Tender For Repair/Replacement/Maint Of Internal Electrification, Fitting, Fixtures, Earthing, Various Capacity Lt Switch Gear, Apfc Panels, Security/Flood Lights, Summer Appliances , Hot Water Appliances, Acs And Other E/M Items At Af Stn 3 Wing Unde
Tender Overview
Project Description
Tender for Repair/Replacement/Maint Of Internal Electrification, Fitting, Fixtures, Earthing, Various Capacity Lt Switch Gear, Apfc Panels, Security/Flood Lights, Summer Appliances , Hot Water Appliances, Acs And Other E/M Items At Af Stn 3 Wing Under Aor Of Ge (Af) Faridabad
BOQ
| Sl. No. | Item Description |
| 1 | Taking down carefully copper/aluminium point wiring (light, fan, socket, bell or power) complete including all electrical fittings & fixtures(DBs, submain,cables etc) and making good disturbed surfaces of wall , floor etc and matching wth original colour of wall, complete all as specified and directed. |
| 2 | M&L for one light/fan/exhaust fan point wiring controlled by one switch with PVC insulated unsheathed multi stranded copper conductor (FRLS) of size 1.5 Sqmm (for Phase colour code Red and for Neutral colour code Black) and one run of size 1.5 Sqmm PVC insulated unsheathed multi stranded copper conductor (FRLS) (as earth wire, colour code green) and connected to common earth dolly all as specified. , drawn through in and in existing concealed / surface PVC Conduit/ saddle medium grade, ISI marked 20 mm dia along with conduit fixing accessories and with pressed steel terminal box thickness 1.6 mm painted with one coat of black bituminous paint as a primary and two coats of enamel paint with 3 mm thick laminated sheet (Make: Hylam) for provision of switches/regulators complete all as specified and directed.Note :- After rewiring cutting chasing portion should be matched with existing finishes of walls. |
| 3 | All as per item No 2 above but 5 Amp socket outlet, independent. |
| 4 | All as per item No 2 above but on the same board. |
| 5 | All as per item No 2 above but for one bell/Buzzer point controlled by one push button on the same board with other switches or independent with 1.50 sqmm size cable. |
| 6 | All as per item No 2 above but 2.5 sq mm wire for one 15 Amps socket outlet independent with continuous PVC insulated single core green colour copper earth wire of size 2.5 sq mm connected to common earth dolly. |
| 7 | S&F in replacement of switch piano type 5 amp SP one way ISI Marked complete all as specified and directed. |
| 8 | S&F in replacement of switch 15 Amps SP one way ISI Marked complete all as specified and directed. |
| 9 | S&F in replacement of socket outlet 3 pin 5 Amps flush type complete all as specified and directed. |
| 10 | S&F in replacement of socket outlet 2-in-1, 3 pin 5 amps and 15 amps flush type complete all as specified and directed. |
| 11 | S&F in replacement of stepped type electronic fan regulator flush type on the existing phenolic sheet etc complete all as specified and directed. |
| 12 | M&L for one light/fan/exhaust fan point wiring controlled by one switch with PVC insulated unsheathed multi stranded copper conductor (FRLS) of size 1.5 Sqmm (for Phase colour code Red and for Neutral colour code Black) and one run of size 1.5 Sqmm PVC insulated unsheathed multi stranded copper conductor (FRLS) (as earth wire, colour code green) and connected to common earth dolly all as specified. , drawn through PVC casing caping of ISI marked with fixing accessories and with pressed steel terminal box thickness 1.6 mm painted with one coat of black bituminous paint as a primary and two coats of enamel paint with 3 mm thick laminated sheet (Make: Hylam) for provision of switches/regulators complete all as specified and directed.Note :- After rewiring cutting chasing portion should be matched with existing finishes of walls. |
| 13 | All as per item No 12 above but 5 Amp socket outlet, independent. |
| 14 | All as per item No 12 above but on the same board. |
| 15 | All as per item No 12 above but 2.5 sq mm wire for one 15 Amps socket outlet independent with continuous PVC insulated single core green colour copper earth wire of size 2.5 sq mm connected to common earth dolly. |
| 16 | S&F in replacement for modular switches 6 amps single pole one way complete all as specified and directed. |
| 17 | S&F in replacement for modular sockets out let 6 amps 6 pin 2 module with shutter complete all as specified and directed. |
| 18 | S&F in replacement for modular switches 16 Amps single pole one way complete all as specified and directed. |
| 19 | S&F in replacement modular socket out let 6-16 Amps 3 pin combined shuttered complete all as specified and directed. |
| 20 | S&F in replacement of stepped type electronic fan regulator modular complete all as specified and directed. |
| 21 | S&F in repair ceiling rose complete all as specified and directed. |
| 22 | S&F in replacement of ding dong bell electric 230 volt AC complete all as specified and directed. |
| 23 | S&F bell push, in repairs, flush type 5 Amps complete all as specified and directed. |
| 24 | S&F single pole blanking plate in the existing cover plate complete all as specified and directed. |
| 25 | S&F modular white cover plate with frame 3 module ISI marked complete all as specified and directed. |
| 26 | S&F modular white cover plate with frame 4 module ISI marked complete all as specified and as directed. |
| 27 | S&F modular white cover plate with frame 6 module ISI marked complete all as specified and as directed. |
| 28 | S&F modular white cover plate with frame 8 module ISI marked complete all as specified and as directed. |
| 29 | S&F modular metal flush box 3 module ISI marked complete all as specified and as directed. |
| 30 | S&F modular metal flush box 4 module ISI marked complete all as specified and as directed. |
| 31 | S&F modular metal flush box 6 module ISI marked complete all as specified and as directed. |
| 32 | S&F modular metal flush box 8 module ISI marked complete all as specified and as directed. |
| 33 | S&F flushed inside the wall MS sunken box more than 1mm thicknes of size 4\\"x4\\" complete all as specified and as directed. |
| 34 | S&F flushed inside the wall MS sunken box more than 1mm thicknes of size 7\\"x4\\" complete all as specified and as directed. |
| 35 | S&F flushed inside the wall MS sunken box more than 1mm thicknes of size 8\\"x10\\" complete all as specified and as directed. |
| 36 | S&F in replacement of SPN enclosure with two pin and earth plug and socket complete with on SP MCB 20 Amps complete all as specified and as directed. |
| 37 | M&L PVC insulated FRLS single core with strandard copper cable of size 6 Sqmm in two run and 6 Sqmm one run for earth and drawing through existing concealed conduit including taking down old UNSV cable complete all as specified and as directed.Note :- 2 runs of 6 Sqmm cable and one run of 6 sqmm cable will be measured as one running meter for the purpose of measurement and payment. |
| 38 | All as per item No 37 above but copper cable single core of size 4 Sqmm in two run with earth wire 4 Sqmm single run for continuity. Note :- 2 runs of 4 Sqmm cable and one run of 4 sqmm cable will be measured as one running meter for the purpose of measurement and payment. |
| 39 | All as per item No 37 above but copper cable single core of size 2.5 Sqmm in two run with earth wire 2.5 Sqmm single run for continuity. Note :- 2 runs of 2.5 Sqmm cable and one run of 2.5 sqmm cable will be measured as one running meter for the purpose of measurement and payment. |
| 40 | M&L PVC insulated FRLS single core with strandard copper cable of size 2.5 Sqmm in two run and 2.5 Sqmm one run for earth and drawing through ISI marked casing caping including taking down old UNSV cable.Note :- 2 runs of 2.5 Sqmm cable and one run of 6 sqmm cable will be measured as one running meter for the purpose of measurement and payment. |
| 41 | S&F in replacement post top lantern LED 40 W or next highest wattage having IP65 protction for single phase connection 50 Hz 230 Volts complete all as specified and as directed. |
| 42 | S&F in replacement LED bollard fitting 9 Watt with luminaire with MS Pipe housing with glare free PMMA diffuser , IP65 of height 900 mm suitable for single phase connection 50 Hz 230 Volts complete all as specified and as directed. |
| 43 | M&L for Recess mounted 15 Watt high efficancy recess LED slim round downlighter IP20 with high brightness LED for glare free homogenous illumination celing light complete with electronic driver complete all as specified and as directed. |
| 44 | S&F in replacement wall mounting box type LED tube light fitting , extruded aluminium heat sink provided for efficient heat dissipation & Integrated electronic driver 1x20 watt comprising of strong jointless CRCA body complete with all accessories and complete all as specified and as directed. |
| 45 | M&L for Recess mounted 36/ 40 Watt high efficancy 2x2 recess LED flat panel with high brightness LED for glare free homogenous illumination celing light complete with electronic driver complete all as specified and as directed. |
| 46 | S&F LED street light fitting 60 Watt pressure die case aluminium housing LED street light luminaires suitable for existing street light pole including all fixing accessaries complete all as specified and as directed. |
| 47 | S&F in replacement of old unsv GI bracket made out of 32 mm bore,light grade 1.2 m long bent to shape suitable for street light fitting including MS flat clamp 50 x 6 mm 2 Nos for each bracket with nut & bolt complete all as specified and as directed. |
| 48 | Supply and laying or fixing or passing through pipe, 1100 volts grade heavy duty cable with PVC insulated aluminium conductor served with an inner sheathing of PVC tape with galvanised steel wire or tape and overall PVC sheathed 2 core 6 sq. mm nominal cross section in service connections complete all as specified and as directed. |
| 49 | S&F sheet metal enclosures DB Double door Verticle distribution type, 04 way, TPN DB , IP43, 415V & suitable for 4 POLE MCCB as incomming including shruded neutral bar & Pan assy with earthing terminal as provided by manufacturer complete all as specified and as directed.Note : - MCCB shall be measured and paid separately |
| 50 | S&F sheet metal enclosures DB Double door Verticle distribution type, 06 way, TPN DB , IP43, 415V & suitable for 4 POLE MCCB as incomming including shruded neutral bar & Pan assy with earthing terminal as provided by manufacturer complete all as specified and as directed.Note : - MCCB shall be measured and paid separately |
| 51 | S&F in replacement MCB DB TPN 4 Way factory made IP 42 protection class metal double door with 200 Amp rating bus bar 240 for fixing of MCBs/Isolators/RCCBs etc complete all as specified and as directed. |
| 52 | S&F in replacement MCB DB SPN 4 Way factory made IP 42 protection class metal double door with 200 Amp rating bus bar 240 for fixing of MCBs/Isolators/RCCBs etc complete all as specified and as directed. |
| 53 | S&F in replacement MCB DB SPN 6 Way factory made IP 42 protection class metal double door with 200 Amp rating bus bar 240 for fixing of MCBs/Isolators/RCCBs etc complete all as specified and as directed. |
| 54 | S&F in replacement MCB DB SPN 8 Way factory made IP 42 protection class metal double door with 200 Amp rating bus bar 240 for fixing of MCBs/Isolators/RCCBs etc complete all as specified and as directed. |
| 55 | S&F in replacement MCB DB SPN 12 Way factory made IP 42 protection class metal double door with 200 Amp rating bus bar 240 for fixing of MCBs/Isolators/RCCBs etc complete all as specified and as directed. |
| 56 | S&F in replacement of MCCB TPN 63Amps 16KA complete all as specified and directed by Engineer-in-Charge. |
| 57 | S&F in replacement of MCCB TPN 125 Amps 415 Volts 16 KA as per suitable sample of size complete all as specified and as directed. |
| 58 | S&F in repairs MCB SP 6 to 32 Amps 240 Volts.\\"B\\" grade complete all as specified and as directed. |
| 59 | S&F in repairs MCB,SP 40 Amps, 240 Volts.\\"B\\" grade complete all as specified and as directed. |
| 60 | S&F in repairs MCB SPN, 40 Amps, 240Volts .\\"B\\" grade complete all as specified and as directed. |
| 61 | S&F in repairs MCB SPN, 63 Amps, 240Volts.\\"B\\" grade complete all as specified and directed. |
| 62 | S&F in repairs MCB TPN, 63 to 100 Amps,415Volts .\\"B\\" grade complete all as specified and directed. |
| 63 | S&F PVC conduit 25 MM dia along with accessories in surface/recess I/C or cutting the wall and making good the same in case of recessed conduit as required complete all as specified and as directed. |
| 64 | S&F in replacement of Casing capping double lock type supper quality size 15 mm width ISI marked with fixing accessories complete all as specified and as directed. |
| 65 | S&F modular type gang box(3 module for one socket and one switche) suitable for 5/15amp 6pin including plate cover plastic sunken box etc including suitable size of switches and sockets complete all as specified and as directed. |
| 66 | Excavation in trenches in soft/loose soil not exceeding 1.5 Mtr wide and not exceeding 1.5 Mtr depth for laying of cables/poles or foundation etc and getting out complete all as specified and as directed. |
| 67 | Add to item No 66 for each additional 1.5 mtr or part their of in depth beyond the first 1.5 mtr. |
| 68 | Returning, filling, including spreading levelling and well ramming in layers not exceeding 25cm apart complete all as specified and as directed. |
| 69 | Removing of surplus excavated soil to a distance not exceeding 50 Mtr from starting point and depositing where directed at a level not exceeding 1.5 Mtr above the starting point complete all as specified and as directed. |
| 70 | M&L for sand cushoning with a layer of sand 80mm thick before laying of cable and 150mm thick after laying of cable and punned down 100mm to trenches complete all as specified and as directed. |
| 71 | M&L for reinforced precast concrete cable cover, bricks for cable protection Class LV, Type I, flat, size 250mm x 150mm x 40mm complete all as specified and as directed. |
| 72 | Taking down/ out XLPE PVC insulated LT cable 1100 Volts grade from loose / hard soil / of any size complete all as specified and as directed. |
| 73 | Supplying, laying and testing XLPE cable, insulated screened PVC bedded galvanised steel strip or wire armoured LT 1100 volts grade (Heavy Duty) with stranded aluminium conducotr of cross secional area 16 Sqmm 4 core complete all as specified and as directed. |
| 74 | All as per item No 73 above but cross secional area 25 Sqmm 4 core. |
| 75 | All as per item No 73 above but cross secional area 50 Sqmm 3.5 core. |
| 76 | All as per item No 73 above but cross secional area 70 Sqmm 3.5 core. |
| 77 | All as per item No 73 but cross secional area 95 Sqmm 3.5 core. |
| 78 | Supply and laying or fixing or passing through pipe, 1100 volts grade heavy duty cable with PVC insulated aluminium conductor served with an inner sheathing of PVC tape with galvanised steel wire or tape and overall PVC sheathed 2 core 6 sq. mm nominal cross section in service connections complete all as specified and as directed. |
| 79 | M&L for 40mm dia of light grade GI pipe laid under road/floor/on pole for laying/fixing of cable complete all as specified and as directed. |
| 80 | S&F cable jointing kit for 1.1 KV grade cable for straight through joint complete with Jointing material heat Shrink type and accessories suitable for 3 ½ XLPE, armoured, Al conductor cable of size 10 to 25 sqmm,Outdoor type complete all as specified and as directed. |
| 81 | S&F cable jointing kit for 1.1 KV grade cable for straight through joint complete with Jointing material heat Shrink type and accessories suitable for 3 ½ XLPE, armoured, Al conductor cable of size 40 to 70 sqmm,Outdoor type complete all as specified and as directed. |
| 82 | M&L danger notice plate of 1.6mm thick mild steel sheet, vitreous enamelled white, with letters figures and conventional skull and bones in signal red colour and fixed with MS clamps bolts and nuts of approved size for LT, 20x15 cm size complete all as specified and as directed. |
| 83 | S&F sheet metal enclosures DB Double door Verticle distribution type, 04 way, TPN DB , IP43, 415V & suitable for 4 POLE MCCB as incomming including shruded neutral bar & Pan assy with earthing terminal as provided by manufacturer complete all as specified and as directed.Note : - MCCB shall be measured and paid separately |
| 84 | S&F in replacement of MCCB TPN 100 Amps 415 Volts 16 KA as per suitable sample of size complete all as specified and as directed. |
| 85 | S&F in replacement of MCCB 160 Amps 4 pole 25 KA 415 volts complete all as specified and as directed. |
| 86 | S&F in replacement of MCCB 250 Amps 4 pole 36 KA 415 volts complete all as specified and as directed. |
| 87 | Supply & fixing in replacement of MCB SP 6 t0 32 amps 230 Volt complete all as specified and as directed. |
| 88 | S&F in replacement of MCB SPN 32 Amps 230 Volts complete all as specified and as directed. |
| 89 | S&F in replacement of MCB TPN 40 amps 415 Volt complete all as specified and as directed. |
| 90 | S&F street light GI pipe bracket 50 mm dia 1.50metre length (ISI marked) light grade bend to shape with two Nos MS clamp duly painted nuts and bolts etc complete all as specified and as directed.Note :Brackets to be installed / grouted on wall or pole upto 11 mtr height. |
| 91 | S&F syntex street light box with 3 phase aluminium bus bar including 6 Amps SP MCB with mounting /fixing acessories complete all as specified and as directed. |
| 92 | M&L for scrapping of surface of steel tubular poles of any size with emery paper and painting of pole one coat of primer and two coats of silver colour paint including writing pole No on yellow colour with 30cm strip upto 1.5 Mtr height from ground level complete all as specified and as directed. |
| 93 | Supply , installation, commissioning and testing of AC, 3 phase,415 volts,50 Hz,out door type control panel factory made free standing ,dust proof, vermin and water proof tecno modular fully bolted with concealed hinges for all doors & PU foam gasket at doors, fabricated out of 3.15 mm thick CRCA sheet with front & backside door and locking arrangement, degree of protection-54. The metal will be treated in ten tank process . After thorough treatment , the panel will be epoxy powder coated, painted with standard and approved color including volt meter, amp meter, indicator lamps, selector switches Fully compartmentalized designed. Inspection at factory premises. IP-54 certificate of CPRI also required complete all as specified and as directed.INCOMER : (i) MCCB 150 Amp, 25 KA, 4 pole 415 volts.1 No (incoming), OUTGOING : (i) MCCB 63 Amp, 25 KA, 4 pole 415 volts - 01 Nos (ii) Fountain Motor Starter with complete protection - 01 Nos(iii) MCB TPN 63 Amps, TP, 10 KA, 'C' curve - 01 No.(iv) Ashtronomical time switch - 01(v) Push buttonn Green((Start) with element - 01 No.(vi) Push buttonn Red((Stop) with element - 01 No.(vii) Indicator LED ON 220V AC(viii) Control MCB 6 Amps, SP, 10 KA - 01 No.Note : MCCBs shall be adjustable thermal magnetic release setting |
| 94 | M & L for earthing with steel earth plate electrode of size 600 x 600 x 6 mm thick buried directly in ground to a depth not less than 2.25 mtr deep below normal ground level with top edge of the earth plate not less tha 1.5 mtr deep below normal grund level connected to galvanized iron strip size 32 x 6 mm as earthing lead by means of nuts, bolts and washers of steel after wlding of GIstrip to earth electrode to the full length of earht plate, 40mm dia GI tubing lightgrade protection pipe upto test point, 20mm dia GI watering pipe with funnel and wire mesh, PCC pit 1:3:6 with pit cover ofsize 30x30 cm made of RCC 1:3: with suitable handle, angle iron frame made of angle iron of size 40x40x4m, adequate qty of charcoal dust and salt layers all around the earth plate and filling of vegetables soil to the remaining 10% removal of surplus soil and retruning filling in all as required at site including test point made outof steel plate of size 75x75x6mm fixed to wall all as specified in plate No 3 of SSR Part-I and complete all as specified and as directed. |
| 95 | M&L earthing complete with galvanized steel earth plate electrode 600x600x6.3 mm thick buried directly in ground (earth pit not less than 2.25 mtr deep below normal ground level) with top edge of the plate not less than 1.5 mtr below normal ground level,the earth electrode surrounded by adequate quantity of charcoal dust and salt to a packed thickness of 15cm on all side and including connected toand including galvanized earth lead wire 4.0 mm dia upto 7.5 mtrs long by means of nuts and bolts, check nuts and washers of GI and connected to earhing test point and earth dolly all as shown in electrical plate No 3 of MES SSR part I and testing on completion including necessary excavation and earth work in any type of soil,PCC(1:3:6)type C1 chamber,pre-cast RCC slab 50mm thic in cement concrete (1:2:4),type B1,reinforced with welded steel wire fabric or XPM,(weight not less than 4 Kg per Sqm) with cast iron frame,funnel with watering pipe 20mm dia medium grade,wire mesh and lugs,GI protection pipe,15mm dia,light grade,7.5 mtr long for protection of earth lead upto test point etc complete all as specified and as directed. |
| 96 | S&F aluminium strip 25 mm x 4 mm complete with saddles and fixing screws etc for roof conductors and down conductors above ground level including removing u/s strips complete all as specified and as directed. |
| 97 | S&F single pointed air termination aluminium rod,12 mm dia, 300 mm long complete all as specified and as directed. |
| 98 | S&F porcelain strip holder on wall and roof of suitable size including removing broken u/s one complete all as specified and as directed. |
| 99 | M&L 32 mm GI pipe light grade of 1.3 mtr piece fixing in PCC cubical and complete connection of existing air termination rod complete all as specified and as directed. |
| 100 | M&L for PCC 1:3:6 type C1 (using 20 mm graded stone aggregate) as in coping and necessary form work, weathering slightly rounded or chamfered angles and throating etc complete all as specified and as directed. |
| 101 | Taking down unserviceable street light fitting upto 11 mtrs /LED Street Light fitting/Flood light Fitting of any size from the pole/bldg and kept in safe custody for refixing or for schedule of credit to contractor complete all as specified and as directed. Note : All T&P ie ladder,Tools,Safty glooves etc will be provided by the contractor without any extra cost |
| 102 | M&L for refixing and reconnecting up complete LED street light/Flood light fitting after rectification of defects in wiring of the fitting in an including replacement of holders, PVC connector, ballast, ignitor, condesor and lamp and making electric connection with PVC unsheathed wire with old or new conductor with OH line or Bus bar box complete all as specified and as directed.Note : All T&P ie ladder,Tools,Safty glooves etc will be provided by the contractor without any extra cost |
| 103 | S&F in replacement post top lantern LED 40 W or next highest wattage having IP65 protction for single phase connection 50 Hz 230 Volts complete all as specified and as directed. |
| 104 | S&F LED street light fitting 45 Watt pressure die case aluminium housing LED street light luminaires suitable for existing street light pole including all fixing accessaries complete all as specified and as directed. |
| 105 | S&F LED street light fitting 60 Watt pressure die case aluminium housing LED street light luminaires suitable for existing street light pole including all fixing accessaries complete all as specified and as directed. |
| 106 | S&F LED flood light luminarie 70 W with high pressure die cast housing acting as heat sink in order to ensure better performance having IP66 ingress protection complete all as specified and as directed.Note : All T&P ie ladder,Tools,Safty glooves etc will be provided by the contractor without any extra cost to height upto 25 mtr |
| 107 | S&F LED flood light luminarie 100 W with high pressure die cast housing acting as heat sink in order to ensure better performance having IP66 ingress protection complete all as specified and as directed.Note : All T&P ie ladder,Tools,Safty glooves etc will be provided by the contractor without any extra cost to height upto 25 mtr |
| 108 | S& fixing LED flood light luminarie 200 W with high pressure die cast housing acting as heat sink in order to ensure better performance having IP66 ingress protection complete all as specified and as directed. |
| 109 | S&F single phase driver for LED street light / flood light of 45 to 200 watt capacity and compatible with existing street light/ flood light any type / any rating complete all as specified and as directed. |
| 110 | S&F automatic street light prewired switch using nature switch for automatic switching of street light based on lux level of nature light.THE SENSOR (NATURE SWITCH) alongwith power contactor for 25 KW 3 phase,MCB pole/wall mountable enclosure made of rust proof electric shock proof terminal proof and FR grade special moulding compound junction box confirming to IP54 with all other accessoried ie lugs cable connedtion etc complete all as specified and as directed. |
| 111 | S&F in replacement non-metallic junction box/street light box with three phase aluminium bus bar of suilable for 415 Volt , 50 Hz electric supply conforming to IP65 wall / pedestral mounted and including MCB SPN 06 Amps complete all as specified and as directed. |
| 112 | S&F steel pole tubular swaged 9 metres long complete with cast iron base plate , finialtaper plug , bolts , nuts and screws as specified type 410 SP-22 complete all as specified and as directed. |
| 113 | S&F in replacement LED bollard fitting 9 Watt with luminaire with MS Pipe housing with glare free PMMA diffuser , IP65 of height 1200 mm suitable for single phase connection 50 Hz 230 Volts complete all as specified and as directed. |
| 114 | Supply and errection in true vertical position 6 mtr long MS pole on pcc foundation suitable for 47 m/s wind speed with 4-8, 590mm PCD of foundation bolts complete with MS base plate of 300mmx300mmx6mm at bottom and swages from base to top in such manner that 114.3mm x 3.65mm upto 3 metres, 88.9mm x 3.25mm upto 1.5 metres , 76.1mm x 3.25mm upto 1.5 metres, above base plate with arm to fix solar street light at top and final tape plug, bolts, nuts, washers and screws incl painting with black bituminous paint two coat over one coat or red oxide primer after errection complete and marking pole number on pole complete all as specified and as directed.Note : (i) Earth work and PCC foundation work shall be measured and paid separately.(ii) Description as per direction of Engineer-in-Charge will be printed on each pole without any extra cost. |
| 115 | M & L cement concrete in foundation filling and mass concrete type B2 1:3:6 (40mm graded stone aggregate) complete all as specified and as directed. |
| 116 | M & L cement concrete in foundation filling and mass concrete type B2 1:4:8 (40mm graded stone aggregate) complete all as specified and as directed. |
| 117 | Supply and laying or fixing or passing through pipe, 1100 volts grade heavy duty cable with PVC insulated aluminium conductor served with an inner sheathing of PVC tape with galvanised steel wire or tape and overall PVC sheathed 4 core 10 sq. mm nominal cross section in service connections including takind down old u/s complete all as specified and as directed. |
| 118 | Supply and laying or fixing or passing through pipe, 1100 volts grade heavy duty cable with PVC insulated aluminium conductor served with an inner sheathing of PVC tape with galvanised steel wire or tape and overall PVC sheathed 2 core 6 sq. mm nominal cross section in service connections complete all as specified and as directed. |
| 119 | M&l in replacement tubing light grade galvanized iron to be embeded in PCC block fitting complete with 40 mm bore complete all as specified and as directed. |
| 120 | S&F in repair/replacement of solar street light fittings with integrated 12 Watt LED street light system with solar PV Panel 100 WP, integrated LED fitting with Li-Ion Battery 11.1 V 17 Ah , MPPT based solar charge controller,Motion Sensor and tubular pole of height 5 Mtrs complete all as specified and as directed. |
| 121 | Supply and connecting single core FR, PVC insulated stranded copper conductor cable of size 1.5 sqmm for street light passing through pole hole/GI pipe/PVC conduit to junction box and connected electrically including taking down old unsv wire any type any make complete all as specified and as directed.NOTE - Three runs of wire is measured as one RM. |
| 122 | M&L for servicing of split type AC's of capacity 1.5/2 TR comprising of the following tasks installed at different locations including testing complete all as specified and as directed.(a) Inspecting and checking the Indoor/outdoor units for noise free operation.(b) Checking the electrical connection for tightness(c) Cleaning the condenser with cleaning agent followed with pressurized water and cleaning the cooling coil with air blower with water pressure gun.(d) Greasing/Oiling of condenser fan motor and blower motor.(e) Checking for any refrigerant leakage by pressure testing and repair it.(f) Checking for serviceability of remote control unit and replace with new battery. |
| 123 | M&L for servicing of window type AC's of capacity 1.5 TR comprising of the following tasks at different locations including Refixing, commissioning and testing complete all as specified and as directed.(a) Inspecting, taking down, brushing cleaning with water pressure gun including acid/detergent wash of condenser and cooling coil.(b) Carry out operation of blower and compressor and ensure that satisfactory functioning of all parts.(c) Inspecting the leakage in the system by pressure test and repair it.(d) Checking of the earth continuity of electrical parts.(e) Checking the functioning of thermostat.(f) Inspection of all electrical parts.(g) Testing the machine for satisfactory operation. |
| 124 | M&L for repair to leaking area of split type AC unit of capacity 1.5/2 TR capacity including nitrozen pressure testing, dehydration and any type of gas charging complete all as specified and directed by engineer-in-charge. |
| 125 | M&L for repair to leaking area of window type AC unit of capacity 1.5 capacity including pressure testing, dehydration and any type of gas charging complete all as specified and as directed. |
| 126 | Supply and charging Refrigerant(R410,R32,R134 and existing refrigerent) to any type of AC unit including CFC free and non CFC Free AC complete all as specified and as directed. |
| 127 | S&F in replacement of starting relay 25 Amps for split type AC units of capacity 2 /1.5TR as required at site complete all as specified and as directed. |
| 128 | S&F in replacement of start run capacitor 45/60 MFD for split type A/C's of capacity 1.5/2 TR complete all as specified and as directed. |
| 129 | S&F in replacement of running capacitor for 36/60 mfd for AC window type 1.5 TR as required at site complete all as specified and directed. |
| 130 | S&F in replacement of running capacitor 6 mfd for blower motor as required at site complete all as specified and as directed. |
| 131 | Taking out and replacement of condenser fan motor DC of split type AC 1.5/2 ton units of capacity 1.5/ 2 TR complete all as specified and as directed. |
| 132 | Taking out and replacement of condenser fan motor AC of split type AC units of capacity 1.5/ 2 TR complete all as specified and as directed. |
| 133 | M&L for Fixing the new blower motor DC in replacement of for split type A/C unit as per existing model complete all as specified and as directed. |
| 134 | S&F the new blower motor AC for split type A/C unit as per existing model complete all as specified and as directed. |
| 135 | S&F in replacement of new blower motor for window ac as required at site single phase 230 volts double shaft with clamp bolts, nuts and rubber bushes including testing & commissioning complete all as specified and as directed. |
| 136 | S&F in replacement the new swing motor as per existing model/make for split type AC 1.5/2TR unit complete all as specified and as directed. |
| 137 | S&F out door fan blade in existing model complete all as specified and as directed. |
| 138 | M&L for replacement of defective electronic components / IC Circuits of PCB card with display unit suitable of 1.5/2 ton split AC indoor unit as required on site including replacement of defective electronic components / IC Circuits complete all as specified and as directed. |
| 139 | M&L for replacement PCB card suitable of 1.5/2 ton inverter split AC as required on site complete all as specified and directed by Engr-in-Charge including sensor complete all as specified and as directed. |
| 140 | M&L for replacement PCB card suitable of 1.5/2 ton window as required on site complete all as specified and directed by Engr-in-Charge including sensor complete all as specified and as directed. |
| 141 | Disconnecting and taking down burnt condenser coil of capacity 1.5TR from split type AC unit and S&F new copper condesor coil as per existing model complete including testing complete all as specified and as directed. |
| 142 | M&L for replacement of cooling coil assembly complete suitable for 1.5 / 2 ton indoor unit Split type AC incl testing for satisfactory working condition complete all as specified and as directed. |
| 143 | Materal and Labour for replacement cooling coil of window type AC 1.5 TR including after taking out old unserviceable one,soldering/welding dehydration complete all as specified and as directed. |
| 144 | Disconnecting & taking down of window type AC of any make for replacement of condenser coil of existing size including soldering/welding and resting commissioning complete all as specified and as directed. |
| 145 | Disconnecting and taking down burnt compressor of capacity 1.5TR from split type AC unit and S&F new one as per existing model complete including testing complete all as specified and as directed. |
| 146 | S&F in replacement of indoor unit for split type AC complete with motor, blower, remote control, filters having cooling capacity 6000 K.Cal/Hr hi wall split units indoor copper tube unit capcity of 2 Ton complete with cordless remote control unit and with in built air ioniser and plasma filter for better indoor quality with minimum 5 star rating and EER 3.2 of capcity 2 ton fitted on wall or requirement place including all neccessary electrical connections, bolting, nuts, clamping of 3 core copper cable, cooling tube, drain water pipe etc complete all as specified and as directed.Note:- Contractor shall be submitted minimum 3 years warranty along with bill |
| 147 | Disconnecting and taking down burnt compressor of capacity 2TR from split type AC unit and S&F new one as per existing model complete including testing complete all as specified and as directed. |
| 148 | M&L for replacement of 'R' type compressor for Window type AC,1.5 TR as per existing make including taking out old unserviceable one,flushing, dehydration and gas changing complete all as specified and as directed. |
| 149 | Labour for dismantling of Split AC 1.5/2 ton complete unit from the existing place complete all as specified and as directed. |
| 150 | Labour for fixing of Split AC 1.5/2 ton including masonary work complete unit complete all as specified and as directed. |
| 151 | Labour for dismantling of window AC 1.5 ton from the existing place complete all as specified and as directed. |
| 152 | Labour for fixing of window AC 1.5 ton complete all as directed. |
| 153 | M&L install wall mounted stand for mounting indoor unit of split AC complete with all fixing arrangement complete all as specified and as directed. |
| 154 | M&L wall mounted stand for mounting outdoor unit of split AC complete with all fixing arrangement complete all as specified and as directed. |
| 155 | M&L in repairs copper tubing 3/8” outer dia suitable for AC 2TR capacity complete all as specified and as directed. |
| 156 | All as per item No 155 above but here in before but 5/8” outer dia. |
| 157 | M&L for providing insulation 9mm thick for dia 1/4\\",3/8\\",1/2\\",5/8\\",6/8\\" copper tubing’s from Indoor to outdoor units with foam insulation followed with clamps complete all as specified and as directed. |
| 158 | M&L for the new remote with battery as per existing model for 1.5/2 TR split type A/C unit complete all as specified and as directed. |
| 159 | M&L in replacement of wall mounted Voltage stabilizers 4/5 KVA single phase,230 Volts AC,voltage variation between 140- 300,intelligent time delay system,digital display,low and high voltage cut-off system, complete all as specified and as directed. |
| 160 | M&L in replacement 3 core copper PVC insulated of size 4 Sqmm complete all as specified and as directed. |
| 161 | S&F in replacement of outdoor unit for split type AC complete of capacity 6000 K.Cal/Hr with charging valves and gas filter with compressor complete suplly and install hi wall split units outdoor copper tube evaporator and condencing unit capacity of 2 Ton complete with minimum 5 star rating and BEER 3.2 of capacity 2 Ton fitted on wall and out door to be fixing on wall/roof at requirement place including all neceesary electrical connections , bolting , nuts clamping, frame . stand and 3 core copper cooling tube , drain water pipe etc complete all as specified and as directed.Note:- Contractor shall be submitted minimum 3 years warranty along with bill |
| 162 | M&L for repair & maintenance of Refrigerator / Water Cooler any capacity comprising of the following tasks at different location complete all as specified and directed by Engineer-in-Charge.(a) Inspecting, taking down, brushing cleaning with blower including acid/detergent wash of condenser and cooling coil.(b) Carry out operation of blower and compressor and ensure that satisfactory functioning of all parts.(c) Inspecting the leakage in the system.(d) Checking of the earth continuity of electrical parts.(e) Checking the functioning of thermostat.(f) Inspection of all electrical parts.(g) Testing the machine for satisfactory operation.(h) Check and correct all electrical wiring & test its functioning(j) Testing of Refrigerator after repair. |
| 163 | M & L for replacement of unserviceable sealed compressor with new hermetic sealed compressor of existing make including charging of refrigerant gas and testing on full load complete all as specified and as directed. |
| 164 | M & L for replacement of unserviceable compressor with new compressor of existing make including charging of refrigerant gas and testing on full load complete all as specified and as directed. |
| 165 | Taking down desert cooler of any size by disconnecting electrical supply, cleaning, oiling of all moving part of pump & exhaust fan/kit, Replacing PVC pipes, nozzles, distributors, pads, checking electrical connections complete all as specified and as directed. |
| 166 | M&L in replacement of wood pads(set of three)as per sample complete all as specified and as directed. |
| 167 | M&L in replacement the new desert cooler pump.including testing for proper functioning complete all as specified and as directed. |
| 168 | M&L in replacement the new exhaust fan kit with leg assembly 450mm sweep complete all as specified and as directed. |
| 169 | M&L in replacement the new exhaust fan motor with leg assembly 450mm sweep complete all as specified and as directed. |
| 170 | M&L in replacement the new exhaust fan blade 450mm sweep, complete all as specified and as directed. |
| 171 | M&L in replacement new body of desert cooler of 600 x 600 x 900 mm size or in next higher size in volume duly painted of 20 SWG sheet with 22 SWG flops, front grill, PVC pipe, nozzle,selector switches,swinging motor,distributor and nut bolts washers for fixing fan clamps, complete all as specified and as directed. |
| 172 | M&L front grill of desert cooler as per sample complete all as specified and as directed. |
| 173 | M&L for PVC flexible distributor heavy duty with nozzle as per sample complete all as specified and as directed. |
| 174 | M&L in repairs,Single pole and neutral enclosure with a two pin and earth plug and socket complete with one single pole MCB 32 Amp, complete all as specified and as directed. |
| 175 | M&L in replacement of 3 pin socket metalic plug top industrial type complete all as specified and as directed. |
| 176 | Taking down storage water heater 25 ltrs capacity from wall for repair/replacement of unserviceable parts and refixing with fasterners Nuts and washers the same after repair work complete all as specified and as directed. |
| 177 | M&L for replacement of thermostate 0-60 degree as per sample in water geyser 25/50 litre capacity ISI Make as per sample complete all as specified and as directed. |
| 178 | M&L for replacement of heating element 1.5KW,Triangular/round type as per sample complete all as specified and as directed. |
| 179 | M&L for replacement of heating element 2 KW with complete assembly of any model and type as per site requirement /sample complete all as specified and as directed. |
| 180 | M&L for disconnecting from electric and water mains and dismantling the unserviceable gyeser base assembly and replacing the new base assembly 6/9 holes with rubber gasket for 25 Ltrs capacity of any make and refixing in original place including recoonecting of electric and water supply mains including testing complete all as specified and as directed. |
| 181 | M&L for replacement of geyser outer body cover of 25 Ltr capacity made out of 16 SWG powder coated complete with all connected accessories suitably fitted with existing wall complete all as specified and as directed. |
| 182 | M&L for replacement of geyser tank stainless steel suitable for 25 Ltr capacity geyser complete all as specified and as directed. |
| 183 | M&L for replacement of PVC connection with brass inserts suitable for hot/cold water, 60 cm long (for hot and cold water inlet and outlet) having PTMT nuts with washer complete all as specified and as directed. |
| 184 | S & F in Replacement of bottom cover suitable cylindrical type geyser as per existing required as per site for 25 Ltrs capacity complete all as specified and as directed. |
| 185 | Dismantling and opening storage tank of geyser 25 litre capacity to identify the leakage ,repair the spot by suitable welding carefully including making good insulating material, assembling and testing complete all as specified and as directed. |
| 186 | S & F in replacement of indication lamp red and green (pilit type ISI marked) for 25 Ltrs water heater complete all as specified and as directed. |
| 187 | S&F in replacement of PVC insulated flexible copper conductor cable 40/0.0076 size 3 core suitable for 650 volts grade complete all as specified and as directed. |
| 188 | S & F in replacement of glass wool in any capacity of geyser complete all as specified and directed by Engr - in- charge. |
| 189 | Taking down ceiling fan complete any type size from existing location and cleaning body blades etc including servicing, greasing,oiling,replacing wornout bearing ,bush and refixing the same at site complete all as specified and as directed. |
| 190 | All as per item No 189 above but for Exhaust fan complete. |
| 191 | All as per item No 189 above but for wall/floor mounted fan . |
| 192 | M&L for rewinding unserviceable ceiling fan 1200/1400 mm Sweep from site by strip opening,cutting removing the burnt winding from starter cleaning the slots and rewind the same with original guage of super enameled copper winding wire, insulation materials and all accessories & varnishing etc replacement of service wire copper twisted size 23/0.0076 including reassembling the fan complete all as specified and as directed. |
| 193 | All as per item No 192 above but for Exhaust fan 300 mm sweep complete |
| 194 | All as per item No 192 above but for wall/floor mounted fan 450 mm sweep. |
| 195 | M&L for painting of ceiling fans complete, in situ with synthetic enamel paint by spraying including filling cavities with filler, one coat after cleaning all dust etc complete all as specified and as directed. |
| 196 | M&L for Replacement of old unserviceable fan blades, (ISI Marked), suitable for 1200mm sweep ceiling fan duly painted in white/brown by using spray gun method(fully furnished) complete all as specified and as directed. |
| 197 | M&L for Repalcement of old unserviceable down rod of ceiling fan of dia 20mm bore \\"medium grade\\" complete with split pin, hanging clamp and rubber real (length of rod not less than 45cm and not more than 60cm) dully painted in white/brown by using spray gun method (fully furnished) complete all as specified and as directed. |
| 198 | S&F cable PVC insulated and overall sheathed with flexible copper conductor cable of size 0.5 sqmm,3 core cut to size of approx 0.30 metre from block of fan to ceiling rose complete all as specified and as directed. |
| 199 | M&L for replacement of old unserviceable gun metal bush of ceiling fan including neceassry laith, Grinding and welding work complete all as specified and directed. |
| 200 | M&L for replacement of old unserviceable shackle assembly kit (Rubber real -01, MS split clamp two Nos, nuts and bolts washers- 2 Nos & split pin -02 Nos) suitable for ceiling fan of 1200/1400mm sweep complete all as specified and directed. |
| 201 | M&L for replacement of old unserviceable steel screw of size 5mm to 8mm (to be used for fixing of fan blade) complete all as specified and directed. |
| 202 | S&F ceiling fans complete with blades, down rods and accessories, 230 V, 1200 mm sweep. Min air delivery 210 CFM with service value 6.00 BEE. Five star rated with brushless direct current motor (BLDC) with remote control complete all as specified and as directed. |
| 203 | S&F in replacement of exhaust fan heady duty metal body 300 mm sweep including necessary fixing arrangement for proper fixing in wall and making hole as per site requirement complete all as specified and as directed. |
| 204 | S&F in replacement of exhaust fan heady duty metal body type 250 mm sweep including necessary fixing arrangement for proper fixing in wall and making hole as per site requirement complete all as specified and as directed. |
| 205 | S&F in replacement of exhaust fan heavy duty plastic body 250 mm sweep including necessary fixing arrangement for proper fixing in wall and making hole as per site requirement complete all as specified and as directed. |
| 206 | S&F in replacement of wall mounting fan heady duty 400 mm sweep including necessary fixing arrangement for proper fixing on wall as per site requirement complete all as specified and as directed. |
| 207 | M&L for replacement of old unserviceable capacitor AC 400/415 volts 2.5 mfd (ISI marked) complete all as specified and as directed. |
| 208 | M&L for replacement of old unserviceable capacitor AC 400/415 volts 3.15 mfd (ISI marked) complete all as specified and as directed. Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Tender Published
Tender notice published.
CompletedBid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 13 daysBid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 15 daysTender Documents
Download All (ZIP) ↓We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender