Tender For General-Modernisation Of Existing Fishing Harbour At Koyilandi In Kozhikode District Of Kerala Under The Pmmsy-Providing Additional Light Masts At Berthing Jetty And Main Road , Power Connection To Cold Storage, Electrification For Etp And
Tender Overview
Project Description
Tender for General-Modernisation Of Existing Fishing Harbour At Koyilandi In Kozhikode District Of Kerala Under The Pmmsy-Providing Additional Light Masts At Berthing Jetty And Main Road , Power Connection To Cold Storage, Electrification For Etp And General Electrification-General Electrical Work
BOQ
| Sl. No. | Item Description |
| 1 | Electrical Work |
| 2 | 1.10.1:Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVCinsulated copper conductor single core cable in surface / recessed medium class PVC conduit,with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLSPVC insulated copper conductor single core cable etc as required.Group A |
| 3 | 1.10.2:Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVCinsulated copper conductor single core cable in surface / recessed medium class PVC conduit,with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLSPVC insulated copper conductor single core cable etc as required.Group B |
| 4 | 1.10.3:Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVCinsulated copper conductor single core cable in surface / recessed medium class PVC conduit,with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLSPVC insulated copper conductor single core cable etc as required.Group C |
| 5 | 1.21.1:Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required.20 mm |
| 6 | 1.17.3:Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.3 X 1.5 sq.mm |
| 7 | 9.1.32:Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.4 X 10 sq. mm (25mm) |
| 8 | 5.3:Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. (but without charcoal/ coke and salt ) as required. |
| 9 | 14.12:Providing 15mm thick cement plaster of mix 1:4(1 cement: 4 fine sand) at all levels |
| 10 | 14.10:Providing and laying in position reinforced cement concrete 1 :2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) in foundation of pump, DG set etc. including form work etc. as required (excluding reinforcement). |
| 11 | 7.10:Supplying and fixing cable route marker with 10 cm X 10 cm X 5 mm thick G.I. plate with inscription there on, bolted /welded to 35 mm X 35 mm X 6 mm angle iron, 60 cm long and fixing the same in ground as required. |
| 12 | 2.10.4:Supplying and fixing 5A to 32 A rating, 240/415 volts, 10 kA, \\"\\"C\\"\\" curve, miniaturecircuit breaker suitable for inductive load of following poles in the existing MCBDB complete with connections, testing and commissioning etc. as required.Triple pole |
| 13 | 2.3.3:Supplying and fixing following way, single pole and neutral, sheet steel, MCBdistribution board, 240 volts, on surface/ recess, complete with tinned copperbus bar, neutral bus bar, earth bar, din bar, interconnections, powder paintedincluding earthing etc. as required. (But without MCB/RCCB/Isolator)12 way, Double door |
| 14 | 2.14.2:Supplying and fixing following rating, double pole, (single phase and neutral),240 volts, residual current circuit breaker (RCCB), having a sensitivity current 30 milli amperes in the existing MCB DB complete with connections, testing and commissioning etc. as required.40 amps |
| 15 | 2.12.1:Supplying and fixing following rating, double pole, 240 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.40 amps |
| 16 | 2.10.1:Supplying and fixing 5A to 32 A rating, 240/415 volts, 10 kA, \\"\\"C\\"\\" curve, miniaturecircuit breaker suitable for inductive load of following poles in the existing MCBDB complete with connections, testing and commissioning etc. as required.Single pole |
| 17 | 2.10.3:Supplying and fixing 5A to 32 A rating, 240/415 volts, 10 kA, \\"\\"C\\"\\" curve, miniaturecircuit breaker suitable for inductive load of following poles in the existing MCBDB complete with connections, testing and commissioning etc. as required.Double pole |
| 18 | 14.1:Excavation for foundation in soft soil including dressing of sides and ramming of bottoms, lift upto 1.5 m including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 metres. |
| 19 | 5.14:Providing and fixing 25 mm X 5 mm copper strip on surface or in recess for connections etc. as required. |
| 20 | 5.13:Providing and laying earth connection from earth electrode with 4.00 mm dia copper wire in 15mm dia G.I. pipe from earth electrode including connection with copper thimble excavation and re-filling as required. |
| 21 | 5.17:Providing and fixing 4.00 mm dia copper wire on surface or in recess for loop earthing as required. |
| 22 | 9.1.35:Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.4 X 35 sq. mm (32mm) |
| 23 | 7.7.1:Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KVgrade of following size on wall surface as required.Upto 35 sq. mm (clamped with 1mm thick saddle) |
| 24 | 9.1.34:Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.4 X 25 sq. mm (28mm) |
| 25 | 14.2:Excavation for cable trenches of depth upto 1.2 m in soft soil including getting out the excavated soil and disposal of surplus excavated soil as directed within a lead of 50 metres. |
| 26 | 9.1.33:Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.4 X 16 sq. mm (28mm) |
| 27 | 90.12.7.40:Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.4 core 10 sq mm with factory made clamp |
| 28 | 90.12.5.40:Supply & laying of one number PVC insulated and PVC sheathed armoured aluminium power cable of 1.1KV grade of the following sizes in the existing RCC/ HUME / STONE WARE/ GI/ DWC pipe as required.4 core 10 sq mm |
| 29 | 90.12.7.41:Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.4 core 16 sq mm with factory made clamp |
| 30 | 90.12.5.41:Supply & laying of one number PVC insulated and PVC sheathed armoured aluminium power cable of 1.1KV grade of the following sizes in the existing RCC/ HUME / STONE WARE/ GI/ DWC pipe as required.4 core 16 sq mm |
| 31 | 90.12.5.42:Supply & laying of one number PVC insulated and PVC sheathed armoured aluminium power cable of 1.1KV grade of the following sizes in the existing RCC/ HUME / STONE WARE/ GI/ DWC pipe as required.4 core 25 sq mm |
| 32 | 90.12.7.42:Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.4 core 25 sq mm with factory made clamp |
| 33 | 90.12.7.43:Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.4 core 35 sq mm with factory made clamp |
| 34 | 90.12.5.43:Supply & laying of one number PVC insulated and PVC sheathed armoured aluminium power cable of 1.1KV grade of the following sizes in the existing RCC/ HUME / STONE WARE/ GI/ DWC pipe as required.4 core 35 sq mm |
| 35 | 90.12.5.45:Supply & laying of one number PVC insulated and PVC sheathed armoured aluminium power cable of 1.1KV grade of the following sizes in the existing RCC/ HUME / STONE WARE/ GI/ DWC pipe as required.4 core 70 sq mm |
| 36 | 90.12.7.45:Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.4 core 70 sq mm |
| 37 | 90.12.9.3:Supplying, laying and jointing of the following sizes of double wall corrugated (DWC) pipes made out of HDPE conforming to IS 14930 Part II for mechanical protection to underground power cables with all required accessories in ground in the existing trench63/50 mm or nearest size |
| 38 | 90.12.9.2:Supplying, laying and jointing of the following sizes of double wall corrugated (DWC) pipes made out of HDPE conforming to IS 14930 Part II for mechanical protection to underground power cables with all required accessories in ground in the existing trench50/38 mm or nearest size |
| 39 | 90.16.1.3:Supply and drawing bare earthing conductors of the following sizes along with wiring/ cables and giving connection as required3.15 mm copper conductor ( 10 SWG) |
| 40 | 90.16.5.3:Supply of superior quality copper earth socket for the following size of earth conductor including crimping etc. as required.3.15 mm (10 SWG) |
| 41 | 90.15.4.3:Supply Conveyance, installation, testing and commissioning of 70W LED street light output greater than 105lumen/W 4000-6000 K with IP 66 protection LED Chip make Cree/Lumilled/Nichea with power factor greater than 0.95 at full load, internal surge protection up to 8 KV,and Aluminium pressure die-cast Powder coated housing,acrylic cover complete with THD Less than 10%, power factor greater than 0.98, RoHS compliant, duly wired up for use on 230 V AC supply. Driver compartment should be seperatly accessible for maintenance (LM 79&80 certificates from NABL accredited Third party lab to be produced mentioning chip manufacturer) |
| 42 | 90.12.39.37:Supply & laying of one number PVC insulated and PVC sheathed armoured copper power cable of 1.1KV grade of the following sizes in the existing RCC/ HUME / STONE WARE/ GI/ DWC pipe as required.4 core 50 sq mm |
| 43 | 90.14.10.3:Supply, conveyance and fixing the following types & current rated control gears & switchgears conforming to IS 13947 suitable for 440 V, 50 Hz, AC supply in the existing panel assembly as required.16 A-100A, 16 kA (Ics=100%Icu), 4 pole, current limiting type MCCB having thermal setting range of 80 - 100% with thermal magnetic release having adjustable OL |
| 44 | 90.15.4.2:Supply Conveyance, installation, testing and commissioning of 36/40W LED street light output greater than 105lumen/W 4000-6000 K with IP 66 protection LED Chip make Cree/Lumilled/Nichea with power factor greater than 0.95 at full load, internal surge protection up to 8 KV,and Aluminium pressure die-cast Powder coated housing,acrylic cover complete with THD less than 10%, power factor greater than 0.98, RoHS compliant, duly wired up for use on 230 V AC supply. Driver compartment should be seperatly accessible for maintenance (LM 79&80 certificates from NABL accredited Third party lab to be produced mentioning chip manufacturer) |
| 45 | 90.16.5.4:Supply of superior quality copper earth socket for the following size of earth conductor including crimping etc. as required.4.00 mm (8 SWG) |
| 46 | 90.12.7.44:Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.4 core 50 sq mm |
| 47 | 90.15.3.5:Supply installation testing and commissioning of Octogaonal Pole made of hot dip galvanised GI sheet 70 mm top diameter, 130 mm bottom diameter thickness 3mm base plate dimensions of 200x200x12 mm suitable for wind speed as per IS 875 Part III single arm bracket 0.5mt including connector foundation bolt 4 nos fixed in existing RCC foundation and junction box etc. complete 7 Meters |
| 48 | 90.15.3.6:Supply installation testing and commissioning of Octogaonal Pole made of hot dip galvanised GI sheet 70 mm top diameter, 130 mm bottom diameter thickness 3mm base plate dimensions of 200x200x12 mm suitable for wind speed as per IS 875 Part III double arm bracket 0.5mt including connector foundation bolt 4 nos fixed in existing RCC foundation and junction box etc. complete 7 Meters |
| 49 | 90.15.4.11:Supply Conveyance, installation, testing and commissioning of 200W LED Flood light output greater than 105lumen/W 4000-6000 K with IP 66 protection LED Chip make Cree/Lumilled/Nichea with power factor greater than 0.95 at full load, internal surge protection up to 8 KV,and Aluminium pressure die-cast Powder coated housing, acrylic cover complete with THD less than 10%, power factor greater than 0.98, RoHS compliant, duly wired up for use on 230 V AC supply. Driver compartment should be seperatly accessible for maintenance (LM 79&80 certificates from NABL accredited Third party lab to be produced mentioning chip manufacturer) |
| 50 | OD3161/2026-2027:Supply Conveyance, installation, testing and commissioning of 300W LED Flood light output greater than 105lumen/W with 60 degree beam angle, 4000-6000 K with IP 66 protection LED Chip make Cree/Lumilled/Nichea /Havells/Wipro with power factor greater than 0.95 at full load, internal surge protection up to 8 KV,and Aluminium pressure die-cast Powder coated housing, acrylic cover complete with THD less than 10%, power factor greater than 0.98, RoHS compliant, duly wired up for use on 230 V AC supply. Driver compartment should be seperatly accessible for maintenance (LM 79&80 certificates from NABL accredited Third party lab to be produced mentioning chip manufacturer) |
| 51 | 90.6.5.12:Supply and drawing the following sizes of multi-core PVC insulated & FRLS PVC sheathed 650/1100 V grade copper conductor round flexible cables conforming to IS 694 part I 1960 in the existing surface / recess conduit as required including giving necessary connections of the following sizes.3 core 2.50 sq mm |
| 52 | 90.6.6.1:Supply and drawing FRLS PVC insulated & sheathed 650/1100 V grade 3 core copper conductor flat cable for submersible pump motor conforming to IS 694 part I 1990 as required including giving necessary connections of the following sizes.1.50 sq mm |
| 53 | OD3149/2026-2027:Engaged Labour for maintenance work for dismounting/fixing the existing light fittings, cables and other electrical accessories from the existing structure including rectifying minor defects, tightening nut and bolts ,overall check-up, change the cable and welding and fabrication work for minor defects including materials complete as directed by engineer in charge at site including all maintenance work complete as required. |
| 54 | OD3150/2026-2027:Supply and installation of extra length of foundation bolt of size 16mm diameter 200mm pitch circle diameter manufactured from special steel ( suitable for 10 M octogonal pole) in existing cement concrete complete as required. |
| 55 | OD3432/2025-2026:Supply and installing RCC precast well steining of size 750mm dia and 300m height complete with all expense at site. |
| 56 | OD3444/2025-2026:Supply and providing First Aid Chart duly framed and placed in a conspicuous location for clear vision |
| 57 | OD3151/2026-2027:Supply and providing 2.5 mm thick,1m x 2m Synthetic polymer/PVC blend electrical grade Checkered type rubber mat suitable for Medium Voltage installations have IS 15652:2006 Standard ,Class B,Dielectric Strength of 45 kV AC for 1 minute,Self-extinguishing,Anti-skid checkered or dotted top surface and plain at bottom at site complete as required. |
| 58 | OD3438/2025-2026:Supply and providing laminated drawings of electrical layout,schematic drawingetc on good frame work and placed in a conspicuous location for clear vision |
| 59 | OD3408/2025-2026:Supply, installation, testing and commissioning (SITC) of outdoor type, weatherproof, dust and jet-water proof Polycarbonate Cable Junction Box of overall outer dimensions 300 x 150 x 170 mm in Black color (UV-resistant for harsh outdoor exposure), equipped with metric knockouts on all sides for cable gland entries, complete with hand-operated quick-release retention screws and continuous high-grade sealing gasket. The enclosure shall have an ingress protection rating of IP66 / IP67, mechanical impact resistance rating of IK08 / IK09, and weather resistance suitable for outdoor installation. |
| 60 | OD3451/2025-2026:Fabricating, supplying, erecting and commissioning of fully compartmentalized, dust and vermin proof cubicle Main panel board of size 1250x1250x250mm or nearest suitable size using 14 G CRCA MS sheet, painting two coats of best quality epoxy paint over two coats of epoxy primer of approved quality, having , front openable bolted type vertical bus bar chamber & cable alleycovers with cable entry provisions and bolted type cable glanding plate using 14 SWG CRCA MS sheet at the top and bottom. The panel should have 75x40x4.4mm MS channel provided at the bottom as support and comprising the following(Panel drawing attached with the schedule) Incomer: 250A, 4pole, AC 23A ON LOAD change over switch - 1 NoIncoming:- 250A, 35kA FP MCCB setted to 50A and rotory drive kit including BUC handle and shunt release withauxiliary contact- 1NoOutgoing:-100A 30kA, 4pole MCCB - 1No with rotary drive kitOutgoing:-100A 16kA, 3pole MCCB - 4No with rotary drive kit and 100A porcealin 2 way neutral link.All switches and MCCB should be of panel mounting and conforming to IS:13947partIII (L&T/ SIEMENS/ Legrand/HPL/Socomec )Busbar Chamber: Busbar chamber with 25X3mm Copper strips 4 Nos or equivalent size one each for phases and neutral fitted on epoxy insulator. Switch interconnections to be done with suitably rated Copper conductors insulated with PVC heat shrinkable sleeves. Interconnections with the incoming and busbar is also to be carried out using 25x3mm PVC insulated Copper strips supported using epoxy insulators and outgoing with suitable rated copper conductor as required. Panel internal earthing should be provided using 25x3mm copper strip with two earthing points brought out at bottom side. Protection :- Under & Overvoltage relay (Auto/ manual reset ,Trip time and Power on delay 1 - 10 sec) OV / UV - adjustable ELR with CBCT current setting 0.03 A to 1A with time setting - 1 NoSupply and fixing DIN Rail Surge Protection Device Class B & Class C/ Type 1 & Class 2 Tested as per IEC 61643 Part 11:2011 . Nominal voltage -230V 50/60Hz, MCOVof 275 V , Total Impulse current-50 KA (10/350µ sec) & Total Max Discharge current 200KA (8/20µ sec), Voltage protection level <1.5 kV & Residual Voltage @ 5 kA(8/20) <0.8 kV . The Surge Protection Devices should have TOV withstand for 120 Min : 438 V and with out Follow Current & Leakage Current. Protective Elements are High Energy MOV & GDT & the Protection Modes for : L & N to PE . Short- Circuit Current rating (Isccr) ? 25 kA/50 Hz . Back up fuse required morethan 160AgG/gL. Health Status Indication required in all cartridge. Total Response time Metering and Indication : Panel surface mounting 96 Sq.mm,LED Multi-function meter with three line display to read V,A,,kVA,kVAr,PF,& F with RS 485 communication port of make SCHNEIDER or equivalent suitable for 415V,50Hz- 2No, and 3 Nos 250/5 A class 1 Tape wound CTs, 22.5mm dia LED type indication lamps for three phases(R,Y &B) - 2 set on hinged shutters with quarter turn key locks for each cubicle and control Group B 2A SP MCB (C Curve)-6 numbers inside the cubicle. The panel board should have hinged shutters for MCCB cubicles with quarter turn lock and key for each cubicle and front openable bolted type busbar covers and it should be fabricated as per Kerala State Electrical Inspectorate's norms and only after obtaining approval from the departmental officers at site for the design. Sub metering : Outgoing feeder wise metering employing panel door mounting backlit LED 96x96 mm, 3phase 4 wire class 1 , -/5 A electronic energy meters with 100/5 CTs-3 set ofapproved quality and having ISI mark is to be installed in the separate metering cubicle provided in the main panel . Kerala Electrical Inspectorate/KSEB approved test certificate is to be produced for the energy meters at the time of supply of the panel. All power /control wiring shall be done using adequate size coppercable with copper socket |
| 61 | OD3453/2025-2026:Dismantling existing tubular post of height 12m from foundation ,conveying, lifting, and erecting tubular post on a RCC footing, using 1:2:4 CC with nominal reinforcement and 6 Nos. of PCC well steining having 0.9m dia and 0.30m height with a muffing of 0.6mx0.6mx1m and 8 numbers of 20mm dia 2.50m long MS foundation bolts having 150mm long standard thread on both ends and 3Nos 20mm and 2Nos 20mm nuts at the top and bottom for each bolt. The post is to be provided with a 20mm thick MS flange of OD 300mm with 8 nos of 20mm bolt holes and a base plate of 600mm square 10mm thick with 8 Nos 20mm dia bolt holes embedded in the concrete 1.8m below ground level. . The top of the pipe should be sealed with 125mm table F Dummy flange. 12mm dia wire rope is to be provided for the entire length of the post as a mechanical support for the cables to the luminaries. Inverted Y arrangement using 50mm heavy GI pipe, flange, and dummy flange cover, and 75mm 4kgf/cm2 PVC pipe with a bend to be provided in the concrete muffing for taking out cables. 8 x 75mm stainless steel Bolt & Nut shall be used for fixing all the flange covers. The post is to be painted with two coats of UV-resistant polyurethane paint of approved quality and color over two coats of best quality industrial epoxy primer and epoxy paint. All MS materials used for fabrication shall be dip galvanized. |
| 62 | OD3454/2025-2026:Supply of solar powered self contained and completely sealed extremely rugged robust with LEXAN(R) Polycarbonate UV stabilized body to withstand marine environment, LED Based Navigational aid having 3 to 5 NM + visibility range. The unit shall be water and weather proof conforming to protection class IP 68, signal colours compliant to IALA E-200-1, with maintenance free,12V, 12Ah SLA (sealed lead acid) battery capable of trouble free operation under 14 hours of darkness, 12.5% duty cycle, selection of all 310 IALA Flash patterns(user adjustable), multiple light intensity setings, 310 IALA Flash Characteristics and ON/OFF light levels, LED life expectancy>100000 hrs, automatic switching ON at dusk and automatic switching OFF at dawn, single LED light source and equivalent peak internsity red - 121 Cd, Green - 88 Cd, uniformity of output with intensity adustments in IR programmable. Horizonatal output 360 degree, vertical Divergence>7 degree, omni directional 360 degree High efficiency LED reflector with UV stabilized Poycarbonate LEXAN(R) lens. The unit shall have 4 hole bolt pattern on 200mm OD base for ease of installation and ambient temperature range. -30 degree to +50 degree Centigrade, water proof IP 68, monocrystalline tempered glass solar modules on four sides. The unit shall be set to the selected flash pattern as required at the supplier's risk. The manufacturer should possess ISO 9001:2015 and CE certifications EN61000-6-2:2005, IEC 61000-4-2"2008, IEC 61000-4-3:2010, IEC 61000-6-1:2016, IALA Signal colour compliant to IALAE-200-1. The entire unit shall have a warranty of 3 years(Preferred make Model SL-C310 Compact or equivalent) Solar lantern Red or Green colour |
| 63 | OD4163/2025-2026:Supply, installation, testing and commissioning (SITC) of outdoor landscape / garden LED Spike / Bush Light luminaire of system power rating 9 W, with high-efficiency LED optics engineered to provide directional spot lighting for landscape, foliage, and architectural accenting, delivering a minimum total initial luminous flux of 810 lumens (minimum efficacy 90 lm/w in Warm White / Neutral White color temperature 3000K- 4000.The fixture shall be constructed of heavy-duty pressure die-cast aluminium housing with high thermal conductivity, UV-stabilized corrosion-resistant powder coating, clear toughened optical glass lens cover, silicone rubber gaskets, providing ingress protection rating of IP65 / IP66 (completely dust-proof and water-jet resistant) and mechanical impact resistance IK07 / IK08.Complete with an internal / external high-efficiency constant-current electronic driver suitable for 230 V, 50\text{ Hz single-phase AC supply (Power Factor 0.90, Total Harmonic Distortion THD < 15%, Color Rendering Index CRI 80, surge protection minimum 2.5 kV, adjustable swivel tilt mounting head, heavy-duty metallic ground spike / mounting base plate, pre-wired 3-core outdoor grade rubber/PVC cable connection, earthing terminal, and all necessary mounting hardware and as directed by the Engineer-in-Charge. |
| 64 | OD4164/2025-2026:Supply, installation, testing and commissioning (SITC) of outdoor wall-surface mounted LED linear / spot Wall Washer luminaire of system power rating 10 W, delivering a minimum total initial luminous flux of 950 lumens (minimum system efficacy of 95lm/W in Warm White color temperature 2700 K 3000 K, with integrated / in-built high-efficiency LED module and optical lens arrangement designed specifically for uniform wall-washing and facade highlighting.The fixture shall be constructed from heavy-duty pressure die-cast / extruded aluminium housing with premium outdoor-grade weather-resistant powder coating, clear toughened optical glass cover, silicone rubber gaskets, providing an ingress protection rating of IP65 (completely dust-proof and water-jet resistant) and mechanical impact protection IK07 / IK08.Complete with an internal electronic driver operating on 230 V 50 Hz single-phase AC supply (Power Factor 0.90, Total Harmonic Distortion THD< 15\%, Color Rendering Index CRI 80, surge protection minimum 2.5 kV 4kV internal interconnections, adjustable mounting brackets / tilt mechanism, stainless steel (SS 304) external fasteners, earthing terminal, and all necessary masonry hardware fixings as directed by the Engineer-in-Charge. |
| 65 | OD4283/2025-2026:Supply, testing and delivery at site of heavy-duty, wall-mounted industrial switched socket-outlet box with mechanical interlock arrangement, rating 63 A, 415 V, 50 Hz AC, 5-pin configuration (3 Pole + Neutral + Earth / 3P+N+E), with ingress protection rating of IP67 (watertight / weatherproof) and mechanical impact protection IK08 / IK09.The unit shall feature an integrated heavy-duty rotary switch mechanically interlocked with the socket outlet such that the switch cannot be turned 'ON' unless the plug is fully inserted, and the plug cannot be withdrawn while the switch is in the 'ON' position. The switch handle shall be padlockable in the 'OFF' position for safety maintenance lock-out.Constructed from high-grade, self-extinguishing, chemical and UV-resistant thermoplastic / polycarbonate housing, complete with internal brass terminal blocks, nickel-plated contacts, heavy-duty continuous gasket, gland entry plate, earthing terminals, masonry fixings, and all required mounting accessories as directed by the Engineer-in-Charge. |
| 66 | OD4284/2025-2026:Supply and installation of wall mounting cubicle type dust and vermin proof , 600x300x214 mm, thermoplastic box including supply and fixing 250A, 35kA,4pole MCCB with BUC rotory drive kit , 230V ac shunt release ,ELR with CBCT including giving connection using 10.0 sq.mm pvc insulated copper wire, and 2A SPMCB with RYB indication lamp and wiring the circuit with 2.5 sqmm copper wire complete. |
| 67 | OD4341/2025-2026:Supply and installation of wall mounting cubicle type dust and vermin proof GRP hinged door type enclosure -IP66/IK 10 ,600 X 400 X 230 mm hinged type thermoplastic box with supply and fixing three numbers of 250A, HRC Fuse Base with HRC Fuse link and 100 A, 2 Way neutral links mounted on DMC/SMC base, 50/5 tape wound class 1 CT, 10VA, Confirmity IS 2705 /IEC 61869- 3 Nos . Sufficient holes for fixing energy meter. Necessary interconnection with suitable rated copper conductor with sockets are to be provided. work including all fixing accessories on wall and installation charges complete as required. |
| 68 | OD4618/2025-2026:Scraping, wire brushing, and thorough surface cleaning of existing metal surfaces of electrical panels, feeder pillars, distribution boards, and panel enclosures to completely remove rust, loose scale, oil, grease, dirt, and old flaking paint using mechanical wire brushes, emery paper, and solvent washing to achieve a smooth, clean metal substrate. Applying two coats of two-pack epoxy-based industrial primer (minimum dry film thickness / DFT of 35-40 microns per coat), followed by applying two coats of top-quality synthetic enamel paint of approved brand and shade (minimum DFT of 25-30 microns per coat) to achieve a uniform, smooth, corrosion-resistant gloss finish. Item includes necessary masking of meters, indicators, push buttons, lockable handles, rubber door gaskets, and rating plates, supply of all materials, labor, scaffolding, tools, equipment, solvent cleaning, and post-painting site cleanup, as directed by the Engineer-in-Charge |
| 69 | OD3152/2026-2027:Supplying and fixing following way, MCB distribution board, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, with PE+N terminals, thermoplastic circuit breaker boxes IP65 with metric knock out for cable entry, 3 row 36 module size 295 x 583 x 129 or nearest suitable size with PE+N terminals including earthing etc. as required. (But without MCB/RCCB/Isolator) 3 row 36 module with PE+N terminals complete . |
| 70 | OD4746/2025-2026:Supply and installation of wall mounting cubicle type dust and vermin proof 400 x 400 x 200 mm Glass Fibre Reinforced Polyester Enclosure with hinged door, IP66, IK 10 outdoor meterbox or equivalent with base plate for fixing KSEB meter, cut out & Neutral link and 20A , 10kA SPN MCB, C curve , with sufficient holes for fixing KSEB electronic energy meter, cut outs and neutral link. Supply and providing 1No 20A,10kA ,32A MCCB , 1 No 32A HRC fuse units with 20A HRC fuse link and 1No 32A 2way neutral link in the meter portion. Necessary holes are to be provided in the box for entry and exit of wire. The inter connection should be done using 4sq.mm copper wire. |
| 71 | OD3424/2025-2026:Fabricating, supplying, conveying, lifting, and erecting tubular post of overall height 11.70 m using 150mm and 125mm of Heavy-duty G.I. Pipe sections having ISI mark and of approved quality(TATA, ZENITH, APOLLO) as per the drawing erected on a RCC footing, using 1:2:4 CC with nominal reinforcement and 6 Nos. of PCC well steining having 0.9m dia and 0.30m height with a muffing of 0.6mx0.6mx1m and 8 numbers of 20mm dia 2.50m long MS foundation bolts having 150mm long standard thread on both ends and 3Nos 20mm and 2Nos 20mm nuts at the top and bottom for each bolt. The post is to be provided with a 20mm thick MS flange of OD 300mm with 8 nos of 20mm bolt holes and a base plate of 600mm square 10mm thick with 8 Nos 20mm dia bolt holes embedded in the concrete 1.8m below ground level. The post should have a 1500mm dia ringmade out of 50mm heavy GI pipe with cross supports using 40mm heavy GI pipe at the top for mounting the luminaries and its control gears. A 10mm thick MS flange having OD 300mm at 1200mm below the first ring mounted to the post. The top of the pipe should be sealed with 125mm table F Dummy flange. 12mm dia wire rope is to be provided for the entire length of the post as a mechanical support for the cables to the luminaries. Inverted Y arrangement using 50mm heavy GI pipe, flange, and dummy flange cover, and 75mm 4kgf/cm2 PVC pipe with a bend to be provided in the concrete muffing for taking out cables. 8 x 75mm stainless steel Bolt & Nut shall be used for fixing all the flange covers. The post is to be painted with two coats of UV-resistant polyurethane paint of approved quality and color over two coats of best quality industrial epoxy primer and epoxy paint. All MS materials used for fabrication shall be dip galvanized. |
| 72 | OD3153/2026-2027:Supply and installation of wall/structure-mounting cubicle type outdoor Thermoplastic Polycarbonate Mast Foot Box ,Size 4, 315 X 600 X 170mm with opaque/transparent hinged lid, degree of protection IP65/IP66, complete with internal base plate/DIN rails for accommodating 4-Pole RCCB, Isolator, and outgoing 2-Pole MCBs. Box shall include 4 Nos. 35sq.mm channel-mounted Elmex/equivalent terminal connectors suitable for looping up to 16 sq.mm aluminum armoured cables, tin-plated copper earth bus, and necessary IP-rated cable gland knockouts/holes for cable entry and exit. Internal interconnections shall be completed using 2.5 sq.mm flexible copper wiring with insulated pin/fork lugs. The mast foot box supply excludes RCCB and MCBs as required. |
| 73 | OD3422/2025-2026:Fabricating and supplying special clamping arrangement for fixing an asymmetrical beam integral LED flood light on 50 mm dia GI pipe ring with two clamps each made out of 50 x 6mm MS flat and 8x40mm SS nuts and bolts for one luminaire. The clamps are to be linked with 40x6mm MS flat with suitable holes 8mm,10mm, or 12mm size with suitable size SS Bolt& Nut to fix the luminaire. All the items are to be painted with two coats of epoxy-based industrial primer of approved quality and two coats of epoxy paint of approved color as per drawing. |
| 74 | OD4160/2025-2026:Supply, installation, testing and commissioning (SITC) of outdoor / indoor industrial type LED Highbay light luminaire of system power rating 100 W, with minimum system efficacy of 150 lumens/watt (total initial lumen output not less than 15,000 lm, complete with pressure die-cast aluminium housing for optimal thermal management and high corrosion resistance, UV-stabilized high impact resistance IK08 polycarbonate diffuser / optical lens cover, and suitable suspension eye-bolt / mounting bracket arrangement.The luminaire shall be engineered for operation under ambient temperatures ranging from -10C to +55C, operating on 230 V 50 Hz single-phase AC supply with an internal high-efficiency electronic driver (Power Factor > 0.95 , Total Harmonic Distortion THD} < 10 % , surge protection minimum 4 kV 6 kV , and ingress protection IP65 / IP66).Complete with internal wiring, earthing terminals, eye-bolts / suspension chains / mounting hardware, and all required accessories, as directed by the Engineer-in-Charge |
| 75 | OD3409/2025-2026:Supply and Laying of 1.1 kV grade 4 core 2.5 sq.mm PVC insulated and PVC sheathed / XLPE insulated, PVC sheathed, armoured copper conductor control cable through existing RCC / Hume / GI / PVC / metallic pipe or trench ducting, including uncoiling, pulling, clamping, and dressing.Item includes providing necessary drawing grips / pulling ropes, non-injurious cable lubricant, clamping with heavy-duty galvanized steel (GI) / aluminium saddles / spacers / MS flat clamps at suitable intervals, earthing of armouring at both ends, making necessary connections/terminations where required, and testing the cable for insulation resistance and continuity before and after laying, as directed by the Engineer-in-Charge. |
| 76 | OD3436/2025-2026:Supply, testing, laying and drawing of 1.1 kV grade 2 core 2.5 sq.mm PVC insulated, PVC sheathed / XLPE insulated, PVC sheathed, armoured / unarmoured copper conductor control cable through existing RCC / Hume / GI / PVC / metallic pipe or trench ducting, including uncoiling, pulling, clamping, and dressing.The cable shall feature stranded high-conductivity annealed copper conductors conforming to IS 1554 (Part 1) / IS 7098 (Part 1), color-coded core insulation, and a flame-retardant (FR / FRLS) outer sheath.Item includes drum handling, site delivery, factory test certificates (FTC), sequential length marking on outer sheath, providing necessary drawing grips / pulling ropes, non-injurious cable lubricant, sealing pipe ends post-pulling with weather-proof compound, clamping with heavy-duty galvanized steel (GI) / aluminium saddles / spacers at suitable intervals, earthing of armouring at both ends, making necessary connections/terminations where required, and testing the cable for insulation resistance and continuity before and after laying, as directed by the Engineer-in-Charge |
| 77 | OD3419/2025-2026:Supplying and making end termination with nickel-plated single compression brass cable gland for 1.1kV grade, 2 core 2.5 sq.mm PVC insulated, PVC sheathed, armoured copper conductor cable.Item includes providing heavy-duty nickel-plated brass cable gland complete with check nut, rubber sealing ring/gasket, PVC protective shroud, heavy-duty earth clamp / earthing ring/clip, compression type superior quality tinned copper cable lugs / sockets for both cores, crimping, insulating tape / heat-shrinkable sleeving, making necessary earth continuity connections using tinned copper tape/wire, and connecting the cable cores to switchgear / terminal block, as directed by the Engineer-in-Charge |
| 78 | OD3403/2025-2026:Supplying and making end termination with nickel-plated single compression brass cable gland for 1.1kV grade, 4 core 2.5 sq.mm PVC insulated, PVC sheathed, armoured copper conductor cable.Item includes providing heavy-duty nickel-plated brass cable gland complete with check nut, rubber sealing ring/gasket, PVC protective shroud, heavy-duty earth clamp / earthing ring/clip, compression type superior quality tinned copper cable lugs / sockets for all 4 cores, crimping, insulating tape / heat-shrinkable sleeving, making necessary earth continuity connections using tinned copper tape/wire, and connecting the cable cores to switchgear / terminal block, as directed by the Engineer-in-Charge. |
| 79 | OD3413/2025-2026:Supply and fixing cubicle type dust and vermin proof 300x600x170 mm, thermoplastic IP 65 junction box with lid including supplying and fixing 2 Nos 10 sq. mm 5pole terminal set for phases and neutral in the existing masonry cubicle fixing the following items, including giving connection using 4.0 sqmm, PVC insulated copper wire , drilling necessary holes for termination as well as entry and exit of cable, terminating the earth wire in the earth strip etc complete. Astrononical time switch suitable for 2 output perphase and suitable for single phase supply-1 NoRail mounting 415V ,9/11A, 3pole , 230V resin cast coil power contactor - 2 No10A ,TPMCB - 2 Nos (As Timer bypass)10A ,TPMCB - 2 Nos (As incomer to contactor) |
| 80 | OD3154/2026-2027:Supply and fixing Cable Junction Boxes IP 65 weather proof type for outdoor applications Thermoplastic Polycarbonate ) suitable for cable sizes 2.5 sq.mm , ,80 X 80X 52 mm and accessories for Cable Junction Boxes such as Copper Terminal Set 2.5 sq.mm 5 Pole 1 No,including fixing the accessories using suitable size Stainless steel Bolt and nut, giving necessary connections, making good the damages etc. as required . |
| 81 | OD3159/2026-2027:Supplying and fixing surface /recess mounting Vertical TPN distribution board with Double door , dust and water proof IP 66 Hensel make FP VN 0412 opaque or equivalent , 8+12 4 way DB of poly carbonate inclusive of tinned copper 250A busbar, common neutral link, earth bar,din bar for mounting MCB's with provision for MCCB as incomer. |
| 82 | OD3430/2025-2026:Supply and installation of wall mounting cubicle type dust and vermin proof , 600x300x214 mm, High lid thermoplastic box or equivalent with 25A,16 kA,TP MCCB with 32A 2 way porcelain neutral link and rotary handle , one set phase indication lamp,2A C-curve MCB - 3 Nos ,Panel surface mounting 96sq.mm backlit LED Multifunction meter three line display to read V,A,KVA,,PF and frequency of make Schneider or equivalent suitable for 415V ,50Hz - 1 No,30/5 tape wound class 1 CT -3 Nos. Sufficient holes for fixing phase indication lamp, multifunction meter and rotary handle in the thermoplastic box are to be provided. Necessary interconnection with suitably rated copper conductor with copper socket are to be provide. |
| 83 | OD3158/2026-2027:Supply and installation of wall mounting cubicle type dust and vermin proof 900 x 400 x 200 mm Glass Fibre Reinforced Polyester Enclosure with hinged door, IP66, IK 10 outdoor meter box or equivalent with base plate for fixing of KSEB meter, cut out &Neutral link and with sufficient holes for fixing KSEB electronic energy meter, cut outs and neutral link. Supply and providing 3 No 125A HRC fuse units with 100A HRC fuse link and 1No 125A 2way neutral link in the meter portion. Necessary holes are to be provided in the box for entry and exit of wire. Supply and fixing 125A, 35kA, 4 pole MCCB in the cubicle as per the drawing. The inter connection should be done using suitable size cable complete as required. |
| 84 | OD3155/2026-2027:Supply ,Installation, testing and commissioning of pre - wired, weather proof LED luminaire IP65 rated having power consumption of 34 /40 W and light output not less than 2100 lm with system efficiency >120 lumens/watt. Luminaire housing made from superior quality of polycarbonate extrusion IP65 and and IK 08 protection. The luminaire should be having minimum 30000 Burning hours with CRI >=80 and co related colour temperature(CCT)of 6500K. of all types, complete with all accessories etc. directly on ceiling/ wall, including connection with 1.5 sq.mm FRLS PVC insulated, copper conductor, single core cable and earthing etc. as required. |
| 85 | OD3156/2026-2027:Supplying and fixing of following ways surface/ recess mounting, vertical type, 415 volts, TPN MCB distribution board of Vertical TPN DB - IP65, Weather proof Polycarbonate , dust protected, , inclusive of 125 amps tinned copper bus bar, common neutral link, earth bar, din bar for mounting MMCB's (but without MCB's and incomer ) as required .(Note : Vertical type MCB TPDB is normally used where 3 phase outlets are required.)8 Way including all accessories complete as required. |
| 86 | 90.15.2.4:Supply installation testing and commissioning of High Mast using Octogaonal Pole made single/two sections of hot dip galvanised GI sheet 150mm top diameter, 360mm bottom diameter thickness 3mm mm suitable for wind speed as per IS 875 Part III with head frame assembly two point suspension system with steel wire rope 5mm dia double drum winching system w and including round arm galvanized luminary carriage suitable to install 6/8 nos luminaries in symmetrical arrangement control gear box and lighting spikes with single phase operation power tool installed inside the base compartment including connector foundation bolt 6 nos fixed in existing RCC foundation and junction box etc, complete 16 Meters |
| 87 | Civil Work |
| 88 | 5.22.1:Steel reinforcement for R.C.C work including straightening, cutting, bending, placing in position and binding all complete upto plinth levelMild steel and Medium Tensile steel bars |
| 89 | 15.2.2:Demolishing cement concrete manually / by mechanical means including disposal of material within 50 metres lead as per direction of Engineer - in-Charge.Nominal concrete 1:4:8 or leaner mix ( including equivalent design mix) Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Tender Published
Tender notice published.
CompletedBid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 7 daysBid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 9 daysTender Documents
Download All (ZIP) ↓We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender