Tender For Construction Of Concrete Road To Dapur Dhanur Kapdane Dhamane Nagaon Road Mdr-59 Km.3/500 To 4/00 Tal.Dist.Dhule
Tender Value
3.12 Crore
Estimated cost
Bid Submission
03 Aug 2026
7 days left
EMD
1.57 Lakhs
Bank guarantee accepted
Document Fee
2360
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Dhule → Maharashtra
EMD Exemption
Not Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender for Construction Of Concrete Road To Dapur Dhanur Kapdane Dhamane Nagaon Road Mdr-59 Km.3/500 To 4/00 Tal.Dist.Dhule
BOQ
| Sl. No. | Item Description |
| 1 | Excavation for catch / side water gutter in all sorts of soils to the specified section including stacking the excavated stuff in a regular bund and disposing of unsuitable or excess stuff as directed all sorts of soils. |
| 2 | Excavation for catch / side water gutter in Hard murum and boulder strata to the specified section including stacking the excavated stuff in a regular bund and disposing of unsuitable or excess stuff as directed. |
| 3 | Excavation for roadway in earth, soil of all sorts, sand, gravel or soft murum including dressing section to the required grade, camber and side slopes and conveying the excavated materials with all lifts upto a lead of 50 metre and spreading for embankment or stacking as directed. |
| 4 | Construction of granular sub-base by providing close graded Material, mixing in a mechanical mix plant at Optimum Moisture Content, carriage of mixed Material to work site, spreading in uniform layers with motor grader/ Paver on prepared surface and compacting with vibratory roller to achieve the desired density, complete as per clause 401 -- Plant Mix Method and Grading - I Material |
| 5 | Construction of dry lean cement concrete Sub-base over a prepared sub-grade with coarse and fine aggregate (natural sand/ Verticle Shaft Impactor grade finely washed crushed sand) conforming to Indian Standards: 383, the size of coarse aggregate not exceeding 25 milimetre, cement content not to be less than 150 kilogramme per cubic metre, optimum moisture content to be determined during trial length construction, concrete strength not to be less than 10 Mpa at 7 days, mixed in a batching plant/ Weigh batch mixer, transported to site with all leads and lifts, laid with a paver with electronic sensor /by suitable means as approved by Engineer-in-charge , compacting with vibratory roller, finishing, curing and including preparation of sub-grade surface if required etcetra complete. with fully automatic micro processor based Programmable logic controller with Supervisory Control and Data Acquisition enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etcetra complete. |
| 6 | Providing and laying 125 micron Low Density Polyethylene (LDPE) sheet confirming to Indian Standards 3395 : 1997 below concrete pavement including all materials and labour complete. |
| 7 | Providing and laying in-situ Mix-40 Grade unreinforced plain cement concrete pavement over a prepared sub base with 43 grade cement, coarse and fine aggregate (natural sand/ Verticle Shaft Impactor grade finely washed crushed sand) conforming to Indian Standards 383, using fine and coarse aggregates combined gradation as per Table 600-3 of MORTH Specification 2013, mixed in a batching and mixing plant/ non tilting mixer and Weigh batcher as per approved mix design, admixtures, transporting to site, spreading, laying with approved make paver,compacted and finished in a continuous operation, finishing to lines and grades as directed by Engineer-in-charge and curing by curing compound /by providing cement vata in cement Mortar 1:8 @ 0.6 metre X 0.6 metre centre to centre, admeasuring 80 milimetre at bottom and 40 milimetre at top with depth of 75 milimetre and maintaining the same throughout curing period by any other method approved by Engineer-in-charge. with fully automatic micro processor based Programmable logic controller with Supervisory Control and Data Acquisition enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etcetra complete. |
| 8 | Providing and fixing in position Thermo Mechanical Treated FE 500, 25 milimetre dia dowel bars precoated with anticorrosive epoxy paint of required diametre 60 centimetres Long and at 30.00 centimetre Centre to Centre and wherever directed including handling, straightening, necessary cutting supported by Thermo Mechanical Treated FE 500, chairs with proper alignment by using properly designed assembly of Bulkheads lubricating half length with bituminous paint as directed Etcetera complete. |
| 9 | Providing and fixing in position Thermo Mechanical Treated FE 500, tie bars precoated with anticorrosive epoxy paint of 12 milimetre diametre 70 centimetres long and at 30.00 centimetre Center to Center and wherever directed including handling, straightening wrapping with paper of approved quality for half length, necessary cutting, handling, straightening, supported by assembly of Thermo Mechanical Treated FE 500, chairs with proper alignment Etcetera complete. |
| 10 | Cutting transverse contraction joints 3 to 4 milimetre wide and depth 60 milimetre in concrete slab using concrete cutting machine with diamond studded saw within 48 hours of casting of bay / slab Etcetera complete including subsequent widening of the groove 8 to 10 milimetre wide at top having depth of 15 milimetre as directed by Engineer incharge. |
| 11 | Providing to contraction joints polysuphide sealent (Pouring grade) confirming to BS : 5212 - 1989 into sawed groove widened at top for sealent reservoir of specified size and shape as per detailed drawing including fixing Polyethylene foam backer rod of required diameter (appraox. 25% larger than the initial 3 milimetre to 4 milimetre joint) overlaid with bond breaking tape as per detailed drawing. Item includes cleaning the joints with water jet / air compressor and allowing joint to become thoroughly dry before sealent Indian Standards applied and applying primer. (A) Contraction and longitudinal joints (15 milimetre deep x 8 milimetre wide) |
| 12 | Providing and laying Cast in situ/Ready Mix cement concrete in Mix-10 of trap/ granite/ quartzite/ gneiss metal for foundation and bedding including bailing out water, Steel centering, formwork, laying/pumping, compacting, roughening them if special finish Indian Standards to be provided, finishing if required and curing complete, with fully automatic micro processor based Programmable logic controller with Supervisory Control and Data Acquisition enabled reversible Drum Type mixer/concrete Batch mix plant (Pan mixer) Etcetera complete. With fine aggregate (Crushed sand Verticle Shaft Impactor Grade) |
| 13 | Providing and laying in situ /Ready Mix cement concrete Mix-20 of trap / granite /quartzite/ gneiss metal for Reinforced Cement Concrete work in foundations like raft, strip foundations, grillage and footings of Reinforced Cement Concrete columns and steel stanchions Etcetera including bailing out water, Steel centering formwork, laying/pumping cover blocks, compaction and curing roughening the surface if special finish Indian Standards to be provided (Excluding reinforcement and structural steel) Etcetera complete, with fully automatic micro processor based Programmable logic controller with Supervisory Control and Data Acquisition enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) Etcetera complete. With fine aggregate (Crushed sand Verticle Shaft Impactor Grade) |
| 14 | Providing and laying Cast in situ/Ready Mix cement concrete in Mix-20 of trap/ granite/ quartzite/ gneiss metal for Reinforced Cement Concrete pardi of required thickness including steel centering, formwork, cover blocks, laying/pumping, compacting, curing, finishing and rougheningthem if special finish Indian Standards to be provided and curing complete.(Excluding reinforcement and structural steel).with fully automatic micro processor based Programmable logic controller with Supervisory Control and Data Acquisition enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) Etcetera complete. With fine aggregate (Crushed sand Verticle Shaft Impactor Grade) |
| 15 | Providing and laying Cast in situ/Ready Mix cement concrete Mix-20 of trap/ granite /quartzite/ gneiss metal for Reinforced Cement Concrete slabs and landings as per detailed designs and drawings including steel centering, formwork, cover blocks, laying/pumping, compaction finishing the formed surfaces with cement mortar 1:3 of sufficient minimum thickness to give a smooth and even surface or roughening if special finish is to be provided and curing etcetra complete, (Excluding reinforcement and structural steel).with fully automatic micro processor based Programmable logic controller with Supervisory Control and Data Acquisition enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etcetra complete. With fine aggregate (Crushed sand Verticle Shaft Impactor Grade) |
| 16 | Providing and fixing in position Thermo Mechanical Treated - FE - 500 bar reinforcement of various diameters for Reinforced Cement Concrete pile caps, footings, foundations, slabs, beams columns, canopies, staircase, newels, chajjas, lintels pardis, copings, fins, arches Etcetera as per detailed designs, drawings and schedules. including cutting, bending, hooking the bars, binding with wires or tack welding and supporting as required complete. |
| 17 | Supplying hard murum/ kankar at the road site, including conveying and stacking complete. |
| 18 | Spreading hard murum/ soft murrum/ gravel or kankar for side width complete. |
| 19 | Compacting the hard murum side widths including laying in layers on each side with vibratory roller including artificial watering Etcetera complete. |
| 20 | Providing and Laying hot applied thermoplastic road marking strip on Bituminous Surface of specified shade/ colour of 2.5 milimetre thick including 1.5 Refractive index reflectorizing glass beads @ 250 gramme per square metre Thickness of 2.5 milimetre is exclusive of surface applied glass beads as per Indian Roads Congress 35:2015. Initial Dry reflectivity RL shall be > 250 mcd/sqm/lux measured in the initial 7 days and sustained reflectivity RL of 100 mcd/sqm/ lux and Qd of 100 mcd/sqm/ lux measured at the end of 2 years by means of a Standard Reflectometer of Zehntner, Easylux, Delta make capable of measuring RL and QD both according to Indian Roads Congress 35:2015 clause 15.5. The finished surface to be level, uniform, and free from streaks and holes complete as per direction of Engineer-in-charge and in accordance with applicable specifications.(Refer MORTH Clause 803 for technical Specification and Performance for Indian Roads Congress 35:2015). |
| 21 | Providing and fixing of retro- reflectorised informatory sign board rectangular/Square in shape having area less than 0.9 One Square Meter made out of 2 milimetre aluminum sheet bonded with white retro reflective sheeting of Class B (Type IV High intensity micro-prismatic grade sheeting-HIP) having pressure sensitive/heat activated adhesive retoreflective specified back ground, border and back side retoreflctive symbols, letters, numerals, arrow as per Indian Roads Congress:67-2012 Table No 8.3, supported with back support frame 25 milimetre x 25 milimetre x 3 milimetre, duly painted on back side with two coats of grey stove enamel paint and supported on one no. mild steel angle iron post 75 milimetre x 75 milimetre x 6 milimetre, 3.5 metre long firmly fixed to the ground by means of properly designed foundation with Mix-25 grade cement concrete 45 centimetre x 45 centimetre x 60 centimetre, 60 centimetre below ground level as per approved drawing The angle iron post shall be duly painted with one coat of epoxy primer and two coats of epoxy finish paints having alternate black and white bands of 25 centimetre width including Galvanised Iron fixures and transportation etc.complete.The nut bolts of board with angle iron post/supporting structure after fixing at site has to be electrically welded. Class B (Type IV High intensity micro-prismatic grade sheeting-HIP) sheeting shall have 7 years written warranty from the manufacturer and authorised distributor/convertor issued for field performance including the screen printed areas and cut-out sheeting and cut-out durable transparent overlay film and this warranty certificate in original should be submitted to the Engineer in charge by the contractor/supplier. |
| 22 | Supplying and Fixing of Molded Shank Raised Pavement Markers / Cat's Eye made of polycarbonate and ABS moulded body and reflective panels with micro prismatic lens capable of providing total internal reflection of the light entering the lens face and shall support a load of 16000 kilogramme tested in accordance to ASTM D 4280 Type H and complying to Specifications of Category A of MORTH Circular No RW/NH/33023/10-97 DO III Dt 11.06. 1997. The height, width and length shall not exceed 50 milimetre, 100 milimetre and 102 +/- 2 milimetre and with minimum reflective area of 13 Square centimetre on each side and the slope to the base shall be 35 +/- 5 degree. The strength of detachment of the integrated cylindrical shanks, (of diameter not less than 19 +/- 2 milimetre and height not less than 30+/- 2 milimetre) from the body is to be a minimum value of 500 Kilogramme Fixing will be by drilling holes on the road for the shanks to go inside, without nails and using epoxy resin based adhesive as per manufacturer's recommendation and complete as directed by the engineer. The contractor shall submit a two year warranty for satisfactory field performance including stipulated retro-reflectance of the reflecting panel, to the Engineer. |
| 23 | Providing and laying cement concrete pipe of Indian Standards 458:2003 Non Pressure-3 class of 600 milimetre diameter in proper line, level and slope Etcetera complete. |
| 24 | Dismantling stone masonry in lime or cement mortar including stacking the materils asdirected with all leads, lifts etcetra. |
| 25 | Excavation for foundation in earth, soils of all types, sand, gravel, soft murum including shoring and strutting, dewatering as necessary and disposing off excavated stuff as directed Etcetera complete. (By Mechanical Means) a) Upto 1.50 metre lift Normal Rate |
| 26 | Excavation for foundation in hard murum including shoring and strutting, dewatering as necessary and disposing off excavated stuff as directed Etcetera complete. a) Upto 1.50 metre lift Normal Rate |
| 27 | Excavation for foundation in hard rock by chiselling and wedging or line drilling including shoring and strutting, dewatering as necessary and disposing off excavated stuff as directed Etcetera complete. a) Upto 1.50 metre lift Normal Rate |
| 28 | Providing and laying Cast in situ/Ready Mix cement concrete in Mix-15 of trap/ granite/quartzite/gneiss metal for steps including steel centering, formwork, laying/pumping, compacting, roughening them if special finish Indian Standards to be provided, finishing uneven and honeycombed surface and curing Etcetera complete. The Cement Mortar 1:3 plaster Indian Standards considered for rendering uneven and honeycombed surface, only. Newly laid concrete shall be covered by gunny bag, plastic, tarpaulin Etcetera (Wooden centering will not be allowed.), with fully automatic micro processor based Programmable logic controller with Supervisory Control and Data Acquisition enabled reversible Drum Type mixer/concrete Batch mix plant (Pan mixer) Etcetera complete. With fine aggregate (Crushed sand Verticle Shaft Impactor Grade) |
| 29 | Providing and laying in situ / ready mix Mix-25 plain cement concrete of trap /granite/quartzite/ gneiss metal for cast in citu piers, abutment, returns, wings Etcetera including provision of \\"V\\" shaped false joints to form suitable panels on the faces to approve design with compacting by vibrating and curing complete, including plywood/steel form work centering (excluding dewatering by means of pump) and including bailling out water and curing finishing in Cement Mortar 1:3 Etcetera complete. As directed by engineer in charge basic rate shall be increased for height above 5.00 meter in following manners (a) Height upto 5 Metre (With Concrete Mixer)With fine agreegates of required specifications (Verticle Shaft Impactor sand finely washed Etcetera ) i) Height up to 5 metre, normal rate. |
| 30 | Providing and laying in situ / ready mix controlled Mix-25 cement concrete of of trap / granite / quartzite/ gniess metal for reinforced cement concrete caps over piers and abutments including necessary sacffolding plywood/steel formwork, compacting by vibrating, finishing in Cement Mortar 1:3 and curing Etcetera complete. (Excluding reinforcement) With reversible drum type mixer/ concrete batch mix plant (pan mixer). with fine agreegates of required specifications (Verticle Shaft Impactor sand finely washed Etcetera) |
| 31 | Providing and laying in situ / ready mix Mix-20 Reinforced Cement Concrete of trap/ granite/ quartzite/ gneiss metal for Reinforced Cement Concrete work of ballast walls, kerbs and box returns including scaffolding, compaction, formwork finishing and curing Etcetera complete. (excluding reinforcement, with fully automatic micro processor based Programmable logic controller with Supervisory Control and Data Acquisition enabled concrete batch mix plant / pan mixer with fine agreegates of required specifications (Verticle Shaft Impactor sand finely washed Etcetera) Reinforced Cement Concrete work of Ballast walls and Kerb |
| 32 | Providing and laying in situ / ready mix Mix-25 controlled cement concrete of trap/ granite/ quartzite/ gneiss metal for Reinforced Cement Concrete work in solid/ deck slab Etcetera including ramming, vibrating, curing, formwork, centering and finishing in cement plaster excluding reinforcement Etcetera complete. (with fully automatic micro processor based Programmable logic controller with Supervisory Control and Data Acquisition enabled concrete batch mix plant / pan mixer and fine agreegates of required specifications ( Verticle Shaft Impactor sand finely washed Etcetera ) i) Height up to 5 metre, normal rate. |
| 33 | Providing, cutting, bending, hooking, tying and laying in position Thermo Mechanical Treated FE 500 steel bars for reinforcement for all Reinforced Cement Concrete works as per detailed drawings Etcetera complete. |
| 34 | Providing expansion joints with 25 milimetre thick bituminous pad as per detailed drawings Etcetera complete. |
| 35 | Providing and laying weep holes of 100 milimetre diameter Polynvinyl Cloride pipes as per drawing for abutment returns, return walls Etcetera Complete. |
| 36 | Providing tar paper bearing including laying in proper position Etcetera complete. |
| 37 | Providing and laying of filter media with granular materials/ stone crushed aggregates satisfying the requirements laid down in clause 2504.2.2 of Ministry of Roads Transportation and Highway specifications to a thickness of not less than 600 milimetre with smaller size towards the soil and bigger size towards the wall and provided over the entire surface behind abutment, wing wall and return wall to the full height compacted to a firm condition as per drawing and technical specifications Etcetera complete. |
| 38 | Providing and laying 0.90 meter thick metal mat consisting of rubble, oversize metal and normal size metal in specified thickness as per detailed drawing including supplying all materials, hand packing of rubble, spreading metal in layers and hard murum including watering and compaction with power roller etcetra complete. |
| 39 | Providing 100 milimetre diameter Galvanised Iron water spouts as per detailed drawings in Reinforced Cement Concrete slab and wearing surface / kerb Etcetera complete. |
| 40 | Providing selected hard murum filling including laying in layers of 15 to 20 centimetre with watering and compacting Etcetera complete. Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Jul 27, 2026
11:30 IST
Tender Published
Tender notice published.
TodayAug 03, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 7 daysAug 05, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 9 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender