Tender For Construction Of Mini Community Sanitary Complex Type - V At Pums In Lalpuram Panchayat
Tender Value
5.96 Lakhs
Estimated cost
Bid Submission
14 Aug 2026
17 days left
EMD
5960
Bank guarantee accepted
Document Fee
Ref. Documents
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Cuddalore → Tamil Nadu
EMD Exemption
Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender for Construction Of Mini Community Sanitary Complex Type - V At Pums In Lalpuram Panchayat
BOQ
| Sl. No. | Item Description |
| 1 | Construction of Mini CSC Type - V at PUMS in Lalpuram Panchayat |
| 2 | Providing Pile Foundation 200mm dia 2.40m depth using reinforcement cement concrete 1:1.5:3 mix using 20mm ISS HBG Metal including cost and conveyance of all materials charges etc complete |
| 3 | Earthwork excavation in all classes of soils and depositing on bank with an initial lead and lift such as sand or other loose soil, wet sand not under water silt and ordinary soil, sandy loom, and hard stiff, black cotton soil, red earth, earth mixed with |
| 4 | Filling with good river sand into foundation and basement including cost and conveyance of all materials to work site and all labourcharges for filling, watering etc., complete. |
| 5 | CC 1:4:8 mix using 40mm ISSHBG metal including cost and conveyance of all materials to work site and all labour charges for mixing, laying and watering etc., complete. |
| 6 | Supplying and erecting centering for sides and soffits including necessary supports and strutting upto 3.29 M height for plane surfaces as detailed below in all floors with all cross bracings using Mild Steel sheets of size 90 x 60 cm and 10 BG stiffened with welded Mild Steel angle of size 25mm x 25mm x 3 mm for boarding laid over silver oak joists of size 10cm x 6.50 cm spaced at abote 90 cm centre to centre and supported by casurina props of 10cm to 13 cm dia spaced at not more than 75 cm centre to centre etc. complete complying with the standard specificaiton. (Payment for centering shall be given after the concrete is laid) Below Ground Level |
| 7 | Above Ground Level |
| 8 | Supplying, fabricating and placing in position Mild Steel / Ribbed Tor Steel grills for all RCC works as per design given including cost of steel and G.I. binding wire in all floors etc. complete complying with standard specification. (Contractor has to make his own arrangements for the supply of steel and binding wire) |
| 9 | Reinforced Cement concrete 1:1.5:3 mix using 20mm ISSHBG metal from approved sources including cost and conveyance of all materials to work site and all labour charges for mixing, laying, and watering etc., complete. Above basement |
| 10 | Above Ground Level |
| 11 | Brickwork in CM 1:5 mix using country bricks of standard size including cost and conveyance of all materials to work site and including all labour charges and all incidential charges etc., complete. Upto basement |
| 12 | Above Ground Level |
| 13 | Supplying and applying of two coats of putty of 3mm thick over the exposed RCC surface of ceiling including finishing the joints smoothy with grinding machine and the surface shall be thoroughly cleaned out of dust and scrubbing. The Surface shall then be allowed to dry for atleast 48 hours. It shall then be sand papered (waterproof abrasive sheet) to give a smooth and even surface. Any unevenness shall be made good by applying 1st coat of putty mixed with water on the entire surface including filling up the undulations and applying 2nd coat of putty after 6 hours of 1st coat of putty and then sand papering (waterproof abrasive sheet) the same after it is dry and finishing the surface smoothly, etc., complete complying with standard specifications and as directed by the Departmental Officers. [The rates are inclusive of hire charges for grinding machine with wheel, cost of sand paper (waterproof abrasive sheet), cost of putty blade, labour charges for grinding the joints and sand papering, two coat of putty, scrapping the putty area to level the surface smooth, etc., complete]. The Putty should be got approved by the Executive Engineer before use on work. |
| 14 | Special ceiling plastering and finishing the exposed surface of all RCC items of work such as slabs, beams, sunshades, facia, canopy slab, staircase waist slab, landing slab etc., with Cement Mortar 1:3 (One Cement and Three P.Sand) 10mm thick including hacking the surfaces, providing cement mortar nosing, beading for sunshades, staircases, steps, landing slabs and curing, etc., in all floors complying with standard specification and as directed by the departmental officers |
| 15 | Plastering in CM 1:5 ,12mm thick including cost and conveyance of all materials to work site and all labour charges etc., complete. |
| 16 | Flooring with following ceramic tiles of size 305 x 305 x 6 mm laid over 20 mm thick cement mortar 1:3 (One Cement and Three M.Sand) base mortar over the existing slab / floor including cutting the tiles to the required size with special cutter wherever necessary, laying in position and pointing with white cement mixed with colouring pigment at the rate of 0.3 Kg. / sq.m. etc., complete complying with standard specification. (The make and brand of the tiles should be got approved by Executive Engineer before use on works) |
| 17 | Dadooing walls with following best approved quality, white / colour glazed tiles of following sizes set in Cement Mortar 1:2 (One Cement and Two crushed stone M.Sand) 10mm thick and pointing the joints with white cement mixed with colouring pigments at the rate of 0.40 Kg. / sq.m. neatly in all floors, curing, etc., complying with standard specification and as directed by the departmental officers. |
| 18 | Flooring with Granolithic flooring to 25mm thick using CC 1:2:4 mix using 20mm ISSHBG metal including cost and conveyance of all materials to work site and all labour charges etc., complete. |
| 19 | 50mm Thick |
| 20 | Providing and Applying CFTRI approved two component flexible polymer modified acrylic cementitious waterproofing coating with a mix ratio of (5 Liquid :7 Powder) to the RCC surface like Roof, bathroom, toilet, balcony & utility area applied @ 2.2kg/m2 in 2 coats to achieve 1.2mm DFT, having Elongation at break >120% as per ASTM D 412, Tensile strength >1N/ mm2 as per ASTM D 412, Adhesion strength: 0.80N/mm2 as per ASTM D 4541, crack bridging upto 2mm as per ASTM C 836. The finished cost to include surface preparation, making coving of 50 mm X 50mm at all right angles of wall Junction with Polymer Repair Mortar and lay 45 gsm glass fibre mesh over the angle fillet when the first coat in still wet, treatment of cracks completely as per specification |
| 21 | Plastering with Cement Mortar 1:3 (One Cement and Three Plastering M.Sand) 20mm thick mixed with water proofing compound conforming to BIS at 2% by weight of cement used including finsihing, curing, etc., complete in all floors complying with standard specification and as directed by the departmental officers. |
| 22 | Painting the newly plastered wall surface with two coats of Plastic Emulsion Paint outside the building over one coat of cement primer including clearing the surface in all floors etc., complete as per standard specification. |
| 23 | Painting two coats over new iron works using ready mixed enamel paint including cost and conveyance of paint and all labour charges etc complete |
| 24 | Cost And supply For Indian Water Closet and including all labour charges etc complete |
| 25 | Cost And supply of Wash Basin and including all labour charges etc complete |
| 26 | Cost And supply For Steel door and including all labour charges etc complete main door 1.10x2.10 |
| 27 | 0.90x2.10 |
| 28 | Cost And supply For RCC Jolly and including all labour charges etc complete |
| 29 | Cost and Supply, fixing of Inspection chamber and including all labour charges etc complete |
| 30 | Provision for Soak Pit:Earth work excavation and depositing on bank with in initial lead of 10 m and initial lift of 2m in hard stiff clay, stiff black cotton soil, hard red earth,earth mixed with small sized boulders and hard gravelly soil as per SS 20B |
| 31 | Supplying and fixing P.V.C rainwater down fall pipe of 100mm dia |
| 32 | Towards Cost , Conveyance and fixing charges for RCC Rings 900mm dia including all cost etc., |
| 33 | Towards Cost , Conveyance and fixing charges for RCC Rings 1500mm dia including all cost etc., |
| 34 | Towards Cost , Conveyance and fixing charges for RCC Cover slab 900mm dia including all cost etc., |
| 35 | Towards Cost , Conveyance and fixing charges for RCC Cover slab 1500mm dia including all cost etc., |
| 36 | Cost and Supply Of Inspection Chamber and including all charges etc complete |
| 37 | Labour Charges for Erection of RCC Rings and Top Cover Slab |
| 38 | Provision for Water Supply Arrangements : PVC Tank |
| 39 | 25mm PVC Pipe |
| 40 | 25mm PVC Tee |
| 41 | 25mm PVC Elbow |
| 42 | 25mm FTA |
| 43 | 25mm PVC Ball Valve |
| 44 | Provision for Electrical Arrangements : Light Point |
| 45 | CFL Light |
| 46 | 0.50 HP Motor |
| 47 | Cost and Supply of Galvanised iron Sheet and including all labour charges etc complete |
| 48 | Cost and Supply of Square tube and including all labour charges etc complete |
| 49 | Provision for Bala Painting |
| 50 | Provision for Photo charges |
| 51 | Provision for Name board charges |
| 52 | GST Amount for providing Service to Government Contract Works for the above Construction & Maintenance Works. { GST Amount is the Total GST Amount for overall quoted amount (Both Construction and Maintenance) above this row in column \\"BB\\" for all works in this package} Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Jul 27, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedAug 14, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 17 daysAug 14, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 17 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender