Tender For Construction Of Senior Advocates And Lady Advocates Lounge In Advocate Block-2 Building In The C Us Of New High Court Of Jharkhand, Dhurwa, Ranchi (High Court Pool)
Tender Value
52.61 Lakhs
Estimated cost
Bid Submission
03 Aug 2026
5 days left
EMD
1.05 Lakhs
Bank guarantee accepted
Document Fee
10000
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Ranchi → Jharkhand
EMD Exemption
Not Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender for Construction Of Senior Advocates And Lady Advocates Lounge In Advocate Block-2 Building In The C Us Of New High Court Of Jharkhand, Dhurwa, Ranchi (High Court Pool)
BOQ
| Sl. No. | Item Description |
| 1 | Dismantling R.C.C. work including stacking serviceable materials in countable stacks within 15M. Lead and disposal of unserviceable materials with all leads all complete as per direction of E/I. |
| 2 | Dismantling tile work in floors and roofs laid in cement mortar including stacking material within 50 metres lead.For thickness of tiles 10 mm to 25 mm |
| 3 | Dismantling plain cement or lime concrete work including stacking serviceable materials in countable stacks within 15M. Lead and disposal of unserviceable materials with all leads all complete as per direction of E/I. |
| 4 | Dismantling old plaster and pointing in cement or lime and raking out joints to 15mm depth, watering and disposal of unserviceable materials with all leads all complete as per direction of E/I. |
| 5 | Providing designation 125 mm thick reinforced designation 75A brick work in CM (1:4) in superstructure with approved quality of clean coarse sand of F.M. 2 to 25 including the cost of screening, carriage of materials, scaffolding , raking out joints to 15mm depth, curing, taxes and royalty (but excluding the cost of reinforcement) all complete as per building specification and direction of E/I. |
| 6 | Providing designation 75B one brick flat soling joints filled with local sand including cost of watering taxes royalty all complete as per building specification and direction of E/I. |
| 7 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 1:2:4 (1 cement : 2 coarse sand (zone-III) : 4 graded stone aggregate 20 mm nominal size) |
| 8 | Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement with 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) : 3 graded stone aggregate 20 mm nominal size). |
| 9 | Centering and shuttering including strutting, propping etc. and removal of form for Lintels, beams, plinth beams, girders, bressumers and cantilevers |
| 10 | Centering and shuttering including strutting, propping etc. and removal of form for Suspended floors, roofs, landings, balconies and access platform |
| 11 | Providing 12mm cement plaster (1:6) with clean coarse sand of F.M. 1.5 including screening, curing with all leads and lifts of water, scaffolding taxes and royalty all complete as per building specification and direction of E/I. |
| 12 | Providing and laying Vitrified tiles in floor in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS:15622, of approved brand &manufacturer, in all colours and shade, laid on 20 mm thick cement mortar 1:4 (1 cement: 4 coarse sand) jointing with grey cement slurry @3.3 kg/sqm including grouting the joints with white cement and matching pigments etc. The tiles must be cut with the zero chipping diamond cutter only . Laying of tiles will be done with the notch trowel, plier, wedge, clips of required thickness, leveling system and rubber mallet for placing the tiles gently and easily. |
| 13 | Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades, laid on 20 mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqm including grouting the joints with white cement and matching pigments etc., complete.Size of Tile 600x600 mm in Floor |
| 14 | Providing and fixing tiled false ceiling of specified materials of size 595x595 mm in true horizontal level, suspended on inter locking metal grid of hot dipped galvanized steel sections ( galvanized @ 120 grams/ sqm, both side inclusive) consisting of main “T” runner with suitably spaced joints to get required length and of size 24x38 mm made from 0.30 mm thick (minimum) sheet, spaced at 1200 mm center to center and cross “T” of size 24x25 mm made of 0.30 mm thick (minimum) sheet, 1200 mm long spaced between main “T” at 600 mm center to center to form a grid of 1200x600 mm and secondary cross “T” of length 600 mm and size 24x25 mm made of 0.30 mm thick (minimum) sheet to be interlocked at middle of the 1200x600 mm panel to form grids of 600x600 mm and wall angle of size 24x24x0.3 mm and laying false ceiling tiles of approved texture in the grid including, required cutting/making, opening for services like diffusers, grills, light fittings, fixtures, smoke detectors etc. Main “T” runners to be suspended from ceiling using GI slotted cleats of size 27 x 37 x 25 x1.6 mm fixed to ceiling with 12.5 mm dia and 50 mm long dash fasteners, 4 mm GI adjustable rods with galvanised butterfly level clips of size 85 x 30 x 0.8 mm spaced at 1200 mm center to center along main T, bottom exposed width of 24 mm of all T-sections shall be pre-painted with polyester paint, all complete for all heights as per specifications, drawings and as directed by Engineer-in-charge. |
| 15 | 12.5 mm thick square edge PVC Laminated Gypsum Tile of size 595x595 mm, made of Gypsum plasterboard, manufactured from natural gypsum as per IS 2095 part I and laminated with white 0.16 mm thick fire retardant PVC film on the face side and 12 micron metalized polyester on the back side with all edges sealed with the face side PVC film which goes around and wraps the edges and is bonded to the edges and the back side metalized polyester film so as to make the tile a completely sealed unit. |
| 16 | Extra for cleaning the old surface by scrapping the entire old white wash or colour wash including cost of scaffolding all complete as per direction of E/I. |
| 17 | Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete |
| 18 | Providing two coats of plastic emulsion paint of approved shade and make over a coat of cement primer over new surface including preparing plastered surface by rubbing smooth with pumice stone or fine sand paper, applying putty wherever required, scaffolding washing of floor and taxes all complete as per building specification and direction of E/I. |
| 19 | Providing two coats of plastic emulsion paint of approved shade and make over old surface including washing cleaning and preparing the walls scaffolding washing of floor and taxes all complete as per building specification and direction of E/I. |
| 20 | Providing two coats of synthetic enamel paint of apporoved shade and make over steel surface thoroughly scaffolding and taxes all complete as per building specification and direction of E/I. |
| 21 | Providing Tor steel reinforcement of 8mm dia rods as per approved design and drawing exclusive carriage of M.S. bars to work site, cutting, bending and binding with annealed wire with cost of the wire, removal of rust, placing the rods in position all complete as per building specification and direction of E/I. TMT Fe 500 (only valid for SAIL & TATA STEEL) |
| 22 | Providing Tor steel reinforcement of 10mm. ,12mm & 16mm dia. bars as per approved design and drawing with cutting, bending and binding with annealed wire with cost of wire, removal of rust placing the rods in position all complete as per building specification and direction of E/l. 10mm TMT Fe 500 ( Only valid for Tata (Tiscon), SAIL, JSPL, Electrosteel Steels Ltd.. Bokaro, and Vizag (RINL). |
| 23 | Providing and fixing factory made uPVC glazed/wire mesh windows/ doors comprising of lead free uPVC multi chambered frame, sash and mullion/coupler (where ever required) extruded profiles having minimum wall thickness of 1.70 mm for Series R1 and R2 profiles and 2.10 mm for Series R3 and R4 profiles conforming to EN: 12608 in any shape, colour and design duly reinforced with galvanized mild steel section made of required shape & size as per CPWD Specification, uPVC extruded glazing beads, interlocks and Inline sash adaptor (where ever required) of appropriate dimension, EPDM gasket, hardware, SS 304 grade fasteners of minimum 8 mm dia with countersunk head, comprising of matching polyamide PA6 grade sleeve for fixing frame to finished wall as per IS 1367 : Part 1 to 14, plastic packers, plastic caps and necessary stainless steel screws etc. Profile of frame, sash & mullion (if required) shall be mitred cut and fusion welded/mechanically jointed duly sealed at all corners, including drilling of holes for fixing hardware and drainage of water etc. After fixing frame the gap between frame and adjacent finished wall shall be filled with weather proof silicon sealant over backer rod of approved size and quality, all complete as per approved drawing conforming to CPWD specification & direction of Engineer-in-Charge. Section of steel reinforcement and cross sections of uPVC profiles to be as per design approved by Engineer-in-Charge. Wire mesh / Glazing of plain/ toughened/ laminated/ double glass unit with / without high performance coatings as per design requirements and conforming to IS: 3548 & IS: 16231 shall be paid separately. Note:- Structural design proof checked from a Government Engineering Institute, to be provided by the manufacturer for (i) Sites with basic wind speed > 45 m/sec as per IS 875 — Part 3 (ii) Sites with structure height more than 20m for all wind speeds |
| 24 | Fixed window / ventilator with mullion / transom.Using R3 series with frame (55 mm & above ) x (45 mm & above) & mullion (55 mm & above) x (65 mm & above). (Height upto 2.5 metre) |
| 25 | Casement door single panel with zinc alloy (zamak) 3D hinges, multi-point locking system with cylinder, zinc alloy (zamak) powder coated handles on both sides. |
| 26 | Using R3 series with frame (55 mm & above) x (50 mm & above) & sash (55 mm & above) x (85 mm & above) (Height upto 2.5 metre). |
| 27 | Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of engineer-in-charge . (Cost of aluminium snap beading shall be paid in basic item): |
| 28 | With float glass panes of 5 mm thickness (weight not less than 12.50 kg/sqm) |
| 29 | Providing and fixing, in position concealed G.I. section for wall paneling using board of required thickness fixed on the 'W' profile (0.55 mm thick) having a knurled web of 51.55 mm and two flanges of 26 mm each with lips of 10.55 mm, placed @ 6 1 0 mm CIC in perimeter channel having one flange of 20 mm and another flange of 30 mm with thickness of 0.55 mm and web of length 27 mm. Perimeter channel is fixed on the floor and the ceiling with the nylon sleeves@610 mm CIC with fully threadedself-tapping dry wall screws. Board is fixed to the 'W' profile with 25 mm countersunk ribbed head screws @ 200 mm CIC., all complete as per the drawing & directions of engineer-in-charge, the joints of the boards are finished with specially formulated jointing compound and 48 mm wide jointing tape to provide seamless finish. |
| 30 | Multipurpose cement board reinforced with suitable fibrecement screw. 8 mm thick cement fibre board, Type- B,Category- I l l as per IS: 14862 : 2000 |
| 31 | Providing and fixing 150 mm bright finished floor brass door stopper with rubber cushion, necessary brass screws etc. to suit shutter thickness complete |
| 32 | Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal110 mm diameter |
| 33 | Providing and fixing on wall face unplasticised - PVC moulded fittings/accessories for unplasticised Rigid PVC rain water pipes conforming to IS 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion. |
| 34 | Single tee with door 110x110x110 mm |
| 35 | Single tee without door 110x110x110 mm |
| 36 | Bend-110mm |
| 37 | Shoe-110mm |
| 38 | Providing and fixing unplasticised -PVC pipe clips of approved design to unplasticised - PVC rain water pipes by means of 50x50x50 mm hard wood plugs, screwed with M.S. screws of required length, including cutting brick work and fixing in cement mortar 1:4 (1 cement : 4 coarse sand) and making good the wall etc. complete.PVC Clip 110 mm |
| 39 | Providing and fixing P.V.C. waste pipe for sink or wash basin including P.V.C. waste fittings complete. |
| 40 | Semi rigid pipe32 mm dia |
| 41 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply and all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge.Concealed work, including cutting chases and making good the walls etc.20mm dia |
| 42 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge.External work25mm dia |
| 43 | Providing and fixing C.P. Brass extension nipple (size 15 mm x 50 mm) of approved make and quality as per direction of Engineer-in-charge. |
| 44 | Supplying, materrials and labour for constructing inspection chamber of designation class 75B brick size 750mm deep, 600X450mm internal dimension having 250mm wall thickness in cement mortar (1:6) including 12mm cement plaster (1:4) with punning on inside and cement plaster (1:6) with 600X475mm G.I. cover with frame (weight not less than 35kg) alongwith earth work in excavation and 80mm thick PCC (1:3:6) in foundation and refilling all complete as per specification and direction of E/I. |
| 45 | Providing and fixing one piece construction white vitreous china squatting plate with an integral longitudinal flushing pipe, white P.V.C. automatic flushing cistern, with fittings, standard size G.I. / PVC flush pipe for back and front flush with standard spreader pipes with fittings, G.I clamps and C.P. brass coupling complete, including painting of fittings and cutting and making good the walls and floors etc. wherever required : |
| 46 | Single squatting plate with 5 litre P.V.C. automatic flushing cistern |
| 47 | ELECRTICAL |
| 48 | Point wiring in PVC conduit, with modular type switch :- Wiring for light point/fan point/exhaust fan point/call bell point with 1.5 sq.mm FR PVC insulated copper conductor single core in surface/recessed PVC conduit, with modular switch, modular plate suitable GI box etc as required |
| 49 | Group C |
| 50 | Power plug wiring in PVC conduit (2 x 4 sq. mm) :- |
| 51 | Wiring for light/power plug with 2 x 4 sq.mm FR PVC insulated copper conductor single core cable in surface/recessed PVC conduit, along with 1 No 4 sq.mm FR PVC insulated copper conductor single core cable for loop earthing etc as required. |
| 52 | Circuit/ submain wiring in PVC conduit :- |
| 53 | Wiring for circuit/ submain wiring along with earh wire with the following sizes of FR PVC insulated copper conductor single core cable in surface / recessed PVC conduit as required |
| 54 | 2 x 1.5 sq.mm + 1 x 1.5 sq.mm earth wire |
| 55 | 2 x 2.5 sq.mm + 1 x 2.5 sq.mm earth wire |
| 56 | S/F PVC conduit :- |
| 57 | Supplying and fixing of following sizes of PVC conduit along with accessories in surface / recess including cutting the wall and making good the same in case of recessed conduit as required. |
| 58 | 20 mm |
| 59 | 25 mm |
| 60 | S/F Modular type switch/ socket :- |
| 61 | Supplying and fixing of following modular switch / soket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. |
| 62 | 5/6 amps, one way switch |
| 63 | 5/ 6 amps, two way switch |
| 64 | 15/ 16 amps, one way switch |
| 65 | 5/6 amps, 3 pin socket outlet |
| 66 | 15/16 amps, 6 pin socket outlet |
| 67 | S/F Modular type electronic fan regulator :- |
| 68 | Supplying and fixing stepped type electronic fan regulator on the existing modular plate & switch box including connections but excluding modular plate etc. as required. |
| 69 | S/F Modular type blanking plate :- |
| 70 | Supplying and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as required. |
| 71 | S/F Modular boxes, base & cover plate :- |
| 72 | Supplying and fixing following size / modules , GI box along with modular base & cover plate for modular switches in recess etc as required. |
| 73 | 4/5 module (78mm x 140mm x 50mm) |
| 74 | 6 module (78mm x 205mm x 50mm) |
| 75 | 8/9 module (78mm x 230mm x 60mm) |
| 76 | 12 module (135mm x 205mm x 60mm) |
| 77 | S/F light plug point with modular type accessories :- |
| 78 | Supplying and fixing suitable GI box with modular plac and cover in front on surface of in recess, including providing and fixing 3 pin 5/6 amps modular socket outlet and 5/6 amps modular switch. connection, painting etc. as required (For light plugs to be used in non residential buildings) |
| 79 | S/F power plug point with modular type accessories :- |
| 80 | Supplying and fixing suitable GI box with modular plac and cover in front on surface of in recess, including providing and fixing 6 pin 15/16 amps modular socket outlet and 5/6 amps modular switch. connection, painting etc. as required (For light plugs to be used in non residential buildings) |
| 81 | S/F ceiling rose :- |
| 82 | Supplying and fixing 2 pin 5 amp. Ceiling rose on the existing junction box/ wooen block including connection etc. as required . |
| 83 | ITC fluorescent fitting directly on surface :- |
| 84 | Installation testing and commissioning of pre-wired, fluorescent fitting ./ compact fluorescent fitting of all types, complete with all accessories and tube etc. directly / wall. including connection with 1.5 aq.mm FR PVC insulated . copper conductor single core cable and earthing etc. as required . |
| 85 | ITC fluorescent fitting with down rods:- |
| 86 | Installation testing and commissioning of pre-wired, fluorescent fitting ./ compact fluorescent fitting of all types, complete with all accessories and tube etc. including supplying and fixing ball and socket arrangement 2 no. down rods of 20mm dia x 1.6 mm thick steel conduit/GI pipe upto 30 cm length. , painting and wiring the down and connection with 1.5 sq.mm PVC insulated, copper conductor, single core cable and earthing etc. as required |
| 87 | S/F Extra down rod :- |
| 88 | Providing and fixing extra conduit down rod of 20mm dia 2 x 10cm length wiring with 2 x 1.5mm FR PVC insulated , copper conductor. Single core cable including painting etc. as required .(Note then 5 cm length shall be rounded to the nearest 10 cm and 5 cm of less shall be ignored |
| 89 | ITC ceiling fan :- |
| 90 | Installation, testing and commissioning of ceiling fan, including wiring the down rods of standard length (upto 30 cm) with 1.5 sq.mm FR PVC insulated, copper conductor, single core cable etc. as required. |
| 91 | ITC exhaust fan upto 450 mm. sweep :- |
| 92 | Installation of exhaust fan upto 450mm sweep in the existing opening , including making the hole to suit the size of the above fan, making good the damage, connection , testing , commissioning etc . as required |
| 93 | 2' x 2' LED Panel light |
| 94 | Supply Installation, testing and commissioning of follwing size ceiling fan 3 Blades confirming to IS:374:2019 including wiring the down rods of standard length (upto 30cm) with 1.5sq.mm. FR PVC insulated, copper wire suitable for 230V 50Hz, single phase supply etc. complete as required. |
| 95 | 1200mm (48\\") BLDC 5star rating 32W Ceiling Fan |
| 96 | 12'' (300mm) metal exaust fan . |
| 97 | Carriage of materials from source to site work including loading & unloading all complete job as per specification and direction of E/I |
| 98 | Sand 10km |
| 99 | Stone Chips 22km |
| 100 | Bricks 8km |
| 101 | Providing Fitting & Fixing Door Closer all taxes and labour complete as per building specification and direction of E/I. |
| 102 | Supplying, Fitting & Fixing of Roller Blinds all taxes and labour complete as per building specification and direction of E/I. |
| 103 | Supplying, Fitting & Fixing of Mirror all taxes and labour complete as per building specification and direction of E/I. |
| 104 | Providing and fixing Connection Pipe With Nuts all taxes and labour complete as per building specification and direction of E/I. |
| 105 | Providing and fixing Angular stop Cock all taxes and labour complete as per building specification and direction of E/I.15 mm nominal bore |
| 106 | Providing and fixing EWC (water closet) complete in all respect as per directions of Engineer-in-Charge. |
| 107 | Providing and Fixing Wash Basins With padestal all taxes and labour complete as per building specification and direction of E/I. |
| 108 | Supplying, fitting & fixing Two Way Bib Cock all taxes and labour complete as per building specification and direction of E/I. |
| 109 | Supplying, fitting & fixing Health Faucet all taxes and labour complete as per building specification and direction of E/I. |
| 110 | Supplying, fitting & fixing Bib Cock with Flange all taxes and labour complete as per building specification and direction of E/I. |
| 111 | Supplying, fitting & fixing of BRASS WASH BASIN COUPLING all taxes and labour complete as per building specification and direction of E/I. |
| 112 | Supplying, fitting & fixing Concealed Cistern all taxes and labour complete as per building specification and direction of E/I. |
| 113 | Supplying, fitting & fixing Bib Tap all taxes and labour complete as per building specification and direction of E/I. |
| 114 | Supplying, fitting & fixing Towel Ring all taxes and labour complete as per building specification and direction of E/I. |
| 115 | Supplying, fitting & fixing Waste Jali all taxes and labour complete as per building specification and direction of E/I. |
| 116 | Supplying, fitting & fixing Soap dispenser all taxes and labour complete as per building specification and direction of E/I. |
| 117 | Providing and fixing Urinal all taxes and labour complete as per building specification and direction of E/I. |
| 118 | Providing and fixing Urinal partition with frosted -Glass 10mm With all taxes and labour complete as per building specification and direction of E/I. |
| 119 | Providing and fixing Concealed Flush Valve all taxes and labour complete as per building specification and direction of E/I. |
| 120 | Supplying and Fixing of Hand dryer in white all complete as per specification and direction of E/I |
| 121 | Supplying, fitting & fixing Toilet Paper holder all complete as per specification and direction of E/I |
| 122 | Supplying, fitting & fixing Kent all complete as per specification and direction of E/I |
| 123 | Add 18 % GST (in Basic Rate must fill 12) |
| 124 | Add 1% Labour Cess (in Basic Rate must fill 1) Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Jul 27, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedAug 03, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 5 daysAug 04, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 6 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender