Project Description

Tender for Repair / Maintenance Of Various Capcities Servo Voltage Stabilizer And Connected Works Under Ge (Af) Srinagar.

BOQ

Name of Work:- REPAIR / MAINTENANCE OF VARIOUS CAPCITIES SERVO VOLTAGE STABILIZER AND CONNECTED WORKS UNDER GE (AF) SRINAGAR.
Sl. No. Item Description
1M&L for opening the Servo voltage stabilizer of capacity 200 KVA upto and including 300 KVA by removing the nuts bolts then after removing the internal L.T. connections by taking them out by removing studs, bushings, taking out the winding assembly from tank, removing out burnt parts from the assembly, cleaning of assembly with CTC including necessary repairs for the unserviceable parts and cleaning of sludge deposited in the tank with CTC for the stabilizer. removal of leakage of tank if any by welding, refilling new/ filtered transformer oil to tank, after putting the core-winding assembly into the tank, reassembling making the internal connections by fixing the studs, bushing, fitting the top cover by replacing cork sheet gasket, testing of stabilizer in the workshop duly filled with oil, all as directed by Engineer-in-Charge. Note : Unserviceable parts required for repairs of stabilizer shall be measured and paid separately under relevant item of this schedule as following. Quotated rates shall deemed to be included of disconnection of all connections of Stablizer taking into workshop including transportation, loading and unloading. Transformer oil with die electric strength not less than 45 KV either new or filtered shall be filled and shall be measured and paid separately under respective item.
2Supply only Microprocessor Digital controller display (PCB) ( printed circuit board ) plate.
3Supply only Dimmerstate complete
4Supply only Primary load Coils
5Supply only Carbon Brush Arms Assembly
6Supply only Carbon Brushes
7Supply only SS Shaft
8Supply only Bakelite Palte Base
9Supply only Brass Earth Strip
10Supply only Slow speed high troque synchronizing motor
11Supply only RC network for servo motor
12Supply only control circuit Wiring
13Supply only Unit Switches
14Supply only Aluminium alloy gear
15Supply only Bush/ Bush rods (Input/ Output)
16Supply only Oil Level Indicators
17Supply only Rolling Wheels
18Supply only Buck -Boost Transformer
19Supply only Voltage sensing transformer
20Supply only Power contactor 4p of Cap 500 Amps 415 VAC AC1 type confirming to IEC-60947-4-1
21Supply only Terminal Block and wiring Kit
22Supply only Front Display Metal Sheet of suitable size
23Supply only Top Metal Sheet cover of suitable size
24Supply only manual bypass assembly
25M&L for opening the Servo voltage stabilizer of capacity above 100 KVA upto and including 150 KVA by removing the nuts bolts then after removing the internal L.T. connections by taking them out by removing studs, bushings, taking out the winding assembly from tank, removing out burnt parts from the assembly, cleaning of assembly with CTC including necessary repairs for the unserviceable parts and cleaning of sludge deposited in the tank with CTC for the stabilizer. removal of leakage of tank if any by welding, refilling new/ filtered transformer oil to tank, after putting the core-winding assembly into the tank, reassembling making the internal connections by fixing the studs, bushing, fitting the top cover by replacing cork sheet gasket, testing of stabilizer in the workshop duly filled with oil, all as directed by Engineer-in-Charge. Note : Unserviceable parts required for repairs of stabilizer shall be measured and paid separately under relevant item of this schedule as following. Quotated rates shall deemed to be included of disconnection of all connections of Stablizer taking into workshop including transportation, loading and unloading. Transformer oil with die electric strength not less than 45 KV either new or filtered shall be filled and shall be measured and paid separately under respective item.
26Supply only Microprocessor Digital controller display (PCB) ( printed circuit board ) plate.
27Supply only Dimmerstate complete
28Supply only Primary load Coils
29Supply only Carbon Brush Arms Assembly
30Supply only Carbon Brushes
31Supply only SS Shaft
32Supply only Bakelite Palte Base
33Supply only Brass Earth Strip
34Supply only Slow speed high troque synchronizing motor
35Supply only RC network for servo motor
36Supply only control circuit Wiring
37Supply only Unit Switches
38Supply only Aluminium alloy gear
39Supply only Bush/ Bush rods (Input/ Output)
40Supply only Oil Level Indicators
41Supply only Rolling Wheels
42Supply only Buck -Boost Transformer
43Supply only Voltage sensing transformer
44Supply only Power contactor 4p of Cap 315 Amps 415 VAC AC1 type confirming to IEC-60947-4-1
45Supply only Terminal Block and wiring Kit
46Supply only Front Display Metal Sheet of suitable size
47Supply only Top Metal Sheet cover of suitable size
48Supply only manual bypass assembly
49M&L for opening the Servo voltage stabilizer of capacity above 75 KVA upto and including 100 KVA by removing the nuts bolts then after removing the internal L.T. connections by taking them out by removing studs, bushings, taking out the winding assembly from tank, removing out burnt parts from the assembly, cleaning of assembly with CTC including necessary repairs for the unserviceable parts and cleaning of sludge deposited in the tank with CTC for the stabilizer. removal of leakage of tank if any by welding, refilling new/ filtered transformer oil to tank, after putting the core-winding assembly into the tank, reassembling making the internal connections by fixing the studs, bushing, fitting the top cover by replacing cork sheet gasket, testing of stabilizer in the workshop duly filled with oil, all as directed by Engineer-in-Charge. Note : Unserviceable parts required for repairs of stabilizer shall be measured and paid separately under relevant item of this schedule as following. Quotated rates shall deemed to be included of disconnection of all connections of Stablizer taking into workshop including transportation, loading and unloading. Transformer oil with die electric strength not less than 45 KV either new or filtered shall be filled and shall be measured and paid separately under respective item.
50Supply only Microprocessor Digital controller display (PCB) ( printed circuit board ) plate.
51Supply only Dimmerstate complete
52Supply only Primary load Coils
53Supply only Carbon Brush Arms Assembly
54Supply only Carbon Brushes
55Supply only SS Shaft
56Supply only Bakelite Palte Base
57Supply only Brass Earth Strip
58Supply only Slow speed high troque synchronizing motor
59Supply only RC network for servo motor
60Supply only Power Wiring
61Supply only Unit Switches
62Supply only Aluminium alloy gear
63Supply only Bush/ Bush rods (Input/ Output)
64Supply only Oil Level Indicators
65Supply only Rolling Wheels
66Supply only Buck -Boost Transformer
67Supply only Voltage sensing transformer
68Supply only Power contactor 4p of Cap 160 Amps 415 VAC AC1 type confirming to IEC-60947-4-1
69Supply only Terminal Block and wiring Kit
70Supply only Front Display Metal Sheet of suitable size
71Supply only Top Metal Sheet cover of suitable size
72Supply only manual bypass assembly
73M&L for opening the Servo voltage stabilizer of capacity above 25 KVA upto and including 75 KVA by removing the nuts bolts then after removing the internal L.T. connections by taking them out by removing studs, bushings, taking out the winding assembly from tank, removing out burnt parts from the assembly, cleaning of assembly with CTC including necessary repairs for the unserviceable parts and cleaning of sludge deposited in the tank with CTC for the stabilizer. removal of leakage of tank if any by welding, refilling new/ filtered transformer oil to tank, after putting the core-winding assembly into the tank, reassembling making the internal connections by fixing the studs, bushing, fitting the top cover by replacing cork sheet gasket, testing of stabilizer in the workshop duly filled with oil, all as directed by Engineer-in-Charge. Note : Unserviceable parts required for repairs of stabilizer shall be measured and paid separately under relevant item of this schedule as following. Quotated rates shall deemed to be included of disconnection of all connections of Stablizer taking into workshop including transportation, loading and unloading. Transformer oil with die electric strength not less than 45 KV either new or filtered shall be filled and shall be measured and paid separately under respective item.
74Supply only Microprocessor Digital controller display (PCB) ( printed circuit board ) plate.
75Supply only Dimmerstate complete
76Supply only Primary load Coils
77Supply only Carbon Brush Arms Assembly
78Supply only Carbon Brushes
79Supply only SS Shaft
80Supply only Bakelite Palte Base
81Supply only Brass Earth Strip
82Supply only Slow speed high troque synchronizing motor
83Supply only RC network for servo motor
84Supply only Power Wiring
85Supply only Unit Switches
86Supply only Aluminium alloy gear
87Supply only Bush/ Bush rods (Input/ Output)
88Supply only Oil Level Indicators
89Supply only Rolling Wheels
90Supply only Buck -Boost Transformer
91Supply only Voltage sensing transformer
92Supply only Power contactor 4p of Cap 125 Amps 415 VAC AC1 type confirming to IEC-60947-4-1
93Supply only Terminal Block and wiring Kit
94Supply only Front Display Metal Sheet of suitable size
95Supply only Top Metal Sheet cover of suitable size
96Supply only manual bypass assembly
97M&L for opening the Servo voltage stabilizer of capacity upto and including 25 KVA by removing the nuts bolts then after removing the internal L.T. connections by taking them out by removing studs, bushings, taking out the winding assembly from tank, removing out burnt parts from the assembly, cleaning of assembly with CTC including necessary repairs for the unserviceable parts and cleaning of sludge deposited in the tank with CTC for the stabilizer. removal of leakage of tank if any by welding, refilling new/ filtered transformer oil to tank, after putting the core-winding assembly into the tank, reassembling making the internal connections by fixing the studs, bushing, fitting the top cover by replacing cork sheet gasket, testing of stabilizer in the workshop duly filled with oil, all as directed by Engineer-in-Charge. Note : Unserviceable parts required for repairs of stabilizer shall be measured and paid separately under relevant item of this schedule as following. Quotated rates shall deemed to be included of disconnection of all connections of Stablizer taking into workshop including transportation, loading and unloading. Transformer oil with die electric strength not less than 45 KV either new or filtered shall be filled and shall be measured and paid separately under respective item.
98Supply only Microprocessor Digital controller display (PCB) ( printed circuit board ) plate.
99Supply only Dimmerstate complete
100Supply only Primary load Coils
101Supply only Carbon Brush Arms Assembly
102Supply only Carbon Brushes
103Supply only SS Shaft
104Supply only Bakelite Palte Base
105Supply only Brass Earth Strip
106Supply only Slow speed high troque synchronizing motor
107Supply only RC network for servo motor
108Supply only Power Wiring
109Supply only Unit Switches
110Supply only Aluminium alloy gear
111Supply only Bush/ Bush rods (Input/ Output)
112Supply only Oil Level Indicators
113Supply only Rolling Wheels
114Supply only Buck -Boost Transformer
115Supply only Voltage sensing transformer
116Supply only Power contactor 4p of Cap 40 Amps 415 VAC AC1 type confirming to IEC-60947-4-1
117Supply only Terminal Block and wiring Kit
118Supply only Front Display Metal Sheet of suitable size
119Supply only Top Metal Sheet cover of suitable size
120Supply only manual bypass assembly
121M&L for painting of Servo voltage stabilizer of capacity 20 KVA to 200 KVA by removing of old paint with blow lamp or metal scrubber and apply two coats of synthetic enamel paint over a coat of red oxide primer and writing of SM / MES Nos on each transformer, complete all as specified and directed.Note:- Proper shutdown shall be taken by the contractor before commencement of work. Spray gun shall be used for painting.
122M&L for dehydration of Servo voltage stabilizer of capacity upto 25 KVA including filtration of Servo voltage stabilizer oil by dehydration and filtration plant including testing of sample before and after dehydration and filtration, the dielectric strength to be achieved 40 KV at 2.5mm gap after completion of dehydration and filtration, complete all as specified and directed.Note:- (i) dehydration of Servo voltage stabilizer oil shall be carried out on the site by dehydration machine and the rate quoted is deemed to be inclusive of this provision.(ii) All the Labour work like disconnect of cable and reassemble and drum etc. shall be carried out by contractor by own arrangement.
123All as per Ser item No 7.00 here in above but above 25 KVA upto and including 75 KVA.
124All as per Ser item No 7.00 here in above but above 75 KVA upto and including 100 KVA.
125All as per Ser item No 7.00 here in above but above 100 KVA upto and including 150 KVA.
126All as per Ser item No 7.00 here in above but above 200 KVA upto and including 300 KVA.
127Supply and filling of transformer oil in Servo voltage stabilizer of BDV not less than 50 KV for Toping up / filling of transformer oil in different transformer, complete all as specified and directed.
128Supply, laying, jointing and testing XLPE insulated of cross sectional area 10 Sqmm 4 Core, PVC inner sheathed, armoured with galvanised steel strip or wire, heavy duty, LT underground cable ISI marked with aluminium conductor 1100 volt grade laid in trenches / duct passing through pipe / duct or fixed on pole and connecting and testing etc including taking out existing old unserviceable cable, complete all as specified and directed.Note:- Earthwork, sand cushion, cable cover if required will be measured and paid separately under respective items of this Schedule.
129All as per Ser item No 13.00 here in above but cross sectional area 35 Sqmm 3.5 core.
130All as per Ser item No 13.00 here in above but cross sectional area 400 Sqmm 3.5 core.
131Excavation in trenches, n. exc 1.5 m wide and n. exc 1.5m depth and getting out in for foundation of pole, stay, laying of cable and pipe in any type of soil etc all as specified and directed
132Returning, filling in incl spreading, levelling, watering and well ramming in layers n exc 25cm thick after laying of the cables, jointing & testing complete all as specified and directed.
133Removing excavated material to a distance n.exc 50 m & depositing where directed at a level n. exc 1.50 m above the starting point complete as specified and directed.
134M&L for sand cushioning in trenches spreading and consolidation 8 cm thick before laying the cable and 15 cm of the sand after laying the cable but will be measured 18 cm after punning etc., complete all as specified and directed.
135M&L for laying of bricks well burnt sub class B (old size) laid flat for cable protection width equal to the length of bricks, complete all as specified and directed
136M&L for cutting the existing Bituminous / Hard Standing road surface for laying of cable / GI Pipe etc and providing Plain cement concrete, 1:2:4, type B-2 (using 20mm graded crushed stone aggregate) for filling up the area of road cutting surfaces and making good the disturbed surface with existing surface, complete all as specified and directed
137S&F in repairs 80mm dia GI tubing, light grade, with all fittings fixed on walls / poles, laid in trenches for protection of cable, complete all as specified and directed.
138S&F in repairs 50mm dia GI tubing, light grade, with all fittings fixed on walls / poles, laid in trenches for protection of cable, complete all as specified and directed.
139S&F in repairs LED flood light 120 Watt, 230 V AC outdoor type with thermal management in multiple optics and equipped with IP66 protection, with impact and corrosion resistant complete with driver and lamp, complete all as specified and directed.
140S&F in repairs PVC insulated cu stranded (FRLSH) wire 1.5 sqmm, passing through the non metallic PVC conduit from junction box to LED security light terminals. All connections should be made with proper size of thimbles, complete all as specified and directed.
141S&F in repairs of Rigid non-metallic PVC conduit of size 20mm dia exclusive of boxes (junction / terminal) but inclusive of all tees, bends, elbows, reducers, bell mouth tube ends and fixing accessories such as couplers, lock nuts, saddles, pipe hooks etc., complete all as specified and directed.
142S&F in repairs PVC weather proof junction boxes of size 250 x 200 x 100mm (Inside dimensions) with PVC connector heavy duty connector 4 way 16 amps ,one No MCB SP 6 Amps and making necessary cable connection, complete all as specified and directed.
143S&F in repairs MCCB 4 pole 415 volts fixed type 100 Amps with breaking capacity 16 KA, complete all as specified and directed.
144S&F in repairs MCCB 4 pole 415 volts microprocessor release type, 160 Amps with breaking capacity 36 KA, complete all as specified and directed.
145S&F in repairs MCCB 4 pole 415 volts microprocessor release type, 200 Amps with breaking capacity 36 KA, complete all as specified and directed.
146S&F in repairs MCCB 4 pole 415 volts microprocessor release type, 250 Amps with breaking capacity 36 KA, complete all as specified and directed.
147S&F in repairs MCCB 4 pole 415 volts microprocessor release type, 400 Amps with breaking capacity 50 KA, complete all as specified and directed.
148S&F in repairs MCCB 4 pole 415 volts microprocessor release type, 630 Amps with breaking capacity 50 KA, complete all as specified and directed.
149M&L for earthing complete with galvanized steel earth plate electrode 600mm x 600mm x 6mm buried directly in ground vertically to a depth not less than 2.25 m below normal ground level (with top edge of earth plate not less than 1.5 metre below ground level) connected to galvanized iron earth strip 32 x 6 mm (main earthing lead) by means of galvanized bolts, nuts and washers all as shown in electrical plate No 3 of MES Schedule Part-I (2009) connected to earth test point & to main switch board with & including adequate quantity of charcoal dust and common salt around earth plate & 40 mm dia GI pipe medium grade for earth lead protection pipe for suitable length and GI pipe 20 mm dia medium grade for watering pipe with funnel & wire mesh including necessary earth work and PCC (1: 3 : 6) type C-1 for earth pit , internal surface of concrete shall be given 10mm thick plaster in CM 1:4 and 40 mm thick precast RCC cover 1 : 2 : 4 ,type B-1( using 20 mm graded crushed stone aggregate ) reinforced with 8 mm dia TMT bars @ 75 mm c/c both ways with 12mm dia round bar as in handle including taking down of existing earthing, complete all as specified and directed.
150NOTE : (i) The cost of earth lead and its protection pipe upto and including 7.5 m only from the top of earth electrode are deemed to be included under this item and additional earth lead , if any, required at site shall be measured and paid for separately under appropriate item of Schedule `A’/BOQ.(ii) Any joint in earth lead from earth electrode to test point shall not be allowed/permitted.
151Deduction to be made from BOQ for Schedule 'A' Part-II (Credit Schedule from dismantling / taking down items) worth Rs 73,625.00 during AOC. (Note :- Tenderers shall not quote for this Schedule) Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 56684167
AUTHORITY Statutory Bodies & Commissions/Committees
TENDER VALUE 45 Lakhs
LAST DATE 17-08-2026
Authority
Authority Name Military Engineer Services
Work Description Tender for Repair / Maintenance Of Various Capcities Servo Voltage Stabilizer And Connected Works Under Ge (Af) Srinagar.
Basic Detail
Tender No GE(AF)/SGR-49/2026-27
Bidding Type Tender
Location
City Budgam
State Jammu and Kashmir
Key Dates
Publish Date 27 Jul 2026
Submission Date 17 Aug 2026
Open Date 19 Aug 2026
Finance
Tender Value 45 Lakhs
Tender Fee 500
EMD 90000
Exemption Available
Document List
7ce4b20a-288e-443f-8545-981d9efe59f6.html
BOQ_874903.xls
Tender49.pdf
Tendernotice_1.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Jul 27, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Aug 17, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 20 days
Aug 19, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 22 days

Tender Documents

Download All (ZIP) ↓
html

7ce4b20a-288e-443f-8545-981d9efe59f6.html

xls

BOQ_874903.xls

pdf

Tender49.pdf

pdf

Tendernotice_1.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail
Loading tenders