Tender for Repair / Maintenance Of Various Capcities Servo Voltage Stabilizer And Connected Works Under Ge (Af) Srinagar.
BOQ
| Sl. No. | Item Description |
| 1 | M&L for opening the Servo voltage stabilizer of capacity 200 KVA upto and including 300 KVA by removing the nuts bolts then after removing the internal L.T. connections by taking them out by removing studs, bushings, taking out the winding assembly from tank, removing out burnt parts from the assembly, cleaning of assembly with CTC including necessary repairs for the unserviceable parts and cleaning of sludge deposited in the tank with CTC for the stabilizer. removal of leakage of tank if any by welding, refilling new/ filtered transformer oil to tank, after putting the core-winding assembly into the tank, reassembling making the internal connections by fixing the studs, bushing, fitting the top cover by replacing cork sheet gasket, testing of stabilizer in the workshop duly filled with oil, all as directed by Engineer-in-Charge. Note : Unserviceable parts required for repairs of stabilizer shall be measured and paid separately under relevant item of this schedule as following. Quotated rates shall deemed to be included of disconnection of all connections of Stablizer taking into workshop including transportation, loading and unloading. Transformer oil with die electric strength not less than 45 KV either new or filtered shall be filled and shall be measured and paid separately under respective item. |
| 2 | Supply only Microprocessor Digital controller display (PCB) ( printed circuit board ) plate. |
| 3 | Supply only Dimmerstate complete |
| 4 | Supply only Primary load Coils |
| 5 | Supply only Carbon Brush Arms Assembly |
| 6 | Supply only Carbon Brushes |
| 7 | Supply only SS Shaft |
| 8 | Supply only Bakelite Palte Base |
| 9 | Supply only Brass Earth Strip |
| 10 | Supply only Slow speed high troque synchronizing motor |
| 11 | Supply only RC network for servo motor |
| 12 | Supply only control circuit Wiring |
| 13 | Supply only Unit Switches |
| 14 | Supply only Aluminium alloy gear |
| 15 | Supply only Bush/ Bush rods (Input/ Output) |
| 16 | Supply only Oil Level Indicators |
| 17 | Supply only Rolling Wheels |
| 18 | Supply only Buck -Boost Transformer |
| 19 | Supply only Voltage sensing transformer |
| 20 | Supply only Power contactor 4p of Cap 500 Amps 415 VAC AC1 type confirming to IEC-60947-4-1 |
| 21 | Supply only Terminal Block and wiring Kit |
| 22 | Supply only Front Display Metal Sheet of suitable size |
| 23 | Supply only Top Metal Sheet cover of suitable size |
| 24 | Supply only manual bypass assembly |
| 25 | M&L for opening the Servo voltage stabilizer of capacity above 100 KVA upto and including 150 KVA by removing the nuts bolts then after removing the internal L.T. connections by taking them out by removing studs, bushings, taking out the winding assembly from tank, removing out burnt parts from the assembly, cleaning of assembly with CTC including necessary repairs for the unserviceable parts and cleaning of sludge deposited in the tank with CTC for the stabilizer. removal of leakage of tank if any by welding, refilling new/ filtered transformer oil to tank, after putting the core-winding assembly into the tank, reassembling making the internal connections by fixing the studs, bushing, fitting the top cover by replacing cork sheet gasket, testing of stabilizer in the workshop duly filled with oil, all as directed by Engineer-in-Charge. Note : Unserviceable parts required for repairs of stabilizer shall be measured and paid separately under relevant item of this schedule as following. Quotated rates shall deemed to be included of disconnection of all connections of Stablizer taking into workshop including transportation, loading and unloading. Transformer oil with die electric strength not less than 45 KV either new or filtered shall be filled and shall be measured and paid separately under respective item. |
| 26 | Supply only Microprocessor Digital controller display (PCB) ( printed circuit board ) plate. |
| 27 | Supply only Dimmerstate complete |
| 28 | Supply only Primary load Coils |
| 29 | Supply only Carbon Brush Arms Assembly |
| 30 | Supply only Carbon Brushes |
| 31 | Supply only SS Shaft |
| 32 | Supply only Bakelite Palte Base |
| 33 | Supply only Brass Earth Strip |
| 34 | Supply only Slow speed high troque synchronizing motor |
| 35 | Supply only RC network for servo motor |
| 36 | Supply only control circuit Wiring |
| 37 | Supply only Unit Switches |
| 38 | Supply only Aluminium alloy gear |
| 39 | Supply only Bush/ Bush rods (Input/ Output) |
| 40 | Supply only Oil Level Indicators |
| 41 | Supply only Rolling Wheels |
| 42 | Supply only Buck -Boost Transformer |
| 43 | Supply only Voltage sensing transformer |
| 44 | Supply only Power contactor 4p of Cap 315 Amps 415 VAC AC1 type confirming to IEC-60947-4-1 |
| 45 | Supply only Terminal Block and wiring Kit |
| 46 | Supply only Front Display Metal Sheet of suitable size |
| 47 | Supply only Top Metal Sheet cover of suitable size |
| 48 | Supply only manual bypass assembly |
| 49 | M&L for opening the Servo voltage stabilizer of capacity above 75 KVA upto and including 100 KVA by removing the nuts bolts then after removing the internal L.T. connections by taking them out by removing studs, bushings, taking out the winding assembly from tank, removing out burnt parts from the assembly, cleaning of assembly with CTC including necessary repairs for the unserviceable parts and cleaning of sludge deposited in the tank with CTC for the stabilizer. removal of leakage of tank if any by welding, refilling new/ filtered transformer oil to tank, after putting the core-winding assembly into the tank, reassembling making the internal connections by fixing the studs, bushing, fitting the top cover by replacing cork sheet gasket, testing of stabilizer in the workshop duly filled with oil, all as directed by Engineer-in-Charge. Note : Unserviceable parts required for repairs of stabilizer shall be measured and paid separately under relevant item of this schedule as following. Quotated rates shall deemed to be included of disconnection of all connections of Stablizer taking into workshop including transportation, loading and unloading. Transformer oil with die electric strength not less than 45 KV either new or filtered shall be filled and shall be measured and paid separately under respective item. |
| 50 | Supply only Microprocessor Digital controller display (PCB) ( printed circuit board ) plate. |
| 51 | Supply only Dimmerstate complete |
| 52 | Supply only Primary load Coils |
| 53 | Supply only Carbon Brush Arms Assembly |
| 54 | Supply only Carbon Brushes |
| 55 | Supply only SS Shaft |
| 56 | Supply only Bakelite Palte Base |
| 57 | Supply only Brass Earth Strip |
| 58 | Supply only Slow speed high troque synchronizing motor |
| 59 | Supply only RC network for servo motor |
| 60 | Supply only Power Wiring |
| 61 | Supply only Unit Switches |
| 62 | Supply only Aluminium alloy gear |
| 63 | Supply only Bush/ Bush rods (Input/ Output) |
| 64 | Supply only Oil Level Indicators |
| 65 | Supply only Rolling Wheels |
| 66 | Supply only Buck -Boost Transformer |
| 67 | Supply only Voltage sensing transformer |
| 68 | Supply only Power contactor 4p of Cap 160 Amps 415 VAC AC1 type confirming to IEC-60947-4-1 |
| 69 | Supply only Terminal Block and wiring Kit |
| 70 | Supply only Front Display Metal Sheet of suitable size |
| 71 | Supply only Top Metal Sheet cover of suitable size |
| 72 | Supply only manual bypass assembly |
| 73 | M&L for opening the Servo voltage stabilizer of capacity above 25 KVA upto and including 75 KVA by removing the nuts bolts then after removing the internal L.T. connections by taking them out by removing studs, bushings, taking out the winding assembly from tank, removing out burnt parts from the assembly, cleaning of assembly with CTC including necessary repairs for the unserviceable parts and cleaning of sludge deposited in the tank with CTC for the stabilizer. removal of leakage of tank if any by welding, refilling new/ filtered transformer oil to tank, after putting the core-winding assembly into the tank, reassembling making the internal connections by fixing the studs, bushing, fitting the top cover by replacing cork sheet gasket, testing of stabilizer in the workshop duly filled with oil, all as directed by Engineer-in-Charge. Note : Unserviceable parts required for repairs of stabilizer shall be measured and paid separately under relevant item of this schedule as following. Quotated rates shall deemed to be included of disconnection of all connections of Stablizer taking into workshop including transportation, loading and unloading. Transformer oil with die electric strength not less than 45 KV either new or filtered shall be filled and shall be measured and paid separately under respective item. |
| 74 | Supply only Microprocessor Digital controller display (PCB) ( printed circuit board ) plate. |
| 75 | Supply only Dimmerstate complete |
| 76 | Supply only Primary load Coils |
| 77 | Supply only Carbon Brush Arms Assembly |
| 78 | Supply only Carbon Brushes |
| 79 | Supply only SS Shaft |
| 80 | Supply only Bakelite Palte Base |
| 81 | Supply only Brass Earth Strip |
| 82 | Supply only Slow speed high troque synchronizing motor |
| 83 | Supply only RC network for servo motor |
| 84 | Supply only Power Wiring |
| 85 | Supply only Unit Switches |
| 86 | Supply only Aluminium alloy gear |
| 87 | Supply only Bush/ Bush rods (Input/ Output) |
| 88 | Supply only Oil Level Indicators |
| 89 | Supply only Rolling Wheels |
| 90 | Supply only Buck -Boost Transformer |
| 91 | Supply only Voltage sensing transformer |
| 92 | Supply only Power contactor 4p of Cap 125 Amps 415 VAC AC1 type confirming to IEC-60947-4-1 |
| 93 | Supply only Terminal Block and wiring Kit |
| 94 | Supply only Front Display Metal Sheet of suitable size |
| 95 | Supply only Top Metal Sheet cover of suitable size |
| 96 | Supply only manual bypass assembly |
| 97 | M&L for opening the Servo voltage stabilizer of capacity upto and including 25 KVA by removing the nuts bolts then after removing the internal L.T. connections by taking them out by removing studs, bushings, taking out the winding assembly from tank, removing out burnt parts from the assembly, cleaning of assembly with CTC including necessary repairs for the unserviceable parts and cleaning of sludge deposited in the tank with CTC for the stabilizer. removal of leakage of tank if any by welding, refilling new/ filtered transformer oil to tank, after putting the core-winding assembly into the tank, reassembling making the internal connections by fixing the studs, bushing, fitting the top cover by replacing cork sheet gasket, testing of stabilizer in the workshop duly filled with oil, all as directed by Engineer-in-Charge. Note : Unserviceable parts required for repairs of stabilizer shall be measured and paid separately under relevant item of this schedule as following. Quotated rates shall deemed to be included of disconnection of all connections of Stablizer taking into workshop including transportation, loading and unloading. Transformer oil with die electric strength not less than 45 KV either new or filtered shall be filled and shall be measured and paid separately under respective item. |
| 98 | Supply only Microprocessor Digital controller display (PCB) ( printed circuit board ) plate. |
| 99 | Supply only Dimmerstate complete |
| 100 | Supply only Primary load Coils |
| 101 | Supply only Carbon Brush Arms Assembly |
| 102 | Supply only Carbon Brushes |
| 103 | Supply only SS Shaft |
| 104 | Supply only Bakelite Palte Base |
| 105 | Supply only Brass Earth Strip |
| 106 | Supply only Slow speed high troque synchronizing motor |
| 107 | Supply only RC network for servo motor |
| 108 | Supply only Power Wiring |
| 109 | Supply only Unit Switches |
| 110 | Supply only Aluminium alloy gear |
| 111 | Supply only Bush/ Bush rods (Input/ Output) |
| 112 | Supply only Oil Level Indicators |
| 113 | Supply only Rolling Wheels |
| 114 | Supply only Buck -Boost Transformer |
| 115 | Supply only Voltage sensing transformer |
| 116 | Supply only Power contactor 4p of Cap 40 Amps 415 VAC AC1 type confirming to IEC-60947-4-1 |
| 117 | Supply only Terminal Block and wiring Kit |
| 118 | Supply only Front Display Metal Sheet of suitable size |
| 119 | Supply only Top Metal Sheet cover of suitable size |
| 120 | Supply only manual bypass assembly |
| 121 | M&L for painting of Servo voltage stabilizer of capacity 20 KVA to 200 KVA by removing of old paint with blow lamp or metal scrubber and apply two coats of synthetic enamel paint over a coat of red oxide primer and writing of SM / MES Nos on each transformer, complete all as specified and directed.Note:- Proper shutdown shall be taken by the contractor before commencement of work. Spray gun shall be used for painting. |
| 122 | M&L for dehydration of Servo voltage stabilizer of capacity upto 25 KVA including filtration of Servo voltage stabilizer oil by dehydration and filtration plant including testing of sample before and after dehydration and filtration, the dielectric strength to be achieved 40 KV at 2.5mm gap after completion of dehydration and filtration, complete all as specified and directed.Note:- (i) dehydration of Servo voltage stabilizer oil shall be carried out on the site by dehydration machine and the rate quoted is deemed to be inclusive of this provision.(ii) All the Labour work like disconnect of cable and reassemble and drum etc. shall be carried out by contractor by own arrangement. |
| 123 | All as per Ser item No 7.00 here in above but above 25 KVA upto and including 75 KVA. |
| 124 | All as per Ser item No 7.00 here in above but above 75 KVA upto and including 100 KVA. |
| 125 | All as per Ser item No 7.00 here in above but above 100 KVA upto and including 150 KVA. |
| 126 | All as per Ser item No 7.00 here in above but above 200 KVA upto and including 300 KVA. |
| 127 | Supply and filling of transformer oil in Servo voltage stabilizer of BDV not less than 50 KV for Toping up / filling of transformer oil in different transformer, complete all as specified and directed. |
| 128 | Supply, laying, jointing and testing XLPE insulated of cross sectional area 10 Sqmm 4 Core, PVC inner sheathed, armoured with galvanised steel strip or wire, heavy duty, LT underground cable ISI marked with aluminium conductor 1100 volt grade laid in trenches / duct passing through pipe / duct or fixed on pole and connecting and testing etc including taking out existing old unserviceable cable, complete all as specified and directed.Note:- Earthwork, sand cushion, cable cover if required will be measured and paid separately under respective items of this Schedule. |
| 129 | All as per Ser item No 13.00 here in above but cross sectional area 35 Sqmm 3.5 core. |
| 130 | All as per Ser item No 13.00 here in above but cross sectional area 400 Sqmm 3.5 core. |
| 131 | Excavation in trenches, n. exc 1.5 m wide and n. exc 1.5m depth and getting out in for foundation of pole, stay, laying of cable and pipe in any type of soil etc all as specified and directed |
| 132 | Returning, filling in incl spreading, levelling, watering and well ramming in layers n exc 25cm thick after laying of the cables, jointing & testing complete all as specified and directed. |
| 133 | Removing excavated material to a distance n.exc 50 m & depositing where directed at a level n. exc 1.50 m above the starting point complete as specified and directed. |
| 134 | M&L for sand cushioning in trenches spreading and consolidation 8 cm thick before laying the cable and 15 cm of the sand after laying the cable but will be measured 18 cm after punning etc., complete all as specified and directed. |
| 135 | M&L for laying of bricks well burnt sub class B (old size) laid flat for cable protection width equal to the length of bricks, complete all as specified and directed |
| 136 | M&L for cutting the existing Bituminous / Hard Standing road surface for laying of cable / GI Pipe etc and providing Plain cement concrete, 1:2:4, type B-2 (using 20mm graded crushed stone aggregate) for filling up the area of road cutting surfaces and making good the disturbed surface with existing surface, complete all as specified and directed |
| 137 | S&F in repairs 80mm dia GI tubing, light grade, with all fittings fixed on walls / poles, laid in trenches for protection of cable, complete all as specified and directed. |
| 138 | S&F in repairs 50mm dia GI tubing, light grade, with all fittings fixed on walls / poles, laid in trenches for protection of cable, complete all as specified and directed. |
| 139 | S&F in repairs LED flood light 120 Watt, 230 V AC outdoor type with thermal management in multiple optics and equipped with IP66 protection, with impact and corrosion resistant complete with driver and lamp, complete all as specified and directed. |
| 140 | S&F in repairs PVC insulated cu stranded (FRLSH) wire 1.5 sqmm, passing through the non metallic PVC conduit from junction box to LED security light terminals. All connections should be made with proper size of thimbles, complete all as specified and directed. |
| 141 | S&F in repairs of Rigid non-metallic PVC conduit of size 20mm dia exclusive of boxes (junction / terminal) but inclusive of all tees, bends, elbows, reducers, bell mouth tube ends and fixing accessories such as couplers, lock nuts, saddles, pipe hooks etc., complete all as specified and directed. |
| 142 | S&F in repairs PVC weather proof junction boxes of size 250 x 200 x 100mm (Inside dimensions) with PVC connector heavy duty connector 4 way 16 amps ,one No MCB SP 6 Amps and making necessary cable connection, complete all as specified and directed. |
| 143 | S&F in repairs MCCB 4 pole 415 volts fixed type 100 Amps with breaking capacity 16 KA, complete all as specified and directed. |
| 144 | S&F in repairs MCCB 4 pole 415 volts microprocessor release type, 160 Amps with breaking capacity 36 KA, complete all as specified and directed. |
| 145 | S&F in repairs MCCB 4 pole 415 volts microprocessor release type, 200 Amps with breaking capacity 36 KA, complete all as specified and directed. |
| 146 | S&F in repairs MCCB 4 pole 415 volts microprocessor release type, 250 Amps with breaking capacity 36 KA, complete all as specified and directed. |
| 147 | S&F in repairs MCCB 4 pole 415 volts microprocessor release type, 400 Amps with breaking capacity 50 KA, complete all as specified and directed. |
| 148 | S&F in repairs MCCB 4 pole 415 volts microprocessor release type, 630 Amps with breaking capacity 50 KA, complete all as specified and directed. |
| 149 | M&L for earthing complete with galvanized steel earth plate electrode 600mm x 600mm x 6mm buried directly in ground vertically to a depth not less than 2.25 m below normal ground level (with top edge of earth plate not less than 1.5 metre below ground level) connected to galvanized iron earth strip 32 x 6 mm (main earthing lead) by means of galvanized bolts, nuts and washers all as shown in electrical plate No 3 of MES Schedule Part-I (2009) connected to earth test point & to main switch board with & including adequate quantity of charcoal dust and common salt around earth plate & 40 mm dia GI pipe medium grade for earth lead protection pipe for suitable length and GI pipe 20 mm dia medium grade for watering pipe with funnel & wire mesh including necessary earth work and PCC (1: 3 : 6) type C-1 for earth pit , internal surface of concrete shall be given 10mm thick plaster in CM 1:4 and 40 mm thick precast RCC cover 1 : 2 : 4 ,type B-1( using 20 mm graded crushed stone aggregate ) reinforced with 8 mm dia TMT bars @ 75 mm c/c both ways with 12mm dia round bar as in handle including taking down of existing earthing, complete all as specified and directed. |
| 150 | NOTE : (i) The cost of earth lead and its protection pipe upto and including 7.5 m only from the top of earth electrode are deemed to be included under this item and additional earth lead , if any, required at site shall be measured and paid for separately under appropriate item of Schedule `A’/BOQ.(ii) Any joint in earth lead from earth electrode to test point shall not be allowed/permitted. |
| 151 | Deduction to be made from BOQ for Schedule 'A' Part-II (Credit Schedule from dismantling / taking down items) worth Rs 73,625.00 during AOC. (Note :- Tenderers shall not quote for this Schedule) Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Jul 27, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedAug 17, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 20 daysAug 19, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 22 daysTender Documents
Download All (ZIP) ↓