Educational and Research Institute Boards / Undertakings / PSU Closing in 7 days TDR #56675639

Tender For Supply Installation Testing and Commissioning of 02 Nos. Of Cooling Tower Having Capacity (90Tr X 2) By Replacing One Old Cooling Tower At Animal House Plant, Pgimer, Chandigarh.

Issued by Boards / Undertakings / PSU · Chandigarh, Chandigarh
Tender Value
17.75 Lakhs
Estimated cost
Bid Submission
05 Aug 2026
7 days left
EMD
35500
Bank guarantee accepted
Document Fee
Ref. Documents
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Chandigarh → Chandigarh
EMD Exemption
Not Available
Quantity
Not Available

Project Description

Tender for Supply Installation Testing and Commissioning of 02 Nos. Of Cooling Tower Having Capacity (90Tr X 2) By Replacing One Old Cooling Tower At Animal House Plant, Pgimer, Chandigarh.

BOQ

Name of Work:- SITC of 02 nos. of cooling tower having capacity (90TR x 2) by replacing one old cooling tower at Animal House Plant, PGIMER, Chandigarh.
Sl. No. Item Description
1Supply, Installation, testing and commissioning of Induced Draught Counter Flow type Premium low noise , CTI Certified Cooling Towers as per CTI STD-201. The Cooling Tower’s make should be listed on Cooling Technology Institute (CTI) web link. The Cooling Tower shall be complete with FRP Casing, FRP Basin, FRP louvers, FRP access door along with FRP inspection window. All internal supports/ structure should be Pultruded FRP. Unpressurised - Gravity Flow, Header and branch arm type water distribution system. 0.2 mm thick PVC Film Fills, High Efficiency Drift Eliminators, Ladder and Axial Flow Propeller Type Fan. Motor should be Totally Enclosed Air Over (TEAO), Weather Proof type with IP-55 protection class & Premium Efficiency, suitable for 415±10% volts, 50 cycles, 3 phase power supply and related accessories. Motor RPM should not be more than 360 RPM with direct driven system. FRP Deflector Cowls with acoustic enclosure to further reduction of noise is mandatory. The Cooling Tower selection should be identifiable from the selection matrix of the manufacturer at the CTI website.
290 TR Induced draft Cooling tower (HVAC Application) Water flow rate: in m3/hr. / USGPM/ LPM =280 USGPM Inlet (Hot) water Temp: in degree C / in degree F =97.5 F Outlet (Cold) water temp: in degree C / in degree F = 90F Wet bulb temp: in degree C / in degree F =83 F 2
3CONDENSER WATER PIPE
4Supplying, fixing, testing and commissioning of condenser water pipes of following sizes of MS 'C' class along with necessary clamps, vibration isolators and fittings such as bends,tees etc.butexcluding valves, strainers, gauges etc. adequately supported on rigid supports duly painted/buried in ground excavation and refilling etc. as per specification and as required complete in all respect. Note:-The Pipes size 150mm & below shall be M.S. 'C' class as per IS : 1239 and pipes size above 150mm shall be welded black steel pipe heavy class as per IS: 3589, from minimum 6.35mm thick M.S. Sheet for pipes upto 350 mm dia. And from minimum 7mm thick MS sheet for pipes of 400 mm dia and above.
5200 mm Dia
6150 mm Dia
7100 mm Dia
850 mm Dia
9BUTTERFLY VALVE (MANUAL) with C I body SS disc nitrile sheet & O - ring & PN 16 pressure rating as specified.
10200 mm dia
11150 mm dia
12100 mm dia
1350 mm dia
1440 mm dia
15Providing & fixing in position the industrial type pressure gauges with gun metal / brass valves complete as required.
16Providing & fixing in position the mercury in glass industrial type thermometers.
17Civil Part
18Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns,pillars, piers, abutments, posts and struts etc. above plinth level up to floor five level, excluding cost of centering, shuttering, finishing and reinforcement :
191:1.5:3 (1 cement : 1.5 coarse sand(zone-III) : 3 graded stone aggregate 20 mm nominal size
20Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete above plinth level.
21Thermo-Mechanically Treated bars of grade Fe-500D or more.
22Centering and shuttering including strutting, propping etc. and removal of form for :
23Foundations, footings, bases of columns, etc. for mass concrete
24Lintels, beams, plinth beams, girders, bressumers and cantilevers
25Columns, Pillars, Piers, Abutments, Posts and Struts
26Providing and fixing G.I. pipes complete with G.I. fittings including trenching and refilling etc.
2732 mm dia nominal bore
2840 mm dia nominal bore
29Applying priming coat:
30With ready mixed red oxide zinc chromate primer of approved brand and manufacture on steel galvanized iron/steel works
31Painting with synthetic enamel paint of approved brand and manufacture to give an even shade :
32Two or more coats on new work
33Electrical Work
34Supplying, installation, testing and commissioning of complete cable work using 1.1kV grade XLPE insulated PVC sheathed steel tape/wire armoured underground stranded cables as per IS-7098 (Part-1) of following sizes of electric supply from main panels in AC plant room, to various loads including interconnections (terminations) from starters to motors on suitable cable trays / existing uPVC pipe with supports as required including connections with end termination on both sides as per specifications and as required.
353 core 10 sqm mm aluminium armoured cable.
36Supplying and installing following size of perforated painted with powder coating M.S. cable trays with perforation not more than 17.5%, in convenient sections, joined with connectors, than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with M.S. suspenders including bolts & nuts, painting suspenders etc as required.
37100 mm width X 50 mm depth X 1.6 mm thickness
38Dismantling of cooling tower, pipes, valves, cable, cable tray, RCC, brick work etc, and lifting shifting of malba to nearest dumping site as required to complete satisfaction of E.I.C.
39Buy back cost of all dismantled old material like cooling tower,motors,pipes,valves, ozone injection unit, assorted filters (206 nos) etc. complete in all respect.(Excluding copper cable, cable tray and other item if any as directed by E.I.C) Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 56675639
AUTHORITY Boards / Undertakings / PSU
TENDER VALUE 17.75 Lakhs
LAST DATE 05-08-2026
Authority
Authority Name Post Graduate Institute Of Medical Education And Research
Work Description Tender for Supply Installation Testing and Commissioning of 02 Nos. Of Cooling Tower Having Capacity (90Tr X 2) By Replacing One Old Cooling Tower At Animal House Plant, Pgimer, Chandigarh.
Basic Detail
Tender No PGI/Engg/RAC/2026/318
Bidding Type Tender
Location
City Chandigarh
State Chandigarh
Key Dates
Publish Date 27 Jul 2026
Submission Date 05 Aug 2026
Open Date 06 Aug 2026
Finance
Tender Value 17.75 Lakhs
Tender Fee Ref. Documents
EMD 35500
Exemption Not Available
Document List
BOQ_966006.xls
defd9ec5-d912-4a14-8ca9-4ae14f862eaf.html
Tendernotice_1.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Jul 27, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Aug 05, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 7 days
Aug 06, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 8 days

Tender Documents

Download All (ZIP) ↓
xls

BOQ_966006.xls

html

defd9ec5-d912-4a14-8ca9-4ae14f862eaf.html

pdf

Tendernotice_1.pdf

Disclaimer