Tender For Periodical And Emergent Electricial Maintenance Under Jurisdiction Of K.C. Div No-I Amlagora & Its Sub Divs, Sectio Offices, Colonys Etc Under The Jurisdiction Of Kmd During The Year Of 2026-27.
Tender Value
9.89 Lakhs
Estimated cost
Bid Submission
10 Aug 2026
13 days left
EMD
19784
Bank guarantee accepted
Document Fee
Ref. Documents
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Medinipur West → West Bengal
EMD Exemption
Not Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender for Periodical And Emergent Electricial Maintenance Under Jurisdiction Of K.C. Div No-I Amlagora & Its Sub Divs, Sectio Offices, Colonys Etc Under The Jurisdiction Of Kmd During The Year Of 2026-27.
BOQ
| Sl. No. | Item Description |
| 1 | Emergent Electrical maintenance work as & when required basis under the jurisdiction of K.C. Div No-I Amlagora & its Sub Div's at Salbani, Sarenga, Sectio offices, colony etc. under the jurisdiction of KMD. |
| 2 | a) Electrican |
| 3 | b)Helper for Electrician |
| 4 | Periodical and Emergent electricial maintenance work and pump operation for one year under jurisdiction of under the jurisdiction of K.C. Div No-I Amlagora & its Sub Div's at Salbani, Sarenga, Sectio offices, colony etc. under the jurisdiction of KMD. |
| 5 | a) Electrican |
| 6 | b)Helper for Electrician |
| 7 | Supplying of 1200 mm approved make high speed ceiling fan (ISI marked) of following sizes having double ball bearing complete with standard down rod, canopy, hanging shackle, Aluminium blades, without regulator, A.C. 230-250volts, Usha Strikar Neo/ any approved make. |
| 8 | Opening the Ceiling fan testing, checking and Re-winding by supplying super enamelled copper wire of appropriate gauge, minilex paper, mica sheet, changing the loops, overhauling, backing, varnishing, re-fitting and using and measuring r.p.m. for ceiling fan above 36\\" sweep up to 60\\" sweep. |
| 9 | Supplying following sizes Capacitor of 250V rating: 2.5 MFD Capacitor (Tibcon/Universal Make or equivalent). |
| 10 | Supply Philips LED tube, model no : Mas LEDtube 1200mm 18W865 T8 I - 2100lm, |
| 11 | Supply of 2X20 T8 tube holder alongwith 2 nos. 20 Watt T8 LED Tubes Specification T8 LED Tube , CCT-6500K, Lumen-2200, Make-Magik/ any, approved make . |
| 12 | Supply and fixing of smart bright essential street light complete with all accessories to be fixed / projected from the wall of the building or on pole incl. making holes/ providing clamping arrangement & necy. GI reducer as required. S&F 40mm GI pipe (ISI-Medium) quality 1.5 mts. average length having suitable bend S&F necy. length of 1.5 sqmm PVC insulated single core stranded annealed copper wire and making connections as required and mending good damages to wall incl. painting etc. 72 watt with Toughend glass , 130 lm/w, Spd 15 kva at least and 5 years warrenty etc, Surya/ Crompton make. |
| 13 | Supply of Havells make, NU Bulb Plus 9W 865 B22 3 Star, |
| 14 | Supply of 6.0 sqmm 'FR' stranded Copper wire, polycab/ Gloster /finolex, |
| 15 | Supply of 1.5 sq.mm 'FR' stranded Copper Wire, Polycab/Gloster/finolex . |
| 16 | Supply of 2.5 sqmm'FR' stranded Copper Wire Polycab/Gloster/finolex . |
| 17 | Supply of 5 A, piano key type Switch , Anchor/ havells . |
| 18 | Supply 5 A, 3 pin Piano flush type Socket, Anchor/ havells . |
| 19 | Supply of Step Type Electronics Fan regulator, Anchor/ havells , |
| 20 | Supply of 16A kit kat rewireable fuse, havells/standerd/flora, |
| 21 | Supply of ammeter selector switch Current in Each phase with OFF, 4 Pos. 90° angle of throw (OFF-R-Y-B), |
| 22 | Supply of voltmeter selector switch Votage between phases with OFF, 4 Pos. 90° angle of throw (OFF-RY-YB-BR), |
| 23 | Supply of 22.5 mm Hole Dia Mushroom Type Push Button, |
| 24 | Supply of 22.5 mm dia LED indicating lamps (red,yellow, blue), |
| 25 | Supply of 240VAC analog time switch for ON-OFF control of street light, L&t/Legrand make. |
| 26 | Supply of 3 pole power contactor type ML 2, 40A current rating , L&t/Legrand make. |
| 27 | Supplying of approved make exhaust fan heavy duty with mounting frame, blades AC 230-250. 225mm sweep RPM 9001 1400(9\\") , EPC/Crompton make. |
| 28 | Opening the following Exhaust fan (1 Phase/3 Phase) /Stand Fan/Cabin Fan testing, checking, Re-winding by supplying super enamelled copper wire of appropriate gauge, minalex paper, mica sheet, changing the loops, overhauling, becking, varnishing, re-fitting and testing and measuring r.p.m. etc.Cabin Fan (16\\" or 40 em, dia sweep), |
| 29 | Properly checking of the motor ( upto 75 HP), testing of developed IR value, load current factor, terminal lead joints, terminal bar etc. necessary repairing works. |
| 30 | Supply and delivery of direct on line ( DOL) strater panel board conforming to ISl3947 and IEC 947 of suitable HP rating for operation in 230V (+10%) AC, single phase, 50HZ(+5yo) comprising of ammeter, voltmeter, thermal overload relay,2 pole magnetic contactor, under voltage protection, indicating lamp, capacitors, on/off push buttons including 5 way connector, wiring with l/1.5 sq. mm PVC insulated copper wire, powder coated vermin proof box of following capacities:- 1.5 H.P. (Relay Range 9-14 Amp.) |
| 31 | Supply of 20/25A socket, Achor/havells make. |
| 32 | Supply of 20/25A plug top Achor/havells make. |
| 33 | Supplying and fixing Sheet steel Main Switches on flat iron frame on wall, 240V DP with fuse on L&N 30/32 A Anchor make, |
| 34 | Supplying & Fixing 240 V AC/DC superior type Ding-DongCall Bell (Anchor) on HW board incl. S&F HW board, Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Jul 27, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedAug 10, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 13 daysAug 11, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 14 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender