Tender For Providing Of Certain Minor Works At Af Stn Palam Under Ge (Af) Palam, Delhi Cantt - 10
Tender Value
33.44 Lakhs
Estimated cost
Bid Submission
15 Aug 2026
0 days left
EMD
66900
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
New Delhi → Delhi
EMD Exemption
Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender For Providing Of Certain Minor Works At Af Stn Palam Under Ge (Af) Palam, Delhi Cantt - 10
BOQ
| Sl. No. | Item Description |
| 1 | M&L for (25x3.15) mm aluminium strips with and including on porcelain holder insulator for support on wall / roof/Hangar roof and walls any height etc with suitable size screw, nut, bolts etc complete all as specified and asdirected. |
| 2 | M&L for (25x3.15) mm aluminium strips connected to air termination rod duly aluminium welded for securing air termination and continuous roof conductor network complete all as specified and asdirected. |
| 3 | M&L for (32x6)mm galvanised iron strip including fixing on porcelain holder insulator for support on wall / roof etc with suitable size screw, nut, bolts etc complete all as specified and as directed. |
| 4 | Material and Labour for test point terminal block made of gun metal or phosphorus bronze size (75mm x75mm x 25mm) drilled and screwed including 3 nos. 8 mm dia 25mm long hexagonal head screw complete all as specified and as directed by Engr-in-Charge. |
| 5 | M&L for GI pipe medium grade 32mm dia 2 metre long with anchor plate 3mm thick 50mm x 50mm welded at the bottom grouted on the bed block including 3mm thick MS cap complete with 12mm bore drilled on the MS cap and fixing one GI nut duly welded on the inner surface of the cap suitable for fixing of the air termination rod complete all as specified and as directed. |
| 6 | M&L for air termination, single pointed, copper rod 12mm dia and 300mm long including threading on blunt end complete all as specified and as directed. |
| 7 | M&L for precast PCC (1:3:6) type C1 (using 20mm graded stone aggregate) as in bed block of size (300 x 300 x 450)mm for fixing GI pipe 32mm dia medium grade with air termination rod vertically on roof complete all as specified and as directed. |
| 8 | M&L for earthing with galvanized mild steel earth plate electrode (60cm x 60cm x 6mm thick) buried directly in ground (earth pit not less than 2.25 Mtr below ground level) with top edge of earth plate not less than 1.5 Mtrs below ground level connected to GI strip (32 x 6)mm as earth lead by means of nuts, bolts, thimbles, chuck nuts, washers of GI or steel, including PCC (concrete chamber) of PCC (1:3:6) type C-1 (using 20mm graded stone aggregate), with fair finish internal surface of concrete chamber shall be 15mm thick plaster in CM (1:4), funnel with wire gauge mesh, 80mm thick RCC pit cover (320mm x 320mm) of RCC (1:2:4) type B-1 (using 20 mm graded stone aggregate) reinforced with XPM, JALLI and charcoal dust and common salt all as shown in electrical plate No 3 of MES SSR Part-I (2009) and specified including provision of GI strip protected by 40mm dia light grade GI pipe and watering pipe shall be 20mm bore medium grade and including all excavation and earth work & connecting the earthing to an earthing test point complete all as specified and as directed by Engr-in-Charge. |
| 9 | Supply and installing hi wall split type air conditioner \\"Hot & Cold\\" with indoor & outdoor unit complete with inverter technology, 3D Airflow, power chill operation, cordless remote control unit and with in- built air ioniser, PM 2.5 filter for better indoor air quality with maximum star rating as per OEM of capacity 2 TR with precharged CFC free (R32/R410A) refrigerant all as specified including minimum 3 Mtr copper pipe each suction & discharge, copper power cable upto 3.5 mtrs complete all as specified and as directed by Engr-in-Charge. Note:- Outdoor stand with anchor fastener shall be deemed to be included in the item rates. Make:- Voltas/ Llyod / LG / Blue Star / Samsung / Godrej / Haier. |
| 10 | Supply and installing voltage stabilizer for automatic operation single phase naturally air cooled indoor type & designed for input variation between 170 V to 250 V with output voltage stabilized at 230 V accuracy of 2.5 % and capacity of size 5 KVA complete all as specified and as directed by Engr-in-Charge. |
| 11 | Supply and fixing DBOXx MCB protected socket PVC plastic modular AC box with single pole MCB 20 Amps 'C' series and heavy duty ISI marked 3 Pin Plug top 20 Amps complete all as specified and as directed. |
| 12 | M&L for sub main wiring with two single core PVC insulated stranded unsheathed FR PVC insulated cable copper conductor single core with size 6 Sqmm (2 x 6sqmm + 1 x 6sqmm) and drawing through non metallic PVC rigid conduit conealed/surface on wall including PVC insulated unsheathed stranded copper conductor cable connected to earth and earth dolly in conduit including connecting to main board complete all as specified and as directed. |
| 13 | S&F drain pipes 25 mm dia heavy duty rigid PVC from indoor unit to existing point as per design including accessories i.e. clamps, fastener etc complete all as specified and as directed by Engineer in Charge. |
| 14 | S&F additional copper tubing 1/4\\" with rubber insulation unit suitable for 1.5 TR Split AC complete all as specified and as directed by Engineer in Charge. |
| 15 | S&F additional copper tubing 1/2\\" with rubber insulation unit suitable for 1.5 TR Split AC complete all as specified and as directed by Engineer in Charge. |
| 16 | S&F additional copper cable 4 core 2.5 sqmm suitable for 2 TR Split AC complete all as specified and as directed by Engineer in Charge. |
| 17 | S&F MCB SP 5 to 32 Amps, 240 volts curve 'C', breaking capacity 10 kA complete all as specified and as directed by Engineer in Charge. |
| 18 | Excavation in trenches in soft/loose soil exceeding n exc 1.50 Mtrs wide and exc. 1.5 Mtr but n exc 3.0 mtr deep and getting out for taking out/laying cable, poles & stay etc complete all as specified and as directed. |
| 19 | Returning, filling in including spreading, leveling, watering and well ramming in layers not exc 25 cm thick after the cable have been laid, tested complete all as specified and as directed. |
| 20 | Removal of excavated surplus soil to a distance not exc. 50 Mtrs and depositing where directed at a level not exc 1.5 Mtr above the starting point complete all as specified and as directed. |
| 21 | M&L for sand cushioning to under ground cable provided with layer of sand (8cm deep before laying the cable and 15 cm deep after laying the cable ie total 23 cm) complete all as specified and as directed. Note:- Punned thickness shall only be measured and paid. |
| 22 | M&L for brick laid in trenches for cable protection of burnt clay sub class ‘B’ complete laid dry flat complete all as specified and as directed. |
| 23 | M&L for galvanised steel tube, light grade with all fittings complete laid in trenches/ road / Path/ on pole of 40mm bore complete all as specified and as directed. |
| 24 | S&F LED beacon light fittings 10 watt cool white/warm white 1000mm height 230 volt AC outdoor type with decorative for 360 degree indirect light IP 65 protection with impact and corrosion resistant with driver and lamp complete with opal diffuser and aluminium reflector with all accessorries internally prewired and including base & PCC work connecting with twin core copper conductor cable complete all as specified and as directed. Make:- Halonix HLOB-05-10-CW-01M or Eveready LEDBLB01015-01 or equivalent as per list of makes. |
| 25 | Supply, laying and testing in ducts, along wall or passing through pipe XLPE insulated, LT 1100 Volt grade, heavy duty, screened, PVC bedded galvanised steel strip armoured electric cable of size 16 Sqmm 4 core aluminium conductor complele all as specified and as directed. Notes:- Excavation, earth work and protection of cable shall be measured and paid seperately. |
| 26 | S&F LED flood light fitting 70 Watt, system efficiency not less than 100-120 lumen / watt, IP66 including 10KV SPD, consisting of high / low voltage cut off, maintenance free isolated electronic driver circuits, low THD, PMMA grade high quality transmittance lens, epoxy powder coated die cast aluminium housing with weather proof gasket for lamp & driver compartment, heat resistance toughened glass fitted in cast aluminium housing with SS screws, fixed on existing high mast & connecting complete all as specified and as directed. |
| 27 | S&F street light timer switch panel board suitable for 3 phase, 4 wire, 415 volt, fabricated in approved factory with 2mm CRCA sheet metal IP54 for outdoor pole / wall mounting powder coating in approved shade with weather proof canopy and lock 32 Amps operating voltage 415 volts three phase, astronomical / digital timer switch capable of multiple daily operation with real time back up, power contactor 4 pole 32 Amp relay, MCB TP complete all as specified and as directed. |
| 28 | S&F LED post top lantern 20W, 230 volt AC outdoor type with decorative post top for 360 degree indirect light IP 65 protection with impact and corrosion resistant complete with driver and lamp complete with all accessorries internally prewired and including base and PCC work connecting up with twin core copper conductor cable complete all as specified and as directed. |
| 29 | M&L for earthing with galvanized mild steel earth plate electrode (60cm x 60cm) x 6mm thick buried directly in ground (earth pit not less than 2.25 Mtr below normal ground level) with top edge of earth plate not less than 1.5 Mtrs below ground level, connected to GI 4mm dia wire as earth lead by means of nuts, bolts, thimbles, chuck nuts, washers of GI or steel, including PCC (concrete chamber) shall be PCC (1:3:6) type C-1 (using 20mm graded stone aggregate), with fair finish internal surface of concrete chamber shall be given 15mm thick plaster in CM (1:4), funnel with wire gauge mesh, 80 mm thick RCC pit cover 320mm x 320mm of RCC (1:2:4) type B-1 (using 20mm graded stone aggregate) reinforced with XPM, JALLI and charcoal dust and common salt all as shown in electrical plate No 3 of MES SSR Part-I (2009) and specified including provision of GI strip protected by 15mm dia medium grade pipe and watering pipe shall be 20mm bore medium grade, and including all excavation and earth work & connecting the earthing to an earthing test point complete all as specified & as directed by Engr-in-Charge. |
| 30 | S&F decorative pole tear top 4 mtr double arm pole for pendent light 45 watt 230 volts AC outdoor type with decorative for 360 degree indirect light IP65 protection with impact and corrosion resistant with driver and lamp complete with opal diffuser and aluminium reflector with all accessories internally prewired and including base & PCC work connecting up with twin core copper conductor cable complete all as specified and as directed. Make:- Eveready DPGI04DA-PL or equivalent in Halonix, Havells or as approved by the GE. |
| 31 | M&L for augering of holes in true horizontal position under road /pavement by means of mechanical rig after doing ultrasound technique to prevent any damage to existing cables/pipe lines coming in route 1.5 Mtr deep and not exceeding 8 Mtrs long including laying HDPE pipe of 100mm dia complete all as specified and as directed. |
| 32 | Supply and installation air cooled hi wall split type airconditioner inverter type 5 star BEE rating for 1.5 TR complete with indoor unit (IDU), Outdoor unit (ODU), surface/concealed copper refrigerant piping with insulation (closed cell elastomeric nitrile rubber tubular pipe section) minimum 3 mtr (IDU to ODU), copper power cable upto 3.5 Mtr (IDU to ODU) I/C drain pipe R-32/R-407 green refrigerant, wireless remote control, suitable for working between 180-260V with low and high voltage cutoff and 50Hz, 1 Phase AC supply capable of performing cooling, dehumidification, air circulation of following capacity with rotary compressor. The system shall be able to deliver 100% of the rated capacity upto 42 degree calcius. Minimum 5 years original equipmenr manufacturer (OEM) warranty both compressor and printed circuit board (PCB). Must comply with Electrical IS 694 or IS 9968 temperature sensing control IS/ International Electrotechnical Commission (IEC) 60730, hermetic compressor IS 10617, heat exchanger IS 11329, capacitor IS 2993 and motor IS 12615. Note:- Outdoor stand with anchor fastner shall be deemed to be included in the item rates. Make:- Voltas/ Llyod / LG / Blue Star / Samsung / Godrej / Haier. |
| 33 | S&F suction and discharge copper tubing from indoor to outdoor unit of split type Acs of capacity 1.5/2.0 TR capacity with neoprene foam sleeves including sealing by applying adhesive tape of brown or white colour to avoid minimum contact with atmosphere complete all as specified and as directed. |
| 34 | S&F additional copper tubing 5/8\\" with rubber insulation unit suitable for 1.5 TR Split AC complete all as specified and as directed by Engineer in Charge. |
| 35 | S&F additional copper tubing 3/8\\" with rubber insulation unit suitable for 1.5 TR Split AC complete all as specified and as directed by Engineer in Charge. |
| 36 | M&L for sub main wiring with two single core PVC insulated stranded unsheathed FR PVC insulated cable copper conductor single core with size 4 Sqmm (2 x 4sqmm + 1 x 4sqmm) and drawing through non metallic PVC rigid conduit conealed/surface on wall including PVC insulated unsheathed stranded copper conductor cable connected to earth and earth dolly in conduit including connecting to main board complete all as specified and as directed. |
| 37 | S&F distribution board SPN 415 volt, 8 way double door complete all as specified and as directed. |
| 38 | S&F MCB SP 240 volt, 5-32 Amp 'C' series complete all as specified and as directed. |
| 39 | S&F MCB SPN 240 volt, 40-63 Amp 10 kA 'C' series complete all as specified and as directed. |
| 40 | S&F 25mm bore GI tubing medium grade laid in trenches/on wall complete all as specified and directed by Engineer-in-Charge. Note:- Excavation and earthwork for laying of pipe shall be measured and paid seperately. |
| 41 | S&F 40mm bore GI tubing medium grade laid in trenches/on wall complete all as specified and directed by Engineer-in-Charge. Note:- Excavation and earthwork for laying of pipe shall be measured and paid seperately. |
| 42 | S&F 25mm bore gate valve gun metal globe with iron wheel head screwed both ends for iron pipe conforming to IS complete all as specified and directed by Engineer-in-Charge. |
| 43 | S&F 40mm bore gate valve gun metal globe with iron wheel head screwed both ends for iron pipe conforming to IS complete all as specified and directed by Engineer-in-Charge. |
| 44 | M&L for construction of valve pit of size (900mm x 900mm x 900mm) with bottom 15cm thick PCC (1:4:8) type D-2 (using 40mm graded stone aggragates) and brick work with sub class \\"B\\" brick in cement mortar (1:4), plaster inside and outside using CM (1:4) with and including MS sheet cover fabricated not less than 2mm thick sheet steel and frame of angle iron (50mm x 50mm x 5mm) including locking arrangement and painting two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified and directed. |
| 45 | M&L for cutting the existing main water supply pipe line 100mm bore GI/CI/DI line and insert Tee suitable for insertion of 40mm pipe (Tee 100mm x 40mm) including tee and all jointing material and excavation and returning filling complete all as specified and as directed. |
| 46 | M&L for point wiring with single core PVC insulated unsheathed 1.5 sqmm FRLSH multistranded copper conductor cable 1100 volts grade IS-694 marked drawn in and including rigid non metallic PVC conduit medium grade not less than 20mm dia ISI marked with all conduit fittings and fixing accessories suitable for mounting modular switches including modular metal flush box and modular face plate with frame for mounting switches, sockets, fan regulators, etc and earth wire single core PVC insulated but unsheathed multistranded copper conductor cable 1100 volts grade IS-694 marked 1.5 sqmm FRLS cable as continuous earth wire connecting to common earth dolly in concealed wiring system includes cutting of chases and making good disturbed surfaces complete all as specified and as directed for the following:- (a) One light/fan point controlled by one switch one way |
| 47 | (b) One 3 pin 5 Amps socket out let point on the same board controlled by one switch complete all as specified and as directed. |
| 48 | (c) One socket outlet 5 Amp controlled by one switch on independent board complete all as specified and as directed. |
| 49 | All as per Srl item No 46.00 here-in-before but for one power point 6 pin 15 Amps socket out let with 2.5 sqmm stranded copper conductor cable PVC insulated including earth wire 2.5 sqmm copper conductor cable connected to earth dolly complete all as specified and as directed. |
| 50 | M&L modular switch 1 way 6 Amps 1 module complete all as specified and as directed. |
| 51 | M&L modular switch 1 way 16 Amps 1 module complete all as specified and as directed. |
| 52 | M&L modular socket outlet 6A, 2/3 pin combined 2 module complete all as specified and as directed. |
| 53 | M&L modular socket outlet 6A/16A, 2/3 pin combined 2 module complete all as specified and as directed. |
| 54 | Supply and fixing ceiling rose, surface type, 65mm x 50mm, 2 to 3 terminal complete all as specified and as directed. |
| 55 | Supply and fixing enviroment friendly indoor decorative 20 watt LED for wall mounted 20 Watt LED batten, extruded aluminium heat sink provided for heat dissipation and integrated electronic driver back plate suitable for batten fittings complete all as specified and as directed. Make:- Havells Cat LHEWEBP7IN1W020 or equivalant as per list of makes. |
| 56 | M&L sheet metal enclosure for DBs 8 way double door type with 200 amps rated busbar SPN including necessary connection complete all as specified and as directed. |
| 57 | Supply and fixing vertical type load line distribution board, double door, 6 way, AC, 3 Phase, 415 volts ,TPN, bus bar 200 Amps rating and earth bus & din rail suitable for MCCB as incomer complete all as specified and as directed. |
| 58 | Supply and fixing MCCB 125 Amps 4 pole 16 kA 415 Volts 50 Hz with thermal adjustable magnetic settings, necessary conection including taking out old existing unserviceable MCCB from panels/VTPN etc complete all as specified and as directed. |
| 59 | Supply and fixing single pole and neutral enclosure with a two pin and earth plug and socket complete with one single pole MCB SP 20-32 Amps 'C' series complete all as specified and as directed. |
| 60 | M&L for rigid non-metallic PVC conduit exclusive of boxes (junction/terminal) but inclusive of all tees, bends, elbows, reducers, bellmouth tube ends and fixing accessories such as couplers, lock, nuts, saddles, pipe hooks etc. complete all as specified and as directed. |
| 61 | M&L for cutting chases, pinning in, making good to facings where required and pointing in cement mortar (1:3) to ends or edges of landings, steps, cills, sunshades, shelves, lintels, etc and cutting chases for concealed water tubing or concealed conduit wiring etc. and making good, cutting exceeding 20 cm girth complete all as specified and as directed. |
| 62 | Supply, installation, testing and commissioning of 1200mm sweep, BEE 5 star rated, ceiling fan with brush less direct currecnt (BLDC) Motor, class of insulation : B 03 Nos blades, 30cm long down rod, 2 nos canopies, shackle kit, copper winding, power factor not less than 0.9, Service value (CMM/W) minimum 6.00, Air delivery minimum 210CMM, 350RPM (tolerance as per IS : 374-2019), THD less than 10%, with remote unit for speed control and all remaining accessories including safety pin, nut, bolts, washers, temperature rise+75 degree C (max), insulation resistance more than 2 mega ohm, suitable for 230v 50Hz, single phase AC supply, earthing connection etc. complete all as specified and as directed. Make:- Bajaj Energos12DC5R, Havells 1200DC30w350, Crompton Energion Regmote or equivalent as per list of makes. Note:- Contractor shall provide warranty from OEM of fan for 03 years in replacement if defective during period. |
| 63 | M&L for stickers/radium strips for ceiling/exhaust fan & geysers on front face printed with SM/MES Numbers including preparation of surface complete all as specified and as directed. Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Jul 25, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedAug 15, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
CompletedAug 22, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 6 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender