Drinking Water Supply and Sanitation Government Departments Closing in 8 days TDR #56672615

Tender For Construction & Commissioning Of 200Mm Dia Three Phase Tube Well On Annual Rate Contract Basis In Sandy Strata With 05 Year O&M Including Defect Liability Period Of Two Years In Urban/Rural Area Of District Bharatpur. (Nit No. 25/2026-27, E

Issued by Government Departments · Bharatpur, Rajasthan
Tender Value
1.50 Crore
Estimated cost
Bid Submission
06 Aug 2026
8 days left
EMD
3 Lakhs
Bank guarantee accepted
Document Fee
2000
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Bharatpur → Rajasthan
EMD Exemption
Available
Quantity
Not Available

Project Description

Tender for Construction & Commissioning Of 200Mm Dia Three Phase Tube Well On Annual Rate Contract Basis In Sandy Strata With 05 Year O&M Including Defect Liability Period Of Two Years In Urban/Rural Area Of District Bharatpur. (Nit No. 25/2026-27, Ec 150.00 Lacs)

BOQ

Name of Work:- Construction & Commissioning of 200mm dia three phase Tube Well on Annual Rate Contract basis in Sandy strata with 05 Year O&M including defect liability period of two years in urban/rural area of District Bharatpur. (Nit No. 25/2026-27, EC 150.00 Lacs)
Sl. No. Item Description
1Construction of tube well from ground level & up to 100 mtr depth to accommodate housing and assembly pipe of following sizes in all type of alluvium strata unconsolidated formation such as pebbles, boulders etc. by percussion/rotary drilling method as per IS:2800 Part 1: 1991 and IS:2800 Part II: 1979 (both amended up to date) and technical specifications, with gravel as per IS:4097-1967 and it's packing as per IS: 2800 (Part I & II) 1979 as amended up to date (the work includes the cost of gravel & it's primary packing and packing during development, lowering of housing & strainer assembly pipes with supply and wrapping of coir-rope, wherever necessary for arresting fine sand particles and development work, but excluding the cost of housing and strainer pipe assembly). The work would be completed after obtaining sand free water.
2Nominal bore 200 mm dia.
3Add 15% extra on above item (Item no 2.1.1 to 2.1.3) for drilling depth beyond 100 mtr and up to 200 mtr, rate shall be applicable for only extra depth beyond 100 mtr and up to 200 mtr.
4Add 40% extra on above item (Item no 2.1.1 to 2.1.3) for drilling depth beyond 200 mtr, rate shall be applicable for only extra depth beyond 200 mtr .
5Development of tube well having depth up to 250 mtr as per IS: 11189- 1985 and IS: 2800 (Part- I)- 1991 (both amended up to date) using suitable methods to give sand free water for required yield of the gravel packed tube well.
6Supply of ISI mark AC pressure pipe class 15 manufactured by MAZZA process as per IS:1592-2003 or amended up to date, for casing of tube well for following dia nominal bore, with jointing material PVC coupler as per technicalspecification and direction of Engineer In charge.
7200 mm nominal dia
8Making slots of hole size and Nos. as directed by EIC in AC pressure pipe Class 15 as per technical specification for using slotted pipe in TW casing.
9Labour charges for making slots on blank pipes made of ERW MS black pipe ISI marked of following sizes, the slotting should be as per IS:8110-1985.200 mm dia nominal bore of 5.4mm thickness
10Testing verticality of tube well by plumbing system and yield test and draw down test by pumping system as per IS : 2800 (Part – II) – 1979 or as peramended up to date.
11Supplying & Packing P-gravel suitable for slot size/mesh size as suggested in IS 2800 (Part-1) 1991 or as per amended up to date.
12Providing & laying ISI marked GI Pipe Light duty ( “A” class) as per IS: 1239 for casing pipe for submersible cable external work 40 mm dia complete in all respect.
13Supply & Installation of 3 phase ISI marked submersible motor pump set of three star or better rating of BEE and as per IS: 8034-2018 (pump) and IS 9283- 2013 (motor) or as amended up to date of approved make of following duty condition with required accessories including making connection suitable for tube well/DCB. The job includes lowering of motor pump, installation of complete fitting & accessories, jointing of electrical cables up to switch board, testing of submersible pump set and interconnection up to water mains, complete in all respect.Up to 5.5 KW (7.5 HP) & head up to 120 mtr.
14Up to 5.5 KW (7.5 HP) & head above 120 mtr.
157.5 KW (10 HP) & head up to 120 mtr.
167.5 KW (10 HP) & head above 120 mtr.
179.3 KW (12.5 HP) & head up to 120 mtr.
189.3 KW (12.5 HP) & head above 120 mtr.
1911 KW (15 HP) & head up to 120 mtr.
2011 KW (15 HP) & head above 120 mtr.
2113 KW (17.5 HP) & head up to 120 mtr.
2213 KW (17.5 HP) & head above 120 mtr.
2315 KW (20 HP) and above, head up to 120 mtr.
2415 KW (20 HP) and above, head above 120 mtr.
25Supply and Fixing of electric control feeder panel comprising of suitable rating MCCB , fully automatic star-delta starter, over load relay, ampere meter with CTs, volt meter, phase preventer, suitable starting capacitors, phase indicators, lighting arrangement etc. complete suitable for three phase pump set. The panel should have space for energy meter ( supplied by DISCOM). All these equipments shall be housed by panel box made out from 18 gauge M.S. Sheet with powder coating. Panel should be of minimum size 900 x 600 x 450 mm with Stand ( made of angle iron of size 35x35x5mm) duly bolted/screwed with enclosure box having 4 legs, each leg’s length 18\\" and double door including in built locking system. The legs should be embedded in M-15 cement concrete plat form. The size of CC platform should be equal or bigger than the base size of panel having height of at least 200 mm from ground level. The panel should have opening of suitable size in front of space for energy meter with glass for meter reading. The operation of panel should be suitable for on 440 Volt AC Supply.Above 5 HP and up to 10 HP
26Above 10 HP and up to 15 HP
27Above 15 HP and up to 20 HP
28Above 20 HP and up to 30 HP
29SITC of Digital Type Star Delta Starter Electrical Control Feeder Panel, 100A, suitable for operation of 3-phase pump set on 415V AC supply, comprising input 100Amp. MCCB (TP), GFU with auxiliary contact for earth fault protection, 32Amp. AC-3 duty PMC based DC contactors (For Star and Main), 40Amp. 1 Pole Contactor for APSC, 22Amp. Contactor for Delta,Microprocessor based Digital Motor Protection Unit with necessary protections, RTC timer, MCBs for power and control circuits, LED indications, Heavy duty terminal connectors, complete internal wiring with copper conductors (for control and power), capacitor bank of 3 kVAR, and all necessary hardware.The panel shall be housed in outdoor type fabricated GI enclosure of 1.6 mm thickness, Complete with all standard protections,indications and automation features
30Above 5 HP and up to 10 HP (Star Delta type)
31SITC of Digital Type Star Delta Starter Electrical Control Feeder Panel, 100A, suitable for operation of 3-phase pump set on 415V AC supply, comprising input 100Amp. MCCB (TP), GFU with auxiliary contact for earth fault protection, 35Amp. AC-3 duty PMC based DC contactors (For Star and Main), 45Amp. 1 Pole Contactor for APSC, 25Amp. Contactor for Delta, Microprocessor based Digital Motor Protection Unit with necessary protections, RTC timer, MCBs for power and control circuits, LED indications, Heavy duty terminal connectors, complete internal wiring with copper conductors (for control and power), capacitor bank of 5 kVAR, and all necessary hardware. The panel shall be housed in outdoor type fabricated GI enclosure of 1.6 mm thickness, complete with all standard protections, indications and automation features
32Above 10 HP and up to 15 HP (Star Delta type)
33SITC of Digital Type Star Delta Starter Electrical Control Feeder Panel, 100A, suitable for operation of 3-phase pump set on 415V AC supply, comprising input 100Amp. MCCB (TP), GFU with auxiliary contact for earth fault protection, 40Amp. AC-3 duty PMC based DC contactors (For Star and Main), 45Amp. 1 Pole Contactor for APSC, 32Amp. Contactor for Delta, Microprocessor based Digital Motor Protection Unit with necessary protections, RTC timer, MCBs for power and control circuits, LED indications, Heavy duty terminal connectors, complete internal wiring with copper conductors (for control and power), capacitor bank of 7 kVAR, and all necessary hardware. The panel shall be housed in outdoor type fabricated GI enclosure of 1.6 mm thickness, complete with all standard protections, indications and automation features
34Above 15 HP and up to 20 HP (Star Delta type)
35SITC of Digital Type Star Delta Starter Electrical Control Feeder Panel, 125A, suitable for operation of 3-phase pump set on 415V AC supply, comprising input 125Amp. MCCB (TP), GFU with auxiliary contact for earth fault protection, 45 Amp. AC-3 duty PMC based DC contactors (For Star and Main), 50 Amp. 1 Pole Contactor for APSC, 40 Amp. Contactor for Delta, Microprocessor based Digital Motor Protection Unit with necessary protections, RTC timer, MCBs for power and control circuits, LED indications, Heavy duty terminal connectors, complete internal wiring with copper conductors (for control and power), capacitor bank of 8.3 kVAR, and all necessary hardware. The panel shall be housed in outdoor type fabricated GI enclosure of 1.6 mm thickness, complete with all standard protections, indications and automation features
36Above 20 HP and up to 25 HP (Star Delta
37SITC of Digital Type Star Delta Starter Electrical Control Feeder Panel, 125A, suitable for operation of 3-phase pump set on 415V AC supply, comprising input 125Amp. MCCB (TP), GFU with auxiliary contact for earth fault protection, 63 Amp. AC-3 duty PMC based DC contactors (For Star and Main), 80 Amp. 1 Pole Contactor for APSC, 50 Amp. Contactor for Delta, Microprocessor based Digital Motor Protection Unit with necessary protections, RTC timer, MCBs for power and control circuits, LED indications, Heavy duty terminal connectors, complete internal wiring with copper conductors (for control and power), capacitor bank of 12.5 kVAR, and all necessary hardware. The panel shall be housed in outdoor type fabricated GI enclosure of 1.6 mm thickness, complete with all standard protections, indications and automation features
38Above 25 HP and up to 30 HP (Star Delta type)
39Supply & Fixing of ISI marked three core PVC flat submersible cable as per IS 694:1990 or amended up to date and conductor as per class 5 of IS 8130:1980 including making connection etc. 3 core 4.0 sq mm
403 core 6.0 Sq.mm
41Supply & Fixing XLPE insulated / P.V.C. sheathed cable of 1.1 KV grade with aluminium conductor Armoured of IS:7098-I/1554-1 approved make in ground as per IS:1255 including excavation of 30cmx75cm size trench, 25 cm thick under layer of sand, second Class bricks covering, refilling earth, compaction of earth, making necessary connection, testing etc. as required of size. 10.0 Sq mm 4 core
4216.0 Sq.mm, 4 core
4325.0 Sq.mm, 3.5 core
4435.0 Sq.mm, 3.5 core
45Plate Earthing as per IS:3043 with G.I. Earth plate of size 600mm x 600mm x 6.0mm by embodying 3 to 4 mtr. below the ground level with 20 mm dia. G.I. 'B' class watering Pipe including all accessories like nut, bolts, reducer ,nipple, wire meshed funnel, and C.C. finished chamber covered with hinged type with locking arrangement C.I. Cover, C.I. Frame of size 300mm x 300mm complete with alternate layers of salt and coke/charcoal, testing of earth resistance as required.
46Supply & Fixing tube well cover of MS sheet 8mm thick at top & 5mm thick 100mm wide shroud around the edge so as to form a cap on the top end of casing pipe with GI Nipple 45cm long & two GI flanges at both ends in 80mm sizes passing through a hole in the centre of MS sheet. A 25 mm socket with end plug shall also be welded over top plate. A GI nipple having outside thread of size 1/2\\" (for installation pressure gauge) shall be provided & welded with 80mm GI nipple near top plate nipple shall be provided with end plug. 200 mm dia
47Providing & Lowering in tube well ISI marked GI Pipe medium duty (“B\\" class), Steel tube as per IS:1239 or amended up to date and zinc coating as per IS 4736, threaded and double flanged (welded) on both ends and two number 25x3mm MS flat welded on both ends between pipe & flange, rubber washer &nut bolts etc. complete in all respect. 50 mm dia
4865 mm dia
4980 mm dia
50Providing & Lowering in tube well ISI marked HDPE pipe as per IS 4984:1995 or amended up to date in PE 80 grade and class PN 10 of following dia. including HDPE/GI fittings and PVC rope confirming to IS 5175:1992 or amended up to date, along with clamping of submersible cable etc. complete in all respect.
5175 mm dia
5290 mm dia
53Providing, installing, testing and commissioning of double flanged bulk flow meter with removable mechanism, of class B conforming to ISO 4064/1 or amended up to date of approved make including cost of all material and labour as per specifications with GI Box (sheet 16 SWG) suitable with lockingarrangement of following dia. 50 mm dia
5465 mm dia
5580 mm dia
56Providing & Fixing pump safety cage as per specifications or as directed byEngineer in charge.
57Providing & Fixing of double flanged, CI body, ISI marked NRV of approvedmake of following sizes 65 mm dia
5880 mm dia
59Providing, lowering, aligning, fixing in position in pipe line, CI D/F Sluice valves straight and pocket less body passage of approved make of following Pressure rating & dia complete, confirming to IS:14846 (amended up to date) and of following specifications: Body, Bonnet, Wedge, Gland, Thrust Plate, Cap & Hand wheel of Grey cast iron of IS:210/ FG200 Stem - AISI- 410 ,Body Seat ring, Wedge facing ring & Bushes - LTB2/ SS , Face to face dimensions as per IS 14846/2000 (amended up to date) ,Epoxy ( Non-Toxic- suitable for drinking water) applied inside and outside, Flanges Drilled as per IS 1538. Nut-Bolt confirming to IS:1363 and IS: 1367/ CS/ galvanised steel Insertion rubber of black EPDM 6mm thick . Sluice valves including all jointing & jointing material, labour, testing and commissioning along with pipe line as per Technical Specifications and as per direction of Engineer-in-charge.Note: Rates are exclusive of tail piece/ dismantling joints and earth work.Manually Operated CI Sluice valve of Class PN-1.0
6080 mm HW
61100 mm HW
62Supplying & Installing 100 mm diameter sealed diaphragm bourdon type pressure gauge of range 0 to 10 kg. including all jointing material as perspecification with safety cover.
63Maintenance of tubewells which includes round the clock monitoring of tubewells of all sizes, complete repairs / rewinding of submersible pump sets including cost of material components required to repair pumpsets, starters, meters etc. of electric panel of tube wells, lowering and unlowering of pumpsets complete in all respect, maintenance of log-books &History sheet as directed by Engineer-In-Charge for Tubewell per month. (for Rural scheme whir three phase Ele. supply is up to 8 hr.) Complete O&M rate in exclusive of GST)
640.5 HP to 5.0 HP
656.0 HP to 7.5 HP
668.0 HP to 10.0 HP
6711.0 HP to 12.5 HP
6813.0 HP to 15.0 HP
6916.0 HP to 25.0 HP
7026.0 HP to 45.0 HP
71Maintenance of tubewells which includes round the clock monitoring of tubewells of all sizes, complete repairs / rewinding of submersible pump sets including cost of material components required to repair pumpsets, starters, meters etc. of electric panel of tube wells, lowering and unlowering of pumpsets complete in all respect, maintenance of log-books &History sheet as directed by Engineer-In-Charge for Tubewell per month. for Urban Water Supply Scheme Complete O&M rate in exclusive of GST)
720.5 HP to 5.0 HP
736.0 HP to 7.5 HP
748.0 HP to 10.0 HP
7511.0 HP to 12.5 HP
7613.0 HP to 15.0 HP
7716.0 HP to 25.0 HP
7826.0 HP to 45.0 HP Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 56672615
AUTHORITY Government Departments
TENDER VALUE 1.50 Crore
LAST DATE 06-08-2026
Authority
Authority Name Public Health Engineering Department
Work Description Tender for Construction & Commissioning Of 200Mm Dia Three Phase Tube Well On Annual Rate Contract Basis In Sandy Strata With 05 Year O&M Including Defect Liability Period Of Two Years In Urban/Rural Area Of District Bharatpur. (Nit No. 25/2026-27, Ec 150.00 Lacs)
Basic Detail
Tender No Nit No. 25/2026-27
Bidding Type Tender
Location
City Bharatpur
State Rajasthan
Key Dates
Publish Date 27 Jul 2026
Submission Date 06 Aug 2026
Open Date 07 Aug 2026
Finance
Tender Value 1.50 Crore
Tender Fee 2000
EMD 3 Lakhs
Exemption Available
Document List
79457f19-c03c-4197-9c0d-3caef6dcd92a.html
BOQ_1026932.xls
td25.pdf
Tendernotice_1.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Jul 27, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Aug 06, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 8 days
Aug 07, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 9 days

Tender Documents

Download All (ZIP) ↓
html

79457f19-c03c-4197-9c0d-3caef6dcd92a.html

xls

BOQ_1026932.xls

pdf

td25.pdf

pdf

Tendernotice_1.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail
Loading tenders