Drinking Water Supply and Sanitation Government Departments Closing in 7 days TDR #56674639

Tender For Construction And Commissioning Of Bore Hole By Dth/Rotary/ Combination Rig Of 200 Mm Dia, Supply And Installation Of Energy Efficient Submersible Pump Sets, Panels, Cables And Other Allied Works Including Commissioning And Testing Of Tube

Issued by Government Departments · Jaipur, Rajasthan
Tender Value
2.40 Crore
Estimated cost
Bid Submission
04 Aug 2026
7 days left
EMD
4.80 Lakhs
Bank guarantee accepted
Document Fee
10000
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Jaipur → Rajasthan
EMD Exemption
Available
Quantity
Not Available

Project Description

Tender for Construction And Commissioning Of Bore Hole By Dth/Rotary/ Combination Rig Of 200 Mm Dia, Supply And Installation Of Energy Efficient Submersible Pump Sets, Panels, Cables And Other Allied Works Including Commissioning And Testing Of Tube Well Under Jurisdiction Of Phed Division Jobner With 24 Months Defect Liability With 5 Years Operation And Maintenance (Arc).(Estimated Cost 240.00 Lac)

BOQ

Name of Work:- Construction and Commissioning of bore hole by DTH/Rotary/ Combination rig of 200 mm dia, supply and installation of energy efficient Submersible Pump sets, Panels, Cables and other allied works including commissioning and testing of tube well under Jurisdiction of PHED Division Jobner with 24 months defect liability with 5 years operation and maintenance (ARC).(Estimated Cost 240.00 Lac)
Sl. No. Item Description
1Construction of tube well from ground level & up to 100 mtr depth to accommodate housing and assembly pipe of following sizes in all type of alluvium strata unconsolidated formation such as pebbles, boulders etc. by percussion/rotary drilling method as per IS:2800 Part 1: 1991 and IS:2800 Part II: 1979 (both amended up to date) and technical specifications, with gravel as per IS:4097-1967 and it's packing as per IS: 2800 (Part I & II) 1979 as amended up to date (the work includes the cost of gravel & it's primary packing and packing during development, lowering of housing & strainer assembly pipes with supply and wrapping of coir-rope, wherever necessary for arresting fine sand particles and development work, but excluding the cost of housing and strainer pipe assembly). The work would be completed after obtaining sand free water.Rates are exclusive of GST.
2Nominal bore 200 mm dia.
3Add 15% extra on above item (Item no 2.1.1 to 2.1.3) for drilling depth beyond 100 mtr and up to 200 mtr, rate shall be applicable for only extra depth beyond 100 mtr and up to 200 mtr.Rates are exclusive of GST.
4Add 40% extra on above item (Item no 2.1.1 to 2.1.3) for drilling depth beyond 200 mtr, rate shall be applicable for only extra depth beyond 200 mtr .Rates are exclusive of GST.
5Construction of Tube Well from ground level and up to 100 mtr. depth to accommodate housing and assembly pipe in all type of alluvium strata, unconsolidated formation such as pebbles, boulders etc. by percussion/ rotary drilling method as per IS:2800 Part 1: 1991 and IS:2800 Part II: 1979 (both amended up to date) and technical specifications for removal of overburden. The work includes the cost of lowering of casing pipe, but excludes the cost of casing pipe. Rates are exclusive of GST.
6Nominal bore 200 mm dia.
7Add 15% extra on above item (Item No 2.2.1 to 2.2.2) for drilling depth beyond 100 mtr, rate shall be applicable for only extra depth beyond 100 mtr .Rates are exclusive of GST.
8Construction of tube well after completion of drilling by rotary /percussion method & up to 100 mtr. depth in all type of rocks by DTH system as per IS:2800 Part 1: 1991 and IS:2800 Part II: 1979 (both amended up to date) and technical specifications. The work shall be deemed completed only after obtaining sand free water. The bore well should have a throughout nominal size bore beyond casing pipe. Rates are exclusive of GST.
9Nominal bore 200 mm dia.
10Add 15% extra on above item (Item No 2.3.1 to 2.3.3) for drilling depth beyond 100 mtr and up to 200 mtr from ground level, rate shall be applicable for only extra depth beyond 100 mtr and up to 200 mtr.Rates are exclusive of GST.
11Add 30% extra on above item (Item No 2.3.1 to 2.3.3) for drilling depth beyond 200 mtr and from ground level, rate shall be applicable for only extra depth beyond 200 mtr .Rates are exclusive of GST.
12Add 15% extra on above item (Item No 2.3.1 to 2.3.3) for drilling, where strata is collapsible and lowering of casing pipe is required . The work includes lowering of casing pipe, but excluding the cost of casing pipe. The rate shall be applicable for stretch of collapsible strata only.Rates are exclusive of GST.
13Construction of Tube Well up to 100 mtr. depth in all type of rocks by DTH system & over burden to accommodate casing pipe of following sizes in all types of soils & over burden including lowering of casing pipes, (if required) excluding cost of casing pipes, as per IS:2800 Part 1: 1991 and IS:2800 Part II: 1979 (both amended up to date) and technical specifications. The work would be completed after obtaining sand free water. The tube well should have a through out bore as per nominal dia of casing pipe.Rates are exclusive of GST.
14Nominal bore 200 mm dia.
15Add 15% extra on above item (Item No 2.4.1 to 2.4.2) for drilling depth beyond 100 mtr and up to 200 mtr from ground level, rate shall be applicable for only extra depth beyond 100 mtr and up to 200 mtr.Rates are exclusive of GST.
16Add 30% extra on above item (Item No 2.4.1 to 2.4.2) for drilling depth beyond 200 mtr and from ground level, rate shall be applicable for only extra depth beyond 200 mtr .Rates are exclusive of GST.
17Add 15% extra on above item (Item No 2.4.1 to 2.4.4) for drilling, where strata is collapsible and lowering of casing pipe is required . The work includes lowering of casing pipe, but excluding the cost of casing pipe. The rate shall be applicable for stretch of collapsible strata only.Rates are exclusive of GST.
18Construction of tube well from ground level and up to 100 mtr. depth and above of following sizes in all types of soils in alluvium strata, unconsolidated formation such as pebbles, boulders etc. by \\"bailing\\" method and without gravel packing as per IS:2800 Part 1: 1991 and IS:2800 Part II: 1979 (both amended up to date) and technical specifications. The work includes formation of cavity at bottom by development with appropriate air compressor or bailer pumping and also lowering of casing pipe but excluding cost of the casing pipe. The tube well should have a throughout bore as per nominal dia of casing pipe. The work would be completed after obtaining sand free water.Rates are exclusive of GST.
19Nominal bore 200 mm dia.
20Construction of tube well from ground level and up to 100 mtr depth and above to accommodate housing assembly pipe in all type of unconsolidated formation such as pebbles, boulders, collapsible formation etc. by Odex drilling method as per IS: IS:2800 Part 1: 1991 and IS:2800 Part II: 1979 (both amended up to date) and technical specifications. The work will include lowering of housing and strainer pipe assembly and casing shoe including cost of casing shoe, but excluding cost of the casing pipe. The work would be completed after obtaining sand free water. Rates are exclusive of GST.
21Nominal bore 200 mm dia.
22Add 15% extra on above item (Item No 2.6.1 to 2.6.3) for drilling depth beyond 100 mtr, rate shall be applicable for only extra depth beyond 100 mtr .Rates are exclusive of GST.
23Deepening of existing tube well by DTH system beyond existing depth up to 100 mtr. and above in all type of rocks including flushing of tube well and obtaining sand free water. Rates are exclusive of GST.
24Nominal bore 200 mm dia.
25Testing verticality of tube well by plumbing system and yield test and draw down test by pumping system as per IS : 2800 (Part – II) – 1979 or as per amended up to date.Rates are exclusive of GST.
26Supplying & Packing P-gravel suitable for slot size/mesh size as suggested in IS 2800 (Part-1) 1991 or as per amended up to date.Rates are exclusive of GST.
27Development of tube well having depth up to 250 mtr as per IS: 11189- 1985 and IS: 2800 (Part- I)- 1991 (both amended up to date) using suitable methods to give sand free water for required yield of the gravel packed tube well.Rates are exclusive of GST.
28Supply of ERW M.S. black casing pipe ISI marked (IS: 4270/2001) or amended up to date of following sizes Rates are exclusive of GST.
29200 mm dia NB (Thickness of pipe 5.4mm & mass of tube 28.46 Kg/m)
30Labour charges for making slots on blank pipes made of ERW MS black pipe ISI marked of following sizes, the slotting should be as per IS:8110-1985. Rates are exclusive of GST.
31200 mm dia nominal bore of 5.4mm thickness
32Providing & laying ISI marked GI Pipe Light duty ( “A” class) as per IS: 1239 for casing pipe for submersible cable external work 40 mm dia complete in all respect.Rates are exclusive of GST.
33Supply & Installation of 3 phase ISI marked submersible motor pump set of three star or better rating of BEE and as per IS: 8034-2018 (pump) and IS 9283-2013 (motor) or as amended up to date of approved make of following duty condition with required accessories including making connection suitable for tube well/DCB. The job includes lowering of motor pump, installation of complete fitting & accessories, jointing of electrical cables up to switch board, testing of submersible pump set and interconnection up to water mains, complete in all respect.Rates are exclusive of GST.
34Up to 5.5 KW (7.5 HP) & head up to 120 mtr.
35Up to 5.5 KW (7.5 HP) & head above 120 mtr.
367.5 KW (10 HP) & head up to 120 mtr.
377.5 KW (10 HP) & head above 120 mtr.
389.3 KW (12.5 HP) & head up to 120 mtr.
399.3 KW (12.5 HP) & head above 120 mtr.
4011 KW (15 HP) & head up to 120 mtr.
4111 KW (15 HP) & head above 120 mtr.
4213 KW (17.5 HP) & head up to 120 mtr.
4313 KW (17.5 HP) & head above 120 mtr.
4415 KW (20 HP) and above, head up to 120 mtr.
4515 KW (20 HP) and above, head above 120 mtr.
46Supply and Fixing of electric control feeder panel comprising of suitable rating MCCB , fully automatic star-delta starter, over load relay, ampere meter with CTs, volt meter, phase preventer, suitable starting capacitors, phase indicators, lighting arrangement etc. complete suitable for three phase pump set. The panel should have space for energy meter ( supplied by DISCOM). All these equipments shall be housed by panel box made out from 18 gauge M.S. Sheet with powder coating. Panel should be of minimum size 900 x 600 x 450 mm with Stand ( made of angle iron of size 35x35x5mm) duly bolted/screwed with enclosure box having 4 legs, each leg’s length 18\\" and double door including in built locking system. The legs should be embedded in M-15 cement concrete plat form. The size of CC platform should be equal or bigger than the base size of panel having height of at least 200 mm from ground level. The panel should have opening of suitable size in front of space for energy meter with glass for meter reading. The operation of panel should be suitable for on 440 Volt AC Supply.Rates are exclusive of GST.
47Above 5 HP and up to 10 HP
48Above 10 HP and up to 15 HP
49Above 15 HP and up to 20 HP
50Above 20 HP and up to 30 HP
51Supply & Fixing of ISI marked three core PVC flat submersible cable as per IS 694:1990 or amended up to date and conductor as per class 5 of IS 8130:1980 including making connection etc. Rates are exclusive of GST.
523 core 4.0 Sq.mm
533 core 6.0 Sq.mm
543 core 10.0 Sq.mm
553 core 16.0 Sq.mm
56Supply & Fixing XLPE insulated / P.V.C. sheathed cable of 1.1 KV grade with aluminium conductor Armoured of IS:7098-I/1554-1 approved make in ground as per IS:1255 including excavation of 30cmx75cm size trench, 25 cm thick under layer of sand, second Class bricks covering, refilling earth, compaction of earth, making necessary connection, testing etc. as required of size. Rates are exclusive of GST.
5710.0 Sq.mm, 4 core
5816.0 Sq.mm, 4 core
5925.0 Sq.mm, 3.5 core
60Plate Earthing as per IS:3043 with G.I. Earth plate of size 600mm x 600mm x 6.0mm by embodying 3 to 4 mtr. below the ground level with 20 mm dia. G.I. 'B' class watering Pipe including all accessories like nut, bolts, reducer ,nipple, wire meshed funnel, and C.C. finished chamber covered with hinged type with locking arrangement C.I. Cover, C.I. Frame of size 300mm x 300mm complete with alternate layers of salt and coke/charcoal, testing of earth resistance as required. Rates are exclusive of GST.
61Supply & Fixing M S clamp set of 50x6 mm flat from iron with nuts and bolts etc. for holding the riser pipe assembly of submersible pump set.Rates are exclusive of GST.
62Supply & Fixing tube well cover of MS sheet 8mm thick at top & 5mm thick 100mm wide shroud around the edge so as to form a cap on the top end of casing pipe with GI Nipple 45cm long & two GI flanges at both ends in 80mm sizes passing through a hole in the centre of MS sheet. A 25 mm socket with end plug shall also be welded over top plate. A GI nipple having outside thread of size 1/2\\" (for installation pressure gauge) shall be provided & welded with 80mm GI nipple near top plate nipple shall be provided with end plug.Rates are exclusive of GST.
63200 mm dia
64Providing & Lowering in tube well ISI marked GI Pipe medium duty (“B\\" class), Steel tube as per IS:1239 or amended up to date and zinc coating as per IS 4736, threaded and double flanged (welded) on both ends and two number 25x3mm MS flat welded on both ends between pipe & flange, rubber washer & nut bolts etc. complete in all respect.Rates are exclusive of GST.
6532 mm dia
6650 mm dia
6765 mm dia
6880mm dia
69Providing & Lowering in tube well ISI marked HDPE pipe as per IS 4984:1995 or amended up to date in PE 80 grade and class PN 10 of following dia. including HDPE/GI fittings and PVC rope confirming to IS 5175:1992 or amended up to date, along with clamping of submersible cable etc. complete in all respect.Rates are exclusive of GST.
7040 mm dia
7150 mm dia
7263 mm dia
7375 mm dia
7490 mm dia
75Providing, installing, testing and commissioning of double flanged bulk flow meter with removable mechanism, of class B conforming to ISO 4064/1 or amended up to date of approved make including cost of all material and labour as per specifications with GI Box (sheet 16 SWG) suitable with locking arrangement of following dia.Rates are exclusive of GST.
7650 mm dia
7765 mm dia
7880 mm dia
79Providing & Fixing pump safety cage as per specifications or as directed by Engineer in charge.Rates are exclusive of GST.
80Providing & Fixing of double flanged, CI body, ISI marked NRV of approved make of following sizesRates are exclusive of GST.
8165 mm dia
8280 mm dia
83Proving and Fixing 32 mm dia Full way valve or wheel valve as per IS:778 or amended up to date of approved make, on pump delivery pipe.Rates are exclusive of GST.
84Supplying & Installing 100 mm diameter sealed diaphragm bourdon type pressure gauge of range 0 to 10 kg. including all jointing material as per specification with safety cover.Rates are exclusive of GST.
85SITC of Digital Type Single Phase DOL Starter Electrical Control Feeder Panel, 63A, suitable for operation of Single-phase pump set on 215V AC supply, comprising input MCB (DP 63A.), GFU with auxiliary contact for earth fault protection, AC-3 duty PMC based DC contactors 50 Amp. 1P (DOL type), Microprocessor basedDigital Motor Protection Unit with necessary protections, RTC timer, MCBs for power and control circuits, LED indications, Heavy duty terminal, connectors, complete internal wiring with copper conductors (for control and power), capacitor bank and all necessary hardware.The panel shall be housed in outdoor type fabricated GI enclosure of 1.6 mm thickness, Complete with all standard protections, indications and automation features required for safe, efficient and reliable operation of pump sets under varying field conditions, complete in all respects as per specification and direction of Engineer-in-Charge.
86Upto 5 HP (Single Phase)
87SITC of Digital Type DOL Starter Electrical Control Feeder Panel, 40A, suitable for operation of 3-phase pump set on 415V AC supply, comprising input MCB (40Amp. FP), GFU with auxiliary contact for earth fault protection, 32Amp. AC-3 duty PMC based DC contactors (for DOL and APSC type),Microprocessorbased Digital Motor Protection Unit with necessary protections, RTC timer, MCBs for power and control circuits, LED indications,Heavy Duty terminal, connectors, complete internal wiring with copper conductors (for control and power), capacitor bank of 3 kVAR, and all necessary hardware.The panel shall be housed in outdoor type fabricated GI enclosure of 1.6 mm thickness, Complete with all standard protections, indications and automation features required for safe, efficient and reliable operation of pump sets under varying field conditions, complete in all respects as per specification and directionof Engineer-in-Charge.
88Up to 5 HP (DOL type)
89SITC of Digital Type Star Delta Starter Electrical Control Feeder Panel, 100A, suitable for operation of 3-phase pump set on 415V AC supply, comprising input 100Amp. MCCB (TP), GFU with auxiliary contact for earth fault protection, 32Amp. AC-3 duty PMC based DC contactors (For Star and Main), 40Amp. 1 Pole Contactor for APSC, 22Amp. Contactor for Delta,Microprocessor based Digital Motor Protection Unit with necessary protections, RTC timer, MCBs for power and control circuits, LED indications, Heavy duty terminal connectors, complete internal wiring with copper conductors (for control and power), capacitor bank of 3 kVAR, and all necessary hardware.The panel shall be housed in outdoor type fabricated GIenclosure of 1.6 mm thickness, Complete with all standard protections, indications and automation features required for safe, efficient and reliable operation of pump sets under varying field conditions, complete in all respects as per specification and direction of Engineer-in-Charge.
90Above 5 HP and up to 10 HP (Star Delta type)
91SITC of Digital Type Star Delta Starter Electrical Control Feeder Panel, 100A, suitable for operation of 3-phase pump set on 415V AC supply, comprising input 100Amp. MCCB (TP), GFU with auxiliary contact for earth fault protection, 35Amp. AC-3 duty PMC based DC contactors (For Star and Main), 45Amp. 1 Pole Contactor for APSC, 25Amp. Contactor for Delta,Microprocessor based Digital Motor Protection Unit with necessary protections, RTC timer, MCBs for power and control circuits, LED indications, Heavy duty terminal connectors, complete internal wiring with copper conductors (for control and power), capacitor bank of 5 kVAR, and all necessary hardware.The panel shall be housed in outdoor type fabricated GIenclosure of 1.6 mm thickness, Complete with all standard protections, indications and automation features required for safe, efficient and reliable operation of pump sets under varying field conditions, complete in all respects as per specification and direction of Engineer-in-Charge.
92Above 10 HP and up to 15 HP (Star Delta type)
93SITC of Digital Type Star Delta Starter Electrical Control Feeder Panel, 100A, suitable for operation of 3-phase pump set on 415V AC supply, comprising input 100Amp. MCCB (TP), GFU with auxiliary contact for earth fault protection, 40Amp. AC-3 duty PMC based DC contactors (For Star and Main), 45Amp. 1 Pole Contactor for APSC, 32Amp. Contactor for Delta,Microprocessor based Digital Motor Protection Unit with necessary protections, RTC timer, MCBs for power and control circuits, LED indications, Heavy duty terminal connectors, complete internal wiring with copper conductors (for control and power), capacitor bank of 7 kVAR, and all necessary hardware.The panel shall be housed in outdoor type fabricated GIenclosure of 1.6 mm thickness, Complete with all standard protections, indications and automation features required for safe efficient and reliable operation of pump sets under varying field conditions, complete in all respects as per specification and direction of Engineer-in-Charge.
94Above 15 HP and up to 20 HP (Star Delta type)
95SITC of Digital Type Star Delta Starter Electrical Control Feeder Panel, 125A, suitable for operation of 3-phase pump set on 415V AC supply, comprising input 125Amp. MCCB (TP), GFU with auxiliary contact for earth fault protection, 45 Amp. AC-3 duty PMC based DC contactors (For Star and Main), 50 Amp. 1 Pole Contactor for APSC, 40 Amp. Contactor for Delta,Microprocessor based Digital Motor Protection Unit with necessary protections, RTC timer, MCBs for power and control circuits, LED indications, Heavy duty terminal connectors, complete internal wiring with copper conductors (for control and power), capacitor bank of 8.3 kVAR, and all necessary hardware.The panel shall be housed in outdoor type fabricated GI enclosure of 1.6 mm thickness, Complete with all standard protections, indications and automation features required for safe, efficient and reliable operation of pump sets under varying field conditions, complete in all respects as per specification and directionof Engineer-in-Charge.
96Above 20 HP and up to 25 HP (Star Delta type)
97SITC of Digital Type Star Delta Starter Electrical Control Feeder Panel, 125A, suitable for operation of 3-phase pump set on 415V AC supply, comprising input 125Amp. MCCB (TP), GFU with auxiliary contact for earth fault protection, 63 Amp. AC-3 duty PMC based DC contactors (For Star and Main), 80 Amp. 1 Pole Contactor for APSC, 50 Amp. Contactor for Delta,Microprocessor based Digital Motor Protection Unit with necessary protections, RTC timer, MCBs for power and control circuits, LED indications, Heavy duty terminal connectors, complete internal wiring with copper conductors (for control and power), capacitor bank of 12.5 kVAR, and all necessary hardware.The panel shall be housed in outdoor type fabricated GIenclosure of 1.6 mm thickness, Complete with all standard protections, indications and automation features required for safe, efficient and reliable operation of pump sets under varying field conditions, complete in all respects as per specification and direction of Engineer-in-Charge.
98Above 25 HP and up to 30 HP (Star Delta type) Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 56674639
AUTHORITY Government Departments
TENDER VALUE 2.40 Crore
LAST DATE 04-08-2026
Authority
Authority Name Public Health Engineering Department
Work Description Tender for Construction And Commissioning Of Bore Hole By Dth/Rotary/ Combination Rig Of 200 Mm Dia, Supply And Installation Of Energy Efficient Submersible Pump Sets, Panels, Cables And Other Allied Works Including Commissioning And Testing Of Tube Well Under Jurisdiction Of Phed Division Jobner With 24 Months Defect Liability With 5 Years Operation And Maintenance (Arc).(Estimated Cost 240.00 Lac)
Basic Detail
Tender No NIT 08-15/26-27 SE PHED CIRCLE JPR
Bidding Type Tender
Location
City Jaipur
State Rajasthan
Key Dates
Publish Date 27 Jul 2026
Submission Date 04 Aug 2026
Open Date 05 Aug 2026
Finance
Tender Value 2.40 Crore
Tender Fee 10000
EMD 4.80 Lakhs
Exemption Available
Document List
09TD200TWJobner.pdf
3619f18b-73e6-4ec6-a54b-fc19600237d5.html
BOQ_1026871.xls
Tendernotice_1.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Jul 27, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Aug 04, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 7 days
Aug 05, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 8 days

Tender Documents

Download All (ZIP) ↓
pdf

09TD200TWJobner.pdf

html

3619f18b-73e6-4ec6-a54b-fc19600237d5.html

xls

BOQ_1026871.xls

pdf

Tendernotice_1.pdf

Disclaimer