Tender for Repair / Maintenance To Internal Electrification Incl Ceiling Fan, Exhaust Fan, Geysers And Connected Works In Md Accn Np Area And 9 P&S Unit And Ug Cable, Lt Panel And Connected Works At 9 P&S Unit And Narendra Place At Afs Tambaram (8927/E8)
BOQ
| Sl. No. | Item Description |
| 1 | Taking down carefully copper/aluminum point wiring (light, fan, socket or power) complete and making good disturbed surface of wall, floors etc complete all as specified and directed by Engineer-in-Charge. |
| 2 | Point wiring complete with 1.50 sqmm single core PVC FRLS insulated sheathed 1100 volts grade copper conductor single core multi stranded drawn through with and including non metallic rigid PVC conduit accessories concealed on walls, suface on ceiling etc., with suitable clamps/ shaddles, including provision of 1.6 mm thick MS pressed steel terminal boxs concelled/surface in wall with suitable modular white cover plate with frame for housing switiches, sockets, fan regulators etc., including one run of 1.50 sqmm PVC insulated copper conductor for continious earth wire and connected to common earth dolly for the following complete all as specified and directed by Engineer-in-Charge.:- |
| 3 | All as per Item No 2 above for One light /fan point controlled by one 5 Amps switch. |
| 4 | All as per Item No 2 above for One light point controlled by two 5 Amps Two way switches. |
| 5 | All as per Item No 2 above but for One 3 pin 5 Amps socket outlet on same board. |
| 6 | All as per Item No 2 above but for One 3 pin 5 Amps socket outlet on independent board. |
| 7 | All as per Item No 2 above but for One call bell point controlled by one bell push. |
| 8 | All as per item No 2 above but for one 3 pin socket outlet 15 Amps independent with cable 2.5 Sq mm size. |
| 9 | All as per item No 2 above but for one 3 pin socket outlet 15 Amps independent with cable 4 Sq mm size. |
| 10 | M&L for Point wiring complete with 1.50 sqmm single core PVC FRLS insulated sheathed 1100 volts grade copper conductor single core multi stranded drawn through with and including PVC casing & caping/PVC conduit on walls, suface on ceiling etc., with suitable clamps/ shaddles, including provision of 1.6 mm thick MS pressed steel terminal boxs concelled in wall with 3 mm thick hylam sheet for housing switiches, sockets, fan regulators etc., including one run of 1.50 sqmm PVC insulated copper conductor for continious earth wire and connected to common earth dolly for the following complete all as specified and directed by Engineer-in-Charge. :- |
| 11 | All as per Item No 10 above for One light point/fan point controlled by one 5 Amps switch complete all as specified and directed by Engineer-in-Charge. |
| 12 | All as per Item No 10 above but for One 3 pin 5 Amps socket outlet on same board complete all as specified and directed by Engineer-in-Charge. |
| 13 | All as per Item No 10 above but for One 3 pin 5 Amps socket outlet on independent board complete all as specified and directed by Engineer-in-Charge. |
| 14 | All as per Item No 10 One 3 pin 5 Amps socket outlet independent but below the switch board of light points in the same vertical plane, with cables, 1.5 sq. mm size complete all as specified and directed by Engineer-in-Charge. |
| 15 | All as per Item No 10 above but for One call bell point controlled by one bell push complete all as specified and directed by Engineer-in-Charge. |
| 16 | All as per item No 10 above but for one 3 pin socket outlet 15 Amps independent with cable 2.5 Sq mm size complete all as specified and directed by Engineer-in-Charge. |
| 17 | All as per item No 10 above but for one 3 pin socket outlet 15 Amps independent with cable 4 Sq mm size complete all as specified and directed by Engineer-in-Charge. |
| 18 | Material & Labour for attending No supply /short circuit /checking of ups supply other electrical complaints and make serviceable all as specified and as directed.Note :- (i) complaint received from complaint cell (ii) required tools provided by contractor (iii) The rate quoted is deemed to included for insulation tape, wires /cable complete all as specified and directed by Engineer-in-ChargeNote: Complaint not completed with 24 hrs Recovery made as per PS. |
| 19 | Taking down and Supply and fix the Modular switch 1 way 6A,1 module including disconecting, removing, and connecting into electric circuit complete all as specified and directed by Engineer-in-Charge. |
| 20 | All as per Item No.19 above but for Modular switch 1 way 16A, 1 module complete all as specified and directed by Engineer-in-Charge. |
| 21 | All as per Item No.19 above but for Modular socket 6A 3 pin combined 2 module complete all as specified and directed by Engineer-in-Charge. |
| 22 | All as per Item No.19 above but for Modular socket 6A/16A 2/3 pin combined 2 module complete all as specified and directed by Engineer-in-Charge. |
| 23 | All as per Item No.19 above but for Modular Fan regulator 120 W 2 Module suitable for 1200mm/1400mm sweep fan complete all as specified and directed by Engineer-in-Charge. |
| 24 | All as per Item No.19 above but for Switch piano flush type 5 Amps ,Single pole one way complete all as specified and directed by Engineer-in-Charge. |
| 25 | All as per Item No.19 above but for Switch socket flush type 2 in 1, 3 pin 5 Amps 240 V complete all as specified and directed by Engineer-in-Charge. |
| 26 | All as per Item No.19 above but for Switch socket combination 2 in 1, 3 pin 5 and 15 Amps flush type universal complete all as specified and directed by Engineer-in-Charge. |
| 27 | All as per Item No.19 above but for Fan regulator stepped type electronic flush/switch type, suitable for 1200mm /1400 mm sweep fan complete all as specified and directed by Engineer-in-Charge. |
| 28 | All as per Item No.19 above but for PVC ceiling rose two to three terminal plate and jumbo type complete all as specified and directed by Engineer-in-Charge. |
| 29 | All as per Item No.19 above but for Lamp holder, PVC/Polycarbonate type with back plate suitable for batten fittings complete all as specified and directed by Engineer-in-Charge. |
| 30 | All as per Item No.19 above but for Bell push Flush type 5 Amps all as specified and as direcetd complete all as specified and directed by Engineer-in-Charge. |
| 31 | All as per Item No.19 above but for Call bell 230 volts single pole A/C multimusic fancy type ding dong bell complete all as specified and directed by Engineer-in-Charge. |
| 32 | Taking down and Supply and fix in replacement of laminated hyleum sheet 3 mm thick as per site required sie of 4''x4'' including cutting holes for fixing the switches /sockets etc and transfering all the switches/sockets including disconnecting and reconnecting into electric circuit and testing complete all as specified and directed by Engineer-in-Charge. |
| 33 | Taking down and Supply and fix in replacement of laminated hyleum sheet 3 mm thick as per site required sie of 6''x8'' including cutting holes for fixing the switches /sockets etc and transfering all the switches/sockets including disconnecting and reconnecting into electric circuit and testing complete all as specified and directed by Engineer-in-Charge. |
| 34 | Taking down and Supply and fix in replacement of laminated hyleum sheet 3 mm thick as per site required sie of 12\\"x8'' including cutting holes for fixing the switches /sockets etc and transfering all the switches/sockets including disconnecting and reconnecting into electric circuit and testing complete all as specified and directed by Engineer-in-Charge. |
| 35 | Taking down and Supply and fix, in replacement, of MCB DB SPN double door, 4 way 240 V neutral link, earth link complete all as specified and directed by Engineer-in-Charge. |
| 36 | Taking down and Supply and fix, in replacement of MCB DB SPN, double door, 8 way 240 V with 200 A rated bus bar neutral link, earth link complete all as specified and directed by Engineer-in-Charge. |
| 37 | Taking down and Supply and fix in replacement for MCB DB TPN 4 way vertical type double door complete including 200A rated copper bus bar, and netral and earth link suitable with MCB TPN as incommer complete all as specified and directed by Engineer-in-Charge. |
| 38 | Taking down and Supply and fix in replacement for MCB DB TPN 8 way vertical type double door complete including 200A rated copper bus bar, and netral and earth link suitable with MCB TPN as incommer complete all as specified and directed by Engineer-in-Charge. |
| 39 | Taking down and Supply & fixing of Vertical type sheet metal enclosure MCB DB TPN 4 ways double door type including 125 Amps MCCB 4 Pole 415 V,16 KA incomer with suitable bus bar surface/concealed on wall and connecting with all connections complete all as specified and directed by Engineer-in-Charge. |
| 40 | Taking down and supply and fixing in replacement for MCB SP 06 to 32 Amps, 10KA 240 volts,50Hz complete all as specified and directed by Engineer-in-Charge. |
| 41 | Taking down and supply and fixing in replacement of MCB SPN 05 to 40 Amps 10KA 240 volts complete all as specified and directed by Engineer-in-Charge. |
| 42 | Taking down and supply and fixing in replacement of MCB TP 63 Amps 10KA 415 volts complete all as specified and directed by Engineer-in-Charge. |
| 43 | Taking down and supply and fix in replacement of MCB TPN 63 Amps 10KA 415 volts complete all as specified and directed by Engineer-in-Charge. |
| 44 | Taking down and supply and fix in replacement of MCB TP 100 Amps 10KA 415 volts complete all as specified and directed by Engineer-in-Charge. |
| 45 | Taking down and supply and fix in replacement of Single pole and neutral enclosure with two pin and earth plug and socket complete with one single pole MCB 20 Amp 240 Volts complete all as specified and directed by Engineer-in-Charge. |
| 46 | Taking down and supply and fix in replacement of MCCB 25 to 100 Amp 3/4 pole 16 KA breaking capacity 415 Volts complete all as specified and directed by Engineer-in-Charge. |
| 47 | Taking down existing sub main wiring any description along with PVC conduit/ casing capping and made good the disturbed surface complete all as specified and directed by Engineer-in-Charge. |
| 48 | M & L for circuit/sub main wiring complete with 2 X 2.5 Sqmm single core FRLS PVC insulated unsheathed cable 1100 volts grade with multistranded copper conductor drawn through existing surface/recessed steel/PVC conduit and accessories with 1 X 2.5 Sqmm of PVC FRLS copper cable for earth continuity all as specified, dismantling existing circuit/ sub main wiring and making good disturbed portion complete all as specified and directed by Engineer-in-Charge. |
| 49 | M & L for circuit/sub main wiring complete with 2 X 4 Sqmm single core FRLS PVC insulated unsheathed cable 1100 volts grade with multistranded copper conductor drawn through PVC conduit and accessories on surface of wall roofs etc with 1 X 4 Sqmm of PVC FRLS copper cable for earth continuity all as specified , dismantling existing circuit/ sub main wiring and making good disturbed portion complete all as specified and directed by Engineer-in-Charge. |
| 50 | M & L for circuit/sub main wiring complete with 2 X 6 Sqmm single core FRLS PVC insulated unsheathed cable 1100 volts grade with multistranded copper conductor drawn through PVC conduit and accessories on surface of wall roofs etc with 1 X 6 Sqmm of PVC FRLS copper cable for earth continuity all as specified , dismantling existing circuit/ sub main wiring and making good disturbed portion complete all as specified and directed by Engineer-in-Charge. Note for Sl items No.48 to 50 : Two runs of cable and one run of earth continuity cable shall be measured as one unit. |
| 51 | M & L for circuit/sub main wiring complete with 4 X 4 Sqmm single core FRLS PVC insulated unsheathed cable 1100 volts grade with multistranded copper conductor drawn through suitable size PVC conduit and accessories on surface of wall roofs etc with 1 X 4 Sqmm of PVC FRLS copper cable for earth continuity all as specified , dismantling existing circuit/ sub main wiring and making good disturbed portion complete all as specified and directed by Engineer-in-Charge. |
| 52 | M & L for circuit/sub main wiring complete with 4 X 6 Sqmm single core FRLS PVC insulated unsheathed cable 1100 volts grade with multistranded copper conductor drawn through suitable size PVC conduit and accessories on surface of wall roofs etc with 1 X 6 Sqmm of PVC FRLS copper cable for earth continuity all as specified , dismantling existing circuit/ sub main wiring and making good disturbed portion complete all as specified and directed by Engineer-in-Charge. |
| 53 | All as per item No.30 here in before but for 4 x 10 Sqmm conductor with 1 x 10 Sqmm as earth continuity copper conductor complete all as specified and directed by Engineer-in-Charge. Note for Sl items No.51 to 53 : four runs of cable and one run of earth continuity cable shall be measured as one unit. |
| 54 | Taking down old light fitting and S & F in replacement of Wall mounted light fitting LED batten, extruded heat sink provided for effcient heat dissipation & integrated electronic driver with 20 W LED 6500K (4 ft) lamp including disconecting, removing, and connecting into electric circuit and testing complete all as specified and directed by Engineer-in-Charge. |
| 55 | Taking down old light fitting and Supply and fix in replacement surface and wall mounted 10 Watt LED batten, provided for efficient heat dissipation with polycarbonate diffuser & intergrated electronic driver including LED lamp complete all as specified and directed by Engineer-in-Charge. . |
| 56 | Taking down old light fitting and S&F in replacement of security light fitting LED luminares New generation energy saving & environmental friendly long life versatile pressure die-cast aluminium IP65 roadway luminaire with high power LED as light source with 35 W LED 5000K lamp including disconecting, removing, and connecting into electric circuit including testing complete all as specified and directed by Engineer-in-Charge. |
| 57 | M&L GI Bracket bend to shape in cold or hot 40mm bore medium grade and 1.50 M long with suitable MS clamps and nuts bolts etc, to fixing security light fittings to Bldgs complete after taking down the unsv GI bracket complete all as specified and directed by Engineer-in-Charge. |
| 58 | Supply and fix in replacement RUGBY GENX 10 watt (Bulk head fitting) designed with beautiful asesthetics using new generation techonology in LED to enliven your outdoor and indoor area in perfect synchronization with functionality and aesthetics.family of bulked lights designed to completement the geometry of the area with modern design complete all as specified and directed by Engineer-in-Charge. . |
| 59 | S&F Decorative LED wall light fitting stainless steel,rust free fixture with white glass diffuser including 15 W LED lamp complete complete all as specified and directed by Engineer-in-Charge. |
| 60 | S&F LED Lamp 9W complete all as specified and directed by Engineer-in-Charge. |
| 61 | S&F in replacemnt of post top 30 Watt light fittings LED luminaire CORAL LED post top new generation IP 65 led post of family,energy saving, environmental friendly,long life aesthetically designed with symertical light distrubution,spun aluminium landscap luminaire with high power LEDs as light source.Opal cover offers soothing uniform illumination for different applications complete all as specified and directed by Engineer-in-Charge. |
| 62 | M&L for earthing complete with galvanized steel earth plate electrode 600X600X6mm thick buried directly in ground (earth pit not less than 2.25m deep below normal ground level) with top edge of the plate not less than 1.5M below normal ground level connected to GI earth lead wire 4.0mmdia by means of nuts, bolts, check nuts and washer of GI steel and connecting to testing point including provision of test point and all as shown in electrical plate No. 3 of SSR Pt I. The work shall inclusive of necessary earth work and PCC chamber 1:3:6 in type CI with 8mm CTD bar reinforcement both ways at 140 mm bents to centre complete all as specified and directed by Engineer-in-Charge, including taking down old unserviceable earthing . |
| 63 | Supply and laying XLPE insulated screened PVC bedded galvanised steel strip or wire armoured electric cable(heavy duty) with aluminium conductor 1100 volts grade cross sectional area 2 core 6 sq mm in trenches/on truss/wall/floor through pipe with MS clamps complete all as specified and directed by Engineer-in-Charge. |
| 64 | Material and labour for Weather proof flat twin core cable of size 4 sqmm including suitable PVC Conduit complete all as specified and directed by Engineer-in-Charge. |
| 65 | Taking down carefully Existing ceiling fan/exhaust fan/wall Mounted fan/pedestal/Air circulator fan of any size/ Make after disconnecting the electrical connection etc.complete all as specified and directed by Engineer-in-Charge. |
| 66 | Refixing/Instal only ceiling fan any size/make replacing the spares such as carter pin Unserviceable/Rusted nut bolts,split pin rubber wheel bearing washers,bush,PVC clamps for holdings of capacitor, etc.And connecting up with PVC insulated cable size 1.5 Sqmm three core copper conductor round cable complete complete all as specified and directed by Engineer-in-Charge. (Note:- Rewinding,spare parts such as ball bearing, capacitor,bush etc required to make the ceiling fan serviceable shall be measured paid seperately under relevent items. .The Refixing fan shall be tested after fixing the blades) |
| 67 | Refixing /Install only Exhaust/Pedestal/Wall Mounted/aircirculator fans along with louvers any description any approval make, replacing the spares such as carter pin Unserviceable /Rusted nut bolts,split pin rubber wheel bearing washers,bush,PVC clamps for holdings of capacitor etc.And connecting up with PVC insulated cable size 1.5 Sqmm three core copper conductor round cable complete all as specified and directed by Engineer-in-Charge. (Note:- Rewinding,spare parts such as ball bearing, capacitor,bush etc required to make the ceiling fan serviceable shall be measured paid seperately under relevent items. .The Refixing fan shall be tested after fixing the blades) |
| 68 | Material and labour for rewinding of fan motor with super enameled copper winding wire of same gauge and weight after cutting and removeing the existing burnt/heated up windings,including cleaning of rotor and varnishing,heating and providing fresh insulating Materials for the following size of fans/circulators :-( a ) Exhaust fan225 to 300 mm Sweep complete all as specified and directed by Engineer-in-Charge. |
| 69 | (b) Exhaust Fan 350 to 450mm Sweep |
| 70 | (c ) Ceiling fan of any sweep |
| 71 | Taking down US ceiling fan handover MES Store for BER process and Supply and fixing ceiling fans complete with blades, down rods, and accessories, 230 V, 1200 mm sweep. Five star rated with brushless direct current motor (BLDC) complete all as specified and directed by Engineer-in-Charge. |
| 72 | Taking down US Ex-fan fan handover MES Store for BER process and Supply and fixing exhaust fan, steel body AC single Phase. 230V of size 300m sweep with, blades, and frame and louvers. complete all as specified and directed by Engineer-in-Charge. |
| 73 | Taking down US Ex-fan handover MES Store for BER process and Supply and fixing exhaust fan made of sturdy Engineering plastic complete with louvers shutter, voltage 230V, 50 Hz, RPM 1200, Copper winding of sweep 300/250mm complete all as specified and directed by Engineer-in-Charge. |
| 74 | Supply only ball bearing size (6201/6202/6203) suitable for ceiling fans size 1200/1400 mm Sweep complete all as specified and directed by Engineer-in-Charge. |
| 75 | Supply only ball bearing Size (2001/2002/2003) suitable for exhaust/wallfan of any size and complete all as specified and directed by Engineer-in-Charge. |
| 76 | supply only capcitor of capacity 2.5 mfd for the fans in position complete all as specified and directed by Engineer-in-Charge. |
| 77 | supply only capcitor of capacity 4 mfd for the fans in position complete all as specified and directed by Engineer-in-Charge. |
| 78 | supply only GM bush suitable for ceiling fan of size 1200/1400 mm Sweep complete all as specified and directed by Engineer-in-Charge. |
| 79 | supply only bush suitable for exhaust fans any complete all as specified and directed by Engineer-in-Charge. |
| 80 | supply only BLDC ceiling fan PCB board convertible 240 Volt AC to 12 Volt DC suitable for any type/model ceiling fan 1200 mm sweep 230 Volt 50 Hz complete all as specified and directed by Engineer-in-Charge. |
| 81 | Material & labour for Cleaning and preparing the surface of ceiling fan of any sweep, removing the grease,carbon dust over the fans,filling cavities with filler and applying one coat synthetic enamel paint painting of ceiling fan with down rod upto 2.00 mtr long with two coats of synthetic enamel white paint of approved colour by spraying including preparation of old painted surface & writing of MES No on the fan complete all as specified and directed by Engineer-in-Charge. |
| 82 | Material & labour for Cleaning and preparing the surface of exhaust /wall mounted /pedestal/Air circulated any sweep, removing the grease,carbon dust over the fans,filling cavities with filler and applying exisiting colour by synthetic enamel paint of approved colour by spraying including writing of MES No on the fan complete all as specified and directed by Engineer-in-Charge. |
| 83 | Taking down carefully storage type water heater (Geyser)of any type and make up to 25 /50 Ltrs capacity after disconnecting all Electrical connecting,descaling the inner container heating element base assembly etc by using diluted hydrochloric acid and cleanning thoroughly,filling the inner container with water and checking leakage if any reasembling the geyser after of leakage by bracing and electric and water supply lines,refixing and testing on completion complete all as specified and directed by Engineer-in-Charge. (Note:-spares shall be measured and paid saperately under relevent items of this Schedule) |
| 84 | supply only Heating Elementswith rubber gasket thread/push type 230V,2.0/1.5 KW complete all as specified and directed by Engineer-in-Charge. |
| 85 | supply only Thermostart suitable for Geysers 25 to 50 Ltrs capasity,and temp range 30 to 80 degree centigrade and cut off at 70 degree centigrade complete all as specified and directed by Engineer-in-Charge. |
| 86 | supply only 4 sqmm flexible industrial wire for water heater complete all as specified and directed by Engineer-in-Charge. |
| 87 | supply and fix in replacement 3 pin plug top 16 Amp complete all as specified and directed by Engineer-in-Charge. |
| 88 | supply and fix PVC Connecting pipe 15 mm dia 450 mm long heavy duty suitable for hot/cold water with two brass union and washers complete all as specified and directed by Engineer-in-Charge. |
| 89 | M&L for servicing to indoor/outdoor LT panel board installed at AFS Tambaram, opening up all cubical doors, cleaning with air blower, removing the burnt out unserviceable instruments, copper wiring kit, and burnt out unserviceable extented copper terminals/ copper cable and replacing with new copper extented terminal bus bar with suitable size along with required nut bolt, washers, and replacing the measuring instruments like Ammeter with existing size of the CT, Volt meter, indicating lamps of LED type 'R Y B' cleaning with CTC to serviceable parts like MCCB's, all terminals, replacement of damaged aluminum lugs any description of LT U/G cables in coming and out going, welding of broken door with suitable hinges, replacement of deterioated copper wiring with suitable copper conductor with circuit indicator replacement of sheared rubber beadings to door of panels, including preparing the existing surface for spray painting to powder coated surface with two coat of synthetic enameled paint of approved colour, marking of incoming and out going feeder with fluorecent stickers incl preparation of the surface of panel complete all as specified and directed by Engineer-in-Charge. |
| 90 | Supply only following items :- ( a) Volt meter digital type 0-500 Volts |
| 91 | (b) Ammeter digital type suitable to 0 - 500 Amps |
| 92 | ( c) Aluminum lugs suitable for70 sqmm to 150 sqmm cables |
| 93 | (d) Aluminum lugs suitable for 185 to 300 sqmm cables |
| 94 | (e) Aluminum lugs suitable for 25 sqmm to 50 sqmm cables |
| 95 | (f) Indicator lamp LED type 'R,Y,B' |
| 96 | (g) CT coil size 4x4 ratio 100/5 Amps |
| 97 | Material and labour for welding in repairs n exc 2.5cm in length n exc 6m thickness of metal of metal to be welded complete all as specified and directed by Engineer-in-Charge.NOTE : The rate quoted is inclucve of Hinges/ lock etc any other accessories . |
| 98 | Excavation in trenches not exceeding 1.5 mtr deep and not exceeding 1.5 mtr wide and getting out in hard/dense soil for all complete all as specified and directed by Engineer-in-Charge. |
| 99 | Returning and refilling of excavated soil upto a depth of 30 cm after riddling the excavated soil for laying underground cables and post holes complete all as specified and directed by Engineer-in-Charge. |
| 100 | Removal of surplus soil to a distance not exceeding 50 mtr and depositing where directed at a level not exceeding 1.5 mtr above the starting point complete all as specified and directed by Engineer-in-Charge. |
| 101 | M & L for brick protection to cable using old size sub class 'B' bricks, laidflat, dry butt jointed, laid lengthwise perpendicular to the axis of cable complete all as specified and directed by Engineer-in-Charge. |
| 102 | Relaying of old serviceable bricks of any size removed from old cable trenches laid across trenches for cable protection complete all as specified and directed by Engineer-in-Charge. |
| 103 | M & L for cutting Bitumen macadam / concret foot path to a depth 0.75 mm with suitable mechanical cutter making good with cement concrete 1 : 2: 4 type B1 ( 20mm graded aggregate ) complete all as specified and directed by Engineer-in-Charge. |
| 104 | Material and labour for cable jointing kit for 1.1 KV (Earthed) grade cable for straight through heat shrink type joint complete with jointing material and accessories suitable for 3 .5 core XLPE armoured aluminium conductor cable of size 6 sqmm to 16 sqmm complete all as specified and directed by Engineer-in-Charge. |
| 105 | All as per Item No.97 above but for 3.50 core cable 25 to 50 Sq mm. |
| 106 | All as per Item No.97 above but for 3.50 core cable 70 to 120 Sq mm. |
| 107 | All as per Item No.97 above but for 3.50 core cable 150 to 185 Sq mm. |
| 108 | All as per Item No. 97 above but for 3.50 core cable 240 to 300 Sq mm. |
| 109 | Cutting removing the vegetation growth and surface dressing all around the installation yard including 4/2 pole structure area to keep the installation area (external only) clean and tidy complete all as specified and directed by Engineer-in-Charge. |
| 110 | Supply, Laying testing and commissioning of LT UG cable 1100 Volts grade XLPE insulated PVC sheathed amoured, heavy duty, in trenches/walls/poles/passing through pipes with multistranded aluminium conductor including lugs/thimble/ferules connection complete including taking out old unserviceable UG cable for the following sizes complete all as specified and directed by Engineer-in-Charge.. Note: Earth work shall be measured nd paid separately. [a]16 sqmm 2 core |
| 111 | [b]16 sqmm 4 core |
| 112 | [c] 25 sqmm 3.5/4 core |
| 113 | [d] 50 sqmm 3.50 core |
| 114 | [e]70 sqmm 3.50 core |
| 115 | [f] 95 sqmm 3.50 core |
| 116 | [g]120 sqmm 3.5 core |
| 117 | [h] 185 sqmm 3.50 core |
| 118 | [i] 240 sqmm 3.50 core |
| 119 | [j] 400 sqmm 3.50 core |
| 120 | Taking out the existing any description of LT UG cable and find out the fault and re-laying of the same LT UG cable in trenches/walls/poles/passing through pipes with new lugs/thimble/ferules connection, testing and commissioning complete all as specified and directed by Engineer-in-Charge.Note: Earth work shall be measured nd paid separately. (a) 10 sqmm to 16 sqmm 4 core |
| 121 | (b) 16 sqmm to 25 sqmm 3.5/4 core |
| 122 | (c) 50 sqmm to 120 sqmm 3.5 core |
| 123 | (d) 185 sqmm to 300sqmm 3.5 core |
| 124 | GI tubing 'Light' grade with all fittings for cable protection fixed on poles/walls/laid under roads crossing etc and made good the disturbed surfaces/area for following sizes of pipes complete all as specified and directed by Engineer-in-Charge.[a] 40 mm Bore |
| 125 | (b) 50 mm Bore |
| 126 | (c) 80 mm bore |
| 127 | (d) 100 mm bore |
| 128 | M&L for boing of holes under road, pavement and hard standing by trenchess techonology using ultra sound tecnique and necessary machine including HDPE pipe of 110mm dia suitable for 0.4 mpa working pressure complete all as specified and directed by Engineer-in-Charge. |
| 129 | M/L for MCCB 4 pole,415 volts Adjustable type including disconnecting the incoming/outgoing cable connections and re-connecting with suitable aluminum lugs/ferruls including extended terminals etc. after taking out the existing unserviceable and making good the disturbed surface for following capacity complete all as specified and directed by Engineer-in-Charge.[a] 400 Amps with breaking capacity 36 KA |
| 130 | [b] 200 Amps with breaking capacity 36 KA |
| 131 | M/L for MCCB 3pole, 415 volts fixed type including disconnecting the incoming/outgoing cable connections and re-connecting with suitable aluminum lugs/ferruls including extended terminals etc. after taking out the existing unserviceable and making good the disturbed surface for following capacity complete all as specified and directed by Engineer-in-Charge.[a] 32 to 100 Amps with breaking capacity 16 KA |
| 132 | [b] 160 Amps with breaking capacity 36 KA |
| 133 | ( c) 200 Amps with breaking capacity 36 KA |
| 134 | M/L for earthing complete with galvanized steel earth plate electrode 600X600X6mm thick buried directly in ground (earth pit not less than 2.25m deep below normal ground level) with top edge of the plate not less than 1.5M below normal ground level connected to GI earth strip of size 25 x 3 by means of nuts, bolts, check nuts and washer of GI steel and connecting to testing point including provision of test point and all as shown in electrical plate No. 3 of SSR Pt I. The work is inclusive of necessary earth work and PCC chamber in type CI (1:2:4) with 8 TMT bar reinforcement both ways at 140 mm centre to centre complete all as specified and directed by Engineer-in-Charge.Note:- GI earth lead beyond 7.5M shall be measured and paid separately Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Tender Published
Tender notice published.
CompletedBid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 19 daysBid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 21 daysTender Documents
Download All (ZIP) ↓We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender