Tender For Supplying, Installation And Relocation Of Electrical Panel Of Room No. 130 (Balcony) And Main Dining Hall (Cooking Area) At Vh-1.
Tender Value
6.43 Lakhs
Estimated cost
Bid Submission
03 Aug 2026
6 days left
EMD
12876
Bank guarantee accepted
Document Fee
Ref. Documents
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Kanpur Nagar → Uttar Pradesh
EMD Exemption
Not Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender for Supplying, Installation And Relocation Of Electrical Panel Of Room No. 130 (Balcony) And Main Dining Hall (Cooking Area) At Vh-1.
BOQ
| Sl. No. | Item Description |
| 1 | Supplying & drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel / PVC conduit as reqd. |
| 2 | 6 x 6 Sq.mm.. |
| 3 | 3 x 10 Sq.mm.. |
| 4 | 6 x 10 Sq.mm.. |
| 5 | S & F metal box of following sizes ( nominal size ) on surface or recess with suitable size of 3 mm phenolic laminated sheet cover in the front I/c painting etc as reqd. |
| 6 | 200 mm x 150 mm x 60 mm deep |
| 7 | Providing and fixing following rating and breaking capacity and pole MCCB with thermomagnetic release and terminal spreaders in existing cubicle panel board including drilling holes in cubicle panel, making connections, etc. as required. |
| 8 | 250 Amp. 35/36KA,TP MCCB |
| 9 | Supplying and installing following size of perforated pre-painted M.S. cable trays with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with M.S. suspenders including bolts & nuts, painting suspenders etc as required. |
| 10 | 100 mm width X 50 mm depth X 1.6 mm thickness |
| 11 | Earthing with G.I. earth pipe 4.5 Meter long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal/ coke and salt as required. |
| 12 | Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required. |
| 13 | Providing and fixing 25 mm x 5 mm GI strip in 40 mm dia GI pipe from earth electrode including connection with GI nut , bolt,spring washer excavation and refilling etc. as reqd. |
| 14 | Providing and fixing 6 SWG dia. GI wire on surface or in recess for loop earthing as reqd. |
| 15 | Laying of one no. PVC insulated, PVC sheathed / XLPE power cable of 1.1kV grade of size above 95 sqmm and upto 185 sqmm. |
| 16 | Direct in ground I/c excavation, sand cushioning, protective covering and refilling the trench etc. as reqd. |
| 17 | In pipe |
| 18 | In open duct |
| 19 | On surface with MS clamp (clamped with 25/40X3 mm MS flat clamp ) |
| 20 | Supplying and making end termination with brass compression gland, aluminium lugs for following size of PVC insulated & PVC sheathed / XLPE aluminium cable of 1.1kV grade as reqd. |
| 21 | 2 x 6 sq.mm. |
| 22 | 2 x 10 sq.mm. |
| 23 | 3.5 x 120 sq.mm. |
| 24 | Supplying and fixing of following ways surface/ recess mounting, vertical type, 415 volts, VTPN distribution board of sheet steel, dust protected, duly powder painted, inclusive of 250 amps tinned copper bus bar, with 2 neutral link, 2 earth bar, din bar and cable ties for cable management with provision for 250 Amp MCCB as incomer and SP/TP MCB's as outgoing (but without MCCB and MCB's ) as required . |
| 25 | 8 way 250 Amp MCCB DB, IP 54 |
| 26 | SITC of outdoor type feeder piller having following specifications |
| 27 | Incoming:100 A, TPN MCCB, 36 kA Thermal release type with rotatory handle with R, Y, B phase indicator with Digital Ammeter & Voltmeter with associated CT - 1 set. Outgoing 1: 5 HP Starter, 3 Phase with R, Y, B and On/off indication Lamp with Overload Relay, single Phase preventer and Phase reversal protection, with MCCB, No NC switch, contactor etc. complete as per requirement -1 Set. |
| 28 | Outgoing 2: 3 HP starter, 3 Phase with R, Y, B and On/Off indication Lamp with overload relay, single phase preventer and phase reversal protection with MCB, NO NC switch, contactor etc. complete as per requirement -1 Set. Outgoing 3: 3 HP starter, 3 phase with R,Y,B and On/off indication Lamp with overlaod relay, single phase preventer and phase reversal protection, with MCB, No NC switch, contactor etc. complete as per requirement - 1 set. Outgoing 4 : 63 Amp TPN MCB - 1 Nos. Outgoing 5 : 63 Amp TPN MCB - 1 Nos. Outgoing 6 : 63 Amp TPN MCB - 1 Nos. Outgoing 7 : 63 Amp TPN MCB - 1 Nos. Bus Bar: 250 Amp Al busbar protection of O/c S/c protection, CT short Link, Netutral Link 16 /32 etc. Panel will be double Door type with stand complete, powder coated, dust proof vermin, proof type complete as required. |
| 29 | Supply and fixing of 32 x 20 mm DLP mini- trunking white-system with independent cover etc. as required complete. |
| 30 | Supply and fixing of following accessories suitable for 32 mm x 20 mm size plastic trunking white system. |
| 31 | End cap |
| 32 | Internal / external angle |
| 33 | Changeable flat angle |
| 34 | Flat junction |
| 35 | Supply of one number PVC insulated & PVC sheathed/XLPE aluminium conductor steel armoured power cable of following sizes 1.1kV grade as per IS 7098 (part 1) 1988 of approved make. |
| 36 | 3.5 x 120 sq.mm. |
| 37 | Supply, fixing, testing & commissioning MCB of following pole and rating 240/415 volts 'C' curve 10kA in the existing MCB DB complete as reqd. |
| 38 | Triple Pole 40 amp to 63 amp |
| 39 | Supply & Laying of 32 mm dia, 8Kg / cm², minimum 2.0 mm thick HDPE pipe, ISI mark in following manners as required complete. |
| 40 | In ground i/c excavation sand cushioning protective covering, refilling of earth as reqd. |
| 41 | Laying charges In Pipe |
| 42 | Laying charges On Surface |
| 43 | Laying charges in open duct |
| 44 | Lifting & removing cable of size upto 120 sqmm from trench/ clamps on surface, making roll depositing the same in the store I/c cartage etc as reqd. |
| 45 | Dismantling of old/damaged 3 -phase electrical Panel including dismantling of MCCB/MCB/Cable/Busbar and submitting the same in store etc as reqd |
| 46 | Earth work in excavation by mechanical means (Hydraulic excavator)/ manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead upto 50 m and lift upto 1.5 m, as directed by Engineer-in charge. All kinds of soil cum |
| 47 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : |
| 48 | 1:3:6 (1 Cement : 3 coarse sand (zone-III) derived from natural sources : 6 graded stone aggregate 20 mm nominal size derived from natural sources) |
| 49 | Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor level in all shapes and sizes in : |
| 50 | Cement mortar 1:6 (1 cement : 6 coarse sand). Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Jul 25, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedAug 03, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 6 daysAug 04, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 7 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender