Project Description

Tender for maintenance of Various Sports Complexes. Sub Head : Running, Maintenance And Operation Of 11/0.415 Kv Sub-Station Equipments, Dg Set, Internal, External & High Mast Lighting, Submersible Pump, Fire Equipments, Air Conditioning, Water Cooler & Ro Units At Rohini Sport Complex Sec-14, Dda.

BOQ

Name of Work:- M/o Various Sports Complexes. Sub Head : Running, Maintenance and Operation of 11/0.415 KV Sub-Station equipments, DG set, Internal, External & high mast lighting, Submersible pump, Fire equipments, Air Conditioning, Water cooler & RO units at Rohini Sport Complex Sec-14, DDA.
Sl. No. Item Description
1Operation and routine maintenance of sub-station equipment having Oil type transformers 630 KVA - 1 no. (11 KV/415 V Indoor type) i/c HT panel, L.T. panels, capacitor panels & Floor panels etc. and 1 No. of 160 KVA D.G. sets i/c other allied panels and Running Maintenance & Operation of Internal Electrical Installations (IEI) and External Lighting including high mast lighting by deploying following staff as per inventory and additional Terms and conditions attached etc.complete as reqd.a) Electrician cum Operator - 3 Nos.(1 No. in each shift total three shift i.e. 6 AM to 2 PM & 2 PM to 10 PM & 10PM to 6AM )b) Khallasi - 2 Nos. ( 1 No. in each shift total two shift i.e. 6 AM to 2 PM & 2 PM to 10 PM ).(Note: All Tools and Plants (T&P) including tower wagon suitable to maintained fittings mounted up to height 12 Mtrs. shall be made available at the site throughout the contract period by agency.)
2Servicing (B-Check Maintenance) of 160 KVA DG set by OEM / authorised dealer i/c replacement of following spare parts/items etc. complete as requireda) Fuel filter- 2 No.b) cartridge and lubricant oil filter -2 No.c) Water Separator from fuel- 1 No.d) Inhibitor -3 Nos.e) Coolant test Kit- 1 No.f) Radiwash - 3 Ltrg) Air filter(Safety)- 1 No.h) Air filter(Primary)- 1 No.i) Lubricating oil & engine oil as required
3Servicing of H.T. OCB Complete with dismantling, Cleaning, alignment, adjustment of gaps between phases, lubricating all moving parts adjustment for smooth mechanical operation etc complete as required.
4Testing and Calibration of IDMT relay with secondary injection test set i.e. cleaning servicing of contacts tightening of loose contacts testing repair etc., complete as required.
5Servicing / Overhauling 800/1000 Amp ACB's with dismantling, cleaning, alignment, adjustment of gaps between phase, lubricating all moving parts adjustment for smooth mechanical operation etc complete as required.
6Dehydration & filtration of transformer oil (630 KVA transformer indoor ONAN) to upgrade the dielectric strength of oil upto 50 KV as required including topup of transfer oil etc. complete as required.
7Supplying and filling of fresh transformer oil in existing transformer etc complete as required.
8Providing and fixing following rating and breaking capacity and pole MCCB with thermomagnetic release and terminal spreaders in existing cubicle panel board including drilling holes in cubicle panel, making connections, etc. as required.
963 A,25KA,FPMCCB
10100 A,30KA,FPMCCB
11125A,36 KA, FP MCCB
12250 A,36KA,FPMCCB
13400 A,50KA,FPMCCB
14Supplying and making straight through joint with heat shrinkable kit including ferrules and other jointing materials for following size of PVC insulated and PVC sheathed/ XLPE aluminum conductor cable of 1.1KV grade as reqd.
153½ Cx 185 sq.mm
163½ Cx 95 sq.mm
174Cx 50 sq.mm
18Labour and T&P charges for locating fault in LT cable by fault locating equipment including pin pointing of particular location of fault etc as required.
19Digging of Pit for providing cable joint as per site located by fault Locator machine including refilling of soil complete as required.
20Supplying and drawing following sizes of FRLS/HFFR PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required.
213x 1.5 sq.mm
223x 2.5 sq.mm
233x 4.0 sq.mm
24Supplying and fixing following modular switch /Socket on the existing modular plate & switch box including connection but excluding modular plate etc. as required.
255/6 Amp Switch.
2615/16 Amp Switch.
273 pin 5/6 Amp Socket outlet.
286 pin 15/16 Amp socket outlet.
29Supplying of following MCB's for Electrical Panel Board/ feeder pillar/ pole including testing etc as required.
306 to 32 Amp SP MCB \\"C\\" series. (10 KA Capacity)
3132 Amp DP MCB \\"C\\" series. (10 KA Capacity)
32Supply of PVC insulated and PVC sheathed / XLPE armoured aluminium conductor power cable (As per IS 7098 (Part-1) of 1.1 KV grade i/c connection testing etc.as required.
333.5 x 70 sq.mm
344 x 50 sq.mm
352 x 16 sq.mm
36Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing RCC/ HUME/ METAL pipe as required.a) upto 35 sqmm
37Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing RCC/ HUME/ METAL pipe as required.a) Above 35 sq. mm and upto 95 sq. mm
38Supplying and laying of following size DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting, jointing etc.direct in ground (75 cm below ground level including excavation and refilling the trench but excluding sand cushioning and protective covering etc., complete as required. 63 mm dia (OD-63 mm & ID-51 mm nominal)
39Supplying and laying of following size DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting, jointing etc.direct in ground (75 cm below ground level) including excavation and refilling the trench but excluding sand cushioning and protective covering etc., complete as required.a)90 mm dia (OD-90 mm & ID-76 mm nominal)
40Comprehensive Maintenance of 7 Nos. RO System 50 LPH capacity & water coolers i/c (cleaning of All Filters), repair/ replacement of all electrical and electronic spare parts and consumables like Particulate Filter 20” or (2 x 10”), Sediment Filter 20” or (2 x 10”), Pre Carbon Filter 20” and (except membranes), attending complaints within 24 working hours with complete overhauling and servicing etc. as required. except replacement of membranes set of 4x75 GPD as per condition attached.
41Replacement of RO TFC Membrane 75 GPD i/c testing, commissioning etc. as required old dismantle shall be retained by the contractor
42Supply and replacement of feed water pressure generating pump with automated switch for 50 LPH capacity RO system etc complete as required.
43Supply, Replacement, Testing & Commissioning of Mushroom Bell Brass Nozzle in existing fountain etc complete as required.
44Supply, Replacement, Testing & Commissioning of Adjustable Type Fountain Nozzle Size 3mm Ball Joint Jet Brass Nozzle in existing fountain etc complete as required
45Service of following type air conditioner upto 2.0 ton capacity i/c cleaning of cooling coil & condenser with chemical, washing the complete air-conditioner, painting of sheet metal parts hose plate with synthetic enamel i/c painting of exposed cooling & condenser pipes with anti corrosion paint, oiling of fan motor, etc as required.
46Split type
47Servicing of water cooler 40/80/120/150 ltr. Capacity oiling in fan motor, Cleaning of base plate and condenser coil with chemical and cleaning of water tank etc. complete as required.
48Supply and replacement of burnt compressor with new compressor including flushing the system, leakage, testing, vacumising, cleaning of condenser, gas charging, cartage i/c testing and commencing complete as required.
49Rotary compressor
50Supplying & replacement of condenser coil suitable for various make of split type air-conditioner of 2.0 Ton capacity having copper piping, i/c welding, pressure testing etc as required.
51Supplying & replacement of Evaporating coil suitable for various make of split type air-conditioner of 2 ton capacity having copper piping, i/c welding, pressure testing etc as required.
52Supply and charging of refrigerant for 2.0 Ton capacity following type air conditioner of various make i/c testing of pressure and cooling etc. complete as required.
53Split Type /Ref Charging
54Repairing of PCB of Split type AC i/c connection, testing etc. complete as required.
55Rewinding of fan motor 2.0 Ton capacity Air conditione i/c replacement of Gun Metal bushes and testing etc. Complete as required.
56Routine preventive maintenance of Air conditioners upto 2 ton capacity & water coolers i/c attending & removal of day day complaints, cleaning of filters & grills of A.C. cleaning of water tank ,complete as required by deputing 1 no of A.C. mechanic and 1 no. khallasi for 1/3 day or as and when required.a) Summer Season
57b) Winter Season
58Supplying and replacement of following part of air conditioner i/c connection, testing etc complete as required.
59Front grill suitable for existing Air Conditioners.
60Running capacitor (36 MFD/50 MFD)
61Capacitor 6 MFD
62Rewinding of fan motor suitable for 150 Ltr capacity water cooler i/c replacement of bushes, testing, commissioning etc. complete as require.
63Supply and replacement of following part in water cooler i/c connection, testing etc. complete as required
64Thermostat
65Over load protection with relay box
66Float Valve Assembly
67Water tap
68Supplying and installation of Copper refrigerant piping(Liquid + gas)with suitable size of insulation ,tie rod ,hanger etc.complete as required.
69Supplying and installation of suitable motor for idu/odu uints. i/c connection,testing etc. complete as required.
70Installation of Split/window type air conditioner including providing and fixing wooden frame for fixing the housing of air conditioner on the existing window testing etc. complete as required.
71Supplying and replacement of unserviceable pair of PCB for both indoor unit and out door unit of air conditioner, suitable for various make of 2 Ton inverter type air conditioner i.c connection,testing etc. complete as required.
72Refilling of fire extingusher including re-installing the same of following type and capacity etc complete as required. i/c labeling etc.
73Trolly Mounted ABC DRY powder based fire extingusher 25Kg.
74Carbon dioxide (CO2) type fire extingusher 4.5Kg
75ABC DRY powder based fire extingusher 2 Kg
76ABC DRY powder based fire extingusher 4 Kg
77ABC DRY powder based fire extingusher 5 Kg
78mechanical foam type 9 Ltrs capcity
79providing and installation one set (6 nos buckets set) galvanized mild steel fire buckets with stand and canopy suitable for 6 buckets, bucket should be as per IS-2546 etc complete as required.
80Lifting out of submersible pump set from the exiting bore well up to the required depth along-with existing G.I. pipes and accessories etc. i/c dismantling of G.I pipe and disconnecting the sub. cable etc. complete as reqd.
81Lowering of sub. pump set in the existing bore well up to the required depth along with existing G.I pipe and sub. cableetc , water proof jointing of sub. cable. Replacement of reqd. nuts, bolts, washers and packing, nipple, reducer, connection testing, etc. complete as reqd.
82Supplying of copper conductor flat submersible cable of following size i/c testing,connection etc. complete as reqd.
833 x 2.5 sq.mm
843 x 10 sq.mm
85Supplying of following size of double G.I. flanged (ISI marked ) GI pipe 'B' class duly threaded & welded with necessary pipe fittings, bends, elbow etc. complete as reqd. a) 65 mm dia.
86Supplying of following size of double G.I. flanged (ISI marked ) GI pipe 'B' class duly threaded & welded with necessary pipe fittings, bends, elbow etc. complete as reqd. a) 50 mm dia.
87Repairing & rewinding of 3 phase sub./single phase motors of following capacity with cartage, dismantling, reassembling i/c supply &replacememt / repairing of damaged parts of motors and making good for operation i/c connection, testing, painting etc. complete as reqd.
885 HP sub. motors
893 HP sub. motors
90Repairing of sub. pump of the following stages &dia with cartage, dismantling, reassembling, supply & replacement / repairing of damaged parts of pump and making good for operation i/c testing painting etc. complete as reqd.
91Up to all stages 6\\"dia submersible pump sets.
92Up to all stages 4\\"dia submersible pump sets
93Repairing & rewinding of following capacity 3 phase open well sub pump sets including cartage, dismantling, reassembling, supplying & replacement/ repairing of damaged parts of pump sets and making good for operation including connection testing, painting etc. complete as required.
945 H.P
95Repairing, Rewinding & servicing of sub. Dewatering pump set i/c repairing / replacement of following worn out part and testing etc as required. i) .5KW/.75 KW/1.1KW pump set.
96Supplying & replacement of following control gear / accessories in the existing installation for electric panel boards, motor starters, connection, testing etc. as reqd.
97Single Phase Preventer
98D.O.L starter (9-14 Ampere)
99Supplying of sub. Pump set duly coupled with suitable rating 3 phase, 415 volt, 50Hz, sub. Motor. The pump sets shall be suitable for the following duties. a) Head Range:- 72-24 Mtr. Discharge Range :- 130-500 LPM. Minimum HP/Stage:- 5 HP/6 Stage. Outlet Size:- 50 mm
100Supplying of sub. Pump set duly coupled with suitable rating Three phase, 415 volt, 50Hz, sub. Motor. The pump sets shall be suitable for the following duties. a) Head Range:- 6-55 Mtr. Discharge Range :-450-100 LPM. Minimum HP/Stage:- 3 HP/5 Stage. Outlet Size:-50 mm
101Taken out of fallen & stuck sub. pump set from the existing bore well up to all depth including sub. cable, G.I. Pipe etc. complete as reqd.
102Providing and fixing 6 SWG dia G.I. wire on surface or in recess for loop earthing along with existing surface/ recessed conduit/ submain wiring/ cable as required
103Supplying and fixing 32 A rating, 240/415 V, 10 kA, \\"C\\" curve, miniature circuit breaker suitable for inductive load of triple pole & neutral in the existing MCB DB complete with connections, testing and commissioning etc. as required.
104Annual maintenance of IEI lighting, split/wall window AC, wall fan, ceiling fan & all existing electrical installetions at (multi gym of Rohini Sec-3,Avantika Rohini Se-1 & Harsh Vihar) 1. No. of wireman for 1 day in a week for 52 week as per direction of Engineer in Charge.2. 1 No. of Khallasi for day in a week for 52 week as per direction Engineer-in Charge.All tools & plants including safety kit to be arranged by the agency as per site requirement or as and when required.
105Repairing of existing feeder pillar i/c replacement of 2mm CRCA sheet in front /side door with welding of hinges, gasketted cover, handle, locking arrangement
106Painting and number of existing GI/MS Tubular pole of dia 65mm/80 mm/100 upto 6 mtr. Height with two coats of synthetic enamel paint i/c removing of all possible rust from the pole before painting etc complete as required.
107Supplying, installation, Testing & Commissioning of 72W Street light LED fixture powder coated pressure die cast aluminium body with driver as per the requirement with Driver efficiency >85%, Input voltage: 140-270 Volt AC, frequency 50/60 hz, Operating temp range -5 0C to 50 0C, internal surge protection of 5 KV L,N,E as per IEC 61000-4-5, Driver efficiency >85%,THD < 10% as per IEC 61000-3-2, P. F.≥0.95, IP-66,IK-10, CRI >70, under voltage and over voltage protection, EMIEMC As per CISPR 15 , lenses for beam angle as per IESNA type I/II/III as per the width of the road and the project requirement., suitable to fit in up to 65mm dia pipe, life time (LED, Driver & electricalcircuitry) of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends as per LM80 extrapolation IES TM-21-11 report, CCT 3000°K / 4000°K / 5700°K /6500°K (As per ANSI Bin), SDCM(Standard Deviation Colour Matching) <5, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard complete in all respect i/c external connections with 1.5 sq mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy ≥120 <135 lm/Watt output . LM79 & LM80 Test report and all testing requiredfor LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C).
108Supplying, Installation, Testing & Commissioning of 200W Flood Light, powder coated pressure die cast aluminium body with built in or separate driver as per the requirement with Driver efficiency >85%, Input voltage: Input voltage: 140-270 Volt AC, frequency 50/60 hz, Operating temp range -5 0C to50 0C, internal surge protection of 5 KV L,N,E as per IEC 61000-4-5, Driver efficiency >85%,THD < 10% 53 DELHI SCHEDULE OF RATE (E&M) 2025 as per IEC 61000-3-2, P. F.≥0.95, IP-66,IK-10, CRI >70, under voltage and over voltage protection, EMI-EMC as per CISPR-15, lenses for beamangle 30 deg-120deg as per the application and the project requirement, suitable tilt able fitting, life time (LED, Driver & electrical circuitry) of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends as per LM80 extrapolation IES TM-21-11 report, CCT 3000°K / 4000°K / 5700°K /6500°K (As per ANSI Bin), SDCM(Standard Deviation Colour Matching) <5, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard complete in all respect i/c external connections with 1.5 sq.mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy ≥120 and <135 lm/Watt output . LM79 & LM80 Test reportand all testing required for LED fixtures as per BIS shall be submitted.. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C).
109Providing of rubber mat 1 mtr. Wide and min 3mm thick to withstand 15kV dielectric strength as per IS 15652 Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 56684054
AUTHORITY Local Bodies
TENDER VALUE 46.79 Lakhs
LAST DATE 05-08-2026
Authority
Authority Name Delhi Development Authority
Work Description Tender for maintenance of Various Sports Complexes. Sub Head : Running, Maintenance And Operation Of 11/0.415 Kv Sub-Station Equipments, Dg Set, Internal, External & High Mast Lighting, Submersible Pump, Fire Equipments, Air Conditioning, Water Cooler & Ro Units At Rohini Sport Complex Sec-14, Dda.
Basic Detail
Tender No 27/EE/ELD-2/DDA/2026-27
Bidding Type Tender
Location
City Delhi
State Delhi
Key Dates
Publish Date 27 Jul 2026
Submission Date 05 Aug 2026
Open Date 06 Aug 2026
Finance
Tender Value 46.79 Lakhs
Tender Fee Ref. Documents
EMD 93595
Exemption Not Available
Document List
5e40ae7b-4873-490f-9d5f-f8252be92492.html
BOQ_966125.xls
NIT27.pdf
Tendernotice_1.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Jul 27, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Aug 05, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 8 days
Aug 06, 2026

Bid Opening Date

Technical bids will be opened and evaluated.