Tender For Work Of Installing Aaac In Place Of Acsr Weasel Conductor In 11 Kv Line In Haripur Feeder From Devpura School To C Acola Haripur In Kaladungi Subdivision Under Electricity Distribution Division, Ramnagar..
Tender Value
Ref. Documents
Estimated cost
Bid Submission
10 Aug 2026
13 days left
EMD
3.72 Lakhs
Bank guarantee accepted
Document Fee
11800
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Nainital → Uttarakhand
EMD Exemption
Not Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender for Work Of Installing Aaac In Place Of Acsr Weasel Conductor In 11 Kv Line In Haripur Feeder From Devpura School To C Acola Haripur In Kaladungi Subdivision Under Electricity Distribution Division, Ramnagar..
BOQ
| Sl. No. | Item Description |
| 1 | Total amount of the \\"Rate Schedule\\" sheet Schedule of Quantity and Rate for Work of installing AAAC in place of ACSR Weasel Conductor in 11 KV line in Haripur Feeder from Devpura School to Campacola Haripur in Kaladungi Subdivision under Electricity Distribution Division, Ramnagar.. Against E-Tender Specification No. 42/EDC(H)/2026-27 Name of The Bidder's Firm: 0.0 Sl. No. Description of Work Unit Qty Rate Amount Part [A] (Supply Portion) |
| 2 | Bracing Clamp Top SP-55 with N/B |
| 3 | PP & CLAMP WITH N&B ST POLE SP-55 |
| 4 | Stay Clamp for SP-55 With Nut & Bolt |
| 5 | 11 KV CABLE TIES FOR PIN INSULATOR |
| 6 | 11 KV IPC FOR COVERED TO COVERED COND. |
| 7 | 11 KV IPC FOR COVERED TO BARE CONDUCTOR |
| 8 | 11 KV MID SPAN JOINTING KIT |
| 9 | IPC WITH AL. BAIL FOR EARTHING 11KV |
| 10 | 11KV Disc Insulator with Fitting B&S typ |
| 11 | DISC FITTING (B&S) TYPE 70KN 33KV AAAC |
| 12 | 11 KV Polymer Pin Insulator with Pin-D |
| 13 | 11KV AAAC COVERED COND. AL-59,99 SQ.MM. |
| 14 | 11 KV TENSION CLAMP WITH BAIL & IPC Total - Part [A] 0.0 Part [B] (Labour Portion) |
| 15 | Chemical Earthing:Earthing of distribution transformer including digging of pit of size 2.5 Mtr depth and make hole of size 150 mm. Placing of earthing electrode (to be supplied by contractor as per drawing No. A) as drawing B, connecting the same with G.I. Strip (to be supplied by contractor ) of size 35x6 mm as per drawing C for a minimum lenght 6 m. treatment of soil with highly condctive substance as per IS 30343 complete in all respect, result of earthing resistance to be recroded in M.B. before and after installation of earthing. The earth resistance after earthing should be less than 1 Ohm. |
| 16 | Fabrication of M.S. Channel Angle iron after cutting in required sizes with drilling of holes upto good finish for top channel, bracing and special type bracket etc. as per RESPO schedule and local approved drawing. |
| 17 | Excavation of earth for stay pit of size 0.6x0.6x1.2 mtr in all type of soil including proper dressing od sides and ramming of bottom including getting out the excavated soil and disposal of surplus excavated soil as directed complete work. |
| 18 | Erection of following Single support poles SP-55 in proper level and alignment along with fixing of all accessories. Like top channel & clamps as per RESPO construction Manual. |
| 19 | Muffing of Poles size 0.45cm x0.60 cm radious with cc1:3:6 (1 cement:3 coarse sand : 6 graded stone 10 mm nominal size) block and 45 cm height from ground level including cost of blast, cement and sand etc. |
| 20 | DISMANTLING OF 11 KV LINE(DOG) |
| 21 | Painting of SP-55 poles with angle and channel and all steel part by one cost of Rod Oxide Primer and two coats of aluminium Paint and two strip of fluorescent altemate Red and White paint 30 Cm wide upto 1.5 Mtrs. from ground level. |
| 22 | Providing and fixing of Danger board and number plates complete by providing clamps of MS Flat 50x6 mm and nuts & Bolts, danger board of MS Sheet 2 mm Thick 11\\"x7\\" size (Including cost of all material) |
| 23 | CARTAGE SP-55 POLE, 21-50 KM |
| 24 | CARTAGE OF PETTY MATERIAL,21-50 KM |
| 25 | HEADLOAD CARTAGE SP-55 POLE(0-1 KM) |
| 26 | HEADLOAD CARTAGE OF MATERIAL(0-1 KM) |
| 27 | BACK CARTAGE OF PETTY MATERIAL,0-20 KM |
| 28 | FIXING OF IPC WITH AL. BAIL FOR EARTHING |
| 29 | JUMPERING OF D/P TPMO, FUSE SET AND T/F |
| 30 | REALIGNMENT OF TILTED POLE |
| 31 | JUMPER SECTION POLE |
| 32 | FIXING OF 11KV 90KN TENSION CLAMP B&IPC |
| 33 | FIXING OF 11 KV MID SPAN JOINTING KIT |
| 34 | FIXING OF 11KV IPC FOR COVERED - COVERED |
| 35 | FIXING OF 11KV IPC COVERED TO BARE COND. |
| 36 | FIXING OF PP & CLAMP WITH N&B FOR SP-55 |
| 37 | FIXING OF DISC INS. FOR AAAC CONDUCTOR |
| 38 | SUPPLY & FIXING OF ANTI CLIMBING DEVICE |
| 39 | RENOZZELING OF EXISTING STAY SET |
| 40 | LAYING SPREADING,STRINGING AAAC CONDUCT. |
| 41 | 11 KV CABLE TIES FOR PIN INSULATOR |
| 42 | FIXING 11KV PIN INS. FOR AAAC CC Total - Part [B] 0.0 TOTAL [Part-(A) + Part (B)] 0.0 Place Date Superintending Engineer Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Jul 27, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedAug 10, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 13 daysAug 10, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 13 daysTender Documents
Download All (ZIP) ↓
Disclaimer