Tender For Repair And Refurbishment Of Tahasil Office At Kashinagar In The District Of Gajapati Buildings.
Tender Value
33.53 Lakhs
Estimated cost
Bid Submission
10 Aug 2026
7 days left
EMD
33600
Bank guarantee accepted
Document Fee
6000
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Gajapati → Odisha
EMD Exemption
Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender for Repair And Refurbishment Of Tahasil Office At Kashinagar In The District Of Gajapati Buildings.
BOQ
| Sl. No. | Item Description |
| 1 | Fly ash brick masonry in cement mortar (1:6) in Super structure using Fly ash bricks of (23x11x8cm) size having a crushing strength of not less than 75 kg per Sq.cm with dimensional tolerance + 8 percent after immersing Bricks in water till saturation before use , including splays cutting, circular molding, chamfering, corbelling and all similar type of operations with all necessary projections watering, curing etc. complete including cost, conveyance, royalties, of all materials, cost of all labour, labour CESS T&P ,Scaffolding as required etc. complete in all respect as drawing and technical specifications and as per directed by the Engineer-in-charge.2nd Floor |
| 2 | R.C.C. work with M-20 grade In Different RCC Works having minimum compressive strength in work test of 200 Kg/Cm² in 15cm cubes at 28 days after mixing and texts conducted in accordance with relevance IS code using 20 mm and downgraded size black hard granite crusher broken stone chips and screened and washed sharp river sand of approved quality and from approved quarry including hoisting lowering and laying concrete and compacting by using vibrator, watering, curing for 28 days, including cost of centering & shuttering and finishing the exposed surface smooth providing grooves or beads where necessary including cost, conveyance, royalty, Addl charg, DMF & EMF of all materials , cost of all labour, labour CESS T&P etc. required for complete the work in all respect but excluding cost and conveyance of M.S. rods or Tor steel & binding wires and labour charges for strengthening, cutting, bending grills and placing in proper position as per the direction of the Engineer-in-Charge.2nd FloorRCC Column in Super Structure |
| 3 | RCC Roof Beams (2nd Floor) |
| 4 | RCC Lintel (2nd Floor) |
| 5 | RCC Chajja (1st Floor) |
| 6 | RCC Chajja (2nd Floor) |
| 7 | RCC Roof Slab (2nd Floor) |
| 8 | Supplying, fitting and placing uncoated SeQR TMT bar reinforcement including straightening bent up or coiled rods, cutting, bending, cranking, hooking, welding or jointing (if required) and binding, tying and placing in proper position as required for RCC works including cost, conveyance of steel and binding wires of 18 to 20 gauge and cost of all labour, labour CESS T&P etc. required for complete the work in all respect as per drawing and technical specification and directed by the Engineer-in-charge. (Weight of reinforcement shall be calculated on the basis of IS 1732, wastage ,overlaps, couplings, welded joints ,spacer bars, chairs, stays, and annealed steel wire or other method of binding &placing shall not be considered for payment).(2nd Floor) |
| 9 | Providing 12 mm thick cement plaster with cement mortar (1:6) with screened and washed sharp river sand for mortar and finished smooth to the rough surface of walls after racking out joints including watering and curing, rounding of corners, providing grooves where ever necessary with cost, conveyance, royalties of all materials, cost of all labour, Labour CESS,T&P, and scaffolding as required to complete the work in all respect as per the Direction of the Engineer-in-charge .(Gound Floor) |
| 10 | (1st Floor) |
| 11 | (2nd Floor) |
| 12 | Providing 16 mm thick cement plaster with cement mortar (1:6) with screened and washed sharp river sand for mortar and finished smooth to the rough surface of walls after racking out joints including watering and curing, rounding of corners, providing grooves where ever necessary with cost, conveyance, royalties of all materials, cost of all labour, Labour CESS,T&P, and scaffolding as required to complete the work in all respect as per the Direction of the Engineer-in-charge .(Gound Floor) |
| 13 | (2nd Floor) |
| 14 | Providing 6mm. thick cement plaster in cement mortar (1:4) to RCC surfaces finished smooth including closed deep chipping and slurry treatment using good quality screened and washed river sand, including watering and curing, rounding of corners, providing grooves where ever necessary with cost, conveyance, royalties of all materials, cost of all labour, labour CESS,T&P, and scaffolding as required to complete the work in all respect as per the Direction of the Engineer-in-charge .(1st Floor) |
| 15 | (2nd Floor) |
| 16 | Removing grading plaster from roof slab including stacking the useful materials for reuse and removing the debris with in 50m lead including cost of all labour, Labour CESS and T&P. etc required to complete the work in all respect, as per direction of Engineer-in-charge. |
| 17 | Providing and laying 4 cm thick Grading Concrete over roof slab with cement concrete (1:2:4) using 12mm size black hard granite crusher broken chips and screened & washed sharp river sand of approved quality from approved quarry and finished smooth, including watering and curing for the required period including cost, conveyance, royalties of all materials, cost of all labour, labour CESS, T&P etc. required to complete the work in all respect as per direction of the Engineer-in-Charge. |
| 18 | Distempering two coats with approved quality and shade from a recognized company to give an even shade including preparation of the surface before applying , including cost of scaffolding staging and cost ,conveyance of all materials ,cost of all labour, labour CESS and T&P required to complete the work in all respect as per specification and direction of the Engineer-in-charge.(Ground Floor) |
| 19 | (1st Floor) |
| 20 | (2nd Floor) |
| 21 | Providing and Painting the surface of the walls with one coat of wall primer(water based) of approved quality after cleaning the plastered surface perfectly by watering and brushing including cost , conveyance of all material, brushes, all labour, scaffolding, T&P etc. required to complete the work in all respect as per specification and direction of the engineer-in-charge.(Ground Floor) |
| 22 | (1st Floor) |
| 23 | (2nd Floor) |
| 24 | Providing and Finishing surfaces of walls & ceiling with cement based wall putty [ water based ] of approved make and finished smooth and even surface to receive painting including cost of scaffolding ,staging and cost , conveyance of all the materials ,including cost of all labour, labour CESS and T&P required to complete the work in all respect as per specification and direction of the Engineer-in-charge.(Ground Floor) |
| 25 | (1st Floor) |
| 26 | Providing & painting exterior surfaces of walls with two coats of Weather seal coat paint of approved quality and shade from a recognized company to give an even shade, after cleaning the plastered surface perfectly by watering and brushing including cost of scaffolding ,staging and cost ,conveyance of all materials ,all labour, labour CESS and T&P required to complete the work in all respect as per specification and direction of the Engineer-in-charge.(Ground Floor) |
| 27 | (1st Floor) |
| 28 | (2nd Floor) |
| 29 | Finishing interior surfaces of walls with two coats of Plastic emulsion paint of approved quality and shade from a recognized company to give an even shade including preparation of the surface before applying , including cost of scaffolding ,staging and cost ,conveyance of all materials ,cost of all labour, labour CESS and T&P required to complete the work in all respect as per specification and direction of the Engineer-in-charge. |
| 30 | Providing ,Supplying fitting and fixing of Polished Vitrified floor tiles of premium grade having thickness 8mm to 10mm confirming to IS 15622:2006 (Group-B la) of size 600mm x 600mm, Plain Ivory, in floors and treads on steps and landing on 20mm thick bed of cement mortar 1:4(1 cement : 4 screened and washed river sand ) jointed with neat white cement mixed with pigment to match he shades of the tiles ,curing for required days , including cost of pre cast tiles , cost , conveyance , royalty of all materials, cost of all labour , labour CESS and T&P required to complete the work in all respect as per specification and direction of Engineer-in-charge.(Ground Floor) |
| 31 | (2nd Floor) |
| 32 | Providing ,Supplying fitting and fixing of Polished Vitrified tiles of premium grade having thickness 8mm to 10mm confirming to IS 15622:2006 (Group-B la) of size 600mm x 600mm . Plain Ivory, in Dados skirting and rises of steps on 12mm thick cement plaster 1:3 (1 cement :3 screened and washed river sand) jointed with neat cement slurry mixed with pigment to match the shade of the tiles , ,curing for required days , including cost of pre cast tiles , cost , conveyance , royalty of all materials, cost of all labour , labour CESS and T&P required to complete the work in all respect as per specification and direction of Engineer-in-charge.(2nd Floor) |
| 33 | Supplying. fitting and fixing of openable UPVC doors with door frame of approved make with 6mm thick glass of approved quality complete with frame, shutters and all fitting and fixtures. etc. complete in all respect as per direction of the Engineer-in-charge. |
| 34 | Supplying and fitting-fixing of Un-plasticised Poly Vinyl Chloride (UPVC) (FENESTA/NCL VEKA LTD) Two Track. Two panel sliding window -60-Series duly manufactured using UPVC reinforced profiles of 108mm x 45mm x 2.5mm for outer frames and window sash of 39mm x58 mm x2.5mm capable of mounting single glazing system, structurally reinforced with hot dip galvanized up to 50 microns of minimum thickness of 1.5 mm prefabricated & welded through fusion welding the window frame shall be fitted with 6mm thick clear toughened glass of SAINT-GOBAIN make duly fixed with EPDM weathering seal resistant and the system is to be installed using Reinforced Large Coupler at the site using anchor fasteners, silicon rubber sealant, easy glazing / deglazing at site etc. including cost and conveyance of all materials, accessories, labour charges, materials and product conforming to ASTM D 638-14,EN-477-95 and other applicable codes and standards as per direction of the Engineer-in-Charge. |
| 35 | Supplying, fitting and fixing of 32mm thick flush door shutter with approved quality of 30mm thick BWR block board pasted with 1mm thick sunmica on both side of approved design and quality including cost of all door fittings and fixtures etc. complete in all respect in all floors as directed by the Engineer-In-Charge. |
| 36 | Supplying, fitting and fixing M.S. grill gate /Doors/Windows out of M.S. flat confirming to IS -1977/1996 as per the design approved @35kg/sqm etc including cost,conveyance of all materials,priming,and labour for fitting fixing etc .complete as per the instruction of Engineer in-Charge.(Ground Floor) Door |
| 37 | (1st Floor) Window |
| 38 | (2nd Floor) Window |
| 39 | (2nd Floor) Door |
| 40 | Painting 2 (Two) coats with synthetic enamel paint to iron work over a coat of primer of approved colour, shade after sand papering , polishing the surface including cost, conveyance of all materials, all labour, labour CESS T&P , scaffolding etc. required to complete the work in all respect as per drawing and technical specification and direction of Engineer-in-Charge.(Ground Floor) |
| 41 | (1st Floor) |
| 42 | (2nd Floor) |
| 43 | Providing fitting and fixing up wall panneling OEL aluminium anodised section No-9210 and 9207 as single groove and double groove respectively as horizontal and vertical member and OEL section 4660 as tapered clip for fixing up 12 mm thick prelaminated board and jointing angle No-1855 etc with 6 liver mortise lock, including cost carriage of all materials [excluding cost of black glass & prelaminated particle board ], including cost of all labour, labour CESS , hire and running charges of drill machine , T&P etc. required to complete the work in all respect as per specification and direction of the Engineer-in-charge. |
| 44 | 'Workstation U type (Size)13 f t x 12 ft x 2.5 ft .Supplying and fixing of 19mm Ply prefereably (century,green,alishan with ISI certification with .laminated with sunmica,assembled with 3 rack drawer and keyboard,CPU & UPS Stand. |
| 45 | Providing fitting and fixing of Door closer etc.complete |
| 46 | Supplying and fixing of Roller blinds by fixing powder coated top channel, bottom channel with bottom end cap, control unit and good quality of 0.60 mm thick fabric of approved design and quality etc. complete the work in all respect as per direction of Engineer in Charge. |
| 47 | E.I. WorksRecessed wiring to light point/Fan point/ Exhaust fan point/Call bell point with 1.5sq.mm FR PVC insulated single core multistrand copper conductor of ISI marked with 20mm dia non-metallic PVC flexible conduit with 6Amp ,250V Modular switch (make-Anchor/ Legrand /Roma/Equivalent)ISI marked and ceiling rose ISI marked mounted on Metal box having front Modular cover of suitable size, Metal box with 1.5sq.mm FR PVC insulated single core multistrand copper conductor as earth wire including all accessories and connection (Make of wire-Finolex/L&T/Anchor/Havells/V-Guard/KEI/RHINO/C&S) Group-A -L.P- 35 F.P- 3 C.B.P- |
| 48 | Group-B L.P- 23 F.P-15 C.B.P- |
| 49 | Group-C L.P- 12 F.P- C.B.P-2 |
| 50 | Wiring for twin control light point / Group Control with 1.5 sq.mm FR PVC insulated single core multistrand copper conductor of ISI marked in recess PVC conduit with 2 way Modular type switch, Modular plate, suitable GI Box and earthing point with 1.5 sq.mm FR PVC insulated single core multistrand |
| 51 | Supply and fixing of 6Amp plug with 6Amp switch on existing board (Modular type )(make-Anchor/ Legrand /Roma/Equivalent) |
| 52 | Supply and fixing of Modular metal box on surface or in recess with suitable size of Modular cover in front including providing and fixing 1 nos of 6pin 15/16Amp socket outlet and 1 nos of 15/16Amp Modular switches connection (make-Anchor/ Legrand /Roma/Equivalent) |
| 53 | S/F of Multipurpose board Supply and fixing of 2 no.sof 3pin 5/6 amp modular socket and 2 nos of S.P. 5/6 amp one way modular switch on Modular G.I. Box with Modular Base and cover. (make-Anchor/ Legrand /Roma/Equivalent) |
| 54 | Supply and fixing of 4 no.s of 3pin 5/6 amp modular socket and 3 nos of S.P. 5/6 amp one way modular switch, on Modular G.I. Box with Modular Base and cover. (make-Anchor/ Legrand /Roma/Equivalent) |
| 55 | Supply and drawing of following size PVC insulated single core multistrand copper conductor in existing surface/recessed/STEEL / conduit as required.1 X 1.5sqmm |
| 56 | Recessed submain wiring alongwith earth wire with the following sizes of PVC insulated single core multistrand copper conductor ISI marked conforming to IS-694/1990 in 20mm dia non metallic heavy duty flexible conduit 1.6 mm in surface /recessed PVC conduit as required (make of wire -Finolex/L&T/Anchor/Havells/V-Guard/KEI/RHINO)2 X 2.5sq.mm +1 X 1.5sqmm |
| 57 | 2 X 4sq.mm +1 X 1.5sqmm. |
| 58 | 2 X 6sq.mm +1 X 2.5sqmm. |
| 59 | Supply and fixing of superior type call bell of ISI marked, on 6\\" X 4\\"conforming to IS-2268/1994 and bell push of ISI marked , conforming to IS-1293/ 1988 (make-Cona/ Anchor/equivalent)Musical Call bell with battery |
| 60 | Supply and fixing of different type of fitting with lamp S/F of 9Watt LED bulb fitting (Make-Havells/Philips/C&S/Magik/Crompton/Halonix) |
| 61 | S/F of Bakelite angle holder/batten holder of ISI marked conforming to IS-1258/1987 in place of ceiling rose . |
| 62 | S/F of 20W 4' LED fitting Surface LED Light fitting (Make-Havells/Philips/C&S/Magik/Crompton/Halonix) |
| 63 | S/F of 15Watt Circular Surface down light LED fitting (Make-Havells/Philips/C&S/Magik/Crompton/Halonix) |
| 64 | S/F of 36W 2'X2' LED Surface/ recessed on Ceiling LED fitting (Make-Havells/Philips/C&S/Magik/Crompton/Halonix) |
| 65 | S/F of 90W LED street light fitting (Make-Havells/Philips/C&S/Magik/Crompton/Halonix) |
| 66 | S/F of G.I. Street light Bracket with M.S. Clamp |
| 67 | Supply and fixing of fan (make-Usha/Orient/V-Guard/Khaitan/Havells/Crompton/Almonard/V-Guard)S/F of 1200mm High speed Ceiling fan, Heavy Duty,durable, copper winding,Aluminium blade(ISI mark)Crompton Grave/Khaitan/Orient/Polycab/Bajaj/V-Guard |
| 68 | Exhaust fan 300mm (12\\") size With Making hole requir size.(Make-Havels/Ushs/Almonard/Orient/Cromoton/ or Equivalent) |
| 69 | Supply and fixing of Modular fan regulator(Cona/ Anchor/ Usha/Bajaj)Electronics step type Regulator (Modular type) |
| 70 | Supply and fixing of 5Amp to 32A rating 240V \\"B\\" series MCB suitable for lighting and other loads of the following poles in the exiting MCB DB ISI marked complete with connections testing and commissioning etc. as required.(make-HPL/ Havells/ Legrand /L&T/C&S)6 to 32 Amp rating Single pole (SP) MCB |
| 71 | 0.5 to 5 amp rating Single pole (SP) MCB |
| 72 | Supply and fixing of following rating Double Pole 240V \\"C\\" series MCB suitable for lighting and other loads of the following poles in the exiting MCB DB ISI marked complete with connections testing and commissioning etc. as required.(make-HPL/ Havells/ Legrand /L&T/C&S)40 Amp DP MCB ISOLATOR |
| 73 | 63Amp DP MCB ISOLATOR |
| 74 | S/F of 20 to 32 amp 240 V , DP AC Starter on surface or in recess with complete connections, testing and commissionig etc. as required. |
| 75 | Supply and fixing of following way single pole and neutral sheet steel MCB distribution board 250V on surface/recess complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, detachable gland plate, interconnections, phosphatized and powder painted including earthing etc. as required (but with out MCB/ RCCB/ Isolator) make-HPL/ Havells/ Legrand /L&T/C&S.)8 WAY, DOUBLE DOOR |
| 76 | 10 WAY, DOUBLE DOOR |
| 77 | Supplying and fixing of following MODULAR type switch / socket on the existing switch box / cover including connections etc as required6 Pin 15/16 Amp Modular socket outlet |
| 78 | 6 Pin 15/16 Amp Modular TOP |
| 79 | Blank plate |
| 80 | Supplying and fixing of following MODULAR type Bell push on the existing switch box / cover including connections etc as required. |
| 81 | Supply and fixing of 4pole MCCB in cubicle pannel board S/F of 63 to 100 AMP 25KA MCCB of Hager/Legrand/C&S Make with MS box including both side connections with all complete |
| 82 | Supply and fixing of copper bus bar with suitable sheet metal enclosure on MS angle frame with proper grouting on wall including all connections. 63Amp TPN bus bar -300 X 25 X 3mm size |
| 83 | Supply of PVC/XLPE Aluminium armored cables ISI marked.(Make- Glowstar/ Polycab/Nicco/KEI/RHINO as per letter No-309 19.1.2011 of SEEC (R&B) Odisha)25sq.mm 3 1/2 core |
| 84 | Cable laying Cable laying on wall surface with steel shaddle upto 25sqmm |
| 85 | Supply and fixing Earthing with G.I earth pipe 3mtr. Long 40mm dia ISI marked including accessories and providing masonary enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal and salt as required Providing and fixing 8 SWG (4 mm) dia copper wire on surface or in recess for loop earthing as required |
| 86 | Supply and fixing of copper plate earthing( 600 X 600 X 3.15mm )with running copper flat 25 X 5mm from copper plate to funnel of 40mm dia G.I pipe including all accessories |
| 87 | Supply , installation , testing and commissioning IN DOOR /OUT DOOR pannel board with danger board 16 SWG pannel box 30 X 30X 10=9000sq. inch for single door made out of CR sheet of 16SWG and boarder angle frame to provide above pannel with proper space ,hinges, and other accessories , hinged door must be painted one coated red oxide and two coat enamel gray paint (Duly Powder Coated) |
| 88 | Supply and fixing of internal wiring to equipment installed in the pannel board with required size of copper multistrand single core cables duly crimped with copper lugs and all connections 30\\" X 30\\"=900Sqinche including cost of copper conductor and other fittings |
| 89 | Supply and fixing of Indicator lamp with toggler switch and fuse |
| 90 | Supply and fixing of C.T coil upto 400Amp including all connections |
| 91 | Supply and fixing of Digital Ammeter with selector switch including all connections |
| 92 | Supply and fixing of Digital voltmeter with selector switch including all connections |
| 93 | S/F of copper bus bar 35 x 5mm with required size of insulating material and nut and bolts |
| 94 | installation , testing , commissioning & Charging of pannel board |
| 95 | Supply and fixing of 4 pole MCCB in existing cubicle panel board including drilling holes in cubcle panel, making connections, etc. as required.63 Amp 16KA |
| 96 | 200 Amp 16 KA |
| 97 | Supply and fixing of changeover switch (Anchor/ Havells/ Apex)200Amp three pole neutral |
| 98 | Supply and fixing of following rating Double Pole 240V \\"C\\" series MCB suitable for lighting and other loads of the following poles in the exiting MCB DB ISI marked complete with connections testing and commissioning etc. as required.(make-HPL/ Havells/ Legrand /L&T/C&S)40 Amp DP MCB ISOLATOR |
| 99 | 63Amp DP MCB ISOLATOR |
| 100 | Internal PH worksSupplying all materials, labour, T&P and providing and fixing to wall or ceiling and floor C-PVC pipes conforming to pipe fittings of the following nominal bore with clamps including making good the wall, ceiling and floor all complete as per specification and direction of the Engineer in charge.(Pressure guage test for pipe )G Floor25mm dia C-PVC pipe (Ashirbad/Supreme/Oripalst) |
| 101 | 32mm dia P.V.C.ASTM(Sch.-80)Pipes |
| 102 | First Floor25mm dia C-PVC pipe (Ashirbad/Supreme/Oripalst) |
| 103 | 32mm dia P.V.C.ASTM(Sch.-80)Pipes |
| 104 | Supplying all materials, labour, T&P and fitting and fixing brass/CP fittings of the following nominal bore with supply of all jointing materials complete as per specification and direction of the Engineer in charge(below model or equivalent of any brand)16 mm dia CP Short body Bib cock()CON-CHR-049NKN |
| 105 | 15mm dia CP angle stop cock (FLR-CHR-5053N make) |
| 106 | 15mm dia CP Pillar cock (FLR-chr-5011N make) |
| 107 | 15mm dia CP two in one bib cock (FLR-CHR-5041N make) |
| 108 | 15mm dia CP Health faucet (ALD-CHR-573 make) |
| 109 | 25mm dia brass or gun metal fullway valve(Shakti Make) |
| 110 | 32mm dia brass or gun metal fullway valve(Shakti Make) |
| 111 | 15mm dia CP flange |
| 112 | 15mm dia CP extension piece |
| 113 | Supplying all materials,labour,T&P and fixing Rotational moulded polyethylene cylindrical vertical water storage tanks conforming to IS : 12701-1996 including cutting holes through the tank and fixing mild steel tubes and fittings and providing extra sockets and jam nuts, fixing ball valve etc, including hoisting upto a height of 5 metres above ground level and placing the tank to the required position and providing 1st class Fly ash brickwork in cement mortar (1:6) of 0.46m height in staging and in circular protection wall to support the tank, 12mm thick cement plaster (1:6) over brickwork, R.C.C slab of size 1.60mx1.60m and 0.10m thick, R.C.C beam of 0.25mx0.30m and 2.60m average length in cement concrete(1:2:4) using 12mm size h.g chips including centering and shuttering, watering, curing, conveyance of all materials to worksite etc all complete as per specification and direction of the Engineer in charge 2000 litre capacity water storage Sintex tank on the roof of 2nd floor. |
| 114 | Supplying all materials, labour, T and P and fitting and fixing U PVC SWR soil waste ventilating pipes and fittings of the following outside diameter conforming to ISI No. 13592 1992 to walls with nails, bobbins and wooden plugs or laying in trenches including jointing with supply of approved rubber lubricant by non heat application method as per manufacturers specification, testing, earthwork in excavation in all kinds of soil and refilling of trenches as per specification and direction of the engineer in charge 110mm dia U PVC SWR pipes Supreme Ashirvad |
| 115 | 100mm dia U-PVC 'P' trap |
| 116 | 110mm dia U-PVC Door Tee |
| 117 | 100mm dia U-PVC Plain Bend |
| 118 | 100mm dia U-PVC Door Bend |
| 119 | 100mm U-PVC Door Cross Tee |
| 120 | 110mm dia Vent cowl. |
| 121 | PVC Clamp suitable for 75mm to 110mm dia pipe |
| 122 | 125mm dia CP grating |
| 123 | Supplying all materials, labour, T&P and fitting and fixing 10 litres capacity low level flushing cistern with a pair of cast iron or M.S brackets complete with fittings such as siphonic arrangements 15mm nominal size brass/pvc ball valve with polythene float CP brass handle, unions and couplings for connection with inlet, outlet and overflow pipes,32mm dia CP flush bend,15mm dia pvc inlet connection pipe including cutting holes and making good the same and connecting the flush bend with cistern and closet and connecting the inlet pipe with supply main etc all complete as per specification and direction of the Engineer in charge. 10 litres capacity pvc low level cistern with 32mm dia CP long flush bend Slimline white (Parryware/Hinware) |
| 124 | Supplying all materials, labour, T and P and fixing the following vitreous china Wash Down Water Closet (European type W.C pan) with integral P or S trap to the floor with wooden plug and chromium plated pedestal screws including jointing the trap with soil pipe in cement mortar (1:1), fixing plastic seat and cover for wash down water closet with chromium plated brass hinges and rubber buffers including polishing etc all complete as per specification and direction of the Engineer in charge. European water closet with S trap plain E.W.C. with seat cover (Parryware/Hindware) |
| 125 | Supplying all materials, labour, T and P and fixing wash basins with hole for pillar taps with cast iron or M S brackets painted white including cutting holes in walls and making good the damages with supply of wooden plugs, screws and cement etc, fixing pedestal for wash basin recessed at the back for the reception of pipes and fittings, fixing PVC waste pipe of 32mm nominal diameter for wash basin including brass check nut complete, fixing pillar taps capstan head screw down high pressure lettered Hot and Cold with long screws, shanks and back nuts of 15mm dia nominal bore, fixing 15mm dia PVC inlet connection pipe and making connection with pillar cocks and supply mains for wash basin, fixing 32mm dia CP brass waste, etc all complete as per specification and direction of the Engineer in charge. 550mmx440 mm size wash hand basin With porcelain pedestal (Parryware/Hindware) |
| 126 | Supplying all materials, labour, T&P and fixing mirror of superior glass conforming to IS:3438-1996 mounted on 6mm thick A.C sheet or plywood sheet and fixed to wooden plugs with CP screws and washers complete as per specification an direction of the Engineer in chargeDesign mirror(Parryware) |
| 127 | Supplying all materials, labour, T&P and fixing standard sized glass-shelf with CP brass brackets and guard rails complete fixed to wooden plugs with CP screws as per specification and direction of the Engineer in chargeGlass shelf 600mm long(ACN-CHR-1171N or equivalent of any brand) |
| 128 | Supplying all materials, labour, T&P and fixing standard sized CP towel rail complete with CP brass brackets fixed to wooden plugs with CP screws as per specification and direction of the Engineer in charge25mm x 600mm long CP towel rail ACN-CHR-1111SM equivalent of any brand |
| 129 | Towel Ring Round - (As Per Cat no.:ACN-CHR-1121BN equivalent of any brand |
| 130 | Supplying all materials, labour, T&P and fixing CP soap holder complete with CP brass brackets fixed to wooden plugs with CP screws as per specification and direction of the Engineer in charge CP soap holder AKP-ABR-35731P or equivalent of any brand Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Jul 27, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedAug 10, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 7 daysAug 11, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 8 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender