - Sitc Of Bluestar Outdoor 8 Point 5 Tr Single Circuit R410 Compatiable To The Above Ahu , Supply Installation Balancing And Commissioning Of Factory Fabricated - Supply Installation Balancing And Commissioning Of Factory Fabricated Gss Sheet Metal Rectangular Asper Smacna Standards And Specifications Complete With Neoprene Rubber Gaskets Elbows Splittervanes Hangers Etc As Per Approved Drawings And Specifications All Supports Should Be Made Ofgalvanised Steel Angle With Drilled Holes And Gi Threaded Rods With Check Nuts And Washers Of Hilti Withsupport From Roof , Supply And Fixing Of 25Mm Thickness Xlpe - Supplying And Fixing Of 25Mm Thickness Xlpe With Aluminium Foil Class O Insulation On Duct Afterapplying Manufacturers Recommended Adhesive Density Of The Material Shall Be 25 To 30 Kg Per M3 Theinsulation Material Shall Be Fire Rated The Joints Shall Be Sealed With 50 Mm Wide And 3 Mm Thick Selfadhesive Tape Insulation Complete As Per Specifications And As Required , Supply Fabrication And Fixing Of 11 By 8 Inch And 5 By 8 Inch Sizes - Supply Fabrication And Fixing Of 1 1 By 8 Inch And 5 By 8 Inch Sizes Copper Piping Along With Inline Fittings Insulationsleeve And Support , Supply And Laying Of Frls Type Copper Power - Supply And Laying Of Frls Type Copper Power Cable 4 Core 4 Sqmm Between Electrical Panel Iud Odus , Supply Installation And Balancing Of Extruded - Supply Installation And Balancing Of Extruded Aluminium Construction Linear Grill With Opposed Bladecollar D Ers For Supply Return Air The Grill Shall Be Powder Coated Off White With Standard Finish Ral9016 And Installed As Per Approved Shop Drawings And Specifications , Supply Fabrications And Installation Of Ahu - Supply Fabrication And Installation Of Ahu Ms Platform With Ms C Channel Ms Chukker Plate And Fixing Withanchor Fastener , Supply Fabrication And Installation Of Odu - Supply Fabrication And Installation Of Odu Ms Platform With Ms L Angle And Fixing With Anchor Fastener , Supply Installation And Testing Of Flexible Connections - Supply Installation And Testing Of Flexible Connections Shall Be Constructed Of Fire Resistant Doublecanvas Fire Retardant Fabric Made Up Of Vinyl Polyster Fabric With Minimum 150 Mm Secured Togalvanized Sheet Metal On Either Side , Supply And Fixing Industrial Grade Upvc - Supply And Fixing Industrial Grade Upvc Drain Pipe With 9 Mm Thick Nitrile Rubber Insulationupvc Pipe , Supply And Fixing Of Powder Coated Ms Enclosure - Supply And Fixing Of Powder Coated Ms Enclosure Ip Rated Electrical Control Panelip54 Or Ip55 Compatible With Building Management Systems Bms For Centralized Monitoring Andcontrol Equipped With Mcb Mccb Overload Relays Phase Failure Protection And Short Circuitprotection , Installation And Commissioning Of Complete System - Installation And Commissioning Of Complete System Along With Flushing Vaccum And Gas Chargingwith Suitable Refrigerant If Required
Basic Detail
Tender No GEM/2026/B/7826961
Bidding Type Tender
Location
City Mumbai
State Maharashtra
Key Dates
Publish Date 27 Jul 2026
Submission Date 17 Aug 2026
Open Date 17 Aug 2026
Finance
Tender Value Ref. Documents
Tender Fee Ref. Documents
EMD 1.50 Lakhs
Exemption Available
Document List
69518527-a679-4190-99ec-40b15db78f69.pdf
9652321_Boq_1.xlsx
attt_28839398-9d42-44d0-86f81784804548044_Angre.dlogo.pdf
sow_for_galley_ventilation-1_2026-07-23-16-23-20_62b1cece54f8a27fa5cd24ed4bab5bd9.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Jul 27, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Aug 17, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 17 days
Aug 17, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 17 days

Tender Documents

Download All (ZIP) ↓
pdf

69518527-a679-4190-99ec-40b15db78f69.pdf

xlsx

9652321_Boq_1.xlsx

attt_28839398-9d42-44d0-86f81784804548044_Angre.dlogo.pdf

pdf

sow_for_galley_ventilation-1_2026-07-23-16-23-20_62b1cece54f8a27fa5cd24ed4bab5bd9.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail
Loading tenders