Tender For Repair / Maintenance Of , Lt Panel, Lt Ug Cables, Acb, Mccb And Connected Items At Af Stn Darbhanga Under Ge Af Bihta.
Tender Value
20 Lakhs
Estimated cost
Bid Submission
18 Aug 2026
8 days left
EMD
40000
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Darbhanga → Bihar
EMD Exemption
Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender for Repair / Maintenance Of , Lt Panel, Lt Ug Cables, Acb, Mccb And Connected Items At Af Stn Darbhanga Under Ge Af Bihta.
BOQ
| Sl. No. | Item Description |
| 1 | Excavation in trenches n. exc 1.5 m wide for foundations, laying cables/ pipes etc. not exceeding 1.5 m deep and getting out in SOFT/LOOSE soil complete, all as specified. |
| 2 | Excavation in trenches n. exc 1.5 m wide for foundations, laying cables/ pipes etc. exceeding 1.5 m deep but not exceeding 3.00 m deep and getting out in SOFT/LOOSE soil complete, all as specified. |
| 3 | Returning filling in including spreading, levelling, watering and well ramming in layers not exceeding 25cm thick complete, all as specified. |
| 4 | Removal of excavated surplus spoil to a distance n. exc. 50m and depositing where directed at level not exceeding 1.5 m above the starting point complete all as specified. |
| 5 | NOTES APPLICABLE TO SERIAL ITEM 1 TO 4: (a) Excavation work shall be carried out manually only.(b) LT/HT cable, /telephone lines, if any, get damaged during excavation & earthwork, demolition of PCC shall be repaired by the contractor immediately as per existing specifications to the entire satisfaction of Engineer-in-Charge. |
| 6 | PCC type B-2 (1:2:4), using 40 mm graded stone aggregates as in filling & mass concrete, including necessary form work with fair finished surfaces of concrete complete all as specified. |
| 7 | PCC (1:3:6) type C-1 using 20mm graded stone aggregate as coping of poles etc. with slightly rounded or chamfered angles including necessary form work with fair finished surfaces of concrete complete all as specified. |
| 8 | PCC (1:4:8) type D-2 using 20mm graded stone aggregate as coping of poles etc. with slightly rounded or chamfered angles including necessary form work with fair finished surfaces of concrete complete all as specified. |
| 9 | Brick protection with old size sub class 'B' bricks laid flat across the route of underground cable all as specified. |
| 10 | Clean dry sand ( locally available) as cushioning for under ground cable 230 mm thick (one layer of 80 mm thickness before laying the cable and other layer of 150 mm thickness after laying the cable) complete all as specified.NOTE:- Punned down thickness (over all 180 mm) shall be considered for measurement and payment. |
| 11 | GI pipe light grade with all fittings fixed as termination postal ,fixed to poles/ walls/ protection of cable under floors/ under road etc complete all as specified of following size: - |
| 12 | 40 mm bore |
| 13 | 80 mm bore |
| 14 | 100 mm bore |
| 15 | Supply, laying, jointing & testing of LT XLPE insulated cable screened, bedded, galvanised steel strip or wire armourd cable (heavy duty) 1100 volt grade with aluminium conductor conforming to IS-7098 (Part-I -1988) laid in trenches/ ducts/ through pipes/ in floors / under roads/ hard standing /along poles and testing including takind down existing cable complete all as specified of sectional area: - |
| 16 | 10 Sq.mm,4 core |
| 17 | 16 Sq.mm,4core |
| 18 | 25 Sq.mm,3.5 core |
| 19 | 35 Sq.mm,3.5 core |
| 20 | 50 Sq.mm,3.5 core |
| 21 | 70 Sq.mm,3.5 core |
| 22 | 95 Sq.mm,3.5 core |
| 23 | 120 Sq.mm,3.5 core |
| 24 | 185 Sq.mm,3.5 core |
| 25 | 240 Sq.mm,3.5 core |
| 26 | 300 Sq.mm,3.5 core |
| 27 | Cable joining kit (straight through epoxy joint) for 1100 V (Earthed) grade cable complete with jointing material and accessories suitable for XPLE armoured aluminium conductor cable including taking down unserviceable termination complete all as specified of following size: - |
| 28 | 25-50 Sq. mm, 3.5 to 4 core |
| 29 | 70-95 Sq. mm, 3.5 core |
| 30 | 120-150 Sq. mm, 3.5 core |
| 31 | 185-300 Sq. mm, 3.5 core |
| 32 | Cable jointing kit for 11 KV (Earthed) grade cable for out door termination heat shrinkable type joint complete with jointing material and accessories suitable for 3.5 core 70 to 120 sqmm XLPE armoured aluminium conductor cable including taking down unsreviceable termination complete all as specified and directed |
| 33 | PVC insulated unsheathed / sheathed cable with standard aluminium conductor 1100 Volts grade flat twin core service cable of size 10 sqmm confirming to IS:694/1990 with latest amendement ISI including disconnecting / taking out existing unsv/damaged old service cable completed all as specified and directed. |
| 34 | LED street light 90 watt outdoor type pressure die cast aluminium housing, heat resistant toughtened glass with frame and lamp with minimum efficiency 110 LM/W, IP 66 protection IN REPLACEMENT and making connections, completed all as specified and directed. . |
| 35 | LED street light 120 watt outdoor type pressure die cast aluminium housing, heat resistant toughtened glass with frame and lamp with minimum efficiency 110 LM/W, IP 66 protection IN REPLACEMENT and making connections, completed all as specified and directed. |
| 36 | LED driver 90-120 watt suitable for existing LED lights completed all as specified and directed , IN REPLACEMENT, complete |
| 37 | MCCB with adjustable thermal magnetic release, ICS=ICU=100%, 3 Pole, 415 volts, AC, with over load and short circuit protection, rupturing capacity 16 kA. and rupturing capacity, IN REPLACEMENT, complete all as specified of following size:-Make : L&K/ Legrand/ABB |
| 38 | 100 Amp |
| 39 | 125 Amp |
| 40 | MCCB with adjustable thermal magnetic release, ICS=ICU=100%, 4 Pole, 415 volts, AC, with over load and short circuit protection, rupturing capacity 36 kA. and rupturing capacity, IN REPLACEMENT, complete all as specified of following size:-Make : L&K/ Legrand/ABB |
| 41 | 100 Amp |
| 42 | 125 Amp |
| 43 | 160 Amp |
| 44 | 200 Amp |
| 45 | 250 Amp |
| 46 | 400 Amp |
| 47 | MCB suitable for 240 volt AC supply, SP with over load and short circuit protection and rupturing capacity not less than 10 kA, 'C' curve type of rating 6 to 32 Amp, IN REPLACEMENT, complete all as specified. |
| 48 | MCB suitable for 240 volt AC supply, SPN with over load and short circuit protection and rupturing capacity not less than 10 kA, 'C' curve type of rating 32 Amp, IN REPLACEMENT, complete all as specified. |
| 49 | MCB suitable for 415 volt AC supply, TPN with over load and short circuit protection and rupturing capacity not less than 10 kA, 'C' curve type of rating 40 32 Amp, IN REPLACEMENT, complete all as specified. |
| 50 | MCB suitable for 415 volt AC supply, TPN with over load and short circuit protection and rupturing capacity not less than 10 kA, 'C' curve type of rating 63 Amp, IN REPLACEMENT, complete all as specified. |
| 51 | Cutting and trimming trees branch any girth and any size touching to overhead lines and cleaning the distance 2.0 mtrs length both sids of OH line with a span of 50 mtrs (approx) each disposing the same clearing the site upto the satisfaction level and all as directed by Engr-in-charge.Note : All tools, plants and machinary equipment and manning required are quoted in the rates. |
| 52 | Dismantaling of old cracked/ unserviceable PCC poles or MS pole struts any type and size incl deposited at a suitable locations not more than 50 running meter away complete all as specified and as directed by Engr-in-charge. |
| 53 | Steel tubular 9 metre long swaged pole type 410 SP-31 complete with cast iron base plate of size 300mm x 300mm x 6mm, final taper plug, bolts, nuts & screws and painting the pole with two coats of aluminum paint over a coat of primer including black and yellow strips 30cm each upto 1.5 metre from top of PCC foundation block and numbering of poles in 80mm high white letter using synthetic enamel paint over base etc including taking down old existing pole complete all as specified.Note - Excavation, earth work, PCC in foundation and coping shall be measured and paid seperately under relevant item of this schedule. |
| 54 | External electric complaints by opening / disconnecting the electrical connection of defective / burnt out underground LT cable of any size & any core from main switch / DB / junction box / LT panel / L T O/H line etc. and taking out the required length of cable from existing loop and remove/ cut the defective cable,replace the same with new cable as per existing size including providing necessary thimbles / connectors at cable end and reconnecting the cable in previous location with existing main switch / DB / Junction box / LT panel / OH line etc. and make electic connection as functionable in all repspects including testing on completion all as specified and directed by Engineer-in-charge. |
| 55 | Note:- (a) The rate quoted shall deemed to be inclusive of the following: (i) Necessary earth work excavation in any type of soil, returning, filling and removing extra soil. (ii) Existing bricks, sand,GI protection pipe etc. shall be removed carefully and stacks neatly near site and same shall be re- laid after attending fault/defect. (iii) Distrubed surface of road, floor etc. shall be make good to match with existing surface. (iv) Minimum two numbers of electrician and two numbers of helpers shall be deployed for attending complaints regulerly on daily basis and contractor shall collect the complaints details from complaint cell of AGE E/M No.2 and same shall be rectified/ attanded within an hour and report shall be submitted to Engineer-in-charge or their authorised representative. (b) Please note that payment shall be made to contractor one time only for this items. if any fault/ default occured again on the same location/ DB/junction box/panel during currency of contract, the same shall be rectified by the contractor without any extra cost to Govt. in terms of condition 46 of IAFW of genral condition of contracts. (c) Additional bricks,sand,GI pipe etc. as required for cable protection and cushioning shall be measured and paid separetely under relevent item. |
| 56 | Dismantling / disconnecting / removing the faulty / burnt out overhead conductor of any type / size from insulator of HT / LT pole any type by making proper shutdown from department and removing of tree / branches if any fell on Over Head Line, loose the binding wire in each insulators and disconnecting cable connection as required, remove the burnt / damage conductor / earth wire and making necessary joint with new ACSR conductor of suitable size as per existing as directed, restretching all the loose spans of ACSR conductors, earth wire etc. with insulator and providing binding wire of existing size to tigheting and making LT/HT cable in existing position and make electric connection as functionable in all respects including testing on completion allas specified and directed by Engineer in charge. |
| 57 | NOTE: The rate quoted shall deemed to be inclusive of the following:- (i) Tools and plants such as ladder,rope, cutter, axes, knife etc. as required for cutting and removing tree/branches if any fall on OH line. (ii) Insulator,binding wire etc. as required in addition to existing shall be provided by the contractor. (iii) Minimum two numbers of electrician and two numbers of helpers shall be deployed for attending complaint regularly on daily basis and contractor shall collect the complaint details from complaint cell of AGE E/M No. 2 (iv) Additional ACSR conductor and earth wire shall be measured and paid separetely under relevant items. Please Enable Macros to View BoQ information |
| 58 | NOTE: The rate quoted shall deemed to be inclusive of the following:- (i) Tools and plants such as ladder,rope, cutter, axes, knife etc. as required for cutting and removing tree/branches if any fall on OH line. (ii) Insulator,binding wire etc. as required in addition to existing shall be provided by the contractor. (iii) Minimum two numbers of electrician and two numbers of helpers shall be deployed for attending complaint regularly on daily basis and contractor shall collect the complaint details from complaint cell of AGE E/M No. 2 (iv) Additional ACSR conductor and earth wire shall be measured and paid separetely under relevant items. Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Jul 27, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedAug 18, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 8 daysAug 24, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 14 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender