Tender For Supply Installation Testing and Commissioning of 58.5 Kva D.G Set With Amf Panel And Manual By-Pass System At Haringhata Mahavidyalaya, Haringhata, Nadia.
Tender Value
1
Estimated cost
Bid Submission
12 Aug 2026
10 days left
EMD
23622
Bank guarantee accepted
Document Fee
Ref. Documents
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Nadia → West Bengal
EMD Exemption
Not Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender for Supply Installation Testing and Commissioning of 58.5 Kva D.G Set With Amf Panel And Manual By-Pass System At Haringhata Mahavidyalaya, Haringhata, Nadia.
BOQ
| Sl. No. | Item Description |
| 1 | Supply, delivery at site on foundation, Testing & commissioning of 58.5 KVA, 415V, 50Hz, 3Ø silent new DG Set with Spl AMF control panel with Bypass arrangement, comprising of Engine, alternator, Base frame, Fuel tank, Battery, CPCB-II approved Engine & Acoustic Enclosure as per detail specification attached (uploaded in the specification section)[Make- JAKSON/Ashok Leyland/Caterpiller/KOEL/Greaves Power]Engine:-Make : JAKSON/Ashok Leyland/Caterpiller/KOEL/Greaves Power.Engine Type : 4 Stroke Diesel EngineRPM : 1500Rated Power : 47/74.4 Kwe/ BHP Duty : PRIMECooling : Water cooled with radiatorCylinder : 6Aspiration : Turbo Charged Fuel Tank Capacity : Capacity 163 Ltrs. [/or as per Manufacturer's standard]Fuel Consumption at 75% rated Load with Radiator or Fan.Fuel Consumption at 100% rated Load with Radiator or Fan.Overload Capacity : 10% overload for one hour for every 12 hours continuous running at full load or better |
| 2 | Engine instrument Panel : Consisting of starting switch with Key, Lube Oil Indicator, water temperature Indicator, RPM indicator and hour meter.Safety Controls : Emergency Stop, Low Lube Oil Pressure warning/ Shutdown, High Engine Water Temp. warning/ Shutdown, Sensor failure Indicator, Engine over speed indicator, Battery charging and low battery indicatorExhaust Silencer : Residential TypeStarting system : 12V/ 24 V starting system complete with starter motor, charging alternator with rectifier and Cutout as per manufacturer standard.Battery : Lead Acid, Low Maintenance or SMF and conforming to relevant IS Specification with Low/High Battery Voltage and Weak Battery warningAlternatorMake : Stamford/ Leroy SomerRating : 415 V., 3Ph. 50 Hz., 58.5 KVA, 1500 rpmType : Brushless, self excited and self regulated Insulation : Class HProtection : screen-protected drip proof with Min.IP-23 degree of protection |
| 3 | RPM : 1500Voltage Regulation (max) : ±1%Winding connection : Star with NeutralTotal Distortion factor : Less than 3%Total Harmonic distortion in output waveform : < 5% AMF PanelCubical type floor mounted AMF panel made from 14 SWG Sheet Steel, duly pretreated, powder coated painted and aesthetically finished, suitable for controlling of 58.5 KVA DG set having following specification/features.i) 415 V, 125A FP MCCB of Breaking capacity 25/35kA with O/L,S/C,E/F protection and microprocessor based protection release, U/V release etc. with 1 no. 125A FP power contactor-2 sets.[make:Legrand/SIEMENS/L&T/ABB] iii) In Built manual By-Pass switch with capacity 415V, 125A.iv) On -delay timer for load change overv) On-delay timer for engine shut offvi) Engine On-Off switch (Push button type)vii) Battery charger complete with voltage regulator, booster selector switch, on-off switch, voltmeter and ammeter for charging the battery from mains. This will be in addition to the battery charging alternator fitted on the engine |
| 4 | viii) Minimum five number indicating lamps to indicate 'mains ON', 'load on mains', Set running', 'load on set' and 'battery charger on'.ix) Audio visual alarm for 'Low lubricating oil pressure', 'High water temperature, Start failure', and DG over load'. ix) Mode selector for setting the panel on Auto/ Man/ Test Modex) Microprocessor based relay with composite meter for digital display of following.xi) Generator voltage/AC Mains voltage.xii) Generator Current in all phasesxiii) Frequencyxiv) Power Factorxv) Energyxvi)Indication for alternator supplyxvii)Running time indications number of hours of operation and service intervals, service due indicationsThe AMF panel must be designed to ensure trouble free performance and ensure switching over Electrical Load to DG within 15 (fifteen) second from the instant of mains failure. |
| 5 | Acoustic Enclosure The DG set should have integrated acoustic enclosure at the manufacturing state itself. High quality acoustic enclosure must be certified as per CPCB-II norms.Base FrameCommon iron channel fabricated base frame containing the engine and alternator, mounted on AVM pads and having provision for lifting Hook.Terms & Conditions(i) Rate should be quoted inclusive of all applicable taxes and Duty etc.(ii) All materials, equipments & accessories must conform to relevant IS specifications. The DG Set to be supplied must be from the authorized OEM of the respective Engine Manufacturer. (iii) Necessary manufacturer's test certificate for Diesel Engine, Alternator etc. Will have to submit in triplicate copy during delivery of the equipment.(iii) Necessary manufacturer's test certificate for Diesel Engine, Alternator etc. Will have to submit in triplicate copy during delivery of the equipment.(iv) Copy of \\"Type Approval Certificate\\" and Certificate of \\"COP\\" must be produced at the time of delivery issued from competent Authority (As per CPCB-II).(v) Circuit Diagram for AMF Panel must be submitted from the Manufacturer/OEM.(vi) The entire set must be warranted at least 15 months from the date of Delivery/12 months/ 5000 Hrs from the date of Commissioning whichever is earlier. However Engine & Alternator should be warranted of 2 years/5000 Hrs, whichever is earlier. |
| 6 | Supply & fixing of exhaust gas piping of 102 mm dia MS black class B pipe welded incl. all necessary bend supports and clamps anti vibration mounting insulation of exhaust system with 50 mm thick mineral wool covered with wire mesh and aluminium cladding ( from DG sets to top of the building plus 3mtr or as per CPCB) for 58.5 KVA DG set as per direction of EIC. |
| 7 | S&F special type MS angle iron support structure made of MS angle with flat iron clamp with nuts, bolts & washers etc. for 102 mm. dia exhaust pipe. |
| 8 | S&F rain protection canopy for 102 mm exhaust pipe |
| 9 | Hire charges for scaffolding by bamboo required rope of square type arrangement for smooth working & carriage of MS black pipe by vertical run & dismantling at the end of work. |
| 10 | Supply & delivery of best quality oil hand pump with 1\\" dia PVC flexible pipe (12' ft. approx.) |
| 11 | S & pouring (including transportation) of HSD for testing & immediate run of DG set incl. carrying charge |
| 12 | Supply & laying of 1.1 KV grade 10 core 1.5 sq.mm. PVC copper conductor control cable (Mk. Havell's / Polycab / RR Kabel / KEI) on existing cable tray for interconnect DG set with AMF panel. |
| 13 | S & laying 25 sq. mm. single core multistrand PVC insulated flexible Cu wire (Mk. Havell's / Polycab / RR Kabel /KEI) in suitable size of PVC flexible pipe (reinforced) from nutral earth busbar to transformer point as required (for Transformer /Generator neutral earthing) including Socketing both sides by Cu Socket. |
| 14 | Earthing with 65 mm dia GI pipe (TATA-Medium)x 3.0 Mts. long and 1 x 19/10 stranded GI (Hot Dip) wire (4 Mts. long), 20 mm dia x 125 mm long galvanized bolt, double nuts, double washers including socketing at both ends of stranded GI (Hot Dip) wire by crimping sockets/ thimbles and S & F 40 mm dia GI pipe (ISI-Medium) protection (3 Mts. long) to be filled with bitumen partly under the ground level and partly above ground level to an average depth of 3.65 Mts(G1/2c). |
| 15 | Extra for providing masonery enclosure on the top of the earth electrode of overall size 86.36 cm x 86.36 cm x 46 cm deep(below Ground level) complete with cemented brick work(1:6) of 25 cm width duly plastered with cement morter (inside) CI hinged inspection cover of size 36.56 cm x 35.56 cm with locking arrangement, GI reducer including drilling of 46 nos.12 mm dia holes on the GI pipe(G2/3a). |
| 16 | Extra treatment of soil by using salt & charcoal for plate electrode as to G.S. (G-2/3 b) |
| 17 | Supplying & fixing earth busbar of galvanized (Hot Dip) MS flat 40 mm x 6 mm on wall having clearance of 6 mm from wall including providing drilled holes on the busbar complete with GI bolts, nuts, washers, spacing insulators etc. as required(G2/4b). |
| 18 | Connecting the equipments body to earth busbar including S&F 20 mm x 3 mm galvanised (Hot Dip) MS flat on wall/floor with GI saddles as required and connection to equipments incl. drilling holes, with bolts, nuts, washers etc.(G3/c). Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Jul 27, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedAug 12, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 10 daysAug 14, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 12 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender