Rural Development Government Departments Closing in 12 days TDR #56674794

Tender For Construction Of New Upgraded Higher Secondary School Buildings Under Samagra Shiksha And Stars (Plus 2 Arts Stream) At Urubali Ughs Under Kalimela Block 2025-26

Issued by Government Departments · Malkangiri, Odisha
Tender Value
1.25 Crore
Estimated cost
Bid Submission
11 Aug 2026
12 days left
EMD
1.26 Lakhs
Bank guarantee accepted
Document Fee
10000
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Malkangiri → Odisha
EMD Exemption
Available
Quantity
Not Available

Project Description

Tender for Construction Of New Upgraded Higher Secondary School Buildings Under Samagra Shiksha And Stars (Plus 2 Arts Stream) At Urubali Ughs Under Kalimela Block 2025-26

BOQ

Name of Work:- Const. of New Upgraded Higher Secondary School buildings under Samagra Shiksha and Stars (Plus 2 Arts Stream) at Urubali UGHS under Kalimela Block 2025-26
Sl. No. Item Description
1Earth work in excavation and foundation of structures upto 3 mtr depth as per drawing and technical specification cluse 1104 including setting out construction of shoring and bracing removal of stumps all complete as per direction of Enginee-in-charge. GROUND FLOOR
2Supplying filling in foundation and plinth with sand including watering ramming, cost, conveyance, royalties and all taxes of materials and cost of labour with T&P required for the work etc. complete (measurement will be taken on finished section only etc.complete as directed by the Engineer-in-charge. GROUND FLOOR
3Providing and laying plain cement concrete of proportion (1:3:6) in foundation and floors using 4 cm. size black hard crusher broken granite stone metal and screened and washed sharp sand for mortar of approved quality and from approved quarry including hoisting, lowering, laying concrete, ramming, watering and curing etc. complete to required levels laid in layers not exceeding 15 cm. thick in each layer including cost, conveyance, royalties, taxes of all materials and cost of all labours, T&P etc complete as per the direction of the Engineer in charge. GROUND FLOOR
4Brick masonary in cement mortar (1:6) using Cement flyash of size 10 x 5 x 3 having crushing strength not lessthan 75 Kg/Cm2 after immersing the bricks for six hours in water before use in Foundation and plinth in all florrs with all necessary projection, cutting mlulding, corbelling, champering, watering and curing including cost conveyance, royalties and taxes of all materials and labour T&P required for the work etc.complete as per the direction of Engineer in Charge. GROUND FLOOR
5R.C.C. work with M-20 grade In Different Works having minimum compressive strength in work test of 200 Kg/Cm2 at 28 days using 20 mm and down graded size black hard crusher broken granite stone chips of approved quality and from approved quarry including hoisting lowering and laying concrete and compacting by using vibrators watering, curing for 28 days, centring & shuttering and finishing the exposed surface smooth providing grooves or beads where necessary in all floors including cost, conveyance, royalties and taxes of all materials , cost of all labour with cost of all T&P required for the work etc. complete in all respect but excluding cost and conveyance of M.S. rods or steel & binding wires and labour charges for strengthening, cutting, bending grills and placing in proper position. GROUND FLOORColumn Base
6Plinth Bend / Grade Beam GROUND FLOOR RCC M-20
7Bedblock ( Window sill ) GROUND FLOOR RCC M-20
8LINTEL BAND GROUND FLOOR RCC M-20
9Column in Super structure GROUND FLOOR RCC M-20
10ROOF BEAM GROUND FLOOR RCC M-20
11STAIR CASE GROUND FLOOR RCC M-20
12CHAJJA AND FINS
13ROOF SLAB
14Providing HYSD bar reinforcement for R.C.C. work including Straightening, cutting, bending, binding, welding, tying the grills, laying and placing in proper position as per approved design and drawing including cost, conveyance of 18 to 20 gauge binding wire cost and conveyance of HYSD bars complete in all respect as per specification for road & Bridge and direction of Eng - in Charge. GROUND FLOOR
15Brick work with Flyash Bricks 10cm x 5cm x 3cm size having crushing strength not less than 75Kg/cm2 with dimensional tolerance ±2 percent in cement mortar (1:6) in Foundation and Plinth including watering curing, cost of carriage, royalty and taxes of all materials, cost of all labour, etc complete as per the direction of E.I.C.GROUND FLOOR
1620mm thick cement plaster in C.M. ( 1:4) for Grading plaster with all cost conveyance etc. complete.
1720mm thick cement plaster (1:6)in finished smooth to outside smooth surface of stone work or Brick work in Foundation and plinth afrer racking out joints including watering and curing etc.complete with cost,conveyance royalties,all taxes and cost of all materials and cost of all labour with T&P requred for the work complete. as per the direction of Engineer in Charge.
18Providing 12 mm thick cement plaster with cement mortar of mix (1:6) with screened and washed sharp sand for mortar and finished smooth to the rough surface of walls in all heights after racking out joints including watering and curing, rounding of corners, providing grooves where ever necessary with cost, conveyance, royalties and taxes of all materials with cost of all labour, T&P, and scaffolding required for the work etc. complete in all respect as directed by the Engineer in charge. Ground Floor
19Providing 16 mm thick cement plaster with cement mortar of mix (1:6) with screened and washed sharp sand for mortar and finished smooth to the rough surface of walls in all heights after racking out joints including watering and curing, rounding of corners, providing grooves where ever necessary with cost, conveyance, royalties and taxes of all materials with cost of all labour, T&P, and scaffolding required for the work etc. complete in all respect as directed by the Engineer in charge. Ground Floor
20Supplying , fitting and fixing of 32mm thick flush door shutter with approved quality of 30mm thick BWR block board pasted with 1mm thick Sunmica on both side of approved design and quality including cost of all door with frame fitting and fixture etc complete(SR 2022 misla. item no-9/page-234)
21Supplying , fitting and fixing of two track UPVC sliding window of approved make with 6 mm thick glass of approved quality complte with frame,shutters and all fiiting and fixtures (SR-2022 Mis. item n0-13/page no-235)
22Supplying,fitting and fixing of M.S. doors, windows and iron grill gate made out of (45x45x60)mm size angular frame with square bar M.S. flat for grills of approved design icluding all cost conveyance taxes etc. complete. ( Prevaling lowest local market rate and excluding labour for fixing )
23Labour for fitting and fixing of MS Shutters for doors,window and grill gates,Collapsible gate including filling the holes with C.C (1:3:6) etc.completeGROUND FLOOR
24Fixing vetrified tiles in floors,treads and landings on 25mm thick bed of cement mortar (1:1) joined with neat cement slurry mixed with pigment to match the shade of the tiles including rubbing and polishing including cost of tile. GROUND FLOOR
25Fixing vetrified tiles in dados,skirting and in rises of steps on 12mm thick bed of cement plaster (1:3) joined with neat cement slurry mixed with pigment to match the shade of the tiles including rubbing and polishing including cost of tile.GROUND FLOOR
26Fixing chequred tiles in floors,treads and landings on 25mm thick bed of cement mortar (1:1) joined with neat cement slurry mixed with pigment to match the shade of the tiles including rubbing and polishing including cost of tile. GROUND FLOOR
27Supplying, fitting afixing of stainless steel of 304 grade in hand railing using 50mm dia of 2mm thick circular pipe with Balustrade of size 32mm x 32mm @ 0.90mtr. C/C and stainless square pipe bracing of size 32mm x 32mm x 2mm in 3 rows in stair case as per approved design and specification, buffing, polishing etc. with cost conveyance, taxes of all materials labour, T&P etc. required for the complete in all respect.
28Finishing wall surface with two coats of approved quality of weather seal coat of approved shade over a coat of primer including cost of all materials etc.complete.
29Finishing wall surface with acrylic wall putty finished smooth to exposed new plastered surface including cost of all materials etc.complete.
30Painting two coats with approved paint over a coat of primer Including cost of all materials etc. complete.
31Cement washing one coat including watering ,curing with cost,conveyance, royalities of cement etc.Complete as per direction of Engineer-in-Charge
32Distempering two coats with any approved shade including cost of distemper GROUND FLOOR
33RCC wok of M-25 grade with 20mm downgraded size hard granite chips including hoisting and laying LINTEL BEND HEAD ROOM
34RCC wok of M-25 grade with 20mm downgraded size hard granite chips including hoisting and laying Column in Super Structure HEAD ROOM
35RCC wok of M-25 grade with 20mm downgraded size hard granite chips including hoisting and laying ROOF BEAM HEAD ROOM
36RCC wok of M-25 grade with 20mm downgraded size hard granite chips including hoisting and layingCHAJJA AND FINS HEAD ROOM
37RCC wok of M-25 grade with 20mm downgraded size hard granite chips including hoisting and laying ROOF SLAB HEAD ROOM
38Supplying fitting and placing uncoated HYSD bar reinforcement complete asper drawing and technical specification. HEAD ROOM
39Brickwork with Cement Cement Flyash bricks/KB Bricks in cement mortar (1:6) in Super structure HEAD ROOM
4020mm thick cement plaster in C.M. ( 1:4) for Grading plaster with all cost conveyance etc. complete. HEAD ROOM
41Providing 12 mm thick cement plaster with cement mortar of mix (1:6) with screened and washed sharp sand for mortar and finished smooth to the rough surface of walls in all heights after racking out joints including watering and curing, rounding of corners, providing grooves where ever necessary with cost, conveyance, royalties and taxes of all materials with cost of all labour, T&P, and scaffolding required for the work etc. complete in all respect as directed by the Engineer in charge. Head room
42Providing 16 mm thick cement plaster with cement mortar of mix (1:6) with screened and washed sharp sand for mortar and finished smooth to the rough surface of walls in all heights after racking out joints including watering and curing, rounding of corners, providing grooves where ever necessary with cost, conveyance, royalties and taxes of all materials with cost of all labour, T&P, and scaffolding required for the work etc. complete in all respect as directed by the Engineer in charge. Head room
43Supplying , fitting and fixing of 32mm thick flush door shutter with approved quality of 30mm thick BWR block board pasted with 1mm thick Sunmica on both side of approved design and quality including cost of all door with frame fitting and fixture etc complete(SR 2022extra item no-9/page-234) HEAD ROOM
44Supplying,fitting and fixing of M.S. doors, windows and iron grill gate made out of (45x45x60)mm size angular frame with square bar M.S. flat for grills of approved design icluding all cost conveyance taxes etc. complete. ( Prevaling lowest local market rate and excluding labour for fixing )
45Finishing wall surface with two coats of approved quality of weather seal coat of approved shade over a coat of primer including cost of all materials etc.complete. HEAD ROOM
46Painting two coats with approved enamel paints of approved colour, shade over a coat of primer including sand papering, polishing the surface, cost, conveyances of all materials and cost of all labour etc, complete as per specification & direction of E.I.C.HEAD ROM
47Cement washing one coat including watering ,curing with cost,conveyance, royalities of cement etc.Complete as per direction of Engineer-in-Charge HEAD ROOM
48Distempering two coats with any approved shade including cost of distemper
49P.H.WORKS -Earthwork in all kinds of soil in excavation of foundation trenches within 50m initial lead and 1.5m initial lift including rough dressing and breaking clods to maximum 5cm to 7cm and laying in layers not exceeding 0.30m in depth etc all complete as per direction of the E.I.C. Initial lift upto 1.5 mtr 1 x 5.80 m x 3.20 m x 1.50 m=27.84 cum
50From 1.5 mtr to 3.0 mtr depth 1 x 5.80 m x 3.20 m x 1.50 m=27.84 cum
51Supplying all materials, labour, T&P and filling in foundation and plinth with river sand well watered and rammed including conveyance of all materials to work site, payment of royalty, taxes etc all complete as per the direction of the E.I.C.1 x 5.80 m x 3.20 m x 0.15 m=2.784 cum
52Supplying all materials, labour, T&P and providing cement concrete (1:3:6) with 40mm H.G metal including watering, curing and conveyance of all materials to site payment of royalry, taxes etc all complete as per P.H specification and direction of the E.I.C. 1 x 5.80 m x 3.20 m x 0.15 m=2.784 cum
53Supplying all materials, labour, T&P and providing plain cement concrete (1:1.5:3) with 12mm size H.G chips including watering, curing and conveyance of all materials to work site, payment of royalty, taxes etc all complete as per P.H specification and direction of the E.I.C. 1 x 5.80 m x 3.20 m x 0.10 m=1.856 cum + 1 x 4.00 m x 1.40 m x 0.038 m = 0.212 Cum
54Supplying all materials,labour, T&P and providing Brick work with K.B.Brick having crushing strength not less than 75 Kg/CM2 with dimensional tolerence of +/- 8% in C.M including watering, curring, conveyance of all materials to work site, payment of royalty, taxes etc all complete as per P.H specification and direction of the E.I.C. In Foundation and Plinth in C:M (1:4) 2 x ( 5.50 + 1.40 ) m x 0.75 m x 0.75 m = 7.762 cum + 2 x ( 5.26 + 1.40 ) m x 0.63 m x 0.75 m = 6.293 cum + 2 x ( 5.00 + 1.40 ) m x 0.50 m x 0.75 m = 4.80cum + 2 x ( 4.70 + 1.40 ) m x 0.35 m x 0.75 m = 3.202cum
55In Superstructure in C:M (1:6) 1 x 0.50 m x 0.50 m x 0.50 m = 0.125cum
56Supplying all materials, labour, T&P and providing cement plaster on brick/stone work including watering,curring and conveyance of all materials to work site, payment of royalty, taxes etc all complete as per P.H specification and direction of the E.I.C. 20 mm thick C.P in C:M (1:3) 2 x ( 4.00 + 1.40 ) m x 3.00 m =32.40sqm + 1 x 4.00 x 1.40 m = 5.60 sqm + 2 x ( 4.70 + 2.10 ) m x 0.75 m =10.20sqm + 4 x 0.50 x 0.50 m = 1.00 sqm
57Supplying all materials, labour, T&P and providing cement punning on plastered surface including watering,curring and conveyance of all materials to work site, payment of royalty, taxes etc all complete as per P.H specification and direction of the E.I.C.Same as item 20mm C.P in 1:3 =
58Supplying all materials, labour, T&P and providing rigid and smooth centering and shuttering for RCC work including false work and dismantling then after casting including conveyance of all materials to work site, payment of royalty, taxes etc all complete as per P.H specification and direction of the E.I.C. 2 x ( 4.70 + 2.10 ) m x 0.15 m = 2.04 sqm + 1 x 4.00 m x 1.40 m = 5.60 sqm
59Supplying all materials, labour, T&P and providing M.S.reinforcements for RCC work including cutting, bending, binding, straightening and tying the grills and placing in position including cost of binding wire 18 to 20 gauge conveyance of all materials to work site, payment of royalty, taxes etc all complete as per P.H specification and direction of the E.I.C.
60Supplying all materials, labour, T&P and providing reinforced cement concrete (1:1.5:3) with 12mm size H.G chips including watering, curing and conveyance of all materials to work site, payment of royalty, taxes etc all complete as per P.H specification and direction of the E.I.C. 1 x 4.70 m x 2.10 m x 0.15 m =1.48 Cum
61Supplying all materials, labour, T&P and making M.S. Step Iron in 20mm Dia M.S Steel bars and fixing into walls of Manhole/ Septic Tanks duly embeded in C.C(1:2:4) etc all complete as per P.H specification and direction of the E.I.C.
62Supplying all materials, labour, T&P and providing 50mm thick pre-cast R.C.C. baffle wall in R.C.C(1:1.5:3) including reinforcement cage using 12mm size HG chips fitted and fixed in position, finished smooth etc. complete including cutting grooves and mending good the damages etc all complete as per P.H specification and direction of the E.I.C. 2 x 1.80 m x 0.45 m
63Supplying all materials, labour, T&P and providing 160mm dia P.V.C Tee inside the septic tank including cutting holes and duly embeded in P.C.C(1:1.5:3) using 12mm size HG chips fitted and fixed in position and mending good the damages etc all complete as per P.H specification and direction of the E.I.C.
64Supplying all materials, labour,T&P and providing 12mm thick cement flush pointing in C:M (1:3) to Brick Masonry works including watering curring and conveyance of all materials to work site, payment of royalty, taxes etc all complete as per P.H specification and direction of the E.I.C. 2 x ( 5.50 + 2.90 ) m x 0.75 m = 12.60 Sqm + 2 x ( 5.26 + 2.66 ) m x 0.75 m =11.88Sqm + 2 x ( 5.00 + 2.40 ) m x 0.75 m =11.10Sqm + 2 x ( 5.50 + 2.66 ) m x 0.12 m =1.95Sqm + 2 x ( 5.26 + 2.40 ) m x 0.13 m =1.99Sqm + 2 x ( 5.00 + 2.10 ) m x 0.15 m =2.13Sqm
65Supplying all materials, labour,T&P and filling Foundation and Plinth with excavated earth including watering, ramming etc all complete as per direction of the E.I.C.
66Supplying all materials labour T&P and providing precast RCC manhole cover with cc (1:12:3) of 12mm hg chips including conveyance of all materials to site after payment of royalty and taxes etc. all complete as per PH specification and direction of EIC-(size 550mmx550mmx76mm)
67Supplying all materials, labour, T&P and constructing Manhole Chamber of the following sizes with cement concrete (1:3:6) using 40 mm size HG metal on bed, 1st class KB Brick work in CM (1:6) moulding and shaping the channel inside and benching with C:C (1:1.5:3) using 12 mm size H.G chips, 12 mm thick cement plaster (1:3) with punning to inside, cement flush pointing (1:3) to outside, RCC cover slab in C.C(1:1.5:3) using 12 mm size H.G chips with RCC man hole cover, earth work excavation in all kinds of soil and refilling the cavity around the camber including watering, curing, conveyance of all materials to worksite, payment of royalty, taxes etc. all complete as per approved specification and direction of E.I.C
68Supplying all materials labour T&P and cutting holes through brick/stone masonry works including making good the damages in cm (1:4) for taking H.C.I/PVC pipes and fittings etc. all complete as per PH specification and direction of EIC.250mm thick wall
69375mm thick wall
70Supplying all materials, labour, T&P and cutting grooves in pucca floors and walls for taking G.I./P.V.C. pipes and making good the damages as per direction of the E.I.C.
71Supplying all materials labour T&P and fitting & fixing UPVC SWR soil waste ventilating pipes and fittings of the following OD conforming to ISI No.13591/1992 to walls with nails bobbins and wooden plugs or laying in trenches including jointing with supply of approved rubber lubricant by non-heat application method as per manufacturers specification testing e. w. in excavation in all kinds of soil and refilling of trenches as per direction of EIC 110mm dia UPVC SWR Pipe with rain water piping (.Ashirvad / Supreem / Oriplast / Hariplast)110mm dia UPVC SWR Pipe
72110mm dia U-PVC S. Trap
73110mm dia U-PVC P. Trap
74110mm U-PVC S/J with Door
75110mm U-PVC door bend
76110mm dia U-PVC Plain bend
77125mm dia CP Grating
78110mm U-PVC Plain Tee
79110mm U-PVC Cowl
8075mm dia U-PVC SWR Pipe
8175mm dia U-PVC Plain Tee
8275mm U-PVC Door Bend
8375mm U-PVC Plain Bend
84Supplying all materials labour T&P and constructing gully trap chamber of the following inside size with 8cm thick RCC precast cover slab in cc (1:1.5:3) using 12mm size hg chips foundation concre3te(1:3:6) using 40mm size hg metal on bed and around trap FLY ASH Brick work in cm (1:6) in F&P and inside 12mm thick cp (1:3) finished with a floating coat of neat cement including fixing 100mm size HCI gully trap and grating etc. all complete as per approved drawing specification and dir of EIC.Inside size 250mmx250mm gully trap
85Supplying all materials, labour T&P and construction of Inspection chamber of the following sizes with c.c.(1:3:6) using 40mm size hg metal on bed, FLY ASH Brick work in cm(1:6) moulding and shaping the channel inside and benching with c.c. (1:1.5:3) with punning to inside cement flush pointing (1:3) to outside RCC cover slab in cc (1:1.5:3) using 12mm size hg chips with RCC m. h. cover, e. w. in excavation in all kinds if soil and refilling the cavity around the chamber including watering, curing, conveyance of all materials to site payment of royalty taxes etc. all complete as per approved specification and direction of EIC.Inside size : 760 x 760 x 460mm Inspection Chamber
86Supplying all materials labour T&P and construction soak way pit of the following sizes with dry brick walling from bottom upto invert of inlet pipe and FLY ASH Brick work in cm(1:6) for the remaining height at top 12mm thick cp (1:4) inside and outside over masonry brick work gravel packing the rear of well staining RCC cover slab in c.c. (1:1.5:3) using 12mm size hg chips fitted with iron lifting handles including e.w. in open well excavation in all kinds if soil and refilling the cavity around the pit and painting the iron works, watering, curing, conveyance of all materials to work site payment royalty, taxes etc. complete as per approved drawing specification and direction of EIC. 1.20m dia x 2.00m deep soak way pit
87Supplying all labour materials T&P and laying of UPVC soil waste pipe of the fo0llowing internal diameter confirming to IS in trenches of the depth upto 1.2mtr including jointing with supply of approved rubber, lubricant by non heat application method on bending with 150mm thick cc (1:3:6) using hg metal of 25mm to 40mm and then making all-round encasing including earth work excavation in all kinds of soil, refilling the trenches watering, curing, conveyance of all materials to site payment of royalty, taxes etc. & testing all complete as per PH sp and dir of EIC.110mm dia with Haunch top
88Supplying all labour materials T&P and laying of UPVC soil waste pipe of the fo0llowing internal diameter confirming to IS in trenches of the depth upto 1.2mtr including jointing with supply of approved rubber, lubricant by non heat application method on bending with 150mm thick cc (1:3:6) using hg metal of 25mm to 40mm and then making all-round encasing including earth work excavation in all kinds of soil, refilling the trenches watering, curing, conveyance of all materials to site payment of royalty, taxes etc. & testing all complete as per PH sp and dir of EIC.110mm dia with allround encasing
89160 mm dia allround
90Supplying all materials, labour, T&P and providing, laying soakway gallary with SW/PVC pipes, jointing lead loose packed allround with stone boulders 50mm to 150mm other than granite, covered at top with a layer of flat tiles 300mmx300mmx25mm including earthwork in excavation of trenches in all kinds of soil to an average depth of 1.5 mtr, covering of earth at the gallary top etc. all complete as per approved drawing and direction of the E.I.C.160 mm dia PVC gallary
91Providing and fixing Chlorinated polyvinyl Chloride (CPVC) Pipes conforming to I.S 15778 having the thermal stability for hot and cold water supply including all CPVC plain and brass threaded fittings including fixing the pipes with clamps at 1.00 mtr spacing, this includes jointing of pipes and fittings with one step solvent cement and testing of joints etc all complete as per direction of the E.I.C. 20 mm dia C-PVC Pipe( Internal)
9225mm dia C-PVC Pipe (Internal)
9332 mm dia C-PVC Pipe(External)
9440mm dia C-PVC Pipe (external)
95Supplying all materials labour T&P and fixing water storage sintex tanks including and providing extra sockets and jam nuts, fixing ball valve etc. including hoisting and placing the to the required position, including cost of tank conveyance and taxes of all materials to work site etc. all complete as per PH specification and direction of EIC. 2000 lit sintex tank (F Floor)
96Supplying all materials labour T&P and construction of masonry staging with providing 1st KB brick work in cm (1:6) of 0.40mtr height in staging and in circular protection wall to support to the tank 12mm thick cement plaster in cm (1:4) over brick work RCC beam of 2.61 x 0.25x0.30 using cc (1:1.5:3) using 12mm chips including centering and shuttering curing, conveyance of all materials to work site etc. all complete as per sp and dir of EIC.2000 ltr capacity tank F Floor
97Supplying of ISI mark 1.00 HP single phase vertical submersible pump set with discharge of 900-1000 ltr/hour and a head of 50-60 mtr of reputed make like KSB/Texmo & Equivalent including all cost, conveyance and taxes etc. all complete as per direction of E.I.C.
98Supplying all labour T&P and fitting and fixing of 1.00HP single phase verticaql submersible pump set with commissioning and testing etc. all complete as per direction of EIC.
99Supplying and fitting and fixing of ISI mark DOL starter of reputed make like BCH or equivalent for 1.00HP single phase submersible pump including all cost, conveayance and taxes etc. all complete as per direction of EIC.
100Supplying and fitting and fixing of three core flat cable (1.5mm2) of ISI make of reputed company like BCH/Finolex or equivalent and connecting the pump and starter including all cost, conveyance and taxes etc. all complete as per direction of EIC.
101Supplying and fitting and fixing jof plastic rope, MS well cover, MS clamp, stainless steel short piece, bend & socket including all cost, conveyance and taxes etc. all complete as per direction of EIC.
102Supplying and fitting and fixing of HDPE pipes and pipe fittings with making connection to pump set including all cost, conveyance and taxes etc.all complete as per direction of EIC.25mm dia HDPE Pipe(Internal Pipe)
103Labour for drilling a perfectly bore holes as specified dia for a specified defth below ground level through consolidated and unconsolidated rock with down the hole hammer drilling rig or combination rig as required to suit the site condition as per direction of engineer incharge including use of own rig with its accessories, tools and plants and consumables etc. for lowering of 200 mm dia PVC/G.I./M.S. pipes for housing fitted with socket and with or without well screen as per the necessity for soft, medium, hard and boulder formation (PVC/G.I./M.S) casing pipes if required to prevent collapse of over borden is to be provided by the contractor including lowering and withdrawing after completion of the tube well. a) Labour for Drilling i) 0.00 mtr to 91.00 mtr & above
104Lowering the following size of G.I./PVC housing pipe with or without slotted pipes as per necessity from ground level upto 30.00m depth and fitted and fixed up in perfectly vertical position including cutting and threading of pipes and slotted pipes and supplying and fixing all jointing materials, tools and plants complete and keeping the top of casing pipe threading including plugging tube well to prevent entry of foreign materials from above (G.I./PVC) supplied by the contractor (including cost of casing pipe. 2 Nos a) Lowering of 200 mm dia PVC casing pipe
105b) Cost of 125mm dia PVC casing pipe (80 Sch) i) From 0 mtr to 30.00m and above
106Cleaning and developing the tube well using their own compressor continuously worked till clean and adequate discharge as obtained from the tube well including supply of and use of all necessary equipments and labour as per the direction of engineer incharge.
107Supplying all materials, labour, T&P and constructing Protection Chamber of the following sizes with cement concrete (1:3:6) using 40 mm size HG metal on bed, 1st class KB Brick work in CM (1:6) moulding and shaping the channel inside and benching with C:C (1:1.5:3) using 12 mm size H.G chips, 12 mm thick cement plaster (1:3) with punning to inside, cement flush pointing (1:3) to outside, RCC cover slab in C.C(1:1.5:3) using 12 mm size H.G chips with RCC man hole cover, earth work excavation in all kinds of soil and refilling the cavity around the camber including watering, curing, conveyance of all materials to worksite, payment of royalty, taxes etc. all complete as per approved specification and direction of E.I.C 500 x 500 x 460 mm
108Factory made FRP(alternately called GRP) door frame of size 75mmx100mm fabricated using E-glass Chopped Strand Mat (CSM) U.V stabilised Inopthalic Gelcoat and impregnated with Inopthalic resin. The thickness of the GRP skins shall not be less than 2.00mm. The door frame consist of four segments which are provided with plug-in-socket arrangement in-situ in the mould. The segments are plugged in and are joined together by means of screw. The GRP frame shall be provided with wooden reinforcement on six locations for high screw holding capacity for for fixing metallic hold fast and shall be consolidated by filling with medium density foam/plaster of paris with fibre reinforcement, Six numbers of 260mm x 25mm x 5mm size 'S' shaped M.S flat hold fast shall be provided with the frame. The material and process for manufacturing the door frames shall conform to RV-TIFAC composites Design Centre's standards and specifications. The finish of door frame will be plain colour white/ Ivory/ Beige/ Light grey/ Golden brown/Mahogany/ Teak wood/sand stone/Champagne/Pastel blue or any other colour using high quality pigments complete in all respect as per specification and direction of the E.I.C Door -6x ( 2.10 + 2.10 + 0.75 ) =29.70
109Factory made single leaf rigid FRP(alternately called GRP) sandwich composite door shutter of 32mm thick laminated with two GRP skins with wood grain finish fabricated using UV-stabilised Isopthalic Gelcoat and one layer of 450 gsm E-glass Chopped Strand Mat (CSM) impregnated with orthopthalic palyester resin. The thickness of the skins shall not be less than 1.50mm Expanded Polystyrone(EPS) structural foam panel of 29mm thickness and a density of 20kg/cu.mtr shall be used as core material. Wooden reinforcements made of seasoned sal wood block of cross section not less than 28mmx32mm and also necessary sal wood reinforcements for fitting the metal fittings such as tower bolts, aldrops, handles etc shall be provided. A structural adhesive compatible with (EPS) foam shall be used for bending the core material, the sal wood reiforcements and the skins. The material and process for manufacturing the door shutters shall conform to RV-TIFAC composites Design Centre's standards and specifications and the door shutters tested in conformation to IS: 4020-1998. The finish of door shutter will be plain colour white/ Ivory/ Beige/Light grey/ Mahogany/Teak wood or any other colour using high quality pigments. Three heavy whight mild steel butt hinges type-I(ISI marked) size 100mm are to be fitted on one side of shutter. Door -6 x 2.05 x 0.72 =8.85
110Supplying all materials labour T&P and fixing Ceramic tiles in floors. Treads and landing on 25mm thick bed of cement mortar (1:1) joined with neat cement slurry mixed with pigments to match the3 shades of the tiles including rub bins and dir of EIC. Ground Floor
111Supplying all materials labour T&P and fixing porcelain glazed tiles/Marble tiles /Kota /Kodappa tiles in walls / dados skirting on 12mm thick cp (1:3) jointed with neat cement slurry mixed with pigments to match the shades of the tiles including rub bins and polishing complete as per direction of EIC.
112Supplying all materials, labour T&P and fixing Wash Down Water Closet(Europeon type W.C. pan) with Integral S trap to the floor with wooden plug and C.P.screws including jointing the trap with soil pipe in C.M.(1:1) etc. all complete as per specification & direction of E.I.CE..W.C. with S trap plain(Neycer/ Parry ware/ Cerra) single unit
113Providing & Fixing wall Mounted Grab Bar 600 mm long including making good the damages, including cost of all materials completed as per specification and direction of the E.I.C.
114Supplying all materials labour T&P and fixing wash basins with hole for pillar taps with CI/MS brackets painted white including holes in walls and making good the damages etc .all compt. As per PH sp. And dir. Of EIC.550x400mm WHB-( Paryware/Nycer/ cerra )
115Supplying all materials labour T&P and fixing mirror of superior glass mounted on 6mm thick AC sheet or plywood sheet and fixed to wooden plugs with cp screws and washers compt. As per PH specification and direction of EIC.B.E Mirror
116Supplying all materials labour T&P and fixing standard size cp towel rail/ring compt. with cp brass brackets fixed to wooden plugs with cp screws as per PH specification and direction of EIC.CP Towel rail (20x600) heavy Stainless steel with Ambar make .
117CP Towel ring heavy Stainless steel with mousoumi make .
118Supplying all materials labour T&P and fixing standard size cp soap holder compt. With cp brass brackets fixed to wooden plugs with cp screws as per PH specification and direction of EIC Stainless steel with heavy good quality
119Supplying all materials, labour T&P and fitting and fixing Acraylic shelf including polishing all complete as per P.H. specification and direction of EIC. 450mmx125mm size Plate Acraylic Shelf with heavy good quality
120Supplying all materials labour T&P and fitting and fixing 10 ltr capacity low level flushing cistern with a pair of cast iron or m.s. brackets complete with fittings such as siphonic arrangements 15mm nominal size brass/pvc ball valve with polythene float, c.p. brass handle, unions and couplings for connection with inlet, outlet and overflow pipes, 32mm dia cp foush bend, 15mm dia pvc inlet connection pipe including cutting holes and making good the same and connecting the flush bend with cistern and closet and connecting inlet pipe with supply main etc. all complete as per specification and direction of EIC. 10ltr Capacity Cistern ( Paryware/Nycer/ cerra )
121Supplying all materials, labour, T&P and fixing bowl pattern urinal(Hindware,Parryware,Cera) including connecting the urinal with waste pipeby means of white lead mixed with chopped hemp etc all complete as per specification and direction of the E.I.C.Half stall urinal
12215mm dia urinal Spreader
12332mm dia Dome wate
124Supplying all materials,labour, T&P and providing marble slab in urinal partition wall including cutting grooves in wall and making good the damages including watering curing etc as per specification and direction of the E.I.C 2 x 0.60m x 0.90m = 1.08 sqm
125Supplying all Materials labour T&P and fitting and fixing brass/CP Fittings ( Jaquar) of the following nominal bore with supply of all jointing materials etc. complete as per PH Specification and Direction of EIC. 15mm dia cp bib cock S.B. Jaquar
12615mm dia cp bib cock L.B. Plaza/Amber Deluxe
12715mm dia CP Two way bib Cock Plaza/Amber Deluxe
12815mm dia CP pillar cock Plaza/Amber Deluxe
12915mm dia cp concealed stop cock Plaza/Amber Deluxe
13015mm dia cp angle stop cock Plaza/Amber Deluxe
131Health Fuccet
13215mm dia CP flange
13315mm dia CP Extension piece Plaza/Amber Deluxe
13425mm dia Brass Ball Valve
13532 mm dia Brass Ball Valve
136E.I. WORKS :- Recessed wiring to light point with 1.5 sq.mm FR PVC insulatedsingle core multistrand copper conductor of ISI marked with 20 mm dia non-metalic PVC flexible conduit with 5Amp, 250 V piano type modular switch ISI marked and ceiling rose ISI marked mounted on MS box having front Modular base & cover of suitable size , MS box with 1 sq.mm FR PVC insulated single core multistrand copper conductor as earth wire including all accesories and connection as per direction of Engineer in Charge. ( Make of wire Finolex/ L&T / Anchor / Havels /HPL/ V Guard )
137Recessed wiring to light point with 1.5 sq.mm FR PVC insulatedsingle core multistrand copper conductor of ISI marked with 20 mm dia non-metalic PVC flexible conduit with 5Amp, 250 V piano type modular switch ISI marked and ceiling rose ISI marked mounted on MS box having front Modular base & cover of suitable size , MS box with 1 sq.mm FR PVC insulated single core multistrand copper conductor as earth wire including all accesories and connection as per direction of Engineer in Charge. ( Make of wire Finolex/ L&T / Anchor / Havels /HPL/ V Guard )
138Recessed wiring to light point with 1.5 sq.mm FR PVC insulatedsingle core multistrand copper conductor of ISI marked with 20 mm dia non-metalic PVC flexible conduit with 5Amp, 250 V piano type modular switch ISI marked and ceiling rose ISI marked mounted on MS box having front Modular base & cover of suitable size , MS box with 1 sq.mm FR PVC insulated single core multistrand copper conductor as earth wire including all accesories and connection as per direction of Engineer in Charge. ( Make of wire Finolex/ L&T / Anchor / Havels /HPL/ V Guard )
139Recessed wiring to Fan Point in...
140-do- Group A
141Recessed wiring to Exhaust Fan Point in -do- Group A
142S/F of Angle holder replacing Ceilling Rose
143S/F of 5A. Modular Switch & 5A. Modular Socket outlet of ISI marked on existing board (1.25.1+1.25.4)
144S/F of extension board of 6 modular Metal box with modular base & cover in recess including providing and fixing of 2 nos of 3pin 5/6amp modular socket out let & 2 nos of 5/6 amp piano type modular switch, connection, painting etc as required.
145S/F of Power point with 4 modular metal box with modular base & cover in recess including providing and fixing of 6 pin 15/16 amp. piano type Modular switch & Socket, connection, painting etc as required
146S/F of 1 no of 5 pin 15/16 amp. Socket , 1 no of switch & 1 no of 15/16A top with modular mini MCB, in 6 modular box with cover with connection, painting etc as required for Inverter connection.
147S/F of 18 SWG Modular metal box of following sizes (Nominal size) in recess with suitable size of Modular base & cover in front including cutting the wall and making good the same in case of recessed conduit as required. 2 Modular box with base & cover
1486 Modular box with base & cover
1498 Modular box with base & cover
15012 Modular box with base & cover
151Wiring for circuit / sub-main wiring along with earth wire with following sizes of PVC insulated single core multistrand copper conductor with ISI marked conforming to IS-694/1990 in 20mm dia non metalic heavy duty flexible conduit 1.6mm in recessed PVC conduit as required (Make of wire - Finolex/L&T/Anchor/Havels/V-guard) 2x1.5+1x1.5 (1.8.1)
1522x2.5+1x1.5 (1.8.2)
1532x4+1x1.5 (1.8.3)
1544x6+2x2.5(1:8:10)
155Inverter wiring (1x2.5smm) Copper wire (1.19.11A)
156S/F of B/C/D series SP MCB of 5 - 32A amp rating (As per direction of engineer in charge) 240Volt for lighting and other loads in the existing MCB Distribution board ISI marked complete with connection, testing and commissioning etc. as required single pole (SP) (2.6.1)
157S/F of C series 4 Pole MCB of 63A amp rating (As per direction of engineer in charge) 440Volt for lighting and other loads in the existing MCB Distribution board ISI marked complete with connection, testing and commissioning etc. as required without MCB box.
158Supply, Installation testing & commissioning of Main Switches (IS13940 part 3/1993) of following coopacity on existing surface/wall mounting & complete with H.R.C fuse links, inter connections earthing etc as required as per direction of Engineer Incharge (Make-Seimens/HPL/Anchor/L&T /Havels/C&S/R. K.)
159Supply & laying 6 SWG G.I. wire in recess for loop earthing as required (3.17)
160Item No.4. EARTHING-Provision of maintenance free Chemical Earthing with 250 micron non corrosive copper bonded rod (CPRI Certified) of 2.4 mtr length and minimum 17.2 mm dia with provision of 25kg x 2=50kg back filling ground resistance improvement compound with ROHS certified including supply and installation of heavy duty envionmental friendly poly plastic earth pit chamber with cover as per I.E Rules .The earthing should be minimum 1.5 mtr. away from the building and the two earthings must be 10 feet apart from each other as per I.E Rules .
161Providing & fixing plain 16/0.2mm twin twisted flexible, FR PVC insulated copper cable in polythene sleeve or conduit of suitable size on the floor/wall or side of the table/door etc as required.(1.31)
162S/F of 300 Exhaust fan with all accessoriesand connections (Make Usha-Aero Clean Plus DBB/ Polycab-Fresh on DBB/ Cropmton-Trans Air12 reversible/ Havells-Ventil Air DS(HS)/ Anchor-Anmol Delus R/ Orient-Power Flow DBB)
163S/F of 18-25 wt. LED single strip tube. Light fittingwith all accessories & connection (make Havels/HPL/Crompton/Polycab/PAC)
164S/F of 1200mm A.C. Ceiling fan (1Star) with all accessories and connections with out fan regulator (Make:Usha-Striker One/Neo/Crompton- highspeed/Havells-Samrat ES/Anchor- Turbo Speed Star/Orient-Summer Breeze Pro/ Great White-ALDOUS/Pollycab-Vital HS)
165Fixing /I.T.C. of stepped type Modular regulator (1.25a)
166S/F of 20mm dia down rod with all accessories (1.39+1.41)
167S/F of 60 wt. LED St. Light fitting with LED Electronic driver with all accessories & connection( Make- Crompton/Phillips/HPL/Polycab/Havells )
168S/F of 12w Watt LED Bulb
169Provision of 40mm dia HDPE pipe for laying & protection of cable
170Provision of Armoured cable size 3 1/2 x70sqmm (27)
171Laying of MV cable above 25sqmm to 120 sqmm in ground (5.1.2)
172Laying of MV cable above 25sqmm to 120 sqmm on surface (Horizontally)(5.5.2)
173Supply & fixing of 63A TPN Panel board 1. 63A MCCB (Make- Legrand/Seimens/L&T/C&S/) 2. 63A kitkat & bus bar3. 32A DP MCB- 4 nos 4. 63 A 4P load changeover switch (Legrand/Seimens/L&T/C&S)- 1nos 5. Digital Volt meter & Ameter three phase 6. All accesories & Connection (Rating & Danger borad) Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 56674794
AUTHORITY Government Departments
TENDER VALUE 1.25 Crore
LAST DATE 11-08-2026
Authority
Authority Name Rural Works Department
Work Description Tender for Construction Of New Upgraded Higher Secondary School Buildings Under Samagra Shiksha And Stars (Plus 2 Arts Stream) At Urubali Ughs Under Kalimela Block 2025-26
Basic Detail
Tender No CCERWCSBD-Online-28/2026-27
Bidding Type Tender
Location
City Malkangiri
State Odisha
Key Dates
Publish Date 27 Jul 2026
Submission Date 11 Aug 2026
Open Date 12 Aug 2026
Finance
Tender Value 1.25 Crore
Tender Fee 10000
EMD 1.26 Lakhs
Exemption Available
Document List
0960e420-71b0-4673-933f-bffe6697400a.html
BOQ_603195.xls
Tendernotice_1 (10).pdf
Tendernotice_2 (6).pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Jul 27, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Aug 11, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 12 days
Aug 12, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 13 days

Tender Documents

Download All (ZIP) ↓
html

0960e420-71b0-4673-933f-bffe6697400a.html

xls

BOQ_603195.xls

pdf

Tendernotice_1 (10).pdf

pdf

Tendernotice_2 (6).pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail
Loading tenders