Housing Urban and Rular Development Government Departments Closing in 14 days TDR #56684344

Tender For Construction Of Phc Building At Chushul. ( Under Vvp )

Issued by Government Departments · Leh, Ladakh
Tender Value
3.75 Crore
Estimated cost
Bid Submission
11 Aug 2026
14 days left
EMD
7.50 Lakhs
Bank guarantee accepted
Document Fee
3751
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Leh → Ladakh
EMD Exemption
Not Available
Quantity
Not Available

Project Description

Tender for Construction Of Phc Building At Chushul. ( Under Vvp )

BOQ

Name of Work:- Construction of PHC Building at Chushul. ( Under VVP )
Sl. No. Item Description
1Earth work in excavation by mechanical means (Hydraulic excavator) over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead upto 50 m and lift upto 1.5 m, as directed by Engineer-in-charge. All kinds of soil
2Dumping stone in horizontal level including cost of stone and complete job.
3Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level :1:4:8 (1 cement : 4 manufactured sand derived from Recycled Concrete Aggregate (RCA) : 8 graded stone aggregate 40 mm nominal size RecycledAggregate (RA)
4Random rubble masonry with hard stone in foundation and plinth includinglevelling up with cement concrete 1:6:12 (1 cement : 6 coarse sand : 12 gradedstone aggregate 20 mm nominal size) upto plinth level with : Cement mortar 1:6 (1 cement : 6 coarse sand)
5Filling available excavated earth (excluding rock) in trenches, plinth, sides offoundations etc. in layers not exceeding 20cm in depth, consolidating eachdeposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m.
6Cement concrete flooring 1:2:4 (1 cement : 2 coarse sand : 4 graded stoneaggregate) finished with a floating coat of neat cement including cement slurry and curing complete, but excluding the cost of nosing of steps etc. complete 50 mm thick with 20 mm nominal size stone aggregate
7Reinforced cement concrete work in walls (any thickness), including attachedpilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers,abutments, posts and struts etc. above plinth level up to floor five level,excluding cost of centering, shuttering, finishing and reinforcement :1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) : 3 graded stone aggregate 20 mmnominal size)
8Reinforced cement concrete work in beams, suspended floors, roofs havingslope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement, with 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) : 3 graded stone aggregate 20 mm nominal size).
9Steel reinforcement for R.C.C. work including straightening, cutting, bending,placing in position and binding all complete upto plinth level.Thermo-Mechanically Treated bars of grade Fe-500D or more.
10Centering and shuttering including strutting, propping etc. and removal of form forSuspended floors, roofs, landings, balconies and access platform
11Foundations, footings, bases of columns, etc. for mass concrete
12Lintels, beams, plinth beams, girders, bressumers and cantilevers
13Columns, Pillars, Piers, Abutments, Posts and Struts
14Providing wood work in frames of doors, windows, clerestory windows and otherframes, wrought framed and fixed in position with hold fast lugs or with dashfasteners of required dia & length (hold fast lugs or dash fastener shall be paidfor separately).Second class Kail wood
15Providing and fixing glazed shutters for doors, windows and clerestory windowsusing 4 mm thick float glass panes, including ISI marked M.S. pressed butt hinges bright finished of required size with necessary screws.Kiln seasoned selected planks of sheesham wood 35 mm thick
16Providing and fixing ISI marked flush door shutters conforming to IS : 2202 (Part I) decorative type, core of block board construction with frame of 1st class hardwood and well matched teak 3 ply veneering with vertical grains or cross bandsand face veneers on both faces of shutters. 35 mm thick including ISI marked Stainless Steel butt hinges with necessary screws
17French spirit polishing : Two or more coats on new works including a coat of wood filler
18Providing and fixing factory made uPVC white colour casement/casement cumfixed glazed windowscomprising of uPVC multi-chambered frame, sash andmullion (where ever required) extruded profilesduly reinforced with 1.60 ± 0.2mm thick galvanized mild steel section made from roll forming processofrequired length (shape & size according to uPVC profile), uPVC extruded glazing beads of appropriatedimension, EPDM gasket, stainless steel (SS 304 grade) friction hinges, zinc alloy (white powder coated)casement handles, G.I fasteners 100 x 8 mm size for fixing frame to finished wall, plastic packers, plasticcaps and necessary stainless steel screws etc. Profile of frame & sash shall be mitred cut and fusionwelded at all corners, mullion (if required) shall be also fusion welded including drilling of holes for fixinghardware's and drainage of water etc. After fixing frame the gap between frame and adjacent finished wallshall be filled with weather proof silicon sealant over backer rod of required size and of approved quality,all complete as per approved drawing & direction of Engineer-in-Charge.(Single / double glass panes andsilicon sealant shall be paid separately). Variation in profile dimension in higher side shall be acceptedbut no extra payment on this account shall be made.For uPVC frame, sash and mullion extruded profiles minus 5% tolerance indimension i.e. in depth& width of profile shall be acceptable.uPVC profile should be tested by BSI(UK) & SKZ(Germany) @25000 weathering hoursCasement window single panel with S.S. friction hinges (300 x 19 x 1.9 mm), made of (small series) frame 47 x 50 mm & sash 47 x 68 mm both having wall thickness of 1.9 ± 0.2 mm and single glass pane glazing bead of appropriate dimension. (Area of window upto 0.75 sqm.)
19Providing and fixing DGU ( WITH <0.25 SHGC nad > 0.35 VLT glazing in UVT window, ventilator shutter and partition etc with proper sealing as per norms etc complete as per the architectural drawing and the directions of engineer in charged Toughened DGU glass panes of 5.0mm thickness SAINT GOBIN/ ASHI INDIA .
20Providing and fixing aluminium work for doors, windows, ventilators andpartitions with extruded built up standard tubular sections/ appropriate Zsections and other sections of approved make conforming to IS: 733 and IS : 1285, fixed with rawl plugs and screws or with fixing clips, or with expansion hold fasteners including necessary filling up of gaps at junctions, at top, bottom and sides with required PVC/neoprene felt etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / panelling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge. (Glazing and panelling to be paid for separately): For fixed portion. Anodised aluminium (anodised transparent or dyed to required shade according to,minimum anodic coating of grade AC 15)
21Providing and fixing glazing in aluminium door, window, ventilator shutters andpartitions etc. with EPDM rubber / neoprene gasket etc. complete as per thearchitectural drawings and the directions of engineer-in-charge . (Cost ofaluminium snap beading shall be paid in basic item):With float glass panes of 4.0 mm thickness (weight not less than 10kg/sqm)
22Providing and fixing 12mm thick prelaminated particle board flat pressed threelayer or graded wood particle board conforming to IS: 12823 Grade 1 Type II inpanelling fixed in aluminium doors, windows shutters and partition frames withC.P. brass / stainless steel screws etc. complete as per architectural drawings and directions of engineer-in-charge.Pre-laminated particle board with decorative lamination on one side andbalancing lamination on other side.
23Providing and fixing ISI marked oxidised M.S. tower bolt black finish, (Barrel type) with necessary screws etc. complete :200x10 mm
24100X10mm
25Providing and fixing ISI marked oxidised M.S. sliding door bolts with nuts andscrews etc. complete : 300x16 mm
26Providing and fixing ISI marked oxidised M.S. handles conforming to IS:4992 with necessary screws etc.complete : 125 mm
27Providing and fixing ISI marked oxidised M.S. handles conforming to IS:4992 with necessary screws etc.complete :100 mm
28Providing and fixing aluminium tower bolts, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868 ) transparent or dyed to required colour or shade, with necessary screws etc.complete :250x10 mm
29Providing and fixing aluminium handles, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade, with necessary screws etc. complete :100 mm
30Providing and fixing Ist quality ceramic glazed wall tiles conforming to IS: 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineerin- Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm, including pointing in white cement mixed with pigment of matching shade complete.
31Providing & fixing White vitreous china water closet squatting pan (Indian type)along with \\"S\\" or \\"P\\" trap including dismantling of old WC seat and \\"S\\" or \\"P\\" trap at site complete with all operations including all necessary materials, labour and disposal of dismantled material i/c malba, all complete as per the direction of Engineer-in charge. Long pattern W.C Pan of size 580x440 mm
32Providing and fixing white vitreous china pedestal type (European type/ washdown type) water closet pan.
33Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps,32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require :White Vitreous China Wash basin size 630x450 mm with a pair of 15 mm C.P.brass pillar taps.
34Providing and fixing mirror of superior glass (of approved quality) and of required shape and size with plastic moulded frame of approved make and shade with 6 mm thick hard board backing :Rectangular shape 1500x450 mm
35Providing and fixing toilet paper holder :Vitreous china
36Providing and fixing PTMT soap Dish Holder having length of 138mm, breadth102mm, height of 75mm with concealed fitting arrangements weighing not lessthan 106 gms.
37Providing and fixing flow trap of PVC.
38Providing and fixing soil , waste and vent pipes 100mm dia PVC
3975mm dia PVC
40Providing and fixing 3 layer PP-R (Poly propylene Random copolymer) pipes SDR7.4 U V stabilized & anti -microbial fusion welded, having thermal stability for hot& cold water supply including all PP - R plain & brass threaded polypropylenerandom fittings i/c fixing the pipe with clamps at 1.00 m spacing. This includestesting of joints complete as per direction of Engineer in Charge. (Internal workexposed on wall) PN - 16 Pipe, 25mm OD (SDR-7.4)
41Providing and fixing 3 layer PP-R (Poly propylene Random copolymer) pipes SDR7.4 U V stabilized & anti - microbial fusion welded, having thermal stability for hot& cold water supply including all PP-R plain & brass threaded polypropylenerandom fittings i/c trenching .refilling & testing of joints complete as per directionof Engineer in Charge. (External work) PN - 16 Pipe, 32 mm OD (SDR-7.4)
42PN-16 Pipe, 40 mm OD
43Providing and fixing 15mm nominal bore of standard back type C.P brass close hole basin mixer pillar tap of approved quality and make weighing not less than 1.970 kg.
44Providing and fixing ball valve for basin mixer and geyser point of appeoved quality as per direction of engineer in-charge 15mm niminal bore.
45Providing & fixing stabilized mud concrete solid blocks (adobe) with 3% cement,masonry up to floor five level including hoisting and setting in position in cementmortar 1:6 using approved quality mud with carriage of material complete.
46Providing & fixing upto floor five level precast cement concrete solid blocks includinghoisting and setting in position in cement mortar 1:3 (1cement:3 coarse sand), cost ofrequired centring, shuttering and curing complete 1:3:6 (1 cement : 3 coarse sand : 6 graded crushed stone aggregate 20 mm nominalsize)
47Providing and fixing 50 mm thick extruded polystyrene rigid insulation board of required size between cavity wall, complying with ISO 4898:2008 & ASTM C 578-08b - type VI, having thermal conductivity of 0.0289 W/m K as per ASTM C 578 (measured as per IS 3346), compressive strength of > 350kPa listed as per ASTM D 1621, density of 34-36 kg/m³ as per ASTM D 1622, water absorptions <1% by volume as per ASTM D 2842, oxygen index of 24.1 to 28.1 listed as per ASTMD 2863, cell size 0.4 mm of dia (max) as per ASTM D 3576. Fire retardant property as per DIN 4102, Part 1 of class B2 and as per ASTM E84 classA, fixed with suitable water based adhesive and fastener, complete in all respect as per the direction of Engineer- in-Charge
4815mm Cement plaster on the rough side of single or half brick wall of mix:1 : 4 ( 1 cement : 4 fine sand)
49Distempering with oil bound washable distemper of approved brand and manufacture to give an even shade on New work (two or more coats) over and including priming coat with water thinnable cement primer
50Finishing walls with water proofing cement paint of required shade onNew work (two or more coats applied @ 3.84 kg/10sqm)
51Providing & fixing false ceiling at all heights with GRG (Glass Fibre Reinforced Gypsum) false ceiling tiles of Size 595x595 mm of approved texture, design and patterns having moisture content less than 2%, humidity resistance of 99%, NRC0.50 to 0.75 as per IS 8225:1987, Non combustible as per BS 476 (part 4)-1970 and light reflectance of 85% (minimum) to be laid in true horizontal level suspended on inter-lockingmetal T-Grid of hot dipped galvanised iron section of 0.33mm thick (galvanized @ 120 grams per sqm including both sides) comprising of main-T runners of size 15x32 mm of length 3000 mm, cross - T of size 15x32 mm of length 1200 mm and secondary intermediate cross-T of size 15x32 mm of length 600mm to form grid module of size 600 x 600 mm, suspended from ceiling using galvanised mild steel items(galvanizing @ 80 grams per sqm) i.e. 50 mm long, 8 mm outer diameter M-6 dash fasteners, 6 mm dia fully threaded hanger rod upto 1000 mm length and L-shape level adjuster of size 85x25x2 mm. Galvanised iron perimeter wall angle of size 24x24x0.40 mm of length 3000 mm to be fixed on periphery wall / partition with the help of plastic rawl plugs at450 mm center to center and 40 mm long dry wall wood screws. The work shall be carried out as per specifications, drawing and as per directions of the Engineer-in-Charge. With semi perforated 12 mm thick micro tegular edged GRG false ceiling tiles.
52Providing and fixing 12 mm thick pre-laminated flooring of approved brandas per direction of engineer incharge, complete job AC-4 including carriage.
53Carriage of Material from source to site by M.T including loading, unloading and complete job. Cement an average lead of …............................. 5km
54Sand an average lead ….................. 20 km
55Stone Aggregate an average lead ….............. 20 km
56Stone an average lead ….......................... 20km
57Earth an average lead …...................20 km
58Providing and placing on terrace (at all floor levels) polyethylene water storagetank ISI : 12701 marked with cover and suitable locking arrangement and makingnecessary holes for inlet, outlet and overflow pipes but without fittings and thebase support for tank
59Providing and fixing of material for the insulation of pipe with nitrile tube, tapping with cello tape, Rockwood 6 inch per side, wire mesh, polythene, tapping with cellotape aluminium sheet 26 gauge cladding with dia , complete job including 19mm thick 50mm dia ( OD ) PPR 32MM
6019mm thick 50mm dia ( OD ) PPR 40 MM
61Providing and fixing of material for the insulation of pipe with nitrile tube, tapping with cello tape, Rockwood 6 inch per side, wire mesh, polythene, tapping with cellotape for inner wall fittings complete job including carriage 19mm thick,50mm dia ( OD) PRR 25MM
62Providing and fixing of electrical heat tape with thermostat all complete job.
63Steel work in built up tubular (round, square or rectangular hollow tubes etc.)trusses etc., including Hot finished welded type tubes
64Random rubble masonry with hard stone laid dry in foundation, plinth &walls Laid without bond stone
65Marble stone flooring with 18 mm thick marble stone, as per sample of marbleapproved by Engineer-in-charge, over 20 mm (average) thick base of cementmortar 1:4 (1 cement : 4 coarse sand) laid and jointed with grey cement slurry,including rubbing and polishing complete with : Makrana white second quality
66Providing and fixing traditionally carved wood work (Shingstak) over doors andwindows including all accessories as per the direction of the Engineer in-charge,complete with; 2nd class kail wood
67Providing and fixing brass bib cock of approved quality : 15 mm nominal bore
68Providing and fixing thermal insulation with Resin Bonded Fibre glass wool conforming to IS: 8183 havingdensity 24 kg/m3, 50 mm thick, wrapped in 200G Virgin Polythene Bags fixed to wall with screw, rawel plug& washers and held in position by criss crossing GI wire etc. complete as per directions of Engineer-in- Charge.
69Providing and fixing PTMT grating of approved quality and colour. Circular type1 100 mm nominal dia.
70Supplying fixing and testing 15mm CP Health faucet of approoved make with necessary CP flexible hose 750mm long nozzle pipe, CP wall flange Angle valve.
71Supplying & fixing urinal partition with SS screws complete . In each urinals in toilet cluster with including necessary fixing materials etc complete.
72Providing and fixing , testing and commissioning of white glazed large flat back urinals with CP push cock with 32mm dia CP waste coupling with dome type grating, 32mm dia CP bottle trap with extension pipe, urinal spreader, SS bolts and nuts to fix the urinal with hangers and brackets complete with wall flanges etc., complete.
73Chequerred precast cement concrete tiles 22 mm thick in footpath & courtyard,jointed with neat cement slurry mixed with pigment to match the shade of tiles,including rubbing and cleaning etc. complete, on 20 mm thick bed of cement mortar 1:4 (1 cement: 4 coarse sand). Light shade pigment using white cement
74Providing and laying water proofing treatment in sunken portion of WCs,bathroom etc., by applying cement slurry mixed with water proofing cementcompound consisting of applying :(a) First layer of slurry of cement @ 0.488 kg/sqm mixed with water proofing cement compound @ 0.253 kg/sqm. This layer will be allowed to air cure for 4 hours (b) Second layer of slurry of cement @ 0.242 kg/sqm mixed with water proofing cement compound @ 0.126 kg/sqm. This layer will be allowed to air cure for 4 hours followed with water curing for 48 hours. The rate includes preparation of surface, treatment and sealing of all joints, corners, junctions of pipes and masonry with polymer mixed slurry.
75Supply and insulation of satin finish stainless steel AISI 304 Sainless steel handrail and balustrade sustem having 38mm dia ( 2') tube handrail ( 1.5mm gauge ) weight 3.7 kg, erected with chemical grout to be fixed on the top of slab/ skirting ( spigot fixed ) at max c/c distance of 600mm complete with all necessary bends and termination complete, with cover plate, fixing, end terminations, custom bends, as
76Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required. Group A
77Wiring for light/ power plug with 2X4 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit alongwith 1 No. 4 sq. mm FRLS PVC insulated copper conductor single core cable for loop earthing as required.
78Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required. 2 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire
792 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire
802 X 10 sq. mm + 1 X 6 sq. mm earth wire
814 X 10 sq. mm + 2 X 6 sq. mm earth wire
82Supplying and drawing following sizes of FRLS PVC insulatedcopper conductor, single core cable in the existing surface/recessed steel/ PVC conduit as required 1 x 1.5 sq. mm
83Supplying and fixing following modular switch/ socket on theexisting modular plate & switch box including connections butexcluding modular plate etc. as required. 5/6 A switch
843 pin 5/6 A socket outlet
85TV antenna socket outlet
86Supplying and fixing modular blanking plate on the existingmodular plate & switch box excluding modular plate asrequired.
87Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providng and fixing 2 nos. 3 pin 5/6 A modular socket outlet and 2 nos. 5/6 A modular switch, connections etc. as required. (For light plugs to be used in non residential buildings).
88Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 A modular socket outlet and 15/16 A modular switch, connections etc. as required.
89Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder paintedincluding earthing etc. as required. (But without MCB/RCCB/Isolator) 6 way (4 + 18), Double door
908 way (4 + 24), Double door
91Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, \\"C\\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. Single pole
92Single pole and neutral 32 amp
93Supplying , installation testing & commissioning of GI Electrode Earthing with 84mmdia and 3 meter length, with 40mmx6mm thick the electrode Cristaline Conductive material ( CCM) The GI electrode shall be surrounded with BEE MOIST compound to provide maximum contact between the electrode and compound should be eco-friendly GI
94Supplying and laying 25 mm X 5 mm G.I strip at 0.50 metre below ground as strip earth electrode, including connection/ terminating with G.I. nut, bolt, spring, washer etc. as required. (Jointing shall be done by overlapping and with 2 sets of G.I. nutbolt & spring washer spaced at 50mm)
95Providing and fixing 25 mm X 5 mm G.I. strip on surface or inrecess for connections etc. as required.
96Fabrication, supplying , installation testing and commissioning of following pannel made out of 2mm thick M.S sheet,floor mounted, vermin and dust proof , indoor type with suitable size of angle iron legs for grounting in the ground, with lockable type hinged doors, duly painted with provision for fixing of 1 no incomer MCCB, 1No outgoing MCCB, MCCB type change over switch 1 no. including supply and fixing 2 sets of Aluminium Bus Bar , and strips for housing MCB's 72 Nos ,MF Digital Meter and other allied accessories etc.as required ( Make as per annexure)
97Providing and fixing following rating and breaking capacity and pole MCCB with thermomagnetic release and terminal spreaders in existing cubicle panel board including drilling holes in cubicle panel, making connections, etc. as required .400 A,50KA,FPMCCB
98Change over Switch (on Load ) FP 400 Amp
99Supplying and fixing of following rating 240/415 Volt's \\"C\\" Series miniature circuit breaker suitable for lighting and other loads of following poles in the existing MCB DB complete with connections, testing and commissioning (Above to 32 Amp) SPN 63 Amp
100TPN 63 Amp
101Supplying and fixing of 1.1 KV PVC insulated and PVC sheathed XLPE Aluminium Power Cable of following sizes on surface/ surface cable tray/0.50 mtr bleow ground level etc. as required including carriage upto site of work. (Make as per annexure enclosed) 70 sqmm 3.5 core-Armoured
10270 sqmm 3.5 core-Armoured
10320 watt LED tube light fitting LL20-221-XXX-65NE3 wipro or equivalent.
104LED down lighter 12 watt including cutting of Holes.
105LED down lighter 20 watt including cutting of Holes.
106Supplying , installation testing and commissioning of LED 2'x 2' recess mounted fixture that delivers atleast 3000 lumens and wattage not more than 36 watt,
107Supplying and fixing of following electrical items suitable for operating on 240/230Volts AC, 50 Hz supply, including connections etc. as required. Exhaust fan 225 mm PVC shutter type
108Supplying and drawing co-axial TV cable RG-6 grade, 0.7 mm solid copper conductor PE insulated, shielded with fine tinned copper braid and protected with PVC sheath in the existingsurface/ recessed steel/ PVC conduit as required. Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 56684344
AUTHORITY Government Departments
TENDER VALUE 3.75 Crore
LAST DATE 11-08-2026
Authority
Authority Name Public Works Department
Work Description Tender for Construction Of Phc Building At Chushul. ( Under Vvp )
Basic Detail
Tender No E Tender 50of R and B Division Leh
Bidding Type Tender
Location
City Leh
State Ladakh
Key Dates
Publish Date 27 Jul 2026
Submission Date 11 Aug 2026
Open Date 13 Aug 2026
Finance
Tender Value 3.75 Crore
Tender Fee 3751
EMD 7.50 Lakhs
Exemption Not Available
Document List
257bd949-a45b-4e59-bc0d-b82645713852.html
BOQ_45807.xls
Tendernotice_1 (17).pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Jul 27, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Aug 11, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 14 days
Aug 13, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 16 days

Tender Documents

Download All (ZIP) ↓
html

257bd949-a45b-4e59-bc0d-b82645713852.html

xls

BOQ_45807.xls

pdf

Tendernotice_1 (17).pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender