Tender For Provn Of Otm Accn With Allied Infra For Trainees At Mcmm Jabalpur
Tender Overview
Project Description
Tender for Provn Of Otm Accn With Allied Infra For Trainees At Mcmm Jabalpur
Corrigendum
| Sr No | Corrigendum Date | Corrigendum | Type | New Submission Date |
|---|---|---|---|---|
| 1 | 21-Aug-2026 | C1 | Date | 14-Sep-2026 |
BOQ
| Sl. No. | Item Description |
| 1 | SCHEDULE \\"A\\" Part-I (Building/Structures) (To be quoted by the tenderer) |
| 2 | Item No 01A : Construction of block of Living Accn for 202 men (NCOs/ORs) Plinth area 6731.10 sqm) (G+4) Group II (iii), with permanent specification including RCC frame structure, OBD in lieu of dry distemper, pre- construction ATT, APP water proofing treatment, external emulsion paint, mosquito proofing complete all as specified in soil bearing capacity report, design basis report, drawings and tender documents. |
| 3 | Item No 01B : Construction of block of Parking Shed for 202 men (Car andScooter) Plinth area 1815.0 sqm) (SS) Group VII (viii), with permanent specification including RCC frame structure, APP water proofing treatment, external emulsion paint, mosquito proofing complete all as specified in soil bearing capacity report, design basis report, drawings and tender documents. |
| 4 | Item No 01C : Construction of block of Cook House and Dining Hall for 202 Men Plinth area 622.62 sqm) (SS) Group III (i), with permanent specification including RCC frame structure, OBD in lieu of dry distemper, pre- construction ATT, APP water proofing treatment, external emulsion paint, mosquito proofing complete all as specified in soil bearing capacity report, design basis report, drawings and tender documents. |
| 5 | Item No 01D : Construction of block of Kitchen Plinth area 79.75 sqm) (SS) Group III (i), with permanent specification including RCC frame structure, OBD in lieu of dry distemper, pre- construction ATT, APP water proofing treatment, external emulsion paint, mosquito proofing complete all as specified in soil bearing capacity report, design basis report, drawings and tender documents. |
| 6 | Item No 01E : Construction of block of Single JCOs Accn for 63 JCOs Plinth area 3823 sqm) (G+7) Group IV, with permanent specification including RCC frame structure, OBD in lieu of dry distemper, pre- construction ATT, APP water proofing treatment, external emulsion paint, mosquito proofing complete all as specified in soil bearing capacity report, design basis report, drawings and tender documents. |
| 7 | Item No 01F : Construction of block of Parking Shed for Car, scooter for 63 JCOs, Plinth area 578 sqm) (1) Group VII (viii), with permanent specification including RCC frame structure, OBD in lieu of dry distemper, APP water proofing treatment, external emulsion paint, mosquito proofing complete all as specified in soil bearing capacity report, design basis report, drawings and tender documents. |
| 8 | Item No 01G : Construction of block of Cook House and Dinning Hall for 63 JCOs, Plinth area 429.63 sqm) (1) Group III (i), with permanent specification including RCC frame structure, OBD in lieu of dry distemper, APP water proofing treatment, external emulsion paint, mosquito proofing complete all as specified in soil bearing capacity report, design basis report, drawings and tender documents. |
| 9 | Sch 'A' Part-II (External Electric supply) Lump sum price worked out by the contractor for (External Electric supply) as listed in Schedule 'A' Part-II against the lump sum price inserted by the MES. |
| 10 | Sch 'A' Part-III (External Water supply) Lump sum price worked out by the contractor for (External Water supply) as listed in Schedule 'A' Part-III against the lump sum price inserted by the MES. |
| 11 | Sch 'A' Part-IV (Road Path Culvert) Lump sum price worked out by the contractor for (Road Path Culvert) as listed in Schedule 'A' Part-IV against the lump sum price inserted by the MES. |
| 12 | Sch 'A' Part-V (Sewage Disposal) Lump sum price worked out by the contractor for (Sewage Disposal) as listed in Schedule 'A' Part-V against the lump sum price inserted by the MES. |
| 13 | Sch 'A' Part-VI (Area Drainage) Lump sum price worked out by the contractor for (Area Drainage) as listed in Schedule 'A' Part-VI against the lump sum price inserted by the MES. |
| 14 | Sch 'A' Part-VII (Security Fencing & Gate) Lump sum price worked out by the contractor for (Security Fencing & Gate) as listed in Schedule 'A' Part-VII against the lump sum price inserted by the MES. |
| 15 | Sch 'A' Part-VIII (Rain Water Harvesting) Lump sum price worked out by the contractor for (Rain Water Harvesting) as listed in Schedule 'A' Part-VIII against the lump sum price inserted by the MES. |
| 16 | Sch 'A' Part-IX (Arboliculture) Lump sum price worked out by the contractor for (Arboliculture) as listed in Schedule 'A' Part-IX against the lump sum price inserted by the MES. |
| 17 | Sch 'A' Part-X (FIRE FIGHTING SYSTEM) Lump sum price worked out by the contractor for (FIRE FIGHTING SYSTEM) as listed in Schedule 'A' Part-X against the lump sum price inserted by the MES. |
| 18 | Sch 'A' Part-XI (Lighting Protection) Lump sum price worked out by the contractor for (Lighting Protection) as listed in Schedule 'A' Part-XI against the lump sum price inserted by the MES. |
| 19 | Sch 'A' Part-XII (Summer & cooling Appliances) Lump sum price worked out by the contractor for (Summer & cooling Appliances) as listed in Schedule 'A' Part-XII against the lump sum price inserted by the MES. |
| 20 | Sch 'A' Part-XIII (Site Clearance) Lump sum price worked out by the contractor for (Site Clearance) as listed in Schedule 'A' Part-XIII against the lump sum price inserted by the MES. |
| 21 | Note for Srl No 9 to 20The percentage above / below the SSR -2020 (part-II) rates shall be derived from the amount quoted by the contractor against Srl No. 9 to 20 by comparing it with the amount inserted / pre- priced by the department and the same shall be applicable for the items of respective schedule |
| 22 | Schedule 'A' Part-XIV (Miscellaneous items of works) |
| 23 | Sewage Disposal |
| 24 | Item No 01 : S & F of on site LLDPE Septic tank of 10 Users designed to carry sewage and sullage water, excavation in any type of soil, PCC 1:4:8 below foundation with vent shaft, manhole openings with cover connection etc complete all as specified and directed |
| 25 | Item No 02 : M&Lfor Soakage wells 1.2 X 1.5 m excavation, in any type of soil, foundation in PCC 1:3:6, walls of honey combed masonry with top ring of M25 concrete including intercepting chamber and screen chamber made of Brick masonary in CM, RCC cover slab in M25/ SFRC cover, interconnecting pipes of RCC/DWC complete filled with brick bats complete all as specified and directed |
| 26 | Arboliculture |
| 27 | Item No 03 : Plantation of tree of fruits/Herbal nature and taking care for three year after complition of work including watering providing manure/fertilizer etc complete all as directed.( Neem/Jamun/Ashoka/Mangoo/Amla ) |
| 28 | Summer & cooling Appliances |
| 29 | Item No 04 : Supply and fix Water heater (Geyser), storage type, electric,capacity 50 litres.BEE 5 star rated , Heating Element: 2000 W , Pressure Rating: High-pressure rating (8 Bar), Inner Tank Material: High-grade Stainless Steel or Glass-lined coated Steel (minimum thickness 1.5 - 2.0 mm)Outer Body Material: ABS plastic (rust-proof) or CRCA Mounting: HZ OR Vertical wall mounting, Safety Features: Multi-function safety valve (safety relief valve), thermal cut-off, connection pipe, ISI marked , Warranty: Minimum 2 years on product and 5 years on inner tank including all fixing clamps, nut, bolts etc and complete all as directed.. |
| 30 | Item No 05 : Supply and installation of Double Skin Puff Insulated Industrial Air Washer Unit having capacity 14725 cfm @ 0.00 or [email protected] INCH Static Pressure, providing 80% minimum cooling efficiency , sound pressure level @ 1m 72 db, cooling medium honeycomb pad, input power suply 415V, 3 phase, having 70 ltr water storage tank complete , AMCA Certified Blower Fan complete all as directed. |
| 31 | Item No 06 : Supply and installation of Double Skin Puff Insulated Industrial Air Washer Unit having capacity 11780 cfm@ 0.00 [email protected] INCHStatic Pressure providing 80% minimum cooling efficiency , sound pressure level@ 1m 72 db, cooling medium honeycomb pad, input power suply 415V, 3 phase, having 70 ltr water storage tank complete , AMCA Certified Blower Fan all as directed. |
| 32 | Item No 07 : S&F Air Supply Grill Supply & Installation of Powder Coated Double Louver Air Supply Grill with damper for air balancing and as directed. |
| 33 | Item No 08 : Supply & Fix Volume control damper complete all as specified. |
| 34 | Item No 09 : S&F Canvass connection complete all as specified and directed. |
| 35 | Item No 10 : M&L for Providing scaffolding for G+7 height building wk for execution of Duct work required for centralized air cooling system and complete all as specified. |
| 36 | Item No 11 : Auto Clean Kitchen Chimney, Baffle Filters, Touch Control with Motion Sensor 60/90cm 1200 m3/h - Silver (6078 MS AC) and all as directed. |
| 37 | Item No 12 : Supply and fix refrigerator, electric driven (single phase), capacity 310 Litres.BEE 5 star rated, R-134A/ R-410A,R-32 , Auto-defrost technology, double door,inverter Compressor – Energy efficient, less noise & more durable , Shelf Type: Toughened Glass complete all as specified and direcetd. |
| 38 | Item No 13 : S&F Bottled Water Dispenser with Cold, Hot & Normal Water, Durable & Sleek Design, Low Power Consumption, Environment Friendly aving option of dispensing hot and cold water with cooling capacity 3 ltrs/hr, heating capacity min 4 ltrs/hr and storage cabinet capacity minimum 14 ltr, working in R - 134a refrigerant all as specified and directed. |
| 39 | Item No 14 : S&F 3 phase starter for 3 H.P pumps for air coolong unit / duct cooler all as specified and directed. |
| 40 | Lighting Protection System |
| 41 | Item No 15 : S&F porceliene insulators 15 BMD type T with nut bolts / screws for fixing of aluminium strips on roof including provn of PCC of size 10cmX10cmX10cm height etc to avoid leakage of roof complete as directed. |
| 42 | Item No 16 : Earthing complete with galvanised steel earth plate 60×60cm ×3.15mm thick electrode earthing lead buried directly in ground vertically to a depth not less than 2.25 Mtr deep below ground level with top edge of the plate not less than 1.5 Mtr below normal ground level connected to and including galvanised iron strip 32×6mm by means of bolts, nuts, check nuts & washers etc made of GI and connected to earthing test point all as shown in electrical plate No. 5 of SSR Part I of 2009 & as specified or indicated and testing on completion including excation/earth work in any type of strata PCC ( 1:3:6 ) type C1 earthing chamber, pre cast slab 50 mm thick in cement concrete ( 1: 2 : 4 ) type B 1 ( reinforced with welded steel wire fabric (XPM) weight not less than 4 Kg / Sqm), cast iron frame, funnel with wire mesh,GI watering pipe of 20 mm bore medium grade and lugs, with and including galvanised iron strip 32×6mm with GI protection pipe of 15 mm medium grade 7.5 meter long, etc complete all as specified. |
| 43 | DG SET |
| 44 | Item No 17 : Supply and installation of silent Diesel Engine driven generating set 415 volts ,3 Phase 4 wire ,Engine as per IS :10001/10002 and alternator as per IS :13364 complete with foundation (as per OEM design),control panel with necessary meter and sound proof canopy as per CPCB norms of capacity 82.5 KVA or nearest standard size, 415 volts, 3 phase 4 wire, 1500 rpm, 50 Hz power supply with power factor 0.8 couple directly to alternator mounted on a common base plate complete with integral acoustic enclosure having silent features such as modular bolted construction with fabrication on imported CNC torret punch machines, |
| 45 | nine tank treatment process with pure polyster based powder coating to ensure long life in all weather conditions and for out door application/ installation, integrated design thereby facilitating /easy handling installation & shifting of the equipment at site. The design of integral acoustic enclosure should be any type approved by national Physical laboratory as per Central Pollution Control Board (CPCB-IV + Emmission compliant) latest norms/regulation Noise level 75dB(A) at a distance of one meter with fuel tank, battery and standard accessories as recommended by manufacturer, vibration pad, sand cushioning around PCC foundation, tools and spares, as provided by manufacturer all as specified and as directed with the following specifications of :- |
| 46 | ENGINE - 4 cylinders, inline, 4 stroke cycle, Water cooled. The engine shall be provided with electrical starting arrangement & shall give the electrical output 82.5 kva at 0.8 power factor, 415Volts at the alternator terminal. |
| 47 | ALTERNATOR: single bearing alternator suitable for continuous operation generating 82.5 KVA at 1500 RPM, 415Volts , 0.8 power factor (lag) suitable for 50 Hz, 3 phase, 4 wire system, confirming to BS 5000/ IS 4722. The alternator is brushless type, screen protected, revolving field, self excited alternator confirming to IS/IEC 60034-1, self regulated through an AVR. The alternator has the following features: a) ± 0.50% voltage regulation (max.) in static conditions (b) IP: 23 protection with insulation class H. |
| 48 | (c) Permissible overload of 10% for one hour in 12 hours of operation. (d) 3 phase reconnectable winding with 12 terminal brought out for connection. (e) dedicated winding speecially designed for 1 phase operation (f) double layer lap startor winding (g) PCC foundation complete as per manufacturer's design including anti vibration pads, necessary excavation & earth work in soft/loose, sand cushioning, grouting foundation etc. |
| 49 | Features, Functions, Protections(a) 16 character x 2 line alphanumeric LCD display with LED backlight (b) Operator interface (c) Provide a record of most recent fault conditions. Fault history stored in the control non volatile memory (d) Provide Alternator data fequency Control includes provision for Service adjustment and calibration of DG control functions(a)Voltage, frequency selection(b)Meter calibration(c)Configurable input and output set up PowerStart operates on 12 V DC batteries Auto start mode accepts a ground signal from remote devices to automatically start the DG set. The remote start will also wake up the control system from sleep mode. |
| 50 | Engine Starting – The control system supports automatic engine starting, Primary and back up start disconnects are achieved by battery charging alternator feedback or main alternator output frequency. Controller provide configurable time delay of 0-300 sec to start after remote start signal and time delay of 0-600 secs prior to shutdown after stop signal. Sleep mode increase battery life. Configurable current settings from low to minimize current draw when genset is not working. |
| 51 | Engine Protective Functions includes - Configurable alarm outputEmergency stop: Annunciated whenever an emergency stop signal is received by the control(a).Low Lube oil pressure warning and shutdown(b)High engine water temperature warning/ shutdown(c) Low coolant temp warning (d) Sensor failure indication(e)Low and high battery voltage warning (f) Weak battery warning (g) Fail to start shut down(h) Cranking lockout: Control will not allow the starter to engage or to crank the running engine(j) Cyclic cranking : Configurable for the number of starting cycle (1 to 7) and duration of crank and rest periods.Alternator Protective functions includes : (l) High and Low AC voltage shut down (m) Under and over frequency shutdown / warning (n) Loss of sensing voltage input shut down (o) Battery charger alternator |
| 52 | Fuel tank: Sub Base Fuel tank of 14 SWG MS sheet of adequate capacity min.140 litre (b) Base Rail: Base Rail with integral fuel tank is provided. Batteries: For electrical control circuit ,12 Volts/88 AH battery for electrical starting of DG set |
| 53 | AMF ELECTRICAL CONTROL PANEL : AMF Panel is manufactured with 14/16 guage fabricated out of 2mm thick CRCA sheet, floor mounting type, powder coated for weather-proof and long lasting finish, totally enclosed, front higed cover, instrument swithches and panel complete all as specified and required. Control Panel (Manual / AMF), where applicable, shall be equipped with suitable Voltmeter, Ammeter, Frequency meter, power factor meter (these items can be alternatively supplied in one multifunctional digital display meter), battery charger, indicators, various switches and cutout / MCB / MCCB / Contactor / Circuit breaker for the DG output of appropriate rating and accuracy class as per trade practice for better utility |
| 54 | One set of accessories (As per manufacture's instruction) :- |
| 55 | (aa) Fuel tank with locking arrangement |
| 56 | (ab) Level indicator on fuel tank |
| 57 | (ac) Drain plug |
| 58 | (ad) MS class \\"C\\" piping , suitable dia and length for fuel inlet from tank to engine as per manufactures instruction. |
| 59 | (ae) Fuel strainer and fuel tank with air vent. |
| 60 | (af) Batteries Low Maintenance free to IS: 14257 for high cranking performance\\" heavy duty 12 Volts 80 AH , fully charged, indication of high flow charing changed : - 01 Nos |
| 61 | (ag) Cable connection from alternator to DG set control panel as directed |
| 62 | Tools (As per manufactures instructions):- |
| 63 | (aa) 'D' spanners - 01 Set |
| 64 | (ab) Ring spanners - 01 Set |
| 65 | (ac) Screw diver 5\\" to 12 \\" - 01 Set |
| 66 | (ad) Cutting plier 9 \\" - 01 No |
| 67 | (ae) Hammer 2 LBS - 01 No |
| 68 | Base frame arrangements . The engine and alternator would be coupled by means of specially designed flexible coupling and both the units including the radiator would be mounted on a rigid fabricated base as per OEM to form a compact arrangement. |
| 69 | Sound acoustic enclosure : CPCB approved sound acoustic enclosure sutable for above genrator set with complete set installed within canopy. |
| 70 | External Electric supply |
| 71 | Item No 18 : M& L for cable root indicator MS sheet embossed with LT 1100 Volts Volts UG made with CI Plate 6 mm thick fixed with MS angle Iron of size 30x30x4mm of length 400 mm long including PCC work 1:2:4 type B1 of size 150x150x150 mm complete all as specified & directed |
| 72 | Item No 19 : M& L for cable root indicator MS sheet embossed with HT 11000 Volts UG made with CI Plate 6 mm thick fixed with MS angle Iron of size 30x30x4mm of length 400 mm long including PCC work 1:2:4 type B1 of size 150x150x150 mm complete all as specified & directed |
| 73 | Item No 20 : Supply, installing, testing and commissioning out door type LT Panel (MAIN PANEL) of suitable size, Floor mounted, CPRI approved factory made totally enclosed, dust and vermin proof, shutter in front and in rear side made of 3.15 mm thick CRCA sheet, duly fabricated and having proper locking arrangement in both front and rear door with 4 side slanting roof duly projected and painted to both internal and external surfaces with powder coating paint in heat process of sheet and suitable for 500 volts, 50 Hz, 3 phase 4 wire system and comprising with and including following accessories and mounted on PCC Plat form made out of PCC 1:3:6, 100 mm thick, 1 Mtr all round the panel board complete with the following items housed in : - |
| 74 | BUSBAR :- (i) 600 Amps rated Aluminium bus bar TPN duly insulated with coloured PVC sleeve as per standard colour code and rigidly mounted on bakelite/DMC insulator bus bar support (Square/round) insulators of suitable size and good insulation resistance |
| 75 | INCOMING :- |
| 76 | (a) MCCB 4 Pole 500 Amps,ACB 36 KA with Rotary Handle, microprocessor release adjustable amp Ics = 100% Icu as per IEC 60947-2 , Adjustable Over load from 0.5 to 1*In , Adjustable Short Circuit from 2 to 10*Ir , Adjustable Neutral Protection - N, N/2,OFF for 4 Pole MCCB , Inbuilt Thermal Memory- 01 No (incoming) |
| 77 | (b) Digital Voltmeter 3 Phase Class-1 50Hz - 01 No. |
| 78 | (c) Digital Ammeter 3 Phase Class-1 50Hz - 01 No. |
| 79 | (d) Indicator Lamps (LED type) & bakelite fuseshowing R,Y, G phase - 01 set |
| 80 | (f) Copper wound with CTR - 03 Nos |
| 81 | OUT GOING |
| 82 | (i) MCCB 4 Pole 250 Amps,25 KA at 415 volts - 01No.(NCO) |
| 83 | (i) MCCB 4 Pole 160Amps,25 KA at 415 volts - 01No.(JCO) |
| 84 | (ii) MCCB 4 P 63 Amps, 16 KA 415 volts - 01 Nos |
| 85 | (ii) Indicator Lamps (LED type) & bakelite fuse showing R,Y, B phase - 02 set |
| 86 | Item No 21 : Supply, installing, testing and commissioning out door type LT Panel (DG SET ) of suitable size, Floor mounted, CPRI approved factory made totally enclosed, dust and vermin proof, shutter in front and in rear side made of 3.15 mm thick CRCA sheet, duly fabricated and having proper locking arrangement in both front and rear door with 4 side slanting roof duly projected and painted to both internal and external surfaces with powder coating paint in heat process of sheet and suitable for 500 volts, 50 Hz, 3 phase 4 wire system and comprising with and including following accessories and mounted on PCC Plat form made out of PCC 1:3:6, 100 mm thick, 1 Mtr all round the panel board complete with the following items housed in : - |
| 87 | BUSBAR :- (i) 100Amps rated Aluminium bus bar TPN duly insulated with coloured PVC sleeve as per standard colour code and rigidly mounted on bakelite/DMC insulator bus bar support (Square/round) insulators of suitable size and good insulation resistance |
| 88 | INCOMING :- |
| 89 | (a) MCCB 4 Pole 63 Amps,10KA with Rotary Handle, microprocessor release adjustable amp Ics = 100% Icu as per IEC 60947-2 , Adjustable Over load from 0.5 to 1*In , Adjustable Short Circuit from 2 to 10*Ir , Adjustable Neutral Protection - N, N/2,OFF for 4 Pole MCCB , Inbuilt Thermal Memory- 01 No (incoming) |
| 90 | (b) Digital Voltmeter 3 Phase Class-1 50Hz - 01 No. |
| 91 | (c) Digital Ammeter 3 Phase Class-1 50Hz - 01 No. |
| 92 | (d) Indicator Lamps (LED type) & bakelite fuseshowing R,Y, G phase - 01 set |
| 93 | (f) Copper wound with CTR - 03 Nos |
| 94 | OUT GOING |
| 95 | (i) MCCB 4 Pole 32 TPN Amps,10 KA at 415 volts - 02No. |
| 96 | (ii) MCB 4 P 32 SPN Amps, 10KA 415 volts - 01 Nos |
| 97 | (ii) Indicator Lamps (LED type) & bakelite fuse showing R,Y, B phase - 02 set |
| 98 | Item No 22 : Supply, installing, testing and commissioning out door type LT Panel (NCO BLDG ) of suitable size, Floor mounted, CPRI approved factory made totally enclosed, dust and vermin proof, shutter in front and in rear side made of 3.15 mm thick CRCA sheet, duly fabricated and having proper locking arrangement in both front and rear door with 4 side slanting roof duly projected and painted to both internal and external surfaces with powder coating paint in heat process of sheet and suitable for 500 volts, 50 Hz, 3 phase 4 wire system and comprising with and including following accessories and mounted on PCC Plat form made out of PCC 1:3:6, 100 mm thick, 1 Mtr all round the panel board complete with the following items housed in : - |
| 99 | BUSBAR :- (i) 400Amps rated Aluminium bus bar TPN duly insulated with coloured PVC sleeve as per standard colour code and rigidly mounted on bakelite/DMC insulator bus bar support (Square/round) insulators of suitable size and good insulation resistance |
| 100 | INCOMING :- |
| 101 | (a) MCCB 4 Pole 250 Amps, 25 KA with Rotary Handle, microprocessor release adjustable amp Ics = 100% Icu as per IEC 60947-2 , Adjustable Over load from 0.5 to 1*In , Adjustable Short Circuit from 2 to 10*Ir , Adjustable Neutral Protection - N, N/2,OFF for 4 Pole MCCB , Inbuilt Thermal Memory- 01 No (incoming) |
| 102 | (b) Compartment for Installing 4 nos. star delta starter 3 phase required for centralise air cooling |
| 103 | (c) Digital Voltmeter 3 Phase Class-1 50Hz - 01 No. |
| 104 | (d) Digital Ammeter 3 Phase Class-1 50Hz - 01 No. |
| 105 | (e) Indicator Lamps (LED type) & bakelite fuseshowing R,Y, G phase - 01 set |
| 106 | (f) Copper wound with CTR - 03 Nos |
| 107 | OUT GOING |
| 108 | (i) MCCB 4 Pole 100 Amps,10 KA at 415 volts - 01No. |
| 109 | (ii) MCCB 4 P 63 Amps, 10KA 415 volts - 04 Nos |
| 110 | (ii) MCB 4 P 6 Amps, 10KA 415 volts - 04 Nos |
| 111 | (ii) Indicator Lamps (LED type) & bakelite fuse showing R,Y, B phase - 02 set |
| 112 | Item No 23 : Supply, installing, testing and commissioning out door type LT Panel (JCO BLDG ) of suitable size, Floor mounted, CPRI approved factory made totally enclosed, dust and vermin proof, shutter in front and in rear side made of 3.15 mm thick CRCA sheet, duly fabricated and having proper locking arrangement in both front and rear door with 4 side slanting roof duly projected and painted to both internal and external surfaces with powder coating paint in heat process of sheet and suitable for 500 volts, 50 Hz, 3 phase 4 wire system and comprising with and including following accessories and mounted on PCC Plat form made out of PCC 1:3:6, 100 mm thick, 1 Mtr all round the panel board complete with the following items housed in : - |
| 113 | BUSBAR :- (i) 250Amps rated Aluminium bus bar TPN duly insulated with coloured PVC sleeve as per standard colour code and rigidly mounted on bakelite/DMC insulator bus bar support (Square/round) insulators of suitable size and good insulation resistance |
| 114 | INCOMING :- |
| 115 | (a) MCCB 4 Pole 160 Amps, 25 KA with Rotary Handle, microprocessor release adjustable amp Ics = 100% Icu as per IEC 60947-2 , Adjustable Over load from 0.5 to 1*In , Adjustable Short Circuit from 2 to 10*Ir , Adjustable Neutral Protection - N, N/2,OFF for 4 Pole MCCB , Inbuilt Thermal Memory- 01 No (incoming) |
| 116 | (b) Compartment for Installing 9 nos. star delta starter 3 phase required for centralise air cooling |
| 117 | (c) Digital Voltmeter 3 Phase Class-1 50Hz - 01 No. |
| 118 | (d) Digital Ammeter 3 Phase Class-1 50Hz - 01 No. |
| 119 | (e) Indicator Lamps (LED type) & bakelite fuseshowing R,Y, G phase - 01 set |
| 120 | (f) Copper wound with CTR - 03 Nos |
| 121 | OUT GOING |
| 122 | (i) MCCB 4 Pole 63 Amps, 10KA at 415 volts - 03No. |
| 123 | (ii) Indicator Lamps (LED type) & bakelite fuse showing R,Y, B phase - 02 set |
| 124 | (iii) MCB 4 P 6 Amps, 10KA 415 volts - 09 Nos |
| 125 | Item No 24 : Supply and fix cable jointing kit for 1.1 KV grade cable for straight through joint complete with Jointing material heat Shrink type and accessories suitable for 3 ½ / 4 core XLPE, armoured, Al conductor cable of size 120 to 150 sqmm,Indoor/Outdoor type |
| 126 | Item No 25 : Supply and fix cable jointing kit for 1.1 KV grade cable for straight through joint complete with Jointing material heat Shrink type and accessories suitable for 3 ½ / 4 core XLPE, armoured, Al conductor cable of size 300 to 400 sqmm,Indoor/Outdoor type |
| 127 | Item No 26 : S & F Integral decorative LED bollard with IP 65/66 protection suitable for 10 watts LED with necessary elecrical connections with adequate size of Nuts and Bolts including junction box with 6-32 A MCB of size complete as all specified and as directed. |
| 128 | Item No 27 : Earthing complete with galvanised steel earth plate electrode 60 cm x60 cm x 6 mm thick buried directly in ground ,(Earth pit not less than 2.25 meter deep below ground level) with top edge of plate not less than 1.5 meter below normal ground level ,connected to and including galvanised iron earth strip 32x 6 mm by means of nut, bolts, check nuts and washers of galvanised iron or steel complete all as specified and directed including testing on completion including the material and labour of the following : - (a) Excavation and earth work for drilling hole for electrode in any type of Soil. (b) reinforced with welded steel wire fabric weighing not less than1.87 Kg/ Sq meter. (c) Funnel with watering pipe of GI 20 mm nominal bore light grade and lugs etc complete all as specified and directed (d) 40 mm nominal bore medium grade GI protection pipe 5 meter long for protection of earthing lead complete all as specified and directed. (e) Requisite quantity of common salt and charcoal. (f) Testing of earthing. |
| 129 | Earthing complete with galvanised steel earth plate electrode 60 cm x60 cm x 6 mm thick buried directly in ground ,(Earth pit not less than 2.25 meter deep below ground level) with top edge of plate not less than 1.5 meter below normal ground level ,connected to and including galvanised iron earth strip 25 X 4 mm by means of nut, bolts, check nuts and washers of galvanised iron or steel complete all as specified and directed including testing on completion including the material and labour of the following : - (a) Excavation and earth work for drilling hole for electrode in any type of Soil. (b) reinforced with welded steel wire fabric weighing not less than1.87 Kg/ Sq meter. (c) Funnel with watering pipe of GI 20 mm nominal bore light grade and lugs etc complete all as specified and directed (d) 40 mm nominal bore medium grade GI protection pipe 5 meter long for protection of earthing lead complete all as specified and directed. (e) Requisite quantity of common salt and charcoal. (f) Testing of earthing. |
| 130 | Item No 28 : Supply and fix junction box made out of polycarbonate with IP 55/IP 65 protection of size 155 x 210 x 92 mm,having terminals for termination of cable with necessary nuts and bolts , including -02 Nos polycarbonate cable gland , 01 Nos DIN rail for mounting of MCB and 01 No, MCB SP, 10 KA, 6 Amps in and including fixing clamp of FI 50 x 6mm with necessary nuts and bolts complete all as directed. |
| 131 | FIRE FIGHTING SYSTEM |
| 132 | Item No 29 : Supply and fix hose Pipe 01x30 Meter length 63 mm dia as per IS 884 including Nozzle , coupling all fitting accessories required at site Hose pipe shall be rubber lines woven jacketed and 63mm in diameter.They shall conform to type-2 (Reinforced rubber lined) of IS:639-1979. The hose shall be sufficiently flexible and capable of being rolled.Each run of hose pipe shall be complete with necessary coupling at the ends to matchwith the landing valve or with another run hose pipe or with Branch pipe. The couplings shall be of instantaneous spring lock type. Branch pipe shall be of gunmetal 63mm dia and be complete with male instantaneous spring lock type coupling for connection to the hose pipe. The branch pipe shall be externally threaded to receive the nozzle. |
| 133 | The nozzle shall be of copper or gunmetal, 20mm in internal diameter. Thescrew threads at the inlet connection shall match with the threading on the branch pipe,the inlet end shall have a hexagonal head to facilitate screwing of the nozzle on to the branch pipe with nozzle spanner.End couplings, branch pipes, and nozzles shall conform to IS:903-1985, two hoses of 15 mtr Or 1X30m hose. Lengths with couplings shall be provided with each external (yard) hydrant. One nozzle and one branch pipe with coupling shall be provided with each yard hydrant complete all as specified and directed. |
| 134 | Item No 30 : Supply and fix automatic air release valve50mm dia suitable for domestic water with 50mmgunmetal stop valve complete. |
| 135 | Item No 31 :Supply only of fire extinguiser ISI marked CO2 type Fire Extinguisher 4.5 KG capacity conforming to IS : 15683 :2006 (old IS : 2878) made from seamless cylinder conforming to IS : 7285 duly approved by chief controller of explosive , Nagpur fitted with ISI Marked Controlled valve conforming to IS : 3224 , high pressure 1 mtr long discharge hose and horn complete with initial gas charged with carrying handle and wall mounting bracket, , suitable for operating between 30 degree centrigrade to + 55 degree centigrate, Fire Rating Class - 138. |
| 136 | Item No 32 : Supply and fix pressure sensor switch having ambient operating tem -40 to 65 degree celcius , differential pressure range 0.7 bar to 4 bar , regulation range 0.2 bar to 7.5 bar ISO STANDADARD 228-1 complete all as specified and as directed. |
| 137 | Item No 33 : Supply only of stored pressure fire extinguiser ISI marked powder type Fire Extinguisher 6 KG capacity suitable for Class \\"A\\", \\"B\\", \\"C\\" Fire consisting with discharge hose and nozzle of welded cylinder, squeeze lever discharge valve fitted with pressure indicating guage, internal discharge tube, discharge nozzle suspension bracket conforming to IS : 15683 :2006 (old IS : 2878) duly charged with ISI Marked Mono Ammoniumphosphate base ABC powder conforming to IS : 14609 and pressurized with Nitrogen Gas, suitable for operating between 30 degree centrigrade to + 55 degree centigrate, Fire Rating Class - 1A & 13B |
| 138 | Item No 34 : Supply and fix various sign board features a photo-luminescent coating that absorbs light and glows bright green if power fails. It should be highly durable and a great safety backup. Dimension 100 X 150 mm and complete all specified as directed |
| 139 | FIRE ALARM SYSTEM |
| 140 | Item No 35 : S & F testing & Commission of CONVENTIONAL with Digital Display fire control Panel with per BN 54 two loop Panel of capacity for 99 Detector & 99 Module upto 200 detector & modules fitting per loop with autoatic battery charger including Maint free battery , including lamp with all connected accessories 1 Zone. complete all as specified. |
| 141 | Item No 36 : S & F including Testing, Commmessioning of conventional Manual call point resettable type complete all as specified.. |
| 142 | Item No 37 : Earthing complete for various equipments with galvanised steel earth plate electrode 600 x 600 x 6mm thick directly burried in the ground (earth pit not less than 2.25 metre deep below ground level) with top edge of earth plate not less than 1.5 m below the ground level, connected to G.I wire 4 mm by means of bolts, nuts, check nuts and washers of galvanised iron or steel, GI pipe 20mm , bore light grade for protection of earthing strip, PCC chamber 1:4:8, type C-1 using 20mm graded stone aggregate, internal surface of concrete chamber plastered with 12mm thick plaster in CM 1:4, funnel with wire gauge of 22 gauge ( 0.63) 8 mesh per linear inch, |
| 143 | 50mm thick cover of RCC 1:2:4, type B-1, using 20mm graded stone aggregate, reinforced with 8mm TMT bar at 100mm center to center both ways and charcoal dust and common salt all as shown in electrical plate No. 3 of MES SSR Part-I and as specified including excavation and earth work and connecting the earthing to an earthing test point as specified and testing on completion all as specified & directed by Engineer-in-Charge..Note:- Unit rate quoted is inclusive of earth lead and protection pipe upto 7.5 metre from earth plate. |
| 144 | Item No 38 : S & F for conventional fire Alarm Sounders/ sirens Electronic type horizontal two stage continous normal operation for atlast 50 minutes with sound level 65 DB to 120 DB measured at 105m with sound out put variation of + 5 DB upto 500 mtr range complete all as specified.. |
| 145 | Item No 39 : M & L for submain wiring for Manual Call point/hooter using approved colour coding as per IS with mutistranded FRLS copper conductor (1.5 sqmm) two core PVC insulated & unsheathed cable in & including MS Conduit heavy duty including fitting, MS junction boxes & accessories, & all as per requirment of manufacture.note: two run of FRLS copper conductor 1.5 sqmm and one run of MS conduit will be measured as one RM |
| 146 | External Water supply |
| 147 | Item No 40 : Supplying and laying 80 mm bore Ductile Iron Pressure Pipes, Centrifugally Cast [Spun], Class \\"K-7\\" with spigot and socket conforming to IS - 8329 in standard lengths with inside Cement Mortar Lining and Black Bitumen external coating and including necessary DI Specials & nitrile ribber as required complete all as specified and as directed. |
| 148 | Item No 41 : M&L for tapping in existing DI pipe lines 150 mm dia and inserting tee of 150x 100 mm and all as directed. |
| 149 | Item No 42 : Construction of brick masonry valve pit of size 900 mm x 900mm x 900 mm (internal dimensions) with one brick thick wall in cement mortar 1 : 4 on 100 mm thick PCC 1:4:8 type D2 (using 40mm graded broken stone aggregate) as in foundation lean concrete, including PCC 1:3:6 type C-1 (using 20mm graded crushed stone aggregate) as in benching and coping and 10mm thick cement plaster in CM (1:4) internally and externally upto 15cm below ground level providing valve pit cover 40x40x6mm angle iron frame all-round fixed by means of 4 Nos holdfast 150mm long made out of flat iron 40x6mm embedded in PCC block (1:2:4) type B-1 (using 20mm graded crushed stone aggregate) of size 230x200x100mm incl provn of hinges welded with angle iron frame and MS cover 3mm thck sheet, MS handle of suitable length and size welded with MS cover and suitable locking arrangement and applying two coats of synthetic enamel paint over a coat of red oxide primer including necessary excavation and earth work in soft/loose soil complete all as shown on drawing and as specified. Please Enable Macros to View BoQ information Schedule 'A' Part II (External Electric supply) Item Description of Item Unit Rate per Unit (Rs.) Qty Amount (Rs.) |
| 150 | Item No 42 : Construction of brick masonry valve pit of size 900 mm x 900mm x 900 mm (internal dimensions) with one brick thick wall in cement mortar 1 : 4 on 100 mm thick PCC 1:4:8 type D2 (using 40mm graded broken stone aggregate) as in foundation lean concrete, including PCC 1:3:6 type C-1 (using 20mm graded crushed stone aggregate) as in benching and coping and 10mm thick cement plaster in CM (1:4) internally and externally upto 15cm below ground level providing valve pit cover 40x40x6mm angle iron frame all-round fixed by means of 4 Nos holdfast 150mm long made out of flat iron 40x6mm embedded in PCC block (1:2:4) type B-1 (using 20mm graded crushed stone aggregate) of size 230x200x100mm incl provn of hinges welded with angle iron frame and MS cover 3mm thck sheet, MS handle of suitable length and size welded with MS cover and suitable locking arrangement and applying two coats of synthetic enamel paint over a coat of red oxide primer including necessary excavation and earth work in soft/loose soil complete all as shown on drawing and as specified. Please Enable Macros to View BoQ information Schedule 'A' Part II (External Electric supply) Item Description of Item Unit Rate per Unit (Rs.) Qty Amount (Rs.) |
| 151 | Supply, laying & testing cable XLPE insulated, screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables Earthed(heavy duty)with stranded aluminium conductor,as per relevance IS code 11000 volts grade, of size 3 core 120 Sqmm.and complete all as specified |
| 152 | Supply and laying & testing and commisioning LT underground cable 1100 volts grade, XLPE insulated and PVC sheathed heavy duty armoured with multi staranded aluminium conductor laid in pipes, trenches/ducts, on poles etc of the under mentioned type and sizes and as per relevance IS code complete all as specified and directed :- (a) 3.5 core x 400 sqmm RM 1539.12 20.0 30782.4 (b) 3.5 core x 185 sqmm RM 801.84 120.0 96220.8 (c) 3.5 core x 95 sqmm RM 453.98 180.0 81716.4 (d) 3.5 core x 50 sqmm RM 292.78 180.0 52700.4 (e) 2 core x 6 sqmm (Garden lighting & Post top Lantern) RM 127.61 200.0 25522.0 (f) 4 Core X 4 Sqmm (Centralised Cooler) RM 135.14 610.0 82435.4 |
| 153 | Excavation in trenches not exceeding 1.5m deep & not exceeding 1.5m wide or area not exceeding 10 Sqm on plan, in any type of soil and getting out for foundation, trenches or laying of electric cable or pipes complete all as specified and as directed. |
| 154 | Returning, filling in, excavated soil including spreading, levelling, watering and well ramming in layers not exceeding 25cm thick complete all as specified and as directed. |
| 155 | Removal of excavated materials (soil) to a distance not exceeding 50 m and depositing where directed at a level not exceeding 1.5 m above the starting point complete all as specified and as directed. |
| 156 | M&L dry river washed and screened dry sand for filling in trenches below and around the cable for cushioning including punning down as specified inrelevant clause of SSR Part I complete all as specified and directed. Note:- Punned thickness shall only be measured and paid. |
| 157 | Supplying and laying unreinforced precast concrete cable cover, class LV Type 2 flat, size 300mm x 180mm x 40mm complete all as specified and directed. |
| 158 | M&L for PCC (1:2:4) type B2 using 20 mm graded stone aggregate as in foundation, filling, mass concrete and pilasters, buttresses columns, posts etc complete all as specified & directed. |
| 159 | M&L for Precast Cement Concrete(RCC) 1:4:8 type D2 using 40 mm graded stone aggregate as in landings, cover slab (for manholes etc) and similar work including necessary form work and minimum reinforcement as per relevant IS code and set in CM 1:6 complete all as specified and directed. |
| 160 | M&L for PCC (1:3:6) type B2 using 20 mm graded stone aggregate as in foundation, filling, mass concrete and pilasters, buttresses columns, posts etc complete all as specified & directed. |
| 161 | Supply and fixing HT 11 KV (Earthed) grade cold shrinkable end termination jointing kit outdoor type complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 120 -185 sqmm complete all as specified and as directed. |
| 162 | Materials and labour for Aluminum conductor steel reinforced (ACSR) conductor of size stranded 7/1.6min as in LT overhead electric line and stretching the same with required span, standard sag and binding the conductor with pin/shackle insulator and jumpers with aluminum binding wire not less than 2.00mm dia, PG clamp etc complete all as specified and as directedluminum coMaterials and labour for Aluminum conductor steel reinforced (ACSR) conductor as in LT overhead electric line and stretching the same with required span, standard sag and binding the conductor with pin/shackle insulator and jumpers with aluminum binding wire not less than 2.00mm dia, PG clamp etc complete all as specified and as directednductor steel reinforced (ACSR) conductor as in LT overhead electric line and stretching the same with required span, standard sag and binding the conductor with pin/shackle insulator and jumpers with aluminum binding wire not less than 2.00mm dia, PG clamp etc complete all as specified and as directed |
| 163 | Supply and fixing Pin type insulator, porcelain, vitreous, white, brown or green insulator including one galvanised mild steel spindle, two galvanised iron washers and one galvanised iron nut, 150mm height, 150mm dia for 11000 volts grade confirming to IS-2486 complete all as specified and as directed. |
| 164 | Supply and fixing of switch air break gang operated triple pole mechanically operated horizontal type out door with all other fittings/ accessories mounted on & including porcelain insulators and steel frame with operating mechanism worked from ground level with & including operating rod of 32mm dia GI pipe medium grade (ISI marked) with MS handle with locking arrangement, for current rating up to 200 Amp 11000 Volts including dropout fuse set 15 insulators to suit gang operated triple pole 11 KV switch, connecting, commissioning and testing on completion complete all as specified and directed. |
| 165 | Supply and erecting steel tubular swaged poles complete with cast iron base plate, finial taper plug , bolts, nuts & screws complete all as specified, type 410 SP - 55 of 11 mtr long including painting of pole with one coat red oxide primer & two coat of aluminum paint & embedded portion of pole shall be painted with two coat of black paint complete all as specified and as directed |
| 166 | S&F for lightning arrestor Expulsion type complete with all fittings, transmision/ distribution class , (RMS) discharge current 10 KA suitable for rated system voltage of 12 KV supply system with maximum continuous operating Voltage (MCOV) not less than 7.65 KV (RMS) with highly non linear ceramic resister made of Zinc Oxide in hermetically sealed container and mounting on poles including all necessary bolts, nuts and washers and making electric connection and testing on completion complete all as specified and directed.Make:- SCHNENIDER or BHEL or GE POWER or W/S INSULATORS or SOUTHERN INSULATORS or OBLUM as approved by GE. |
| 167 | Supply, installation, testing and commissioning of copper wound (double wound), step down transformer of capacity 315 KVA (Level 3), plinth/ floor mounted, OUT DOOR TYPE and conforming to IS 1180:2014, AC 3 phase 50 Hz, ONAN with external cooling tubes/ radiators, having no load voltage ratio 11/0.433 KV corresponding to principal tapping, delta connected primary side (11KV HV side) and star connected on secondary side (433V LV side) in accordance with vector symbol Dyn-11 (Vector Group), manual type off load tap changing facility on HT side to vary secondary voltage from +5% to -7.5% in steps of 2.5%, continuous rating of capacity 315 KVA . The transformer shall be complete with all standard fittings and accessories, gauges, first fill of transformer oil as per IS-335, ISI marked duly filtered & dehydrated etc. Transformer shall be mounted on and including suitable platform of approx size 2.0Mx 2.0Mx 1.50M high (outer dimension) built with 150mm thick PCC 1:5:10 type E2 using 40mm graded stone aggregate as in foundation extending 150mm on both sides of wall, |
| 168 | 350mm thick of brick masonry built in CM 1:6 using old size sub class 'B' bricks, brick masonry shall be 450mm below GL & 550mm above GL, exposed faces of brick work up to 15cm below normal ground level shall be plastered in CM 1:4 & flush in same mortar as the work proceeds on faces in contact with soil, floor shall be 100mm thick with PCC 1:2:4 type B-1 using 20mm graded stone aggregate, laid in bays over & including 100mm thick hardcore over approved earth filling, exposed plastered surfaces shall be given three coats of white wash including necessary excavation and earth work complete all as specified and directed. The unit rate of transformer shall also includes the cost of following accessories/ fittings (a) Externally hand operated off-circuit Tap switch with position indicator and locking device.(b) Conservator with oil gauge, filling hole with plug & drain hole with plug.(c) Under carriage with four plain rollers.(d) Oil filling hole cum air release plug - 01 No(e) Drain valve cum sampling valve - 01 No(f) Filter valve with plug - 01 No(g) Rating plate & Diagram plate - 01 No(h) Lifting lugs for Transformer - 02 Nos(j) Lifting lugs for lid - 02 Nos(k) Earthling terminals - 02 Nos(l) Thermometer pocket - 01 No Silica gel breather - 01 No(n) Temperature rise indicator in oil 40 deg centigrade and windings 45 deg centigrade. (o) Fitting accessories as per IS 1180 (Part-I) 2014 Level-3 and as per clause No 19.14.1.2 of SSR Part I.(p) Maximum losses of transformer shall be energy efficiency level 3 as per IS 1180 (Part-I) 2014.(q) Oil level gauge incl oil level min and max. (r) Exclusion vent – 01 No.(s) 6” Dial type thermometer with alarm and trip contact and maximum temp – 01 No.(t) Mounting arrangement shall be provided with two 75x40 mm channels 460mm long. u) Suitable plinth of height 1.5M above GL for installation of transformer.(v) Cable termination box on both sides (HV Side & LV Side for cable connections ).(w) Plinth required for mounting Transformer as per above description. Note:-(i) The contractor shall submit preliminary drawing for approval to GE .(ii) factory inspection before dispatch shall be done by the rep of accepting officer.(iii) Pre-Commissioning of transformer shall be undertaken as per IS: and by the SEI/EI/AEI/ rep of accepting officer. |
| 169 | Supply, fix for LED post top lantern 40 watt light fitting made of cast aluminium spigot housing with decorative opal acrylic diffuser with IP 65 protection complete with all accessories fixed on GI pipe 50 mm dia complete all as specified and directed. |
| 170 | S&F earth continuity conductor or main earth lead of 32 X 6 mm GI strip with saddles and fixing screw etc for roof conductor and down conductor fixed to wall on batten or recess or ground for connecting earthing to various equipments as required complete all as directed. |
| 171 | S&F earth continuity conductor or main earth lead of 25 X 3.15 mm aluminium strip with saddles and fixing screw etc for roof conductor and down conductor fixed to wall on batten or recess or ground for connecting earthing to various equipments as required complete all as directed. |
| 172 | Supply and fixing LED Solar street light fitting 36 Watt including galvanized steel pole in built, lithium ion battery, solar panel, charge controller with dusk down sensor with all connected accessories like nuts bolts clamps etc complete all as directed. Total carried over to BOQ Rs. 4373705.57 Signature of Contactor DY Dir(Contracts) Date: For Accepting Officer Schedule 'A' Part III (External Water supply) Item Description of Item Unit Rate per Unit (Rs.) Qty Amount (Rs.) |
| 173 | Supply laying and fixing of GI tubing of 50 mm dia medium grade ISI Marked with all necesary fittings laid in trenches complete all as specified and directed. |
| 174 | Supply laying and fixing of GI tubing of 20 mm dia medium grade ISI Marked with all necesary fittings laid in trenches complete all as specified and directed. |
| 175 | Excavation in trenches, n exc 1.5m wide and n exc 1.5m in depth , for foundation, etc or for shafts, wells, cesspits, manholes, pier holes,etc. n exc 10sqm on plan and n exc 1.5m in depth and getting out in any type of soil complete all as specified and as directed. |
| 176 | M/L for Returning , filling in, including spreading, leveling, watering and well ramming in layers not exc 25 cm complete all as specified and as directed. |
| 177 | M/L for Removing excavated material n exc 50m and depositing where directed at a level n exc 1.5m above the starting point complete all as specified and as directed. |
| 178 | S&F gun metal gate valve of following sizes screwed down high pressure with handle, Iron wheel (ISI marked) complete all as directed. |
| 179 | (a) 50mm bore |
| 180 | (c ) 20mm bore |
| 181 | Supplying, fixing and testing of cast iron Sluice valve PN1.0 as per IS-14846, body, dome, wedge-CI IS:210, rings -bronze IS:318, Spindle-SS IS:6603, Gland Paking greasy jute packing, fasteners-CS, Gasket- Natural rubber, nominal size DN-80 mm,both ends flanged , complete all as specified and directed by Engr-in-charge.Note : Suitable size flanges, Joints and jointing materials shall be included under this item. |
| 182 | S & F Centrigugal monoblock booster pump for 440 V, 3 Phase, 50 Hz Confirming to IS- 12469 :1988 With CI Casing bronze impeller and stainless steel shaft mounted on heavy duty bearings suitable for 440 volts, 3 phase, 50 Hz 30m head, 900 LPM discharge including suitable size automatic pressure maintained pump starter complete all as specified and as directed. Total carried over to BOQ Rs. 376771.62 Signature of Contactor DY Dir(Contracts) Date: For Accepting Officer Schedule 'A' Part IV (Road Path Culvert) Item Description of Item Unit Rate per Unit (Rs.) Qty Amount (Rs.) |
| 183 | Excavating over areas, n exc 1.5 m deep and getting out soft/loose Soil |
| 184 | Surface excavation n.exc (not exceeding) 30 cm deep and averaging 15cm deep and getting out in soft/loose soil |
| 185 | Add to (or deduct from) last item for every 3 cm or part thereof above or below 15 cm average depth in soft /loose soil |
| 186 | M & L Moorum/red bajri filling in floors or pavings, laid in layers n exc. 15 cm thick, spread, levelled and rammed including watering |
| 187 | Laying and compacting 150 mm thick (compacted thickness) Granular Sub Base Course (GSB) grading as per Grade I as specified Table 400-1 of MaRTH specifications for Road and Bridge works, 2013, in a single layer over compacted subgrade with naturasand, crushed gravel, crushed stone, crushed slagor combination thereof as per the grading required The materials are mechanically mixed, spread andleveling on the subgrade by using motor grader of adequate capacity, and rolling with vibratory roller of capacity 80-1 00 KN static weight for achieving required compaction density of atleast 98% of the Maximum Dry Density. Consolidating to required gradient and camber complete all as specified and directed with finished surface tolerances as per Table 900-1 of MaRTH specifications for Road and Bridge works, 2013 |
| 188 | M & L for Laying and compacting 150 mm thick (compacted thickness) WMM laid in two layers of 75 mm each Wet Mix Macadam (WMM) grading as pe table 400-13 of MoRTH specifications for Road and Bridge works 2013 manufactured in WMM plant material comprising of clean, crushed, graded aggregate and granular material premixed with wate to a dense mass, spreading with sensor paver and rolling with vibratory roller of capacity 80-1 OOKN static weight and consolidating to required gradien and camber complete all as specified and directed The finished surface tolerances to be as per Table 900-1 of MoRTH specifications for Road and Bridge works 2013 complete all as specified. |
| 189 | M&L premixed bituminous macadam laid/rolled and compacted to required gradient and camber with using 20 mm graded stone agg and paving bitumen 4% by the weight of total mix (consolidate thickness 75 mm or less as required ) complete all as specified and as directed. |
| 190 | Applying evenly a prime coat of Cationic Bitumen Emulsion SS1 confirming to IS: 8887 at a rate of application of 0. 7-1 kg/sqm on surface of WMM/WBM including preparation of WBM/WMM surfaces as specified in Table 500-3 of MoRTH specification for road and bridge works 2013, using mechanical sprayer complete including preparation of WBM/WMM surfaces all as specified and directed . |
| 191 | M & L for laying bituminous premix asphaltic semi dense concrete VG-30 avaraging 40mm consolidated thickness with 5.5% binder content by weight of total mix using asphalt mechanical mixer plant & consolidated with 8to 10 ton power road roller to reqd level gradient camber and super elevation. |
| 192 | Continuous edging with roughly squared sand stones of size 30 cm x 5 cm (30cm deep & 5 cm thickness), length of each patti not less than 60 cm Complete of using sand stone/Katni sone all as specified and directed. |
| 193 | M&L preparation of road surface and applying thermoplastic relflective paint in white or any tint marking of min 2 mm thick single coat as in center line and edge line road marking of 150/100 mm width using ''HOT MARK\\" thermoplastic modern propelled road marking machine as directed incl all ingredients such as blinder, glass beads, Titaniumdioxide calcium carabonate inter fillers thermroplastic requirement for glass beads shell be the Table No 650.4 of MOT specifications incl spraying of glass beads etc all as per manufactures instrustions and as directed |
| 194 | Cement concrete type D-2 1:4:8 (using 20 mm graded aggregate) as in foundation filling and mass concrete , sub base complete all as directed. |
| 195 | Material and labour for providing and laying 60mm thick factory made chamfered edge cement concrete paver block of M-35 grade with aproved colour, design & attern as in foothpath, parks, lawns, drive ways or light traffic arking etc. of required strenght, thickness & size / shape, made by table vibrating method using PU mould, laid in required colour & pattern over and including 50mm thick compacted bed of fine sand, compacting and proper embedding / laying of interlocking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with sand and cutting of paver blocks as per required size and pattern, finishing and sweeping extra cement complete all as specified and directed. |
| 196 | M&L PCC 1:2:4 type B-1 (using 20 mm graded stone agg) as in seismic and other similar bands, coping, bed block or similar work including necessary form work complete all as specified. |
| 197 | Providing and laying at or near ground level factory made kerb stone of M-25 grade cement concrete in position to the required line, level and curvature, jointed with cement mortar 1:3, including making joints with or without grooves (thickness of joints except at sharp curve shall not to more than 5 mm), including making drainage opening wherever required complete. |
| 198 | Supply and fixing in repair cat eye solar reflective type of metal body alloy of size 100mm x 100mm x 20mm with PAMA striplens reflector of model No. DA 972.0 fixed with and incl MS stud of suitable size as per manufactures instructions. |
| 199 | Supply and fixing in repair solar cat eye aluminum alloy shall (100% water proofing design according to 65) of size 125mm x 125mm x 25mm (shank 65mm) of high efficiency Mono rystafie solar panel 2.4V/ 0.3 watt one NI-ed rechargeable battery (1.2V/ 1600MA) consisting of super bright LED with 10,000 to 18,000 mcd completed as per manufactures instructions etc. all as specified and directed |
| 200 | S&F 600 mm bore Reinforced concrete pipes class NP3, laid and jointed complete with collars complete all as specified and directed. |
| 201 | M&L PCC 1:3:6 type C2, 40mm graded agg as in concrete bed to drain pipes including packing under, and haunching against the sides of pipes after they are laid and tested for 600 mm bore complete all as specified and directed. |
| 202 | S&F 450 mm bore Reinforced concrete pipes class NP3, laid and jointed complete with collars complete all as specified and directed. |
| 203 | M&L PCC 1:3:6 type C2, 40mm graded agg as in concrete bed to drain pipes including packing under, and haunching against the sides of pipes after they are laid and tested for 450 mm bore complete all as specified and directed. |
| 204 | Removing excavated material n.exc 50 m and depositing where directed at a level n.exc 1.5 m above the starting point. |
| 205 | Returning filling in including spreading levlling ,watering and well ramming in layers nexc 25cm thick complete all as specified and directed. Total carried over to BOQ Rs. 4734659.35 Signature of Contactor DY Dir(Contracts) Date: For Accepting Officer Schedule 'A' Part V (Sewage Disposal) Item Description of Item Unit Rate per Unit (Rs.) Qty Amount (Rs.) |
| 206 | Excavating in trenches in any type of soil , n exc 1.5 m wide and n. exc. 1.5 m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. n exc 10 sq m on plan and n exc 1.5 m in depth and getting out soil complete all as specified and as directed. |
| 207 | Excavating in trenches in any type of soil , n exc 1.5 m wide and exc. 1.5 m in deep and n.exc 3.0m deep for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. n exc 10 sq m on plan and getting out soil complete all as specified and as directed |
| 208 | Returning, filling in, including spreading ,leveling, watering and well ramming in layers n. exc 25 cm with soil complete all as specified and as directed. |
| 209 | Removal of excavated material (soil) to a distance exc 50 m n. exc 250 m and depositing where directed at a level n.exc 1.5 m above the starting point complete all as specified and as directed. |
| 210 | Supplying and laying and jointing for (SN 8) DWCPE 180mm (OD)/ 163 (ID) conforning to IS-16098:2013 part -I with and incl jointing materials complete complete all as specified and as directed. |
| 211 | M&L for concrete bed to drain pipes including packing under, and haunching against the sides of pipes after they are laid and tested in cement concrete 1:4:8 complete all as specified and as directed. |
| 212 | M&L for extra for forming fair finished drain or channel 30 cm inner girth in cement concrete, using ex- tra cement, including forms, moulds, mitred/ stopped ends etc. |
| 213 | M&L for Brick work with sub class B bricks straight or curved on plan exc. 6m mean radius built in cement mortar (1:4).complete all as specified and as directed. |
| 214 | M&L, 15mm thick rendering on any faces of stone, concrete or brick work in CM 1:4 surface finished even and fair complete all as specified and as directed. |
| 215 | Supply only water proofing compound. |
| 216 | M&L for cement concrete type C2 1:3:6 (40mm graded stone aggregate) in foundations, filling and mass concrete complete all as specified and as directed. |
| 217 | M&L for cement concrete 1:2:4 type B1 (20 mm graded stone aggregate) as in coping complete complete all as specified and as directed. |
| 218 | M&L Precast cement concrete Type B-1 1:2:4 (Using 20 mm graded stone aggregate) in landings, cover slabs (for manholes etc.) shelves and similar articles with plain faces and set in cement mortar 1:6 complete all as specified and as directed. |
| 219 | S&F TMT steel bars 6 to 8mm in reinforcement, cut to length, bent to shape required including cranking, bending spirally or hooping for columns, hooking ends and binding with MS wire (annealed not less than 0.9mm dia) all as specified and directed |
| 220 | S&F TMT steel bars 5mm dia and over, up to and including 10mm dia in stirrups spcers and binders. |
| 221 | M&L for Framed work such as grills, gratings, etc.. with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks and similar work conforming to Fe.290.Gde-E-165 |
| 222 | M&L for cement concrete type B2 , 1:2:4 using 40 mm gradded stone aggregate in surface channels and drains complete Total carried over to BOQ Rs. 1334455.68 Signature of Contactor DY Dir(Contracts) Date: For Accepting Officer Schedule 'A' Part VI (Area Drainage) Item Description of Item Unit Rate per Unit (Rs.) Qty Amount (Rs.) |
| 223 | Excavating in trenches, n exc 1.5 m wide and n exc 1.5 m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. n exc 10 sq m on plan and n exc 1.5 m in depth and getting out in any type of soil complete all as specified and directed. |
| 224 | M&L PCC in foundations, filling and mass-concrete type D2 (1:4:8) using 40 mm graded stone aggregate complete all as specified and directed. |
| 225 | M&L Brick work with sub class 'B' bricks straight or curved on plan exc 6m mean radius built in CM (1:6) all as specified |
| 226 | M & L 10mm thick rendering in CM 1:4 on fair faces of brick work or concrete surfaces and finished the surface even & smooth without using extra cement complete all as specified and directed. |
| 227 | M&L RCC M - 25 (Design Mix) (20mm graded agg) as in footing etc complete. |
| 228 | M&L RCC M - 25 (Design Mix) (20mm graded agg) as in walls, retaining walls, basement walls, and the like , of any thickness including attached pilaster and butresses, footing etc complete. |
| 229 | Use & wate formwork to sides of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits (if any) of foundation and plinth beams; and similar work; vertical or to batter |
| 230 | Use & waste formwork to faces of walls, retaining walls, abutments, parapets and staircase railings and similar work including attached pillasters, buttresses, etc.; vertical or to batter |
| 231 | M&L Precast cement concrete Type B-1 1:2:4 (Using 20 mm graded stone aggregate) in landings, cover slabs (for manholes etc.) shelves and similar articles with plain faces and set in cement mortar 1:6 complete all as specified and as directed. |
| 232 | M & L for Mild Steel TMT bar 10mm dia and over cut to length bent to shape required including cranking, bending spirally for hoping for columns hooking ends and binding with & including Mild Steel wire (annealed) not less than 0.9 mm dia or securing with clips complete. |
| 233 | Extra for forming fair finished drain or channel 40 cm inner girth in cement concrete, using ex- tra cement, including forms, moulds, mi- tred/stopped ends etc complete all as specified and directed. |
| 234 | M&L for PCC (1:2:4) type B-1 (using 20 mm graded stone aggregate) as in cills, PCC blocks, coping, bed plates, seismic and other similar bands, plinth bends, etc including weathering slightly rounded or chamfered angles and throuting, inclusing necessary form work etc complete all as specified and directed |
| 235 | Returning filling in including spreading levlling ,atering and well ramming in layers nexc 25cm thick complete all as specified and directed. |
| 236 | Removing excavated soil exc. 50m but not exceeding 250 m and depositing where directed at a level n exc. 1.5 m above the starting point complete all as specified and directed. Total carried over to BOQ Rs. 2033250.82 Signature of Contactor DY Dir(Contracts) Date: For Accepting Officer Schedule 'A' Part VII (Security Fencing & Gate) Item Description of Item Unit Rate per Unit (Rs.) Qty Amount (Rs.) |
| 237 | Excavating in post holes (or similar holes) each n exc 0.5 cu. m, getting out in soft /loose soil , returning, filling in and ramming earth or broken rubble mixed with earth around, in layers not exceeding 25 cm complete all as directed. |
| 238 | Excavating in trenches, n exc 1.5 m wide and n exc 1.5 m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. n exc 10 sq m on plan and n exc 1.5 m in depth and getting out in soft/loose soil complete all as specified and directed. |
| 239 | M&L PCC in foundations, filling and mass-concrete type D2 (1:4:8) using 40 mm graded stone aggregate complete all as specified and directed. |
| 240 | M&L PCC in foundations, filling and mass-concrete type B2 (1:2:4) using 40 mm graded stone aggregate for fixing of angle iron post complete all as specified and directed. |
| 241 | M&L RCC M - 25 (Design Mix) (20mm graded agg) as in footing, plinth beam etc complete. |
| 242 | M&L RCC (Design Mix) M-25 ( using 20 mm graded aggregate ) Columns, pillars, piers, posts and strutscomplete all as specified and directed. |
| 243 | M&L Rough finished flat surfaces of concrete formwork to sides of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits (if any) of foundation and plinth beams; and similar work; vertical or to batter complete all as specified and directed. |
| 244 | M&L Rough finished square/rectangular or polyganal surfaces of concrete formwork to sides of pillars, posts, struts, piers, columns and stanchions complete all as specified and directed. |
| 245 | M&L Brick work with sub class 'B' straight or curved on plan exc 6m mean radius built in CM (1:4) complete all as specified and directed. |
| 246 | M & L 10mm thick rendering in CM 1:4 on fair faces of brick work or concrete surfaces and finished the surface even & smooth without using extra cement complete all as specified and directed. |
| 247 | M&L for PCC (1:2:4) type B-1 (using 20 mm graded stone aggregate) as in cills, PCC blocks, coping, bed plates, seismic and other similar bands, plinth bends, etc including weathering slightly rounded or chamfered angles and throuting, inclusing necessary form work etc complete all as specified and directed |
| 248 | Material & Labour for applying Two or more coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm over new surfaces. |
| 249 | S&F for Hand rails, half round or other steel section or core for wooden hand-rail straight portion, drilled and countersunk for balusters running bars, for doors, balusters, nosing to steps including embeding in concrete and screwing etc. wind ties for roof including securing bolts;MS angle iron in \\"Y\\" shape posts and struts in fencing including cutting tops to shape as directed including cutting tops to shape as directed, drilling holes, notching for wire, etc.; flat iron fillets (for securing wire mesh etc.) including all necessary drilling, bolting or riveting, etc., and similar work conforming to Fe-290 Gde E-165 complete as directed. |
| 250 | S&F framed work as in doors or gates of angle or other section with gussest plates, rails, braces, etc, complete drilled for fixing and incl steel sheeting or other covering doors etc, to be prepared for hanging and sliding with and including either hooks and hinges or steel hanging door fittings and fixing complete conferming to gde Fe 410-w |
| 251 | Supply of Chain link MS galvanisd fencing, any size or type complete all as specified and directed |
| 252 | Fixing only chain link fencing including line wires, any mesh , size and type fixed to any type of standards, rails, straining bolts, etc., incliding provision of binding wire complete all as specified and directed |
| 253 | M&L two coat of synthetic enamel paint over new steel surface of any description over 10cm in width or grith not otherwise described over one coat red oxide primer incl preparation of surfaces complete. |
| 254 | M&L TMT bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips or welding. |
| 255 | M&L for mild steel TMT bars 5mm dia and over upto incl 10mm cut to length bent to shape as reqd ,as in stirrups and spacers complete all as specified and directed. |
| 256 | S&F for Galvanised. 2 strand, steel barbed wire 2 mm dia barbed with 2mm dia barbs at 75mm spacings and straining and fixing to any type of standard rails strain- ing bolts, including, securing or tying at crossings with and provision of galvanised mild steel wire, staples or steel pins, etc. as directed (each line wire to be measured) complete all as directed. |
| 257 | Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc 25 cm all as specified. |
| 258 | Removing excavated soil exc.50m but not exceeding 250 m and depositing where directed at a level n exc. 1.5 m above the starting point complete all as specified and directed. Total carried over to BOQ Rs. 2875295.83 Signature of Contactor DY Dir(Contracts) Date: For Accepting Officer Schedule 'A' Part VIII (Rain Water Harvesting) Item Description of Item Unit Rate per Unit (Rs.) Qty Amount (Rs.) |
| 259 | Earth work in excavation by mechanical means (Hydraulic excavator)/ in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m. |
| 260 | Earthwork in excavation by mechanical means over area in any kind of soil (exceeding 30 cm deep' 1.5 m in width as well as excedding 10 Sqm in plan area) including getting out and disposal of excavated earth lead up to 50 m and lead upto 1.5 m complete all as specified an das directed. |
| 261 | All as per item No 2 above but exc 1.5 m but not exc 3 m deep |
| 262 | All as per item No 2 above but exc 3.00 m but not exc 4.5 m deep |
| 263 | All as per item No 2 above but exc 4.50 m but not exc 6.0 m deep |
| 264 | M&L for PCC 1:4:8 type D-2 using 40mm graded stone agg as in fdn filling, mass concrete etc complete all as specified. |
| 265 | M & L for Brick work with Sub class 'B' bricks, old size, straight or curved on plan exc 6m mean radius built in cement mortar 1:4 complete all as specified. |
| 266 | M & L for PCC 1:2:4 mix type B1 using (20mm graded stone aggregate) as in coping complete all as specified. |
| 267 | 100 mm thick PCC 1:2:4 type B 2 (40mm graded aggregate) as in sub base complete all as specified. |
| 268 | M&L for 15 mm thick cement plaster in CM 1:4 on walls surface or concrete incl finished surfaces shall be even and smooth without using extra cement complete all as specified. |
| 269 | RCC Pipe 450mm bore dia in class NP-2 laid and jointed complete with collars all as specified and directed. |
| 270 | M&L for loose filling with broken stone or boulder aggregate of gauge 80-150 mm as in filter bed complete all as specied. |
| 271 | M&L for loose filling with broken stone or boulder aggregate of gauge 40 as in filter bed complete all as specied. |
| 272 | M&L for loose filling with broken stone or boulder aggregate of gauge 20 as in filter bed complete all as specied. |
| 273 | M&L for coarse sand filling under floors or in foundations including watering and consolidation |
| 274 | Precast RCC 1:2:4 type B1 (using 20 mm graded crushed stone aggregate) as in cover slab and similar work includind necessary formwork set in cm 1:4 complete. |
| 275 | M & L for mild steel bars 10mm dia & over cut to length bent to shape required including,crancking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.90mm dia or securing with clips, quality confirming to TMT bars |
| 276 | Returning, filling in, including spreading, leveling, watering and well ramming in layers not exc. 25 cm complete all as specified. |
| 277 | Removing excavated material exc 250m but not exc 500 m and depositing where directed by Engr-in-charge at a level n.exc 1.5m above the starting point complete all as specified and directed. Total carried over to BOQ Rs. 278552.9 Signature of Contactor DY Dir(Contracts) Date: For Accepting Officer Schedule 'A' Part IX (Arboliculture ) Item Description of Item Unit Rate per Unit (Rs.) Qty Amount (Rs.) |
| 278 | Excavation in post holes (or similar holes) each n.exc. 0.50 Cum in self/loose soil getting out, returning filling in and ramming earth or broken rubble mixed with earth around in layers not exceeding 25 CM, watering and removing surplus soil, to a distance n.exc. 50 M. and making good surplus complete all as specified and directed. |
| 279 | M&L for PCC 1:4:8 type D-2 using 40mm graded stone aggregate as in foundation filling and mass concrete complete all as specified and directed. |
| 280 | S&F framed work as in door or gates of angle or other section with gusset places, rails, braces etc complete drilled for fixing of steel sheeting or other covering doors etc to be prepared for hanging or sliding with and including hooks, hinges complete all as specified and directed by Engineer-in-Charge. (for tree guard) |
| 281 | S&F Welded steel wire fabric n. exc 4kg per sqm in weight, complete to wood or steel members complete all as directed. |
| 282 | Preparation of two coats of synthetic enamel paint on new steel surfaces of any description, over 10cm in width or girth,not otherwise described including preparation over a coat of red oxide Zinc chrome prime complete all as specified and directed complete all as specified and directed. Total carried over to BOQ Rs. 338394.0 Signature of Contactor DY Dir(Contracts) Date: For Accepting Officer Schedule 'A' Part X (FIRE FIGHTING SYSTEM) Item Description of Item Unit Rate per Unit (Rs.) Qty Amount (Rs.) |
| 283 | Supply and fixing and testing of ISI Marked MS Pipe class 'B' and specials etcas per IS 1239 for fixing on walls/roofs with supports for hydrant system including transportation provision of specials like bends tees reducers flanges etc welded in proper position incl thrust blocks in PCC 1:2:4 on all bends tees and junctions etc as required wrapping and coating conformating to IS 15337-2003 etc) providing tapping for pressure gauge and other instruments making holes/chasing in walls masonary, RCC slab if required testing, flushing & cleaning of pipe line by water & l for 100MM Dia complete all as specified and directed. |
| 284 | Supply and fixing and testing of ISI Marked MS Pipe class 'B' and specials etcas per IS 1239 for fixing on walls/roofs with supports for hydrant system including transportation provision of specials like bends tees reducers flanges etc welded in proper position incl thrust blocks in PCC 1:2:4 on all bends tees and junctions etc as required wrapping and coating conformating to IS 15337-2003 etc) providing tapping for pressure gauge and other instruments making holes/chasing in walls masonary, RCC slab if required testing, flushing & cleaning of pipe line by water & for 50MM Dia complete all as specified and directed. |
| 285 | Supply and fixing and testing of ISI Marked MS Pipe class 'B' and specials etcas per IS 1239 for fixing on walls/roofs with supports for hydrant system including transportation provision of specials like bends tees reducers flanges etc welded in proper position incl thrust blocks in PCC 1:2:4 on all bends tees and junctions etc as required wrapping and coating conformating to IS 15337-2003 etc) providing tapping for pressure gauge and other instruments making holes/chasing in walls masonary, RCC slab if required testing, flushing & cleaning of pipe line by water & for 25 MM Dia complete all as specified and directed. |
| 286 | S & F Valve,gun metal gate/stop, screwed,15 mm with iron wheel head, screwed both ends for iron pipe and fixeding for 25 mm bore complete all as specified and directed. |
| 287 | S & F Valve,gun metal gate/stop, screwed,50 mm with iron wheel head, screwed both ends for iron pipe and fixeding for 50 mm bore complete all as specified and directed. |
| 288 | Supplying, fixing and testing of cast iron Sluice valve PN1.6 as per IS-14846, body, dome, wedge-CI IS:210, rings -bronze IS:318, Spindle-SS IS:6603, Gland Paking greasy jute packing, fasteners-CS, Gasket- Natural rubber, nominal size DN-100 mm,both ends flanged , complete all as specified and directed by Engr-in-charge.Note : Suitable size flanges, Joints and jointing materials shall be included under this item. |
| 289 | Supply and fixing of ISI Marked single headed 63mm dia gunmetal Landing Valve flanged inlet with 63mm female instantaneous outlet confirming to IS 5290 on the fire wet riser/down comer including making 80 NB Pipe connection with riser fixing the landing valves in proper positions including supply of nuts bolts gaskets caps chains ets testing the hydrant and completion the work in complete all as specified and directed. |
| 290 | Supply and fix Gun metal fire brigade in let connection for connecting to external fire hydrant ring main consisting of two nos 63mm dia instantaneous type male coupling with built in check valves and 150mm dia, flanged outlet complete with all accessories. complete all as specified and directed. |
| 291 | Supply and fix Valve, reflux, with by-pass Arrangement, 100mm (4”) dia per IS 5312 part I including transporting to worksite, supply & fixing nuts, bolts gaskets, flanges & washers etc including testing. Complete as per drawing & directed. |
| 292 | S & F for booster(pressure) pumps / Terrace pump for 440 V, 3 Phase, 50 Hz Confirming to IS- 12469 :1988 With CI Casing bronze impeller and stainless steel shaft mounted on heavy duty bearings suitable for 440 volts, 3 phase, 50 Hz 30m head, 900 LPM discharge including suitable size automatic pressure maintained pump starter complete all as specified and as directed. Total carried over to BOQ Rs. 455511.52 Signature of Contactor DY Dir(Contracts) Date: For Accepting Officer Schedule 'A' Part XI (Lighting Protection) Item Description of Item Unit Rate per Unit (Rs.) Qty Amount (Rs.) |
| 293 | Supply & fix aluminium strips 25x3 mm with saddles and fixing screws etc. for roof conductors and down conductors above ground complete all as directed. |
| 294 | S&F test point terminal block made out of gun metal or phosphorus bronze size 75x75x25mm drilled and screwed including 3 nos. 8mm dia 25mm long hex. head screw , drolled , cutting upper & lower portion for incoming & outgoing including double insulators two coat of synthic enamel paint complete as directed . |
| 295 | Supply and fix air termination rod single pointed aluminium rod 12 mm dia & 300 mm long complete all as directed. |
| 296 | M&L for 100 mm thick PCC 1:2:4 TYPE B1 using 20mm graded stone aggregate as in floorcomplete all as directed. |
| 297 | Supply and errect vertically Galvanised, medium grade pipe 20 mm diameter complete with fittings for raising height for air termination rods all as specified and directed complete all as directed. Total carried over to BOQ Rs. 54713.84 Signature of Contactor DY Dir(Contracts) Date: For Accepting Officer Schedule 'A' Part XII (Summer & cooling Appliances ) Item Description of Item Unit Rate per Unit (Rs.) Qty Amount (Rs.) |
| 298 | Supply and fix Water heater (Geyser), storage type, electric,capacity 25 litres.BEE 5 star rated , Heating Element: 1500 W , Pressure Rating: High-pressure rating (8 Bar), Inner Tank Material: High-grade Stainless Steel or Glass-lined coated Steel (minimum thickness 1.5 - 2.0 mm)Outer Body Material: ABS plastic (rust-proof) or CRCA Mounting: HZ OR Vertical wall mounting, Safety Features: Multi-function safety valve (safety relief valve), thermal cut-off,connection pipe, ISI marked , Warranty: Minimum 2 years on product and 5 years on inner tank including all fixing clamps, nut, bolts etc and complete all as directed. |
| 299 | Supplying, installing, balancing and commissioning of site fabricated Galvanised Sheet Steel (GSS) ducts conforming to IS: 277. The duct shall be fabricated either from , rectangular ducting complete with neoprene rubber gaskets,elbows,splitter damper vanes,hangars,supports.Duct work shall be rigid and straight without kinks.All exposed ducts within the conditioned space shall have slip joints. Flanged joints shall not be used.Ducts shall be supported independently from the building structure and adequately, to keep the ducts true to shape. The support spacing shall be not more than 2 m.Duct connections to the air-handling unit shall be made by inserting a double canvas sleeve 100 mm long The steel sheets shall be hot dip galvanized with MAT finish with coating of minimum 120 grams per square meter (GSM) of Zinc, GI sheets shall be lead free, eco friendly and RoHS compliant. All sheet metal connections, partitions and plenums required for flow of air through the filters, fans etc. shall be at least 1.25 mm thick galvanised steel sheets.Hanger rods shall be of mild steel and of at least 10 mm dia for ducts upto 2250 mm size, and 12 mm dia for larger sizes.All nuts, bolts and washers shall be zinc plated steel. All rivets shall be galvanised or shall be made of magnesium - aluminium alloy. Self tapping screws shall not be used.The fabrication of ducts shall be carried out as per approved drawings and specifications of following sheet thickness complete all as specifed and as directed.Note: (i) The duct work shall be as per IS 655.(ii) The GSS sheets for duct work shall conform to class viii with zinc coating of 120 gm/sq mtr as per ISS-277.(iii) The ducting layout will be approved by GE before execution. Supply & fix 0.63 mm thickness sheet (24 gauge) for Longest side 750mm and below sqm 1224.74 2027.2 2482792.93 Supply & fix 0.80 mm thickness sheet (22 gauge) for Longest side 751 mm to 1500 mm sqm 1632.99 206.8 337702.33 |
| 300 | S&F MS Cooler stand made of GI angle min. 45X45X5 mm including all fabrication welding work and fixing on roof and wall for mounting air cooler units incld one coat of primer and 2 coat of paint complete all as specified and directed. |
| 301 | Supply and install hi wall split units 1 TR ,indoor/outdoor complete with cordless remote control unit and with in built air ioniser and Plasma filter for better indoor air quality , minimum 5 star rating and EER 3.2 , inverter technology, R-32, R-410A, copper condensor, inclding outdoor unit stand, PVC drain pipe upto 7 mtr lengh and making all connection complete all as specified and as directed. |
| 302 | Supply and install hi wall split units 1.5 TR ,indoor/outdoor complete with cordless remote control unit and with in built air ioniser and Plasma filter for better indoor air quality , minimum 5 star rating and EER 3.2 , inverter technology, R-32, R-410A, copper condensor, inclding outdoor unit stand, PVC drain pipe upto 7 mtr lengh and making all connection complete all as specified and as directed. |
| 303 | Supply, installation, commis-sioning of Metal Top Deep Freezer, R-32/ R-410A, single phase 240 volt, 50 Hz complete all as specified and as directed. |
| 304 | Supply and fix water cooler electric driven (single phase), having approx storage capacity of 80 litre and nominal cooling capacity of 40 Litres per hour Total carried over to BOQ Rs. 4155163.77 Signature of Contactor DY Dir(Contracts) Date: For Accepting Officer Schedule 'A' Part XIII (Site Clearance) Item Description of Item Unit Rate per Unit (Rs.) Qty Amount (Rs.) |
| 305 | Suraface excavation n.exc 30 cm deep and averaging 15 cm and getting out in soft soil. |
| 306 | Excavating over areas, n exc 1.5 m deep and getting out soft/loose soil |
| 307 | Earth filling (for site development) incl raising (or lowering) not exc 1.5 m high earth spreading in layers n.exc 30 cm thick watering and rolling and finishing to reqd size and shape etc |
| 308 | Removing excavated material to a distance exc 500m but n exc 1.5km, depositing where directed at a level n exc 1.5 M above the starting point. Total carried over to BOQ Rs. 1599577.5 Signature of Contactor DY Dir(Contracts) Date: For Accepting Officer |
AI Tender Summary
Tender Timeline
Tender Published
Tender notice published.
CompletedCorrigendum-1 Issued
Clarifications on tender conditions and amendments issued.
Upcoming · 21 daysBid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 21 daysBid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 28 daysTender Documents
Download All (ZIP) ↓We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender