Tender For Cleaning/Repair Of Sewage Line, Manhole, Septic Tank, Soakage Well, Repair/Replacement Of Internal Wiring, Sockets, Switches Etc And Other Connected Repair At Af Stn Mcc Basant Nagar Under Aor Of Ge (Af) Faridabad.
Tender Overview
Project Description
Tender for Cleaning/Repair Of Sewage Line, Manhole, Septic Tank, Soakage Well, Repair/Replacement Of Internal Wiring, Sockets, Switches Etc And Other Connected Repair At Af Stn Mcc Basant Nagar Under Aor Of Ge (Af) Faridabad.
Corrigendum
| Sr No | Corrigendum Date | Corrigendum | Type | New Submission Date |
|---|---|---|---|---|
| 1 | 08-Aug-2026 | Bid Auto Extn Corrigendum | Bid Auto Extn Corrigendum | 15-Aug-2026 |
BOQ
| Sl. No. | Item Description |
| 1 | Demolition/Dismantling of Brickwork or stone/ boulder masonry, built in cement mortar incl all quoins, arches, pillars, etc complete all as specified and directed. |
| 2 | M&L for Brickwork with subclass 'B' bricks (old size bricks), straight or curved on plan exc 6m mean radius, built in CM 1:6 complete all as specified and directed. |
| 3 | All as per item No 02 above but except bricks. |
| 4 | Taking down cement plaster of any description on concrete surfaces such as soffit of RCC slab, chajjas and brick walls, Ceiing etc including raking out joints, hacking for key, scrubbing down with water etc complete all as specified and directed |
| 5 | M&L for rendering 15mm thick in CM 1:4 on of brick work or concrete surface finish ever and smooth (w/o using extra cement) incl WPC as per user manual complete all as specified and directed. |
| 6 | M&L for preparation of new plaster surface & apply two coats of cement based paint over a coat alkali primer resistance incl one layer of 3mm thick wall care putty on old scraped surfaces or new plasterd surfaces and obtain smooth finish using sand paper complete all as specified and directed. |
| 7 | Demolition of cement concrete (unreinforced) in ground floors and pavings not exceeding 15cm thickness (below or above ground level) including floor finishes/tiling work and disposal of debris complete all as specified and directed. |
| 8 | M & L for 50 mm thick PCC 1:3:6 type C-2 (using 40 mm graded stone agg) as in plinth protection / path/ any paved area complete all as specified and directed. |
| 9 | M&L for 75mm thick PCC type D-2, 1:4:8 (using 40mm graded stone aggregate) as in sub base complete all as specified and directed. |
| 10 | M&L for machine pressed precast concrete interlocking paver block any shape and size confirming to IS 15658 -2006 of 60mm thickness, with grey cement, pigment incl 25mm thick sand filling complete all as specified and directed. |
| 11 | M&L for 60 mm thick machine cut precast concrete inter locking paver block except tile ,(M-35) grade complete all as specified and directed.Note:- Colour as approved by GE. |
| 12 | M&L for 80 mm thick machine cut precast concrete inter locking paver block except tile ,(M-40) grade complete all as specified and directed.Note:- Colour as approved by GE. |
| 13 | M & L for sand filling under floors or in foundation including watering and consolidation complete all as specified and directed. |
| 14 | M & L for chequered tiles of size 300 x 300 x 25 mm thick (colour and glazed approved by EIC) with grey cement and pigments laid over 15 mm thick screed bed in CM 1:6 bedded and jointed in neat cement slurry, incl dismantling complete all as specified and directed. |
| 15 | M&L for 25 mm thick PCC type B-0, 1:2:4 (using 12.5 mm graded stone aggregate) as in laying of floor/sub base finishes complete all as specified and directed. |
| 16 | Cleaning /removal of blockage 150 mm bore SWG pipes of depth not exc 1.50 mtr with mechnical process incl removing RCC man hole covers and refixing the same as before complete all as specified and directed. |
| 17 | Cleaning /removal of blockage 150 mm bore SWG pipes of depth exc 1.50 mtr but not exc 3.00 mtr with mechnical process incl removing RCC man hole covers and refixing the same as before complete all as specified and directed. |
| 18 | Dewatering/desilting of existing manholes of any size depth and removing of all solid/semi-solid matter of silt residue both organic or inorganic in nature (mechanical system or using suction pump where ever required up to any depth )and incl removing RCC manhole Covers and refixing the same after making the manhole fully functional, complete all as specified and directed. |
| 19 | Dewatering/desilting for the septic tank of any capacity exc1.50 m and n.exc 4.5 m deep solid/semi-solid matter of silt residue both organic or inorganic in nature ( mechanical system or using suction pump where ever required up to any depth by working under foul conditions and disposal of the same in out of MoD area, complete all as specified and directed.Note for Item : The Septic tank shall be measured more than one time as per requirment and directed by Egnr-in-Charge. |
| 20 | Excavation in trenches n exc 1.5m wide and n exc 1.5m deep and getting out in soft or loose soil for shafts, wells,drains, manholes etc n exc 10Sqm on plan for sewage line & foundation etc complete all as specified and directed. |
| 21 | All as per item No 20 but exceeding 1.5 M depth and not exceeding 3 M for foundation, etc., and getting out in Soft/ Loose soil. |
| 22 | All as per item No 20 but exceeding 3.0 M depth and not exceeding 4.50M for foundation, etc., and getting out in Soft/ Loose soil. |
| 23 | Demolition and breaking up drain pipes 100mm dia ( Salt Glazed ware, AC or reinforced concrete) set in cement mortar including PCC bed and haunching and removal of debris outside the MD land complete all as specified and directed. |
| 24 | Demoltion and breaking up existing sewag(SWR/ AC pipes and the like, 150mm bore set in cement mortar and removing demolished material to a distance exc 50m and n exc 100m complete all as specified and directed. |
| 25 | Demoltion and breaking up existing sewage (SGSW / AC pipes and the like, 200mm bore set in cement mortar and removing demolished material to a distance exc 50m and n exc 100m complete all as specified and directed. |
| 26 | S&F 110 mm PVC (SWR ) , pipes single socketd , in any length with rubber ring joints, laid in trenches or in floor complete all as specified and directed. |
| 27 | S & F RCC Class NP 3, 150 mm bore pipes laid and jointed complete all as specified and directed. |
| 28 | S & F RCC Class NP 3, 200 mm bore pipes laid and jointed complete with collars, complete all as specified and directed. |
| 29 | M & L for PCC 1:3:6 type C2 (using 40 mm graded granite stone aggregate) in concrete bed to drain pipes including packing under and haunching against the sides of pipes after they are laid and tested for pipes of 100 mm bore, complete all as specified and directed. |
| 30 | M & L for PCC 1:3:6 type C2 (using 40 mm graded granite stone aggregate) in concrete bed to drain pipes including packing under and haunching against the sides of pipes after they are laid and tested for pipes of 150 mm bore, complete all as specified and directed. |
| 31 | M & L for PCC 1:3:6 type C2 (using 40 mm graded granite stone aggregate) in concrete bed to drain pipes including packing under and haunching against the sides of pipes after they are laid and tested for pipes of 200 mm bore. |
| 32 | S & F in repair for precast factry made reinforced cement concrete Manhole cover (Ist quality) including grove and hook arrangement for lifting and placing in position and sides covered by MS sheet medium duty of 60mm thick complete all as specified and directed. Note :- Size of the cover will be itimated by the Engineer-in-Charge. |
| 33 | S&F mild steel work such as in angle iron, flat iron fillets etc for horn, fixing of barbed wire to RCC post, securing wire mesh etc. including all necessary cuttings, drilling, bolting or riveting etc and including 10mm MS bars as in tie bars fixed to fencing posts including necessary welding where required, as per site requirement and other similar works complete, conforming to Fe-290 Gde E-165, complete all as specified and directed. |
| 34 | S&F in repair precast factory made polycrete (SFRC) medium duty perforated drain cover 100 mm thick rectangle in shape upto 01 sqm area each with hole for drain complete all as specified and directed. |
| 35 | Returning, filling in soil including spreading, levelling, watering and well ramming in layers n.exc. 25cm complete all as specified and directed. |
| 36 | M&L for Plain cement concrete (1:2:4) Type B-1, (using 20mm graded crushed stone aggregate), as in copings, kneelers , apex stones,bed plates, including weathering ,slightly rounded /benching or chamfered angles and throating complete all as specified and directed.Note :-Rates include for use of formwork. |
| 37 | Cutting into existing manholes for connecting new drains making good to pipe and rendering cutting out existing benching for and forming branch channel (1/2 round or 3/4 round section) in cement concrete 1:2:4 type B1, smooth finished and reforming benching as required, 100mm dia pipe, complete all as specified and directed. |
| 38 | Cutting into existing manholes for connecting new drains making good to pipe and rendering cutting out existing benching for and forming branch channel (1/2 round or 3/4 round section) in cement concrete 1:2:4 type B1, smooth finished and reforming benching as required, 150mm dia pipe, complete all as specified and directed. |
| 39 | Cutting into existing manholes for connecting new drains making good to pipe and rendering cutting out existing benching for and forming branch channel (1/2 round or 3/4 round section) in cement concrete 1:2:4 type B1, smooth finished and reforming benching as required, 200mm dia pipe, complete all as specified and directed. |
| 40 | M&L for salt glazed stoneware gully trap, square or round moulded type 'P', 150x150mm size, complete all as specified and directed. |
| 41 | M&L for cement concrete 1:3:6 type C2 (using 20 mm graded stone aggregate) as in surface channels, drains and bed of manhole complete all as specified and directed. |
| 42 | Extra for forming fair finished drain or channel 30 cm inner girth in cement concrete, using extra cement, including forms, moulds, mitred/stopped ends etc, complete all as specified and directed. |
| 43 | M&L for cement concrete 1:4:8 type D-2 using 40mm graded stone aggregate as in foundation filling, and mass concrete complete all as specified and directed. |
| 44 | M&L for loose filling with broken bricks aggregate of gauge 80 to 150mm in soakage pits, soakage wells complete all as specified and directed. |
| 45 | M&L for loose filling with broken bricks aggregate of gauge 40 to 80mm in soakage pits, soakage wells complete all as specified and directed. |
| 46 | S&F for 100mm bore Cast iron soil, waste and vent pipes, in any length with or without ears, with cement joints, fixed to walls etc incl taking down old pipe complete all as specifed and dirtected. |
| 47 | S&F for 75mm bore Cast iron soil, waste and vent pipes, in any length with or without ears, with cement joints, fixed to walls etc complete incl taking down old pipe complete all as specifed and dirtected. |
| 48 | S&F for 100mm bore CI bends (any radius), diminishing pieces or tapers (larger bore measured) complete all as specifed and dirtected. |
| 49 | S&F 75mm bore CI bends (any radius), diminishing pieces or tapers (larger bore measured) complete all as specifed and dirtected. |
| 50 | S&F for 100mm branch pieces, single (equal or unequal), ordinary or inverted (spigot or socket type) or with parallel branches/ Tee etc complete all as specifed and dirtected. |
| 51 | S&F for 75mm branch pieces, single (equal or unequal), ordinary or inverted (spigot or socket type) or with parallel branches/ Tee etc complete all as specifed and dirtected. |
| 52 | S& F for 75 Cast Iron Cowl complete all as specifed and dirtected. |
| 53 | S& F for 100 Cast Iron Cowl complete all as specifed and dirtected. |
| 54 | S&F for 75mm dia of outlet cast iron floor trap, with grating including jointing to waste pipe fixed in cement concrete type B-1 (1:2:4) complete all as specifed and dirtected. |
| 55 | S&F for 100mm dia of outlet cast iron floor trap, with grating including jointing to waste pipe fixed in cement concrete type B-1 (1:2:4) complete all as specifed and dirtected. |
| 56 | S&F for 110mm bore PVC pipes single socketed Pressure rating @4Kg/Sq cm length \\"medium grade \\" with rubber ring joint, fixed to walls with dash ture nut and bolt at every 2 mtrs length complete , incl taking up/down old pipe with all fittings complete all as specified and directed. |
| 57 | All as per item No 56 above but laid in trench or in floor |
| 58 | S&F for 110mm bore PVC bends/junction any radius complete all as specified and directed. . |
| 59 | S&F for 110mm bore PVC bends/junction with access door any radius complete all as specified and directed. . |
| 60 | S&F for 75mm dia PVC (SWR) floor trap, plain with grating including jointing with solvent cement complete all as specified and directed. . |
| 61 | S&F for 75mm dia PVC (SWR) multi floor trap, plain with grating including jointing with solvent cement complete all as specified and directed. . |
| 62 | S&F for 75 mm bore PVC pipes single socketed Pressure rating @4Kg/Sq cm length \\"medium grade \\" with rubber ring joint, fixed to walls with dash ture nut and bolt at every 2 mtrs length complete , incl taking up/down old pipe with all fittings complete all as specified and directed. |
| 63 | S&F for 75 mm bore PVC bends/junction any radius complete all as specified and directed. . |
| 64 | S&F PVC (SWR) floor trap, plain with CP grating including jointing with solvent cement, 75mm diameter of outlet, complete all as specified and directed. |
| 65 | Removing daberies/excavated material to a distance exceeding 1.5KM but not exceeding 5 KM and depositing where directed at a level n. exc 1.50 m above the starting point complete all as specified and directed. |
| 66 | Taking down carefully copper/aluminium point wiring (light, fan, socket, bell or power) complete including all electrical fittings & fixtures(DBs, submain,cables etc) and making good disturbed surfaces of wall , floor etc and matching wth original colour of wall, complete all as specified and directed. |
| 67 | M&L for one light/fan/exhaust fan point wiring controlled by one switch with PVC insulated unsheathed multi stranded copper conductor (FRLS) of size 1.5 Sqmm (for Phase colour code Red and for Neutral colour code Black) and one run of size 1.5 Sqmm PVC insulated unsheathed multi stranded copper conductor (FRLS) (as earth wire, colour code green) and connected to common earth dolly all as specified. , drawn through in and in existing concealed / surface PVC Conduit/ saddle medium grade, ISI marked 20 mm dia along with conduit fixing accessories and with pressed steel terminal box thickness 1.6 mm painted with one coat of black bituminous paint as a primary and two coats of enamel paint with 3 mm thick laminated sheet (Make: Hylam) for provision of switches/regulators complete all as specified and directed.NOTE:-After rewiring cutting chasing portion should be matched with existing finishes of walls. |
| 68 | All as per item No 67 above but 5 Amp socket outlet, independent. |
| 69 | All as per item No 67 above but on the same board. |
| 70 | All as per item No 67 above but for one bell/Buzzer point controlled by one push button on the same board with other switches or independent with 1.50 sqmm size cable. |
| 71 | All as per item No 67 above but 2.5 sq mm wire for one 15 Amps socket outlet independent with continuous PVC insulated single core green colour copper earth wire of size 2.5 sq mm connected to common earth dolly. |
| 72 | Supply & fixing in replacement of switch piano type 5 amp SP one way ISI Marked complete all as specified and directed. |
| 73 | Supply & fixing in replacement of switch 15 Amps SP one way ISI Marked complete all as specified and directed. |
| 74 | Supply & fixing in replacement of socket outlet 3 pin 5 Amps flush type complete all as specified and directed. |
| 75 | Supply & fixing in replacement of socket outlet 2-in-1, 3 pin 5 amps and 15 amps flush type complete all as specified and directed. |
| 76 | Supply & fixing in replacement of stepped type electronic fan regulator flush type on the existing phenolic sheet etc complete all as specified and directed. |
| 77 | M&L for one light/fan/exhaust fan point wiring controlled by one switch with PVC insulated unsheathed multi stranded copper conductor (FRLS) of size 1.5 Sqmm (for Phase colour code Red and for Neutral colour code Black) and one run of size 1.5 Sqmm PVC insulated unsheathed multi stranded copper conductor (FRLS) (as earth wire, colour code green) and connected to common earth dolly all as specified. , drawn through PVC casing caping of ISI marked with fixing accessories and with pressed steel terminal box thickness 1.6 mm painted with one coat of black bituminous paint as a primary and two coats of enamel paint with 3 mm thick laminated sheet (Make: Hylam) for provision of switches/regulators complete all as specified and directed.NOTE:-After rewiring cutting chasing portion should be matched with existing finishes of walls. |
| 78 | All as per item No 77 above but 5 Amp socket outlet, independent. |
| 79 | All as per item No 77 above but on the same board. |
| 80 | All as per item No 77 above but 2.5 sq mm wire for one 15 Amps socket outlet independent with continuous PVC insulated single core green colour copper earth wire of size 2.5 sq mm connected to common earth dolly. |
| 81 | S&F in replacement for modular switches 6 amps single pole one waycomplete all as specified and directed. |
| 82 | S&F in replacement for modular sockets out let 6 amps 6 pin 2 module with shutter complete all as specified and directed. |
| 83 | S&F in replacement for modular switches 16 Amps single pole one way complete all as specified and directed. |
| 84 | S&Fin replacement modular socket out let 6-16 Amps 3 pin combined shuttered complete all as specified and directed. |
| 85 | Supply & fixing in replacement of stepped type electronic fan regulator modular complete all as specified and directed. |
| 86 | S&F in repair ceiling rose complete all as specified and directed. |
| 87 | Supply & fixing in replacement of ding dong bell electric 230 volt AC complete all as specified and directed. |
| 88 | S&F bell push, in repairs, flush type 5 Amps complete all as specified and directed. |
| 89 | S&F single pole blanking plate in the existing cover plate complete all as specified and directed. |
| 90 | Supply and fix modular white cover plate with frame 3 module ISI marked complete all as specified and as directed. |
| 91 | Supply and fix modular white cover plate with frame 4 module ISI marked complete all as specified and as directed. |
| 92 | Supply and fix modular white cover plate with frame 6 module ISI marked complete all as specified and as directed. |
| 93 | Supply and fix modular white cover plate with frame 8 module ISI marked complete all as specified and as directed. |
| 94 | Supply and fix modular metal flush box 3 module ISI marked complete all as specified and as directed. |
| 95 | Supply and fix modular metal flush box 4 module ISI marked complete all as specified and as directed. |
| 96 | Supply and fix modular metal flush box 6 module ISI marked complete all as specified and as directed. |
| 97 | Supply and fix modular metal flush box 8 module ISI marked complete all as specified and as directed. |
| 98 | Supply and fix flushed inside the wall MS sunken box more than 1mm thicknes of size 4\\"x4\\" complete all as specified and as directed. |
| 99 | Supply and fix flushed inside the wall MS sunken box more than 1mm thicknes of size 7\\"x4\\" complete all as specified and as directed. |
| 100 | Supply and fix flushed inside the wall MS sunken box more than 1mm thicknes of size 8\\"x10\\" complete all as specified and as directed. |
| 101 | Supply & fixing in replacement of SPN enclosure with two pin and earth plug and socket complete with on SP MCB 20 Amps complete all as specified and directed. |
| 102 | M&L PVC insulated FRLS single core with strandard copper cable of size 6 Sqmm in two run and 6 Sqmm one run for earth and drawing through existing concealed conduit including taking down old UNSV cable complete all as specified and directed.NOTE :- 2 runs of 6 Sqmm cable and one run of 6 sqmm cable will be measured as one running meter for the purpose of measurement and payment. |
| 103 | All as per item No 102 above but copper cable single core of size 4 Sqmm in two run with earth wire 4 Sqmm single run for continuity .NOTE :- 2 runs of 4 Sqmm cable and one run of 4 sqmm cable will be measured as one running meter for the purpose of measurement and payment. |
| 104 | All as per item No 102 above but copper cable single core of size 2.5 Sqmm in two run with earth wire 2.5 Sqmm single run for continuity.NOTE :- 2 runs of 2.5 Sqmm cable and one run of 2.5 sqmm cable will be measured as one running meter for the purpose of measurement and payment. |
| 105 | M&L PVC insulated FRLS single core with strandard copper cable of size 2.5 Sqmm in two run and 2.5 Sqmm one run for earth and drawing through ISI marked casing caping including taking down old UNSV cable complete all as specified and directed.NOTE :- 2 runs of 2.5 Sqmm cable and one run of 6 sqmm cable will be measured as one running meter for the purpose of measurement and payment. |
| 106 | Supply and fix in replacement post top lantern LED 40 W or next highest wattage having IP65 protction for single phase connection 50 Hz 230 Volts complete all as specified and directed. |
| 107 | Supply and fix in replacement LED bollard fitting 9 Watt with luminaire with MS Pipe housing with glare free PMMA diffuser , IP65 of height 800 mm suitable for single phase connection 50 Hz 230 Volts complete all as specified and directed. |
| 108 | M&L for Recess mounted 15 Watt high efficancy recess LED slim round downlighter IP20 with high brightness LED for glare free homogenous illumination celing light complete with electronic driver complete all as specified and directed. |
| 109 | S&F in replacement wall mounting box type LED tube light fitting , extruded aluminium heat sink provided for efficient heat dissipation & Integrated electronic driver 1x20 watt comprising of strong jointless CRCA body complete with all accessories and complete all as specified and directed. |
| 110 | M&L for Recess mounted 36/ 40 Watt high efficancy 2x2 recess LED flat panel with high brightness LED for glare free homogenous illumination celing light complete with electronic driver complete all as specified and directed. |
| 111 | Supply and Fixing LED street light fitting 60 Watt pressure die case aluminium housing LED street light luminaires suitable for existing street light pole including all fixing accessaries complete all as specified and directed. |
| 112 | Supply and fixing in replacement of old unsv GI bracket made out of 32 mm bore,light grade 1.2 m long bent to shape suitable for street light fitting including MS flat clamp 50 x 6 mm 2 Nos for each bracket with nut & bolt complete all as specified and directed. |
| 113 | Supply and laying or fixing or passing through pipe, 1100 volts grade heavy duty cable with PVC insulated aluminium conductor served with an inner sheathing of PVC tape with galvanised steel wire or tape and overall PVC sheathed 2 core 6 sq. mm nominal cross section in service connections complete all as specified and directed. |
| 114 | S&F sheet metal enclosures DB Double door Verticle distribution type, 04 way, TPN DB , IP43, 415V & suitable for 4 POLE MCCB as incomming including shruded neutral bar & Pan assy with earthing terminal as provided by manufacturer complete all as specified and directed.Note : - MCCB shall be measured and paid separately |
| 115 | S&F sheet metal enclosures DB Double door Verticle distribution type, 06 way, TPN DB , IP43, 415V & suitable for 4 POLE MCCB as incomming including shruded neutral bar & Pan assy with earthing terminal as provided by manufacturer complete all as specified and directed.Note : - MCCB shall be measured and paid separately |
| 116 | S&F in replacement MCB DB TPN 4 Way factory made IP 42 protection class metal double door with 200 Amp rating bus bar 240 for fixing of MCBs/Isolators/RCCBs etc complete all as specified and directed. |
| 117 | S&F in replacement MCB DB SPN 4 Way factory made IP 42 protection class metal double door with 200 Amp rating bus bar 240 for fixing of MCBs/Isolators/RCCBs etc complete all as specified and directed. |
| 118 | S&F in replacement MCB DB SPN 6 Way factory made IP 42 protection class metal double door with 200 Amp rating bus bar 240 for fixing of MCBs/Isolators/RCCBs etc complete all as specified and directed. |
| 119 | S&F in replacement MCB DB SPN 8 Way factory made IP 42 protection class metal double door with 200 Amp rating bus bar 240 for fixing of MCBs/Isolators/RCCBs etc complete all as specified and directed. |
| 120 | S&F in replacement MCB DB SPN 12 Way factory made IP 42 protection class metal double door with 200 Amp rating bus bar 240 for fixing of MCBs/Isolators/RCCBs etc complete all as specified and directed. |
| 121 | Supply & fixing in replacement of MCCB TPN 63Amps 16KA complete all as specified and directed. |
| 122 | S&F in replacement of MCCB TPN 125 Amps 415 Volts 16 KA as per suitable sample of size complete all as specified and directed. |
| 123 | S&F in replacement of MCCB TPN 100 Amps 415 Volts 16 KA as per suitable sample of size complete all as specified and directed. |
| 124 | S&F in repairs MCB SP 6 to 32 Amps 240 Volts.\\"B\\" grade complete all as specified and directed. |
| 125 | S&F in repairs MCB,SP 40 Amps, 240 Volts.\\"B\\" grade complete all as specified and directed. |
| 126 | S&F in repairs MCB SPN, 40 Amps, 240Volts .\\"B\\" grade complete all as specified and directed. |
| 127 | S&F in repairs MCB SPN, 63 Amps, 240Volts.\\"B\\" grade complete all as specified and directed. |
| 128 | S&F in repairs MCB TPN, 63 to 100 Amps,415Volts .\\"B\\" grade complete all as specified and directed. |
| 129 | Supplying and fixing PVC conduit 25 MM dia along with accessories in surface/recess I/C or cutting the wall and making good the same in case of recessed conduit as required complete all as specified and directed. |
| 130 | S&F in replacement of Casing capping double lock type supper quality size 15 mm width ISI marked with fixing accessories complete all as specified and directed. |
| 131 | Supply and fix modular type gang box(3 module for one socket and one switche) suitable for 5/15amp 6pin including plate cover plastic sunken box etc including suitable size of switches and sockets as per complete all as specified and directed. |
| 132 | Taking down ceiling fan complete any type size from existing location and cleaning body blades etc including servicing, greasing,oiling,replacing wornout bearing ,bush and refixing the same at site complete all as specified and directed. |
| 133 | All as per item No 132 above but for Exhaust fan complete. |
| 134 | All as per item No 132 above but for wall/floor mounted fan . |
| 135 | M&L for rewinding unserviceable ceiling fan 1200/1400 mm Sweep from site by strip opening,cutting removing the burnt winding from starter cleaning the slots and rewind the same with original guage of super enameled copper winding wire, insulation materials and all accessories & varnishing etc replacement of service wire copper twisted size 23/0.0076 including reassembling the fan complete all as specified and directed. |
| 136 | All as per item No 135 above but for Exhaust fan 300 mm sweep complete |
| 137 | All as per item No 135 here in above but for wall/floor mounted fan 450 mm sweep. |
| 138 | M&L Painting of ceiling fans complete, in situ with synthetic enamel paint by spraying including filling cavities with filler, one coat after cleaning all dust etc complete all as specified and directed. |
| 139 | M&L for Replacement of old unserviceable fan blades, (ISI Marked), suitable for 1200mm sweep ceiling fan duly painted in white/brown by using spray gun method(fully furnished) complete all as specified and directed. |
| 140 | M&L for Repalcement of old unserviceable down rod of ceiling fan of dia 20mm bore \\"medium grade\\" complete with split pin, hanging clamp and rubber real (length of rod not less than 45cm and not more than 60cm) dully painted in white/brown by using spray gun method (fully furnished) complete all as specified and directed. |
| 141 | S&F cable PVC insulated and overall sheathed with flexible copper conductor cable of size 0.5 sqmm,3 core cut to size of approx 0.30 metre from block of fan to ceiling rose complete all as specified and directed. |
| 142 | M&L for replacement of old unserviceable gun metal bush of ceiling fan including neceassry laith, Grinding and welding work complete all as specified and directed. |
| 143 | M&L for replacement of old unserviceable shackle assembly kit (Rubber real -01, MS split clamp two Nos, nuts and bolts washers- 2 Nos & split pin -02 Nos) suitable for ceiling fan of 1200/1400mm sweep complete all as specified and directed. |
| 144 | M&L for Replacement of old unserviceable steel screw of size 5mm to 8mm (to be used for fixing of fan blade) complete all as specified and directed. |
| 145 | S&F ceiling fans complete with blades, down rods and accessories, 230 V, 1200 mm sweep. Min air delivery 210 CFM with service value 6.00 BEE. Five star rated with brushless direct current motor (BLDC) with remote control complete all as specified and directed. |
| 146 | S&F in replacement of exhaust fan heady duty metal body 300 mm sweep including necessary fixing arrangement for proper fixing in wall and making hole as per site requirement complete all as specified and directed. |
| 147 | S&F in replacement of exhaust fan heady duty metal body type 250 mm sweep including necessary fixing arrangement for proper fixing in wall and making hole as per site requirement complete all as specified and directed. |
| 148 | S&F in replacement of exhaust fan heavy duty plastic body 250 mm sweep including necessary fixing arrangement for proper fixing in wall and making hole as per site requirement complete all as specified and directed. |
| 149 | S&F in replacement of wall mounting fan heady duty 400 mm sweep including necessary fixing arrangement for proper fixing on wall as per site requirement complete all as specified and directed. |
| 150 | M&L for replacement of old unserviceable capacitor AC 400/415 volts 2.5 mfd (ISI marked) complete all as specified and directed. |
| 151 | M&L for replacement of old unserviceable capacitor AC 400/415 volts 3.15 mfd (ISI marked) complete all as specified and directed. Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Tender Published
Tender notice published.
CompletedCorrigendum-1 Issued
Clarifications on tender conditions and amendments issued.
TodayBid Submission Deadline
Online submission via eProcurement portal.
TodayBid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 2 daysTender Documents
Download All (ZIP) ↓We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender