Defence Statutory Bodies & Commissions/Committees Closing in 0 days TDR #56671319

Tender For Repair/Replacement To Floor, Sanitary Fittings, Plumbing Fitting , Improvement In Fence And Wall And Certain Misc And Elect Work, Dad Residential Colony Lekhanagar Under The Area Of Age B/R-I At Ge (W) Bareilly

Issued by Statutory Bodies & Commissions/Committees · Bareilly, Uttar Pradesh
Tender Value
36.12 Lakhs
Estimated cost
Bid Submission
24 Aug 2026
0 days left
EMD
72500
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Bareilly → Uttar Pradesh
EMD Exemption
Available
Quantity
Not Available

Project Description

Tender for Repair/Replacement To Floor, Sanitary Fittings, Plumbing Fitting , Improvement In Fence And Wall And Certain Misc And Elect Work, Dad Residential Colony Lekhanagar Under The Area Of Age B/R-I At Ge (W) Bareilly

Corrigendum

Sr No Corrigendum Date Corrigendum Type New Submission Date
1 17-Aug-2026 Bid Auto Extn Corrigendum Bid Auto Extn Corrigendum 24-Aug-2026

BOQ

Name of Work:- Repair/Replacement to floor, sanitary fittings, plumbing fitting , improvement in fence and wall and certain misc and elect work, DAD residential colony lekhanagar under the area of AGE B/R-I at GE (W) Bareilly
Sl. No. Item Description
1M&L for Machine pressed precast coloured rubber moulded glazed finished conctete interlocking paver block with gray cement and pigment any shape and size confirming to IS 15658-2006 of 60 mm thickness M-40 Grade over and including M&L for 25mm thick sand cushioning including watering and consolidation and necessary demoliton of existing surface complete all specified and directed.
2M&L for 75mm thick Cement concrete type D- 2, 1:4:8 (40mm graded aggregate) as sub base of floor or hardstanding including necessary demoliton complete all as specified and directed.
3M&L providing cement concrete 1:2:4 type B1 (using 20 mm graded stone aggregate) as in benching, coping, bed blocks including necessary form work, weathering slightly rounded or chamfered angles and throating, complete all as specified and directed.
4Excavation in Post holes (or similar holes ) in any type of soil, each not exe 0.5 cum , getting out , returning filling and ramming carts not exc 25cm , watering and removing surplus soil to a distance not exc 50 mtr and making good surface complete
5Dismantling posts and struts(wood, steel or rcc) any section, including taking out embedded portion in concrete and making good disturbed ground complete all as specified and directed.
6S&F posts and struts in fencing including cutting tops to shape as directed, drilling holes, notching for wire, wind ties, etc.; flat iron fillets ( for securing wire mesh etc.) including all necessary drilling, bolting or riveting, etc., and similar work conforming to Fe 290 Gde E-165 complete all as directed.
7S & F MS Galvanised Chain Link Fencing including line wires any mesh, size and type to any type of standards, rails, straining bolt, etc including provision of binding wire complete all as spd and directed.
8MS screw bolts with hexagonal or square heads at one end and screwed the other, or screwed both ends,each screwed end to be fitted with washers and one hexagonal or square nut n exc 5cm long 10 mm dia of bolts and nuts
9M&L applying two coats of synthetic enamel paint over a coat of red oxide or zinc chrome primer including preparation of new steel or iron surfaces exc 10 cm width or girth, complete all as specified and directed.
10M&L for Glazed finished in vertical surface min size 450mmx350mmx7mm thick on vertical faces of walls and including 10mm thick rendeing in CM 1:4 set jointed in neat cement slurry and pointed in coloured cement to match including taking down old dado/skirting etc complete all as specified.
11M & L for non- skid ceremic coloured tiles 7mm to 8 mm thick (Square / rectangular) area of each tile exceeding 0.11 Sqm but not exceeding 0.18 Sqm in floors etc set and jointed in neat cement slurry and pointed in white or coloured cement to match including dismantling of tiles and including M&L for screed bed or bedding layer of mortar 15mm thick in cement mortar 1:6 for laying floor finishes all as specified.
12M&L for Vitrified coloured ceramic tiles light shade 8mm-10mm thick (square/rectangular) polished, area of each tiles exc 0.18 sqm and not exc 0.38 sqm in floor etc, set and jointed in neat cement slurry and pointed in white or coloured cement and with including M&L for 15mm thick screed bed 1:6 cement motar including dismantling of floor tiles and hearting complete all as specified and directed.
13M&L Preparation of old wooden surfaces of any description, not otherwise described over 10cm width or girth and applying one coat of synthetic enamel paint complete all as spd and directed.
14M & L preparation of old steel surfaces of any description over 10 cm in width or girth and applying one coat of synthetic enamel paint complete all as spd and directed.
15Taking down cemet plaster of any description complete all as specified and directed
16M&L 15mm thick cement plaster on brick surfaces or concrete surfaces (on external surface) in cm (1:4) using of cement finishing the surface even and smooth without using extra cement and necessary scaffolding upto height of 7m all as spd and directed.
17M&L 12mm thick cement plaster on other than fair faces of brick surfaces or concrete surfaces (on internal surface) in cm (1:6) plaster finishing the surface even and smooth without using extra cement and necessary scaffolding upto height of 7m all as spd and directed
18M & L for rendering 5mm thick on ceiling or concrete surfaces in cement mortar (1:3) finished plaster the surface even and smooth without using extra cement and necessary scaffolding complete all as spd and directed
19Demolition of brick work or stone/boulder masonry built in cement mortar or cement lime mortar including all quoins, aches, pillars etc but excluding ashlar facing dressed stone work and precast concrete articles all as spd and directed
20M&L Brickwork old size with subclass ‘B’ brick straight or curved on plan exc 6m mean radius built in in CM (1:6) all as spd and directed
21M&L Brickwork old size with subclass ‘B’ bricks, except brick straight or curved on plan exc 6m mean radius built in in CM (1:6) all as spd and directed
22Demolition of cement concrete (un-reinforced), in any position and paving n.exc.15 cm thickness( below or above ground level) including tile/ terrazzo floor complete all as specified and directed.
23M&L for PCC 1:4:8 type D-2 using 40mm graded stone aggregate for surface channels, bed of drains incl forms/ moulds etc. complete all as specified and directed.
24M&L Extra for forming fair finished to drain or channel, 30 cm inner girth or above , in cement concrete, using extra cement, including forms, moulds, mitred / stopped ends etc complete all as specified and directed.
25M&L white washing three coats on ceiling surfaces including preparation of newly plastered untreated surfaces and necessary scaffolding all as spd and directed
26M&L for applying 1.5 mm thick layer of wall care putty on external and internal wall surfaces including rubbing down the surfaces with sand paper after getting dried all as directed to obtain a smooth & even surface complete all as spd and directed.
27M&L Preparation of old decorated surfaces and applying two coat of white wash on ceilings surfaces and complete removal including rubbing down with sand paper to have even and smooth surfaces all as specified & directed.
28M&L for complete removal of existing treatment on wall by scrapping with mechanical sander (having mechanical vaccum mechanism ) with sanding pad of appropriate grit to make surface clean ,free from dust ,loose paint etc by skilled labour and applying two coat OBD on wall and including M&L for one coat of cement putty of 1mm thickness complete all as specified and directed.
29M&L for two coat OBD on newly plastered wall surface over a coat of primer over one coat of cement putty of 1.5 mm thickness complete all as specified and directed.
30M & L applying two coat of cement based paint on old decorated or undecorated wall, roof surface including preparation of surfaces by washing rubbing down and stoping of distempered and painted surfaces complete all as specified.
31M&L two coats of cement base paint on new plastered wall surfaces over a coat of primer of any description including preparation of surfaces, complete all as specified
32M & L for cutting chases of hanging chajjas, pinning in, making good to facings where required and pointing in cement mortar 1:3 to ends or edges of sunshades, shelves, lintels, Chajja ( up to IIIrd floor) etc making good, cutting out exc 10cm and not exc 40cm girth in RCC chajjas in brick walls complete all as specified and as directed.
33S&F for 15mm bore GI water tubing with all fittings 'medium grade' and fixed complete to wall and ceiling or laid in floors incl taking down of existing pipe line of any description complete all as specified or as directed.
34S&F for 20mm bore GI water tubing with all fittings 'medium grade' and fixed complete to wall and ceiling or laid in floors incl taking down of existing pipe line of any description complete all as specified or as directed.
35S&F in repair stainles steel Curtain Rod 25 mm dia of approved quality with two number decorative design as approved brackets fixed in brick/concrete wall and same finished knobs on each end of curtain rod all as directed and specified.
36S & F 1000 ltrs capacity rotational moulded polythylene triple layered water storage tanks white in colour (cylindrical vertical with closed top) hoisted and fixed in position incl dismalting of existing tank/ demolition of RCC water storage tank of capacity and any description all as specified in SSR Part I complete all as specified and directed.
37M&L for cleaning of water tank capacity exe 500 Ltrs and n exc 1000Ltr and removing all scale and dirt, etc, from tanks and from mouths of circulating pipes and restored internal water supply, etc complete all as specified and as directed.
38S&F sheet glass 4.00mm thick ordinary quality and glazing with oil putty/necessary beading in square n exc 0.5 Sqm each pane including hacking out of old broken glasses complete all as spd & directed
39S& F in repair Galvanised mild steel wire cloth, 0.63mm nominal dia of wire and average width of aperture 1.40mm and fixed with tinned tacks, or galvanised wire staples complete all as spd & directed
40S&F in repair PVC waste pipe for wash basin & sink etc with complete all as specified.
41S&F in repair 15mm bore ball valves high pressure of PTMT with epoxy coated aluminium rod & high-density plastic ball screwed for iron pipe and fixed (Minimum weight 210 gms complete all as specified or as directed.
42S&F in repair of 20mm dia Gun-metal, globe or gate valves, with iron wheel head, screwed both ends for iron pipe and fixed
43Taking up or down AC/PVC rain water pipe, soil/waste/vent pipe of any size with fittings etc.
44S & F PVC (SWR) 110 mm dia soil waste or rainwater drainage pipes single socketed in any length with rubber ring joint laid in floor or fixed on wall all as specified or as directed.
45S & F in repair PVC (SWR) 110 mm bore bends all as specified or as directed.
46S&F PVC (SWR) 75 mm bore pipes single socketed in any length with rubber ring joints laid in floor or fixed on wall with necessary fitting complete all as specified and as directed.
47S&F in repair PVC 110mm bore Y-Junction piece single (equal or unequal) ordinary or inverted (spigot or shocket type) or with parallel branches with oval access door
48S&F in repair PVC 110mm bore branch piece single (equal or unequal) ordinary or inverted (spigot or shocket type) or with parallel branches.
49S&F in repair PVC 75 mm bore branch piece single (equal or unequal) ordinary or inverted (spigot or shocket type) or with parallel branches.
50S&F in repair 110mm bore PVC bends (any radius) diminishing pieces or tapers (larger bore mesured) with oval access door
51S&F in repair 75mm bore PVC bends (any radius) diminishing pieces or tapers (larger bore mesured) with oval access door
52S&F in repairs for Stack clamps out of 50 mm by 5 mm flat iron and 16mm dia round iron stays for up 110mm dia pipe, including bolts and nuts and securing ends of stays to wall or roof complete all as specified and directed.
53M & L for cutting into existing manhole for connecting new drains, making good to pipe and rendering, cutting out existing benching for and forming branch channel (1/2 round or ¾ section) in cement concrete 1:2:4 type B-1 (using 20mm graded stone aggregate complete all as specified and directed.
54Excavating in trenches, n exc 1.5m wide & n exc 1.5m in depth; for foundation etc. or for shafts,cesspits, manholes, pier holes, etc. n exc 10sq m on plan & getting out in soft/loose soil complete as specified
55Returning filling in, including spreading, leveling, watering and well ramming in layers n.exc 25 CM in hard/dense soil.
56Removing excavated soil exc 250m but n exc. 500m & depositing where directed at a level n exc. 1.5 m above the starting point
57M&L for 150 mm dia Sail-glazed stoneware drain pipes laid in trenches and jointed as specified, in plain Cement concrete 1:3:6 type C-1 (using 20 mm graded stone aggregate) including packing under, and haunching against the sides of pipes after they are laid and tested including dismantling of existing pipe and pcc etc complete complete all as specified and directed. Please Enable Macros to View BoQ information
58M&L for 150 mm dia Sail-glazed stoneware drain pipes laid in trenches and jointed as specified, in plain Cement concrete 1:3:6 type C-1 (using 20 mm graded stone aggregate) including packing under, and haunching against the sides of pipes after they are laid and tested including dismantling of existing pipe and pcc etc complete complete all as specified and directed. Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 56671319
AUTHORITY Statutory Bodies & Commissions/Committees
TENDER VALUE 36.12 Lakhs
LAST DATE 24-08-2026
Authority
Authority Name Military Engineer Services
Work Description Tender for Repair/Replacement To Floor, Sanitary Fittings, Plumbing Fitting , Improvement In Fence And Wall And Certain Misc And Elect Work, Dad Residential Colony Lekhanagar Under The Area Of Age B/R-I At Ge (W) Bareilly
Basic Detail
Tender No 8406/C/E8
Bidding Type Tender
Location
City Bareilly
State Uttar Pradesh
Key Dates
Publish Date 17 Aug 2026
Submission Date 24 Aug 2026
Open Date 26 Aug 2026
Finance
Tender Value 36.12 Lakhs
Tender Fee 500
EMD 72500
Exemption Available
Document List
BOQ_874748.xls
COMPLETETENDER8406.pdf
f9386551-1e11-4c11-bcb3-27b2f8f4146c.html
Tendernotice_1.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Aug 17, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Aug 24, 2026
18:00 IST

Corrigendum-1 Issued

Clarifications on tender conditions and amendments issued.

Today
Aug 24, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Today
Aug 26, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 2 days

Tender Documents

Download All (ZIP) ↓
xls

BOQ_874748.xls

pdf

COMPLETETENDER8406.pdf

html

f9386551-1e11-4c11-bcb3-27b2f8f4146c.html

pdf

Tendernotice_1.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail
Loading tenders