Educational and Research Institute Government Departments Closing in 11 days TDR #56682116

Tender For Electrical Installations ,Wiring, Illumination , Repair And Maintenance Works In The Rooms/Labs No. 106,114,116, 127, 205,211,220,219 , 221, Lt-1 , Common Corridore ,Washroom And Faculty Chambers Of The Ceramic Engineerin Department, Iit(B

Issued by Government Departments · Varanasi, Uttar Pradesh
Tender Value
50.67 Lakhs
Estimated cost
Bid Submission
10 Aug 2026
11 days left
EMD
1.01 Lakhs
Bank guarantee accepted
Document Fee
Ref. Documents
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Varanasi → Uttar Pradesh
EMD Exemption
Not Available
Quantity
Not Available

Project Description

Tender for Electrical Installations ,Wiring, Illumination , Repair And Maintenance Works In The Rooms/Labs No. 106,114,116, 127, 205,211,220,219 , 221, Lt-1 , Common Corridore ,Washroom And Faculty Chambers Of The Ceramic Engineerin Department, Iit(Bhu), Varanasi.

BOQ

Name of Work:- Electrical installations ,Wiring, Illumination , Repaire and Maintenance works in the rooms/Labs no. 106,114,116, 127, 205,211,220,219 , 221, LT-1 , Common Corridore ,Washroom and faculty chambers of the Ceramic Engineerin Department, IIT(BHU), Varanasi.
Sl. No. Item Description
1Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed steel conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required. (Make: Polycab/ Finolex/ L&T/KEI )
2Group C
3Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single Core.(Make: Polycab/ Finolex/ L&T /KEI)
42 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire
52 X 4 sq. mm + 1 X 4 sq. mm earth wire
62 X6sq. mm + 1 X 6 sq. mm earth wire
74 X 6sq. mm + 2 X 6 sq. mm earth wire
84 X 10sq. mm + 2 X 6 sq. mm earth wire
9Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 A modular socket outlet and 5/6 A modular switch, connections etc. as required.Make: L& K(Entice)/ABB (tbisha white/IVIE /LEGRAND(mylinc) /INDOASEANHonywell/Schneider/legrand)
10Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 A modular socket outlet and 15/16 A modular switch, connections etc. as required.Make: L& K(Entice)/ABB (tbisha white/IVIE /LEGRAND(mylinc) /INDOASEAN/Honywell/Schneider/legrand)
11Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providng and fixing 2 nos. 3 pin 5/6 A modular socket outlet and 2 nos. 5/6 A modular switch, connections etc. as required. (For light plugs to be used in non residential buildings). Supplying and fixing PVC batten/
12Supplying & fixing suitable size GI/PVC box wih modular plate and cover in front on surface or in recess including providing and fixing 25 A modular socket outlet and 25 A modular SP MCB, “C” curve including connections, painting etc. as required. Make: L& K(Entice)/ABB (tbisha white/IVIE /LEGRAND(mylinc) /INDOASEAN)
13Providing and fixing following rating and breaking capacity TP&N Discannector release and terminal spreaders in existing cubicle panel board including drilling holes in cubicle panel, making connections, etc. as required. (Make- L & T/ABB/LEGRAND /INDOASEAN)
1463 A TP&N
15Providing and fixing following rating and breaking capacity and pole MCCB with thermomagnetic release and terminal spreaders in existing cubicle panel board including drilling holes in cubicle panel, making connections, etc. as required.(Make- L & T/ABB/LEGRAND /INDOASEAN)
16125 A,36KA,FPMCCB
17Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator)(Make- L & T/ABB/LEGRAND /INDOASEAN)
188 way , Double door
19Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MOB distribution board, 415 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator)(Make- L & T/ABB/LEGRAND /INDOASEAN)
208 way (4 + 24), Double door
21Supplying and fixing of following ways surface/ recess mounting, vertical type, 415 V, TPN MOB distribution board of sheet steel, dust protected, duly powder painted, inclusive of 200 A tinned copper bus bar, common neutral link, earth bar, din bar for mounting MCBs (but without MCBs and incomer ) as required . (Note : Vertical type MOB TPDB is normally used where 3 phase outlets are required.) (Make- L & T/ABB/LEGRAND /INDOASEAN)
228 way (4 + 24), Double door
23Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, \\"C\\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MOB DB complete with connections, testing and commissioning etc. as required.
24Single Pole MCB Make-L&T/ABB/C&S/Legrand/Hagger/Seimens/Schneider
25Double Pole MCB Make-L&T/ABB/C&S/Legrand/Hagger/Seimens/Schneider
26Triple Pole MCB Make-L&T/ABB/C&S/Legrand/Hagger/Seimens/Schneider
27Supplying and fixing DP sheet steel enclosure on surface/ recess along with 25/32 A 240 V \\"C\\" curve DP MCB complete with connections, testing and commissioning etc. as required.
28Supplying and fixing TP sheet steel enclosure on surface/ recess along with 16/25/32 A 415 V \\"C\\" curve TP MCB complete with connections, testing and commissioning etc. as required.
29LED Panel light 2x2 ft., (System lumen efficacy >135 lm/Watt) Supplying, installation, Testing & Commissioning of Panel light 2x2 ft., of following body material and construction as per IS : 10322 with driver as per the requirement with Driver efficiency >85%, Operating voltage AC 140-270 Volt, frequency 50/60 hz, Operating temp range -5 0C to 40 0C, internal surge protection of 2.5 KV with Short & Open circuit protection, THD < 10% , P. F.≥0.95, IP20, CRI >80,UGR (Unified Glare Rating) < 19, Flicker free, (flicker should be below 5 %), life time (LED, Driver & electrical circuitry), of minimum 50000 Burning Hours with , 70% of initial Lumen maintained till life ends ,CCT 3000°K / 4000°K / 5700°K /6500°K (As per ANSI Bin), SDCM(Standard Deviation Colour Matching) <3, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard. Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing. complete in all respect i/c external connections with 1.5 sq.mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy >135 lm/Watt output . LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in- Charge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C). Powder coated die cast /Extruded aluminium Body (Thickness > 1.20 mm)
3036 watt Make-Phillipse/Wipro/Polycab/CG
3118-20 watt 1x1 Make-Phillipse/Wipro/Polycab/CG
32LED Batten light (System lumen efficacy ≥120 <135 lm/Watt) Supplying, installation, Testing & Commissioning of LED surface mounted Batten light of following body material and construction as per IS : 10322 with driver (Replaceable) as per the requirement with Driver efficiency >85%, Operating voltage AC 140- 270 Volt, frequency 50/60 hz, Operating temp range -5 0C to 40 0C, internal surge protection of 2.5 KV with Short & Open circuit protection ,THD < 10% , P. F.≥0.95, IP20, CRI >80, Flicker free (flicker should be below 5 %), life time (LED,Driver & electrical circuitry), of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends, CCT 3000°K / 4000°K / 5700°K /6500°K(As per ANSI Bin), SDCM(Standard Deviation Colour Matching) <3, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard. Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing. complete in all respect i/c external connections with 1.5 sq.mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy ≥120 <135 lm/Watt output . LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C).
3336 watt Make-Phillipse/Wipro/Polycab/CG
34Earthing with G.I. earth pipe 4.5 metre long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal/ coke and salt as required.
35Supplying and laying 6 SWG G.I. wire at 0.50 metre below ground level for conductor earth electrode, including connection/ termination with GI thimble etc. as required.
36Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.
373.5 X 95 sq. mm (45mm)
38FP MCB 40/63 A Make-L&T/ABB/C&S/Legrand/Hagger/Seimens/Schneider
39Supplying and laying of PVC insulated, PVC sheathed XLPE aluminium conductor armored cable of Following size, 1.1 KV grade, direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc. as required. etc. as required [conforming to I.S-1554/1/8].
403½ X 185 sq. mm
413½ X 95 sq. mm
42Supplying and installation following size of DLP PVC Universal Adaptable Truncking for installation of Base cover partition Finsishing accessories and Mounting wire Accessories. with cable trays bends with perforation not more than joined with connectors, suspended from the ceiling with two numbers I Suspenders i/c base of suitable size wire angle, bolts & nuts, painting suspenders, fastener etc as required.
43105mm width X50 mm.
44Supplying and installation following size of perforated painted with powder coating M.S. cable trays bends with perforation not more than 17.5%, joined with connectors, suspended from the ceiling with two numbers MS/GI Suspenders i/c base of suitable size MS/GI angle, bolts & nuts, painting suspenders, fastener etc as required.
45150 mm width X 50 mm depth X 1.6 mm thickness
46LED Flood Light, powder coated pressure die cast aluminium (System lumen efficacy >135 lm/Watt) Supplying, Installation, Testing & Commissioning of Flood Light, powder coated pressure die cast aluminium body with built in or separate driver as per the requirement with Driver efficiency >85%, Input voltage: Input voltage: 140-270 Volt AC, frequency 50/60 hz, Operating temp range -5 0C to 50 0C, internal surge protection of 5 KV L,N,E as per IEC 61000-4-5, Driver efficiency >85%,THD < 10% as per IEC 61000-3-2, P. F.≥0.95, IP-66,IK-10, CRI >70, under voltage and over voltage protection, EMI-EMC as per CISPR-15, lenses for beam angle 30 deg-120deg as per the application and the project requirement., suitable tilt able fitting, life time (LED, Driver & electrical circuitry) of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends as per LM80 extrapolation IES TM-21-11 report, CCT 3000°K / 4000°K / 5700°K /6500°K (As per ANSI Bin), SDCM(Standard Deviation Colour Matching) <5, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard complete in all respect i/c external connections with 1.5 sq.mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy >135 lm/Watt output. LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C).
47100 WattMake-Phillipse/Wipro/Polycab/CG
48Supplying,Cutting of huck , painting and fixing of MS Down down conduit for installation of ceiling fan upto 3 to 5 feet
49Supplying and fixing of 230VAC 1Ph. 300 mm exhaust Fan with sweep feature. ( Make: Usha / ORIENT / CG)
50Supplying and fixing of 230VAC 1Ph.400 mm ,900 rpm Wall Fan Make-ORIENT/CG/USHA/Bajaj
51Supplying and fixing of 230VAC 1Ph.1400 mm ,2800 rpm celing Fan Make-ORIENT/CG/USHA/Bajaj
52Dismantling of Old wiring,Ceiling Fan ,Conduit and all electrical installations and make good as per the site requirment
53Supply, Installation ,testing & Commisionioning (SITC) of Indoor CPRI certified cubical Panel with EC grade Al busbar capacity 400Amp. 100% netural suitable >25ka for 3 sec for fault level ,compatiable for following incomming & outgoing . Custum built self fabricated out of 16SWG , CRCA sheet Foot mounted type Panel Furnished with siemen gray shade powder coated paint after necessary pre treatment fully dust & vermin proof, Copper wire ,Lugs and Netural & Insulating Material Engineering and Labor Charges , Panle size (H-W-D)mm. Details as Incoming-SFU 400 Amp. 2-nos. &6nos-HRC fuse, Incomer All Busbar capacity 400Amp. Phase indicating light shall be protected by 2 amps MCB‟s. - 3 Sets Outgoing Deatils , TP MCCB-2 Nos 160 Amp. & TP MCCB-4 Nos 125 Amp and 63 Amp. MCCB 4 nos. , Phase indicating light shall be proected by 2 amps MCB's - 3 Set , Breaker ON / OFF / TRIP indicating lights with control MCB's - 1 set Switch gear Make- Legrand,/L&K/ Simense/Schneider.Panel Make-Allied Engineer/Electrocare/Electrocraft /SK Electrical
54Earthing with copper earth plate 600 mm X 600 mm X 3 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 Meter long etc. with charcoal/ coke and salt as required. Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 56682116
AUTHORITY Government Departments
TENDER VALUE 50.67 Lakhs
LAST DATE 10-08-2026
Authority
Authority Name Indian Institute Of Technology
Work Description Tender for Electrical Installations ,Wiring, Illumination , Repair And Maintenance Works In The Rooms/Labs No. 106,114,116, 127, 205,211,220,219 , 221, Lt-1 , Common Corridore ,Washroom And Faculty Chambers Of The Ceramic Engineerin Department, Iit(Bhu), Varanasi.
Basic Detail
Tender No IIT(BHU)/IWD/ET-31/2026-27/376
Bidding Type Tender
Location
City Varanasi
State Uttar Pradesh
Key Dates
Publish Date 27 Jul 2026
Submission Date 10 Aug 2026
Open Date 11 Aug 2026
Finance
Tender Value 50.67 Lakhs
Tender Fee Ref. Documents
EMD 1.01 Lakhs
Exemption Not Available
Document List
BOQ_964142.xls
f2fa2cc0-c92e-4cba-8b0c-eac4ebfb6208.html
Tendernotice_1.pdf
Tender_Document_for_ET_31.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Jul 27, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Aug 10, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 11 days
Aug 11, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 12 days

Tender Documents

Download All (ZIP) ↓
xls

BOQ_964142.xls

html

f2fa2cc0-c92e-4cba-8b0c-eac4ebfb6208.html

pdf

Tendernotice_1.pdf

pdf

Tender_Document_for_ET_31.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail
Loading tenders