Tender For Repair/Replacement Of Security Lights/Flood Lights, Mes Installation, Dg Sets Amf Panel, Earthing Pits, Lightening Arrestors And Other Misc E/M Works At Af Stn Basant Nagar Under Aor Of Ge (Af) Faridabad
Tender Value
46 Lakhs
Estimated cost
Bid Submission
08 Aug 2026
11 days left
EMD
92000
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
New Delhi → Delhi
EMD Exemption
Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender for Repair/Replacement Of Security Lights/Flood Lights, Mes Installation, Dg Sets Amf Panel, Earthing Pits, Lightening Arrestors And Other Misc E/M Works At Af Stn Basant Nagar Under Aor Of Ge (Af) Faridabad
BOQ
| Sl. No. | Item Description |
| 1 | M&L for General Servicing of DG sets 320 KVA , comprising of Cleaning & greasing of the parts, Tappet setting as per standard, Fan belt, tensioner pulley and lever adjustments, Tightening of all the nuts, bolts and clamps, Testing & checking of AC & DC Wiring, Self & Charging Alternator cleaning and testing, checking of working & minor fault removal, Checking of Supply & return fuel pipes from fuel tank to engine, Cleaning of hydraulic governer complete set. Checking of FIP timing by Fuel cut off method including Transportation, Labour charges & minor material required for servicing etc. as reqd complete all as specified and directed.Note: (i) Cost of unserviceable items will be measured and paid seperately under relevant items.(ii) Item no 2 to 20 is catered for 320KVA 6K12TA DG Sets |
| 2 | Supply and fix oil filter assly complete all as specified and directed. |
| 3 | Supply and fix cartridge oil filter complete all as specified and directed. |
| 4 | Supply and fix head oil filter complete all as specified and directed. |
| 5 | Supply and fix oil cooler assly with housing and element complete all as specified and directed. |
| 6 | Supply and fix oil cooler gasket oil pipe complete all as specified and directed. |
| 7 | Supply and fix cooling water pipe complete all as specified and directed. |
| 8 | Supply and fix cooling water pipe housing thermostat complete all as specified and directed. |
| 9 | Supply and fix cooling water pipe element thermostat complete all as specified and directed. |
| 10 | Supply and fix cooling water pump assly complete all as specified and directed. |
| 11 | Supply and fix impeller water pump complete all as specified and directed. |
| 12 | Supply and fix cooling fan complete all as specified and directed. |
| 13 | Supply and fix intake and exhaust manifold assly with ring gasket and bolt complete all as specified and directed. |
| 14 | Supply and fix turbo charger assly complete all as specified and directed. |
| 15 | Supply and fix nozzle and holder assly complete all as specified and directed. |
| 16 | Supply and fix nozzle complete all as specified and directed. |
| 17 | Supply and fix fuel injection pipe complete all as specified and directed. |
| 18 | Supply and fix fuel injection pump complete all as specified and directed. |
| 19 | Supply and fix governor assly complete all as specified and directed. |
| 20 | Supply and fix fuel filter assly complete all as specified and directed. |
| 21 | M&L for General Servicing of DG sets 80 KVA , comprising of Cleaning & greasing of the parts, Tappet setting as per standard, Fan belt, tensioner pulley and lever adjustments, Tightening of all the nuts, bolts and clamps, Testing & checking of AC & DC Wiring, Self & Charging Alternator cleaning and testing, checking of working & minor fault removal, Checking of Supply & return fuel pipes from fuel tank to engine, Cleaning of hydraulic governer complete set. Checking of FIP timing by Fuel cut off method including Transportation, Labour charges & minor material required for servicing etc. as reqd complete all as specified and directed.Note: (i) Cost of unserviceable items will be measured and paid seperately under relevant items.(ii) Item No 22 to 40 is catered for 80KVA CG DG Sets |
| 22 | Supply and fix oil filter assly complete all as specified and directed. |
| 23 | Supply and fix cartridge oil filter complete all as specified and directed. |
| 24 | Supply and fix head oil filter complete all as specified and directed. |
| 25 | Supply and fix oil cooler assly with housing and element complete all as specified and directed. |
| 26 | Supply and fix oil cooler gasket oil pipe complete all as specified and directed. |
| 27 | Supply and fix cooling water pipe complete all as specified and directed. |
| 28 | Supply and fix cooling water pipe housing thermostat complete all as specified and directed. |
| 29 | Supply and fix cooling water pipe element thermostat complete all as specified and directed. |
| 30 | Supply and fix cooling water pump assly complete all as specified and directed. |
| 31 | Supply and fix impeller water pump complete all as specified and directed. |
| 32 | Supply and fix cooling fan complete all as specified and directed. |
| 33 | Supply and fix intake and exhaust manifold assly with ring gasket and bolt complete all as specified and directed. |
| 34 | Supply and fix turbo charger assly complete all as specified and directed. |
| 35 | Supply and fix nozzle and holder assly complete all as specified and directed. |
| 36 | Supply and fix nozzle complete all as specified and directed. |
| 37 | Supply and fix fuel injection pipe complete all as specified and directed. |
| 38 | Supply and fix fuel injection pump complete all as specified and directed. |
| 39 | Supply and fix governor assly complete all as specified and directed. |
| 40 | Supply and fix fuel filter assly complete all as specified and directed. |
| 41 | Supply and pouring genuine Engine oil complete all as specified and directed. |
| 42 | Supply and pouring super plus Coolent complete all as specified and directed. |
| 43 | Supply and fix distilled water complete all as specified and directed. |
| 44 | Supply and fix Battery terminals , lugs , bolts complete all as specified and directed. |
| 45 | Supply and fix Battery leads copper conductor multi wired 50 Sqmm complete all as specified and directed. |
| 46 | Supply and fix Battery leads copper conductor multi wired 35 Sqmm complete all as specified and directed. |
| 47 | Supplyand fix Hinges for DG set door of any size, any type as required on site complete all as specified and directed. |
| 48 | M&L for Dismantling the radiator and fan from the engine for cleaning of copper tubes and cooling fins by descaling solution and using air compressor ,soldering on leakage, patch work and re-assembling the radiator and fitted with DG set properly including replacement of radiator hose pipe with clamps and bolt/nut with washer, leak check and pressure testing including transporting to repair workshop and bringing back for upto 80 KVA complete all as specified and directed. |
| 49 | All as per item No 48 but capacity 320 KVA |
| 50 | Supply and replacement of low lube oil pressure sensor upto 80 KVA DG Set complete all as specified and as directed. |
| 51 | Supply and replacement of low lube oil pressure sensor upto 320 KVA DG Set complete all as specified and as directed. |
| 52 | M&L for removal & replacement of fly wheel gear ring suitable for upto 80 KVA DG set connection & testing complete all as specified and directed. |
| 53 | All as per item No 52 but capacity from 320 KVA |
| 54 | Supply and fixing in repair of AVR for DG set having capacity 80 KVA complete all as specified and directed. |
| 55 | All as per item No 54 but capacity from 320 KVA |
| 56 | Supply and fixing and testing for smoothing fuctioning Fan Belt suitable for DG set up to 80 KVA complete all as specified and directed. |
| 57 | All as per item No 56 but capacity 320 KVA. |
| 58 | Supply and fixing in all type of hose pipe with clamps , over flow pipe, copper tube fuel supply pipe, etc with clip and complete fittings suitable for DG set upto 80 KVA complete all as specified and directed. |
| 59 | All as per item No 58 but capacity from 320KVA |
| 60 | S&F for fuel hose pipe from fuel filter to fuel pump for DG set upto 80 KVA complete all as specified. |
| 61 | S&F for fuel hose pipe from fuel filter to fuel pump for DG set upto 320 KVA complete all as specified. |
| 62 | S&F for fuel pipe from fuel tank to fuel filter for DG Set 80 KVA complete all as specified. |
| 63 | S&F for fuel pipe from fuel tank to fuel filter for DG Set 320 KVA complete all as specified. |
| 64 | Supply and fixing mounting rubber bushing set of 6 for existing generator complete all as specified and as directed. |
| 65 | S&F of under/over voltage relay 3 phase 415V for DG set of capacity upto 200 KVA all as specified and directed. |
| 66 | Supply & Fixing in repair of Battary Charger 12V DC, 5 Amp of Autocut Electrical Battery Charger Unit SMPS with Constant Voltage Output with Battery Charging Transformer and Moulded Rectifier Unit etc suitable for smoothing functioning of DG set as required on site complete all as directed and specified by engineer in charge. |
| 67 | All as per item No 40 but capacity Battary Charger 24V DC, 10 Amp. |
| 68 | Supply & Fixing in DC 12V Stop Solenoid Coil suitable for DG Set complete all as specified and directed. |
| 69 | Supply & Fixing in DC 24V Self Solenoid Coil suitable for DG Set complete all as specified and directed. |
| 70 | Supply and replacement of Battery 12 Volt 100 AH suitable DG set complete all as specified and directed. |
| 71 | Supply and replacement of Battery 12 Volt 180 AH suitable DG set complete all as specified and directed. |
| 72 | M&L for repairing of self starter of DG set capacity 12 Volts including transporting upto workshop to carry out necessary replacement of burnt copper winding with new copper winding/ coil of existing gauge from rotor and stator coil, cleaning of slots, dryings varnishing and proper insulating to winding complete all as specified and directed. |
| 73 | All as per item No 72 but capacity 24 Volts. |
| 74 | M&L for carrying out complete over hauling/servicing of DG set panel /AMF panel/control panel including checking and rewiring of faulty electrical circuit using 1.5 Sqmm FRLS copper conductor for DG set of any type/make /capacity and making all electric connection and testing for smooth operation complete all as specified and directed. |
| 75 | M&L for carrying out complete over hauling/servicing of DG set plc based auto syncronized panel including checking and rewiring of faulty electrical circuit using 1.5 Sqmm FRLS copper conductor for DG set of any type/make /capacity and making all electric connection and testing for smooth operation complete all as specified and directed. |
| 76 | Labour only for rectification of fault in AMF panel of DG set and testing on load ranging from 80KVA complete all as specified and directed. |
| 77 | Material and Labour for rectification of fault in LT cum PLC based sync panel of DG set and testing complete all as specified and directed. |
| 78 | M&L for replacement of relay of AMF panel 80 KVA DG Set complete all as specified and directed. |
| 79 | M&L for replacement of display panel of AMF suitable for DG set rating 80 KVA along with all connections and push buttons for mode change and start stop button complete all as specified and directed. |
| 80 | S&F in repairs MCCB 3 pole 415 volts fixed type 160 Amps with braking capacity 25KA after taking out old U/S one complete all as specified and directed. |
| 81 | S&F in repairs MCCB 3 pole 415 volts fixed type 200 Amps with braking capacity 36KA after taking out old U/S one complete all as specified and directed. |
| 82 | S&F in repairs MCCB 3 pole 415 volts fixed type 250 Amps with braking capacity 36KA after taking out old U/S one complete all as specified and directed. |
| 83 | S&F Contactor, (4 Pole AC & DC Control) operational current AC1,160 Amps,poles composition- 4NO,DC control ref-LP1D80004 of TC complete all as specified and directed. |
| 84 | S&F Contactor, (4 Pole AC & DC Control) operational current AC1,125 Amps,poles composition- 4NO,DC control ref-LC1DT125A of TC complete all as specified and directed. |
| 85 | S& F Panel LED indication lamps (R/Y/B) complete all as specified and directed. |
| 86 | S&F Rotary switch of existing make complete all as specified and directed. |
| 87 | S&F in repairs digital volt meter ,415 volts,including after taking out old unserviceable one complete all as specified and directed. |
| 88 | S&F in repairs digital Ammeter,415 volts grade,100 Amps rating,including and after taking out old unserviceable one complete all as specified and directed. |
| 89 | M&L for attending of any breakdown of standby power supply in any location, whenever required round the clock, rectify the fault and restore the standby supply within three hours after receipt of complaint of any nature ie engine, alternator, control panel/AMF pael etc complete all as specified and directed.Note- (i) The cost of replaced spare parts will be paid and measure seperatly. (ii) If complaint is not attended by contractor with in five hours the penalty of Rs 500/- per hour to be imposed and amount of penalty will be deducted from RAR. (iii) The cost of transportation (to and from) for all kind of necessary equipment /T&P shall be arranged/brought by contractor to complete the job at site or at E/M Yard and no extra cost shall be paid to the contractor to this effect. (iv) Complaint shall be lodged by telephonically so contractor to specify the telephone/mobile No who will receive the complaint round the clock. |
| 90 | Supply and fix in replacement of Onload Changeover switch 630 Amp, 4 pole ,415 V,50 Hz in sheet metal enclosure complete all as specified and directed. |
| 91 | M& L for welding each canopy door to the outer unit for proper closing and opening including hinges and repainting complete all as specified and directed. |
| 92 | M&L spray gun painting of generator upto 80 KVA in existing colour with smooth finishing compete all as specified and as directed. |
| 93 | M&L spray gun painting of generator 320 KVA in existing colour with smooth finishing compete all as specified and as directed. |
| 94 | M&L for Design ,development ,supply commisiong and testing chemical earthing burnished metallic brown 99.99% pure copper material specially develpoed for earthing purpose terminal exothermic/ nut bolt/ breezing . ground tubular effective chemical earthing (CPRI tested for 25KA current capacity for LT line ) highly anticorrosive long life eletrode with and including adequate protective coating to withstand servere weather condition in the earth pit of the standard size comprising of 40 mm 3m long copper rod as primary conductor and hollow copper tube of 80 mmx 3 m long with alosing base plate of 80 mm secondary conductor to install with suitable connecting terminal cofirming of IS 3043 1987 specification highly conductive packing material to be filled in earth pits for providing uniform low resisitivity anticorrosive ,hygroscope medium around the earth system for improving the efficiency of current dissipation with cystalline conductive mixture CCM 25 kg per bag sufficient quantities required at site complete RCC earthing pit cover material and labour complete bfc compound specified and as per ic 62561 acceptance chemical test Leaching, sulphur determination, corrosion, resistivity along with CPRI and chemical compound test reportNote :-1. Excavation / drilling hole in hard rock is included in the rate quoted incld. T&P2. Min. resistance for earthing pit shall be less than 1 ohm.3. Drilling or earth work shall be included in the overall cost quoted by the contractor. |
| 95 | S & F in repairs Earth test box made of powder coated, 3.15 mm thick, CRCA sheet,20 cm x 20 cm x 10 cm size conforming to CPRI approved and IP-65 protection class,right hinge openable type including mounting arrangement such as making hole in wall,providing MS clamp,nut,bolt etc complete manufactured through approved manufacturers complete all as specified and directed. |
| 96 | S&F in repair wall mounted TPN busbar chamber factory made with busbar of current rating 400 Amp, 415, 4 way complete all as specified and directed. |
| 97 | S & F rubber insulation mat of size 1.8 mtr x0.9mtr wide 2mm thick red/green/blue colour ISI marked embozzed for up to 33 KV complete all as specified and directed. |
| 98 | M&L for earthing complete with galvanised steel earth plate electrode 600 x 600 x 6mm thick burried directly in ground earth pit not less than 2.25 M deep below ground level with top edge of the plate not less than 1.5 M below normal ground level connected to galvanised strip of 25x4 mm by means of nuts, bolts, checknuts, washers of galvanised iron or steel all as shown in electrical plate No. 3 of SSR Part I of 2009 connected to and including earthing test point or disconnecting / testing link including excavation/ earth work in any strata, removal of surplus earth, GI pipe for watering and funnel, GI Pipe medium grade 40mm dia for earth lead protection, PCC 1:3:6 type C1 chamber with chamber cover in RCC 1:2:4 type B1 complete all as specified and directed. |
| 99 | M & L in repairs earthing complete with galvanised steel earth plate electode 600 x 600 x 6.0 mm thick burried directly in ground earth pit not less than 2.25 mtr deep below ground level connected to & including galvanised steel wire 4.0 mm dia size means of nuts and bolt check nuts and washers of galvanised rion sheet all as shown in electrical plate Nos 5 of SSR Part - I and connected to earthing test point complete including testing filling of adquate quantity of charcoal dust and common salt including refilling earth and removal of surplus soil upto 50 mtrs PCC 1:3:6 type CI chamber precast RCC cover 40 mm thick reinforced with 6 mm dia MS bar 3 Nos both way with handle made out of 6 mm dia MS bar water pipe with wire mesh and connecting testing etc complete all as specified and directed. |
| 100 | M&L for Design ,development ,supply commisiong and testing grid earthing burnished metallic brown 99.99% pure copper material specially develpoed for earthing purpose T point terminal exothermic/ nut bolt/ breezing . ground tubular effective chemical earthing (CPRI tested for 25KA current capacity for LT line ) highly anticorrosive long life eletrode with and including adequate protective coating to withstand servere weather condition in the earth pit of the standard size comprising of 40 mm 3m long copper rod as primary conductor and hollow copper tube of 80 mmx 3 m long with alosing base plate of 80 mm secondary conductor to install with suitable connecting terminal cofirming of IS 3043 1987 specification highly conductive packing material to be filled in earth pits for providing uniform low resisitivity anticorrosive ,hygroscope medium around the earth system for improving the efficiency of current dissipation with cystalline conductive mixture CCM 25 kg per bag sufficient quantities required at site complete RCC earthing pit cover material and labour complete bfc compound specified and as per ic 62561 acceptance chemical test Leaching, sulphur determination, corrosion, resistivity along with CPRI and chemical compound test reportNote :-1. Excavation / drilling hole in hard rock is included in the rate quoted incld. T&P2. Min. resistance for earthing pit shall be less than 1 ohm.3. Drilling or earth work shall be included in the overall cost quoted by the contractor. |
| 101 | M&L in replacement Test point terminal block made of gun metal or phosphorus bronze size 75x75x25mm drilled and screwed including 3 nos. 8mm dia 25mm long hex. head screw complete all as specified and directed. |
| 102 | Supply and fix gi steel wire 4mm complete with saddles and fixing screws etc for roof conductors and down conductors above ground level including removing u/s strips complete all as specified and directed. |
| 103 | Supply and fix aluminium strip 25mm x 4 mm mm complete with saddles and fixing screws etc for roof conductors and down conductors above ground level including removing u/s strips complete all as specified and directed. |
| 104 | Supply and fix aluminium strip 32 mm x 6 mm complete with saddles and fixing screws etc for roof conductors and down conductors above ground level including removing u/s strips complete all as specified and directed. |
| 105 | Supply and fix copper strip 20mm x 3mm complete with insulators and fixing screws etc for roof/wall above ground level including removing u/s strips complete all as specified and directed. |
| 106 | Supply and fix single pointed air termination aluminium rod,12 mm dia, 300 mm long all as specified and directed. |
| 107 | Supply and fix single pointed air termination copper rod,12 mm dia, 300 mm long all as specified and directed. |
| 108 | S&F DMC (Dough Moulding Compound) strip holder on wall and roof of suitable size including removing broken u/s one complete all as specified and directed. |
| 109 | M&L 32 mm GI pipe light grade of 1.3 mtr piece fixing in PCC cubical and complete connection of existing air termination rod complete all as specified and as directed, |
| 110 | M&L for PCC M-25 using 20 mm graded stone aggregate) as in coping and necessary form work, weathering slightly rounded or chamfered angles and throating etc complete all as specified and directed. |
| 111 | M&L for repair to earth chambers by demolishing unserviceable earth chambers and fixing new chambers of PCC 1:3:6 type C1 as per electrical plate no.3 of SSR part-I |
| 112 | M&L for repair to earth chamber cover by removing unserviceable earth chambers cover and fixing new cover complete all as specified and directed. |
| 113 | M&L for CI plate triangular with 500 mm long spike for writing earthing name and value complete all as specified and directed. |
| 114 | M&L for point wiring with single core FRLS PVC insulated unsheathed 1100 volt grade cable with stranded copper conductor of size 1.5 Sq mm (Nominal area) drawn through in enamelled steel conduit suitable for flameproof switch/socket/LED Bulk Head ligh/Fluorescent LED fixed on wall, ceiling with GI saddles GI screws, rawal plugs (concealed conduit wiring) with all fittings including Tee, junction boxes and provision of modular metal flush box of suitable size modular white cover plate with frame for mounting switch sockets and regulators and drawing continuous earth wire with and including PVC insulated unsheathed 1100 volts grade cable with stranded coper conductor of size 1.5 Sq mm (Nominal area) complete all as specified and directed.(a) One light point controlled by one switch complete all as specified and directed. |
| 115 | Supply and fix Fluorescent LED tube light fitting 1 x 16/20W flameproof type made of Die cast aluminium alloy housing with heat resistant glass/heat resistant dome glass/extrenal reflector with CMRI certified LED FLameproof well glass luminaire for gas/vapour grtoup of IIA & IIB ans Zone 1 & IP65 protection etc. complete with all accessories prewired and including connecting up with three core twisted flexible copper conductor cable with suitable size complete all as specified and directed. |
| 116 | Supply and fix Fluorescent LED tube light fitting 1 x 8 W flameproof type made of Die cast aluminium alloy housing with heat resistant glass/heat resistant dome glass/extrenal reflector with CMRI certified LED FLameproof well glass luminaire for gas/vapour grtoup of IIA & IIB ans Zone 1 & IP65 protection etc. complete with all accessories prewired and including connecting up with three core twisted flexible copper conductor cable with suitable size complete all as specified and directed. |
| 117 | Supply and Fixing of Flameproof cum Waterproof LED Bulk Head light fitting of 15W, IP66 protection of Cast Aluminum alloy material and Heat and Impact resistance toughen 'A' clear glass having Anti corrosive epoxy powder coated finish complete with all accessories pre wired and including connecting up with three core flexible copper conductor cable with suitable size complete all as specified and directed. |
| 118 | S & F flame proof exhaust fan 305 mm (12)\\" sweep heavy duty 1440 RPM, single phase 240 volts AC 50 Hz and connecting up complete including louvers and provision of cable 3 core of size 0.5 sqmm (16/0.2 mm) from ceiling rose to fan and connecting up with three core twisted flexible copper conductor cable with suitable size complete all as specified and directed. |
| 119 | Supply and fix switch flame proof rotary type with termination box in LM6, 16A, single pole 250V complete all as specified and directed. |
| 120 | Suppply and fix flame proof switch socket & plug combined in LM 6 cable termination box in LM6, 16A, 250V, 2P+earth, complete all as specified and directed. |
| 121 | Supply and installation in replacement of display boards of approx size 2000mm x 600mm x 10mm stencil-cut GI fascia normal flat letters backed with acrylic ensuring the text glows cleanly from the internal LEDs , internal structural framework using heavy-duty MS/GI hollow tubular sections (16-gauge). Includes full-seam welding, joint grinding, and application of 2 coats of anti-rust zinc-chromate primer followed by 2 coats of epoxy enamel paint. GI Fascia & Flat Luminous Letters 18-gauge (1.2mm) GI sheet, pan-formed into a seamless box. Normal flat letters to be precision laser-cut into the GI sheet and backed with 3mm UV-stabilized cast acrylic. Board and cut-outs to be painted with automotive PU paint to ensure letters glow uniformly with LED backlight. Exact text, font, and paint specifications will be directed by the Engineer-in-Charge. Internal LED Illumination of high-brightness, IP67-rated LED modules (SMD 2835 or 5050, >100 lumens/watt) with 160-degree wide-angle optical lenses. LEDs to be mounted on the internal back panel to provide uniform, shadow-free illumination through the flat acrylic-backed letters. with outdoor-rated IP67 Constant Voltage 12V DC SMPS with built-in overload protection, sized with a minimum 20% safety margin. Includes all internal FRLS multi-strand copper wiring, PVC flexible conduits, and waterproof IP68 gel connectors. Safe hoisting, alignment, and secure wall/structure mounting of the complete sign board. Includes the use of SS 304 grade fasteners, heavy-duty chemical anchors or rawl bolts, and drilling 3mm weep holes at the bottom of the GI box for moisture drainage complete all as specified and directed. |
| 122 | Taking down carefully aluminum/copper point wiring (light, fan, switch, socket, power point, holder) complete includind fittings and fixtures and making good disturbed surfaces of walls, floor to match with existing specification complete and all as specified keeping aside serviceable items for reuse with in the same bldg and removing U/S items from site complete all as specified and directed.Note : Refixing of serviceable fitting shall be measured and paid seperately. |
| 123 | Taking down carefully copper / aluminum two core sub main wiring of sizes 4/6 Sqmm cable any type and removing old material from site and making good disurbed surface complete all as specified and directed. |
| 124 | M&L in repairs,two single core PVC insulated cable with copper conductor multi stranded 4 Sqmm duly drawn through and including concealed PVC conduit suitable size as sub main with continuous earth wire 6 Sqmm size and connecting to common earth dolly complete all as specified and directed.Note :- Flexible Copper Wire Used In FRLS. |
| 125 | M&L for point wiring in repairs complete with 1.5 sqmm single core multistranded copper conductor PVC insulated and unsheathed cable 1100 volts grade FRLS cable IS-694 marked drawn through and including non metallic rigid PVC conduit medium duty ISI marked not less than 20mm dia, fixed in wall, on roof with GI saddles GI screws, rawal plugs (concealed conduit in wall wiring) with all fittings including Tee, junction boxes and provision of 2 mm thick pressed steel terminal box of suitable size with 3 mm thick hylam laminated white sheet cover for mounting switch sockets and regulators and drawing continuous earth wire with and including PVC insulated unsheathed 1100 volts grade cable with multistranded coper conductor of size 1.5 Sq mm (Nominal area) complete all as specified for following (Color coding to be followed) |
| 126 | All as per Item No 125 above but one three pin 5 Amps socket out let on the same board with other switches with 1.5 sq mm PVC insulated copper conductor for continuous earthing. |
| 127 | All as per item No 1255 above before but one three pin 5 Amps socket out let on independant board with 1.5 sq mm PVC insulated copper conductor for continuous earthing. |
| 128 | All as per item No 125 above before but 15 Amps 3 pin socket outlet on independent board with 4 sq mm PVC insulated and sheathed copper conductor with 4 sq mm PVC insulated copper conductor single core for continuous earthing. |
| 129 | S&F Piano switch in repairs, flush button,single pole,one way 5/6 Amp complete all as specified and directed. |
| 130 | S&F piano switch,in repairs, flush button single pole one way 15/16 Amp complete all as specified and directed. |
| 131 | S&F socket outlet, in repairs,flush type 2 in 1, 2 pin and 3 pin 5 Amp complete all as specified and directed. |
| 132 | S&F socket outlet, in repairs,flush type 2 in 1, 3 pin and 6/16 Amp complete all as specified and directed. |
| 133 | S&F stepped type electronic fan regulator, in repairs, flush type on the existing phenolic laminated sheet etc, complete all as specified and directed. |
| 134 | S&F in repairs,ceiling rose surface backlight, 65 x 50 mm two to to three terminals complete all as specified and directed. |
| 135 | S&F in repairs,LED tube light batten, 20W(+) 2% LED 6000K (4 ft.), 230 volts AC,Wall mounted LED batten, extruded aluminium heat sink provided for efficient heat dissipation & integrated electronic driver connector block,lamp etc complete with all accessories, internally pre-wired including twin core twisted flexible copper conductor of suitable size with PF -0.95,THD-10%,driver should be of same make as LED fitting,with in build over voltage ,under voltage and short circuit protection with operating range of 140 volst to 280 volts,isolation LED driver complete all as specified and directed. |
| 136 | S&F in repairs,sheet metal enclosure for MCB DB's SPN 240 volts, 4 way with neutral bus bar 200 Amp rated double door type regal grey complete all as specified and directed. |
| 137 | S&F in repairs MCB SP 6 to 32 Amps 240 Volts.\\"B\\" grade complete all as specified and directed. |
| 138 | S&F in repairs MCB SPN, 40 Amps, 240Volts .\\"B\\" grade complete all as specified and directed. |
| 139 | Supply and fix exhaust fan, heavy duty steel body AC single Phase. 230V of size 4500m sweep with, blades, and frame and louvers complete all as specified and directed. |
| 140 | S& fixing LED flood light luminarie 120 W with high pressure die cast housing acting as heat sink in order to ensure better performance having IP66 ingress protection complete all as specified and directed.Note : All T&P ie ladder,Tools,Safty glooves etc will be provided by the contractor without any extra cost to height upto 25 mtr |
| 141 | M& L for preparation of trench for cable laying of size 300mm x 450mm x 10 m long including excavation & earth work in any type of soil brick work in CM 1:4, PCC work in 1:2:4 type B-1 using 20mm graded stone aggregate, plaster in CM 1:4 finished even & fair complete all as specified and directed. |
| 142 | Supply and fix cable duct cover made of MS of size 300mm x 450mm x 1m of thickness 3.0 mm complete all as specified and directed. |
| 143 | Taking down unserviceable street light fitting upto 11 mtrs /LED Street Light fitting/Flood light Fitting of any size from the pole/bldg and kept in safe custody for refixing or for schedule of credit to contractor complete all as specified and directed. Note : All T&P ie ladder,Tools,Safty glooves etc will be provided by the contractor without any extra cost |
| 144 | Refixing and reconnecting up complete LED street light/Flood light fitting after rectification of defects in wiring of the fitting in an including replacement of holders, PVC connector, ballast, ignitor, condesor and lamp and making electric connection with PVC unsheathed wire with old or new conductor with OH line or Bus bar box complete all as specified and directed. Note : All T&P ie ladder,Tools,Safty glooves etc will be provided by the contractor without any extra cost |
| 145 | Supply and fix in replacement post top lantern LED 40 W or next highest wattage having IP65 protction for single phase connection 50 Hz 230 Volts complete all as specified and directed. |
| 146 | Supply and Fixing LED street light fitting 45 Watt pressure die case aluminium housing LED street light luminaires suitable for existing street light pole including all fixing accessaries complete all as specified and directed. |
| 147 | Supply and Fixing LED street light fitting 60 Watt pressure die case aluminium housing LED street light luminaires suitable for existing street light pole including all fixing accessaries complete all as specified and directed. |
| 148 | S& fixing LED flood light luminarie 70 W with high pressure die cast housing acting as heat sink in order to ensure better performance having IP66 ingress protection acomplete all as specified and directed.Note : All T&P ie ladder,Tools,Safty glooves etc will be provided by the contractor without any extra cost to height upto 25 mtr |
| 149 | S& fixing LED flood light luminarie 100 W with high pressure die cast housing acting as heat sink in order to ensure better performance having IP66 ingress protection complete all as specified and directed.Note : All T&P ie ladder,Tools,Safty glooves etc will be provided by the contractor without any extra cost to height upto 25 mtr |
| 150 | S& fixing LED flood light luminarie 200 W with high pressure die cast housing acting as heat sink in order to ensure better performance having IP66 ingress protection complete all as specified and directed. |
| 151 | Supply and fix single phase driver for LED street light / flood light of 45 to 200 watt capacity and compatible with existing street light/ flood light any type / any rating complete all as specified and directed. |
| 152 | S&F in replacement street light GI pipe bracket 50 mm dia 1.50metre length (ISI marked) light grade bend to shape with two Nos MS clamp duly painted nuts and bolts etc complete all as specified and directed. |
| 153 | M&L for scrapping of surface of steel tubular poles of any size with emery paper and painting of pole one coat of primer and two coats of silver colour paint including writing pole No on yellow colour with 30cm strip upto 1.5 Mtr height from ground level complete all as specified and directed. |
| 154 | Supply and fixing automatic street light prewired switch using nature switch for automatic switching of street light based on lux level of nature light.THE SENSOR (NATURE SWITCH) alongwith power contactor for 25 KW 3 phase,MCB pole/wall mountable enclosure made of rust proof electric shock proof terminal proof and FR grade special moulding compound junction box confirming to IP54 with all other accessoried ie lugs cable connedtion etc complete all as specified and directed. |
| 155 | Supply and fix in replacement non-metallic junction box/street light box with three phase aluminium bus bar of suilable for 415 Volt , 50 Hz electric supply conforming to IP65 wall / pedestral mounted and including MCB SPN 06 Amps complete all as specified and directed. |
| 156 | Supply and fix steel pole tubular swaged 9 metres long complete with cast iron base plate , finialtaper plug , bolts , nuts and screws as specified type 410 SP-22 complete all as specified and directed. |
| 157 | Supply and fix in replacement LED bollard fitting 9 Watt with luminaire with MS Pipe housing with glare free PMMA diffuser , IP65 of height 1200 mm suitable for single phase connection 50 Hz 230 Volts complete all as specified and directed. |
| 158 | Supply and errection in true vertical position 6 mtr long MS pole on pcc foundation suitable for 47 m/s wind speed with 4-8, 590mm PCD of foundation bolts complete with MS base plate of 300mmx300mmx6mm at bottom and swages from base to top in such manner that 114.3mm x 3.65mm upto 3 metres, 88.9mm x 3.25mm upto 1.5 metres , 76.1mm x 3.25mm upto 1.5 metres, above base plate with arm to fix solar street light at top and final tape plug, bolts, nuts, washers and screws incl painting with black bituminous paint two coat over one coat or red oxide primer after errection complete and marking pole number on pole complete all as specified and directed.Note : (i) Earth work and PCC foundation work shall be measured and paid separately.(ii) Description as per direction of Engineer-in-Charge will be printed on each pole without any extra cost. |
| 159 | Supply and fix in replacement hot dip galvanized decorative pole 6 m height dual arm light fitting outdoor type including 50 watt luminaire with IP66 rating complete all as specified and directed. |
| 160 | M & L cement concrete in foundation filling and mass concrete type B2 1:3:6 (40mm graded stone aggregate) complete all as specified and directed. |
| 161 | M & L cement concrete in foundation filling and mass concrete type B2 1:4:8 (40mm graded stone aggregate) complete all as specified and directed. |
| 162 | Supply and laying or fixing or passing through pipe, 1100 volts grade heavy duty cable with PVC insulated aluminium conductor served with an inner sheathing of PVC tape with galvanised steel wire or tape and overall PVC sheathed 4 core 10 sq. mm nominal cross section in service connections including takind down old u/s complete all as specified and directed. |
| 163 | Supply and laying or fixing or passing through pipe, 1100 volts grade heavy duty cable with PVC insulated aluminium conductor served with an inner sheathing of PVC tape with galvanised steel wire or tape and overall PVC sheathed 2 core 6 sq. mm nominal cross section in service connections complete all as specified and directed. |
| 164 | Excavation in trenches in soft/loose soil not exceeding 1.5 Mtr wide and not exceeding 1.5 Mtr depth for laying of cables/poles or foundation etc and getting out complete all as specified and directed. |
| 165 | Add to item No 164 for each additional 1.5 mtr or part their of in depth beyond the first 1.5 mtr |
| 166 | Removing of surplus excavated soil to a distance not exceeding 50 Mtr from starting point and depositing where directed at a level not exceeding 1.5 Mtr above the starting point complete all as specified and directed. |
| 167 | Returning, filling, including spreeding leveling watering and well ramming in layers not exceeding 25 cm apart complete all as specified and directed. |
| 168 | Material and labor for sand cushioning to XLPE cable with using clean dry and natural river sand with a layer of 8 cm thick before laying the cable and 15 cm thick layer after laying the cable and this then gently punned down to a thick of 10 cm above the top the upper most cable all as specified and as directed. |
| 169 | Supplying and laying un-reinforced precast concrete cable cover, class LV, Type 1 with peak, size 250 mm x 150mm x 40mm |
| 170 | Supply and Laying,Connecting and testing in repairs cable XLPE insulated armoured heavy duty electric cable with aluminium conductor 1100 Volt grade cross sectional area 25 Sqmm 4 core complete all as specified and directed. |
| 171 | M&l in replacement tubing light grade galvanized iron to be embeded in PCC block fitting complete with 40 mm bore complete all as specified and directed. |
| 172 | Supply and fixing in repair/replacement of solar street light fittings with integrated 12 Watt LED street light system with solar PV Panel 100 WP, integrated LED fitting with Li-Ion Battery 11.1 V 17 Ah , MPPT based solar charge controller,Motion Sensor and tubular pole of height 5 Mtrs complete all as specified and directed. |
| 173 | M&L for servicing and maintenance of high mast pulley and GI wire rope system oilling, greasing etc for smooth functioning of the lowering mechanish complete all as specified and directed. |
| 174 | M&L for rewinding of 0.5 Hp to 1 HP motor of high mast complete all as specified and directed. |
| 175 | Taking down unserviceable street light fitting from fixed type high mast pole 16 to 25 mtrs /LED Street Light fitting/Flood light Fitting of any size from the pole/bldg and kept in safe custody for refixing or for schedule of credit to contractor complete all as specified and directed. Note : All T&P ie ladder,Tools,Safty glooves etc will be provided by the contractor without any extra cost |
| 176 | M&L for refixing after repairing and reconnecting up complete to fixed type high mast pole 16 to 25 mtrs LED street light/Flood light fitting after rectification of defects in wiring of the fitting in an including replacement of holders, PVC connector, ballast, ignitor, condesor and lamp and making electric connection with PVC unsheathed wire with old or new conductor with OH line or Bus bar box complete all as specified and directed.Note : All T&P ie ladder,Tools,Safty glooves etc will be provided by the contractor without any extra cost |
| 177 | Supply and connecting single core FR, PVC insulated stranded copper conductor cable of size 1.5 sqmm for street light passing through pole hole/GI pipe/PVC conduit to junction box and connected electrically including taking down old unsv wire any type any make complete all as specified and directed.NOTE - Three runs of wire is measured as one RM. Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Jul 25, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedAug 08, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 11 daysAug 10, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 13 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender