Tender For Repair To Certain E/M Installations At No 2 Area Under Ge (Af) Srinagar.
Tender Value
38 Lakhs
Estimated cost
Bid Submission
17 Aug 2026
20 days left
EMD
76000
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Budgam → Jammu and Kashmir
EMD Exemption
Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender for Repair To Certain E/M Installations At No 2 Area Under Ge (Af) Srinagar.
BOQ
| Sl. No. | Item Description |
| 1 | Supply and erect in true vertical position 9.50m long steel tubular swaged poles, type 410 SP-37, with 300mm x 300mm x 6mm mild steel base plate continuously welded to pole, finial tapper plug, bolts, nuts and screws and making holes as per requirement all as specified including factory painted with two coats black bituminous paint internally throughout and externally for embedded portion and applying one coat of red oxide primer, making 05 Nos strips each 30 cm high with super enamel paint with alternate (Black and Yellow / White) colour scheme from ground level / coping upto 1.5m painting with two coats of aluminium paint for the remaining height including taking down old swaged pole, complete all as specified and directed. (Note:- Excavation, earth work and PCC will be measured and paid separately in respective items.) |
| 2 | M&L for PCC, 1:4:8, type D-2 (using 40 mm graded crushed stone aggregate) as in foundation filling / mass concrete etc., complete all as specified and directed. |
| 3 | M&L for cement concrete 1:3:6, type C-1 (using 20 mm graded crushed stone aggregate) as in coping for pole and the like, weathering, slightly rounded or chamfered angles including necessary form work, complete all as specified and directed. |
| 4 | M&L for shifting of serviceable / unserviceable transformer / RMU / VCB panels from one location to another location of capacity 63 to 1000 KVA from existing PCC platform / four pole / two pole structure / MES store yard and fixing on platform / four pole / two pole structure by suitable capacity of crane including necessary disconnection and connection on both side and testing on completion, complete all as specified and directed. |
| 5 | M&L for disconnecting of supply from any capacity of panel board / RMU of any capacity and size for over hauling / repair / re-wiring works, servicing and taking out trolley. Dismantling carefully and replacing defective parts found at the time of servicing complete with decarburizing the contact points, cleaning with CRC solution etc including calibration of relays for tripping time setting over current setting, earth fault setting and testing of panel with the help of primary injection test set for protection CT after repair, complete all as specified and directed. |
| 6 | S&F 210 Watt LED flood light fitting, for operating between 110V to 230 V system efficiency not less than 120 lumen / Watt PF-0.95 minimum, IP-66 protection, 5700 CCT (K), CRI between 80-85, confirming to LM79 and LM 80 standards or as per IS-16106:2012, for estimated life span of minimum 50,000 hrs consisting of high/ low voltage cut off, maintenance free isolated electronic driver circuits, Low THD, PMMA grade high quality transmittance lens, epoxy powder coated Die cast aluminium housing with LED street optics LENS for uniform light distribution, weather proof gasket for lamp & driver compartement, heat resistance toughened UV stabilized glass fitted in cast aluminium housing with SS screws with IP-65/66 protection including taking down existing unserviceable light, complete all as specified and directed. |
| 7 | S&F in replacement PVC insulated cu stranded (FRLSH) wire 1.5 sqmm, passing through the non metallic PVC conduit from junction box to LED security light terminals. All connections should be made with proper size of thimbles, complete all as specified and directed. |
| 8 | S&F in replacement of Rigid non-metallic PVC conduit of size 20mm dia exclusive of boxes (junction / terminal) but inclusive of all tees, bends, elbows, reducers, bell mouth tube ends and fixing accessories such as couplers, lock nuts, saddles, pipe hooks etc., complete all as specified and directed. |
| 9 | S&F in replacement PVC weather proof junction boxes of size 250 x 200 x 100mm (Inside dimentions) with PVC connector heavy duty connector 4 way 16 amps ,one No MCB SP 6 Amps and making necessary cable connection, complete all as specified and directed. |
| 10 | S&F in replacement LED bollard lightlight fitting 9W, CCT 5700 K with all fixing accessories fitted on including making suitable foundation for anchoring in PCC 1:2:4, type-B-1, complete all as specified and directed. |
| 11 | S&F in replacement LED 40 Watt post top lantern, 230 watt volts AC, outdoor type with decorative post top for 360 degree indirect light IP-65 protection with impact and corrosion resistant complete with driver and lamp, complete all as specified and directed. |
| 12 | Surface dressing / cleaning of surrounding area of 2/4 pole structure, TR plinth sub stn including removing of tree branches, small tree plants, tarbushes etc., complete all as specified and directed. |
| 13 | M&L for spreading the 20mm coarse aggregate in various sub stations and other locations, complete all as specified and directed. |
| 14 | M&L for spreading the 40mm coarse aggregate in various sub stations and other locations, complete all as specified and directed. |
| 15 | Labour for cutting the bushes and plants grown near the substation / structures premises using necessary tools and plants and removing the plants from the root level at any depth and cleaning the premises completely and making good the site suitable for spreading the stone aggregate including disposing all the waste to a distance not exc 50m form the site, complete all as specified and directed. |
| 16 | S&F in repairs MCCB 4 pole 415 volts fixed type 100 Amps with breaking capacity 16 KA, complete all as specified and directed. |
| 17 | S&F in repairs MCCB 4 pole 415 volts microprocessor release type, 160 Amps with breaking capacity 36 KA, complete all as specified and directed. |
| 18 | S&F in repairs MCCB 4 pole 415 volts microprocessor release type, 200 Amps with breaking capacity 36 KA, complete all as specified and directed. |
| 19 | S&F in repairs MCCB 4 pole 415 volts microprocessor release type, 250 Amps with breaking capacity 36 KA, complete all as specified and directed. |
| 20 | S&F in repairs MCCB 4 pole 415 volts microprocessor release type, 400 Amps with breaking capacity 50 KA, complete all as specified and directed. |
| 21 | S&F in repairs MCCB 4 pole 415 volts microprocessor release type, 630 Amps with breaking capacity 50 KA, complete all as specified and directed. |
| 22 | S&F in repairs MS chequered plate of 6 mm thick confirming to FE-290 grade 165 including provision of lifting handle for each plate on existing cable ducts and manhole covers for semi under ground sumps including painting with two coats of synthetic enamel paint over a coat of red oxide primer, complete all as specified and directed. |
| 23 | M&L for 100mm thick plain cement concrete, 1:4:8, type D-1 (using 20mm graded crushed stone aggregate) as in flooring , laid in alternate bays and finishing the surface even and smooth without using extra cement, complete all as specified and as directed. |
| 24 | Supply, laying, jointing and testing XLPE insulated of cross sectional area 10 Sqmm 4 Core, PVC inner sheathed, armoured with galvanised steel strip or wire, heavy duty, LT underground cable ISI marked with aluminium conductor 1100 volt grade laid in trenches / duct passing through pipe / duct or fixed on pole and connecting and testing etc including taking out existing old unserviceable cable, complete all as specified and directed.Note:- Earthwork, sand cushion, cable cover if required will be measured and paid separately under respective items of this Schedule. |
| 25 | All as per Ser item No 24.00 here in above but cross sectional area 35 Sqmm 3.5 core. |
| 26 | All as per Ser item No 24.00 here in above but cross sectional area 70 Sqmm 3.5 core. |
| 27 | S&F in replacement 1100 volts grade, heavy duty cable PVC insulated aluminium conductor, served with inner sheathing of PVC tape and overall PVC sheathed in service connections suspended by insulating hangers not more than 1 metre apart including 4mm suspension wire, of size 10 Sqmm 2 core cable circular in shape, complete all as specified and directed. |
| 28 | All as per Ser item No 27.00 here in above but cross sectional area 6 Sqmm 2 core. |
| 29 | Laying only XLPE insulated of cross sectional area upto and including 95 Sqmm of any core, PVC inner sheathed, armoured with galvanised steel strip or wire, heavy duty, LT underground cable ISI marked with aluminium conductor 1100 volt grade laid in trenches / duct passing through pipe / duct or fixed on pole and connecting and testing etc including taking out existing old cable, complete all as specified and directed.Note:- Earthwork, sand cushion, cable cover if required will be measured and paid separately under respective items of this Schedule.(ii) LT cable will Be issued under Sch 'B' for free for laying. |
| 30 | All as per Ser item No 29.00 here in above but cross sectional area over 95 Sqmm but upto and including 300 Sqmm of any core. |
| 31 | Supply and filling new transformer oil of BDV not less than 50 KV for Toping up / filling of transformer oil in different transformer, complete all as specified and directed. |
| 32 | M&L for cutting the existing bituminous / hard Standing road surfaces and making good disturbed portion for laying of cable / GI pipe etc. and providing 100mm thick plain cement concrete, 1:2:4, type B-2 (using 20 mm graded crushed stone aggregate) for filling up the area of road cutting surfaces and making good the disturbed surface with existing surface, complete all as specified and directed . |
| 33 | Excavation in trenches, n. exc 1.5 m wide and n. exc 1.5m depth and getting out in for foundation of pole, stay, laying of cable and pipe in any type of soil etc all as specified and directed |
| 34 | Excavation in trenches, n. exc 1.5 m wide and exc 1.5m but n. exc 3.0m depth and getting out in for foundation of pole, stay, laying of cable and pipe in any type of soil etc all as specified and directed |
| 35 | Removing excavated material to a distance n.exc 50 m & depositing where directed at a level n. exc 1.50 m above the starting point complete as specified and directed. |
| 36 | Returing, filling in incl spreading, levelling, watering and well ramming in layers n exc 25cm thick after laying of the cables,jointing & testing complete all as specified and directed. |
| 37 | M&L for laying of bricks well burnt sub class B (old size) laid flat for cable protection width equal to the length of bricks, complete all as specified and directed |
| 38 | M&L for sand cushioning in trenches spreading and consolidation 8 cm thick before laying the cable and 15 cm of the sand after laying the cable but will be measured 18 cm after punning etc., complete all as specified and directed. |
| 39 | S&F in repairs 80mm dia GI tubing, light grade, with all fittings fixed on walls / poles for protection of cable including clamp 02 Nos of size 25x4 mm, nut bolts, washers etc, complete all as specified and directed. |
| 40 | S&F in repairs 100mm dia GI tubing, light grade, with all fittings fixed on walls / poles for protection of cable including clamp 02 Nos of size 25x4 mm, nut bolts, washers etc, complete all as specified and directed. |
| 41 | S&F cross arms, bracings, supports, clamps and back plates fabricated from structural steel sections including nuts, bolts, washers, welding, bending cold or hot, drilling holes for bolts, in any shape or size as indicated or directed and inclusive of one coat red oxide primer, two coats aluminium paint including taking down old cross arm, complete all as specified and directed. |
| 42 | S&F in repairs cable jointing kit for 11 KV (Earthed) grade cable for outdoor termination heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 95 Sqmm 3 core, complete all as specified and all directed. |
| 43 | S&F in repairs cable jointing kit for 11 KV (Earthed) grade cable for outdoor termination heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 120 to 185 Sqmm 3 core, complete all as specified and all directed. |
| 44 | S&F in repairs cable jointing kit for 11 KV (Earthed) grade cable for straight through heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 50 to 95 sqmm, complete all as specified and all directed. |
| 45 | S&F in repairs cable jointing kit for 11 KV (Earthed) grade cable for straight through heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 120 to 185 sqmm, complete all as specified and all directed. |
| 46 | S&F in repairs lightning arrestor (set of three) HT metal oxide surge arrester polymeric type complete with all fittings, rated voltage 12 KV continuous operating voltage 11 KV, normal discharge current 10 KA, 65 KV discharge capacity etc, confirming to IEC-600994-2001, complete all as specified and directed. |
| 47 | M & L for painting of steel tubular 4 pole structure of any capacity complete lenght, by applying one coat of white cement based paint after scraping / brushing and cleaning the Algae on pole and cross arms and a coat of white synthetic enamel painting to pole upto 1.5m from ground level shall be painted by alternate layer of black and yellow enamel paint (30 cms apart) and two coat of aluminium painting shall be done on cross arm and bracing, nut, bolts and washers etc after preperation of surfaces, complete all as specified and directed .Note - One 4 pole structure measured as one job inclusive of HT poles and cross arms complete. |
| 48 | S&F in replacement Air break gang operated switch current rating 400 Amps with 15 Nos insulators, outdoor type, triple pole, mechanically operated, suitable for vertical installation, single break, provided with locking arrangement, consisting of MS Channel, HT post type insulator copper alloy, high pressure, assembly drop out fuses, operating rod 20mm dia GI pipe, medium grade for operating from 1.2m above GL complete including drop out fuses conforming to IS rated voltage 11 KV, complete all as specified and directed. |
| 49 | M&L for earthing complete with galvanized steel earth plate electrode 600mm x 600mm x 6mm buried directly in ground vertically to a depth not less than 2.25 m below normal ground level (with top edge of earth plate not less than 1.5 metre below ground level) connected to galvanized iron earth strip 32 x 6mm (main earthing lead) by means of galvanized bolts, nuts and washers all as shown in electrical plate No 3 of MES Schedule Part-I (2009) connected to earth test point & to main switch board with & including adequate quantity of charcoal dust and common salt alround earth plate & 40 mm dia GI pipe medium grade for earth lead protection pipe for suitable length and GI pipe 20 mm dia medium grade for watering pipe with funnel & wire mesh including necessary earth work and PCC (1: 3 : 6) type C-1 for earth pit , internal surface of concrete shall be given 10mm thick plaster in CM 1:4 and 40 mm thick precast RCC cover 1 : 2 : 4 ,type B-1( using 20 mm graded crushed stone aggregare ) reinforced with 8 mm dia TMT bars @ 75 mm c/c both ways with 12mm dia round bar as in handle including taking down of existing earthing, complete all as specified and directed. NOTE : (i) The cost of earth lead and its protection pipe upto and including 7.5 m only from the top of earth electrode are deemed to be included under this item and additional earth lead , if any, required at site shall be measured and paid for separately under appropriate item of Schedule `A’/BOQ.(ii) Any joint in earth lead from earth electrode to test point shall not be allowed/permitted. |
| 50 | M&L for Aluminium conductor, steel reinforced (ACSR) Code name : Weasel conductor for HT feeders on steel tubular / PCC poles, stretching without kinks and bends including binding wire including taking down old conductor of any type shape and size, complete all as specified and directed. |
| 51 | S&F in replacement breather of transformer made out of high perfoemance plastic material transparemt type with two way low pressure valve weather resistance with IP-65 protection suitable for upto 250 KVA transformer, complete and all as specified and directed. |
| 52 | S&F in replacement breather of transformer made out of high perfoemance plastic material transparemt type with two way low pressure valve weather resistance with IP-65 protection suitable for above 250 KVA upto and incloding 500 KVA transformer, complete and all as specified and directed. |
| 53 | S&F in replacement vaccum interrupter assembly in R and B phases of 11 kv HT breaker, complete all as specified and directed. |
| 54 | S&F in replacement of HT 11 KV CT made up of epoxy resin as primery insulation the core of CT is made of soft iron and copper shall be used for both primery and secondary winding of ratio 100/5A of high accuracy class with a typical error of (+/-) 0.2 %, CT can withstand for specified duration in short circuit fault, confirming to IS 2705, complete all as specified and directed. Please Enable Macros to View BoQ information |
| 55 | S&F in replacement of HT 11 KV CT made up of epoxy resin as primery insulation the core of CT is made of soft iron and copper shall be used for both primery and secondary winding of ratio 100/5A of high accuracy class with a typical error of (+/-) 0.2 %, CT can withstand for specified duration in short circuit fault, confirming to IS 2705, complete all as specified and directed. Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Jul 27, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedAug 17, 2026
17:00 IST